You are on page 1of 28

Product Overview

Combustion Technology

©DURAG GROUP

smart solutions for combustion and environment


DURAG combustion technology

(1)
Large-scale power plant

The DURAG GROUP’s products support all types


of industrial combustion processes throughout
the world. These include, for example, fossil fuel
power stations, plants in the chemical industry,
refineries, cement plants, waste incinerators,
steam generators, thermal power plants and gas
turbines.
We can also provide solutions for applications in
special environments, such as extreme climatic
zones or hazardous areas.

(2) (3)

Chemical process combustion Gas turbines

(4) (5) (6)


Waste gas heat treatment Rotary kiln Refinery

2
Flame sensor
Monitoring Flame monitor
Compact flame monitor

Industrial combustion
Igniting Controlling

Ignition transformer Burner control


Igniters Display module
Ignition lances
©DURAG GROUP

Flame monitoring Ionisation detection Ultra-violet detectors (UV) detect


the flame radiation below 400 nm. Ultra-violet
The monitoring of the flame is a safety engi- Flame monitors with ionisation detectors use the detectors are well suited for monitoring gas
neering element for industrial combustion ionising property of flames. They are used pri- flames but can also be used for oil flames.
technology – fuel may only enter the combus- marily on smaller gas burners and pilot burners. Products with the codes UL, US, UH, UA, and UAF
tion chamber if safe combustion is guaranteed. use these detectors.
Therefore high demands are made on the avail- Detection of the optical signal
ability and safety of the equipment used. For Detectors for visible radiation (VIS)
intermittent operation it is sufficient when the Large burners are monitored solely by optical are suitable for the monitoring of oil and coal
flame monitoring hardware performs a self test flame monitors. Depending on the fuel and flames between 400 and 800 nm. However,
during the startup procedure. Continuous opera- combustion technology of the process optical product guidelines in some countries stipulate
tion requires a permanent verification of error sensors with different spectral sensitivities or that gas flames must not be monitored in this
free operation, hence it is the more stringent combinations of them are used: spectral range. Products with the codes IS, ISE,
requirement. and ISO use these detectors.
The monitoring can be performed by the com- Infra-red detectors (IR) react to radiation
bination of a flame sensor (also flame scanner) having a wavelength of 800 nm or higher. It is
with a control unit. Where the flame sensor only the flickering of the flame which is analysed.
transforms characteristic properties of the flame Constant radiation sources, such as the glowing
into an electrical signal and the control unit of the furnace walls, are not detected as a flame.
provides the flame signal and ensures error free
operation. Alternatively these two parts are com- Flames radiating in the UV range, but whose UV
bined in one compact flame monitor. component is absorbed by dust, steam or other
Besides the proper selection of the flame moni- substances, can often also be monitored using
tor also its correct placement and alignment are infra-red detectors. Products with the codes IG,
important prerequisites for the successful moni- IGA, and ISF use these detectors.
toring of the flame. The presence of a flame must
be correctly detected independently of the con-
struction of the furnace or its operational mode.

3
AAL 75

Flame monitor
Particularly cost-effective, fail-safe
flame monitors for monitoring gas
and oil burners as well as combined
gas/ oil burners

AAL 75 D-LE 55 ULD-CG

©DURAG GROUP

Features Functional description Accessories

●● Monitoring of gas and oil burners of any load The flame monitor comprises of a control unit ●● Cable for connecting the ionisation elec-
●● Suitable for intermittent operation and and flame sensor. trode to the ionisation flame monitor
­continuous operation (only AAL 75 POD) ●● Optical flame sensors generate a signal from (kleZ912F0)
●● Simple installation on TS 35 DIN-rail the UV range of the flame radiation ●● Ball valve for closing the sighting tube
●● Flame sensors with an ionisation electrode (D-ZS 133 III)
Applications process a current flowing through the flame ●● Swivel mount for alignment of the flame
sensor to the flame to be monitored
●● Chemical industry Models (D-ZS 033 III)
●● Refineries ●● Test light source for AAL75/ D-LE 55 ULD-CG
●● Cement plants ●● AAL 75 for functional test of the flame monitor,
●● Waste incinerators Ionisation flame monitor for intermittent battery operated (D-ZS 091)
●● Steam generators or continuous operation, also suitable for ●● Thermal isolator with electrical insulation
●● Heating plants single electrode operation in conjunction for D-LE 55 ULD-CG flame sensor
with DURAG ignition transformers, model (D-ZS 117 III)
Certifications D-HG 55
●● AAL 75
●● DVGW as UV flame monitor in combination with
●● FM Class 7610 D-LE 55 ULD-CG for the optical monitoring
●● EAC of gas flames in intermittent mode

Flame sensor

Ionisation electrode

AAL 75

©DURAG GROUP

Flame monitor (control unit) Flame sensor


Type AAL 75 Spectral D-LE 55 UD-CG:
sensitivity 190 – 270 nm
Operational mode Intermittent operation
Electrical connection 115/ 230 VAC, 50/ 60 Hz
Perm. ambient -20 °C bis +60 °C Perm. ambient -20 °C to +60 °C
temperature temperature
FFDT (safety time) 1s Mounting G 1“ or G ½“
Display LED Protection IP65
Protection IP20 Dimensions Ø 27 mm, length 116 mm
Flame relay 2 relay outputs: 250 VAC/ 315 Weight 0.45 kg
mA and 250 VAC/ 2 A
Installation TS 35 DIN-rail
Dimensions 68x104x119 mm (WxHxD)
Weight 0.55 kg

4
D-LX 100

Compact flame
monitor
Self-monitoring and fail-safe
­compact flame monitor for
monitoring gas, oil and coal flames
with integrated UV, VIS or IR flame
sensor, primarily in single burner
view applications D-LX 100

©DURAG GROUP

Features Functional description Accessories

●● Suitable for intermittent operation as well The D-LX 100 flame monitor analyses flame ra- ●● Digital display for optimal adjustment of the
as continuous operation diation using the integrated flame sensor signal. flame sensors by measuring the pulse rate
●● Compact design, flame sensor and control The flame intensity is present as a current at one and its extreme values (D-ZS 087 - 20)
unit in one enclosure, takes up no space in output 0/4 ... 20mA for further analysis. ●● Optical adjustment aid for the alignment of
control cabinet the swivel mount on the sighting tube
●● LED display for settings and operational Design (D-ZS 118)
­status ●● UV-C test light source 230 V/ 50 Hz
●● ATEX approved (D-LX 100.../94Ex for zone 1 ●● Integrated compact device (D-ZS 077-10)
and D-LX 100.../97Ex for zone 2) ●● UV-A, UV-B and IR test light source
230 V/ 50 Hz (D-ZS 093)
Applications ●● Swivel mount for alignment of flame moni-
tor to the flame to be monitored
●● Power stations ●● Thermal isolator with electrical insulation
●● Chemical industry ●● Ball valve for closing sighting tube
●● Refineries ●● Terminal box for connecting the flame
●● Cement plants monitor (D-ZS 140/ 141)
●● Waste incinerators ●● Power supply unit to supply two D-LX 100
D-LX 100.../94Ex
●● Steam generators D-LX 100.../95Ex (D-NG 24/05)
●● Heating plants

Certifications ©DURAG GROUP

●● SIL3 Digital display


●● DVGW D-ZS 087-20 (optional)
●● UL 372
●● FM Class 7610
●● AGA: AS 4625
●● EAC
●● ATEX

Thermal isolator Ball valve


Flame monitor Purge air with electrical D-ZS 133 I
D-LX 100 flange insulation (optional) Swivel mount
D-ZS 117 I D-ZS-033 I
(optional) (optional)

©DURAG GROUP

Operational mode Intermittent operation, continuous Flame intensity 0/4 ... 20mA
operation, 72-hour operation
without permanent supervision
Safety Self-monitoring and fail-safe Perm. ambient -20 °C to +60 °C
temperature
Electrical 24 VDC, 5 W, PELV Dimensions 90x92 mm, length approx.
connection Weight 350 mm/ approx. 1.8 kg
Protection class IP67 Sighting tube G 1¼“
connection
Flame relay 1x NO contact, 230 VAC/ 2 A Purge air G ½“
connection
Status relay 1x NO contact, 230 VAC/ 2 A D-LX 100.../9xEx
FFDT (safety time) 1, 3, 5 s /94Ex II 2G Ex de IIC T5/T6
/95Ex Class l, Div. 1, Group B, C & D
Spectral ranges UV, VIS, IR /96Ex Class l, Div. 2, Group A, B, C & D
Viewing angle 6° /97Ex II 3G Ex nAnC IIC T6
Number of ranges 1 Protection class IP65
Switching 0 ... 9 /94Ex, /95Ex
threshold Dimensions Ø 130 mm, length 313 mm
Weight approx. 4.3 kg
Display LED display Sighting tube G1“ (/94Ex, /95Ex)
connection G 1¼“ (/96Ex, /97Ex)

5
D-LX 200 D-LX 200 Ex

Compact flame
monitor
Self-monitoring and fail-safe com-
pact flame monitor for monitoring
gas, oil, and coal flames with inte-
grated UV or IR flame sensor

D-LX 200.../87Ex D-LX 200 ©DURAG GROUP

Features Functional description Accessories

●● Wide sensitivity range The D-LX 200 compact flame monitor analyses ●● Optical adjustment aid for the swivel
●● For ambient temperatures from -40 °C up to flame radiation using the integrated flame sen- mount on the sighting tube (D-ZS 118)
+85 °C sor signal. Current output 0/4 ... 20 mA available ●● LED bar graph display for the flame
●● Dual channel design throughout for further analysis. Flame properties and para- intensity (D-ZS 129)
●● Measurement of flame flicker frequency meters of the flame monitor can be transmitted ●● D-LX 200 Test Kit for performing software
●● Selective to individual burners and fuels to a PC via a RS485 and an IrDA interface. supported tests
●● Swivel mount for aligning the flame monitor
Applications ©DURAG GROUP ●● Thermal isolator with electrical insulation
●● Ball valve for closing the sighting tube
●● Power stations ●● Terminal box for connecting the flame
●● Chemical industry monitor (D-ZS 140-12)
●● Refineries ●● Power supply unit for supply of up to two
●● Cement plants D‑LX 200 (D-NG 24/05)
●● Waste incinerators
●● Steam generators
●● Heating plants

Certifications User interface of the flame monitor software


©DURAG GROUP

●● DVGW
●● FM Class 7610
●● CSA
●● SIL3
Thermal isolator
●● EAC with electrical
Ball valve
Flame monitor Purge air D-ZS 133 I
●● AGA: AS 4625 D-LX 200 flange insulation (optional) Swivel mount
D-ZS 117 I D-ZS-033 I
●● ATEX , IECEx (optional) (optional)
●● Marine Certifications

Thermal isolator Ball valve


Purge air with electrical D-ZS 133 I
flange insulation (optional) Swivel mount
Flame monitor D-ZS 117 I
D-LX 200.../8xEx D-ZS-033 I
(optional) (optional)

Operational mode Intermittent operation and Purge air G ½“ or ½” NPT(F)


continuous operation connection
Safety Self-monitoring and fail-safe Spectral ranges UV, IR
Electrical 24 VDC, 5 W, PELV Threshold switches Flame intensity and flicker
connection frequency
Protection class IP66/ 68, IP65 (/MP) D-LX 200 /8xEx
Flame relay 1x NO contact, 24 VDC, 0.5 A /84Ex II 2G Ex d IIC T6 or T5 Gb
II 2D Ex tb IIIC T85 °C or T100 °C Db
Status relay 1x NO contact, 24 VDC, 0.5 A /85Ex Cl. I, Div. 1, Gr. A, B, C, D T6/T5
FFDT (safety time) 1, 2, 3, 5 s Cl. II, Div. 1, Gr. E, F, G T6/T5; Cl. III
Type 4
Viewing angle 6° Hazardous locations: indoor/outdoor
Ranges 2 /86Ex Cl. I, Div. 2, Gr. A, B, C, D T6/T4
Cl. II, Div. 2, Gr. E, F, G T6/T4; Cl. III
Type 4
Hazardous locations: indoor/outdoor
Communication LED, Modbus RTU, IrDA /87Ex II 3G Ex nAnC IIC T6 or T4 Gc
II 3D Ex tc IIIC T85 °C or T135 °C Dc
Analogue output 0/4 ... 20 mA Protection class IP66
Ambient -40 °C to +85 °C Dimensions Ø 120 mm, length 307 mm
temperature range
SIL3 Dimensions
Weight
85x85 mm, length approx. 250 mm Weight
approx. 1.25 kg
ca. 3.2 kg

Sighting tube G 1¼“ or 1¼” NPT(F) Tmax (/86Ex, /87Ex) +65 °C


connection

6
D-LE 103

Flame sensor
Flame sensor for monitoring gas,
oil and coal flames, primarily in
single burner view applications

D-LE 103

©DURAG GROUP

Features Functional description Accessories

●● Self-monitoring and fail-safe in conjunction The photo element in the flame sensor gener- ●● Optical adjustment aid for alignment of the
with a control unit/ burner control ates a signal which is proportional to the flame swivel mount on the sighting tube
●● Flame sensors for every spectral range of radiation intensity. The output signal of the (D-ZS 118)
flame monitoring from UV to IR flame sensor is used as an input signal to a con- ●● UV-C test light source 230 V/ 50 Hz
●● Connection to D-UG 120 and D-UG 660 trol unit or a burner control. (D-ZS 077-10)
contol unit as well as D-GF 150 (-MB) burner The D-LE 103 flame sensor is available with dif- ●● UV-A, UV-B und IR test light source
control ferent photo elements for optimal selectivity 230 V/ 50 Hz (D-ZS 093)
●● Uniform output signal thus mutually inter- when using different fuels. ●● Swivel Mount for alignment of flame sensor
changeable to the flame to be monitored
●● Compliant to general safety regulations Models ●● Thermal isolator with electrical insulation
●● Ball valve for closing sighting tube
Applications ●● Cable gland (-CG) ●● Terminal box for connecting flame sensor
●● Axial plug (-P) (D-ZS 140)
●● Power stations
●● Chemical industry
●● Refineries Flame sensor selection
●● Cement plants
Flame sensor Suitability for fuels
●● Waste incinerators
●● Steam generators Gas Oil Coal Wood
●● Heating plants D-LE 103 UL ++ +
D-LE 103 UAF o ++
Certifications D-LE 103 UA + ++ o +
D-LE 103 IS ! ++ ++ +
●● DVGW D-LE 103 IG o ++ ++ ++
●● UL 372 ++ ideally suited + well suited o conditionally suited ! not permitted (from experience)
●● FM Class 7610
●● AGA: AS 4625
●● EAC
●● SIL3 ©DURAG GROUP

Control unit/
Burner control

D-UG 120
D-UG 660
D-GF 150
Flame sensor Purge air Thermal Ball valve
D-LE 103 flange isolator with D-ZS 133 I
electrical (optional) Swivel
insulation mount
D-ZS 117 I D-ZS-033 I
(optional) (optional)

Operational Intermittent operation, continuous Viewing angle 6°


mode operation and 72-hour operation
without permanent supervision
Safety self-monitoring and fail-safe in Perm. ambient -20 °C to +60 °C
conjunction with a control unit/ temperature
burner control
Protection with cable gland Dimensions Ø 80 mm,
(D-LE 103 ... -CG) IP65 length approx. 350 mm
with axial plug Weight approx. 1 kg
(D-LE 103 ... -P) IP67
Gain pre-set Sighting tube G 1¼“
connection
High-pass filter pre-set Purge air G ½“
connection
Spectral ranges UV, VIS, IR

7
D-LE 603 D-LE 603 Ex

Flame sensor ©DURAG GROUP

Flame sensor for monitoring gas,


oil and coal flames, primarily in
multi-burner view applications

D-LE 603

D-LE 603.../94Ex
D-LE 603.../95Ex

Features Functional description ●● Optical adjustment aid for alignment of the


swivel mount on the sighting tube (D-ZS 118)
●● Self-monitoring and fail-safe in conjunction The photo element in the flame sensor gener- ●● UV-C test light source 230 V/ 50 Hz
with a control unit/ burner control ates a signal which is proportional to the flame (D-ZS 077-10)
●● Flame sensors for every spectral range from radiation intensity. The output signal of the ●● UV-A, UV-B and IR test light source
UV to IR flame sensor is used as an input signal to a con- 230 V/ 50 Hz
●● Connection to the D-UG 120 control unit, trol unit or a burner control. ●● Swivel mount for the alignment of the flame
D-UG 660 control unit as well as to the The D-LE 603 flame sensor is available with dif- sensor
D-GF 150 (-MB) burner control ferent photo elements for maximum selectivity ●● Thermal isolator with electrical insulation
●● Uniform output signal thus mutually inter- when using various fuels. ●● Ball valve for closing the sighting tube
changeable ●● Terminal box for connecting flame sensor
●● Adjustable to different combustion technolo- Accessories (D-ZS 140/ 141).
gies such as exhaust gas recirculation
●● Compliance to general safety regulations ●● Digital display for optimal alignment of
●● ATEX approved (D-LE 603 .../94 Ex for zone 1 flame sensors (D-ZS 087 - 20)
and D-LE 603 .../97Ex for zone 2) Flame sensor selection
Flame sensor Suitability for fuels Features
Applications Gas Oil Coal Wood
D-LE 603 UH ++ o selective single burner monitoring in multiple-burner plants
●● Power stations
D-LE 603 US ++ + at low UV radiation
●● Chemical industry
D-LE 603 UAF o ++ with intensive ambient light (neighbouring burners), gain switchover
●● Refineries
D-LE 603 UA + ++ + o at low NOx component, gain switch-over
●● Cement plants
●● Waste incinerators D-LE 603 UI ++ ++ + + remote changeover of spectral sensitivity
●● Steam generators D-LE 603 IS ! + ++ + selective single burner monitoring (coal, oil)
●● Heating plants D-LE 603 IG o + ++ ++ selective single burner monitoring (coal, oil, wood)
D-LE 603 ISE ! ++ dual-channel flame sensor (LOG/LOG)
Certifications D-LE 603 ISO ! ++ dual-channel flame sensor (LIN/LOG)
++ ideally suited + well suited o conditionally suited ! not permitted (from experience)
●● DVGW ©DURAG GROUP
●● UL 372 Digital display
●● FM Class 7610 D-ZS 087-20 (optional)

●● AGA: AS 4625
●● EAC
Control unit/
●● ATEX Burner control
●● SIL3 D-UG 120
D-UG 660
D-GF 150
Thermal isolator Ball valve
Flame sensor Purge air with electrical D-ZS 133 I
D-LE 603 flange insulation (optional) Swivel
D-ZS 117 I mount
(optional) D-ZS-033 I
(optional)
Operational mode Intermittent operation, continuous Dimensions 90x92 mm, length approx. 350 mm
operation and 72-hour operation
without permanent supervision Weight approx 1.8 kg

Safety Self-monitoring and fail-safe in Sighting tube G 1¼“


conjunction with a control unit/ connection
burner control
Purge air G ½“
connection
Protection class with cable gland D-LE 603 .../9xEx
(D-LE 603 ... -CG) IP65
with axial plug Protection class IP65
(D-LE 603 ... -P) IP67 /94Ex II 2G Ex de IIC T5/T6
/95Ex Class l, Div. 1, Group B, C & D
Gain four settings /96Ex Class l, Div. 2, Group A, B, C & D
High-pass filter three settings /97Ex II 3G Ex nAnC IIC T6
Spectral ranges UV, VIS, IR /94Ex, /95Ex
Dimensions Ø 130 mm, length 313 mm
Viewing angle 6° Weight approx. 4.3 kg
Perm. ambient -20 °C to +60 °C Sighting tube G1“ (/94Ex, /95Ex)
temperature connection G 1¼“ (/96Ex, /97Ex)

8
D-LE 701 D-LE 703

Flame sensor with


fibre optic system
Systems for flame monitoring:

D-LE 701 flame sensor with


– flexible fibre optic system D-LL 701
– rigid ­fibre optic system D-LL 702
D-LE 703 flame sensor with D-LE 701 D-LE 703
– flexible fibre optic system D-LL 703 ©DURAG GROUP
– rigid fibre optic system D-LL 704
Features Functional description Accessories

●● Self-monitoring and fail-safe flame sensor The fibre optic system may be integrated directly ●● Digital display for measuring the pulse rate
with a fibre-optic connection in conjunction into the hot area of the burner. It transfers the ra- and its extreme values
with a control unit/ burner control diation from the flame over a fibre optic bundle (D-ZS 087-20)
●● Monitoring of gas, oil and coal flames to the flame sensor installed outside the burner. ●● UV-A, UV-B and IR test light source
●● Connection to the D-UG 120, D-UG 660 It is available in different lengths. 230 V/ 50 Hz (D-ZS 093)
control unit and the D-GF 150 (-MB) burner The photo element in the flame sensor gener- ●● Terminal box for connecting flame sensor
control ates a signal which is proportional to the flame (D-ZS 140)
●● Spectral range from UV to IR radiation intensity. The output signal of the ●● Installation flange for D-LL 702 for fibre
●● Uniform output signal thus mutually inter- flame sensor is used as an input signal to a con- ­optic system (D-ZS 702)
changeable trol unit or a burner control. ●● Welding flange for D-LL 702 for fibre optic
●● Adjustable to different combustion technolo- system (D-ZS 704)
gies such as exhaust gas recirculation

Applications Flame sensor selection


Flame sensor Suitability for fuels Features
●● Burners with difficult installation conditions Gas Oil Coal Wood
for conventional flame sensors or on those
D-LE 701 / 703 UAF o ++ with intensive ambient light (neighbouring burners), gain
where ambient temperature near the sight- switchover
ing tube is very high D-LE 701 / 703 UA + ++ + with low NOx component, gain switchover
●● Power stations D-LE 701 / 703 IS ! + ++ + selective single burner monitoring (coal, oil)
●● Chemical industry
D-LE 701 IGA / 703 IG o + ++ ++ selective single burner monitoring (coal, oil, wood)
●● Refineries
++ ideally suited + well suited o conditionally suited ! not permitted (from experience)
●● Cement plants
●● Waste incinerators
●● Steam generators
●● Heating plants

Certifications

●● DVGW
●● EAC
●● SIL3 Flame sensor
D-LE 703

Flame sensor
D-LE 701 ©DURAG GROUP

D-LE 701 flame sensor D-LE 703 flame sensor


Operation mode Intermittent operation, continuous Operation mode Intermittent operation, continuous
operation and 72-hour operation operation and 72-hour operation
without permanent supervision without permanent supervision
Safety Self-monitoring and fail-safe in Safety Self-monitoring and fail-safe
conjunction with a control unit/
burner control
Protection with cable gland Protection with cable gland
(D-LE 701 ... -CG) IP65 (D-LE 703 ... -CG) IP65
with axial plug with axial plug
(D-LE 701 ... -P) IP67 (D-LE 703 ... -P) IP67
Gain four settings Gain four settings
High-pass filter three settings High-pass filter three settings
Spectral ranges UV, VIS, IR Spectral ranges UV, VIS, IR
Perm. ambient -20 °C to +60 °C Perm. ambient -20 °C to +60 °C
temperature temperature
Dimensions 160x185x100 mm (WxHxD) Dimensions 90x92 mm, length approx. 270 mm
Weight approx. 1.2 kg Weight approx 1.2 kg

9
D-LX 720

Compact flame
monitor with fibre
optic system
Application with
- flexible fibre optic system
D-LL 703
- or rigid fibre optic system D-LX 720
D-LL 704
©DURAG GROUP

Features Functional description Accessories

●● Wide sensitivity range The D-LX 720 compact flame monitor is elec- ●● LED bar graph display for the flame intensi-
●● For ambient temperatures from -40 °C up to tronically identical to the D-LX 200. It analyses ty (D-ZS 129)
+85 °C flame radiation using the integrated flame sen- ●● D-LX 200 Test Kit for performing software
●● Dual channel design throughout sor signal. supported tests
●● Measurement of flame flicker frequency Current output 0/4 ... 20 mA available for further ●● Terminal box for connecting the flame
●● Selective to individual burners and fuels analysis. monitor (D-ZS 140-12)
Flame properties and parameters of the flame ●● Installation flange for D-LL 703 fibre optic
Applications monitor can be transmitted to a PC via a RS485 system (D-ZS 703)
and an IrDA interface. ●● Welding flange for D-LL 704 fibre optic
●● Burners with difficult installation conditions ­system (D-ZS 704)
for conventional flame sensors or on those ●● Power supply unit for supply of up to two
where ambient temperature near the sight- D‑LX 720 (D-NG 24/05)
ing tube is too high
●● Power stations
©DURAG GROUP
●● Chemical industry
●● Refineries
●● Cement plants
●● Waste incinerators
●● Steam generators
●● Heating plants

Certifications

●● DVGW
D-LX 720.../87Ex
●● FM Class 7610
User interface of the flame monitor software ©DURAG GROUP
●● CSA
●● SIL3
●● EAC
●● AGA: AS 4625
●● ATEX , IECEx
●● Marine Certifications

Operational mode Intermittent operation and Threshold switches Flame intensity and flicker
continuous operation frequency
Safety Self-monitoring and fail-safe D-LX 720 .../8xEx
Electrical 24 VDC, 5 W, PELV /84Ex II 2G Ex d IIC T6 or T5 Gb
connection II 2D Ex tb IIIC T85 °C or T100 °C Db
/85Ex Cl. I, Div. 1, Gr. A, B, C, D T6/ T5
Protection class IP66/ 68, IP65 (/MP) Cl. II, Div. 1, Gr. E, F, G T6/ T5; Cl. III
Flame relay 1x NO contact, 24 VDC, 0.5 A Type 4
Hazardous locations: indoor/outdoor
Status relay 1x NO contact, 24 VDC, 0.5 A /86Ex Cl. I, Div. 2, Gr. A, B, C, D T6/ T4
FFDT (safety time) 1, 2, 3, 5 s Cl. II, Div. 2, Gr. E, F, G T6/T4; Cl. III
Type 4
Hazardous locations: indoor/outdoor
Ranges 2 /87Ex II 3G Ex nAnC IIC T6 or T4 Gc
II 3D Ex tc IIIC T85 °C or T135 °C Dc
Communication LED, Modbus RTU, IrDA
Analogue output 0/4 ... 20 mA Protection class IP66
Ambient -40 °C to +85 °C Dimensions Ø120 mm, length 229 mm
SIL3 temperature range
Dimensions 85x85 mm, length approx. 175 mm Weight ca. 3.2 kg
Weight approx. 1.25 kg
Spectral ranges UV, IR Tmax /86Ex, /87Ex +65 °C

10
D-LL 701 D-LL 702 D-LL 703 D-LL 704

Fibre optic systems


­ he flexible and rigid fibre optic
T
systems may be integrated ­directly
into the hot area of the burner. It
transfers the radiation from the
flame over a fibre optic ­bundle to ©DURAG GROUP
the flame sensor installed outside
the burner Protection hose
min 0.5 m
Length of rigid intermediate pipe
min 0.2 m
Length of flexible
intermediate pipe, min 0.5 m

D-LL 701 fibre optic system


Ø 40 mm
●● Flexible fibre optic system
D-LL 701: flexible fibre optic system for D-LE 701
●● Flame sensor and optics of the fibre optic
system are connected by a glass fibre Spectral ranges UV, IR Purge air G ½“
connection
bundle which is surrounded by a flexible
Viewing angle 6° Intermediate pipe 1.4301
protection hose material
●● Suitable for temperatures up to 350 °C Perm. ambient -40 °C to +350 °C (optical system) Weight approx. 1.6 kg + 1 kg/m
temperature

©DURAG GROUP
Protection hose Rigid guiding tubing
min 0.5 m min 0.2 m, max 15 m

D-LL 702 fibre optic system


Ø 22 mm
●● Rigid fibre optic system D-LL 702: rigid fibre optic system for D-LE 701
●● Flame sensor and optics of the fibre optic Spectral ranges UV, IR Purge air G ½“
system are connected by a glass fibre connection
bundle which is surrounded by a flexible Viewing angle 6° Guiding tube 1.4301
protection hose material
●● Suitable for temperatures up to 350 °C Perm. ambient -40 °C to +350 °C (optical system) Weight approx. 1.6 kg + 1 kg/m
temperature

©DURAG GROUP
Length of rigid intermediate Length of flexible intermediate
pipe, min 0.2 m pipe, min 0.5 m

D-LL 703 fibre optic system Ø 40 mm

●● Flexible fibre optic system D-LL 703: flexible fibre optic system for D-LE 703 and D-LX 720
●● For combination with flame sensor or Spectral ranges UV, IR Cooling air G ½“
connection
compact flame monitor
●● The optics of the fibre optic system are Viewing angle 6° Intermediate pipe 1.4301
material
connected to the sensor by a multiple
Perm. ambient -40 °C to +350 °C (optical system) Weight approx. 3 kg + 1 kg/m
protected glass fibre bundle temperature
●● Suitable for temperatures up to 350 °C Purge air G ½“
connection
©DURAG GROUP
Rigid guiding tubing
pipe, min 0.5 m, max 20 m

D-LL 704 fibre optic system Ø 22 mm

●● Rigid fibre optic system D-LL 704: rigid fibre optic system for D-LE 703 and D-LX 720
●● For combination with flame sensor or Spectral ranges UV, IR Cooling air G ½“
compact flame monitor connection
●● The optics of the fibre optic system are Viewing angle 6° Guiding tube 1.4301
material
connected to the sensor by a multiple
Perm. ambient -40 °C to +350 °C (optical system) Weight approx. 2 kg + 1 kg/m
protected glass fibre bundle temperature
●● Suitable for temperatures up to 350 °C Purge air G ½“
connection

Applications

●● Tilting burner (flexible system) ●● Chemical industry


●● Burners with difficult installation conditions ●● Refineries
for conventional flame sensors or on those ●● Cement plants
whose ambient temperature near the ●● Waste incinerators
sighting tube is too high ●● Steam generators, heating plants
●● Power stations

11
D-GT 800

Flame sensor
Flame sensor for monitoring gas
and oil flames, primarily in gas
turbines or in particularly harsh
­environments

D-GT 800-P

©DURAG GROUP

Features Functional description Models

●● Self-monitoring and fail-safe in conjunction With its combination of a highly sensitive photo ●● Cable gland connection (-Ex)
with a control unit/ burner control element and sturdy design, the D-GT 800/801 ●● Axial plug (-P)
●● Deployable with high combustion chamber flame sensors are ideal for use in harsh environ- ●● Available with air or water cooling for very
overpressure and with strong vibrations ments such as in gas turbines. The photodiode high temperatures (D-GT 800)
●● Connection to the D-UG 120, D-UG 660 used can detect almost all blue burning flames,
control units and the D-GF 150 (-MB) burner such as gas flames having only a low radiation Accessories
control component in the visible range.
●● Optionally available with air/water cooling The D-GT 800/801 is available with different ●● UV-A, UV-B and IR test light source
●● Compliant to general safety regulations photo elements for optimal selectivity when us- 230 V/ 50 Hz (D-ZS 093)
●● Flame monitoring in the UV-range from 190 ing different fuels. ●● Terminal box for connecting the flame
to 570 nm ­sensor (D-ZS 140, D-ZS 141)
●● ATEX-approved (D-GT 800/801../Ex) Flame sensor selection
Flame sensor Suitability for Features
Applications Gas Oil
D-GT 800/801 UAF o ++ with intensive ambient light (neighbouring burners)
●● Burners with difficult installation conditions
D-GT 800/801 UA + ++ at low NOx component
for conventional flame sensors or on those
++ ideally suited + well suited o conditional suited ! not permitted (from experience)
where ambient temperature near the
sighting tube is very high
●● Power stations
●● Chemical industry
●● Refineries ©DURAG GROUP
●● Cement plants
●● Waste incinerators Control unit/
Burner control
●● Steam generators
●● Heating plants D-UG 120
D-UG 660
●● Gas turbines D-GF 150

Certifications (only D-GT 800/801)


D-GT 800/ Ex
●● DVGW
●● EAC Control unit/
Burner control
●● ATEX
D-UG 120
D-UG 660
D-GF 150

D-GT 801/ Ex (without cooling jacket)

Operational mode Intermittent operation, continuous Perm. ambient Without cooling: -20 °C to +120 °C
D-GT 800/801 operation and 72-hour operation temperature Air cooling: -20 °C to +200 °C
without permanent supervision Water cooling: -20 °C to +300 °C
Safety Self-monitoring and fail-safe in Vibration 10 g
conjunction with a control unit/
burner control Dimensions Ø 100 mm; length approx. 190 mm

Protection With cable gland Weight Without cooling: approx. 1.5 kg


(D-GT 800/801 -P) IP67 with cooling: approx. 2.0 kg
Ex-Version
(D-GT 800/801 .../Ex) IP66
Ex-Protection II 2G Ex d T4/T5/T6 Max combustion 30 bar
(D-GT 800/801../ chamber
Ex) overpressure
Spectral range UV Sighting tube ¾“ NPT (F)
connection
Viewing angle 6° Cooling ½“ NPT (F)
connection

12
D-UG 120

Control unit ©DURAG GROUP

Self-monitoring and fail-safe con-


trol unit for monitoring gas, oil and
coal flames with DURAG UV, UV+IR
or IR flame sensors, primarily in sin-
gle burner view applications

D-UG 120

Features Functional description Accessories

●● Suitable for intermittent operation as well The D-UG 120 control unit analyses the flame ●● Power supply unit for connecting the
as continuous operation ­radiation via the signal of the flame sensor con- D-UG 120 to 230VAC (D-NG 24/05)
●● LED display nected. ●● Digital display for optimal adjustment of the
●● Installation on DIN-rail The easy-to-read LED display shows the opera- flame sensors by measuring the pulse rate
tional status of the flame monitor. and its extreme values (D-ZS 087 - 20)
Applications The flame intensity is present as a current at an ●● Optical adjustment aid for the alignment of
output 0/4 ... 20 mA for further analysis. the swivel mount on the sighting tube
●● Power stations (D-ZS 118)
●● Chemical industry Flame sensors ●● UV-C test light source
●● Refineries 230 V/ 50 Hz (D-ZS 077-10)
●● Cement plants ●● D-LE 103 for standard applications ●● UV-A, UV-B and IR test light source
●● Waste incinerators ●● D-LE 603 for selective flame monitoring 230 V/ 50 Hz (D-ZS 093)
●● Steam generators ●● D-LE 701/703 for special applications (fibre ●● Swivel mount for alignment of flame moni-
●● Heating plants optics) tor to the flame to be monitored
●● D-GT 800 for particularly harsh environments ●● Thermal isolator with electrical insulation
Certifications ●● Sensors for Ex-applications are also available ●● Ball valve for closing sighting tube
●● Terminal box for connecting flame monitor
●● DVGW Design (D-ZS 140/ 141)
●● UL 372
●● FM Class 7610 ●● Enclosure for DIN-rail mounting
●● EAC
●● SIL3

©DURAG GROUP

Flame sensor Purge air Thermal Ball valve


e.g. D-LE 103 flange isolator D-ZS 133 I Swivel
Mains adapter Control unit with (optional)
D-NG 24/05 D-UG 120 mount
electrical D-ZS-033 I
(optional) insulation (optional)
D-ZS 117 I
(optional)
Digital display
D-ZS 087-20
(optional)

Operation mode Intermittent operation, continuous Configurable 1


operation, 72-hour operation switching
without permanent supervision thresholds
Safety Self-monitoring and fail-safe Threshold setting 0 ... 9
Electrical 24 VDC, 5 W, PELV Flame sensor 1
connection
Protection IP20 Display LED
Flame relay 1x NO contact, 230 VAC, 2 A Flame intensity 0/4 ... 20 mA
Status relay 1x NO contact, 230 VAC, 2 A Perm. ambient -20 °C to +60 °C
temperature
Installation TS 35 DIN-rail Dimensions 100x75x118 mm (WxHxD)
FFDT (safety time) 1 s Weight approx. 0.45 kg

13
D-UG 660

Control unit
Self-monitoring and fail-safe con-
trol unit for monitoring gas, oil and
coal flames with DURAG UV, UV+IR
or IR-flame sensors, primarily in
multi-burner view applications

D-UG 660 ©DURAG GROUP

Features Functional description Accessories

●● Suitable for intermittent operation as well as The D-UG 660 control unit analyses the flame ●● Digital display for optimal adjustment of the
continuous operation radiation via the pulse signal of the flame sensor flame sensors by measuring the pulse rate
●● Optional parallel operation of two flame connected. and its extreme values (D-ZS 087 - 20)
sensors in any combination: UV/ UV, UV/IR The easy-to-read LCD display continually shows ●● Optical adjustment aid for the alignment of
or IR/ IR information on the defined setting and opera- the swivel mount on the sighting tube
●● Three different settings supported for vari- tional status. (D-ZS 118)
ous modes (e.g. dependent on fuel or com- The flame intensity and signal are present at two ●● UV-C test light source
bustion technology), automatic activation by current outputs 0/4 ... 20 mA for further analysis. 230 V/ 50 Hz (D-ZS 077-10)
burner management system ●● UV-A, UV-B and IR test light source
●● Plain text display Flame sensors 230 V/ 50 Hz (D-ZS 093)
●● Swivel mount for alignment of flame moni-
Applications ●● D-LE 103 for standard applications tor to the flame to be monitored
●● D-LE 603 for selective flame monitoring ●● Thermal isolator with electrical isolation
●● Power stations ●● D-LE 701/ 703 for special applications (fibre ●● Ball valve for closing sighting tube
●● Chemical industry optics) ●● Terminal box for connecting flame monitor
●● Refineries ●● D-GT 800 for particularly harsh environments (D-ZS 140/ 141)
●● Cement plants ●● Sensors for Ex-applications are also available ●● Various enclosures and racks for 1 to 4
●● Waste incinerators devices
●● Steam generators Design
●● Heating plants
●● Plug-in module (21HP and 3RU) for 19“ racks
Certifications (IP00)
©DURAG GROUP

●● DVGW Digital display


●● UL 372 D-ZS 087-20 (optional)
●● FM Class 7610
●● AGA: AS 4625
●● EAC
●● SIL3

Flame sensor Purge air Thermal Ball valve


e.g. D-LE 103 flange isolator with D-ZS 133 I Swivel
electrical (optional) mount
Second flame insulation D-ZS-033 I
sensor D-ZS 117 I (optional)
Control unit (optional)
D-UG 660 (optional)

Operation mode Intermittent operation, continuous Pre-configurable 3


operation, 72-hour operation combinations
without continual supervision of switching
threshold and
safety time
Safety Self-monitoring and fail-safe Flame sensor 1 or 2 (parallel)
connection
Electrical 24/ 48 VDC, Display alpha-numeric LCD display
connection 115/ 230 VAC
Protection IP00 Flame intensity 0/4 ... 20 mA
Flame relay 1x switch-over contact, Flame signal 0/4 ... 20 mA
230 VAC, 2 A
Status relay 1x switch-over contact, Perm. ambient -20 °C to +60 °C
230 VAC, 2 A temperature
Threshold setting 00 ... 99 Dimensions 19” plug-in module, 3 RU, 21 HP
FFDT (safety time) 1 ... 5.5 s Weight approx. 1 kg
14

14
D-GF 150 D-GF 150-MB

Burner control ©DURAG GROUP

Self-monitoring and fail-safe burner


control for the control of gas and oil
burners as well as combined gas/ oil
burners of any capacity

D-GF 150-MB

Features Functional description Flame sensors

●● Controlling and monitoring of gas and oil Generally used fuel types and burners require ●● D-LE 103 for standard applications
burners of any capacity certain synchronised program cycles and safety ●● D-LE 603 for selective flame monitoring
●● Suitable for intermittent operation as well as times for burner start-up which are controlled ●● D-LE 701/ 703 for special applications with
continuous operation and monitored electronically with the burner fibre-optic systems
●● Integrated gas valve monitoring system control. ●● D-GT 800 for particularly harsh environments
●● Separate outputs for control of gas and oil The following program cycles may be selected ●● Flame sensor for use in potentially explosive
fuel valves on the D-GF 150 automatic firing device: atmospheres are also available
●● Quick fuel change “on the fly” without burner ●● Gas fuel with boiler pre-purge
shut down ●● Gas fuel without boiler pre-purge Design
●● Adjustable pre-purge timer ●● Oil fuel with boiler pre-purge
●● Integrated flame monitor ●● Oil fuel without boiler pre-purge. ●● Device installed on the TS 35 DIN-rail.
●● Input for external flame monitor
●● Data interfaces D-GF 150-MB Additional equipment
●● Status displays (LED or text) ●● Integrated text display for messages of
status, program step and errors ●● First out annunciator, plain text display,
Applications ●● RS485 communication port for supply of fieldbus communication (D-AM 150)
parameters, settings and present status via ●● Digital display for optimal adjustment of the
●● Chemical industry Modbus protocol flame sensors by measuring the pulse rate
●● Refineries and its extreme values (D-ZS 087 - 20)
●● Cement plants
●● Waste incinerators
●● Steam generators
●● Heating plants
Digital display
Certifications D-ZS 087-20 (optional)

●● DVGW
●● UL 372
●● FM Class 7610
●● AGA: AS 4625
●● EAC Flame sensor Purge air Thermal/ Ball valve
e.g. D-LE 603 flange electrical D-ZS 133 I Swivel
isolator (optional) mount
D-ZS 117 I D-ZS-033 I
Second flame (optional)
sensor (optional)
Burner control (optional)
D-GF 150-MB

©DURAG GROUP

Operational mode Intermittent operation, continuous Flame sensor 1, 2 parallel or external flame
operation, 72-hour operation
without permanent supervision Display LED

Safety Self-monitoring and fail-safe Flame intensity 0/4 ... 20 mA


Electrical 115/ 230 VAC , 50/ 60 Hz Data output to D-AM 150/ D-ZS 087-20
connection
Protection IP20 Dimensions 170x130x114 mm (WxHxD)
Weight approx. 1.5 kg
Perm. ambient -20 °C to +60 °C D-GF 150-MB
temperature
Installation DIN-rail TS 35 Display Text display of status, program
step and errors
Threshold setting 0 ... 9 Data output Direct Modbus port
Pre-purge 30 s ... 20 min

15
D-AM 150

Display module ©DURAG GROUP

Extension module for the


D-GF 150 automatic firing device
with functions ranging from first
out annunciator to plain text dis-
play up to fieldbus communication

D-AM 150

Features Functional description Design

●● Plain text display for the burner control The D-AM 150 display module upgrades the ●● Device for assembling onto TS 35 DIN-rail
D-GF 150 burner control D-GF 150 with
●● Initial value indicator with 24 inputs in three Additional equipment
groups ●● A plain text display (LCD) for showing the
●● Fault memory current program cycle of the burner control ●● Chip card for data storage
●● Text editor for plain text display as well as the remaining run-time. and parameterisation
●● Output relay for control via Fieldbus ●● The supported user displays include: (D-AM 150 CC)
●● Operational hours counter - Flame signal
●● Cycle counter - Error message
●● Chip card for ease of programming - Operational hours of the burner
●● Fieldbus communication (MODBUS-RTU) for - Burner cycles
up to 32 devices - Date and time
●● Can be combined with D-GF 150 as well as ●● A first out annunciator for the continuous
D-GF 150-MB monitoring of all connected limiters and
monitor chains. Should the system be shut
Applications down, the position in which chain the
●● Chemical industry shutdown is performed is stored.
●● Refineries ●● A MODBUS interface for outputting status
●● Cement plants and process information for the burner and
●● Waste incinerators D-GF 150 burner control.
●● Steam generators
●● Heating plants

Certifications ©DURAG GROUP

●● DVGW Digital display


D-ZS 087-20
●● UL 372
Display module D-AM 150 Burner control D-GF 150

Flame sensor
D-LE 603

second
flame sensor

Operational mode Intermittent operation, continuous Installation DIN-rail TS 35


operation, 72-hour operation
without permanent supervision Dimensions 170x130x114 mm (WxHxD)
Safety First our annunciator: fail-safe Weight approx. 1.2 kg
Electrical 115/ 230 VAC, 50/ 60 Hz Display Alpha-numeric LCD display
connection
Protection IP20 Data output Modbus RTU
Perm. ambient -20 °C to +60 °C
temperature

16
D-GF 75

Burner control ©DURAG GROUP

Self-monitoring and fail-safe burner


control for the control of gas and oil
burners as well as combined gas/oil
burners of any capacity

D-GF 75-10

Features Functional description Design

●● Controlling and monitoring of gas and oil Generally used fuel types and burners require ●● Enclosure for DIN-rail installation
burners of any capacity certain synchronised program cycles and safety
●● Suitable for intermittent operation margins for burner start-up which are controlled Models
(D-GF 75-10) and continuous operation and monitored electronically with the burner
(D-GF 75-20) control: ●● D-GF 75-10
●● Integrated ionisation flame monitor ●● The pre-purge of the boiler with optional air for intermittent operation
●● Input for external flame monitor pressure check – Operation with ionisation electrode
●● Adjustable pre-purge time ●● The ignition of the burner – Connection for external flame monitors (for
●● Adjustable safety times ●● The fuel valves continuous operation) e.g. DURAG D-LX
●● Optinional recycling after flame loss in opera- ●● Flame monitoring 100 compact flame monitor or the combi-
tion position nation of D-UG 120 with a D-LE 103 flame
After the release of the ignition sequence by a sensor.
Applications thermostat for example, the device performs a ●● D-GF 75-20
check of ambient light. If no flame is detected, for continuous operation
●● Chemical industry the ignition sequence starts. If no flame forms – Operation with ionisation electrode
●● Refineries during the ignition sequence or if it is extin- – Connection for external flame monitors
●● Cement plants guished whilst the burner is in operation, an (for continuous operation) e.g. DURAG
●● Waste incinerators interlock is activated. D-LX 100 compact flame monitor or the
●● Steam generators combination of D-UG 120 with a D-LE 103
●● Heating plants flame sensor

Certifications

●● DVGW
●● EAC
©DURAG GROUP

Ionisation electrode
(D-GF 75-10 and
D-GF 75-20)
D-GF 75-10 Burner control

Operational mode D-GF 75-10: Start-up safety 3, 5, 10 or 15 s


Intermittent operation time
D-GF 75-20: Intermittent operation
and continuous operation Pre-purge time 0, 30, 60 or 120 s

Safety Self-monitoring and fail-safe Operational safety 1, 2, 3 or 5 s


time
Electrical 115/ 230 VAC, 50/ 60 Hz Flame intensity 0 ... 50 µA
connection
Protection IP20 Display LED
Perm. ambient -20 °C to +60 °C Dimensions 91x103x118 mm (WxHxD)
temperature
Flame sensor - Ionisation electrode Weight approx. 1 kg
- External flame monitor
Installation DIN-rail TS 35

17
D-HG 55

Electronic ignition ©DURAG GROUP

transformer
The D-HG 55 electronic ignition
transformer is suitable for the
ignition of gases and liquid fuels
in small burners

D-HG 55-10

Features Functional description Models

●● Ignition of oil and gas A capacitor is charged up in the electronic igni- ●● D-HG 55-10
●● High-performance and reliable ignition tion transformer. Once the required energy level Electronic ignition transformer for connec-
●● Simple to use and install has been reached, a non-wearing electronic tion to an external ignition electrode
●● Robust enclosure for industrial use switch (thyristor) triggers a spark discharge at ●● D-HG 55-11
●● Maintenance-free because no wearing parts the ignition tip. Electronic ignition transformer for connec-
●● 100 ignition sparks/second with a mains fre- tion to an external ignition electrode with
quency of 50Hz, 120 ignition sparks/second The D-HG 55-11 and -21 electronic ignition the option of connecting the electrode to an
with a mains frequency of 60Hz transformers allow the use of the electrode as ionisation flame monitor
●● Suitable as “Ignitor Class 3 Special“ in accord- a common ignition and ionisation electrode for ●● D-HG 55-20
ance with NFPA 85 flame monitoring. The electrode is automatically Electronic ignition transformer with attached
switched over after powering off the ignition. ignition electrode
Applications The ionisation current may be tapped off at a ●● D-HG 55-21
terminal. The HEGWEIN AAL 75 ionisation flame Electronic ignition transformer with attached
●● Chemical industry monitor is suitable as a flame monitor. ignition electrode with the option of con-
●● Refineries necting to an ionisation flame monitor
●● Cement plants
●● Waste incineration
●● Steam generators
●● Heating plants

Certifications

●● EAC
©DURAG GROUP

Electronic Electronic ignition transformer with


ignition transformer attached igniton electrode
D-HG 55-10 D-HG 55-20
D-HG 55-11 Connection for ionisation D-HG 55-21
flame monitor
(only D-HG 55-11)

Length 145 to 1104 mm


Ø 15mm
Power supply
connection

Ignition electrode
Connection for Power supply
ionisation flame connection
monitor
(only D-HG 55-21)

Electrical 115/ 230 VAC, 50/ 60 Hz Perm. ambient -20 °C to +60 °C


connection temperature
Power 15 VA Protection IP55
consumption
Ignition voltage 5000 V Dimensions 100x100x80 mm (LxWxD)
(without ignition electrode)
Duty cycle max 300 s (Duty cycle 50%) Weight approx. 0.7 kg

18
D-HG 400

High energy ignition


The high energy ignition devices of
©DURAG GROUP
the D-HG 400 and D-HG 500 series
are suitable for the ignition of gas
or liquid fuels in industrial burners
of any capacity

D-HG 400-51 D-HG 500-51

Features Function Models

●● Reliable ignition of gaseous fuels At the high energy igniters D-HG 400 and ●● D-HG ...-50
●● Ignition of liquid fuels, up to heavy D-HG 500 a high-voltage capacitor is discharged Compact set-up, electronics and ignition
oil grade 6 and a spark is created at the ignition lance‘s lance are one unit
●● Suitable as „Ignitor Class 3 Special“ in tip. The spark discharge is triggered by a ●● D-HG ...-51
accordance with NFPA 85 non-wearing switch (thyristor). Every spark Compact set-up as D-HG ... -50 with
●● Compact set-up with integrated produces –depending on the model – an push-button for manual ignition
ignition lance energy of up to 5,6 Joule at a maximum ●● D-HG ...-52
●● Separated set-up of ignition device and ignition frequency of 20 sparks per second. Compact set-up as D-HG ... -50 with
ignition lance for safe and hazardous areas separated connections for signalling and
●● Thyristor controlled and therefore non- Capacity types power supply
wearing electronic ●● D-HG ...-60
●● Ignition feedback signal via potential-free ●● D-HG 400 Separated set-up for safe areas: Electronic
relay output Ignition feedback signal via LED at the de- unit and ignition lance are connected by a
●● LED indication at device vice and potential-free relay output to the high voltage cable
●● Integrated protection and control control room, maximum ignition energy of ●● D-HG ...-61
functionalities 90 Joule at a maximum ignition frequency of Separated set-up as
20 sparks per second D-HG..-60 with push-button for manual
Applications ●● D-HG 500 ignition
Ignition feedback and status ●● D-HG ...-62
●● Chemical industry signal via LEDs at the device and Separated set-up as
●● Refineries potential-free relay outputs to the control D-HG..-60 with separated connections for
●● Cement plants room, maximum ignition energy of signalling and power supply
●● Waste incinerators 112 Joule at a maximum ignition ●● D-HG ...-..Ex
●● Power plants frequency of 20 sparks per second Separated set-up for potentially explosive
●● Steam generators ●● D-HG 550 atmospheres 1&21 (ATEX)
●● Claus plants As D-HG 500 but with the ●● Optional
additional possibility for customizing of Customized and project specific versions
Certifications parameters and optional available control with flexible ignition lances for tilting
functionalities (via software D-ESI 100 by burners
●● ATEX/ IECEx user or DURAG-Service)
●● EAC

Electrical 115 VAC/ 230 VAC, 48-60 Hz Perm. ambient D-HG 400: -20 °C to +60 °C
connection temperature D-HG 5x0: -40 °C to +80 °C
Power 200 VA Display LEDs (Ignition feedback,
consumption status (only D-HG 5x0))
Ignition voltage 1500 V Protection IP65 (D-HG ..-5x/-6x)
IP66 (D-HG ..-7xEx/-9xEx)
Inition energy/ D-HG 400: 90 J Dimension 108x188x237 (BxHxT)
second (max) D-HG 5x0: 112 J (D-HG-5x/6-6x)
Ignition frequency Max 20 sparks/ second Weight (appr., D-HG ...-5x/6x: 4,5 kg
without ignition D-HG ...-7xEx: 16 kg
Power on time 50 % lances) D-HG ...-9xEx: 18 kg

19
D-ZL ...

D-ZL 500 - directly mounted at D-HG ... -50/ -51/ -52


Ignition lances 591 mm
For the connection to the high
energy ignition devices of the
D-HG 400 and D-HG 500 series in
order to ignite gas or liquid fuels in LZL

industrial burners of any capacity –


also in hazardous areas

©DURAG GROUP

Features Length ignition Min 0,7 m, max 15 m Weight ignition 1,6 kg/m at Ø 22mm
lance LZL (grid dimension: 100 mm) lance

●● Flexible customization for specific Diameter ignition Standard: 22 mm Operational life of 10⁶ sparks
lance Others on request ignition tip
installation conditions by various combina-
tion of components Max temperature Normal temperature (NT):
ignition tip 600 °C, briefly 800 °C
●● Easily replaceable ignition tips – available as High temperature (HT):
normal or high temperature-proof models Up to 1000 °C
●● Special igntion tips for the ignition
of HFO or at high pressure
●● Ignition lance lenghts up to 15 meter
●● Up to 50 m distance can be overcome D-ZL 521- seperated ignition lance for D-HG ...-60/ -61/ -62
by using robust high voltage cables – with-
out any loss of performance! High voltage cable Lance 591 mm
●● Compatible with retractions units D-VE 500

Applications

●● Chemical industry
●● Refineries
●● Cement plants Length ignition Min 0,7 m, max 15 m Weight ignition 1,6 kg/m at Ø 22mm
lance LZL (grid dimension 100 mm) lance
●● Waste incinerators
Length high Min 3 m, max 50 m Weight high 0,5 kg + 0,5 kg/m
●● Power plants voltage cable voltage cable
(grid dimension 5 m)
●● Steam generators LHV
●● Claus plants Diameter ignition Standard: 22 mm Operational life of 10⁶ sparks
lance Other on request ignition tip
Certifications Max temperature Normal temperature (NT): Cable take-off At side of device: 0°/ 90°
ignition tip Up to 600 °C, briefly 800 °C At side of lance: 0°/ 90°
●● ATEX/ IECEx High temperature (HT):
Up to 1000 °C
●● EAC

D-ZL 441Ex - connectable to D-HG ...-..Ex for hazardous areas

High voltage cable Lance 591 mm

Ø 22

LHV

©DURAG GROUP

Length ignition Min 0,7 m, max 15 m Weight ignition 1,6 kg/m at Ø 22mm
lance LZL (grid dimension: 100 mm) lance
Length high Min 3 m, max 50 m Weight high 0,5 kg + 0,5 kg/m
voltage cable (grid dimension: 5 m) voltage cable
LHV
Diameter ignition Standard: 22 mm Operational life of 10⁶ sparks
lance Other on request ignition tip
Max temperature Normal temperature (NT): Cable take-off At side of lance: 0°/ 90°
ignition tip Up to 600 °C, briefly 800 °C
High temperature (HT):
Up to 1000 °C
Ex protection II 2G Ex d IIC T6, T5, T4 Gb Perm. ambient -40 °C to +80 °C
(ATEX/IECEx) II 2D Ex tb IIIC T80, 95, 130 °C Db IP65 temperature

20
D-VE 500

Pneumatic retraction
unit
Pneumatic retraction unit for the
insertion and retraction of ignition
lances and ignition devices D-VE 500
(with D-HG 500-50)

©DURAG GROUP

Features Functional description Accessories

●● Automatic insertion and retraction of Correct positioning of the ignition tip at the ●● Terminal box
ignition lances edge of the fuel/ air mixture is a pre-requisite for for connecting solenoid valve and
●● Compressed air drive reliable ignition of a burner with a high-energy limit switch:
●● Direction change with solenoid valve ignition device. But temperatures in the optimal - IP66 (normal environment)
●● Speed control ignition zone are usually much too high during - IP65 (explosion protected model)
●● Non-contact limit switch burner operation, resulting in possible damage Ex-protection: II 2 G Ex e ia IIC T6
●● For use with ignition device to the ignition tip. ●● Weather protection hoods
D-HG 400-5x/ 5x0-5x or ignition The pneumatic retraction mechanism assumes - for 300 mm stroke
lances ZL 441Ex/ 521 the task of positioning the ignition tip precisely - for 400 mm stroke
●● Available stroke lengths: 300, 400, 500 and into the ignition zone of the burner and retract- - for 500 mm stroke
600 mm ing it again after successful ignition. - for 600 mm stroke
●● Pressure-tight and/ or explosion protected
models also available
●● Operational overpressure up to 10 bar

Applications

●● Chemical industry
●● Refineries
●● Cement plants
●● Waste incinerators
●● Steam generators
●● Heating plants
●● Claus plants

Spray angle
Certification Spray cone

●● EAC Oil lance

●● ATEX

Ignition tip

optimal
ignition
position

©DURAG GROUP

Max perm. 10 bar Electrical 24/ 48 VDC or 115/ 230 VAC


pressure of connection
instrument air
Max ambient -5 °C to +40 °C, others on request Protection IP65
temperature
Sheer force at 1870 N Display LED
6 bar
Retraction force at 1682 N Ex- protection limit II 2 G Ex ia IIC T4...T6
6 bar switch NAMUR
(optional)
Weight (approx.) 300 mm stroke: 9.0 kg
400 mm stroke: 11.0 kg Ex-solenoid valve II 2 GD Ex m II T5
500 mm stroke: 12.5 kg (optional)
600 mm stroke: 14.0 kg

21
Housings

D-BT 0... ©DURAG GROUP

19” rack for front panel mounting of


D-UG 660 control unit Models D-BT 043

●● For switching cabinet mounting in the inner ●● D-BT 013 ●● D-BT 023 ●● D-BT 043
area (IP00), e.g. hinged frame assembly Rack for one D-UG 660 con- Rack for two D-UG 660 con- Rack for four D-UG 660 con-
●● Cable connection via 48-pin screwed multi- trol unit, 3RU, 24HP trol units, 3RU, 42HP trol units, 3RU, 84HP
point socket connector ●● Dimensions ●● Dimensions ●● Dimensions
●● Terminal connection from rear 178x132,5x213 mm (WxHxD) 269x132,5x213 mm (WxHxD) 482x132,5x213 mm (WxHxD)
●● Weight 0.9 kg ●● Weight 1.45 kg ●● Weight 2.3 kg

©DURAG GROUP
D-BT 660...
B19”-rack for rear panel mounting
of D-UG 660 control unit Models D-BT 660/2

●● For switching cabinet mounting in the inner ●● D-BT 660 ●● D-BT 660/2 ●● D-BT 660/4
area (IP00), e.g. rear panel assembly Rack for one D-UG 660 con- Rack for two D-UG 660 con- Rack for four D-UG 660 con-
●● Cable connection via connection terminals trol unit, 3RU, 24HP trol units, 3RU, 42HP trol units, 3RU, 84HP
●● Clamp connection from front ●● Dimensions ●● Dimensions ●● Dimensions
171x149,5x215mm (WxHxD) 263x149,5x215 mm (WxHxD) 476x149,5x215 mm (WxHxD)
●● Weight 0.8 kg ●● Weight 1.25 kg ●● Weight 2.1kg

D-UG 660 G66 ©DURAG GROUP

Models
19” field plastic housing,
for D-UG 660 control unit ●● D-UG 660 G66 ●● D-UG 660 G66/2
Enclosure for one D-UG 660 Enclosure for two D-UG 660
●● For wall mounting in the outdoor area control unit control units D-UG 660 G66/2
●● Cable connection via terminals in separate ●● Dimensions ●● Dimensions
terminal box 135x149,5x250 mm (WxHxD) 340x236x275 mm (WxHxD)
●● Protection IP55 ●● Weight 1.5 kg ●● Weight 3.65kg

D-ZS 140/ 141 ©DURAG GROUP

Terminal box for


D-LE... flame ­sensor and
D-LX... compact flame monitor
Models
●● Protection IP65
●● D-ZS 140 8-pole version for ●● D-ZS 141 ●● D-ZS 141-12
safe environments 8-pole version for potentially 12-pole version for
●● Dimensions 105x105x66 mm explosive a­ tmospheres II 2G D-LX 200/720
(WxHxD), Weight 0.35 kg Ex e II T5/T6
●● D-ZS 140-12 12-pole version ●● Dimensions 110x75x55 mm
for D-LX 200/720 (WxHxD), Weight 0.4 kg

D-ZS 087-20
©DURAG GROUP
Digital display for displaying the
flame signal
●● For optimal alignment of flame sensor with
the ball flange and/ or for displaying the
­configuration of flame sensor and switching ●● Dimensions D-ZS 087-20
device 157x87x30 mm (WxHxD)
●● Display of the flame signal (pulse rate) ●● Weight 0.3 kg
●● Storing of minimum and maximum pulse
rate values
●● Voltage supply via the flame sensor

22
Accessories

D-ZS 129-30/ -40 Models


LED bar graph display for the flame ●● D-ZS 129-30 ●● D-ZS 129-40
intensity Electrical connection 24 VDC Power supply 230 VAC
●● Dimensions ●● Dimensions
●● Installation in 19“ frame 15.2x128.4x107.5 mm 15.2x128.4x107.5 mm
●● 3RU/ 3HP (WxHxD) (WxHxD)
●● Input 0/4 ... 20 mA ●● Weight 0.2 kg ©DURAG GROUP
●● Weight 0.2 kg
D-ZS 129-30

D-ZS 077-10
©DURAG GROUP

UV-C test light source for the func-


tional test of flame sensors
●● For the functional test of flame sensor mod-
els D-LE 103 UL, D-LE 603 UH/US and com- ●● Dimensions
D-ZS 077-10
pact flame monitor D-LX 100 UL 120x80x81.7 mm (WxHxD)
●● Electrical connection 230 VAC/ 50 Hz ●● Weight 0.65 kg

D-ZS 093 ©DURAG GROUP

Combined test light source for the


UV-A, UV-B and IR spectral range
●● For the functional test of flame sensor mod-
els D-LE 603 UA/UAF/IS/IG/ISE/ISO, D-LE 701 D-ZS 093
UA/UAF/IS/IGA, D-LE 703 UA/UAF/ IS/IG, ●● Dimensions
D-GT 800 UA/UAF, as well as compact flame 120x80x81.7mm (WxHxD)
monitors D-LX 100 UA/UAF/IS/IG and D-LX ●● Weight 0.65 kg
200 UA/UAF/IG
●● Electrical connection 230 VAC/ 50Hz

D-LX 200 Test kit ©DURAG GROUP

For software supported tests


of the compact flame monitors
D-LX 200/ 720, including
printed output of protocols for
documentation
●● Set containing a test light source and relay
tester, software D-LX 200 InformationCentre
●● Mobile use, uncluding robust transport case
●● Electrical connection 100-240 VAC/ 50-60 Hz
D-LX 200 Test kit

D-ZS 118 ©DURAG GROUP

Optical adjustment aid for align-


D-ZS 118
ment of the swivel mount on the ●● Dimensions L=200 mm
Ø=87 mm
sighting tube
●● Weight 0.5 kg

D-ZS 130 ©DURAG GROUP

Fail-safe relay card

●● Installation in 19“ rack/ enclosure


●● 3RU/ 10HP
●● Electrical connection 24VDC ●● Dimensions D-ZS 130
●● Protection IP00 50.5x128x190.5 mm (WxHxD)
●● Weight 0.25 kg

23
Accessories

D-NG 24/05 ©DURAG GROUP

Power supply for D-UG 120,


D-LX 100 or D-LX 200
●● To supply two D-UG 120 switching devices
or D-LX 100 and D-LX 200/720 compact
flame monitors ●● Dimensions D-NG 24/05

●● DIN-rail installation 70x75x118 mm


●● Input voltage 115/ 230 VAC, output voltage (WxHxD)
(unregulated) 24 VDC/ 0.5 A ●● Weight 0.55 kg
●● Protection IP20

D-ZS 033 ©DURAG GROUP

Swivel mount for flexible alignment


of a flame sensor at the sighting
tube of a burner
●● Tmax = 180 °C Models

●● D-ZS 033 I ●● D-ZS 033 III


for standard flame sensor for Ex-flame sensor, G 1“ thread
G 1¼“ thread ●● Dimensions L=160, Ø=115 mm
●● Dimensions L=90, Ø=115 mm Weight 3.4 kg
●● Weight 1.6 kg ●● Other models on request

D-ZS 114 ©DURAG GROUP

Separable screw pipe connection


for the installation of a
D-ZS 114
D-LE 603.../94 Ex or a
D-LE 603.../95 Ex ●● Dimensions
on a standard port of a D-LE 603... L=86, Ø=46 mm
flame sensor ●● Weight=400 g
●● Thread G 1“

D-ZS 117/ D-ZS 117 HT ©DURAG GROUP

Thermal isolator with electrical


insulation for the isolation of the D-ZS 117 I
heat transfer and/ or for electrical Models
isolation between sighting tube and ●● D-ZS 117 I ●● D-ZS 117 III
flame sensor for standard flame sensor for Ex-flame sensor, G 1“ thread
G 1¼“ thread ●● Dimensions L=56, Ø=51 mm
Features ●● Dimensions L=56, Ø=51mm Weight 0.05 kg
●● Weight 0.05 kg ●● High-temperature model on request
●● Rigid up to 120 °C, HT up to 180 °C ●● Other models on request

D-ZS 133 ©DURAG GROUP

Ball valve for closing the sighting


tube Models
D-ZS 133 I
Recommended when removing the flame s­ ensor ●● D-ZS 133 I ●● D-ZS 133 III
at increased furnace pressure for standard flame sensor for Ex-flame sensor, G 1“ thread
●● Tmax = 150 °C G 1¼“ thread ●● Dimensions L=174, Ø=46 mm
●● Dimensions L=216, Ø=58 mm ●● Weight 0.9 kg
●● Weight 1.4 kg ●● Other models on request

24
Requirements and Certifications
The DURAG GROUP, synonymous with a demand ●● Factory Mutual Research Cooperation (FM) Combustion technology stipulates that fuel
for high quality standards, has been ISO 9001 ●● EAC may not enter the combustion chamber if safe
certified for years and has fully implemented ●● ATEX combustion can not be guaranteed. If no flame
its requirements. DURAG products are manu- ●● Underwriters Laboratories Inc. (UL) is detected, the fuel supply must be closed, often
factured and tested in accordance with both ●● Underwriters Laboratories for Canada (C-UL) within 1s. European and international regula-
­European and international standards such as: tions therefore specify a high degree of fail
safety and reliability for equipment deployed.
●● APAVE International (France) Monitoring of the flame must also be unaf-
●● Australian Gas Association (AGA) fected by the construction of the furnace and its
●● Deutsche Vereinigung des Gas- und ­operational mode.
Wasserfaches e.V. (DVGW)

Requirements for flame monitoring and burner control (selection)

Europe USA Canada

Steam Boilers EN 12952 Water Tube Boilers NFPA 85 Boiler and Combustion Systems
EN 12953 Shell Boilers Hazards Code

Firings EN 746 Industrial Thermoprocessing NFPA 86 Standard for Ovens and


Equipment Furnaces
2009/142/EG EC Gas Appliance Directive

Burner UL 726 Oil-Fired Boiler ­Assemblies


UL 795 Commercial-Industrial Gas
Heating Equipment

Flame Monitors and EN 298 Automatic burner control UL 372 Primary Safety Controls for CSA 22.2. Combustion
Automatic Burner systems for burners and Gas- and Oil-Fired Appliances No. 199- Safety Controls
Control Devices appliances burning gaseous FM Class Combustion Safeguards M89 and Solid-State Igniters
and liquid fuels 7610 and ­Flame Sensing Systems for Gas- and Oil Burning
EN 60730-2-5 Automatic Electrical ­Equipment
Controls for Household Use and
Similar Use

Functional safety IEC 61508

(7)

25
Questionnaire for Selection of Flame Monitors (1/2)

Customer/ Partner Date

Contact person Preferred contact method

Project Tel. Email

Plant Details

Plant type

Load of individual burners MW

Burner layout Front Boxer Corner


Ceiling Floor Others

Number of burners at plant pcs

Alignment of burners pcs vertical pcs horizontal

Distance between burners m vertical m horizontal


Dimensions of furnace
(LxWxH) m x m x m

m m

Sighting tube length m Sighting tube diameter mm

Burner type Igniter Pilot burner Main burner


Start-up/ heat-up burner Fluidized bed burner Others

Fuels Gas Coal Oil Others


For oil: type of
Steam Air Pressure Others
atomization
Operational mode Intermittent Continuous

Combustion Low NOx Exhaust recirculation

Required accessory Burner control Ignition device

Environmental Conditions
Ambient
Minimum °C Maximum °C Average °C
temperature
Area of installation Indoor Outdoor

DVGW ATEX IECEx FM


UL AGA GOST Others

Attached Documents

Fuel composition Furnace/ burner drawing


Climate conditions Others

26
Questionnaire for Selection of Flame Monitors (2/2)

Flame Monitor Details

Make Type

Flame Monitor Requirements

Flame monitor design Flame sensor with separate control unit

Fiber optic version Yes No

m rigid length

Planned sensor type UV IR UV&IR

Expected wave length nm to nm

Monitoring mode Burner selective Fuel selective Furnace monitoring


Pilot burner selective

FFDT (safety time) 1s 2s 3s 5s

Analog output 0–20 mA 4–20 mA

Supply voltage V DC AC Hz

Minimum IP-Class Flame sensor IP Control unit IP

Ex-Protection Flame Sensor/ Compact Flame Monitor Yes No


Zone Please specify the minimum requirement for Ex-protection (zone,
ATEX II Ex II T category, type of protection, group, gas group, temperature class)
Please specify the minimum requirement for Ex-protection (class,
NEC 500 Class Division Group T division, gas group, temperature class)

Ex-Protection Control Unit Yes No

Viewing window Yes No


Please specify the minimum requirement for Ex-protection (zone,
ATEX Zone II Ex II T category, type of protection, group, gas group, temperature class)
Please specify the minimum requirement for Ex-protection (class,
NEC 500 Class Division Group T division, gas group, temperature class)

Installation Details

Cable gland Plug

Sighting tube connection G NPT 1“ 1¼“ Others

Axial <20° <90° ° Opposite


Others

Optional accessories Swivel Mount Thermal/ electr. insulator Ball valve Others

Mounting of control unit 19"-rack frame for 19"-rack frame for Wall enclosure Wall enclosure
front panel mounting rear panel mounting plastic metal
Number of control units per rack/ enclosure pcs
Additional Information

27
DURAG GmbH A Brand of A Brand of
Kollaustraße 105 DURAG GmbH DURAG GmbH
22453 Hamburg, Germany
Tel. +49 40 55 42 18-0
Fax +49 40 58 41 54
E-Mail: info@durag.de

DURAG data systems GmbH A Brand of DURAG Siena do Brasil Ltda


Kollaustraße 105 DURAG data systems GmbH Rua Vinte e Dois de Agosto, 66
22453 Hamburg, Germany Branch Office Austria Diadema - SP
Tel. +49 40 55 42 18-3000 Lastenstraße 36, City Tower 2 09941-530 Brazil
Fax +49 40 55 42 18-3099 4020 Linz, Austria Tel. +55 11 4071-5050 r.28
E-Mail: info@durag-data.de Tel. +43 732 60 99 60-0 Fax +55 11 4077-1718
Fax +43 732 60 99 60-4 E-Mail: info@duragsiena.com.br
E-Mail: office@utas.at

Hegwein GmbH SMITSVONK Holland B.V. GRIMM Aerosol Technik


Am Boschwerk 7 P.O. Box 180, 2700 AD Zoetermeer GmbH & Co. KG
70469 Stuttgart Goudstraat 6, 2718 RC Zoetermeer Dorfstraße 9
Germany Netherlands 83404 Ainring, Germany
Tel. +49 711 135 788-0 Tel. +31 79 361 35 33 Tel. +49 8654 578-0
Fax +49 711 135 788-5 Fax +31 79 361 13 78 Fax +49 8654 578-35
E-Mail: info@hegwein.de E-Mail: sales@smitsvonk.nl E-Mail: info@grimm-aerosol.com

DURAG Sales and Marketing DURAG Brazil DURAG France S.a.r.l. DURAG, Inc.
GmbH & Co. KG DURAG Siena do Brasil Ltda 147 avenue Paul Doumer 1355 Mendota Heights Road
Kollaustraße 105 Rua Vinte e Dois de Agosto, 66 92500 Rueil Malmaison Suite 200
22453 Hamburg, Germany Diadema - SP France Mendota Heights
Tel. +49 40 55 42 18-0 09941-530 Brazil Tel. +33 1 412 904 60 MN 55120, USA
Fax +49 40 58 41 54 Tel. +55 11 4071-5050 r.28 Fax +33 1 412 904 68 Tel. +1 651 451-1710
E-Mail: info@durag.de Fax +55 11 4077-1718 E-Mail: info@durag-france.fr Fax +1 651 457-7684
E-Mail: info@duragsiena.com.br E-Mail: durag@durag.com

DURAG India Instrumentation DURAG Instrumentation DURAG Italia S.r.l. DURAG Japan Office
Private Limited (Shanghai) Co., Ltd. Via Carlo Panseri, 118 c/o TMS Planning Inc.
#27/30, 2nd Main Road Room 706, Dibao Plaza, No. 3998 CIM uffici, P. secondo 291-2 Umena, Mishima-shi
Industrial Town, Rajajinagar Hongxin Rd., Minhang District 28100 Novara Shizuoka-ken
Bengaluru 560 044, India Shanghai, 201103 PR China Italy 411-0816 Japan
Tel. +91 80 2314 5626, 2301 1700 Tel. +86 21 60732979-200 Tel. +39 0321 679569 Tel. +81 55 977 3994
©DURAG GROUP 05/2016 · Subject to change without notice

Fax +91 80 2314 5627 Fax +86 21 60732980-205 Fax +39 0321 474165 Fax +81 55 977 3994
E-Mail: info@duragindia.com E-Mail: info@durag-cn.com E-Mail: info@durag.it E-Mail: info@durag.jp

DURAG Korea Office DURAG Middle East (Branch) DURAG RUSS OOO DURAG UK GmbH
RM #1131, Manhattan Building Dubai Airport Free Zone Andropova avenue 18/6 Bretby Business Park, Ashby Road
36-2, Yeouido-Dong 5 West Wing, Office 124 Office 5-09 Burton-on-Trent, Staffordshire
Yeongdeungpo-Gu, Seoul Dubai, UAE 115432 Moscow DE15 0YZ
Korea P.O. Box  371555 Russia Great Britain
Tel. +82 2 761 8970 Tel. +971 4260251 0 Tel. +7 499 4180090 Tel. +44 1283 553 481
Fax +82 2 761 8971 E-Mail: dme@durag.de Fax +7 499 4180091 Fax +44 1283 553 482
E-Mail: info@durag-group.co.kr E-Mail: info@durag-group.ru E-Mail: durag.uk@durag.de

DURAG Branch North DURAG Branch East DURAG Branch South DURAG Branch West
Kollaustraße 105 Halsbrücker Straße 34 Weidenweg 16 An der Pönt 53a
22453 Hamburg, Germany 09599 Freiberg, Germany 73087 Bad Boll, Germany 40885 Ratingen, Germany
Tel. +49 40 55 42 18-0 Tel. +49 3731 30 04-0 Tel. +49 7164 912 25-0 Tel. +49 2102 74 00-0
Fax +49 40 58 41 54 Fax +49 3731 30 04-22 Fax +49 7164 912 25-50 Fax +49 2102 74 00 28
E-Mail: durag-nord@durag.de E-Mail: durag-ost@durag.de E-Mail: durag-sued@durag.de E-Mail: durag-west@durag.de

Credits: (1) shutterstock.com: cpaulfell, (2) lidian Neeleman, (3) M. Dogan, (4) Cylonphoto, (7) Ian Bracegirdle,
(5) ©DURAG GROUP, (6) dreamstime.com: José Marafona www.durag.com

smart solutions for combustion and environment

You might also like