Series PV

Hydraulics Variable Volume


Piston Pumps

Catalog 2600-600-2/USA
! WARNING
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED
HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.

This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide
product and/or system options for further investigation by users having technical expertise. It is important that you analyze
all aspects of your application including consequences of any failure, and review the information concerning the product
or system in the current product catalog. Due to the variety of operating conditions and applications for these products
or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products
and systems and assuring that all performance, safety and warning requirements of the application are met.

The products described herein, including without limitation, product features, specifications, designs, availability and
pricing, are subject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice.

Offer of Sale
The items described in this document are hereby offered for sale by Parker Hannifin Corporation, its subsidiaries or its
authorized distributors. This offer and its acceptance are governed by the provisions stated on the separate page of this
document entitled “Offer of Sale”.

© Copyright 1997, Parker Hannifin Corporation. All Rights Reserved

Parker Hannifin Corporation


Hydraulic Pump/Motor Division
Hydraulics Otsego, MI 49078
Variable Volume Piston Pumps
Index Series PV

Introduction - General PV Series ........................................................................................................... 1-3

PV 016/020/023 Series ......................................................................................................................... 4-9


Performance Information .................................................................................................................... 4
Ordering Information .......................................................................................................................... 5
Performance Curves .......................................................................................................................... 6
Installation Dimensions ................................................................................................................... 7-9

PV 032/040/046 Series ..................................................................................................................... 10-15


Performance Information .................................................................................................................. 10
Ordering Information ........................................................................................................................ 11
Performance Curves ........................................................................................................................ 12
Installation Dimensions ............................................................................................................... 13-15

PV 063/080/092 Series ..................................................................................................................... 16-21


Performance Information .................................................................................................................. 16
Ordering Information ........................................................................................................................ 17
Performance Curves ........................................................................................................................ 18
Installation Dimensions ............................................................................................................... 19-21

PV 130/180 Series ............................................................................................................................ 22-25


Performance Information .................................................................................................................. 22
Ordering Information ........................................................................................................................ 23
Performance Curves ........................................................................................................................ 24
Installation Dimensions .................................................................................................................... 25

PV250 Series .................................................................................................................................... 26-29


Performance Information .................................................................................................................. 26
Ordering Information ........................................................................................................................ 27
Performance Curves ........................................................................................................................ 28
Installation Dimensions .................................................................................................................... 29

Control Options - General PV Series ................................................................................................ 30-33

Offer of Sale ........................................................................................................................................... 34

Parker Hannifin Corporation


Hydraulic Pump/Motor Division
Hydraulics Otsego, MI 49078
Parker Hannifin Corporation
Hydraulic Pump/Motor Division
Hydraulics Otsego, MI 49078
Variable Volume Piston Pumps
Introduction Series PV
General Description
All control of the pump outlet flow is achieved by the forced away from the port plate drawing in fluid, and
proper positioning of the swash plate. Control is in the other half of the revolution, the pumping pistons
accomplished when the bore area forces of the servo are forced toward the port plate driving out fluid.
piston acting on one end of the swash plate working The volume of fluid the pump will displace in one
against the combined effects of the bias spring, and revolution of the shaft is dependent upon the area of
the rod area forces of the servo piston acting on the the pumping piston, the number of pumping pistons
other end. and the angle of the swash plate. The swash plate is
As the shaft in the figure below is rotated by a prime shown at maximum angle and will produce maximum
mover, it in turn rotates the cylinder barrel. As the displacement. As the swash plate is moved toward a
cylinder barrel rotates, it drives the pumping pistons vertical position (perpendicular to shaft centerline),
in a circular path with the piston slippers supported the displacement will decrease until it reaches the
hydrostatically against the angled swash plate. In vertical position and displacement is zero.
one-half of the revolution, the pumping pistons are

BORE ROD SERVO CHAIN SWASH CASE DRAIN


AREA AREA PISTON LINK PLATE PORT
BIAS
SPRING

ROLLER
BEARING

MAXIMUM
VOLUME
ADJUSTMENT

SHAFT
NEEDLE
BEARING

PORT CYLINDER PUMPING PISTON


PLATE BARREL PISTON SLIPPER

Parker Hannifin Corporation


1 Hydraulic Pump/Motor Division
Hydraulics Otsego, MI 49078
Variable Volume Piston Pumps
Introduction Series PV

Quick Reference Data Chart


Pump Delivery *Approx. Noise Levels dB(A) Horsepower At Max.
Displacement
Pump @ 100 PSI (7 bar) @ Full Flow and 1500 RPM 1800 RPM, Max. Operating
Model cc/rev in GPM (LPM) Displacement & Speed
(In3/rev) 1000 PSI 3000 PSI 5000 PSI
1200 RPM 1800 RPM (69 bar) (207 bar) (345 bar) 5000 PSI (PRM)

PV016 16 (.98) 5.1 (19.2) 7.6 (28.8) 56 61 68 22.5 2750


PV020 20 (1.22) 6.3 (24.0) 9.5 (36.0) 56 61 68 33.8 2750
PV023 23 (1.40) 7.3 (27.6) 10.9 (41.4) 56 61 68 38.6 2750
PV032 32 (1.95) 10.1 (38.4) 15.2 (57.6) 59 63 69 48.3 2400
PV040 40 (2.44) 12.7 (48.0) 19.0 (72.0) 59 63 69 62.8 2400
PV046 46 (2.81) 14.6 (55.2) 21.9 (82.8) 59 63 69 72.4 2400
PV063 63 (3.84) 20.0 (75.6) 30.0 (113.4) 63 68 73 99.8 2100
PV080 80 (4.88) 25.4 (96.0) 38.0 (144.0) 63 68 73 122.3 2000
PV092 92 (5.61) 29.2 (110.4) 43.8 (165.6) 63 68 73 144.8 1900
PV130 130 (7.93) 41.2 (156.0) 61.8 (234.0) 77 82 83 205.0 1800
PV180 180 (10.98) 57.1 (216.0) 85.6 (324.0) 79 84 86 284.0 1800
PV250 250 (15.26) 79.3 (300.0) 97.5 (369.0) 81 86 88 320.7 1800
* The noise level values are based on anechoic room measurements at a distance of 1 meter in accordance with DIN 45645.

Parker Hannifin Corporation


2 Hydraulic Pump/Motor Division
Hydraulics Otsego, MI 49078
Variable Volume Piston Pumps
Installation Information Series PV

Use of a Relief Valve


The use of a relief valve, while not mandatory is
recommended in the main circuit to suppress hydraulic
shock loads and adds additional system protection.

Fluid Recommendations
Premium quality hydraulic oil with a viscosity range
between 150-250 SSU (30-50 cst.) at 100°F (38°C).
Normal operating viscosity range between 80-1000
SSU (17-180 cst.). Maximum start-up viscosity is 4000
SSU (1000 cst.).

NOTE: Consult Parker when exceeding 160°F (71°C)


operation. Oil should have maximum anti-wear
properties, rust and oxidation treatment.

Shaft Rotation and Line Up


Filtration
Pump and motor shaft alignment must be within
For maximum pump and system component life, the .010 TIR maximum, using a standard floating coupling.
system should be protected from contamination at Please follow coupling manufacturer’s recommended
a level not to exceed 125 particles greater than 10 installation instructions to prevent end thrust on pump
microns per milliliter of fluid. (SAE Class 4/ISO 16/13.) shaft. Turn pump to assure freedom of rotation. Pump
Due to the nature of variable displacement pumps, and motor must be on a rigid base.
variations in pump inlet conditions, fluid acceleration
losses, system aeration, and duty cycle we do not
The coupling should be sized to absorb the peak
recommend suction line filters. We do recommend
the use a properly sized, in-tank, suction strainer. horsepower developed.
Contact your Parker representative for assistance.
Installation and Mounting
Start-Up When mounting a PV Series Pump, the “case drain”
must be on top of the pump. The “case drain” should
On initial start-up, the pump case must be filled with
be a separate line unrestricted to the reservoir and
fluid. Pressure adjustments should be reduced and
extend below the oil level as far from the inlet line
the circuit should be open to permit priming.
as possible. The “case drain” line must not exceed
10 PSI (.69 bar) back pressure.
Special Installations
Consult your Parker representative for any application The “case drain” line should be as large in diameter
requiring the following: as possible and as short in length as possible.
Suggested maximum line length is 10 ft.
Pressure above rated, drive speed above maximum,
indirect drive, fluid other than petroleum oil, fluid Check that the driving motor rotates in the same
temperature above 160°F (71°C). direction as indicated by the rotation arrow on the
pump.

Parker Hannifin Corporation


3 Hydraulic Pump/Motor Division
Hydraulics Otsego, MI 49078
Variable Volume Piston Pumps
Technical Information Series PV 016/020/023

Performance Information
Series PV, Pressure Compensated, Variable Volume,
Piston Pumps

Features
• High Strength Cast-Iron Housing for high reliability
and quiet operation
• Modular Controls for field convertability
• Large Control Piston for fast response
De-stroking in 45 mS
On-stroking in 70 mS
• Thru-Shaft Option with 100% thru torque capability
• 9 Piston Design to minimize ripple
• Multiple Pressure Control with valves mounted
directly on pump
Specifications
Controls Pressure Ratings: 5000 PSI (350 bar) Continuous
• Pressure Compensation 6000 PSI (420 bar) Peak
• Load Sensing
• Remote Pressure Compensation Speed Ratings: 600 to 2750 RPM
• Adjustable Maximum Volume Stop
• Electrohydraulic Pressure Inlet Condition: 230 PSI (16 bar)
• Dual and Tri-Pressure Maximum Inlet Charge
• Low Pressure Standby 5 In. Hg. Max. Vacuum at
1800 RPM
• Horsepower Limiting

Schematic Symbol Case Drain 30 PSI (2 bar) Maximum


Conditions:
(Basic Pump)

Operating -40°F to 160°F


Temp. Range: (-40°C to 70°C)

Installation Data Housing Material: Cast Iron


See Installation Information on page 3 of this catalog
for specific recommendations pertaining to system Filtration: Maintain SAE Class 4 (ISO 16/13)
cleanliness, fluids, start-up, inlet conditions, shaft
alignment, drain line restrictions and other important Mounting: SAE “B” 2 and 4-Bolt Flange
factors relative to the proper installation and use of
these products.

Quick Reference Data Chart


Pump Delivery *Approx. Noise Levels dB(A) Horsepower At Max.
Pump Displacement @ 100 PSI (7 bar) @ Full Flow and 1500 RPM 1800 RPM, Max. Operating
cc/rev
Model in GPM (LPM) 1000 PSI 3000 PSI 5000 PSI Displacement & Speed
(in3/rev) 5000 PSI (PRM)
1200 RPM 1800 RPM (69 bar) (207 bar) (345 bar)
PV016 16 (.98) 5.1 (19.2) 7.6 (28.8) 56 61 68 22.5 2750
PV020 20 (1.22) 6.3 (24.0) 9.5 (36.0) 56 61 68 33.8 2750
PV023 23 (1.40) 7.3 (27.6) 10.9 (41.4) 56 61 68 38.6 2750
* The noise level values are based on anechoic room measurements at a distance of 1 meter in accordance with DIN 45645.

Parker Hannifin Corporation


4 Hydraulic Pump/Motor Division
Hydraulics Otsego, MI 49078
Variable Volume Piston Pumps
Ordering Information Series PV 016/020/023

PV 1
Multiple Pump Displace- Rotation Variations Shaft & Volume Thru-Shaft Multiple Seals Control Design
Pumps Variable ment Mounting Stop Option Pump Options Series
Piston Option Option (Not
Required
Code Seals When
N Nitrile Ordering)
Displacement
Code
(cc/rev.) V Viton
Code Volume
016 16 Stop Option
020 20 Max. Vol.
1 Multiple Pump
023 23 Stop Code
Option
1 Single Pump with
Shipping Cover
PV of Same Size
Code Rotation* 2
Mounted
R CW
Pump with SAE “A”
L CCW 4
Pilot Mounted
* As viewed from 5 Pump with SAE “AA”
shaft end. Pilot Mounted

Code Multiple Pumps Code Pump Variations Code Control Options


Omit Single 1 Standard • • • Standard Pressure Compensator
Factory mounted Adjustment Type
9* Reduced Stroke
— to rear of another S Screw With Nut
pump * Specify in cc/rev. Pressure Range
W 70-350 bar (1000-5075 PSI)
H 40-210 bar (600-3050 PSI)
D 10-140 bar (150-2050 PSI)
Option
P Standard Response
Code Shaft & Mounting Flange F Fast Response
Shaft Flange Size • • • Remote/Load Sense Compensator
A SAE Keyed SAE ‘B’ 2 & 4-Bolt Control Port
B SAE Spline SAE ‘B’ 2 & 4-Bolt C Single Threaded Port – 1/4" (dash-4) *
1 NG6/Cetop3 (D1VW) Pattern *
C* Metric Spline 80mm 2 & 4-Bolt
Z NG6 with Remote Pressure Valve Mounted **
K Metric Keyed 100mm 4-Bolt Compensator Control Type
* Used only when mounting two pumps of same frame R Remote Pressure
size together. F Load Sensing
Option
P Standard Response
F Fast Response
• L • Horsepower Compensator Control
Control Port
C NG6 with PVAC1PCS *S** Valve Mounted
Code Thru-Shaft Adapter Ports
Z NG6 with Remote Pressure Valve Mounted **
Thru-Shaft Capable Input Horsepower at 1800 RPM
T Side
Single Pump with Cover
A 3.0 (105 in-lb Torque)
Y SAE ‘AA’ Pilot (2.000) Side B 5.0 (175 in-lb Torque)
A SAE ‘A’ Pilot (3.250) Side C 7.5 (262 in-lb Torque)
H 80mm Pilot Side D 10.0 (350 in-lb Torque)
E 15.0 (525 in-lb Torque)
G 20.0 (700 in-lb Torque)
H 25.0 (875 in-lb Torque)
* Maximum pressure adjustment not included, but recommended.
** Valve to be mounted at factory must be ordered as a separate line
item. Consult factory.

Parker Hannifin Corporation


5 Hydraulic Pump/Motor Division
Hydraulics Otsego, MI 49078
Variable Volume Piston Pumps
Technical Information Series PV 016/020/023

Performance Curves

Fluid: Standard Hydraulic Oil 100 SSU @ 120°F (49°C)

PV023 @ 1200 RPM PV023 @ 1800 RPM


Volumetric Efficiency Volumetric Efficiency
20 40 100 24 40 100

Overall Efficiency Overall Efficiency


16 32 80 20 32 80
Horsepower HP

Horsepower HP
Delivery GPM

Delivery GPM
Efficiency - %

Efficiency - %
12 24 60 12 24 60

8 16
Flow /GPM 40 8 16 40
Input HP
Input HP at Full
at Full Stroke
4 8 20 4 8 20
Stroke
power power
Compens ated Horse Compens ated Horse
0 0 0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Pressure - PSI Pressure - PSI

NOTE: The efficiencies and data in the graphs are good WHERE:
only for pumps running at speeds shown and stroked to
Q = Actual Output Flow in GPM
maximum. To calculate approximate horsepower for
the other conditions, use the following formula: PSI = Pressure At Pump Outlet
CHp= Input Horsepower @ Full compensation
HP = [ Q x (PSI)
1714 ] + (CHp) @ 1800 RPM (from graph read at
operating pressure)

Actual GPM is directly proportional to drive speed and


maximum volume setting. Flow loss, however, is a
function of pressure only.

Parker Hannifin Corporation


6 Hydraulic Pump/Motor Division
Hydraulics Otsego, MI 49078
Variable Volume Piston Pumps
Technical Information Series PV 016/020/023

Dimensions - Standard
Millimeter equivalents for inch dimensions are shown in (**). 1.81
(46.0)
NOTES:
1. Pump shown is a clockwise rotation pump. For counterclockwise
rotation the inlet and outlet ports will be reversed with the gauge
and drain ports on the outlet side.
SAE “BB” SPLINE SHAFT
2. Pump shown with standard pressure compensator (P*S). 15T 16/32 PITCH
30° INVOLUTE

Splined Shaft

5.20
INLET PORT (130.0)
1-1/4" SAE 4 BOLT FLANGE LIFT HOOK THREAD 3.15
STANDARD PRESSURE 5/16-18UNC-2B (80.0)
SERIES (CODE 61)
1.26 2.05
MAXIMUM VOLUME (32.0)
ADJUSTMENT (52.1)
SENSITIVITY: 1.000 (25.4)
1.7 CC/REV ø .998 (25.3)
PER TURN
4.49
2.52 (114.0)
(64.0)
1.71
(43.4) 4.92
(125.0)

4.000 (101.6)
.65 ø 3.998 (101.5)
(16.5)

5.23
(132.8) CASE DRAIN PORT
SAE-10 STRAIGHT
THREAD O-RING PORT
5.99 (7/8-14UN-2B REF.) Rear View
(152.1)

6.88
SENSITIVITY: (174.8)
“W” - 950 PSI/TURN
“H” - 570 PSI/TURN
“D” - 380 PSI/TURN Top View

10.33 5.750
(262.4) (146.1)
3.536
GAUGE PORT (89.8)
.35 (8.9)
SAE-4 STRAIGHT
5.35 THREAD O-RING PORT
(135.8) (7/16-20UNF-2B REF.)

3.54 .25 (6.4)


(89.9) SQUARE .43 (10.9)
KEY 3.58 4 PLACES
2.24 (90.9)
(56.9)
1.57
(39.9)
3.536
(89.8)
6.00
(152.4) .67 .55 (14.0)
(17.0) 1.100 (27.9)
1.110 (28.2) 2 PLS.

ROTATION ARROW 3.33 3.33


NAMEPLATE (84.6) (84.6)
6.52
(165.6)
OUTLET PORT
3/4" SAE 4 BOLT FLANGE
6.71
(170.4)
Front View
HIGH PRESSURE SERIES 8.19
(CODE 62) (208.0)

Side View

Parker Hannifin Corporation


7 Hydraulic Pump/Motor Division
Hydraulics Otsego, MI 49078
Variable Volume Piston Pumps
Technical Information Series PV 016/020/023

Dimensions - Compensator Control Options (Remote, Load Sense, Horsepower)


Millimeter equivalents for inch dimensions are shown in (**).

MOUNTING INTERFACE
NG 6, CETOP 3

SENSITIVITY
200 PSI
PER TURN

CONTROL PORT - SAE-4 CONTROL PORT - SAE-4


STRAIGHT THREAD STRAIGHT THREAD
2.93 O-RING PORT 2.93 O-RING PORT
(74.4) (7/16-20UNF-2B REF.) (74.4) (7/16-20UNF-2B REF.)
*F1 ONLY
*RC and *FC *R1 and *F1
Compensator Control Compensator Control

4.49 4.49
(114.0) (114.0)

12.81
(325.4)
FROM
MOUNTING
SURFACE

*L* Horsepower Compensator

7.73
(196.3)

4.49
(114.0)

Parker Hannifin Corporation


8 Hydraulic Pump/Motor Division
Hydraulics Otsego, MI 49078
Variable Volume Piston Pumps
Technical Information Series PV 016/020/023

Dimensions - Thru-Shaft Options


Millimeter equivalents for inch dimensions are shown in (**).

Thru-Shaft
Option A B C D E F G
2.001/2.003 1.625 8.84
Y (50.83/50.88) (41.3) 5/16-18UNC 9 Tooth 20/40 Pitch (224.5) N/A N/A
3.251/3.253 2.094 8.84
A (82.58/82.63) (53.2) 3/8-16UNC 9 Tooth 16/32 Pitch (224.5) N/A N/A
3.150/3.152 DIN 5480 Spline 8.84 1.74
H (80.02/80.07) N/A N/A N25 x 1.5 x 15 (224.5) (44.2) 3/8-16UNC

5.00
(127.0)

B B E

G
F F D

Parker Hannifin Corporation


9 Hydraulic Pump/Motor Division
Hydraulics Otsego, MI 49078
Variable Volume Piston Pumps
Technical Information Series PV 032/040/046

Performance Information
Series PV, Pressure Compensated, Variable Volume,
Piston Pumps

Features
• High Strength Cast-Iron Housing for high reliability
and quiet operation
• Modular Controls for field convertability
• Large Control Piston for fast response
De-stroking in 45 mS
On-stroking in 70 mS
• Thru-Shaft Option with 100% thru torque capability
• 9 Piston Design to minimize ripple
• Multiple Pressure Control with valves mounted
directly on pump
Specifications
Controls Pressure Ratings: 5000 PSI (350 bar) Continuous
6000 PSI (420 bar) Peak
• Pressure Compensation
• Load Sensing
Speed Ratings: 600 to 2400 RPM
• Remote Pressure Compensation
• Adjustable Maximum Volume Stop
Inlet Condition: 230 PSI (16 bar)
• Electrohydraulic Pressure Maximum Inlet Charge
• Dual and Tri-Pressure 5 In. Hg. Max. Vacuum at
• Low Pressure Standby 1800 RPM
• Horsepower Limiting
Case Drain 30 PSI (2 bar) Maximum
Schematic Symbol Conditions:

(Basic Pump)
Operating -40°F to 160°F
Temp. Range: (-40°C to 70°C)

Housing Material: Cast Iron


Installation Data
See Installation Information on page 3 of this catalog Filtration: Maintain SAE Class 4 (ISO 16/13)
for specific recommendations pertaining to system
cleanliness, fluids, start-up, inlet conditions, shaft Mounting: SAE “C” 2 and 4-Bolt Flange
alignment, drain line restrictions and other important
factors relative to the proper installation and use of
these products.

Quick Reference Data Chart


Pump Delivery *Approx. Noise Levels dB(A) Horsepower At Max.
Pump Displacement @ 100 PSI (7 bar) @ Full Flow and 1500 RPM 1800 RPM, Max. Operating
cc/rev
Model in GPM (LPM) 1000 PSI 3000 PSI 5000 PSI Displacement & Speed
(in 3/rev) 5000 PSI (PRM)
1200 RPM 1800 RPM (69 bar) (207 bar) (345 bar)
PV032 32 (1.95) 10.1 (38.4) 15.2 (57.6) 59 63 69 48.3 2400
PV040 40 (2.44) 12.7 (48.0) 19.0 (72.0) 59 63 69 62.8 2400
PV046 46 (2.81) 14.6 (55.2) 21.9 (82.8) 59 63 69 72.4 2400

* The noise level values are based on anechoic room measurements at a distance of 1 meter in accordance with DIN 45645.

Parker Hannifin Corporation


10 Hydraulic Pump/Motor Division
Hydraulics Otsego, MI 49078
Variable Volume Piston Pumps
Ordering Information Series PV 032/040/046

PV 1
Multiple Pump Displace- Rotation Variations Shaft & Volume Thru-Shaft Multiple Seals Control Design
Pumps Variable ment Mounting Stop Option Pump Options Series
Piston Option Option (Not
Required
Code Seals When
N Nitrile Ordering)
Displacement
Code V Viton
(cc/rev.) Volume
Code
032 32 Stop Option
040 40 Multiple Pump
Max. Vol. Code
1 Option
046 46 Stop
Single Pump with
1
Shipping Cover
2 PV of Same Size
Mounted
Code Rotation *
Pump with SAE ‘A’
R CW 4
Pilot Mounted
L CCW
Pump with SAE ‘B’
7
* As viewed from Pilot Mounted
shaft end.

Code Control Options


Code Multiple Pumps Code Pump Variations • • • Standard Pressure Compensator
Adjustment Type
Omit Single Pump 1 Standard
S Screw With Nut
Factory mounted 9* Reduced Stroke Pressure Range
— to rear of another
pump * Specify in cc/rev. W 70-350 bar (1000-5075 PSI)
H 40-210 bar (600-3050 PSI)
D 10-140 bar (150-2050 PSI)
Option
P Standard Response
F Fast Response
• • • Remote/Load Sense Compensator
Code Shaft & Mounting Flange Control Port
Shaft Flange Size C Single Threaded Port – 1/4" (dash-4) *
1 NG6/Cetop3 (D1VW) Pattern *
A SAE Keyed SAE ‘C’ 2 & 4-Bolt
Z NG6 with Remote Pressure Valve Mounted **
B SAE Spline SAE ‘C’ 2 & 4-Bolt Compensator Control Type
C* Metric Spline 100mm 2 & 4-Bolt R Remote Pressure
K Metric Keyed 125mm 4-Bolt F Load Sensing
Option
* Used only when mounting two pumps of same frame
size together. P Standard Response
F Fast Response
• L • Horsepower Compensator Control
Control Port
C NG6 with PVAC1PCS* S** Valve Mounted
Z NG6 with Remote Pressure Valve Mounted **
Code Thru-Shaft Adapter Ports Input Horsepower at 1800 RPM
Thru-Shaft Capable C 7.5 (262 in-lb Torque)
T Side
Single Pump with Cover D 10.0 (350 in-lb Torque)
A SAE ‘A’ Pilot (3.250) Side E 15.0 (525 in-lb Torque)
B SAE ‘B’ Pilot (4.000) Side G 20.0 (700 in-lb Torque)
H 25.0 (875 in-lb Torque)
W* SAE ‘B’ Pilot (4.000) Side
K 30.0 (1050 in-lb Torque)
J 100mm Pilot Side
M 35.0 (1225 in-lb Torque)
*15 Tooth Spline S 50.0 (1750 in-lb Torque)
* Maximum pressure adjustment not included, but recommended.
** Valve to be mounted at factory must be ordered as a separate line
item. Consult factory.

Parker Hannifin Corporation


11 Hydraulic Pump/Motor Division
Hydraulics Otsego, MI 49078
Variable Volume Piston Pumps
Technical Information Series PV 032/040/046

Performance Curves

Fluid: Standard Hydraulic Oil 100 SSU @ 120°F (49°C)

PV046 @ 1200 RPM PV046 @ 1800 RPM


Volumetric Efficiency Volumetric Efficiency
30 100 100 40 100 100

Overall Efficiency Overall Efficiency


24 80 80 32 80 80
Horsepower HP

Horsepower HP
Delivery GPM

Delivery GPM
Efficiency - %

Efficiency - %
18 60 60 24 60 60
Flow/ GPM
Flow /GPM
12 40 40 16 40 40
Input HP Input HP
at Full at Full
Stroke Stroke
6 20 20 8 20 20

rsepowe r
Compe nsated Ho Horsepower
Compensated
0 0 0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Pressure - PSI Pressure - PSI

NOTE: The efficiencies and data in the graphs are good only WHERE:
for pumps running at speeds shown and stroked to maximum. Q = Actual Output Flow in GPM
To calculate approximate horsepower for the other conditions,
use the following formula: PSI = Pressure At Pump Outlet
CHp = Input Horsepower @ Full compensation
@ 1800 RPM (from graph read at
HP = [ Q x (PSI)
1714 ] + (CHp) operating pressure)

Actual GPM is directly proportional to drive speed and


maximum volume setting. Flow loss, however, is a function of
pressure only.

Parker Hannifin Corporation


12 Hydraulic Pump/Motor Division
Hydraulics Otsego, MI 49078
Variable Volume Piston Pumps
Technical Information Series PV 032/040/046

Dimensions — Standard
Millimeter equivalents or inch dimensions are shown in (**).
2.19
NOTES: (55.6)
1. Pump shown is a clockwise rotation pump. For counterclockwise
rotation the inlet and outlet ports will be reversed with the gauge
and drain ports on the outlet side.
SAE “C” SPLINE SHAFT
2. Pump shown with standard pressure compensator (P*S). 14 TOOTH 12/24 PITCH
30° INVOLUTE SPLINE

Splined Shaft

LIFT HOOK THREAD


5/16-18UNC-2B
6.14
INLET PORT (156.0)
1-1/2" SAE 4 BOLT FLANGE 3.62
STANDARD PRESSURE (91.9)
SERIES (CODE 61) 1.44
(36.6)
MAXIMUM VOLUME
ADJUSTMENT
SENSITIVITY:
2.3CC/REV. 2.91
(73.9) 5.12
PER TURN (130.1)
5.91
1.71 (150.1)
(43.4) 1.250 (31.8)
ø 1.248 (31.7)

.83
(21.1)
5.23
(132.8)
CASE DRAIN PORT
SAE-12 STRAIGHT
THREAD O-RING PORT
7.07 (1-1/16-12UN-2B REF.) Rear View
(179.6)
SENSITIVITY: 7.96
“W” - 950 PSI/TURN (202.2)
“H” - 570 PSI/TURN
“D” - 380 PSI/TURN
Top View

7.125
(180.9)
11.50 2.59
(292.1) (65.8) 4.508
(114.5)
GAUGE PORT .50
SAE-4 STRAIGHT (12.7)
THREAD O-RING PORT
(7/16-20UNF-2B REF.) .312 (7.9)
SAE KEY
5.98 .55 (14.0)
(151.9) 4 PLACES
4.17 4.25
(105.9) 2.68 (108.0) ø5.000 (127.0)
(68.1) 1.97 4.998 (126.9)
(50.0)
4.508
(114.5)
7.13
(181.1) .67 1.391 (35.3) .71 (18.0)
(17.0) 1.381 (35.1) 2 PLS.

NAMEPLATE ROTATION
OUTLET PORT 7.60 ARROW 4.32 4.32
1" SAE 4 BOLT FLANGE (193.0) (109.7) (109.7)
HIGH PRESSURE SERIES 7.68
(CODE 62) (195.1) Front View
9.39
(238.5)

Side View

Parker Hannifin Corporation


13 Hydraulic Pump/Motor Division
Hydraulics Otsego, MI 49078
Variable Volume Piston Pumps
Technical Information Series PV 032/040/046

Dimensions – Compensator Control Options (Remote, Load Sense, Ho rsepower)


Millimeter equivalents for inch dimensions are shown in (**).

MOUNTING INTERFACE
NG 6, CETOP 3

SENSITIVITY
200 PSI
PER TURN

CONTROL PORT - SAE-4 CONTROL PORT - SAE-4


STRAIGHT THREAD STRAIGHT THREAD
O-RING PORT O-RING PORT
2.93 2.93
(7/16-20UNF-2B REF.) (7/16-20UNF-2B REF.)
(74.4) (74.4)
*F1 ONLY
*RC and *FC *R1 and *F1
Compensator Control Compensator Control

5.12 5.12
(130.0) (130.0)

14.25
(361.9)
FROM
MOUNTING
SURFACE

*L* Horsepower Compensator

8.20
(208.3)

5.12
(130.0)

Parker Hannifin Corporation


14 Hydraulic Pump/Motor Division
Hydraulics Otsego, MI 49078
Variable Volume Piston Pumps
Technical Information Series PV 032/040/046

Dimensions – Thru-Shaft Options


Millimeter equivalents for inch dimensions are shown in (**).

Thru-Shaft
Option A B C D E F G

A 3.251/3.253 2.094 N/A 3/8-16UNC — 9 Tooth 20/40 Pitch 10.28


(82.58/82.63) (53.19) (261.1)
B 4.001/4.003 2.875 1.786 1/2-13UNC 3/8-16UNC 13 Tooth 16/32 Pitch 10.28
(101.63/101.68) (73.03) (45.36) (261.1)
W 4.001/4.003 2.875 1.786 1/2-13UNC 3/8-16UNC 15 Tooth 16/32 Pitch 10.28
(101.63/101.68) (73.03) (45.36) (261.1)
J 3.938/3.940 N/A 2.244 N/A 1/2-13UNC DIN 5480 Spline 10.28
(100.02/100.07) (57.00) N32 x 1.5 x 20 (261.1)

6.54
(166.1)

B B
C C G

Parker Hannifin Corporation


15 Hydraulic Pump/Motor Division
Hydraulics Otsego, MI 49078
Variable Volume Piston Pumps
Technical Information Series PV 063/080/092

Performance Information
Series PV, Pressure Compensated, Variable Volume,
Piston Pumps

Features
• High Strength Cast-Iron Housing for high reliability
and quiet operation
• Modular Controls for field convertability
• Large Control Piston for fast response
De-stroking in 45 mS
On-stroking in 70 mS
• Thru-Shaft Option with 100% thru torque capability
• 9 Piston Design to minimize ripple
• Multiple Pressure Control with valves mounted
directly on pump
Specifications
Controls Pressure Ratings: 5000 PSI (350 bar) Continuous
• Pressure Compensation 6000 PSI (420 bar) Peak
• Load Sensing
• Remote Pressure Compensation Speed Ratings: 600 to 2100 RPM (PV063)
600 to 2000 RPM (PV080)
• Adjustable Maximum Volume Stop
600 to 1900 RPM (PV092)
• Electrohydraulic Pressure
• Dual and Tri-Pressure Inlet Conditions: 230 PSI (16 bar)
• Low Pressure Standby Maximum Inlet Charge
• Horsepower Limiting 5 In. Hg. Max. Vacuum at
1800 RPM
Schematic Symbol
(Basic Pump) Case Drain 30 PSI (2 bar) Maximum
Conditions:

Operating -40°F to 160°F


Temp. Range: (-40°C to 70°C)

Installation Data Housing Material: Cast Iron


See Installation Information on page 3 of this catalog
for specific recommendations pertaining to system Filtration: Maintain SAE Class 4 (ISO 16/13)
cleanliness, fluids, start-up, inlet conditions, shaft
alignment, drain line restrictions and other important Mounting: SAE “D” 2 and 4-Bolt Flange
factors relative to the proper installation and use of
these products.

Quick Reference Data Chart


Pump Delivery *Approx. Noise Levels dB(A) Horsepower At Max.
Pump Displacement @ 100 PSI (7 bar) @ Full Flow and 1500 RPM 1800 RPM, Max. Operating
cc/rev
Model in GPM (LPM) 1000 PSI 3000 PSI 5000 PSI Displacement & Speed
(in3/rev) 5000 PSI (PRM)
1200 RPM 1800 RPM (69 bar) (207 bar) (345 bar)
PV063 63 (3.84) 20.0 (75.6) 30.0 (113.4) 63 68 73 99.8 2100
PV080 80 (4.88) 25.4 (96.0) 38.0 (144.0) 63 68 73 122.3 2000
PV092 92 (5.61) 29.2 (110.4) 43.8 (165.6) 63 68 73 144.8 1900

* The noise level values are based on anechoic room measurements at a distance of 1 meter in accordance with DIN 45645.

Parker Hannifin Corporation


16 Hydraulic Pump/Motor Division
Hydraulics Otsego, MI 49078
Variable Volume Piston Pumps
Ordering Information Series PV 063/080/092

PV
Multiple Pump Displace- Rotation Variations Shaft & Volume Thru-Shaft Multiple Seals Control Design
Pumps Variable ment Mounting Stop Option Pump Options Series
Piston Option Option (Not
Required
When
Code Seals Ordering)
N Nitrile
Displacement
Code V Viton
(cc/rev.)
063 63
080 80 Code Multiple Pump Option
092 92 Single Pump with
1
Shipping Cover
2 PV of Same Frame Size
Mounted
Pump with SAE ‘A’ Pilot
Code Multiple Pumps Code Rotation* 4
Mounted
Omit Single Pump R CW
Pump with SAE ‘B’ Pilot
L CCW 7
Factory mounted Mounted
— to rear of another * As viewed from Pump with SAE ‘C’ Pilot
pump 8
shaft end. Mounted

Code Control Options


Code Pump Variations • • • Standard Pressure Compensator
1 Standard Adjustment Type
S Screw With Nut
9* Reduced Stroke Pressure Range
* Specify in cc/rev. W 70-350 Bar (1000-5075 PSI)
H 40-210 Bar (600-3050 PSI)
D 10-140 Bar (150-2050 PSI)
Option
Code Shaft & Mounting Flange
P Standard Response
Shaft Flange Size F Fast Response
A SAE Keyed SAE ‘D’ 2 & 4-Bolt • • • Remote/Load Sense Compensator
B SAE Spline SAE ‘D’ 2 & 4-Bolt Control Port
C Single Threaded Port – 1/4" (dash-4) *
C* Metric Spline 125mm 2 & 4-Bolt
1 NG6/Cetop3 (D1VW) Pattern *
K Metric Keyed 160mm 4-Bolt Z NG6 with Remote Pressure Valve Mounted **
* Used only when mounting two pumps of same frame Compensator Control Type
size together. R Remote Pressure
F Load Sensing
Option
P Standard Response
Volume Stop F Fast Response
Code
Option • L • Horsepower Compensator Control
Control Port
1 Max. Vol. Stop
C NG6 with PVAC1PCS* S** Valve Mounted
Z NG6 with Remote Pressure Valve Mounted **
Input Horsepower at 1800 RPM
E 15.0 (525 in-lb Torque)
Code Thru-Shaft Adapter Ports G 20.0 (700 in-lb Torque)
Thru-Shaft Capable H 25.0 (875 in-lb Torque)
T Side
Single Pump with Cover K 30.0 (1050 in-lb Torque)
A SAE ‘A’ Pilot (3.250) Side M 35.0 (1225 in-lb Torque)
S 50.0 (1750 in-lb Torque)
B SAE ‘B’ Pilot (4.000) Side T 60.0 (2100 in-lb Torque)
W* SAE ‘B’ Pilot (4.000) Side U 75.0 (2625 in-lb Torque)
C SAE ‘C’ Pilot (5.000) Side W 90.0 (3150 in-lb Torque)

K 125mm Pilot Side * Maximum pressure adjustment not included, but recommended.
** Valve to be mounted at factory must be ordered as a separate line
*15 Tooth Spline item. Consult factory.

Parker Hannifin Corporation


17 Hydraulic Pump/Motor Division
Hydraulics Otsego, MI 49078
Variable Volume Piston Pumps
Technical Information Series PV 063/080/092

Performance Curves

Fluid: Standard Hydraulic Oil 100 SSU @ 120°F (49°C)

PV092 @ 1200 RPM PV092 @ 1800 RPM


Volumetric Efficiency Volumetric Efficiency
50 200 100 100 250 100

40 160 Overall Efficiency 80 80 200 Overall Efficiency 80


Horsepower HP

Horsepower HP
Delivery GPM

Delivery GPM
Efficiency - %

Efficiency - %
30 120 Flow /GPM 60 60 150 60

Flow /GPM
20 80 40 40 100 40

Input HP Input HP
at Full at Full
10 40 20 20 50 Stroke 20
Stroke

Compensated Hors
epower Compensat ed Horsepower
0 0 0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Pressure - PSI Pressure - PSI

NOTE: The efficiencies and data in the graphs are WHERE:


good only for pumps running at speed shown and Q = Actual Output Flow in GPM
stroked to maximum. To calculate approximate
PSI = Pressure At Pump Outlet
horsepower for the other conditions, use the following
formula: CHp = Input Horsepower @ Full Compensation
@ 1800 RPM (from graph read at
HP = [ Q x (PSI)
1714 ] + (CHp) operating pressure)

Actual GPM is directly proportional to drive speed


and maximum volume setting. Flow loss, however, is
a function of pressure only.

Parker Hannifin Corporation


18 Hydraulic Pump/Motor Division
Hydraulics Otsego, MI 49078
Variable Volume Piston Pumps
Technical Information Series PV 063/080/092

Dimensions — Standard
Millimeter equivalents for inch dimensions are shown in (**). 2.95
(74.9)
NOTE: SAE “D” SPLINE
13T 8/16DP
1. Pump shown is a clockwise rotation pump. For counterclockwise 30° INVOLUTE
rotation the inlet and outlet ports will be reversed with the gauge and
drain ports on the outlet side.
2. Pump shown with standard pressure compensator (P*S).

Splined Shaft
INLET PORT
2" SAE 4 BOLT FLANGE LIFT HOOK THREAD
STANDARD PRESSURE 5/16-18UNC-2B
SERIES (CODE 61) 1.71
(43.4)
7.64
MAXIMUM VOLUME (194.1)
ADJUSTMENT
SENSITIVITY: 4.33
3.8CC/REV. (110.0)
PER TURN

ø 1.750 (44.5)
1.749 (44.4)
6.26
1.71 (159.0)
(43.4) 3.74
(95.0)

5.23 1.18
(132.8) (30.0)

CASE DRAIN PORT


SAE-12 STRAIGHT 7.48
THREAD O-RING PORT (190.0)
9.43 (1-1/16-12UN-2B REF.)
(239.5)
SENSITIVITY: 10.32
“W” - 950 PSI/TURN (262.13)
“H” - 570 PSI/TURN Rear View
“D” - 380 PSI/TURN Top View

13.98 3.94 9.000


(355.1) (100.1) (228.6)
6.364
.47 (161.6)
GAUGE PORT (11.9)
SAE-4 STRAIGHT
THREAD O-RING PORT
(7/16-20UNF-2B REF.)

7.12
(180.8) 5.16
(131.1)
5.31
(134.9) 3.44
(87.4) ø 6.000 (152.4)
9.06 5.998 (152.3)
1.89
(230.1) (48.0)
6.364
(161.6

1.02 1.946 (49.4)


(25.9) 1.936 (49.2)

OUTLET PORT NAMEPLATE ROTATION


1-1/4" SAE ARROW
4 BOLT FLANGE 5.29 5.29
9.92 (134.4) (134.4)
HIGH PRESSURE (252.0)
SERIES (CODE 62)
9.96 Front View
(253.0)
11.74
(298.2)

Side View

Parker Hannifin Corporation


19 Hydraulic Pump/Motor Division
Hydraulics Otsego, MI 49078
Variable Volume Piston Pumps
Technical Information Series PV 063/080/092

Dimensions - Compensator Control Options (Remote, Load Sense, Horsepower)


Millimeter equivalents for inch dimensions are shown in (**).

MOUNTING INTERFACE
NG 6, CETOP 3

SENSITIVITY
200 PSI
PER TURN

CONTROL PORT - SAE-4 CONTROL PORT - SAE-4


STRAIGHT THREAD STRAIGHT THREAD
O-RING PORT O-RING PORT
2.93 2.93
(7/16-20UNF-2B REF.) (7/16-20UNF-2B REF.)
(74.4) (74.4)
*F1 ONLY
*RC and *FC *R1 and *F1
Compensator Control Compensator Control

6.26 6.26
(436.9) (436.9)

17.20
(436.9)
FROM
MOUNTING
SURFACE

*L* Horsepower Compensator

8.99
(228.3)
6.26
(436.9)

Parker Hannifin Corporation


20 Hydraulic Pump/Motor Division
Hydraulics Otsego, MI 49078
Variable Volume Piston Pumps
Technical Information Series PV 063/080/092

Dimensions - Thru-Shaft Options


Millimeter equivalents for inch dimensions are shown in (**).

Thru-Shaft
Option A B C D E F G
3.251/3.253 2.094 12.84
A N/A 3/8-16UNC N/A 9 Tooth 16/32 Pitch
(82.57/82.62) (53.18) (326.1)
4.001/4.003 2.875 1.786 12.84
B 1/2-13UNC 1/2-13UNC 13 Tooth 16/32 Pitch
(101.62/101.67) (73.02) (45.36) (326.1)
4.001/4.003 2.875 1.786 12.84
W 1/2-13UNC 1/2-13UNC 15 Tooth 16/32 Pitch
(101.62/101.67) (73.02) (45.36) (326.1)
5.001/5.003 3.560 2.254 12.84
C 5/8-11UNC 1/2-13UNC 14 Tooth 12/24 Pitch
(127.02/127.07) (90.42) (57.25) (326.1)
4.922/4.924 2.783 DIN 5480 Spline 12.84
K N/A N/A 5/8-11UNC
(125.02/125.07) (70.68) N40 x 1.5 x 25 (326.1)

8.31
(211.1)

B B G

C
D
A
F

Parker Hannifin Corporation


21 Hydraulic Pump/Motor Division
Hydraulics Otsego, MI 49078
Variable Volume Piston Pumps
Technical Information Series PV 130/180

Performance Information
Series PV 130/180 Pressure Compensated, Variable
Volume, Piston Pumps

Features
• High Strength Cast-Iron Housing for reliable and
quiet operation
• Modular Controls for field convertibility
• Large Control Piston for smooth/fast response...
De-stroking in 90 mS
On-stroking in 145 mS
• Multiple Pressure Control with valves mounted
directly on pump

Controls
• Pressure Compensation
Specifications
• Load Sensing
Pressure Ratings: 5000 PSI (350 bar) Continuous
• Remote Pressure Compensation 6000 PSI (420 bar) Peak
• Adjustable Maximum Volume Stop
• Electrohydraulic Pressure Speed Ratings: 750 to 1800 RPM
• Dual and Tri-Pressure
• Low Pressure Standby Inlet Condition: 725 PSI (50 bar) Maximum
• Horsepower Limiting 3 In-Hg Vacuum at 1500 RPM
0 In-Hg Vacuum at 1800 RPM
Schematic Symbol
Case Drain 7 PSI (.5 bar) Maximum
(Basic Pump) Conditions:

Operating -40°F to 160°F


Temp. Range: (-40°C to 70°C)

Installation Data
Housing Material: Cast Iron
See Installation Information on page 3 of this catalog
for specific recommendations pertaining to system
cleanliness, fluids, start-up, inlet conditions, shaft Filtration: Maintain SAE Class 4 (ISO 16/13)
alignment, drain line restrictions and other important
factors relative to the proper installation and use of Mounting: SAE “D” 4-Bolt Flange
these products.

Quick Reference Data Chart


Pump Delivery *Approx. Noise Levels dB(A)
Pump Displacement @ 100 PSI (7 bar) @ Full Flow and 1500 RPM Input Horsepower At
cc/rev 1800 RPM, Max. Pressure
Model in GPM (LPM) 1000 PSI 3000 PSI 5000 PSI
(in3/rev) & Displacement
1200 RPM 1800 RPM (69 bar) (207 bar) (345 bar)
PV130 130 (7.93) 41.2 (156) 61.8 (234) 77 82 83 205
PV180 180 (10.98) 57.1 (216) 85.6 (324) 79 84 86 284
* Since many variables such as mounting, tank style, plant layout, etc., effect noise levels, it cannot be assumed that the above readings wil be
equal to those in the field. The above values are for guidance in selecting the proper pump. Noise levels are A-weighted, mean sound pressure
levels at 1 meter from the pump, measured and recorded in accordance with applicable ISO and NFPA standards.

Parker Hannifin Corporation


22 Hydraulic Pump/Motor Division
Hydraulics Otsego, MI 49078
Variable Volume Piston Pumps
Ordering Information Series PV 130/180

PV R 1 T 1
Variable Series Rotation Pump Shaft Displacement Multiple Seals Compensator Design
Piston & Size Variations Limited Thru-Shaft Pump Series
Pump Adapter/ Option (Not
Pump Required
When
Ordering)
Code Rotation
R CW Code Seals
N Nitrile
V Viton

Displacement
Code
(cc/rev.) Code Multiple Pump Option
130 130 1 Single Pump
180 180

Code Compensator
Code Pump Variations • • • Standard Pressure Compensator
1 Standard Adjustment Type
S Screw With Nut
9* Reduced Stroke
Pressure Range
* Specify reduced
W 70-350 bar (1000-5000 PSI)
displacement in cc/rev.
when ordering. H 40-210 bar (580-3050 PSI)
D 10-140 bar (150-2000 PSI)
Option
F Fast Response
• • • Remote Pressure Compensator
Code Shaft & Mounting Flange Control Port
Shaft Flange Size C SAE Dash-4 (7/16-20UNF) *
1 NG6/Cetop3 Pattern *
D SAE Keyed SAE “D” 4-Bolt
Z NG6 with Pressure Valve Mounted **
K Metric Keyed 160mm 4-Bolt
Control Type
R Remote Compensator
F Load Sensing Compensator
Option
F Fast Response
• L • Horsepower Compensator
Displacement Control Port
Code
Limiter C NG6 with PVAC1PCS *S** Valve Mounted
1 Max. Volume Stop Z NG6 with Pressure Valve Mounted **
HP setting at 1800 RPM
K 30.0 (1050 in-lb Torque)
M 35.0 (1225 in-lb Torque)
PV130

S 50.0 (1750 in-lb Torque)


T 60.0 (2100 in-lb Torque)
PV180

Thru-Shaft U 75.0 (2625 in-lb Torque)


Code
Adapter/Pump W 90.0 (3150 in-lb Torque)
T Single Pump Y 120.0 (4200 in-lb Torque)
Z 150.0 (5250 in-lb Torque)
* Maximum pressure adjustment not included, but recommended.
** Valve to be mounted at factory must be ordered as a separate line
item. Consult factory.

Parker Hannifin Corporation


23 Hydraulic Pump/Motor Division
Hydraulics Otsego, MI 49078
Variable Volume Piston Pumps
Technical Information Series PV 130/180

Performance Curves

Fluid: Standard Hydraulic Oil 100 SSU @ 120°F (49°C)

PV130 @ 1200 RPM PV130 @ 1800 RPM


Volumetric Efficiency Volumetric Efficiency
50 200 100 75 300 100
Overall Efficiency Overall Efficiency

40 160 80 60 240 80
Flow/GPM Flow/GPM

Horsepower HP
Horsepower HP

Delivery GPM
Delivery GPM

Efficiency - %
Efficiency - %
30 120 60 45 180 60
er e r
p ow pow
rse rse
20 80
Ho 40 30 120
Ho 40
w w
ll Flo ll Flo
10 40 Fu 20 15 60 Fu 20

power power
Compensated Horse Compensated Horse
0 0 0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Pressure - PSI Pressure - PSI

PV180 @ 1200 RPM PV180 @ 1800 RPM


Volumetric Efficiency Volumetric Efficiency
75 300 100 100 500 100

Overall Efficiency Overall Efficiency


60 240 80 80 400 Flow/ GPM 80
Horsepower HP
Horsepower HP

Flow/GPM
Delivery GPM
Delivery GPM

Efficiency - %
Efficiency - %

45 180 60 60 300 60
r
we we
r
e po po
30 120
H ors 40 40 200
ors
e 40
w H
Flo low
Fu
ll ll F
15 60 20 20 100 Fu 20

power Compensated Horsepo


wer
Compensated Horse
0 0 0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Pressure - PSI Pressure - PSI

NOTE: The efficiencies and data in the graphs are


accurate for pumps running at 1200 or 1800 RPM and
maximum stroke. To calculate approximate horsepower
for the other conditions, use the following formula:

HP = [ GPM x (PSI)
1714
] + Compensated HP

Parker Hannifin Corporation


24 Hydraulic Pump/Motor Division
Hydraulics Otsego, MI 49078
Variable Volume Piston Pumps
Technical Information Series PV 130/180

Dimensions – Standard
Millimeter equivalents for inch dimensions are shown in (**).
NOTES:
1. Pump shown is a clockwise rotation pump. For counterclockwise 12.00
rotation the inlet and outlet ports will be reversed with the gauge (304.8)
and drain ports on the outlet side. TO MOUNTING
FLANGE
2. Pump shown with standard pressure compensator (P*S).

INLET PORT
SAE 2-1/2"
STANDARD
PRESSURE SERIES
4-BOLT FLANGE
(CODE 61)

View A
Inlet Port
SAE-16 STRAIGHT
THREAD O-RING PORT
(1 5/16-12UNF-2B REF.)
8.42
(213.9)
7/16-14UNC-2A 1.89 6.46
(48.0) View (164.1)
A
7.56
(192.0)
1.37 4.33
(34.8) (110.0)
7.68
(195.1)

3.94
ø 1.750 (44.5) (100.1)
5.23 1.748 (44.4)
(132.8)

ø 6.000 (152.4)
5.998 (152.3)
7.87 (199.9)
12.30 (312.4)

Top View Rear View

16.80 (426.7) MAX.

15.67 (398.0)

14.17 (359.9)
.31 (7.9) 2.94
(74.7)
.50 (12.7)

7/16 SAE
KEY
ø 9.000
(228.6)
OUTLET
PORT
SAE 1-1/4" ø 1.946 (49.49)
HIGH 1.936 (49.17)
PRESSURE
SERIES
4-BOLT
FLANGE
(CODE 62)
.83
(21.1)

11.61 (294.9)
Front View
Side View

Parker Hannifin Corporation


25 Hydraulic Pump/Motor Division
Hydraulics Otsego, MI 49078
Variable Volume Piston Pumps
Technical Information Series PV250

Performance Information
Series PV250 Pressure Compensated, Variable
Volume, Piston Pumps

Features
• High Strength Cast-Iron Housing for reliable and
quiet operation
• Modular Controls for field convertibility
• Large Control Piston for smooth/fast response...
De-stroking in 90 mS
On-stroking in 145 mS
• Multiple Pressure Control with valves mounted
directly on pump

Controls
• Pressure Compensation
Specifications
• Load Sensing
Pressure Ratings: 5000 PSI (350 bar) Continuous
• Remote Pressure Compensation
6000 PSI (420 bar) Peak
• Adjustable Maximum Volume Control
• Electrohydraulic Pressure Control
Speed Ratings: 750 to 1800 RPM
• Dual and Tri-Pressure
• Low Pressure Standby Inlet Condition: 725 PSI (50 bar) Maximum
• Horsepower Limiting 3 In-Hg Vacuum at 1500 RPM
0 In-Hg Vacuum at 1800 RPM
Schematic Symbol
Case Drain 7 PSI (.5 bar) Maximum
(Basic Pump) Conditions:

Operating -40°F to 160°F


Temp. Range: (-40°C to 70°C)

Installation Data
Housing Material: Cast Iron
See Installation Information on page 3 of this catalog
for specific recommendations pertaining to system
cleanliness, fluids, start-up, inlet conditions, shaft Filtration: Maintain SAE Class 4 (ISO 16/13)
alignment, drain line restrictions and other important
factors relative to the proper installation and use of Mounting: SAE “E” 4-Bolt Flange
these products.

Quick Reference Data Chart


Pump Delivery *Approx. Noise Levels dB(A)
Displacement Input Horsepower At
Pump @ 100 PSI (7 bar) @ Full Flow and 1500 RPM
Model cc/rev in GPM (LPM) 1800 RPM, Max. Pressure
(in3/rev) 1000 PSI 3000 PSI 5000 PSI & Displacement
1200 RPM 1800 RPM (69 Bar) (207 Bar) (345 Bar)
PV250 250 (15.26) 79.3 (300) 118.8 (450) 81 86 88 321

* Since many variables such as mounting, tank style, plant layout, etc., effect noise levels, it cannot be assumed that the above readings wil be
equal to those in the field. The above values are for guidance in selecting the proper pump. Noise levels are A-weighted, mean sound pressure
levels at 1 meter from the pump, measured and recorded in accordance with applicable ISO and NFPA standards.

Parker Hannifin Corporation


26 Hydraulic Pump/Motor Division
Hydraulics Otsego, MI 49078
Variable Volume Piston Pumps
Ordering Information Series PV250

PV R 1 T 1
Variable Series Rotation Pump Shaft Displace- Thru-Shaft Multiple Seals Compensator Design
Piston & Size Variations ment Adapter/ Pump Series
Pump Limited Pump Option (Not
Required
When
Ordering)
Code Seals
N Nitrile
Displacement V Viton
Code
(cc/rev.)
250 250

Code Multiple Pump Option


1 Single Pump

Code Rotation Code Compensator


R CW • • • Standard Pressure Compensator
Adjustment Type
S Screw With Nut
Pressure Range
W 70-350 bar (1000-5000 PSI)
H 40-210 bar (580-3050 PSI)
Code Pump Variations
D 10-140 bar (150-2000 PSI)
1 Standard Option
9* Reduced Stroke F Fast Response
* Specify reduced displacement
in cc/rev. when ordering.
• • • Remote Pressure Compensator
Control Port
C SAE Dash-4 (7/16-20UNF) *
1 NG6/Cetop3 Pattern *
Z NG6 with Pressure Valve Mounted **
Control Type
R Remote Compensator
Code Shaft & Mounting Flange F Load Sensing Compensator
Shaft Size Flange Size Option
D SAE Keyed SAE “E” 4-Bolt F Fast Response
K Metric Keyed 200mm 4-Bolt • L • Horsepower Compensator
Control Port
C NG6 with PVAC1PCS* S** Valve Mounted
Z NG6 with Pressure Valve Mounted **
HP setting at 1800 RPM
S 50.0 (1750 in-lb Torque)
Code Displacement Limiter T 60.0 (2100 in-lb Torque)
1 Maximum Volume Stop U 75.0 (2625 in-lb Torque)
W 90.0 (3150 in-lb Torque)
Y 120.0 (4200 in-lb Torque)
Z 150.0 (5250 in-lb Torque)
2 175.0 (6125 in-lb Torque)
3 200.0 (7000 in-lb Torque)
Thru-Shaft
Code 4 250.0 (8750 in-lb Torque)
Adapter/Pump
T Single Pump * Maximum pressure adjustment not included, but recommended.
** Valve to be mounted at factory must be ordered as a separate line
item. Consult factory.

Parker Hannifin Corporation


27 Hydraulic Pump/Motor Division
Hydraulics Otsego, MI 49078
Variable Volume Piston Pumps
Technical Information Series PV250

Performance Curves
Fluid: Standard Hydraulic Oil 100 SSU @ 120°F (49°C)

PV250 @ 1200 RPM PV250 @ 1800 RPM


Volumetric Efficiency Volumetric Efficiency
100 375 100 125 500 100

Flow/GPM
Overall Efficiency Overall Efficiency
80 300 80 100 400 80
Flow/GPM

Horsepower HP
Horsepower HP

Delivery GPM
Delivery GPM

Efficiency - %
Efficiency - %
r
60 225
e r 60 75 300
owe 60
ow ep
se
p rs
r Ho
40 150 Ho 40 50 200
ow
40
w l
ll Flo l lF
Fu Fu
20 75 20 25 100 20

Compensated Ho
rsepower Horsepower
Compensated
0 0 0 0 0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000
Pressure - PSI Pressure - PSI
NOTE: The efficiencies and data in the graphs are
accurate for pumps running at 1200 or 1800 RPM and
maximum stroke. To calculate approximate horsepower
HP = [ GPM x (PSI)
1714 ] + Compensated HP

for the other conditions, use the following formula:

Dimensions - Compensator Control Options (Remote, Load Sense, Horsepower)


Millimeter equivalents for inch dimensions are shown in (**).
MOUNTING INTERFACE
NG 6, CETOP 3

SENSITIVITY
200 PSI
PER TURN

CONTROL PORT - SAE-4 CONTROL PORT - SAE-4


STRAIGHT THREAD STRAIGHT THREAD
2.93 O-RING PORT 2.93 O-RING PORT
(74.4) (7/16-20UNF-2B REF.) (74.4) (7/16-20UNF-2B REF.)
*F1 ONLY
*RC and *FC *R1 and *F1
Compensator Control Compensator Control

10.00
9.34 9.34 (254.0)
(237.2) (237.2)

Parker Hannifin Corporation


28 Hydraulic Pump/Motor Division
Hydraulics Otsego, MI 49078
Variable Volume Piston Pumps
Technical Information Series PV250

Dimensions – Standard
Millimeter equivalents for inch dimensions are shown in (**).
NOTES:
1. Pump shown is a clockwise rotation pump. For counterclockwise
rotation the inlet and outlet ports will be reversed with the gauge and
drain ports on the outlet side.
2. Pump shown with standard pressure compensator (P*S). 12.99 (329.9)

12.80 (325.1)
GAUGE PORT 6.89 (175.0)
SAE-4 STRAIGHT
THREAD O-RING PORT 6.00 (152.4)
(7/16-20UNF-2B REF.)
INLET PORT
SAE 3 1/2
STANDARD PRESSURE 2.36
SERIES 4-BOLT FLANGE (59.9) 10.17 9.34
(CODE 61) (258.3) (237.2)

5.37
ø 6.500 (165.10) (136.4)
6.498 (165.05)

11.02
8.40 (279.9)
(213.4)

.50
(12.7)
5.51
(139.9)
CASE DRAIN PORT
SAE-20 STRAIGHT
THREAD O-RING PORT
(1 5/8-12UN-2B REF.)
9.84 (249.9)
16.79 (426.5)
1.48 5/8-11UNC-2B
(37.6) X 1.26 DP -4 PLS
Top View Rear View
ALTERNATE CASE
DRAIN PORT FOR
VERTICAL MOUNTS
SAE-8 STR. THREAD
O-RING PORT
LIFT HOOK (3/4-16UN-2B REF.)
2 PLACES
22.20 (563.8) 6.93 (176.0)
20.18 (528.3) 5.08
(129.0)
7.36 (193.0)

12.50
(317.5)
1.02
(25.9)

5.40
(137.2) ø 2.000 (50.80)
1.998 (50.74)

11.00
(279.4)

2.22
(56.4)

1.00
(25.4) 11.00 (279.4)
6.50 (16.51) 5.98 (151.9) .63
(16.0) Front View
15.87 (403.1) 3.84
(97.5)
18.60 (472.4)
OUTLET PORT
SAE 1 1/2
HIGH PRESSURE Side View
SERIES 4-BOLT
(CODE 62)

Parker Hannifin Corporation


29 Hydraulic Pump/Motor Division
Hydraulics Otsego, MI 49078
Variable Volume Piston Pumps
Control Options Series PV
Standard Pressure Compensated Control (P*S)
The unique design feature of the PV series pump is This causes the bias spring and rod area forces to be
the single servo piston design. It is mechanically greater and pushes the swash plate to maximum
connected to the swash plate via a bolt through the tilt angle.
center of the servo piston threaded into a nut. The nut When the outlet pressure reaches the setting of the
is then connected to the swash plate with a large compensator spring, the compensator spool will move
single chain link. The servo piston is like a small to the right allowing outlet pressure oil to be metered
hydraulic cylinder allowing for fast and accurate into the bore end of the servo piston. This metered oil
positioning of the swash plate. generates a sufficient force to power the bore end of
By means of internal drilling, outlet pressure is the servo piston and overcome the swash plate forces
connected directly to the rod area end of the servo and reduce the tilt angle of the swash plate and
piston and to the bore area end of the servo piston correspondingly the pumps outlet flow.
through the compensator valve. To control the swash If the outlet pressure decreases, the compensator
plate position, the hydraulic forces of the bore end of spring will move the compensator spool back to the
the servo piston must overcome the bias spring force left, closing off outlet pressure to the bore end of the
and the rod end forces. With the pump in the position servo piston and venting it to the pump case. As the
shown, the compensator spring pushes the pressure in the bore end of the servo piston decreases,
compensator spool to the left which connects the the bias spring and rod end forces become greater
pressure in the bore end of the servo piston to case. and return the swash plate to maximum tilt.

COMPENSATOR COMPENSATOR
SPOOL SPRING

COMPENSATOR
ADJUSTING
SCREW

ROD
AREA
SWASH
PLATE

BORE
AREA FLOW
OUTLET
PORT

PRESSURE

INLET
PORT

Parker Hannifin Corporation


30 Hydraulic Pump/Motor Division
Hydraulics Otsego, MI 49078
Variable Volume Piston Pumps
Control Options Series PV

Remote Pressure Compensator Control (*RC and *R1)


The function of the pump with a remote pressure flows through it causing a pressure drop across the
compensator control is the same as the standard orifice and a pressure differential across the
pressure compensated control except for the device compensator spool. When the differential pressure
that controls the maximum pump pressure. reaches the setting of the spring, the spool will move
The adjustment is no longer made with the adjusting and destroke the pump. By using a selector valve
screw on the pump compensator. As shown in the and more than one relief valve, several maximum
figure, outlet pressure is connected to the spring cavity pressure settings can be selected. Also an electrically
via internal drilling. At maximum swash plate tilt angle, modulated relief valve can be used for infinitely
the pressure on each end of the spool is the same variable maximum pressure selection.
and the spring keeps the compensator spool pushed An extra feature of the *R1 compensator is an NG6
to the left. An external relief valve is connected to the machined interface on top of the compensator
spring cavity of the compensator. When the outlet housing. This allows for direct mounting on the pump
pressure reaches the setting of the relief valve, oil of manapak relief valves and electrical solenoid valves.

COMPENSATOR SPRING EXTERNAL


ORIFICE SPOOL CAVITY RELIEF VALVE

SWASH
PLATE

FLOW
OUTLET
PORT

PRESSURE

INLET
PORT NOTE:
If the control port is blocked,
the pump will be a fixed
displacement pump.

Parker Hannifin Corporation


31 Hydraulic Pump/Motor Division
Hydraulics Otsego, MI 49078
Variable Volume Piston Pumps
Control Options Series PV
Flow Control (Load Sense) Compensator (*FC and *F1)
For some applications, it is desirable to maintain a As the variable orifice is closed, it causes a pressure
constant flow regardless of input shaft speed or pump drop between the pump outlet and the compensator
working pressure. The flow control (load sense) spring cavity. When the differential pressure across
compensator was designed to meet exactly those the compensator spool is equal to the spring setting,
requirements. the compensator spool will move to the right and meter
This control requires an orifice (fixed or variable) in oil into the bore end of the servo piston and destroke
the outlet port of the pump. As shown in the figure, a the pump to the desired flow. With a constant pressure
variable orifice is being used with a sense line, drop across the variable orifice, the pump flow will
downstream of the orifice, being run back to the spring remain the same regardless of the pressure demands
cavity of the compensator. With the variable orifice of the system.
fully open, there is negligible pressure drop across A separate pressure relief valve must be used
the orifice and, therefore, both ends of the to limit the maximum pump pressure on both the
compensator spool will see the same pressure. With *FC and *F1 compensator. On the *FC compensator,
the compensator spool being pressure balanced, the it must be installed externally, but with the * F1
additional spring force will keep the spool pushed to compensator, it can be installed directly to the NG6
the left, venting the bore end of the servo piston, and machined interface on top of the compensator
the pump will be at maximum swash plate tilt angle. housing.

SENSE COMPENSATOR SPRING


LINE SPOOL CAVITY

VARIABLE
ORIFICE
SWASH
PLATE

SYSTEM FLOW
OUTLET
PRESSURE PORT

BORE
END
PRESSURE

INLET
PORT

Parker Hannifin Corporation


32 Hydraulic Pump/Motor Division
Hydraulics Otsego, MI 49078
Variable Volume Piston Pumps
Control Options Series PV

Horsepower Compensator Control (*LC) connect outlet pressure to the spring cavity of the *F1
The horsepower requirement to operate a pump is compensator and the direct acting relief mounted in
the product of flow rate, pressure, and pump efficiency. the horsepower control block. With the compensator
With a constant flow rate, the horsepower requirement spool pressure balanced, the additional spring force
increases with pressure. When the work pressure will keep the spool pushed to the left and the pump
reaches the pump compensating pressure, the flow will be a maximum swash plate tilt angle. When the
working pressure reaches the setting of relief valve in
rate will reduce along with the horsepower
the HP control block, oil will flow through the orifice in
requirement. In application, minimizing the input power
the gauge port causing a pressure differential across
while maximizing the pump output is very important.
the compensator. When the differential is equal to the
In many of these applications, the system requirements
compensator spring setting, the compensator spool
are well suited for higher flows at lower pressures
will move to the right and meter oil into the bore end
and lower flows at higher pressures. Both conditions
of the servo piston and destroke the pump. As the
require a relatively low input horsepower, but with a
pump starts to destroke, the servo piston and cam
standard pressure compensated pump, it must go to
piston will move to the right. As the cam piston moves
maximum pressure at maximum flow before the flow
to the right, it increases the spring setting of the relief
(and input horsepower) will reduce.
valve in the HP control block, which in turn increases
The horsepower control was designed for these the pressure in the compensator spring cavity. The
applications. The horsepower control on the PV pump cam piston and relief valve in the HP control block is
uses the load sense compensator (*FC or *F1) along a mechanical/pressure feedback system between the
with a horsepower control block. Shown in the figure swash plate tilt angle (pump flow) and the pressure in
below, the horsepower block consists of a cam piston the compensator spring cavity (outlet pressure minus
that moves with the servo piston and a direct acting differential). By machining a special profile on the
relief that rides on the side of the cam piston. The side of the cam piston, the relationship of outlet flow
compensator used in the figure is the *F1 with a direct versus system pressure as shown in the graph can
acting relief mounted on top of the compensator be controlled. The advantage of this control is to be
housing using the NG6 machined interface. Tubing is able to use a smaller prime mover and still meet all
then plumbed externally using the gauge port to the pressure and flow requirements of the system.

COMPENSATOR COMPENSATOR
SPOOL ADJUSTMENT CONSTANT
HORSEPOWER
CURVE
EXTERNAL SPRING
TUBING CAVITY

FLOW
GAUGE PORT
WITH ORIFICE

*F1
COMPENSATOR
DIRECT BODY PRESSURE
ACTING
RELIEF
SERVO PISTON

SWASH
PLATE

CAM–PISTON OUTLET
PORT

HORSEPOWER
CONTROL
BLOCK

INLET
PORT

Parker Hannifin Corporation


33 Hydraulic Pump/Motor Division
Hydraulics Otsego, MI 49078
Offer of Sale
The items described in this document and other documents or descriptions provided by Parker Hannifin Corporation, its subsidiaries and its
authorized distributors, are hereby offered for sale at prices to be established by Parker Hannifin Corporation, its subsidiaries and its
authorized distributors. This offer and its acceptance by any customer (“Buyer”) shall be governed by all of the following Terms and
Conditions. Buyer’s order for any such item, when communicated to Parker Hannifin Corporation, its subsidiaries or an authorized
distributor (“Seller”) verbally or in writing, shall constitute acceptance of this offer.
1. Terms and Conditions of Sale: All descriptions, quotations, proposals, 8. Buyer’s Property: Any designs, tools, patterns, materials, drawings,
offers, acknowledgments, acceptances and sales of Seller’s products are confidential information or equipment furnished by Buyer, or any other items
subject to and shall be governed exclusively by the terms and conditions which become Buyer’s property, may be considered obsolete and may be
stated herein. Buyer’s acceptance of any offer to sell is limited to these terms destroyed by Seller after two (2) consecutive years have elapsed without
and conditions. Any terms or conditions in addition to, or inconsistent with Buyer placing an order for the items which are manufactured using such
those stated herein, proposed by Buyer in any acceptance of an offer by property. Seller shall not be responsible for any loss or damage to such
Seller, are hereby objected to. No such additional, different or inconsistent property while it is in Seller’s possession or control.
terms and conditions shall become part of the contract between Buyer and
Seller unless expressly accepted in writing by Seller. Seller’s acceptance of 9. Taxes: Unless otherwise indicated on the face hereof, all prices and
any offer to purchase by Buyer is expressly conditional upon Buyer’s assent charges are exclusive of excise, sales, use, property, occupational or like
to all the terms and conditions stated herein, including any terms in addition taxes which may be imposed by any taxing authority upon the manufacture,
to, or inconsistent with those contained in Buyer’s offer. Acceptance of sale or delivery of the items sold hereunder. If any such taxes must be paid
Seller’s products shall in all events constitute such assent. by Seller or if Seller is liable for the collection of such tax, the amount thereof
shall be in addition to the amounts for the items sold. Buyer agrees to pay all
2. Payment: Payment shall be made by Buyer net 30 days from the date of such taxes or to reimburse Seller therefore upon receipt of its invoice. If Buyer
delivery of the items purchased hereunder. Amounts not timely paid shall bear claims exemption from any sales, use or other tax imposed by any taxing
interest at the maximum rate permitted by law for each month or portion authority, Buyer shall save Seller harmless from and against any such tax,
thereof that the Buyer is late in making payment. Any claims by Buyer for together with any interest or penalties thereon which may be assessed if the
omissions or shortages in a shipment shall be waived unless Seller receives items are held to be taxable.
notice thereof within 30 days after Buyer’s receipt of the shipment.
10. Indemnity For Infringement of Intellectual Property Rights: Seller
3. Delivery: Unless otherwise provided on the face hereof, delivery shall be shall have no liability for infringement of any patents, trademarks, copyrights,
made F.O.B. Seller’s plant. Regardless of the method of delivery, however, trade dress, trade secrets or similar rights except as provided in this Part 10.
risk of loss shall pass to Buyer upon Seller’s delivery to a carrier. Any delivery Seller will defend and indemnify Buyer against allegations of infringement of
dates shown are approximate only and Seller shall have no liability for any U.S. patents, U.S. trademarks, copyrights, trade dress and trade secrets
delays in delivery. (hereinafter “Intellectual Property Rights”). Seller will defend at its expense
and will pay the cost of any settlement or damages awarded in an action
4. Warranty: Seller warrants that the items sold hereunder shall be free from brought against Buyer based on an allegation that an item sold pursuant to
defects in material or workmanship for a period of 18 months from date of this contract infringes the Intellectual Property Rights of a third party. Seller’s
shipment from Parker Hannifin Corporation. THIS WARRANTY COMPRISES obligation to defend and indemnify Buyer is contingent on Buyer notifying
THE SOLE AND ENTIRE WARRANTY PERTAINING TO ITEMS PRO- Seller within ten (10) days after Buyer becomes aware of such allegations of
VIDED HEREUNDER. SELLER MAKES NO OTHER WARRANTY, GUAR- infringement, and Seller having sole control over the defense of any allega-
ANTEE, OR REPRESENTATION OF ANY KIND WHATSOEVER. ALL tions or actions including all negotiations for settlement or compromise. If an
OTHER WARRANTIES, INCLUDING BUT NOT LIMITED TO, MERCHANT- item sold hereunder is subject to a claim that it infringes the Intellectual
ABILITY AND FITNESS FOR PURPOSE, WHETHER EXPRESS, IMPLIED, Property Rights of a third party, Seller may, at its sole expense and option,
OR ARISING BY OPERATION OF LAW, TRADE USAGE, OR COURSE OF procure for Buyer the right to continue using said item, replace or modify said
DEALING ARE HEREBY DISCLAIMED. item so as to make it noninfringing, or offer to accept return of said item and
NOTWITHSTANDING THE FOREGOING, THERE ARE NO WARRANTIES return the purchase price less a reasonable allowance for depreciation.
WHATSOEVER ON ITEMS BUILT OR ACQUIRED WHOLLY OR PAR- Notwithstanding the foregoing, Seller shall have no liability for claims of
TIALLY, TO BUYER’S DESIGN OR SPECIFICATIONS. infringement based on information provided by Buyer, or directed to items
delivered hereunder for which the designs are specified in whole or part by
5. Limitation of Remedy: SELLER’S LIABILITY ARISING FROM OR IN Buyer, or infringements resulting from the modification, combination or use in
ANY WAY CONNECTED WITH THE ITEMS SOLD OR THIS CONTRACT a system of any item sold hereunder. The foregoing provisions of this Part 10
SHALL BE LIMITED EXCLUSIVELY TO REPAIR OR REPLACEMENT OF shall constitute Seller’s sole and exclusive liability and Buyer’s sole and
THE ITEMS SOLD OR REFUND OF THE PURCHASE PRICE PAID BY exclusive remedy for infringement of Intellectual Property Rights.
BUYER, AT SELLER’S SOLE OPTION. IN NO EVENT SHALL SELLER BE
LIABLE FOR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAM- If a claim is based on information provided by Buyer or if the design for an item
AGES OF ANY KIND OR NATURE WHATSOEVER, INCLUDING BUT NOT delivered hereunder is specified in whole or in part by Buyer, Buyer shall
LIMITED TO LOST PROFITS ARISING FROM OR IN ANY WAY CON- defend and indemnify Seller for all costs, expenses or judgements resulting
NECTED WITH THIS AGREEMENT OR ITEMS SOLD HEREUNDER, from any claim that such item infringes any patent, trademark, copyright, trade
WHETHER ALLEGED TO ARISE FROM BREACH OF CONTRACT, EX- dress, trade secret or any similar right.
PRESS OR IMPLIED WARRANTY, OR IN TORT, INCLUDING WITHOUT 11. Force Majeure: Seller does not assume the risk of and shall not be liable
LIMITATION, NEGLIGENCE, FAILURE TO WARN OR STRICT LIABILITY. for delay or failure to perform any of Seller’s obligations by reason of
6. Changes, Reschedules and Cancellations: Buyer may request to circumstances beyond the reasonable control of Seller (hereinafter “Events
modify the designs or specifications for the items sold hereunder as well as of Force Majeure”). Events of Force Majeure shall include without limitation,
the quantities and delivery dates thereof, or may request to cancel all or part accidents, acts of God, strikes or labor disputes, acts, laws, rules or regula-
of this order, however, no such requested modification or cancellation shall tions of any government or government agency, fires, floods, delays or
become part of the contract between Buyer and Seller unless accepted by failures in delivery of carriers or suppliers, shortages of materials and any
Seller in a written amendment to this Agreement. Acceptance of any such other cause beyond Seller’s control.
requested modification or cancellation shall be at Seller’s discretion, and shall 12. Entire Agreement/Governing Law: The terms and conditions set forth
be upon such terms and conditions as Seller may require. herein, together with any amendments, modifications and any different terms
7. Special Tooling: A tooling charge may be imposed for any special tooling, or conditions expressly accepted by Seller in writing, shall constitute the entire
including without limitations, dies, fixtures, molds and patterns, acquired to Agreement concerning the items sold, and there are no oral or other
manufacture items sold pursuant to this contract. Such special tooling shall representations or agreements which pertain thereto. This Agreement shall
be and remain Seller’s property notwithstanding payment of any charges by be governed in all respects by the law of the State of Ohio. No actions arising
Buyer. In no event will Buyer acquire any interest in apparatus belonging to out of sale of the items sold hereunder or this Agreement may be brought by
Seller which is utilized in the manufacture of the items sold hereunder, even either party more than two (2) years after the cause of action accrues.
if such apparatus has been specially converted or adapted for such manufac-
ture and notwithstanding any charges paid by Buyer. Unless otherwise
agreed, Seller shall have the right to alter, discard or otherwise dispose of any
special tooling or other property in its sole discretion at any time.

Parker Hannifin Corporation


34 Hydraulic Pump/Motor Division
Hydraulics Otsego, MI 49078
Parker Hannifin Corporation
17325 Euclid Avenue
Cleveland, Ohio 44112-1290
Parker Hannifin
Telephone: (216) 531-3000
Telex: 980636
Corporation
Fax: (216) 383-9414

About Parker Hannifin Corporation The Fluid Connectors Group designs,


Parker Hannifin is a leading global manufactures and markets hose,
motion-control company dedicated fittings, flexible connectors, instrumen-
tation products and associated compo-
to delivering premier customer ser-
nents used in fluid systems. It serves
vice. A Fortune 200 corporation, customers in the industrial, aerospace,
we are listed on the New York Stock marine, transportation, agriculture, and
Exchange with PH as our symbol. military markets.
Our components and systems com-
prise over 1,000 product lines that
control motion in a wide spectrum The Motion & Control Group designs,
produces and markets the full spectrum
of essential uses in some 1,200 indus-
of components and systems to provide
trial and aerospace markets. Parker force, motion & control for industrial,
is the only manufacturer to offer its mobile, marine, and energy related
customers a choice of hydraulic, machinery and equipment. Hydraulic,
pneumatic, and electromechanical pneumatic, and electro-mechanical
motion-control solutions. Our Com- solutions are offered.
pany has the largest distribution
network in its field, with over 6,000 The Automotive & Refrigeration Group is a
distributors serving more than leading supplier of flow-control and fluid
300,000 customers worldwide. handling components, gerotors, and of
systems support to worldwide refrigera-
Parker’s Charter tion, air conditioning and automotive
customers. Supplies high-pressure steam
To be a leading worldwide manufac- valves, general-purpose solenoids, and
turer of components and systems high-pressure cylinders.
for the builders and users of durable
goods. More specifically, we will
design, market and manufacture The Seal Group designs, manufactures
products controlling motion, flow and distributes industrial and
and pressure. We will achieve commercial sealing devices and related
profitable growth through premier products by providing superior quality
and emphasizing total customer
customer service.
satisfaction in each of its markets.

Product Information
Parker Hannifin’s North American
customers seeking product infor-
The Filtration Group is a leading
mation, the location of a nearby worldwide manufacturer and marketer
distributor, or repair services will of quality filtration and clarification
receive prompt attention by calling products. Its goal is to provide
the Parker Product Information customers with the best value, top
Center at our toll-free number: quality, sound technical support, and
1-800-C-PARKER (1-800-272-7537). global availability.
In the UK, a similar service is avail-
able by calling : 0500-103-203.
The Aerospace Group is a leader in the
development, design, manufacture and
servicing of hydraulic and fuel control
systems and components for aerospace
and related high-technology markets. It
serves both commercial and military
aviation customers around the world.
Parker Hannifin Corporation Catalog 2600-600-2/USA, 5M
Hydraulic Pump/Motor Division 6/97 IGS Printed in U.S.A.
100 Parker Drive
Otsego, Michigan 49078
Hydraulics Tel: (616) 694-9411
Fax: (616) 694-4638
Web site: http://www.parker.com

You might also like