You are on page 1of 7

Inside Are

nom OD wt ID class eqiuv pr class sf


4.00 4.80 0.32 4.16 53 350 ###
6.00 6.90 0.34 6.22 53 ###
8.00 9.05 0.36 8.33 53 4.525 ### ###
10.00 11.10 0.38 10.34 53 5.55 ###
12.00 13.20 0.40 12.40 53 6.6 0.55 ###
14.00 15.30 0.42 14.46 53 ###
16.00 17.40 0.43 16.54 53 ###
18.00 19.50 0.44 18.62 53 ###
20.00 21.60 0.45 20.70 53 ###
24.00 25.80 0.47 24.86 53 ###
36.00 38.30 0.58 37.14 53 ###

nom OD wt ID class
4.00 4.80 0.26 4.28 51
6.00 6.90 0.28 6.34 51
8.00 9.05 0.30 8.45 51
10.00 11.10 0.32 10.46 51
12.00 13.20 0.34 12.52 51
14.00 15.30 0.36 14.58 51
16.00 17.40 0.37 16.66 51
18.00 19.5 0.38 18.74 51.00
20.00 21.60 0.39 20.82 51
24.00 25.82 0.41 25.00 51
36.00 38.30 0.48 37.34 51

check pipe class

nom OD wt ID class
4.00 Not Available - 50 350 ?
6.00 6.90 0.25 6.40 50
8.00 9.05 0.27 8.51 50
10.00 11.10 0.29 10.52 50
12.00 13.20 0.31 12.58 50
14.00 15.30 0.33 14.64 50
16.00 17.40 0.35 16.70 50 8.7
18.00 19.50 0.35 18.80 50
20.00 21.60 0.36 20.88 50
24.00 25.82 0.38 25.06 50
36.00 38.30 0.43 37.44 50
http://www.acipco.com/adip/pipe/pressures-weights/weights-specials.cf
Weight in Po

for P= 150 psi


force 21600 psf
###
###
###
###
###
###
###
###
###
###
###

Wall
Thickness Thickness Per Foot
Size in. Class in. Plain End

18 50 0.35 64.4
pressures-weights/weights-specials.cfm
Weight in Pounds
FASTITE MECHANICAL

Per Per
Per FootJOINT
Nominal** JOINT*
Per Foot Nominal**
Inc. Bell Length Inc. Bell Length

68 1365 - -
IPS sizes

SDR Nom OD ID wall thickness SDR (Check)

11
160 psi
10.75 8.7960 0.9770 11.00
10.75 8.7178 1.01608 10.58 The WALL thickness is calculated as the minimum WAL
10.75 8.6788 1.03562 10.38 Driscopipe - The WALL thickness is calculated as the mi
1.06

17 16.00 14.1200 0.94 17.02


100 psi
36 31.7640 2.1180 17.00
adder 36 31.5946 2.20272 16.34 The WALL thickness is calculated as the minimum WAL
0% 10 10.75 9.4860 0.6320 17.01
4% 10.75 9.4354 0.65728 16.36 The WALL thickness is calculated as the minimum WAL
6% 10.75 9.4102 0.66992 16.05 Driscopipe - The WALL thickness is calculated as the mi
1.06
0% 8 8.63 7.6110 0.5070 17.01
4% 8 8.63 7.5704 0.52728 16.36 The WALL thickness is calculated as the minimum WAL
6% 8 8.63 7.5502 0.53742 16.05 Driscopipe - The WALL thickness is calculated as the mi
0% 6 6.63 5.8450 0.3900 16.99
4% 6 6.63 5.8138 0.4056 16.33 The WALL thickness is calculated as the minimum WAL
6% 6 6.63 5.7982 0.4134 16.03 Driscopipe - The WALL thickness is calculated as the mi

12 12.75 11.1600 0.795 16.04 Driscopipe - The WALL thickness is calculated as the mi
0.75
0% 2 2.38 2.0950 0.1400 16.96
4% 2.38 2.0838 0.1456 16.31 The WALL thickness is calculated as the minimum WAL
6% 2.38 2.0782 0.1484 16.00 Driscopipe - The WALL thickness is calculated as the mi

0% 14 14.00 12.3520 0.8240 16.99


4% 14.00 12.2861 0.85696 16.34 The WALL thickness is calculated as the minimum WAL
6% 14.00 12.2531 0.87344 16.03 Driscopipe - The WALL thickness is calculated as the mi

0% 16 16.00 14.1180 0.9410 17.00


4% 16.00 14.0427 0.97864 16.35 The WALL thickness is calculated as the minimum WAL
6% 16.00 14.0051 0.99746 16.04 Driscopipe - The WALL thickness is calculated as the mi

0% 18 18.00 15.8820 1.0590 17.00


4% 18.00 15.7973 1.10136 16.34 The WALL thickness is calculated as the minimum WAL
6% 18.00 15.7549 1.12254 16.04 Driscopipe - The WALL thickness is calculated as the mi

0% 24 24.00 21.1760 1.4120 17.00


4% 24.00 21.0630 1.46848 16.34 The WALL thickness is calculated as the minimum WAL
6% 24.00 21.0066 1.49672 16.04 Driscopipe - The WALL thickness is calculated as the mi

21 36 32.5720 1.714 21.00


36 32.4349 1.78256 20.20 The WALL thickness is calculated as the minimum WAL

driscopipe formula to find id to use for fluid flow:

id = od - 2,12 * (od/dr)
for 10" sdr 17 pipe this gives:
###

0% 36 36.00 31.7640 2.1180 17.00


4% 36.00 31.5946 2.20272 16.34 The WALL thickness is calculated as the minimum WAL
6% 36.00 31.5098 2.24508 16.04 Driscopipe - The WALL thickness is calculated as the mi

Pipe weights are calculated in accordance with PPI TR-7. Average inside diameter calculated using nominal Pressure Ratings are for water
OD and minimum wall plus 6% for use in estimating fluid flows. Actual ID will vary. When designing components service temperature, rat
to fit the pipe ID, refer to pipe dimensions and tolerances in applicable pipe specifications. Manual for Chemical and Environmental Consid

17
100 psi
2 2.375 2.0950 0.1400 16.96
2.375 2.0838 0.1456 16.31 The WALL thickness is calculated as the minimum WAL
2.375 2.0782 0.1484 16.00 Driscopipe - The WALL thickness is calculated as the mi
1.06

3 3.5 3.0880 0.2060 16.99


3.5 3.0715 0.21424 16.34 The WALL thickness is calculated as the minimum WAL
3.5 3.0633 0.21836 16.03 Driscopipe - The WALL thickness is calculated as the mi
1.06
DIPS sizes:

ss is calculated as the minimum WALL plus 4%, rounded to the nearest 0.001 inch.
ALL thickness is calculated as the minimum WALL plus 6%, rounded to the nearest 0.001 inch.

ss is calculated as the minimum WALL plus 4%, rounded to the nearest 0.001 inch.

ss is calculated as the minimum WALL plus 4%, rounded to the nearest 0.001 inch.
ALL thickness is calculated as the minimum WALL plus 6%, rounded to the nearest 0.001 inch.

ss is calculated as the minimum WALL plus 4%, rounded to the nearest 0.001 inch.
ALL thickness is calculated as the minimum WALL plus 6%, rounded to the nearest 0.001 inch.

ss is calculated as the minimum WALL plus 4%, rounded to the nearest 0.001 inch.
ALL thickness is calculated as the minimum WALL plus 6%, rounded to the nearest 0.001 inch.

ALL thickness is calculated as the minimum WALL plus 6%, rounded to the nearest 0.001 inch.

ss is calculated as the minimum WALL plus 4%, rounded to the nearest 0.001 inch.
ALL thickness is calculated as the minimum WALL plus 6%, rounded to the nearest 0.001 inch.

ss is calculated as the minimum WALL plus 4%, rounded to the nearest 0.001 inch.
ALL thickness is calculated as the minimum WALL plus 6%, rounded to the nearest 0.001 inch.

ss is calculated as the minimum WALL plus 4%, rounded to the nearest 0.001 inch.
ALL thickness is calculated as the minimum WALL plus 6%, rounded to the nearest 0.001 inch.

ss is calculated as the minimum WALL plus 4%, rounded to the nearest 0.001 inch.
ALL thickness is calculated as the minimum WALL plus 6%, rounded to the nearest 0.001 inch.

ss is calculated as the minimum WALL plus 4%, rounded to the nearest 0.001 inch.
ALL thickness is calculated as the minimum WALL plus 6%, rounded to the nearest 0.001 inch.
ss is calculated as the minimum WALL plus 4%, rounded to the nearest 0.001 inch.

ss is calculated as the minimum WALL plus 4%, rounded to the nearest 0.001 inch.
ALL thickness is calculated as the minimum WALL plus 6%, rounded to the nearest 0.001 inch.

ominal Pressure Ratings are for water at 73.4 °F. For other fluid and
g components service temperature, ratings may differ. Refer to Engineering
r Chemical and Environmental Considerations.

ss is calculated as the minimum WALL plus 4%, rounded to the nearest 0.001 inch.
ALL thickness is calculated as the minimum WALL plus 6%, rounded to the nearest 0.001 inch.

ss is calculated as the minimum WALL plus 4%, rounded to the nearest 0.001 inch.
ALL thickness is calculated as the minimum WALL plus 6%, rounded to the nearest 0.001 inch.