Professional Documents
Culture Documents
GERMANY RUSSIA
Prysmian Kabel und Systeme GmbH Alexey Glushkov
Austrasse 99 Representative for marine and offshore
D-96465 Neustadt bei Coburg, Germany projects in Russia and the CIS countries
Tel. +49 9568 93 2697 V.O., line 22, building 3
Fax +49 9568 93 2527 199106, St. Petersburg
T: +7 (812) 932 20 72
ITALY F: +7 (812) 640 01 91
Prysmian Cavi e Sistemi Energia Srl M: +7 960 287 33 69
Via Sarca 222, 20126 Milan, Italy
Tel. +39 02 64491 Prysmian Russia
Fax +39 02 6449 2931 125167, Russia, Moscow,
4th Str. Vosmogo Marta, 6a, build.1
NORWAY Tel: +7(495) 933 70 36
Draka Norsk Kabel AS Fax: +7(495) 933 70 35
P.O. BOX 369, N-3001 Drammen
Tel. +47 64 915 713 Prysmian Russia
Fax +47 64 915 714 125167, Россия, Москва,
4-я улица Восьмого Марта,
6А, строение 1
Тел: +7(495) 933 70 36
Факс: +7(495) 933 70 35
Marine Cables
STURMAN OY / HANNUN TASAPAINO OY / 09-2011 / 1.000
HEAD OFFICE
Prysmian Cables and Systems - Viale Sarca 222, 20126 Milano, Italy - tel. +39 02 6449 1, fax +39 02 6449 2931 - www.prysmian.com
About us Marine Cables
Prysmian Energy Cables and Systems is a global solutions In Finland there are two production facilities, the Pikkala
provider, offering a wide range of integrated solutions, cable factory and the Oulu cable factory. The Pikkala factory
such as cable systems, system design and engineering, is situated in Kirkkonummi, about 40 km west of Helsinki
project management, installation and post-sale services. along the coast. Production consists of marine cables,
heating cables and low, medium and high voltage cables
Prysmian concentrates on continuous product innovation as well as submarine cables. The main customer groups are
and on achieving a competitive edge by focusing on shipyards, installers, wholesalers, contractors, industry and
research and development. This is done through Prysmian’s power utilities.
own R&D centres and by co-operating with universities,
scientific institutions and above all, our customers. The Oulu factory is situated in the city of Oulu, about 800 km
Prysmian’s world-wide organisation makes and delivers north of Helsinki by the northern end of the Gulf of Bothnia.
advanced technological solutions to customers anywhere The main products there are various telecom cables and
in the world. house wiring cables.
Martin Pekuri Olli Anttonen Katrine Dawson Jorma Ikäheimonen Satu Karmavalo
+358 10 77 55 605 +358 10 77 55 603 +358 10 77 55 606 +358 10 77 55 496 +358 10 77 55 828
martin.pekuri@ olli.anttonen@ katrine.dawson@ jorma.ikaheimonen@ satu.karmavalo@
prysmian.com prysmian.com prysmian.com prysmian.com prysmian.com
Seija Kurtén Timo Pölkki Vesa Riitaoja Susanne Welander Alexey Glushkov
+358 10 77 55 604 +358 10 77 55 876 +358 10 77 55 472 +358 10 77 55 618 +796 02 873 369
seija.kurten@ timo.polkki@ vesa.riitaoja@ susanne.welander@ prysma@yandex.ru
prysmian.com prysmian.com prysmian.com prysmian.com
General 4
HFX-ISOSA/Cu 250 V
Individually Screened Instrumentation and
Telecommunication Cable 16
4
4
Vertical flame propagation test 300 ± 25 Cable sample
IEC 60332-1-2
50
1200 ± 25
475 540 Max. length of downward
600 ± 25550 ± 25
limit of charred surface
150
Metal Wire Ties
4000 ± 100
Centre Line of Burner
Air Inlet
(800 ± 20) x (400 ± 10) 500 ± 5
600 ± 5
400 ± 5
Figure 2.
Support Arm
70 ± 10
45
Temperature 750 °C
Flow Rates (1 bar, 20 °C):
Figure 3. Air 80 ± 5 Propane 5 ± 0,25
5
Power and Marine Cables
Control Cables
LM-HF
0,6/1(1,2) kV
Unarmoured
(TEMA) Power and Control
Cable
Design >
Conductor
Annealed stranded plain copper
- round 1,5 to 16 mm2
- round compacted 25 to 240 mm2
- sector shaped in 3-4 cores 35 to 240 mm2
> Insulation
Extruded XLPE
- See page 33 for core identification colours
> Sheath
Extruded black halogen free polyolefine, SHF1
> Installation information and electrical data on pages 30-35
Standards >
Construction
IEC 60092-353 and IEC 60092-350
> Materials
IEC 60228 Class 2 (conductor)
IEC 60092-351 (insulation)
IEC 60092-359 (sheath)
> Flame Retardance
IEC 60332-3-22 (cat A) and IEC 60332-1-2
> Halogen Free Properties
IEC 60754-1 and -2
> Low Smoke Emission
IEC 61034-1 and -2
> Tests
IEC 60092-353
> Choice and Installation
IEC 60092-352
> Maximum conductor temperature +90 °C
6
Conductor Cable Bending
Size Diameter/Height Width Diameter Weight Radius
approx. approx. approx. approx. min.
(n x mm2) or (n G mm2) (mm) (mm) (mm) (kg/km) (mm)
POWER CABLES
1x16 5,0 9,0 200 70
1x25 5,8 – 10,5 290 85
1x35 6,9 – 11,5 385 90
1x50 8,0 – 13,0 510 100
1x70 9,7 – 15,0 720 120
1x95 11,3 – 16,5 970 130
1x120 12,7 – 18,5 1210 150
1x150 14,1 – 20,5 1490 160
1x185 15,7 – 23,0 1840 180
1x240 18,1 – 25,5 2390 200
1x300 20,2 29,0 3100 230
2x1,5 1,6 – 8,5 80 35
2x2,5 2,0 – 9,5 105 40
3x1,5 3G1,5 1,6 – 9,0 100 40
3x2,5 3G2,5 2,0 – 10,5 140 45
3x4 3G4 2,6 – 11,5 200 45
3x6 3G6 3,1 – 12,5 260 50
3x10 4,0 – 14,5 420 60
3x16 5,0 – 17,5 620 70
3x25 5,8 – 20,0 940 80
3x35 5,6 9,2 20,5 1170 160
3x50 6,5 10,7 23,0 1550 185
3x70 7,9 12,8 27,0 2200 215
3x95 9,3 15,1 31,0 2950 250
3x120 10,5 17,0 34,0 3700 270
3x150 11,6 18,9 38,0 4600 300
4x1,5 4G1,5 1,6 – 10,0 130 40
4x2,5 4G2,5 2,0 – 11,0 175 45
4x4 4G4 2,6 – 13,0 260 55
4x6 4G6 3,1 – 14,0 340 55
4x10 4G10 4,0 – 16,5 550 65
4x16 4G16 5,0 – 19,0 800 75
4x25 4G25 5,8 – 22,5 1200 90
4x35 4G35 6,2 8,6 23,0 1550 185
4x50 4G50 7,2 9,9 26,5 2050 210
4x70 4G70 8,6 12,0 31,0 2900 250
4x95 4G95 10,2 14,1 35,0 3900 280
4x120 4G120 11,5 15,8 39,0 4900 310
5x1,5 5G1,5 1,6 – 11,0 155 45
5x2,5 5G2,5 2,0 – 12,5 215 50
– 5G6 3,1 – 15,5 430 65
– 5G10 4,0 – 18,0 660 75
– 5G16 5,0 – 21,0 1000 85
– 5G25 5,8 – 25,0 1500 100
CONTROL CABLES
7x1,5 1,6 – 13,0 220 55
12x1,5 1,6 – 16,0 325 65
19x1,5 1,6 – 19,0 480 75
27x1,5 1,6 – 22,5 670 90
7x2,5 2,0 – 14,5 305 60
12x2,5 2,0 – 18,0 460 75
19x2,5 2,0 – 21,0 690 85
CLASS 5 CONDUCTOR
1x50 9,9 – 15,0 550 90
1x70 11,0 – 17,0 770 100
1x95 13,5 – 19,0 1000 115
1x120 15,2 – 21,0 1250 125
1x150 17,2 – 24,0 1550 145
1x185 18,9 – 26,0 1880 155
1x240 21,8 – 30,0 2450 180
7
Power and Marine Cables
Control Cables
Design >
Conductor
Annealed stranded plain copper
- round 1,5 to 16 mm2
- round compacted 25 to 240 mm2
- sector shaped in 3-4 cores 35 to 240 mm2
> Insulation
Extruded XLPE
- See page 33 for core identification colours
> Armour
Braid of copper wires designed to act as collective screen
> Sheath
Extruded black halogen free polyolefine, SHF1
> Installation information and electrical data on pages 30-35
Standards >
Construction
IEC 60092-353 and IEC 60092-350
> Materials
IEC 60228 Class 2 (conductor)
IEC 60092-351 (insulation)
IEC 60092-359 (sheath)
> Flame Retardance
IEC 60332-3-22 (cat A) and IEC 60332-1-2
> Halogen Free Properties
IEC 60754-1 and -2
> Low Smoke Emission
IEC 61034-1 and -2
> Tests
IEC 60092-353
> Choice and Installation
IEC 60092-352
> Maximum conductor temperature +90 °C
8
Conductor Diameter Cable Bending
Size Diameter/Height Width over Braid Diameter Weight Radius
approx. approx. approx. approx. approx. min.
(n x mm2) or (n G mm2) (mm) (mm) (mm) (mm) (kg/km) (mm)
POWER CABLES
1x16 5,0 – 8,5 11,0 270 90
1x25 5,8 – 9,5 12,5 365 100
1x35 6,8 – 10,5 13,5 470 110
1x50 7,9 – 12,0 15,0 620 120
1x70 9,6 – 14,0 17,5 850 140
1x95 11,3 – 16,0 19,0 1130 150
1x120 12,7 – 17,5 21,0 1400 170
1x150 14,1 – 19,5 23,0 1700 180
1x185 15,7 – 21,5 25,0 2070 200
1x240 18,1 – 24,0 28,0 2650 220
2x1,5 1,6 – 7,5 10,0 130 60
2x2,5 2,0 – 8,5 11,0 160 65
3x1,5 3G1,5 1,6 – 8,0 10,5 155 65
3x2,5 3G2,5 2,0 – 9,0 11,5 195 70
3x4 2,6 – 10,0 13,0 270 80
3x6 3,1 – 11,0 14,0 320 85
3x10 4,0 – 13,5 16,5 520 100
3x16 5,0 – 16,0 19,0 740 115
3x25 5,8 – 18,5 22,0 1050 135
3x35 5,6 9,2 19,0 23,0 1350 185
3x50 6,5 10,7 21,5 25,5 1750 205
3x70 7,9 12,8 25,0 29,0 2400 230
3x95 9,3 15,1 28,0 33,0 3200 260
3x120 10,5 17,0 31,5 36,5 4100 290
3x150 11,6 18,9 35,0 41,0 5000 330
4x1,5 4G1,5 1,6 – 8,5 11,0 180 70
4x2,5 4G2,5 2,0 – 10,0 12,5 250 80
4x4 4G4 2,6 – 11,5 14,0 320 85
4x6 4G6 3,1 – 13,0 16,0 450 95
4x10 4G10 4,0 – 15,5 18,5 670 115
4x16 4G16 5,0 – 17,5 21,0 940 130
4x25 4G25 5,8 – 20,5 24,0 1350 145
4x35 4G35 6,2 8,6 21,5 25,5 1750 200
4x50 4G50 7,2 9,9 24,5 29,0 2300 230
4x70 4G70 8,6 12,0 28,0 33,0 3200 265
4x95 4G95 10,2 14,1 32,0 37,0 4300 300
4x120 4G120 11,5 15,8 36,0 41,0 5300 330
5x1,5 5G1,5 1,6 – 9,5 12,0 220 75
5x2,5 5G2,5 2,0 – 11,0 13,5 290 85
CONTROL CABLES
7x1,5 1,6 – 11,5 14,5 300 105
12x1,5 1,6 – 14,5 17,5 470 110
19x1,5 1,6 – 17,0 20,5 650 125
27x1,5 1,6 – 21,0 24,5 870 145
7x2,5 2,0 – 13,5 16,5 430 100
12x2,5 2,0 – 16,5 20,0 620 120
19x2,5 2,0 – 19,5 23,0 900 140
CLASS 5 CONDUCTOR
1x50 9,9 – 15,0 17,5 700 105
1x70 11,0 – 17,0 19,0 920 115
1x95 13,5 – 19,0 21,0 1170 125
1x120 15,2 – 21,0 23,5 1450 140
1x150 17,2 – 24,0 26,0 1550 155
1x185 18,9 – 26,0 28,5 1770 170
1x240 21,8 – 30,0 32,0 2700 190
9
Power Marine Cables
Cables
Design >
Conductor
Annealed stranded plain copper
- round compacted 25 to 240 mm2
> Insulation
Extruded XLPE
- See page 33 for core identification colours
- Plastic coated copper tape under the braid in 3-core cables
> Armour
Braid of copper wires
> Inner covering
Extruded halogen free polyolefine in 3-core cables
> Sheath
Extruded black halogen free polyolefine, SHF1
Standards >
Construction
IEC 60092-353 and IEC 60092-350
> Materials
IEC 60228 Class 2 (conductor)
IEC 60092-351 (insulation)
IEC 60092-359 (sheath)
> Flame Retardance
IEC 60332-3-22 (cat A) and IEC 60332-1-2
> Halogen Free Properties
IEC 60754-1 and -2
> Low Smoke Emission
IEC 61034-1 and -2
> Tests
IEC 60092-353
> Choice and Installation
IEC 60092-352
> Maximum conductor temperature +90 °C
10
Conductor Diameter Cable Bending
Size Diameter over Braid Diameter Weight Radius
approx. approx. approx. approx. min.
(n x mm2) (mm) (mm) (mm) (kg/km) (mm)
LSM-HF 3 kV
1x185 15,7 23 27 2100 330
1x240 18,1 25 29 2700 350
LSM-HF 3 kV EMC
3x 95/35 11,3 38 44 4700 400
3x120/40 12,7 42 48 5700 430
3x150/40 14,1 46 52 6700 470
3x 95+3G16 11,3 36 42 4200 380
3x120+3G25 12,7 39 45 5200 410
11
Instrumentation Marine Cables
Cables
LJST-HF
150/250 (300) V
Armoured
(TEMA-TA) Instrumentation
and
Telecommunication
Cable
Design >
Conductor
Stranded annealed plain copper conductor
> Insulation
Extruded XLPE
> Pair
White and blue cores are twisted to pair (see page 33)
> Armour (common screen)
Combined electrical and mechanical protection
Braid of copper wires
- Drain conductor
> Sheath
Extruded grey halogen free polyolefine, SHF1
Standards >
Construction
IEC 60092-376 and IEC 60092-350
> Materials
IEC 60228 Class 2 (conductor)
IEC 60092-351 (insulation)
IEC 60092-359 (sheath)
> Flame Retardance
IEC 60332-3-22 (cat A) and IEC 60332-1-2
> Halogen Free Properties
IEC 60754-1 and -2
> Low Smoke Emission
IEC 61034-1 and -2
> Tests
IEC 60092-376
> Maximum conductor temperature +90 °C
12
Conductor Screen Cable Bending
Size Diameter Diameter Diameter Weight Radius
approx. approx. approx. approx. min.
(n x 2 x mm2) (mm) (mm) (mm) (kg/km) (mm)
Conductor Insulation
Variable Value
resistance at resistance
n x 2 x mm2 20 ˚C max W/km min MW x km
Mutual capacitance single pair 60 nF/km
Troitsky Bridge
Courtesy of Admiralty Shipyard
13
Instrumentation Marine Cables
Cables
LJT-HF Screened
150/250 (300) V
(TEMA-TO) Instrumentation
and
Telecommunication
Cable
Design >
Conductor
Stranded annealed plain copper conductor
> Insulation
Extruded XLPE
- See page 33 for core identification colours and numbers
> Pair
White and blue cores are twisted to pair (see page 33)
> Common screen
Plastic coated aluminium tape
- Tinned copper drain wire
- Coverage 100 %
> Sheath
Extruded grey halogen free polyolefine, SHF1
Standards >
Construction
IEC 60092-376
> Materials
IEC 60228 Class 2 (conductor)
IEC 60092-351 (insulation)
IEC 60092-359 (sheath)
> Flame Retardance
IEC 60332-3-22 (cat A) and IEC 60332-1-2
> Halogen Free Properties
IEC 60754-1 and -2
> Low Smoke Emission
IEC 61034-1 and -2
> Tests
IEC 60092-376
> Maximum conductor temperature +90 °C
14
Conductor Cable Bending
Size Diameter Diameter Weight Radius
approx. approx. approx. min.
(n x 2 x mm2) (mm) (mm) (kg/km) (mm)
15
Instrumentation Marine Cables
Cables
HFX-ISOSA/Cu Individually
250 V
(TEMA-TIOA) Screened
Instrumentation
and
Telecommunication
Cable
Design >
Conductor
Stranded annealed plain copper conductor
> Insulation
Extruded XLPE
- Number identification
> Pair
Black and blue cores are twisted to pair
> Sreen
Individual and collective screen of plastic laminated aluminium tape
- tinned copper drain wires
> Armour
Braid of plain copper wires
> Sheath
Extruded orange halogen free polyolefine, SHF1
Standards >
Construction
IEC 60092-375, -376 and 92-3
> Materials
IEC 60228 Class 2 (conductor)
IEC 60092-351 (insulation)
IEC 60092-359 (sheath)
> Flame Retardance
IEC 60332-3-22 (cat A) and IEC 60332-1-2
> Halogen Free Properties
IEC 60754-1 and -2
> Low Smoke Emission
IEC 61034-1 and -2
> Tests
IEC 60092-375, -376
> Maximum conductor temperature +90 °C
16
Conductor Cable Bending
Size Resistance Diameter Diameter Weight Radius
max. approx. max. approx. min.
(n x 2 x mm2) (Ω/km) (mm) (mm) (kg/km) (mm)
250 V
2 x 2 x 0,75 26,0 1,1 13,6 170 109
4 x 2 x 0,75 26,0 1,1 17,0 300 136
7 x 2 x 0,75 26,0 1,1 20,1 420 161
10 x 2 x 0,75 26,0 1,1 24,9 630 199
14 x 2 x 0,75 26,0 1,1 27,1 760 217
19 x 2 x 0,75 26,0 1,1 30,1 1000 241
24 x 2 x 0,75 26,0 1,1 34,1 1190 273
17
Instrumentation Marine Cables
Cables
SIENOPYR-FR Bus-Cable
PROFIBUS
M-02Y(ST)CHX
100V
(TEMA-
PROFIBUS)
Design >
Conductor
7 bare copper wires,
E-Cu58 F21 to DIN 40500 part 4
cross section: 0,35 mm2
(AWG 22 = 0,325 mm2)
> Insulation
Polyethylene foam (cellular HDPE)
> Core identification
- a core: red
- b core: green
> Laying
Laying of the both copper cores with two blind cores
> Core assembly wrapping
Nonwoven plastic textile band
> Multi layer screen
1. layer: laminated aluminium foil,
2. layer: tinned copper wire braid
> Inner Sheath according VDE 0207 part 24
Halogen free polymer (HM4)
diameter: 8 mm (nominal)
> Outer Sheath according IEC 60092-359
Halogen free, cross-linked polymer
Colour: black
Standards >
Ozone
DIN VDE 0472 Part 805, Test B
> Fire retardance
IEC 60332-3-24 (cat C)
> Corrosivity of combustion gasses
IEC 60754-2
> Smoke density
IEC 61034
> Resistance to chemicals (Test to VG 95218 Part 2):
- diesel fuel
- oils
- hydraulic fluids
- solvent cleaning agents
- de-ionozed water
- de-ionized water with 3,5 % NaCl
> Maximum conductor temperature +80 °C
18
Transmission characteristics >
Voltage
100 V
> Conductor resisitance 1 km loop at 20 ˚C
max. 110 W/km
> Characteristic impedance
at 3 to 20 MHz 150 ± 15 W
at 38,4 kHz 185 ± 18,5 W
at 9,6 kHz 250 ± 25 W
> Wave attenuation
at 16 MHz max. 45 dB/km
at 4 MHz max. 22 dB/km
at 38,4 kHz max. 5 dB/km
at 9,6 kHz max. 3 dB/km
> Mutual capacitance at 800 Hz
max. 30 nF/km
> Insulation resistance at 20 ˚C
min. 16 000 MWkm
> Outer sheath surface resistance min 109 W
Photos
Martin Pekuri
19
Fire Resistant Marine Cables
Cables
LM-FRHF
0,6/1 (1,2) kV
Unarmoured Fire
(TEMA-FR) Resistant Power and
Control Cable
Design >
Conductor
Annealed stranded plain copper
- round 1,5 to 16 mm2
- round compacted 25 to 240 mm2
- sector shaped in 3-4 cores 35 to 240 mm2
> Insulation
Mica tape with overlap as fire resistant layer
Extruded HF90
- see page 33 for core identification colours
> Sheath
Extruded orange halogen free polyolefine, SHF1
> Installation information and electrical data on pages 30-35
Standards >
Construction
IEC 60092-353 and IEC 60092-350
> Materials
IEC 60228 Class 2 (conductor)
IEC 60092-351 (insulation)
IEC 60092-359 (sheath)
> Fire Resistance
IEC 60331-1 or IEC 60331-2
> Flame Retardance
IEC 60332-3-22 (cat A) and IEC 60332-1-2
> Halogen Free Properties
IEC 60754-1 and -2
> Low Smoke Emission
IEC 61034-1 and -2
> Tests
IEC 60092-353
> Choice and Installation
IEC 60092-352
> Maximum conductor temperature +90 °C
20
Conductor Cable Bending
Size Diameter/Height Width Diameter Weight Radius
approx. approx. approx. approx. min.
(n x mm2) or (n G mm2) (mm) (mm) (mm) (kg/km) (mm)
POWER CABLES
2x1,5 1,6 – 10,0 90 40
2x2,5 2,0 – 11,0 120 45
3x1,5 3G1,5 1,6 – 10,5 110 45
3x2,5 3G2,5 2,0 – 12,0 150 50
3x6 3,1 – 14,5 280 60
3x10 4,0 – 16,5 450 65
3x16 5,0 – 18,5 650 75
3x25 5,8 – 22,5 970 130
3x35 6,8 – 25,0 1230 150
3x50 6,5 10,7 24,5 1600 195
3x70 7,9 12,8 28,0 2200 225
3x95 9,3 15,1 32,0 3000 255
3x120 10,5 17,0 35,0 3750 280
3x150 11,6 18,9 39,0 4600 310
4x1,5 4G1,5 1,6 – 11,5 140 50
4x2,5 4G2,5 2,0 – 13,0 190 55
CONTROL CABLES
5x1,5 1,6 – 12,5 170 50
7x1,5 1,6 – 15,0 250 60
12x1,5 1,6 – 18,0 370 75
19x1,5 1,6 – 21,0 550 85
27x1,5 1,6 – 26,0 770 160
5x2,5 2,0 - 14,0 240 55
7x2,5 2,0 – 16,0 330 65
12x2,5 2,0 – 20,0 520 80
19x2,5 2,0 – 24,0 770 150
Stril Mermaid
Courtesy of Flekkefjord Elektro AS
21
Fire Resistant Marine Cables
Cables
LSM-FRHF
0,6/1 (1,2) kV
Armoured Fire
(TEMA-AFR) Resistant Power and
Control Cable
Design >
Conductor
Annealed stranded plain copper
- round 1,5 to 16 mm2
- round compacted 25 to 240 mm2
- sector shaped in 3-4 cores 35 to 240 mm2
> Insulation
Mica tape with overlap as fire resistant layer
Extruded HF90
- See page 33 for core identification colours
> Armour
Braid of copper wires designed to act as collective screen
> Sheath
Extruded orange halogen free polyolefine, SHF1
> Installation information and electrical data on pages 30-35
Standards >
Construction
IEC 60092-353 and IEC 60092-350
> Materials
IEC 60228 Class 2 (conductor)
IEC 60092-351 (insulation)
IEC 60092-359 (sheath)
> Fire Resistance
IEC 60331-1 or IEC 60331-2
> Flame Retardance
IEC 60332-3-22 (cat A) and IEC 60332-1-2
> Halogen Free Properties
IEC 60754-1 and -2
> Low Smoke Emission
IEC 61034-1 and -2
> Tests
IEC 60092-353
> Choice and Installation
IEC 60092-352
> Maximum conductor temperature +90 °C
22
Conductor Diameter Cable Bending
Size Diameter/Height Width over Braid Diameter Weight Radius
approx. approx. approx. approx. approx. min.
(n x mm2) or (n G mm2) (mm) (mm) (mm) (mm) (kg/km) (mm)
POWER CABLES
2x1,5 1,6 – 8,5 11,0 150 65
2x2,5 2,0 – 9,5 12,5 190 75
3x1,5 3G1,5 1,6 – 9,0 11,5 185 70
3x2,5 3G2,5 2,0 – 10,0 13,0 240 80
3x6 3,1 – 13,0 15,0 420 95
3x10 4,0 – 15,0 18,0 610 110
3x16 5,0 – 17,5 20,5 820 125
3x25 5,8 – 20,5 23,5 1150 140
3x35 6,8 – 22,0 26,0 1500 190
3x50 6,5 10,7 22,0 26,5 1900 215
3x70 7,9 12,8 25,5 30,0 2600 240
3x95 9,3 15,1 29,5 34,0 3500 275
3x120 10,5 17,0 32,0 37,0 4300 300
3x150 11,6 18,9 35,5 41,0 5200 330
4x1,5 1,6 – 10,0 13,0 230 75
4x2,5 2,0 – 11,0 14,0 285 85
CONTROL CABLES
5x1,5 5G1,5 1,6 – 11,5 14,0 270 85
7x1,5 1,6 – 14,0 17,0 410 105
12x1,5 1,6 – 17,0 20,0 570 120
19x1,5 1,6 – 19,5 23,0 800 140
27x1,5 1,6 – 24,0 28,0 1100 170
5x2,5 2,0 – 13,0 16,0 390 95
7x2,5 2,0 – 14,5 18,0 490 110
12x2,5 2,0 – 19,0 22,0 740 130
19x2,5 2,0 – 22,0 26,0 1050 160
Courtesy of Courtesy of
the Royal Caribbean Cruise Line the Royal Caribbean Cruise Line
23
Fire Resistant Marine Cables
Cables
SIENOPYR-FR Armoured
FMHXCH FE 120
150/250 (300) V
Fire Resistant
(TEMA-TAFRS) Instrumentation,
Communication and
Control Cable
Design >
Conductor
Stranded annealed plain copper conductor 0,75 mm2
> Insulation
White ceramic HF S95
> Pair
Numbered white cores are twisted to pair (2 pairs is a quad)
> Armour (common screen)
Braid of copper wires
> Sheath
Extruded orange halogen free polyolefine, SHF1
Standards >
Construction
IEC 60092 -376
> Materials
IEC 60228 Class 2 (conductor)
IEC 60092-351 (insulation)
IEC 60092-359 (sheath)
> Fire Resistance
IEC 60331-21 or IEC 60331-31
> Flame Retardance
IEC 60332-3-22 (cat A) and IEC 60332-1-2
> Halogen Free Properties
IEC 60754-1 and -2
> Low Smoke Emission
IEC 61034-1 and -2
> Tests
IEC 60092-376
> Maximum conductor temperature +90 °C
24
Conductor Cable Bending
Size Diameter Diameter Weight Radius
approx. approx. approx. min.
(n x 2 x mm2) (mm) (mm) (kg/km) (mm)
25
Medium Voltage Marine Cables
Cables
MV-FHFX/A
6/10 (12) kV
Armoured Medium
(TEMA-A) Voltage Power Cable
Design >
Conductor
Flexible copper conducter (class 5)
> Conductor screen
Semiconductive tape and extruded compound
> Insulation
Extruded off-white XLPE, nominal thickness 3,4 mm
> Insulation screen
Extruded semiconductive compound
> Metallic Screen
Copper tapes
> Inner Covering
Extruded halogen free compound
> Armour
Braid of copper wires
> Sheath
Extruded red halogen free compound, SHF1
Standards >
Construction
IEC 60092-354 and IEC 60092-350
> Materials
IEC 60228 (conductor)
IEC 60092-351 (insulation)
IEC 60092-359 (sheath)
> Flame Retardance
IEC 60332-3-22 (cat A) and IEC 60332-1-2
> Halogen Free Properties
IEC 60754-1 and -2
> Low Smoke Emission
IEC 61034-1 and -2
> Tests
IEC 60092-354
> Choice and Installation
IEC 60092-352
> Maximum conductor temperature +90 °C
26
Conductor Core Inner Cover Braid Cable
Size Diameter Diameter Thickness Diameter Diameter Weight
approx. approx. approx. approx. approx. approx.
(n x mm2) (mm) (mm) (mm) (mm) (mm) (kg/km)
MV-FHFX/A (FE4H1M1AM1)
1x150 15,6 25,0 1,2 29,0 33,0 2260
MV-FHFX/A (FE4H10M1AM1)
3x35 7,5 17,0 1,2 41,0 46,0 3460
3x50 8,7 18,5 1,2 44,5 50,0 4010
3x70 10,3 20,0 1,2 47,5 53,0 4930
3x95 12,1 21,5 1,2 51,0 57,0 6060
3x120 13,6 23,0 1,2 54,0 60,0 7050
MV-FHFX/A (FE4H1M1AM1)
1x150 369 0,124 0,136 0,156 0,318 0,403
MV-FHFX/A (FE4H10M1AM1)
3x35 104 0,524 0,575 0,658 0,357 0,237
3x50 130 0,387 0,425 0,486 0,341 0,264
3x70 160 0,268 0,294 0,337 0,321 0,300
3x95 194 0,193 0,212 0,242 0,307 0,342
3x120 225 0,153 0,168 0,192 0,296 0,377
1) IEC 60092-352 Table B.4 x 0,95 (see also Tables A.1 - A.8)
Other sizes available upon request
27
Medium Voltage Marine Cables
Cables
MV-FHFX/A
12/20 (24) kV
Armoured Medium
(TEMA-A) Voltage Power Cable
Design >
Conductor
Flexible copper conducter (class 5)
> Conductor screen
Semiconductive tape and extruded compound
> Insulation
Extruded off-white XLPE, nominal thickness 5,5 mm
> Insulation screen
Extruded semiconductive compound
> Metallic Screen
Copper tapes
> Inner Covering
Extruded halogen free compound
> Armour
Braid of copper wires
> Sheath
Extruded red halogen free compound, SHF1
Standards >
Construction
IEC 60092-354 and IEC 60092-350
> Materials
IEC 60228 (conductor)
IEC 60092-351 (insulation)
IEC 60092-359 (sheath)
> Flame Retardance
IEC 60332-3-22 (cat A) and IEC 60332-1-2
> Halogen Free Properties
IEC 60754-1 and -2
> Low Smoke Emission
IEC 61034-1 and -2
> Tests
IEC 60092-354
> Choice and Installation
IEC 60092-352
> Maximum conductor temperature +90 °C
28
Conductor Core Inner Cover Braid Cable
Size Diameter Diameter Thickness Diameter Diameter Weight
approx. approx. approx. approx. approx. approx.
(n x mm2) (mm) (mm) (mm) (mm) (mm) (kg/km)
MV-FHFX/A (FE4H1M1AM1)
1x150 15,6 29,3 1,2 33,4 38,0 2670
MV-FHFX/A (FE4H10M1AM1)
3x35 7,5 21,2 1,2 51,3 58,0 4780
3x50 8,7 22,4 1,2 53,9 60,0 5450
MV-FHFX/A (FE4H1M1AM1)
1x150 369 0,124 0,136 0,156 0,366 0,273
MV-FHFX/A (FE4H10M1AM1)
3x35 104 0,524 0,575 0,658 0,395 0,169
3x50 130 0,387 0,425 0,486 0,376 0,185
1) IEC 60092-352 Table B.4 x 0,95 (see also Tables A.1 - A.8)
Havila Venus
Courtesy of Havyard
29
Technical Marine Cables
Information
Rated Voltage
The rated voltages of cables are expressed as Uo/U(Um) where ≤25 mm 4D
Unarmoured or
unbraided
≥25 mm 6D
Uo the rated voltage between the conductor and earth,
or between the conductor and the metal screen for Metal braid screened Any 6D
which the cable is designed. or armoured
Thermoplastic or
U the rated voltage between the conductors for which thermosetting
with circular Metal wire armoured
the cable is designed. Metal tape armoured Any 6D
copper
Um the highest system voltage for which the cables conductors or metal sheathed
may be used
Composite
polyester/metal
laminate screened Any 8D
Installation Temperature units or collective tape
The minimum installation temperature for thermoplastic sheathed screening
cables is –15 ºC. If, however, the cables are warmed up prior to Thermoplastic or
installation, they can be installed at lower temperatures. thermosetting
with shaped Any Any 8D
Lowest operation temperature -40 °C copper
conductors
Photos
Martin Pekuri
30
Special precautions for single core cables Some other installation examples of single core
for a.c. wiring cables (phases 1, 2 and 3)
Whenever possible, a.c. wiring should be carried out with
multicore cables. When it is necessary to use single core cables, Four cables per phase
they should either be unarmoured or armoured with
a non-magnetic material. 1 3 3 1 or 1 2 3 3 2 1
When several multi or single core cables are connected 2 2 2 2 3 2 1 1 2 3
in parallel per phase, they should be of the same type 3 1 1 3
and equal length.
All cables pertaining to the same phase should be alternated Six cables per phase
with those of the other phases to avoid unequal division
of the current. In the case of two cables per phase, 1 3 3 1 1 3
for example, the correct dispositions to conform with
IEC 60092-352 (phases 1, 2 and 3) are: 2 2 2 2 2 2
3 1 1 3 3 1
or
1 2 3 3 2 1 or 1 2 3 1 2 3 3 2 1 1 2 3
3 2 1 3 2 1 1 2 3 3 2 1
Photos
Martin Pekuri
31
Current Rating Marine Cables
Cores 1 2 3 4 5 7 12 19 27 37 Correction 1,10 1,05 1,00 0,94 0,88 0,82 0,74 0,67 0,58
factor
Reduc- 1,00 0,85 0,70 0,70 0,58 0,52 0,44 0,37 0,33 0,30
tion
Short time duty and intermittent service load correction factors
(mm2) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (according to IEC 60092-352)
Photos
Martin Pekuri
32
32
Identification
Colours
5…37X White or black insulation with numbers 7…37G White or black insulation with numbers + last core green and yellow
1 1 2
2 3 4
N 2*N-1 2*N
kuvia!
33
Electrical Data Marine Cables
(W/km)
(n x mm2) (mm2) at +20 ˚C at +45 ˚C at +85 ˚C (mH/km)
34
34
Electrical Data
35