You are on page 1of 15

T D S Description T D S Description

Project name - Residence D.4.2 - Filling to excavation


Construction Stage 1 for foundation. Quarry dust
Drg. No - 01 filling
Taker - Navodya (D20.9.2.3)
Date - 20/03/2018
D.4.3 - Filling to excavation
Taking off List for foundation

D - Groundwork
D.1 - Site Preperation (D20.9.1.1)
(D20.1.3)
D.4.4 - Filling to make up
D.2 - Excavations levels
D.2.1 - Topsoil for (D20.10.1.3)
preservation
(D20.2.1.1) E - Insitu concrete
E.1 - In-situ concrete
D.2.2 - To reduce levels,
maximum depth not E.1.1- Insitu concrete for
exceeding 0.25 m foundation
(D20.2.2.1) (E10.4.1)
.
D.2.3 - Excavating pits for E.1.2 - In-situ concrete for
column and staircase beds for column base
foundations (E10.4.1)
(D20.2.4.1)

D.2.4 - Excavating trenches, E.1.3 - In-situ concerete beds


width exceeding 0.3 m for staircase foundation base

(D20.6.1) (E10.4.1)
D.3 - Earthwork support

D.3.1 - Earthwork supports E.1.3 - Insitu concrete for


and thereafter in 2.00 m, staircase shaft up to finished
Distance between opposing floor level
faces not exceeding 2.00 m
(D20.7.3.1) (E10.3)

D.4 - Filling to excavation

D.4.1 - Filling to excavation,


average thickness exceeding
0.25 , quarry dust filling
(D20.9.2.3) E.2- Formwork for
substructure
D.4.2 - Filling to excavation E.2.1 - Formwork for side
for foundation. Quarry dust works of Column base

(D20.9.2.3) (E20.1.1.1)
T D S Description T D S Description

E.2.2 - Formwork for Column F - Masonary


shaft upto DPC
(E20.15.2.1) F.1 - Random rubble
masonary for 112.5 wall
E.2.3 - Formwork for 112.5 foundation
mm brick wall foundation (F20.1.1.1)
(E20.1.1)

E.2.4 - Formwork for 225 F.2 - Random rubble


brick wall foundation masonary for 112.5 wall
(E20.1.1) foundation
(F20.1.1.1)
E.2.5 - Formworks for
staircase foundation base J - Waterproofing
(E20.1.1)
J.1 - Damp Proof Cource
E.2.6 - Formwork for
staircase shaft up to DPC (J40.1.1)
(E20.1.1)

E.3 -Reinforcement for J.1 - Damp Proof Membrane


substructure (J40.1.1)
E.3.1 - Reinforcement for
column base
(E30.1.1.1)

E.3.2 - Reinforcement for


column shaft upto DPC

(E30.1.1.1)

E.3.3- Reinforcement for


staircase base
(E30.1.1.1)

E.3.3- Reinforcement for


staircase shaft up to DPC
(E30.1.1.1)

E.3.4 - Reinforcement for


112.5 mm wall foundation
(E30.1.1.1)

E.3.5 - Reinforcement for 225


mm wall foundation
(E30.1.1.1)

E.3.5 - Reinforcement for


Column shaft up to DPC
(E30.1.1.1)
T D S Description T D S Description

SUPERTRUCTURE

E – In-situ Concret

E.4 - Concrete works in


superstructure

E.4.1 - RCC concrete for


beams
(E10.9.1.1)

E.4.2 -RCC Concrete for


column from DPC to first
floor level
(E10.11.1.1)

E.4.3 - RCC conrete for slabs


in first floor
(E10.5.2)

E.5 - Formwork for


Subtructure

E.5.1 - Formwork for columns


from DPC to FFL

(E20.1.1)

E.5.2 - Formwork for beams


(E20.2.1.2)

E.5.3 - Formwork for soffits


of slabs
(E.20.8.1.1)
T D S Description T D S Description
T D S Description T D S Description
Add Walls
1/0.5/225 112.5
36917.5

Mean Girth Total Mean Girth


49,740.00
366917.5
External Wall Mean Girth 86432.5

4800
2/3225 6850 SUBSTRUCTURE
2/600 1200
2/3225 6850 D – Groundwork
2/750 1500 D.1. – Site Preparation
1056
1550 21.9 D.1.1 -Clearing site
384 7.59 vegetation for site
33840 166.2 preperation
(D20.1.3)
2/7590 15900
49740
7950
Ddt. Walls
2/2/0.5/225 450
49290 18890

Internal Wall Mean Girth


2425
600
6450 ROAD
2880
3168
2000
17523 18900
Add Spread
3/2850 8550 1/3000 3000
3/450 1350 21900
3/1550 3100
4650
1632 7590
36805
T D S Description T D S Description
1.2 Footing 2
1.2
D.2 – Excavating 2.1 3.02
5.34 2100
21.9 D.2.1 - Clearing topsoil for
7.59 preservation to an average
166.2 depth of 150 mm and
preserved on site for re- 1200
use in soil heaps and an
average 20 m away from
D.2.4 – Excavating
the site. 16.38 trenches for typical 112.5
(D20.2.1.1) 0.45
mm brick wall foundation,
1.05
width exceeding 0.30 m,
a.b.d in D.1 7.74
maximum depth not
exceeding 1.00 m and
D.2.2. – Excavating to disposal of excavated
19.2
reduce levels to maximum materials off site
7.95
depth not exceeding 0.25
152.6 (D20.2.6.2)
m and surplus materials to
2425
be removed 5 km away
600
from the site.
3225
(D20.2.2.1) 2000
2500
3125
D.2.3 - Excavating pits and 13875
for column base,
maximum depth is not 775
exceeding 2.00 m Add Wall
(D20.2.4.3) 2/2/0.5/112.5 225
16375
1.05 Footing 1
1/
1.05 0.5/ 0.45 Ddt. T junctions
2.1 0.45
2.32 2100 1.05 0.11
7.63

3/
0.5/ 0.45 Ddt. T junctions
1050 0.6
1.05 0.21
7.42
2000
2500
3125
13875
T D S Description T D S Description
775 Total Length
1500 49740
13000
Add Wall 62740
2/2/0.5/112.5 225
16375
D.4 - Filling to excavation
1/
0.5/ 0.45 Ddt. T junctions
0.45
D.4.1 - Filling to Excavation
1.05 0.11
column pits using Quarry
7.63
dust, average thickness
3/
exceeding 0.25 m
0.5/ 0.45 Ddt. T junctions
0.6 (D20.9.2.3)
1.05 0.21
7.42 11/ 1.05 Footing 1
1.05
6/
0.5/ 0.6 Ddt. T junctions 1.5
0.6 18.19
1.05 1.13
6.29 6/ 1.2 Footing 2
1.2
1.5 12.96
62.74 D.2.5 - Excavating trenches 31.15
0.6 for typical 225 mm brick
1.2 wall foundation, width
45.17 exceeding 0.30 m, D.4.2 - Filling to excavation,
maximum depth not avarage thickness not
exceeding 2.00 m and exceeding 0.25 m generally
Disposal of excavated selected material arising out
materials off site of excation other than
topsoils or rock
(D20.2.6.2)
(D20.9.1.1)

External wall Mean girth


49740 0.90 Staircase base
0.23
Internal walls 0.60 0.12
3/2850 8550 51.46
3/450 1350
3/1550 3100
13000
T D S Description T D S Description

2/ 16.38
0.50 D.4.2.1 - 112.5 mm brick wall
0.08 300 mm
1.32

500mm

2/ 62.74
0.5 D.4.2.1 - 225 mm brick wall
0.08 50.02
51.34 450 mm

500mm
T D S Description T D S Description
D.4.8 - Filling to make up 0.23 2.25 Ddt.
levels for average 17.25 2/0.5/300 300
thickness not exceeding 2125
0.25 selected materials to
be hardbroken compacted 2850
with an 200 mm tonne 450
roller in 150 mm layers. 1550
4850

2.88 Grid (1a-3)/(C-D)


1.25 2500
(D20.10.1.3) 0.23 0.83 384
2.8 Grid (1a-3)/(A-C) 2.47 2884
2.55 1/3100 3100
0.23 Ddt.
1.64 Ddt. 1/0.5/300 150
2/0.5/300 300 2734
2800
1550
2850 Ddt.
Ddt. 2/0.5/300 300
2/0.5/300 300 1250
2550

3.53 Grid (6-4)/(A-B) 9.05 Grid (2-5)/(F-D)


2.25 3225 3.03 3325
0.23 1.83 600 0.23 6.31 2925
13.62 3825 8.78 3100
Ddt. 9350
2/0.5/300 300 Ddt.
3525 2/0.5/300 300
9050
2250
1255
3.53 Grid (6-4)/(D-B) 2075
1.7 a.b.d 3330
0.23 1.38 3525 Ddt.
15 2/0.5/300 300
450 3030
1550
2000
Ddt. 2.7 Grid (3-4)/(A-D)
2/0.5/300 300 4.55 2700
1700 0.23 3.01
11.79 2850
450
1550
4850
T D S Description T D S Description

Ddt. T junctions
2/0.5/300 300 62.74 E.1.1.2 - Grade 25
4550 0.6 reinforcement concrete mix
1.2 45.17 with 1:1 1/2: 3 with minimum
cement content of 300 Kg/m
D.5 - Earthwork supports for 18 mm sized aggregates for
query dust pits 225 mm brick wall
foundation
11/
4/ 1.05 Footing 1
1.5 69.3
(E10.1.)
6/
4/ 1.2 Footing 1
1.5 43.2
112.5 E.1.2.1 - 50 mm thick screed
concrete of grade 15 1:3:6
mix 25 mm maximum sized
aggregates of concrete for
beds for Screed concrete
E.1 - In-situ concrete (E10.4.1)
11/ 1.05 Footing 1
E.1.1- Insitu concrete for 1.05
foundation 0.05 6.06
(E10.4.1)
6/ 1.2 Footing 2
1.2
16.38 0.05 0.43
0.45 E.1.1.1 - Grade 25 6.49
0.1 0.74 Reinforcemnt concrete
mix with 1:1 1/2: 3 with
minimum cement content
of 300 Kg/m 18 mm sized
aggregates for 112.5 mm
brick wall foundation
(E10.1.)
1/
0.5/ 0.45 Ddt. T junctions
0.45
0.1 0.01
0.73

3/
0.5/ 0.45 Ddt. T junctions
0.6
0.1 0.04
0.69
6/
0.5/ 0.6 Ddt. T junctions
0.6
0.1 0.12
0.57
T D S Description T D S Description

E.1.2.1 - Grade 25 1:1 1/2 :3


mix 18 mm maximum sized
aggregates of concrete for
column base
(E10.3.1) E.1.3 - Insitu concrete for
11/ 1.05 Footing 1 staircase foundation base
1.05 D = (D1 +D2)÷2
0.19 2.3 =(175+200)÷2 (E10.4.1)
=187.5

Footing 2
D = (D1 +D2)÷2
6/ 1.2 =(225+250)÷2
1.2 =237.5
0.24 2.07
4.37

E.1.3 - Grade 25
Reinforcemnt concrete
mix with 1:1 1/2: 3 wit 18
mm sized aggregates for
column shaft upto DPC
(E10.3.1)
11/ 0.23 Footing 1
0.23
1.2 0.7

6/ 0.23 Footing 2
0.23
1.2 0.38
1.08
T D S Description T D S Description
E.2- Formwork for E.2.6 - Formwork for
substructure staircase shaft up to DPC
(E20.1.1)

E.2.1 - Formwork for side


works of Column base

(E20.1.1.1)

11/4/ 1.05 Footing 1


0.19 8.78 a.b.d

7/4/ 1.2 Footing 2


0.24 8.06 a.b.d
16.84

E.2.2 - Formwork for


Column shaft upto DPC
(E20.15.2.1)

11/4/ 0.23 Footing 1


1.2 12.14

7/4/ 0.23 Footing 2


1.2 7.73
19.87

E.2.3 -Formwork for 112.5


mm brick wall foundation

2/ 16.38
0.1 3.28

(E20.1.1)

2/ 62.74 E.2.4 - Formwork for 225


0.1 12.55 mm brick wall foundation
15.83
(E20.1.1)
T D S Description T D S Description
E.3 -Reinforcement for
substructure R6 @ 150 mm

E.3.1 - Reinforcement for


column base T10@ 125
11/
11/ mm main bars 11/ 1.02 123.4
9/ 225
2 0.98 194 1/1050 1050

Ddt. Cover 225


2/37.5 75
975

No: of bars Length of the strirrups


(1050 ÷ 125)+1 = 9.4 2(a+b)+20d
=9 =2(225+225) + 20 × 6
=1020
E.3.2.1 - Reinforcement for
column shaft upto DPC 4T12 No: of Stirrups
main bars with sirrups R6
@150 mm (1555÷150)+1 = 11.36
=11

R6 @ 150 mm
Length of the bar
1/450 450
1200 Ddt. Covers
` 450 2/37.5 75
375

No: of Bars

11/
4/ 1.56 68.64

Length of the bar


1/600 600
1/300 300
1/225 225
1/75 75
1/450 450
1650
Ddt. Covers
2/37.5 75
1575
Ddt. Bar dia
2/10 20
1555
T D S Description T D S Description
Ddt. Covers
E.3.2.2 - Reinforcement for 2/37.5 75
column shaft upto DPC 4T16 375
main bars with sirrups R6
@150 mm

R6 @ 150 mm
Length of the bar
1/450 450
1200 Ddt. Covers
2/37.5 75
375

E.3.3 - Reinforcement for


225 mm brick wall
foundation
450
E.3.5 - Reinforcement for
225 mm brick wall
11/
4/ 1.56 68.64 foundation
Length of the bar
a.b.d 10/ 0.53 5.3 4T10
Length of the bar
1/600 600
Ddt. Covers
2/37.5 75
525

0.53 R6 @ 150 mm
11/
11/ 1.02 123.4 R6 @ 150 mm Length of the bar
1/600 450
Length of the strirrups Ddt. Covers
a.b.d 2/37.5 75
1020 525

No: of stirrups
a.b.d
11

E.3.4 - Reinforcement for


112.5 mm brick wall
foundation

3/ 3.75 11.25 3T10


Length of the bar
1/450 450
T D S Description T D S Description

11 9
//
2/ 0.98 (E30.1.1.1)