1. INTERFACES 1-1

1.1 iPASOLINK VR 4 and Designated Slots . . . . . . . . . . . . . . . . . . . . . . . . 1-1


1.1.1 Front View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
1.1.2 Card Slots on iPASOLINK VR 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
1.2 Location of Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
1.2.1 Fundamental Cards. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
1.2.1.1 MC-AV (Main Card) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
1.2.1.2 FAN-CV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
1.2.2 Cards for Universal Slots. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
1.2.2.1 MODEM-EA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
1.2.2.2 MODEM-AV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
1.2.2.3 MODEM-EV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
1.2.2.4 MSE-A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
1.2.2.5 AUX-A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
1.2.2.6 STM1-A Through . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
1.2.2.7 16E1-A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
1.2.2.8 GbE4e-AV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7
1.2.2.9 GbE4f-AV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7
1.2.2.10 GbE-A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8

2. SPECIFICATION 2-1

2.1 Interface Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1


2.1.1 Ethernet Traffic Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
2.1.2 E1 Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
2.1.3 STM-1 Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
2.1.4 Radio Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
2.1.5 Management Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
2.1.6 Housekeeping Control and Alarm Interface . . . . . . . . . . . . . . . . . . . . . . 2-2
2.1.7 Other Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2

iPASOLINK VR 4: SPECIFICATIONS GGS-000396-07E


March 2017

2017-12-06 Gobierno San Juan © NEC Corporation 2015-2017


– ii/END – CONTENTS

2.2 Supported Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3


2.2.1 Radio Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
2.2.1.1 Modulation and Radio Capacity
— On-Board MODEM and MODEM-EA/EV . . . . . . . . . . . . . . . . . 2-4
2.2.1.2 Modulation and Radio Capacity
— MODEM-AV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
2.2.2 TDM Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
2.2.3 ETH Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6
2.2.4 MPLS-TP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7
2.2.5 Management Plane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7
2.2.6 Synchronization. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8
2.2.7 Performance Monitor and Logs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8
2.3 Traffic Interface Specifications and Standards . . . . . . . . . . . . . . . . . . 2-9
2.3.1 STM-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9
2.3.2 1000BASE-X . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10
2.3.3 10GBASE-R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11

3. SYSTEM PERFORMANCES 3-1

3.1 Power Consumption and Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1


3.1.1 IDU/MDP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
3.1.2 Fundamental Cards. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
3.1.3 Cards for Universal Slots. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
3.2 Environmental Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
3.2.1 Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
3.2.2 Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
3.3 Power Line Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
3.3.1 Input Voltage and Connector. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
3.3.2 Rated Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
3.4 Others. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5

GGS-000396-07E iPASOLINK VR 4: SPECIFICATIONS

2017-12-06 Gobierno San Juan © NEC Corporation 2015-2017


INTERFACES 1-1

1. INTERFACES

1.1 iPASOLINK VR 4 and Designated Slots

1.1.1 Front View

1.1.2 Card Slots on iPASOLINK VR 4

[ON-BOARD
MODEM]

Slots for fundamental cards that must be mounted.

Slot # Slots for option cards, which can be left vacant.

iPASOLINK VR 4: SPECIFICATIONS GGS-000396-07E

2017-12-06 Gobierno San Juan © NEC Corporation 2015-2017


1-2 INTERFACES

1.2 Location of Terminals

1.2.1 Fundamental Cards

1.2.1.1 MC-AV (Main Card)

➀ ➁ ➂➃ ➄
➇ ➈➉
11
12 13

➅ ➆

Ref. # Indication Element Description

➀ Grounding Screw Grounding terminal; screw shaft diameter is 4 mm.

➁ IF1 TNC Connector IF Terminal connecting to the Outdoor Unit (ODU); SYS1

IF2 TNC Connector IF Terminal connecting to the Outdoor Unit (ODU); SYS2

➂ CALL Push Button Press the button to call the opposing site by OW.

➃ EOW Pin Jack Connecting terminal for OW Headset.

➄ CLK High Density D-Sub (Optional) Terminal for Clock Signal input/output. (15 pins)
Connector

➅ ODU PWR IF1 Rocker Switch Switch to supply/shut-down power to ODU 1 (using IF1).

ODU PWR IF2 Rocker Switch Switch to supply/shut-down power to ODU 2 (using IF2).

➆ MEM USB Type-A Connecting terminal for USB memory device. (Supporting
a memory device only.)

➇ 2M IN/OUT MDR Connector E1 Traffic Signal Input/Output

➈ LCT RJ-45 Connector Ethernet port for connecting WebLCT. (Supporting 10/
100BASE-TX; Auto-Negotiation, Auto-MDI/MDIX.)

➉ NMS RJ-45 Connector Terminal for connecting to DCN Network upstream.


(Supporting 10/100BASE-TX; Auto-Negotiation,
Auto-MDI/MDIX)

GGS-000396-07E IPASOLINK VR 4: SPECIFICATIONS

2017-12-06 Gobierno San Juan © NEC Corporation 2015-2017


INTERFACES 1-3

Ref. # Indication Element Description

11 NE/1 RJ-45 Connector Two-Way Use: Terminal for connecting DCN Network
downstream., or traffic Ethernet signal input/output Port 1.
(Supporting 10/100/1000BASE-TX; Auto-Negotiation,
Auto-MDI/MDIX)

2, 3, 4 RJ-45 Connector Traffic Ethernet signal input/output Port 2 to Port 4.


(Supporting 10/100/1000BASE-TX; Auto-Negotiation,
Auto-MDI/MDIX)

12 5, 6 SFP Module Port Traffic Ethernet Signal 1000BASE-SX/LX

7, 8 SFP+ Module Port Two-Way Use: Traffic Ethernet Signal1000BASE-SX/LX, or


10GBASE-SR/LR/ER.

13 SELV PWR 1/2 DK3100 Power Input Terminal for IDU. SELV, –48 V DC. PWR 2 is
an optional.

1.2.1.2 FAN-CV

Ref. # Indication Element Description

—— —— —— FAN-CV provides no front-accessible terminals.

iPASOLINK VR 4: SPECIFICATIONS GGS-000396-07E

2017-12-06 Gobierno San Juan © NEC Corporation 2015-2017


1-4 INTERFACES

1.2.2 Cards for Universal Slots

1.2.2.1 MODEM-EA

 Available Slots: All Universal Slots (#3, #4 and #5)

➀ ➁ ➂ ➃

Ref. # Indication Element Description

➀ IF TNC Connector IF Terminal connecting to the Outdoor Unit (ODU).

➁ Cross Slot Screw Grounding terminal; screw shaft diameter is 4 mm.

➂ XIF IEC-MIN Connector Connecting terminals for configuring XPIC.

➃ ODU PWR Toggle Switch Switch to supply power to ODU.

1.2.2.2 MODEM-AV

 Available Slots: Restricted (Slots #3 and #4)

➀ ➁ ➂

Ref. # Indication Element Description

➀ IF TNC Connector IF Terminal connecting to the Outdoor Unit (ODU).

➁ Cross Slot Screw Grounding terminal; screw shaft diameter is 4 mm.

➂ ODU PWR Toggle Switch Switch to supply power to ODU.

GGS-000396-07E IPASOLINK VR 4: SPECIFICATIONS

2017-12-06 Gobierno San Juan © NEC Corporation 2015-2017


INTERFACES 1-5

1.2.2.3 MODEM-EV
 Available Slots: All Universal Slots (#3, #4 and #5)
➀ ➁ ➂

Ref. # Indication Element Description

➀ IF TNC Connector IF Terminal connecting to the Outdoor Unit (ODU).

➁ Cross Slot Screw Grounding terminal; screw shaft diameter is 4 mm.

➂ ODU PWR Toggle Switch Switch to supply power to ODU.

1.2.2.4 MSE-A

 Available Slots: One MSE Card per IDU on Any Universal Slots

Ref. # Indication Element Description

—— —— —— MSE-A Card provides no front-accessible terminals.

1.2.2.5 AUX-A

 Available Slots: One AUX-A Card per IDU on Any Universal Slots

Ref. # Indication Element Description

ALM/EOW/NE2 High-Density D-Sub Terminal for Housekeeping and Cluster alarms.


Connector Four input channels, six output channels. (44 pins)
➀ NOTE: The uses of EOW and NE1 interfaces are
currently not available.

iPASOLINK VR 4: SPECIFICATIONS GGS-000396-07E

2017-12-06 Gobierno San Juan © NEC Corporation 2015-2017


1-6 INTERFACES

1.2.2.6 STM1-A Through


 Available Slots: All Universal Slots (#3, #4 and #5)

SFP Module Ports ➀ ➁ CLASS 1 LASER PRODUCT

Ref. # Indication Element Description

➀ OUT IN 1 SFP Module Port STM-1 Optical Port 1; using SFP.

➁ OUT IN 2 SFP Module Port STM-1 Optical Port 2; using SFP.

1.2.2.7 16E1-A
 Available Slots: All Universal Slots (#3, #4 and #5)

Ref. # Indication Element Description

➀ 2M IN/OUT MDR Connector E1 Traffic Signal Input/Output

GGS-000396-07E IPASOLINK VR 4: SPECIFICATIONS

2017-12-06 Gobierno San Juan © NEC Corporation 2015-2017


INTERFACES 1-7

1.2.2.8 GbE4e-AV
 Available Slots: All Universal Slots (#3, #4 and #5)

➀ ➁ ➂ ➃

Ref. # Indication Element Description

➀ OUT IN 1 RJ-45 Connector Traffic Terminal for GbE Interface 1.

➁ OUT IN 2 RJ-45 Connector Traffic Terminal for GbE Interface 2.

➂ OUT IN 3 RJ-45 Connector Traffic Terminal for GbE Interface 3.

➃ OUT IN 4 RJ-45 Connector Traffic Terminal for GbE Interface 4.

1.2.2.9 GbE4f-AV
 Available Slots: All Universal Slots (#3, #4 and #5)

➀ ➁ ➂ ➃ CLASS 1 LASER PRODUCT

Ref. # Indication Element Description

➀ OUT IN 1 SFP Module Port Traffic Terminal Port for GbE Interface 1.

➁ OUT IN 2 SFP Module Port Traffic Terminal Port for GbE Interface 2.

➂ OUT IN 3 SFP Module Port Traffic Terminal Port for GbE Interface 3.

➃ OUT IN 4 SFP Module Port Traffic Terminal Port for GbE Interface 4.

iPASOLINK VR 4: SPECIFICATIONS GGS-000396-07E

2017-12-06 Gobierno San Juan © NEC Corporation 2015-2017


1-8/END INTERFACES

1.2.2.10 GbE-A

 Available Slots: All Universal Slots (#3, #4 and #5)

➀ ➁ ➂ ➃ CLASS 1 LASER PRODUCT

Ref. # Indication Element Description

➀ 1 RF-45 Connector Traffic Terminal for GbE Interface.

➁ 2 RF-45 Connector Traffic Terminal for GbE Interface.

➂ 3 SFP Module Port Traffic Terminal for GbE Interface.

➃ 4 SFP Module Port Traffic Terminal for GbE Interface.

GGS-000396-07E iPASOLINK VR 4: SPECIFICATIONS

2017-12-06 Gobierno San Juan © NEC Corporation 2015-2017


SPECIFICATION 2-1

2. SPECIFICATION

2.1 Interface Capacity

iPASOLINK VR 4 supports various interfaces conforming to the ITU-T Standards


and IEEE Standards:

2.1.1 Ethernet Traffic Interfaces


INTERFACE SPEC CONNECTOR SUPPORTING CARD

10GBASE-SR/LR/ER 10 Gbps LC (SFP+ Module) 2 on MC-AV (Two of four ports on MC-AV,


that are Ports #7 and #8, can interface
1000BASE-SX/LX 1.25 Gbps LC (SFP Module) either with 10GBASE-SR/LR/ER (SFP+) or
with 1000BASE-SX/LX (SFP) by choice.)

1000BASE-SX/LX/CWDM 1.25 Gbps LC (SFP Module) 2 on MC-AV (The rate of Ports #5 and #6
[802.3] on MC-AV are fixed.)

2 on GbE-A (up to 6 ports per IDU)

4 on GbE4f-AV (up to 12 ports per IDU)

Up to 8 ports in total per IDU.

10/100/1000BASE-T/TX (TX) 125 Mbps RJ-45 Up to 4 on MC-AV. (Port #1 can also be


(T) 10 Mbps used to connect with DCN by choice.)

4 on GbE4f-AV (up to 12 ports per IDU)

2 on GbE-A (up to 8 ports per IDU)

Up to 12 ports in total per IDU

2.1.2 E1 Interface
INTERFACE SPEC CONNECTOR SUPPORTING CARD

HDB-3 [G.703] 16 × E1 (2.048 Mbps) MDR68 16 on MC-AV


75 ohms, 120 ohms (selectable) 16 on 16E1-A (up to 48 per IDU)

Up to 64 channels in total per IDU

2.1.3 STM-1 Interface


INTERFACE SPEC CONNECTOR SUPPORTING CARD

S-1.1 / L-1.1 [G.957] 2 × 155.52 Mbps LC (SFP Module) 2 on STM1-A Through (up to 6 ports per IDU)
CWDM

iPASOLINK VR 4: SPECIFICATIONS GGS-000396-07E

2017-12-06 Gobierno San Juan © NEC Corporation 2015-2017


2-2 SPECIFICATION

2.1.4 Radio Interface


INTERFACE SPEC CONNECTOR DESCRIPTION

IF (IDU-ODU Interface) –48 V DC, TX IF, TNC 2 on MC-AV (On-Board MODEM)


RX IF, ODU SV
1 on MODEM-EA/EV (up to 3 ports per IDU)

1 on MODEM-AV (up to 2 ports per IDU)

Up to 5 ports in total per IDU

2.1.5 Management Interfaces


INTERFACE SPEC CONNECTOR SUPPORTING CARD

10/100/1000BASE-T/TX (TX) 125 Mbps RJ-45 1 (LCT) on MC-AV


(T) 10 Mbps 1 (NMS) on MC-AV

1 (NE1) on MC-AV (This port, that is


Port #5, can be used for the traffic
Ethernet by choice)

2.1.6 Housekeeping Control and Alarm Interface


INTERFACE SPEC CONNECTOR DESCRIPTION

AUX Input Photo Coupler D-Sub 44 4 Inputs on AUX-A; for


Housekeeping Alarms

AUX Output Photo Coupler D-Sub 44 6 Outputs on AUX-A; for


Housekeeping Controls

2.1.7 Other Interfaces


INTERFACE SPEC CONNECTOR DESCRIPTION

Oderwire Headset 4-Wire Voice Channel Pin Jack 1 (EOW) on MC-AV

External Storage USB Type-A Female 1 (MEM) on MC-AV

GGS-000396-07E : SPECIFICATIONS

2017-12-06 Gobierno San Juan © NEC Corporation 2015-2017


SPECIFICATION 2-3

2.2 Supported Functions


iPASOLINK VR 4 supports the following functions:

2.2.1 Radio Functions


Functions Supported Items

Channel Separation MODEM-EA/EV


7 MHz, 14 MHz, 28 MHz, 40 MHz, 56 MHz
On-Board MODEM

MODEM-AV 7 MHz, 14 MHz, 28 MHz, 40 MHz, 56 MHz, 80 MHz,


112 MHz

Modulation MODEM-EA/EV 9 Modulation Schemes are changeable: QPSK, 16QAM,


32QAM, 64QAM, 128QAM, 256QAM, 512QAM,
On-Board MODEM 1024QAM, 2048QAM.

MODEM-AV 10 Modulation Schemes are changeable: QPSK, 16QAM,


32QAM, 64QAM, 128QAM, 256QAM, 512QAM,
1024QAM, 2048QAM. 4096QAM.

Configuration 1+0 Up to 5 systems per IDU


(Up to 2 per MC-MV, 1 per MODEM-EA/EV/AV)

1+1 SWG Up to 2 Switch Groups per IDU

2 × RTA Group Up to 2 configurations per IDU

1+0 XPIC Group Up to 2 configurations per IDU

1+1 XPIC Group Up to 1 configuration per IDU

iPASOLINK VR 4: SPECIFICATIONS GGS-000396-07E

2017-12-06 Gobierno San Juan © NEC Corporation 2015-2017


2-4 SPECIFICATION

2.2.1.1 Modulation and Radio Capacity


— On-Board MODEM and MODEM-EA/EV

Radio Capacity
Modulation
CS: 7 MHz CS: 14 MHz CS: 28 MHz CS: 40 MHz CS: 56 MHz

2048QAM N/A 100MB 300MB 400MB 500MB

1024QAM 50MB 100MB 200MB 300MB 500MB

512QAM 50MB 100MB 200MB 300MB 400MB

256QAM 50MB 100MB 200MB 300MB 400MB

128QAM 50MB 100MB 150MB 200MB 300MB

64QAM 50MB 100MB 150MB 150MB 300MB

32QAM 50MB 50MB 100MB 150MB 200MB

16QAM 50MB 50MB 100MB 100MB 200MB

QPSK 50MB 50MB 50MB 50MB 100MB

2.2.1.2 Modulation and Radio Capacity


— MODEM-AV

Radio Capacity
Modulation
CS: CS: CS: CS: CS: CS: CS:
7 MHz 14 MHz 28 MHz 40 MHz 56 MHz 80 MHz 112 MHz

4096QAM N/A N/A 300MB 400MB 600MB N/A N/A

2048QAM N/A 100MB 300MB 400MB 500MB 600MB 1000MB

1024QAM 50MB 100MB 200MB 300MB 500MB 600MB 800MB

512QAM 50MB 100MB 200MB 300MB 400MB 600MB 800MB

256QAM 50MB 100MB 200MB 300MB 400MB 500MB 600MB

128QAM 50MB 100MB 150MB 200MB 300MB 500MB 600MB

64QAM 50MB 100MB 150MB 150MB 300MB 400MB 500MB

32QAM 50MB 50MB 100MB 150MB 200MB 300MB 500MB

16QAM 50MB 50MB 100MB 100MB 200MB 300MB 400MB

QPSK 50MB 50MB 50MB 50MB 100MB 100MB 200MB

GGS-000396-07E : SPECIFICATIONS

2017-12-06 Gobierno San Juan © NEC Corporation 2015-2017


SPECIFICATION 2-5

2.2.2 TDM Functions


Functions Supported Items

Crossconnect Terminal Point On-Board E1 Up to 16 per MC-AV


(E1 Channel)
On-Board MODEM Up to 152 per MODEM

16E1-A Up to16 per card, up to 64 per IDU

STM1-A Up to 63 per card, up to 189 per IDU

MODEM-EA/EV up to 152 per card, up to 760 per IDU

MODEM-AV Up to 152 per card, up to 304 per IDU

MSE-A Up to 64 per card, and 64 per IDU

Crossconnect Terminal Point On-Board MODEM Up to 2 per MODEM


(STM-1 Channel)
STM1-A Up to 2 per card, up to 6 per IDU

MODEM-EA/EV Up to 2 per card, up to 10 per IDU

MODEM-AV Up to 2 per card, up to 4 per IDU

Crossconnect Capacity E1 Channel 2-Way Up to 388 per IDU


(5 × MODEM-152CH + 1 × E1-16CH)  2

iPASOLINK VR 4: SPECIFICATIONS GGS-000396-07E

2017-12-06 Gobierno San Juan © NEC Corporation 2015-2017


2-6 SPECIFICATION

2.2.3 ETH Functions

Functions Supported Items

VLAN VLAN ID Up to 4094 per IDU

C-Bridge Instance Up to 16 per IDU

Customer Bridge (in C-


Up to 15 per C-Bridge Instance
Bridge Instance)

VLAN Swap Up to 256 per IDU

FDB All Entries


Up to 32K per IDU
(Dynamic + Static)

Static Entries Up to 256 per IDU

Filter Ingress Filter Up to 16 per IDU

Egress Filter Up to 16 per IDU

Filter Rules (L2/L3) Up to 512 per IDU

QoS (VLAN Based) VLAN Group Up to 8 per IDU

Up to 4095 VLANs per VLAN Group

Priority Shaper Up to 8 per IDU

Mapping Table Up to 16 per IDU

QoS (Port Based) Classification Profile Up to 16 per IDU

Policer Policer Instance Up to 256 per IDU

Policer Rate Profiler Up to 64 per IDU

ETH OAM MEG Instances Up to 128 per IDU

MEP Instances Up to 128 per IDU

Peer MEP Up to 32 per IDU

Ethernet Ring Ring Index Up to 16 per IDU

RSTP/MSTP MSTI Up to 4 per Instances

Link Aggregation LAG Member Up to 8 per LAG

LAG Instance Up to 8 per IDU

GGS-000396-07E : SPECIFICATIONS

2017-12-06 Gobierno San Juan © NEC Corporation 2015-2017


SPECIFICATION 2-7

2.2.4 MPLS-TP
Functions Supported Items

E2E (End-to-End) Path Channel PW Up to 128 per IDU

Path LSP Up to 2048 per IDU

XC Up to 1024 per IDU

Linear Protection E2E LSP Up to 128 per IDU

MPLS-TP OAM MEG Up to 128 per IDU


[G.8113.1]
MEP LSP MEP Up to 128 per IDU

Peer MEP Up to 128 per IDU

MIP Up to 64 per IDU

2.2.5 Management Plane


Functions Supported Items

Inband Management VLAN Inband Interface Up to 4 per IDU

NMS Management VLAN NMS Port Up to 4 per IDU

Software Bridge Software Bridge ID Up to 8 per IDU

User Account User Account Up to 100 per IDU

ARP ARP Cache Up to 1024 per IDU

Static ARP Up to 256 per IDU

Routing Static Route Up to 128 per IDU

NTP NTP Server Up to 4 per IDU

DHCP DHCP Server Up to 3 per IDU

DHCP Relay Up to 4 per IDU

SNMP SNMP Community Up to 10 IDU

SNMP Trap Up to 3 per IDU

RADIUS RADIUS Server Up to 3 per IDU

iPASOLINK VR 4: SPECIFICATIONS GGS-000396-07E

2017-12-06 Gobierno San Juan © NEC Corporation 2015-2017


2-8 SPECIFICATION

2.2.6 Synchronization
Functions Supported Items

Timing Source Up to 3 per IDU

PTP Port Entry Up to 22 Physical Ports per IDU★


BC [1588v2/G.8275.1]
SOOC [G.8265.1] Master Entry Up to 5 Physical Ports per IDU★

★: The maximum number of the ports differs depending on the specified PTP Message Rate value.
Contact NEC for the further information.

2.2.7 Performance Monitor and Logs


Functions Supported Items

Log History Log Command, Event, Alarm


Up to 8,000 items per system

PM 15-Min History (Instance)

1-Day History (Instance)

VLAN Counter Up to 256 per IDU

LSP Counter Up to 256 per IDU

GGS-000396-07E : SPECIFICATIONS

2017-12-06 Gobierno San Juan © NEC Corporation 2015-2017


SPECIFICATION 2-9

2.3 Traffic Interface Specifications and Standards

2.3.1 STM-1
ITEM SPECIFICATIONS

Nominal Bit Rate 155.520 Mbit/s

Application Code [ITU-T G.957] S-1.1 L-1.1 CWDM

Transmitter at Reference Point S

Operating Wavelength Range 1261 to 1360 nm 1263 to 1360 nm 1471 to 1611 nm

Maximum Mean Launched Power –8 dBm 0 dBm 5 dBm

Minimum Mean Launched Power –15 dBm –5 dBm 0 dBm

Minimum Extinction Ratio (dB) 8.2 dB or more 10 dB or more 10 dB or more

Receiver at Reference Point R

Operating Wavelength Range 1261 to 1360 nm 1263 to 1360 nm 1260 to 1620 nm

Maximum Mean Launched Power –8 dBm –10 dBm –3 dBm

Minimum Mean Launched Power –28 dBm –34 dBm –34 dBm

Others

Type of Fiber Cable SMF

Connector LC Connector using SFP

iPASOLINK VR 4: SPECIFICATIONS GGS-000396-07E

2017-12-06 Gobierno San Juan © NEC Corporation 2015-2017


2-10 SPECIFICATION

2.3.2 1000BASE-X
ITEM SPECIFICATIONS

Application IEEE802.3 Full Duplex

1000BASE-SX 1000BASE-LX CWDM

Nominal Bit Rate 1250 Mbit/s

Coding Method 8B/10B

Transmitter at Reference Point S

Operating Wavelength Range 770 to 860 nm 1270 to 1355 nm 1471 to 1611 nm

SMSR 0.85 dB (RMS) 4 dB (RMS) 5 dB

Maximum Mean Launched Power 0 dBm –3 dBm 5 dBm

Minimum Mean Launched Power –9.5 dBm –11 dBm 0 dBm

Minimum Extinction Ratio (dB) 9 dB or more 9 dB or more 9 dB or more

Receiver at Reference Point R

Operating Wavelength Range 770 to 860 nm 1270 to 1355 nm 1260 to 1620 nm

Maximum Mean Launched Power –0 dBm –3 dBm –3 dBm

Minimum Mean Launched Power –17 dBm –19 dBm –22 dBm

Others

Target Distance 550 m 5 km 40 km or longer

Type of Fiber Cable MMF: GI Cable


SMF: Core/Clad (dia.: 9/125 µm)
(Core/Clad dia.: 50/125 µm)

Connector LC Connector using SFP

GGS-000396-07E : SPECIFICATIONS

2017-12-06 Gobierno San Juan © NEC Corporation 2015-2017


SPECIFICATION 2-11

2.3.3 10GBASE-R

ITEM SPECIFICATIONS

Application IEEE802.3 Full Duplex

10GBASE-SR 10GBASE-LR 10GBASE-ER

Nominal Bit Rate 10.3125 Gbit/s

Coding Method 64B/66B

Transmitter at Reference Point S

Operating Wavelength Range 840 to 860 nm 1260 to 1355 nm 1530 to 1565 nm

SMSR —— 30 dB 30 dB

Maximum Mean Launched Power –2.8 dBm 0.5 dBm 4.0 dBm

Minimum Mean Launched Power –7.3 dBm –8.2 dBm –4.7 dBm

Minimum Extinction Ratio (dB) 3.0 dB 3.5 dB or more 3.0 dB

Receiver at Reference Point R

Operating Wavelength Range 840 to 860 nm 1260 to 1355 nm 1530 to 1565 nm

Maximum Mean Launched Power –1.0 dBm 0.5 dBm –1.0 dBm

Minimum Mean Launched Power –9.9 dBm –14.4 dBm –15.8 dBm

Others

Target Distance 300 m 10 km 40 km

Type of Fiber Cable MMF: SI Cable, Core/ SMF: Core/Clad SMF: Core/Clad
Clad (dia.: 9/125 µm) (dia. 9/125 µm) (dia. 9/125 µm)

Connector LC Connector using SFP+

iPASOLINK VR 4: SPECIFICATIONS GGS-000396-07E

2017-12-06 Gobierno San Juan © NEC Corporation 2015-2017


2-12/END SPECIFICATION

This page is intentionally left blank.

GGS-000396-07E iPASOLINK VR 4: SPECIFICATIONS

2017-12-06 Gobierno San Juan © NEC Corporation 2015-2017


SYSTEM PERFORMANCES 3-1

3. SYSTEM PERFORMANCES

3.1 Power Consumption and Size

3.1.1 IDU/MDP

Ref. POWER DIMENSIONS


OBJECT WEIGHT DESCRIPTION
# CONSUMPTION [W × H × D] mm

IDU 115 W 5.0 kg Fully installed (approx.)


1 483 × 44 × 230
——— 2.6 kg Chassis (vacant slots)

3.1.2 Fundamental Cards

Ref. POWER DIMENSIONS


OBJECT WEIGHT DESCRIPTION
# CONSUMPTION [W × H × D] mm

MC-AV Main Card with Two On-Board


2-1 53 W★ 300 × 22 × 220 0.7 kg
MODEMs; Class 1 Laser Product

Main Card with One On-Board


2-2 40 W★ 300 × 22 × 220 0.7 kg
MODEM; Class 1 Laser Product

Main Card with No MODEM;


2-3 27 W★ 300 × 22 × 220 0.7 kg
Class 1 Laser Product

CLK-CV 001 Installed on MC-AV; External


3-1 3W 65 × 22 × 80 0.1 kg
Clock IN/OUT, 1588v2 BC/COOC

CLK-CV 002 Installed on MC-AV; External


3-2 1W 65 × 22 × 80 0.1 kg
Clock IN/OUT,

FAN-CV Colling Fan


4-1 5W 30 × 66 × 220 0.6 kg
(Type 001)

FAN-CV High-Powered Colling Fan (for


4-2 20 W 30 × 66 × 220 0.6 kg
(Type 002) Using MODEM-AV)

★: The value does not include that of SFP/SFP+ modules.

iPASOLINK VR 4: SPECIFICATIONS GGS-000396-07E

2017-12-06 Gobierno San Juan © NEC Corporation 2015-2017


3-2 SYSTEM PERFORMANCES

3.1.3 Cards for Universal Slots

Ref. POWER DIMENSIONS


OBJECT WEIGHT DESCRIPTION
# CONSUMPTION [W × H × D] mm

5-1 MODEM-EA 14 W 100 × 22 × 220 0.4 kg ODU Interface

5-2 MODEM-EV 15 W 100 × 22 × 220 0.4 kg ODU Interface

5-3 MODEM-AV 35 W 100 × 22 × 220 0.5 kg ODU Interface

6 16E1-A 8W 100 × 22 × 220 0.4 kg 16 × E1 Interface

STM1-A STM-1 Interface; Class 1 Laser


7 8 W★ 100 × 22 × 220 0.4 kg
Product

GbE-A 4×GbE [2×SFP + 2×RJ45];


8-1 8 W★ 100 × 22 × 220 0.4 kg
Class 1 Product

8-2 GbE4e-AV 8W 100 × 22 × 220 0.4 kg 4 × GbE [4 × RJ45]

8-3 GbE4f-AV 8 W★ 100 × 22 × 220 0.4 kg 4 × XGbE [SFP]; Class 1 Product

9 MSE-A 10 W 100 × 22 × 220 0.4 kg Multi Service Engine for PWE

10 AUX-A 3W 100 × 22 × 220 0.4 kg Auxiliary Input/Output Interface

11 SFP+ 5W 14 × 10 × 57 0.015 kg On 10GbE Ports

12 SFP 1W 14 × 10 × 57 0.015 kg On STM-1 Ports, GbE Ports

13 CWDMFA 0W 100 × 22 × 210 0.4 kg Class 1/1M Laser Product

14 CWDMFB 0W 100 × 22 × 210 0.4 kg Class 1/1M Laser Product

CWDMF CWDM supporting frame


15 —— 433 × 32 × 200 1.2 kg
Box Mount

★: The value does not include that of SFP/SFP+ modules.

GGS-000396-07E iPASOLINK VR 4: SPECIFICATIONS

2017-12-06 Gobierno San Juan © NEC Corporation 2015-2017


SYSTEM PERFORMANCES 3-3

3.2 Environmental Conditions

3.2.1 Temperature

Condition Requirements

Operating –5 to +50°C
Reference: –5 to+45°C by ETSI EN 300 019-1-3
Class 3.1E in the EU market

Transportation –40 to +70°C (ETSI EN 300 019-1-2 Class 2.3)

Storage –25 to +55°C (ETSI EN 300 019-1-1 Class 1.2)

3.2.2 Humidity

Condition Requirements

Operating Up to 95% (at +50°C, no condensing)


Reference: ETSI EN 300 019-1-3 Class 3.1E in the
EU market

Transportation ETSI EN 300 019-1-2 Class 2.3

Storage ETSI EN 300 019-1-1 Class 1.2

iPASOLINK VR 4: SPECIFICATIONS GGS-000396-07E

2017-12-06 Gobierno San Juan © NEC Corporation 2015-2017


3-4 SYSTEM PERFORMANCES

3.3 Power Line Requirements

3.3.1 Input Voltage and Connector

Condition Requirements

Input Voltage Range –48 V DC (–40.5 to –57 V DC)


ETSI EN 300 132-2

Connector 4-Pin, 3.81 mm Pitch [1-178288-4]

3.3.2 Rated Current

Rated current is indicated on the equipment label:

here

The rated current for iPASOLINK VR 4, which previously was 8 Amperes, has been
changed to 12 Amperes since July 2016 due to newly added systems and functions.

GGS-000396-07E iPASOLINK VR 4: SPECIFICATIONS

2017-12-06 Gobierno San Juan © NEC Corporation 2015-2017


SYSTEM PERFORMANCES 3-5

3.4 Others

Category Standards Conforming to:

Spectrum ETSI EN 302 217-2

EMC ETSI EN 301 489-1, ETSI EN 301 489-4

Safety EN 60950-1, EN 60950-22

EMF EN 50385

For details, please visit our DoC:


http://www.nec.com/en/global/prod/nw/pasolink/support/RED_DoC.html

iPASOLINK VR 4: SPECIFICATIONS GGS-000396-07E

2017-12-06 Gobierno San Juan © NEC Corporation 2015-2017


3-6/END SYSTEM PERFORMANCES

This page is intentionally left blank.

GGS-000396-07E iPASOLINK VR 4: SPECIFICATIONS

2017-12-06 Gobierno San Juan © NEC Corporation 2015-2017

You might also like