You are on page 1of 1

Cattle grid may be lowered to flush with the concrete walls

300 300
150 150

155

45
Ground Level

200

200
100

100
50

700

700
500

500
N10 at 200 mm intervals N10 at 200 mm intervals

400

400
Sl 81 or trench mesh Sl 81 or trench mesh
20 Mpa concrete

100
300 300

SECTION VIEW
Scale: 1:10

Cattle grid may be lowered to flush with the concrete walls

300

150

155
300 mm
Ground Level
200

100 mm
100

50

700
Length of the N10 bar is 600 mm
500

N10 at 200 mm intervals


400

Sl 81 or trench mesh
Width of the mesh is 600 mm and 20 Mpa concrete

provide 50mm cover at both ends

100
First excavate out the 700mm x 300 mm trench (area marked in light blue rectangle)and then excavate out the 300 mm x400 mm trench(area marked in dark blue rectangle) .
Then pour the concrete for the 300 mm x 400 mm trench with the N10 bar as shown in the drawing and for the 700mm x100 mm base with the trench mesh or SL 81 mesh in the middle as the first stage.
Finally, make formwork for the step shape wall and pour the concrete as the second stage. 300