THERMISTOR BAS I CS
H OM E / THERMISTO R BASICS
WHAT IS A THERMISTOR?
A thermistor is a resistance thermometer, or a resistor whose resistance is dependent on temperature.
The term is a combination of “thermal” and “resistor”. It is made of metallic oxides, pressed into a bead,
disk, or cylindrical shape and then encapsulated with an impermeable material such as epoxy or glass.
There are two types of thermistors: Negative Temperature Coefficient (NTC) and Positive Temperature Coefficient (PTC). With an NTC
thermistor, when the temperature increases, resistance decreases. Conversely, when temperature decreases, resistance increases. This
type of thermistor is used the most.
A PTC thermistor works a little differently. When temperature increases, the resistance increases, and when temperature decreases,
resistance decreases. This type of thermistor is generally used as a fuse.
Typically, a thermistor achieves high precision within a limited temperature range of about 50ºC around the target temperature. This
range is dependent on the base resistance.
CATEGORIES
The thermistor symbols are:
Laser Diode Drivers
QC Laser Drivers
Temperature Controllers
Accessories
The arrow by the T signifies that the resistance is variable based on temperature. The direction of the arrow or bar is not significant.
Thermistors are easy to use, inexpensive, sturdy, and respond predictably to changes in temperature. While they do not work well with
excessively hot or cold temperatures, they are the sensor of choice for applications that measure temperature at a desired base point.
They are ideal when very precise temperatures are required.
Some of the most common uses of thermistors are in digital thermometers, in cars to measure oil and coolant temperatures, and in
household appliances such as ovens and refrigerators, but they are also found in almost any application that requires heating or cooling
protection circuits for safe operation. For more sophisticated applications, such as laser stabilization detectors, optical blocks, and charge
coupled devices, the thermistor is built in. For example, a 10 kΩ thermistor is the standard that is built into laser packages.
Unlike other sensors, thermistors are nonlinear, meaning the points on a graph representing the relationship between resistance and
temperature will not form a straight line. The location of the line and how much it changes is determined by the construction of the
thermistor. A typical thermistor graph looks like this:
How the change in resistance is converted into measurable data will be covered in detail below.
Temp Range Within ˜50°C of a −260°C to +850°C −40°C to +100°C −20°C to +105°C
given center
temperature
Temperature Range: The approximate overall range of temperatures in which a sensor type can be used. Within a given temperature
range, some sensors work better than others.
Relative Cost: Relative cost as these sensors are compared to one another. For example, thermistors are inexpensive in relation to
RTDs, partly because the material of choice for RTDs is platinum.
Time Constant: Approximate time required to change from one temperature value to another. This is the time, in seconds, that a
thermistor takes to reach 63.2% of the temperature difference from the initial reading to the final one.
Stability: The ability of a controller to maintain a constant temperature based on the sensor’s temperature feedback.
For example, a bead thermistor is ideal for embedding into a device, while a rod, disk, or cylindrical head are best for optical surfaces. A
thermistor chip is normally mounted on a printed circuit board (PCB). There are many, many different shapes of thermistors and some
examples are:
Choose a shape that allows maximum surface contact with the device whose temperature is being monitored. Regardless of the type of
thermistor, the connection to the monitored device must be made using a highly thermally conductive paste or epoxy glue. It is usually
important that this paste or glue is not electrically conductive.
In the diagram below, illustrating an example system, there are three main components used to regulate the temperature of a device: the
temperature sensor, the temperature controller, and the Peltier device (labeled here as a TEC, or thermoelectric cooler). The sensor
head is attached to the cooling plate that needs to maintain a specific temperature to cool the device, and the wires are attached to the
temperature controller. The temperature controller is also electronically connected to the Peltier device, which heats and cools the target
device. The heatsink is attached to the Peltier device to help with heat dissipation.
The temperature controller is the brains of this operation. It takes the sensor information, compares it to what the unit to be cooled needs
(called the setpoint), and adjusts the current through the Peltier device to change the temperature to match the setpoint.
The location of the thermistor in the system affects both the stability and the accuracy of the control system. For best stability, the
thermistor needs to be placed as close to the thermoelectric or resistive heater as possible. For best accuracy, the thermistor needs to be
located close to the device requiring temperature control. Ideally, the thermistor is embedded in the device, but it can also be attached
using thermally conductive paste or glue. Even if a device is embedded, air gaps should be eliminated using thermal paste or glue.
The figure below shows two thermistors, one attached directly to the device and one remote, or distant from the device. If the sensor is
too far away from the device, thermal lag time significantly reduces the accuracy of the temperature measurement, while placing the
thermistor too far from the Peltier device reduces the stability.
In the following figure, the graph illustrates the difference in temperature readings taken by both thermistors. The thermistor attached to
the device reacted quickly to the change in thermal load and recorded accurate temperatures. The remote thermistor also reacted but not
quite as quickly. More importantly, the readings are off by a little more than half a degree. This difference can be very significant when
accurate temperatures are required.
Once the placement of the sensor has been chosen, then the rest of the system needs to be configured. This includes determining the
base thermistor resistance, the bias current for the sensor, and the setpoint temperature of the load on the temperature controller.
What are the maximum and minimum temperatures for the device?
Thermistors are ideal when measuring a single point temperature that is within 50°C of ambient. If the temperatures are excessively high
or low, a thermistor will not work. While there are exceptions, most thermistors work best in the range between -55°C and +114°C.
Since thermistors are nonlinear, meaning the temperature to resistance values plot on a graph as a curve rather than a straight line, very
high or very low temperatures do not get recorded correctly. For example, very small changes in very high temperatures will record
negligible resistance changes, which won’t translate into accurate voltage changes.
The table below shows the most effective temperature ranges for Wavelength thermistors at the two most common bias currents.
It is best to choose a thermistor where the setpoint temperature is in the middle of the range. The sensitivity of the thermistor is
dependent on the temperature. For example, a thermistor may be more sensitive at cooler temperatures than at warmer temperatures,
as is the case with Wavelength’s TCS10K5 10 kΩ thermistor. With the TCS10K5, the sensitivity is 162 mV per degree Celsius between
0°C and 1°C, and it is 43 mV / °C between 25°C and 26°C, and 14 mV °C between 49°C and 50°C.
What are the upper and lower voltage limits of the sensor input of the temperature controller?
The voltage limits of the sensor feedback to a temperature controller are specified by the manufacturer. The ideal is to select a thermistor
and bias current combination that produces a voltage inside the range allowed by the temperature controller.
Voltage is related to resistance by Ohm’s Law. This equation is used to determine what bias current is needed. Ohm’s Law states that the
current through a conductor between two points is directly proportional to the potential difference across the two points and, for this bias
current, is written as:
V = IBIAS x R
Where:
V is voltage, in Volts (V)
IBIAS is the current, in Amperes or Amps (A)
IBIAS means the current is fixed
R is resistance, in Ohms (Ω)
The controller produces a bias current to convert the thermistor resistance to a measurable voltage. The controller will only accept a
certain range of voltage. For example, if a controller range is 0 to 5 V, the thermistor voltage needs to be no lower than 0.25 V so that low
end electrical noise does not interfere with the reading, and not higher than 5 V in order to be read.
Assume the use of the above controller and a 100 kΩ thermistor, such as Wavelength’s TCS651, and the temperature the device needs
to maintain is 20°C. According to the TCS651 datasheet, the resistance is 126700 Ω at 20°C. To determine if the thermistor can work
with the controller, we need to know the usable range of bias currents. Using Ohm’s Law to solve for IBIAS, we know the following:
V / R = IBIAS
Yes, this thermistor will work, if the temperature controller bias current can be set between 2 µA and 39.5 µA.
When selecting a thermistor and bias current, it is best to choose one where the voltage developed is in the middle of the range. The
controller feedback input needs to be in voltage, which is derived from the thermistor resistance.
Since people relate to temperature most easily, the resistance often needs to be changed to temperature. The most accurate model used
to convert thermistor resistance to temperature is called the Steinhart-Hart equation.
Where:
T is temperature, in Kelvins (K, Kelvin = Celsius + 273.15)
R is resistance at T, in Ohms (Ω)
A, B, C, D, and E are the Steinhart-Hart coefficients that vary depending on the type of thermistor used and the range of temperature
being detected.
ln is Natural Log, or Log to the Napierian base 2.71828
The terms can go on infinitely but, because the error is so small, the equation is truncated after the cubed term and the squared term is
eliminated, so the standard Steinhart-Hart equation used is this:
One of the pleasures of computer programs is that equations that would have taken days, if not weeks, to solve are done in moments.
Type “Steinhart-Hart equation calculator” in any search engine and pages of links to online calculators are returned.
CONCLUSION
Thermistors are temperature-dependent resistors, changing resistance with changes in temperature. They are very sensitive and react to
very small changes in temperature. They are best used when a specific temperature needs to be maintained, and when monitoring
temperatures within 50°C of ambient.
Thermistors, as part of a temperature control system, are the best way to measure and control heating and cooling of a Peltier device.
Their ability to adjust in minute increments allows the greatest overall system stability. Thermistors can be embedded in or surface-
mounted on the device needing temperature monitoring. Depending on type, they can measure liquids, gases, or solids.
Wavelength supplies a variety of bead and cylindrical head thermistors. For a listing of the current selection, click here.
Wavelength uses cookies to provide increased site functionality, statistical analysis of usage and to locate errors. For more information, please read our
PRIVACY POLICY.
Copyright © 2008-2018 by Wavelength Electronics, Inc. - All Rights Reserved.
LinkedIn, the LinkedIn logo, the IN logo and InMail are registered trademarks or trademarks of LinkedIn Corporation and its affiliates in the United States and/or other countries.
LabVIEW is a registered trademark of National Instruments.