You are on page 1of 28

L&T Construction

Water & Renewable Energy, EDRC-WET

DOCUMENT NO. DATE


PROJECT:
18-Sep-2018
DESIGNED CHECKED PAGE
TITLE
YB JSR

Design of Chequered plate-300mm in Length

Check for chequered plate (As a whole section)

400

202
6 26.9
679.04

100 x 10 Flat

Yield stress of steel, fy = 250 N/mm2

Width of chequered plate, Wc = 400 mm

IS:800 1984 Effective width of flange = 16 x Tp x 2 + Wf = 16 x 6 x 2 + 10 = 202 mm

Cl. 3.5.2 Thickness of chequered plate, Tp = 6 mm

Height of flat, Th = 100 mm

Thickness of flat, Wf= 10 mm

Unit weight of steel = 78.5 kN/m2

Live load on plate = 1.5 kN/m2

Span of the plate = 1.15 m

Self weight of plate = 0.4 x 0.006 x 78.5 = 0.188 kN/m

Self weight of flat = 0.1 x 0.01 x 78.5 = 0.079 kN/m

Live load = 1.5 x 0.4 = 0.6 kN/m

Total Laod = 0.188 + 0.079 + 0.6 = 0.867 kN/m

Moment = 0.867 x 1.15^2 / 8 = 0.143 kNm

Area of the plate A1 = 202 x 6 = 1212 mm2

Area of the flat A2 = 10 x 100 = 1000 mm2

x1 =6 / 2 = 3 mm

x2 = 100 / 2 + 6 = 56 mm

y1 = (1212 x 3 + 1000 x 56) / (1212 + 1000) = 26.96 mm

# Sensitivity: Unclassified
L&T Construction
Water & Renewable Energy, EDRC-WET

DOCUMENT NO. DATE


PROJECT:
18-Sep-2018
DESIGNED CHECKED PAGE
TITLE
YB JSR

h for plate = 23.96 mm

h for flat = 29.04 mm

Ixx = 2376077.83 mm4

y2 = (100 + 6) - 26.96 = 79.04 mm

z = Ixx / y2 30061.713 mm3

Stress check = 143000 / 30061.713 = 4.757 N/mm2

OK < 165
5 W 𝑥 �4
Deflection = 384 EI 0.041 mm

< 6mm ok

Check for chequered plate (As a cantilever)

Self weight of plate = 0.006 x 78.5 = 0.471 kN/m2

Live load on plate = 1.5 kN/m2

Total load on plate = 1.971 kN/m2

1.971

200

Moment = 1.971 x 0.2^2 / 2 = 0.03942 kNm

Section modulus, Zxx = 1000 x 6 ^2 / 6 = 6000 mm3

Moment of inertia, Ixx = 1000 x 6 ^3 / 12 = 18000 mm4

Stress check, M/Zxx = 39420 / 6000 = 6.57 N/mm2

OK < 165
W𝑥� 4
Deflection = 8E I = 0.110 mm

Deflection permissible = L / 200 = 200/200 = <1mm

Check for bearing on the trench wall

Shear force on the wall = W x L / 2 = 0.867 x 1.15 / 2 = 0.50 kN

# Sensitivity: Unclassified
L&T Construction
Water & Renewable Energy, EDRC-WET

DOCUMENT NO. DATE


PROJECT:
18-Sep-2018
DESIGNED CHECKED PAGE
TITLE
YB JSR

IS:800 1984 Permissible bearing stress in steel, σp = 0.75 x fy = 187.5 N/mm2

Cl. 6.3

IS:456 2000 Permissible bearing stress in concrete, σbc = 0.25 x fck = 6.25 N/mm2

Cl. 34.4 Bearing length required over wall = V / (Min of σp & σbc x Wc)

=498.525 / ( 6.25 x 400) = 0.20 mm

0k < 40mm

40mm is the Bearing provided for chequered plate.

Weld size

The shear flow at any location is given by

q= VQ/I

where,

q = shear flow

I = 2nd moment of area also called moment of inertia of the section

Q = first moment of area, where the area is from free end upto the section, and it is taken

about the CG of the entire section

The first moment of area about CG is, Q1 = A1Y1

where,

A1 = area of the portion upto the section from free edge

Y1 = distance between centroid of area A1 and the centroid of the total section

X1 = 6/2= 3 mm

X2 = 100/2+6 56 mm

Y1 = 400x6x3+100x10x56/400x6+100x10 18.59 mm

Y2 = 100+6-18.59 = 87.41 mm

Area of the plate A1 = 202 x 6 = 1212 mm2

Area of the flat A2 = 10 x 100 = 1000 mm2

h for plate = 15.59 mm

# Sensitivity: Unclassified
L&T Construction
Water & Renewable Energy, EDRC-WET

DOCUMENT NO. DATE


PROJECT:
18-Sep-2018
DESIGNED CHECKED PAGE
TITLE
YB JSR

h for flat = 37.41 mm

Ixx = 1706051.73 mm4

400

202
6 18.5
9
87.41

100 x 10 Flat

Q= 400x6x18.59-3+100x10x87.41-100/2 74826.00 mm2

q= 0.498525x10^3x74826/1706051.73 21.86 N/mm

Size of weld required = q/0.7 fwd

21.86/110x0.7 = 0.28 mm

Provide 6 mm fillet weld

# Sensitivity: Unclassified
L & T CONSTRUCTION

Water & Effluent Treatment IC

DOCUMENT NO.

PROJECT: Sewerage system of Rourkela city East & West project

LE161034-C-WW-SW-DC-3020

DESIGNED CHECKED
TITLE Design calculation for Admin building with Electrical building
KSR JSR
Design of Chequered plate-Typical Length of 1250mm

Check for chequered plate=600mm Width

600

200 200
6 10
46
150 300 150

50 x 8 Flat 50 x 8 Flat

Yield stress of steel, fy = 250

Width of chequered plate, Wc = 600

IS:800 1984 Effective width of flange = 16 x Tp x 2 + Wf = 16 x 6 x 2 + 8 = 200

Cl. 3.5.2 Thickness of chequered plate, Tp = 6

Height of flat, Th = 50

Thickness of flat, Wf= 8

No of flats= 2

Unit weight of steel = 78.5

Live load on plate = 7.5

Span of the plate = 1.25

Self weight of plate = 0.6 x 0.006 x 78.5 = 0.283

Self weight of flat =2x 0.05 x 0.008 x 78.5 = 0.063

Live load = 7.5 x 0.6 = 4.5

Total Laod = 0.283 + 0.063 + 4.5 = 4.846

Moment = 4.846 x 1.25^2 / 8 = 0.946

# Sensitivity: Unclassified
L & T CONSTRUCTION

Water & Effluent Treatment IC

DOCUMENT NO.

PROJECT: Sewerage system of Rourkela city East & West project

LE161034-C-WW-SW-DC-3020

DESIGNED CHECKED
TITLE Design calculation for Admin building with Electrical building
KSR JSR
Area of the plate A1 =2 x 200 x 6 = 2400

Area of the flat A2 = 2 x8 x 50 = 800

x1 =6 / 2 = 3

x2 = 50 / 2 + 6 = 31

y1 = (2400 x 3 + 800 x 31) / (2400 + 800) = 10

h for plate = 7

h for flat = 21

Ixx = 557333.33

y2 = (50 + 6) - 10 = 46

z = Ixx / y2 12115.942

# Sensitivity: Unclassified
L & T CONSTRUCTION

Water & Effluent Treatment IC

DOCUMENT NO.

PROJECT: Sewerage system of Rourkela city East & West project

LE161034-C-WW-SW-DC-3020

DESIGNED CHECKED
TITLE Design calculation for Admin building with Electrical building
KSR JSR
Stress check = 946000 / 12115.942 = 78.0789475552

cl.6.4.2 of Average shear stess 0.4xfy 100


IS800:1984
< 100 OK
5 W 𝑥 �4
Deflection = 384 EI 1.38

Deflection permissible = L / 325 = =1.25 x 1000/325 OK <3.85

Check for chequered plate (As a cantilever)

Self weight of plate = 0.006 x 78.5 = 0.471

Live load on plate = 7.5

Total load on plate = 7.971

7.971

150

Moment = 7.971 x 0.15^2 / 2 = 0.08967375

Section modulus, Zxx = 1000 x 6 ^2 / 6 = 6000

Moment of inertia, Ixx = 1000 x 6 ^3 / 12 = 18000

Stress check, M/Zxx = 89673.75 / 6000 = 14.95

< 100 OK
W𝑥� 4
Deflection = 8E I = 0.14

Deflection permissible = L / 200 = 150/200 = <0.75mm

Check for chequered plate (As a Simply Supported)

# Sensitivity: Unclassified
L & T CONSTRUCTION

Water & Effluent Treatment IC

DOCUMENT NO.

PROJECT: Sewerage system of Rourkela city East & West project

LE161034-C-WW-SW-DC-3020

DESIGNED CHECKED
TITLE Design calculation for Admin building with Electrical building
KSR JSR
Self weight of plate = 0.006 x 78.5 = 0.471

Live load on plate = 7.5

Total load on plate = 7.971

7.971

300

Moment = 7.971 x 0.3^2 / 8 = 0.08967375

Section modulus, Zxx = 1000 x 6 ^2 / 6 = 6000

Moment of inertia, Ixx = 1000 x 6 ^3 / 12 = 18000

Stress check, M/Zxx = 89673.75 / 6000 = 14.95

< 100 OK
5 W 𝑥 �4
384 EI

# Sensitivity: Unclassified
L & T CONSTRUCTION

Water & Effluent Treatment IC

DOCUMENT NO.

PROJECT: Sewerage system of Rourkela city East & West project

LE161034-C-WW-SW-DC-3020

DESIGNED CHECKED
TITLE Design calculation for Admin building with Electrical building
KSR JSR
5 W 𝑥 �4
Deflection = 384 EI 0.23

Deflection permissible = L / 200 = 150/200 = <2mm

Check for bearing on the trench wall/Beam

Shear force on the wall = W x L / 2 = 4.846 x 1.25 / 2 3.03

IS:800 1984 Permissible bearing stress in steel, σp = 0.75 x fy = 187.5

Cl. 6.3

IS:456 2000 Permissible bearing stress in concrete, σbc = 0.25 x fck = 6.25

Cl. 34.4 Bearing length required over wall = V / (Min of σp & σbc x Wc)

=3028.75 / ( 6.25 x 600) = 0.81

OK < 40

50mm is the Bearing provided for chequered plate.

Weld size

The shear flow at any location is given by

q= VQ/I

where,

q = shear flow

I = 2nd moment of area also called moment of inertia of the section

Q = first moment of area, where the area is from free end upto the section, and it is taken

about the CG of the entire section

# Sensitivity: Unclassified
L & T CONSTRUCTION

Water & Effluent Treatment IC

DOCUMENT NO.

PROJECT: Sewerage system of Rourkela city East & West project

LE161034-C-WW-SW-DC-3020

DESIGNED CHECKED
TITLE Design calculation for Admin building with Electrical building
KSR JSR
The first moment of area about CG is, Q1 = A1Y1

where,

A1 = area of the portion upto the section from free edge

Y1 = distance between centroid of area A1 and the centroid of the total section

X1 = 6/2= 3

X2 = 50/2+6 31

Y1 = 600x6x3+50x8x31/600x6+50x8 5.80

Y2 = 50+6-5.8 = 50.20

Area of the plate A1 = 200 x 6 = 1200

# Sensitivity: Unclassified
L & T CONSTRUCTION

Water & Effluent Treatment IC

DOCUMENT NO.

PROJECT: Sewerage system of Rourkela city East & West project

LE161034-C-WW-SW-DC-3020

DESIGNED CHECKED
TITLE Design calculation for Admin building with Electrical building
KSR JSR
Area of the flat A2 = 8 x 50 = 400

h for plate = 2.80

h for flat = 25.20

Ixx = 269157.33

600

200 200
6 5.80
50.20

50 x 8 Flat 50 x 8 Flat

Q= 600x6x5.8-3+50x8x50.2-50/2 20160.00

q= 3.02875x10^3x20160/269157.33 226.85

Size of weld required = q/0.7 fwd

226.85/110x0.7 = 2.95

Provide 6 mm fillet weld

# Sensitivity: Unclassified
L & T CONSTRUCTION

Water & Effluent Treatment IC

DOCUMENT NO.

PROJECT: Sewerage system of Rourkela city East & West project

LE161034-C-WW-SW-DC-3020

DESIGNED CHECKED
TITLE Design calculation for Admin building with Electrical building
KSR JSR

# Sensitivity: Unclassified
DATE

9/18/2018

PAGE

N/mm2

mm

mm

mm

mm

mm

No

kN/m3

kN/m2

kN/m

kN/m

kN/m

kN/m

kNm

# Sensitivity: Unclassified
DATE

9/18/2018

PAGE

mm2

mm2

mm

mm

mm

mm

mm

mm4

mm

mm3

# Sensitivity: Unclassified
DATE

9/18/2018

PAGE

N/mm2

N/mm2

mm

kN/m2

kN/m2

kN/m2

kNm

mm3

mm4

N/mm2

mm

# Sensitivity: Unclassified
DATE

9/18/2018

PAGE

kN/m2

kN/m2

kN/m2

kNm

mm3

mm4

N/mm2

# Sensitivity: Unclassified
DATE

9/18/2018

PAGE

mm

kN

N/mm2

N/mm2

mm

update

# Sensitivity: Unclassified
DATE

9/18/2018

PAGE

mm

mm

mm

mm

mm2

# Sensitivity: Unclassified
DATE

9/18/2018

PAGE

mm2

mm

mm

mm4

mm2

N/mm

mm

# Sensitivity: Unclassified
DATE

9/18/2018

PAGE

# Sensitivity: Unclassified
L & T CONSTRUCTION

Water & Effluent Treatment IC

Design, Construction, Testing, Commissioning and Operation &


Maintenance of Infrastructure Works for Roads, Drains, DOCUMENT NO.
Culverts, Minor and Major Bridges, Water Supply, Sewerage,
PROJECT: Power systems Including Sewage and Common Effluent
Treatment Plants for Sector A, Phase - II in AURIC Bidkin
Industrial Area, Aurangabad, Maharashtra on EPC Basis
LNT-BD1A-EL-DC-4521
(Package - I)

DESIGNED
TITLE Design calculation for Zonal Substation Building-1
MKE
Design of Chequered plate-Typical Length of 2000mm

Check for chequered plate=300mm Width

300

200
6 16.5

75 x 8 Flat

Yield stress of steel, fy =

Width of chequered plate, Wc =

IS:800 1984 Effective width of flange = 16 x Tp x 2 + Wf = 16 x 6 x 2 + 8 =

Cl. 3.5.2 Thickness of chequered plate, Tp =

Height of flat, Th =

Thickness of flat, Wf=

Unit weight of steel =

Live load on plate =

Span of the plate =

Self weight of plate = 0.3 x 0.006 x 78.5 =

Self weight of flat = 0.075 x 0.008 x 78.5 =

# Sensitivity: Unclassified
Live load = 7.5 x 0.3 =

Total Laod = 0.141 + 0.047 + 2.25 =

Moment = 2.438 x 2^2 / 8 =

Area of the plate A1 = 200 x 6 =

Area of the flat A2 = 8 x 75 =

x1 =6 / 2 =

x2 = 75 / 2 + 6 =

y1 = (1200 x 3 + 600 x 43.5) / (1200 + 600) =

h for plate =

h for flat =

Ixx =

y2 = (75 + 6) - 16.5 =

z = Ixx / y2

Stress check = 1219000 / 14588.372 =

cl.6.4.2 of Average shear stess 0.4xfy


IS800:1984
5 W 𝑥 �4
Deflection = 384 EI

Deflection permissible = L / 325 = =2 x 1000/325

Check for chequered plate (As a cantilever)

Self weight of plate = 0.006 x 78.5 =

Live load on plate =

Total load on plate =

7.971

150

Moment = 7.971 x ^2 / 2 =

Section modulus, Zxx = 1000 x 6 ^2 / 6 =

# Sensitivity: Unclassified
Moment of inertia, Ixx = 1000 x 6 ^3 / 12 =

Stress check, M/Zxx = 89673.75 / 6000 =

W 𝑥 �4
Deflection = 8E I =

Deflection permissible = L / 200 = 150/200 =

Check for bearing on the trench wall/Beam

Shear force on the wall = W x L / 2 = 2.438 x 2 / 2 =

IS:800 1984 Permissible bearing stress in steel, σp = 0.75 x fy =

Cl. 6.3

IS:456 2000 Permissible bearing stress in concrete, σbc = 0.25 x fck =

Cl. 34.4 Bearing length required over wall = V / (Min of σp & σbc x Wc)

=2438 / ( 6.25 x 300) =

50mm is the Bearing provided for chequered plate.

Weld size

The shear flow at any location is given by

q= VQ/I

where,

q = shear flow

I = 2nd moment of area also called moment of inertia of the section

Q = first moment of area, where the area is from free end upto the section, and it is taken

about the CG of the entire section

The first moment of area about CG is, Q1 = A1Y1

where,

A1 = area of the portion upto the section from free edge

Y1 = distance between centroid of area A1 and the centroid of the total section

# Sensitivity: Unclassified
X1 = 6/2=

X2 = 75/2+6

Y1 = 300x6x3+75x8x43.5/300x6+75x8

Y2 = 75+6-13.13 =

Area of the plate A1 = 200 x 6 =

Area of the flat A2 = 8 x 75 =

h for plate =

h for flat =

Ixx =

300

200
6

75 x 8 Flat

Q= 300x6x13.13-3+75x8x67.87-75/2

q= 2.438x10^3x36456/683342.42

Size of weld required = q/0.7 fwd

130.07/110x0.7 =

Provide 6 mm fillet weld

# Sensitivity: Unclassified
DOCUMENT NO. DATE

NT-BD1A-EL-DC-4521 9/18/2018

CHECKED PAGE
JSR

250 N/mm2

300 mm

200 mm

6 mm

75 mm

8 mm

78.5 kN/m3

7.5 kN/m2

2m

0.141 kN/m

0.047 kN/m

# Sensitivity: Unclassified
2.25 kN/m

2.438 kN/m

1.219 kNm

1200 mm2

600 mm2

3 mm

43.5 mm

16.5 mm

13.5 mm

27 mm

940950 mm4

64.5 mm

14588.372 mm3

83.5597008357 N/mm2

100 N/mm2

< 100 OK

2.7 mm

OK <6.15

0.471 kN/m2

7.5 kN/m2

7.971 kN/m2

0.08967375 kNm

6000 mm3

# Sensitivity: Unclassified
18000 mm4

14.95 N/mm2

< 100 OK

0.14 mm

<0.75mm

2.44 kN

187.5 N/mm2

6.25 N/mm2

1.30 mm

OK < 40

ion, and it is taken

# Sensitivity: Unclassified
3 mm

43.5 mm

13.13 mm

67.87 mm

1200 mm2

600 mm2

10.13 mm

30.37 mm

683342.42 mm4

13.1
3
67.87

36456.00 mm2

130.07 N/mm

1.69 mm

# Sensitivity: Unclassified