ION-B Distributed Antenna System Training

ION-B Basics

• ION-B is an optical DAS capable of


transporting frequencies from 700
to 2700 MHz
• Single Mode Fiber optics enable:
– Wide bandwidth
– Linearity and transparency
– Best quality of any modulation format
– Long distance
– Minimum design and installation costs
– Flexibility for future evolution

• Modular approach enables scalable


investments

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
2
ION-B Main Components

• The modular master unit is located


with the BTS and connected via RF
interface. It can host various cards
including points of interface, RF to
optical converters, and passive
components

• RF signals are transported to the


remote unit over single mode fiber
at 1310nm. The mixed copper-fiber
cable can provide remote DC power
to the remote units over the copper

• The remote unit, which can be up to


3km away, has an optical to RF
converter, amplifier lineup,
duplexer, and one or two antenna
ports to be connected to the passive
coaxial cable network
ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
3
Master Unit: Main Technical Features
The Master Unit hosts 12 active auto-sensing slots (7TE x
4HE) for:
• Local Units-up to 8 TFLNs
• RF Interface and Combiner Modules
• Monitoring Interface Unit-TSUN4
• Extension Boards-Interconnect Links
The Master Unit (4HE)
• Modular system: for example 700 PS, LMR 800, 850 Cellular, LMR 900, 1900 PCS, 1700
AWS,700 LTE SISO,MIMO
• RF interface modules with integral attenuation/splitting/combining functions-TPOI
• Automatic Gain Control (AGC) on optical link
• Redundant power supply (option available)
• Serial/Ethernet ports for supervision interface –LMT/TSUN4
• Automatic Level Control (ALC) on uplink
The TPRN14 subrack modules: TSUN4, TPOIs, Splitters/Combiners, TFLN

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
4
Master Elements: TPRN Subrack

• 4HE (TPRNx) version


• 12 slots
• AC and DC versions
• Host any card in any slot
• Microcontroller and I2CBUS
integrated in the backplane to
process, buffer, and control the
alarms of all plug-in cards
• Integrated into AIMOS OMC

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
5
Master Elements: Subrack
Subracks are provided with:
• RS232 serial port to connect to the to a
laptop running LMT software
• RS485 ports which can work as input or
output towards a RS485 bus. Each
subrack in the bus has to be assigned a
unique binary address,connect via CAT5
cables
• Sub-D 15 poles male connector to
provide 4-opto-isolated input ports, a
summary of major and minor alarms, 2
relay ouput ports

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
6
Master Elements: TPOI- Point of Interface

• Active version
• Triple band
• Duplexed/Un-duplexed
inputs
• Separate adjustable
attenuation for each band,
uplink and downlink
• ALC protection

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
7
Master Elements:TPOI

• Attenuation can be set remotely


through LMT/Supervision system or
locally with the buttons
• 5 LEDs show status and alarm
informations

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
8
Master Elements:TPOI

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
9
Master Elements:TPOI

Downlink Insertion Loss 10 dB

Uplink Insertion Loss 0 dB

Maximum Input Power +33 dBm

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
10
Master Elements: MIMO TPOI7/7

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
11
Master Elements: MIMO TPOI7/7

• Attenuation can be set remotely


through LMT/Supervision system or
locally with the buttons
It is used to adjust the signal level at
the TFLN input
• In factory default insertion loss is 17
dB. It can be adjusted up to 0 dB
trough the LMT to cope with lower
eNodeB input signals
• 2 LEDs show status and alarm
informations

Used with the TFBM7/7 MIMO Booster

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
12
Master Elements: MIMO TPOI7/7

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
13
Master Elements: Optical Transceiver-TFLN
Aux. Port • Wideband 700 to 2700 MHz
• Enabled Board Auto-Sensing

UL RF • Supports up to 4 Remote Units


• Supports any ION-B Remote Unit

DL RF • Compact size: 4HE


• Auxiliary Channel for Future Expansion
• Comprehensive Diagnostics
Status LEDs • Alarm Supervision
• Low Power Consumption
Paired Optical • Maximum RF input: 10 dBm composite power
Connectors to –Typical Composite power requirement= 0 dBm
Remote Units per frequency band to achieve maximum remote
output power.

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
14
Master Elements: Optical Transceiver-TFLN

• 700 to 2700 MHz frequency range


• Wideband auxiliary channel
(700 to 2700 MHz)
• 3dB optical budget
• Separate UL and DL single mode
fibers
• Serving up to 4 remote units
• Status LEDs

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
15
Master Elements: Optical Transceiver-TFLN

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
16
Master Elements: Optical Transceiver-TFLN

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
17
Master Elements: TLCN2: 2-Way RF
Combiner/Splitter
The TLCN2 is a wideband 2-way RF combiner/splitter, designed to
distribute the signal coming from a donor BTS to the local units of
a BriteCell® system.

TLCN2 - 2-Way RF Combiner/Splitter

Frequency (MHz) 7001400 14002200 22002500

Impedance 50 Ohm

Insertion Loss 3.7 ± 0.4 dB 4.1 ± 0.5 dB 4.6 ± 0.4 dB

Return Loss > 16 dB > 15 dB > 14 dB

Isolation > 17 dB > 20 dB > 18 dB

Max RF Power +24dBm

Connector SMA-female

Cable Jumper Kit 4 jumpers Sucoform86, SMA-male

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
18
Master Elements: TLCN4: 4-Way RF
Combiner/Splitter
The TLCN4 is a wideband 4-way RF combiner/splitter, designed to
distribute the signal coming from a donor BTS to the local units of
a BriteCell® system.

TLCN4 - 4-Way RF Combiner/Splitter

Frequency (MHz) 7001400 14002200 22002500

Impedance 50 Ohm

Insertion Loss 7.4 ± 0.4 dB 8.0 ± 0.5 dB 8.4 ± 0.4 dB

Return Loss > 15 dB > 14 dB > 13

Isolation > 19 dB > 18 dB > 17 dB

Max RF Power +24 dBm

Connector SMA-female

Cable Jumpers Kit 8 jumpers Sucoform86, SMA-male

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
19
Master Elements: TLCN8-W: 8-Way
RF Combiner/Splitter

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
20
Master Elements Options: Interconnect Link
• The Interconnect Link allows to
group a cluster of remote
coverage systems at a common
BTS hotel providing consistent
advantages in terms of
management and maintenance
• Master/slave Interconnect Link
modules enable the connection
of two fully populated sub-racks
in a star configuration at a
distance of up to 20 km, 10dB
optical budget

I-Link
I-Link
I-Link
BTS Hotel

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
21
Master Elements Options: Interconnect Link

Master and Slave Interconnect Link Components

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
22
Master Elements Options: Interconnect
Link Key Features

• Multi-band
• One or two fibers bi-directional optical link for distances up to 20 km,
10 dB optical budget
• Virtual 0 dB loss link guaranteed by a 10 dB AGC range
• Direct connection to up to 8 TFLN master optical TRXs with integrated
8-way splitter/combiner
• Built-in modem for a complete alarm integration into ION-B standard
bus (10.7 MHz auxiliary channel)

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
23
Master Elements Options: Interconnect
Link System Performances

I-LINK Specifications ION-B Specifications with I-LINK

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
24
Master Elements Options: Remote Power
Supply

TRSN13-1, TRSN13-3 TRSN6-1


• 1 removable 600W AC/DC or DC/DC power • 1 removable 900W AC/DC power supply
supply • 6 non controlled twin outputs (2.5 A fuse)
• Optional 1 additional 600W AC/DC or DC/DC • Not integrated into supervision system
for redundancy or additional power
• 12 controlled outputs (2.5 A fuse, output
current measurement)
• 1 non controlled output (30 W maximum)
• Integrated into the supervision system
(possibility to remotely switch off RUs)

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
25
Master Elements Options: Remote Power
Supply
TRSN13-1 PS,12+1 OUT,600W,VAC TO -48,19"x1HE

TRSPM-1 AC/DC PS MODULE,600W

TRSN13-3 PS,12+1 OUT,600W,-48 TO -48,19"x1HE

TRSPM-3 DC/DC PS MODULE,600W

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
26
Master Elements Options: Remote
Supervision Unit-TSUN4

• AIMOS compatibility-SNMP
• System software for both ION-B and ION-M
systems
• ION-B device library updates via web interface
• Local and Remote Access via web browser
• Summary Alarm Contacts
• External In/Out Alarm Contacts
• Direct Access via Keyboard and Monitor
• Overall System Status Indicator

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
27
Master Elements: Maximum Design
Flexibility
TFAH-High Power Remote Unit

Local Unit - TFLN

TFAM-Medium Power Remote Unit

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
28
ION-B Remote Units

• Single and multi-band models


• Low, medium, and high power
versions
• Automatic Gain Control (AGC) for
optical loss compensation
• Blocking protection with UL
Automatic Level Control (ALC)
• Wideband auxiliary channel (700-
2700MHz) for system expansion
• Status LEDs and remote alarm
supervision

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
29
ION- B TFAM 85/19

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
30
Case B Remote Units

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
31
ION- B TFAM 85/19

ION- B TFAM 85/19

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
32
TFAH-US4B

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
33
TFAH-US4B

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
34
TFAH-US7B

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
35
TFAH-US7B

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
36
ION-B Extension Units

• SISO/MIMO system upgrades


• Medium power versions
• Power correction through Automatic
Level Control (ALC) at start-up
• 1 or 2 antenna ports (selectable
through external dip-switches)
• External alarm output to allow
monitoring through the remote unit

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
37
Extension Units: Product Portfolio

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
38
TFBM7-700 LTE SISO Extension Unit

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
39
Case B Extension Units

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
40
TFBM7-700 LTE SISO Extension Unit

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
41
TFBM7-700 LTE SISO Extension Unit

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
42
TFBM7/7-700 LTE MIMO Extension Unit

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
43
Case R2 Extension Units

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
44
TFBM7/7-700 LTE MIMO Extension Unit

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
45
TFBM7/7-700 LTE MIMO Extension Unit

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
46
TFBM7/7-700 LTE MIMO Extension Unit
Modules installed in TPRN14 Subrack

TFAM85/19 Coaxial Cable


Optical
TFLN2504 AUX
RF (UL/DL) CBC
Fiber
OPT DL
OPT 1
TPOI85/17/19 OPT UL
RF DL
OPT 2 AUX
850 MHz BTS Cellular
RF (UL/DL) CBC
OPT 3
RF DL RF UL
TFBM7/7
AWS
OPT 4
AUX
RF (UL/DL) 2-way
RF UL

1900 MHz BTS PCS TFLN2504

OPT 1 AUX
RF (UL/DL) 2-way
RF DL
OPT 2
TLCN2 TLCN4
OPT 3
RF UL
RF 1 RF 1
TPOI7/7
OPT 4
RF DL RF DL
RF 2

RF DL
RF 3 TFLN2504 Additional Remote Units
700 MHz BTS RF UL RF UL
700 #1
Path #1 OPT 1
RF 2 RF 4
RF UL
RF DL
700 MHz BTS OPT 2
700 #2
Path #2
OPT 3
RF UL

OPT 4

TFLN2504

OPT 1

RF DL
OPT 2
TFAM85/19 Coaxial Cable
OPT 3 Optical
RF UL
AUX
RF (UL/DL) CBC
Fiber
OPT DL
OPT 4
OPT UL
AUX
RF (UL/DL) CBC

TFBM7/7 MIMO Booster AUX


TFBM7/7
RF (UL/DL) 2-way

is used with the TPOI7/7


AUX
RF (UL/DL) 2-way

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
47
Remote Unit External Power Supply Adapter

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
48
Master Unit Installation Guidelines

• Design the system to meet the subrack power


requirement:
–75 watts for AC versions (TPRN14, TPRN24)
–100 watts for DC version (TPRN34)
• Use passive subrack (TPRN04) if it is needed to house
only passive equipment in order to optimize the system
cost
• Don’t house more than 8 TFLNs in one subrack
• Alternate active and passive cards as much as possible to
allow good air flow inside the subrack
• Leave 1HE free above and below subracks
ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
49
ION-B Component Power Requirements

• TFLN - 9 Watts
• TPOI – Dual Band-4 Watts. TriBand-6 Watts
• TSUN4 - 12 Watts
• TPOI7/7 - 20 Watts
• ILINK Master - 12 Watts
• ILINK Slave - 31 Watts

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
50
ION-B System Example

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
51
ION-B System Example
TPOI TPOI
TFLN TFLN TFLN TFLN TLCN4 TLCN2

AUX MAIN AUX MAIN AUX MAIN AUX MAIN


T T
R R
UL UL UL UL x x
UL DL UL DL DL DL
1 3 1 3 1 3 1 3

PCS1900E PCS1900E
C C UL R UL R
2 4 2 4 2 4 2 4 x x
DL DL DL DL
UL DL UL DL UL DL UL DL
RX TX RX TX RX TX RX TX T T
R R
x x
1 DL DL
-1- -1- -1- -1- AWS1700 AWS1700
UL R UL R
x x
2 1

-2- -2- -2- -2- T T


R R
x x
3 DL DL
CELL850 CELL850
UL R UL R
-3- -3- -3- -3- x x
4 2

-4- -4- -4- -4-

DL UL DL UL

A A

Attenuator

Attenuator

Attenuator
Attenuator

High Power High Power High Power High Power


Combiner Combiner Combiner Combiner

TX1/RX1 TX2/RX2 TX1/RX1 TX2/RX2 TX1/RX1 Tx2/Rx2 TX1/RX1 Tx2/Rx2

GSM 1990 BTS GSM 850 BTS UMTS 850 Node-B UMTS 1900 Node-B
(Duplexed) (Duplexed) (Duplexed) (Duplexed)

Point of Interface (BTS to TPOI)


ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
52
TFAH-US7B

Bands Supported
•Comm700 SISO
•LMR800
•Cellular850
•LMR900
•PCS1900
•AWS2100 SISO
•WiMAX

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
53
TPOI for TFAH-US7B

Note: WiMAX omitted

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
54
TFAH-US7B and TFBM7/7 (MIMO)

Bands Supported
•Comm700 MIMO
•LMR800
•Cellular850
•LMR900
•PCS1900
•AWS2100 SISO
•WiMAX

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
55
TPOI for TFAH-US7B and TFBM7/7

Note: WiMAX omitted

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
56
TFAH-US7B and TFBM7/70

Bands Supported
•Comm700 SISO
•PS700
•LMR800
•Cellular850
•LMR900
•PCS1900
•AWS2100 SISO
•WiMAX

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
57
TPOI for TFAH-US7B and TFBM7/70

Note: WiMAX omitted

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
58
TFAH-US7B and TFAH-US7/17

Path 1
Bands Supported
•Comm700 MIMO
•LMR800
•Cellular850
•LMR900
•PCS1900
•AWS2100 MIMO
•WiMAX

Path 2
ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
59
TPOI for TFAH-US7B and TFAH-US7/17

Note: WiMAX omitted

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
60
System Startup: Checks

Before turning up the system make sure that:


• Master unit has been configured and modules connected with RF jumpers
according to the design

• All TFLN fibers have been connected to the Remote Units

• All Remote power supplies haver been connected

• Each Remote Unit has been connected to the coverage antennas

• TSUN4 (if present) has been housed in the master unit TPRN subrack

• A unique address has been set for each TPRN subrack in the system
through the dip-switches on the backplane and subracks have been daisy
chained via RS485 bus CAT5 cables

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
61
System Startup

1. Switch on the Remote units


Initially both LEDs turns on. Red LED will switch off as soon as the TFLN is
turned on (DL optical power OK and no alarms) and only the green LED
remains on indicating proper power supply voltage
2. Switch on the Master unit
The TFLN initiates the discovery phase signalled by general alarm LED
blinking to identify and collect status information from the connected
Remote Units (if not check wether the Remote Unit discovery has been
disabled or is disconnected)
During the Discovery Process, RF system functionalities are not affected
3. Verify masking of unused TFLN optical ports (1,2,3,4 LEDs) and
unused TPRN slots via LMT / TSUN4 software in order to avoid
meaningless alarms, done automatically during Discovey Process
4. Check system alarm status via the LMT or TSUN4 software

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
62
Optical Link Characteristics

• Optical budget: 3dB typical

• Splice loss: 0.1dB typical

• Connector loss: 0.4dB typical

• Wide linear bandwidth

• Broadband laser noise (-138dBm/Hz)

• RF loss = 2 times optical loss


(1dB optical loss = 2 dB RF signal loss)

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
63
Localizing Fiber Faults

Fiber Testing:

• OTDR measurements need to be made with 8° connectors APC

• Optical Power measurements need to use APC connectors

• Non-angled (PC) and angled connectors (APC) cannot be


mated

• Fiber can be looped back at the remote with a fiber patch adapter.

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
64
ION-B System Fiber Installation Requirements

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
65
Alarm/Status Communication
ION-B BriteCell Plus LMT-Local Maintenance Terminal Software

LMT software is installed a PC and


is connected to the TPRN14
subrack RS232 port via a RS232
serial cable

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
66
Alarm/Status Communication
ION-B BriteCell Plus LMT

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
67
Alarm/Status Communication
ION-B BriteCell Plus LMT

Quick Configuration

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
68
Alarm/Status Communication
ION-B BriteCell Plus LMT

Advanced Configuration
ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
69
Alarm/Status Communication
ION-B BriteCell Plus TSUN 4

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
70
Comprehensive System Management:
Remote Connection via TCP/IP to TSUN4

Modem is
provisioned with
Static IP address
for remote access

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
71
Alarm/Status Communication
ION-B BriteCell Plus TSUN 4-Login- Local Connection

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
72
Alarm/Status Communication
ION-B BriteCell Plus TSUN 4-Login

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
73
Alarm/Status Communication-TSUN4

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
74
TSUN4 Status

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
75
ION-B System Component Discovery

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
76
ION-B System Inventory

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
77
TPRN Subrack Status

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
78
TPRN Subrack Parameters

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
79
TPRN Subrack Troubleshooting

• In case a degradation of the +12 Vdc power supply occurs (below an


in factory set threshold), TPRN is automatically switched to standby
mode to preserve system integrity (avoiding overcurrent issues on the
hosted boards)
• In case TPRN24 is used (redundant power supply) a degradation of
the +12 Vdc power supply results in an automatic switching from main
to spare converter. Only if also the spare power supply is degraded
the TPRN turns to standby mode
• Reboot is needed after the power supply functionalities are restored
• Each TPRN slot can automatically detect the active module presence.
If the module is detected but TPRN cannot communicate with it, an
I2CBus alarm is activated
• Turn off the TPRN subrack when installing and uninstalling modules

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
80
TPRN Subrack Alarms
TSUN Alarm Code description Alarm Description Active LED Supervision Priority Level Action Recommended Priority

Redundant supply active (only for


Backup power supply activated YELLOW MAJOR Return the unit MINOR
redundant power supply versions)

There is a degradation on the


Power Supply alarm power supply provided to the RED MAJOR Return the unit MAJOR
boards

Check if the fault is on the


Internal I2CBUS communication unit (see Supervision
I2CBUS bus error YELLOW CRITICAL MINOR
malfunction System). If not, return the
unit

Check ventilation and


Temperature alarm Over-temperature alarm YELLOW MINOR MINOR
environment

The device connected to the


Check the status of the
Aux input alarm nr0 input alarm port 0 caused an RED CRITICAL -
connected device
alarm condition

The device connected to the


Check the status of the
Aux input alarm nr1 input alarm port 1 caused an RED MAJOR -
connected device
alarm condition

The device connected to the


Check the status of the
Aux input alarm nr2 input alarm port 2 caused an RED MINOR -
connected device
alarm condition

The device connected to the


Check the status of the
Aux input alarm nr3 input alarm port 3 caused an RED WARNING -
connected device
alarm condition

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
81
TFLN Status

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
82
TFLN Parameters

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
83
TFLN Troubleshooting

If TFLN general alarm red LED (flash symbol ) is on:


• Replace the TFLN unit

If one of the TFLN 1,2,3,4 red LED is on:


• Check that the SC/APC optical connectors/adapters are clean
• Chech Remote Unit red LED. If it is on there is an issue with the
Remote Unit, troubleshoot it
• Check UL optical fiber.
Measure Pin and Pout on the UL fiber and compare with the expected
attenuation to see if any problem should have occured in the UL
optical link.
In case UL optical fiber attenuation is exceeding 4 dB, the system is
not able to compensate for the optical loss and the UL optical fiber
link needs to be repaired
ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
84
TFLN Alarms
Alarm Code Supervision Priority Priority
Alarm description Active LED Action Recommended
(TSUN description) Level Level

The optical power received on the


Check the ULx fiber and the
RXx optical power fail UL1 is too low and can’t no more be RED (LEDx) CRITICAL MAJOR
Remote Unit laser status
compensated

The optical power received is under


RXx AGC out of range the allowed 3dB optical loss but it can NONE MINOR Clean optical connectors MINOR
be compensated

Major Remote Unit 1 Alarm from RU1 RED (LED1) - Check Remote Unit status MAJOR

Major Remote Unit 2 Alarm from RU2 RED (LED2) - Check Remote Unit status MAJOR

Major Remote Unit 3 Alarm from RU3 RED (LED3) - Check Remote Unit status MAJOR

Major Remote Unit 4 Alarm from RU4 RED (LED4) - Check Remote Unit status MAJOR

DL laser alarm A fault occurs on the DL laser RED ( ) MAJOR Return the unit MAJOR

UL RF alarm HW failure on the UL RF section RED ( ) MAJOR Return the unit MAJOR

DL RF alarm HW failure on the DL RF section RED ( ) CRITICAL Return the unit MAJOR

Board failure alarm General failure on board RED ( ) MAJOR Return the unit MAJOR

Check ventilation and


Temperature alarm Over-temperature alarm NONE MINOR MINOR
environment

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
85
Active TPOI Status

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
86
Active TPOI Parameters

Verify the correct


RF output power
per design
documentation

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
87
Active TPOI Alarms
Alarm Code Supervision Priority Priority
Alarm description Active LED Action Recommended
(TSUN description) Level Level

Band 1 RF input power exceeds


RED
Over Power Band 1 the absolute maximum composite MAJOR Reduce input power MAJOR
(band 1)
input power

Band 2 RF input power exceeds


RED
Over Power Band 2 the absolute maximum composite MAJOR Reduce input power MAJOR
(band 2)
input power

Band 3 RF input power exceeds


RED
Over Power Band 3 the absolute maximum composite MAJOR Reduce input power MAJOR
(band 3)
input power

Band 1 RF output power exceeds


Overdrive/ALC Limiting Band 1 NONE MINOR Reduce input power MINOR
the defined Overdrive Threshold

Band 1 RF output power exceeds


Overdrive/ALC Limiting Band 2 NONE MINOR Reduce input power MINOR
the defined Overdrive Threshold

Band 1 RF output power exceeds


Overdrive/ALC Limiting Band 3 NONE MINOR Reduce input power MINOR
the defined Overdrive Threshold

RED
UL Band 1 alarm Uplink RF stage malfunctioning CRITICAL Return the unit MAJOR
(band 1)

RED
UL Band 2 alarm Uplink RF stage malfunctioning CRITICAL Return the unit MAJOR
(band 2)

RED
UL Band 3 alarm Uplink RF stage malfunctioning CRITICAL Return the unit MAJOR
(band 3)

Internal RF stage power supply


Vcc alarm RED (general) MJOR Return the unit MAJOR
malfunctioning

Check power supply provided


Power Supply alarm Subrack power supply failure RED (general) MAJOR by the subrack and in case MAJOR
replace it

Check ventilation and


Temperature alarm Over-temperature alarm NONE WARNING MINOR
environment

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
88
MIMO TPOI Alarms
Alarm Code Supervision Priority Priority
Alarm description Active LED Action Recommended
(TSUN description) Level Level

RF input power exceeds the absolute


Over Power RED MAJOR Reduce input power MAJOR
maximum composite input power

RF output power exceeds the


Overdrive/ALC Limiting NONE MINOR Reduce input power MINOR
defined Overdrive Threshold

Check RF cables. If ok, try


UL Ch.1 RF stage malfunctioning or
UL MIMO Ch.1 RF alarm RED CRITICAL rebooting the unit, if no changes MAJOR
synchronization missing
return the unit

Check RF cables. If ok, try


UL Ch.2 RF stage malfunctioning or
UL MIMO Ch.2 RF alarm RED CRITICAL rebooting the unit, if no changes MAJOR
synchronization missing
return the unit

Check RF cables. If ok, try


DL Ch.1 RF stage malfunctioning or
DL MIMO Ch.1 RF alarm RED CRITICAL rebooting the unit, if no changes MAJOR
synchronization missing
return the unit

Check RF cables. If ok, try


DL Ch.2 RF stage malfunctioning or
DL MIMO Ch.2 RF alarm RED CRITICAL rebooting the unit, if no changes MAJOR
synchronization missing
return the unit

Vcc alarm Internal power supply malfunctioning RED MJOR Return the unit MAJOR

Check power supply provided by


Power Supply alarm Subrack power supply failure RED MAJOR the subrack and in case replace MAJOR
it

Check ventilation and


Temperature alarm Over-temperature alarm NONE WARNING MINOR
environment

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
89
Remote Unit Status

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
90
Remote Unit Troubleshooting

If Remote Unit red LED is on:


• Check if any external equipment is connected to the Remote Unit and
it is working properly (see next slide)
• Check that the SC/APC optical connectors/adapters are clean
• Check DL optical fiber.
Measure Pin and Pout on the DL fiber and compare with the expected
attenuation to see if any problem have occured in the DL optical link.
In case DL optical fiber attenuation is exceeding 4 dB, the system is
not able to compensate for the optical loss and the DL optical fiber
link needs to be repaired
• Try swapping DL and UL fibers or Remote units to determine the
cause of the alarm.

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
91
Remote Unit Alarms
Active SUPERVISION ACTION PRIORITY LEVEL
ALARM CODE (TSUN) ALARM DESCRIPTION
LED PRIORITY LEVEL RECOMMENDED (subrack)

Antenna DC loop alarm ALWAYS OK

Check the DL fibre and


The optical power received on the DL is too
DL optical power fail1 RED MAJOR the TFLN laser MAJOR
low and can not be compensated
status

The optical power received is under the


AGC out of range1 allowed 3dB optical loss but it can be NONE WARNING Clean optical connectors MINOR
compensated

DL RF alarm
in Band x HW failure on the DL low band RF section RED CRITICAL Return the unit MAJOR
(one for each RU band)

Check the master unit


WiMax Synchronization Lost
The synch signal is not present RED MAJOR synch signal. If it is MAJOR
alarm
ok return the unit

Alarm on the device connected to alarm- Check external device


External 1 alarm RED MAJOR MAJOR
contact 1 or alarm connection

Alarm on the device connected to alarm- Check external device


External 2 alarm RED MAJOR MAJOR
contact 2 or alarm connection

Check external PSU. If it


UPS HW failure or malfunction.
Power supply alarm RED MAJOR works properly, MAJOR
RF is turned OFF
replace the unit

A malfunctioning on the digital part involves


Internal BUS alarm RED CRITICAL Return the unit MAJOR
a fault in monitoring functionalities

An I2CBUS failure may result in a wrong


Sensor fail NONE MINOR Return the unit MINOR
temperature reading

Check ventilation and


Temperature alarm Over-temperature alarm NONE WARNING MINOR
environment

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
92
Extension Unit Alarms
ACTIVE PRIORITY LEVEL
ALARM CODE ALARM DESCRIPTION ACTION RECOMMENDED
LED (subrack)

DL ALC overpower Power has increased the ALC range RED Check the RF power MAJOR

Check master unit and the


Synchronism Fault Synchronism has been loosen RED fiber. If it works properly, MAJOR
replace the unit

PLL alarm PLL is not locked to the frequency RED Return the unit MAJOR

Check external PSU. If it


Power supply alarm UPS HW failure or malfunction. RED works properly, replace MAJOR
the unit

• External alarms of the Extension Units must be cabled to the external alarms
of the corresponding Remote Units
• If the red LED of the Extension Unit is switched on, the alarm is reported back
to the Remote Unit as External Alarm with no further details
• Check the Master Unit for Synchronization (TPOI7/7 & MIMO EU) and RF
power levels.
If they are ok, the unit needs to be sent back for repair

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
93
Alarm/Status History

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
94
ION-B Reference Documentation

• ION-B User’s Manual


• TSUN4 Software Manual
• LMT User’s Manual
• ION-B System Datasheet
• ION-B Remote Unit Datasheets
• TPOI User’s Manual
• TRSN Power Supply User’s Manual
• Project Design Close Out Package documentation

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
95
CommScope Technical Support

CommScope Wireless Solutions - Joliet, IL 60433


Customer Support Center
800-255-1479

CommScope Wireless Solutions


Distributed Coverage and Capacity Solutions
Technical Support - Garner, NC 27529
888-297-6433

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
96
Thank you!

ION-B TRAINING
PRIVATE AND CONFIDENTIAL
© 2012 CommScope, Inc
97

You might also like