You are on page 1of 2

RENR7299-09

Harness And Wire Electrical Schematic Symbols


January 2014 Symbols

Pressure Temperature Level Flow Circuit Breaker


Symbol Symbol Symbol Symbol Symbol

Symbols and Definitions


Fuse: A component in an electrical circuit that will open the circuit if too much current flows
through it.

Switch (Normally Open): A switch that will close at a specified point (temp, press, etc.). The
circle indicates that the component has screw terminals and a wire can be disconnected from it.

Switch (Normally Closed): A switch that will open at a specified point (temp, press, etc.).
No circle indicates that the wire cannot be disconnected from the component.

Ground (Wired): This indicates that the component is connected to a grounded wire. The
grounded wire is fastened to the machine.

Ground (Case): This indicates that the component does not have a wire connected to ground.

Schematic It is grounded by being fastened to the machine.

Reed Switch: A switch whose contacts are controlled by a magnet. A magnet closes the
contacts of a normally open reed switch; it opens the contacts of a normally closed reed switch.

307D, 311D, 311F, 312D, 312D2, 313D, 313D2, T


Sender: A component that is used with a temperature or pressure gauge. The sender
measures the temperature or pressure. Its resistance changes to give an indication to
the gauge of the temperature or pressure.

315D, 318D, 318D2, 319D, 320D, 320D2, 323D Relay (Magnetic Switch): A relay is an electrical component that is activated by electricity.
It has a coil that makes an electromagnet when current flows through it. The
and 323D2 Excavators and M313D, M315D, electromagnet can open or close the switch part of the relay.

M316D, M318D and M322D Wheeled Excavators Solenoid: A solenoid is an electrical component that is activated by electricity. It has a
coil that makes an electromagnet when current flows through it. The electromagnet
can open or close a valve or move a piece of metal that can do work.

Air Conditioning Electrical System Magnetic Latch Solenoid: A magnetic latch solenoid is an electrical component that is
activated by electricity and held latched by a permanent magnet. It has two coils (latch and unlatch)
that make electromagnet when current flows through them. It also has an internal switch that places
the latch coil circuit open at the time the coil latches.

Harness and Wire Symbols


Wire, Cable, or Harness Harness Identification Letter(s):
Assembly Identification: Includes (A, B, C, ..., AA, AB, AC, ...)
Harness Identification Letters and
Harness Connector Serialization Code:
Harness Connector Serialization
The "C" stands for "Connector" and the
Codes (see sample).
number indicates which connector in the
AG-C4 L-C12 harness (C1, C2, C3, ...).
L-C12
111-7898 3E-5179 3E-5179
Part Number: for Connector Plug 1
Part Number: for Connector Receptacle
2
Plug Receptacle
Pin or Socket Number
5A
1 Deutsch connector: Typical representation
Component
of a Deutsch connector. The plug contains all Fuse (5 Amps) 9X-1123 Part Number
2 sockets and the receptacle contains all pins.
325-AG135 PK-14
1 Sure-Seal connector: Typical representation Harness identification code:
of a Sure-Seal connector. The plug and receptacle This example indicates wire group 325, Wire Gauge
2 contain both pins and sockets. wire 135 in harness "AG". Wire Color

© 2014 Caterpillar CAT, CATERPILLAR, their respective logos, “Caterpillar Yellow”, and the POWER EDGE trade
All Rights Reserved dress as well as corporate and product identity used herein, are trademarks of Caterpillar and
SAFETY.CAT.COM may not be used without permission.

RENR7299-09
12 Page,B/W
7 6 5 4 3 2 1

F F
1
Control Panel
BU/OR-20 Type 2

1
BR/WH-20 PU/RD-20
BU/BK-20 PK/BK-20
BR/BK-20 CONN AA
S-BU-20
PK-20
PU/GN-20

1
2
3
4
5
6
7
8
9
10

12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
11
BK/RD-20
L-GN/RD-20 WH/RD-20 Control Panel
PU/YL-20 Type 1 CONN A

L-GRN/RD-20

L-GRN/YL-20
BK/GN-20

BLU/ORN-20

ORN/BLU-20
PU/GRN-20

BR/ORN-20
BK/GRN-20

PK/GRN-20
GY/BLU-20
BLU/BK-20
WH/RD-20

BR/WH-20

WH/YL-20
PU/RD-20

BK/RD-20
BR/BK-20

GY/YL-20

PK/BK-20
S-BLU-20
PU/YL-20
BK/YL-20
9 10 11 12 13 14 15 16 23 24 25 26 27 28

PK-18

BK-20
1 2 3 4 5 6 7 8 17 18 19 20 21 22
CONN AA

1
2
3
4
5
6
7
8
9
10

12
13
14
15
16

17
18
19
20
21
22
23
24
25
26
27
28
11
BK-20
L-GN/YL-20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40
GY/YL-20
WH/YL-20 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
PK/GN-20
BR/OR-20 DETAIL OF CONN AA CONN A
BK/YL-20 Type 1

L-GN/RD-20

L-GN/YL-20
WH/RD-20
BR/WH-20
DETAIL OF CONN AA

PK/GN-20

OR/BU-20

BU/OR-20

PU/GN-20

BR/OR-20
WH/YL-20
BK/GN-20

GY/BU-20

PU/RD-20
GY/BU-20

BK/RD-20

BR/BK-20
BU/BK-20

PK/BK-20
GY/YL-20
PU/YL-20

BK/YL-20

S-BU-20
OR/BU-20 Type 2 1 2 1 2 1 2

PK-20

BK-20
DETAIL OF CONN A
Type 1 L-GRN/RD-20 BK/GRN-20
BR/BK-20
BLU/BK-20
ORN/BLU-20
PK/GRN-20
DETAIL OF CONN JJ DETAIL OF CONN HH DETAIL OF CONN GG
PU/GRN-20 GY/BLU-20
WH/RD-20 PU/YL-20
PU/RD-20 BK/YL-20
BLU/ORN-20 GY/YL-20

GY/BU-20 GY/YL-20 GY/BU-20 BK/YL-20 GY/YL-20 PK/GN-20


PU/YL-20 L-GN/RD-20 GY/YL-20
BK/YL-20 OR/BU-20 BK/GN-20
GY/YL-20 PK/GN-20 PK-18 BR/BK-20
BR/WH-20 BK-20 BK/RD-20 BU/BK-20
BR/WH-20 PK-18 BK-20
BR/ORN-20 S-BLU-20 BK/RD-20
L-GRN/YL-20 PK/BK-20

BK-20
WH/YL-20
DETAIL OF CONN A
DETAIL OF CONN J DETAIL OF CONN H DETAIL OF CONN G
BK/RD-20 BU/BK-20 BR/WH-20

E PK-20 BR/BK-20 GY/YL-20 PK/GN-20 Type 2

L-GN/RD-20

L-GN/YL-20
WH/RD-20
BR/WH-20
BK/GN-20

PK/GN-20

OR/BU-20

BU/OR-20

PU/GN-20

BR/OR-20
WH/YL-20
BK/GN-20

GY/BU-20

PU/RD-20
BK/RD-20

BR/BK-20
BU/BK-20

PK/BK-20
GY/YL-20
PU/YL-20

BK/YL-20
BK/YL-20

S-BU-20
PU/YL-20 L-GN/RD-20

PK-18

BK-20
GY/BU-20 OR/BU-20 CONN CC
CONN BB

1
2
3
4
5
6
7
8
9

1
2
3
4
5
6
7
8
9
10

12
13
14

10
11
DETAIL OF CONN BB DETAIL OF CONN B

L-GN/RD-20

L-GN/YL-20
WH/RD-20
BR/WH-20

PK/GN-20

OR/BU-20

BU/OR-20

PU/GN-20

BR/OR-20
WH/YL-20
BK/GN-20

GY/BU-20

PU/RD-20
BK/RD-20

BR/BK-20
BU/BK-20

PK/BK-20
GY/YL-20
PU/YL-20

BK/YL-20

S-BU-20
CONN C

PK-20

BK-20
CONN B
CONN CC
PU/RD-20 PK/BK-20 CONN BB

WH/YL-20 BU/OR-20
L-GN/YL-20

1
2
3
4
5
6
7
8
9

1
2
3
4
5
6
7
8
9
10

12
13
14

10
11
S-BU-20 BR/OR-20 S-BU-20
1 2 3 4 5 6 7

CONN B CONN C L-GN/RD-20

3
WH/RD-20

4
L-GN/RD-20

L-GN/YL-20
PU/GN-20

WH/RD-20
BR/WH-20

OR/BU-20

BU/OR-20

PU/GN-20

WH/YL-20
BK/GN-20

PK/GN-20

GY/BU-20

PU/RD-20
GY/YL-20

BK/RD-20

BR/BK-20
BU/BK-20

PK/BK-20
GY/YL-20
PU/YL-20

BK/YL-20

S-BU-20
WH/RD-20 PU/GN-20 WH/RD-20 PU/YL-20
PU/GN-20

PK-18

BK-20
CONN JJ CONN HH CONN GG
BU/OR-20 WH/YL-20 L-GN/YL-20
PK/BK-20
PU/RD-20 DETAIL OF CONN K DETAIL OF CONN KK

1
2

1
2

1
2
DETAIL OF CONN CC DETAIL OF CONN C
CONN J CONN H CONN G

GY/YL-20 BK/RD-20

GY/BU-20

PK/GN-20
GY/YL-20

GY/YL-20

GY/YL-20
BK/YL-20
15
BK-20
OR/BU-20

OR/BU-20
BK-20 GY/YL-20
BK/RD-20
BR/WH-20

DETAIL OF CONN DD DETAIL OF CONN D


5
GY/YL-20

1 2
MOTOR
OR/BU-20
5A

WH/RD-20 7

D DETAIL OF CONN EE DETAIL OF CONN E


PU/GN-20
PU/YL-20
6
5 D
4
GY/YL-20 3

14 L-GN/RD-20
2
1
OR/BK-20

BK-20 BK/RD-20 1 2 3 4 5 6 7
CONN E CONN D CONN K CONN KK
CONN EE CONN DD
S-BU-20 OR/BK-20
PK/BK-20
2 OR/BU-20 OR/BU-20 1 OR/BU-20
1 GY/YL-20 GY/YL-20 2 GY/YL-20
DETAIL OF CONN F 3 DETAIL OF CONN L DETAIL OF CONN LL
4
BK/RD-20 5 BK/RD-20
BK-20 6 BK-20

13 L-GN/RD-20 BU/OR-20

1 2
1 2 3 4 5 6 7
2 BK/RD-20
1 BK-20 GY/YL-20 PU/RD-20
BK/GN-20
DETAIL OF CONN FF
CONN FF CONN F
6
12
DETAIL OF CONN M DETAIL OF CONN MM

RD-14 RD/GN-16
PK-18
OR/BK-20

OR/BK-18 BK-14
BK-14 BR/BK-20
MOTOR
3 4
1 2
OR/BK-20 OR/BK-20 7
6 BK/BU-14 BU/BK-20
5
4
DETAIL OF CONN S PK/BK-20 3
DETAIL OF CONN N DETAIL OF CONN NN
OR/BK-18

2
RD-18
BK-18

S-BU-20 1

C
CONN T

C 1 2 CONN L CONN LL

LIGHT

Components List
Item
1 OR/BK-18

7
2
3 RD-14
4
5
RD/GN-16
PK-18
No. Description Part#
1 Control Panel Assembly (1)
6 BK-14
7
MOTOR
8
9
10 PU/RD-20 7
2 Water Temperature Sensor 245-7831
11 BU/OR-20 6
3 Frost Sensor 245-7835
10A

15A

12 BK/GN-20 5

4 Recirculation Temperature Sensor 245-7815


4
L-GN/RD-20 3
2
CONN S
GY/YL-20 1 5 Actuator 245-7817
CONN M CONN MM 6 Actuator 245-7813
7 Actuator 245-7817
RENR7299-09

POS NEG
8 Blower Control 245-7832
9 Blower Motor 245-7839
L-GN/YL-20
RD/GN-16
OR/BK-20

WH/YL-20

PK/BU-14
BK/BU-14

BU/BK-20
BR/BK-20

BK/BU-14
OR/BK-20

PK/BU-14
0R/BK-20

10 Blower Main Relay 196-1666


BK-14
RD-14

CONN R
CONN N
CONN U CONN P
11 Clutch Solenoid Relay 196-1666
12 Refrigerant Compressor (1)
1

1
1

4
2

3
1
4

3
2

3
2

CONN RR CONN PP
CONN UU CONN NN
12 Page, B/W

13 Pressure Switch 130-0270


14 Ambient Temperature Sensor 235-8874 B
MOTOR

B
11 10 9 8 15 Air Conditioner Group (1)
(1) Refer to the parts manual for your machine for the current part numbers

OR/BK-20 RD/GN-16 OR/BK-20 PK/BU-14


BK/BU-14
3 4
3 4 2 1
1 2
1 2
RD-18 BK-18
PK/BU-14
L-GN/YL-20 OR/BK-20
WH/YL-20 RD-14

DETAIL OF CONN T DETAIL OF CONN UU


DETAIL OF CONN P DETAIL OF CONN PP
DETAIL OF CONN U DETAIL OF CONN R DETAIL OF CONN RR

A A

This Schematic is for the Air Conditioning System - 307D, 311D, 311F, 312D, 312D2,
313D, 313D2, 315D, 318D, 318D2, 319D, 320D, 320D2, 323D and 323D2 Excavators
and M313D, M315D, M316D, M318D and M322D Wheeled Excavators
PART #: 235-8967, 372-9415, 420-7570

7 6 5 4 3 2 1

You might also like