EC9225A High Temperature

Acid Corrosion Inhibitor


Technifax TF–EC9225A

Laboratory Data
The corrosion rate data in the following tables was developed using coupons from N-80 pipe, coil
tubing, chrome 13 and chrome 2205 at various temperatures for 6 hours in 15%HCl, 28%HCl and
12%HCl/3%HF. The maximum allowable corrosion rate is 0.05lb/sq.ft per test period.

Table 1 – Corrosion rate test data at 175oF (79oC) for 6 hours

Coupon Acid PSIG Concentration Formic Acid Corrosion


Type Type Required (GPT)* (GPT)* rate
lb/sq.ft

N80** 15%HCl 3000 1 None 0.0017


N80 28%HCl 3000 3.5 None 0.0195
N80 12%HCl/3%HF 3000 1 None 0.0052

CT** 15%HCl 3000 2 None 0.0014


CT 12%HCl/3%HF 3000 1 None 0.0016

CR13** 15%HCl 3000 1 None 0.0012


CR13** 12%HCl/3%HF 3000 1 None 0.0295

CR2205** 15%HCl 3000 2 None 0.0385


CR2205 12%HCl/3%HF 3000 2 KI - 5PPT*** 0.0559
* Gallon per thousand gallons of acid (same as (liter/m3) )
** 4 hour testing time
*** Potassium iodide pound per thousand gallons of acid

Nalco Company
P.O. Box 87 Sugar Land TX ● 77487-0087 ● 1 281 263 7000
SUBSIDIARIES AND AFFILIATES IN PRINCIPAL LOCATIONS AROUND THE WORLD
©2006 Nalco Company
Table 2 – Corrosion rate test data at 275oF (135oC) for 6 hours

Coupon Acid PSIG Concentration Formic Acid Corrosion


Type Type Required (GPT)* (GPT)* rate
lb/sq.ft

N80 15%HCl 3000 5 20 0.0096


N80 28%HCl 3000 8 15 0.0185
N80 12%HCl/3%HF 3000 10 20 0.0115

CT 15%HCl 3000 5 15 0.0087


CT 28%HCl 3000 10 30 0.0172
CT 12%HCl/3%HF 3000 8 20 0.0223

CR13 15%HCl 3000 20 KI-30PPT** 0.0155


CR13 28%HCl 3000 30 KI-60PPT** 0.0437
CR13 12%HCl/3%HF 3000 30 KI-60PPT** 0.0452

CR2205 15%HCl 3000 25 CUI-50PPT*** 0.0121


CR2205 28%HCl 3000 40 CUI-50PPT*** 0.0189
CR2205 12%HCl/3%HF 3000 20 CUI-50PPT*** 0.0193

*Gallon per thousand gallons of acid (same as (liter/m3) )


**Potassium iodide pound per thousand gallons of acid
***Cuprous iodide pound per thousand gallons of acid

Table 3 – Corrosion rate test data at 350oF (177oC) for 6 hours

Coupon Acid PSIG Concentration Formic Acid Corrosion


Type Type Required (GPT)* (GPT)* rate
lb/sq.ft

N80 15%HCl 3000 10 EC9001A –2% 0.0300

CT 15%HCl 3000 10 EC9001A –2% 0.0223

CR2205 15%HCl 3000 10 EC9001A –2% 0.0330

3
*Gallon per thousand gallons of acid (liter/m )

Nalco Company
P.O. Box 87 Sugar Land TX ● 77487-0087 ● 1 281 263 7000
SUBSIDIARIES AND AFFILIATES IN PRINCIPAL LOCATIONS AROUND THE WORLD
©2006 Nalco Company

2
Testing Procedures
The above corrosion data was developed using industry approved NACE corrosion test cell
equipment and corrosion test autoclave equipment.

General sample preparation - The samples are prepared using a prescribed


concentration and type of acid solution, and prescribed concentration of EC9225A into a 100 ml
glass beaker. Depending upon the testing criteria, specified amount of an inhibitor aid may be
added to this mixture. The mixture will be swirled until it is thoroughly uniform. Then, a specified
metal coupon such as N-80, CT or chrome will be weighed and placed in this mixture. At this
point, depending upon temperature and pressure, either NACE cell or corrosion autoclave
equipment can be used. Corrosion rates are determined by weight loss of the metal coupons.
After the testing, the coupon will be cleaned and reweighed. The difference in coupon weight is
used to calculate the corrosion rate.

NACE corrosion test cell equipment -The NACE cell is a single cell pressure vessel
designed to test corrosion inhibitors at temperatures up to 300oF (149oC) and pressure from
ambient to 1000psi. The testing is done in duplicates to ensure a greater accuracy.

NACE Corrosion Test Cell (300oF – 1000psi)

Nalco Company
P.O. Box 87 Sugar Land TX ● 77487-0087 ● 1 281 263 7000
SUBSIDIARIES AND AFFILIATES IN PRINCIPAL LOCATIONS AROUND THE WORLD
©2006 Nalco Company

3
Corrosion test autoclave equipment - The high-pressure autoclave equipment was
used for conditions up to 400oF (204oC) temperature and 5000psi pressure. The equipment is
maintained and used per manufacturer’s recommendation.

High Pressure Corrosion Test Autoclave (up to 400oF – 5000psi)

Disclaimer: The contents of this document are, to the best of our knowledge, accurate at the date of publication. We shall not be liable for any loss or damage
whatsoever resulting from reliance on its contents. All warranties as to fitness for purpose or otherwise (howsoever made or implied) in respect of this publication
are excluded.