PROVISIONAL DATA SHET

DR. FIXIT PIDICRETE CF 351


High Range Water reducing and retarding admixture for High Performance Concrete

Dr. Fixit Pidicrete CF 351 is a superplasticising DOSAGE:


admixture design with specially formulated polymers Dosage range of Dr. Fixit Pidicrete CF 351 will be
and surfactants to produce high performance concrete. 200 ml to 600 ml per bag of cement.
It also imparts the cohesiveness to concrete mix for • Optimum dosage should be determined by
easy placing and better surface finish. doing site trial mixes. Dosage may go above

CONCRETE ADMIXTURES
maximum limit for High Performance Concrete
and shall be determined by site trial mix.
SPECIFICATION : IS: 9103-1999 and ASTM-C-494-
86, Type G
COMPATIBILITY:
AREA OF APPLICATION: Dr. Fixit Pidicrete CF 351 is compatible with
all types of cement e.g. OPC, PPC, PSC etc.
Dr. Fixit Pidicrete CF 351 is compatible with
High Performance Concrete all air entraining agent which complies
Self Compactible Concrete wiith IS 9103-2003 and Integral water proofing
Precast Concrete compound which complies with IS 2645- 1978.
If other admixtures are to be used in concrete
containing Dr. Fixit Pidicrete CF 351 they must
FEATURES & BENEFITS:
be dispensed separately.
Water reduction upto 28 % without effecting the
workability.
SAFETY PRECAUTIONS :
Helps in reducing cement content for a required
strength by reducing w/c ratio. Dr. Fixit Pidicrete CF 351 is a non-toxic and
inflammable. When in contact with the skin, it
should be washed with cold water.
Increases workability at a given w/c ratio, resulting
easy placing, and eliminates honeycombing.
TECHNICAL INFORMATION :
High workability for longer periods to allow long
Appearance : Dark Brown Liquid
distance transport of concrete.
Sp.Gravity : 1.220 +/- 0.02
Reduction in shrinkage cracks Chloride content : Nil
Less permeable and hence more durable concrete. pH Value : 7 +/- 1

METHOD OF APPLICATION: STORAGE :


PIDICRETE CF 330

Concrete shall be mixed with 50-70% of the • Keep the liquid above freezing temperature.
mixing water(based on mix design by weight). • If the product has frozen, thaw it at room
The correct quantity of Dr. Fixit Pidicrete CF temperature(25°C) and agitate to completely
351 should be measured with recommended reconstitute it in the original form.
dispenser and should be added to the concrete with • Store under cover ; protect from direct sunlight.
remaining 30% mixing water and allow to mix it for
recommended mixing time. • Failure to comply with recommended storage
CC-DF-CF-330-FLR-ENG-

condition may result in premature deterioration of


Dr. Fixit Pidicrete CF 351 should not be added in the product and packaging.
dry mixes under any circumstances

PACKING: 250 & Tanker


10/08

Supply Tanker supply in


litres / kgs
Pidilite Industries Limited
Construction Chemicals Division & its agents has been provided in good faith & meant to serve only as a general
guideline during usage. Users are advised to carry out tests & take trials to ensure on
Ramkrishna Mandir Road Post Box No. 17411 the suitability of products meeting their requirement prior to full scale usage of our
Andheri (E) Mumbai 400059 INDIA products. Since the correct identification of the problems, quality of other materials
Tel +91-22-2835 7000 Fax +91-22-2835 7008 used and on-site workmanship are factors beyond our control, there are no
expressed or implied guarantee / warranty as to the results obtained. The Company
website www.doctor-fixit.com E-mail drfixit@pidilite.com does not assume any liabiltiy or any consequentialdamage for unsatisfactory
Disclaimer: The product information & application details given by the company
results,arisingfrom the use of our products.

You might also like