You are on page 1of 2

PAW GmbH & Co.

KG
phone: +49-5151-9856-0, fax: +49-5151-9856-98

Solar water heating system Solex – LF for low flow systems

Solar/Primary circuit
The compact and completely preassambled solar water
heating system Solex for high flow systems is completely
insulated. It is equipped with a generously dimensioned
double-column heat exchanger, a prewired and preset con-
troller. All those advantages allow for a simple and quick
assembly as well as for secure commissioning.

Your advantages:

All connections 3/4’’ female

With pre-assembled steel wall brackt


can be mounted easily onto the wall

Fully assembled with flat sealing union connections

Full port ball valves

Flow check valve inside the solar circuit and


inside the secondary circuit, manual opener, inside
the solar circuit with 400 mm WC, especially for solar
systems, secondary with 200 mm WC, prevent any gravity
circulations

Solar circuit with large ball valve handles


easy handling, visible closing position, with integrated
full metal thermometer 0-160 °C, can be pulled off, with
thermowell integrated inside the ball valve, ball valves inside
the secondary circuit key-actuated

With solar circulation pumps by WILO


pre-assembled and prewired; aligned to the performance
of the water heating system, pumps are completely isola-
table- no draining necessary during pump service

Primary side with flow meter


for electronic measurement of the flow rate and heat
measurement.
Secondary circuit Secondary circuit
Integrated flushing and filling unit flow return
two drain valves (on the elbow unions on the heat ex-
changer) permit filling and flushing the primary circuit as
well as only the heat exchanger. On the secondary side with
deculator on the topmost point on the heat exchanger and
drain valve for the emptying of the heat exchanger.

accessories
see page
146-149

basic conditions: global radiation = 800 W/m²; efficiency h 0,05 = 0,625


Solex

For systems in high flow mode [15 l/(m2solar panels x h)]

Heat exchanger type 2P


with 21 plates operational mode surface of solar panels performance
15 l/(m2*h) 30 m2 15 kW

Heat exchanger type 2P


mit 45 plates operational mode surface of solar panels performance
04/2007

15 l/(m2*h) 50 m2 25 kW

116
PAW GmbH & Co. KG
phone: +49-5151-9856-0, fax: +49-5151-9856-98

Solar water heating system Solex – LF for low flow systems

Solar safety assembly


pressure relief valve 6 bar, high-temperature manometer 0-6 bar with valve,
flat sealing connection for expansion tank secondary side with 3 bar
pressure relief valve

Compact function-optimised design insulation Hydraulic scheme


with 2 storages
made of durable elastic EPP; 100% insulation of the fittings – minimised
heat loss

Highly efficient stainless steel heat exchanger


two sizes for small and larger installations, designed for low flow operation.
Generously dimensioned, for transmitting high performances with low tem-
perature differences, completely integrated into the insulation.

Integrated solar controller


completely pre-assembled, preset and prewired, assures quick assembly – only
the sensors for the storage tank and for the solar panels have to be assem-
bled and branched. The preset control system permmits a simple and clean
commissioning. The temperature-depending speed control of the primary and
secondary pump ensures the optimum use of the energy gained.

Integrated 3-way reversing valve


permits the optimum stratification of the energy gained in two buffer storages
or a stratified storage.

TECHNICAL DATA Solex - LF


Dimension DN 20 - 3/4“
Material fittings brass
gaskets Klingersil / EPDM Hydraulic scheme
insulation EPP with stratified storage
check valves modified PPS
heat exchanger plates + sockes: 1.4400
solder: 99,99% copper
Techn. data max. pressure 10 bar
max. temperature 130 °C, temporarily 160 °C
Equipment check valves 400 mm WC primary
200 mm WC secondary
safety valve 6 bar, for thermal solar systems
3 bar, für for heating sytems
manometer 0 - 6 bar, resistant to high
temperatures
thermometers 0 - 160 °C inside the solar circuit
Measurements connections 3/4“ female
over-all width 660 mm
over-all height 880 mm

Pressure drop Solex LF primary circuit / pump characteristic curve Pressure drop Solex LF secondary circuit / pump characteristic curve

Pressure drop 21 plates Pressure drop 21 plates


heat exchanger
pressure [m WC]

heat exchanger
pressure [m WC]

Pressure drop 45 plates


pressure [kPa]

Pressure drop 45 plates


Solex
pressure [kPa]

heat exchanger
heat exchanger

Flow rate [l/h] Flow rate [l/h]

Heat exchanger Pump version SI Item no

Type 2P primary: Grundfos Solar 15 - 80; secondary: Grundfos UPS 15 - 40 6091821 GS


21 plates
04/2007

Type 2P primary: Grundfos Solar 15 - 80; secondary:Grundfos UPS 15 - 40 6091845 GS


45 plates

Accessories are storage items; dispatch usually 2 days after order processing
117