The action of concentrated loads is on a smaller area in the structural members. In most cases, this reaction is the
one from the column acting against the slab. Eventually the slab will fail. One possible method of failure is that the
load punches through the slab.
Some examples of the occurrence of concentrated loads on a slab are a column, particularly on a pad foundation,
and wheel loads. This same type of failure could also happen in another way. Turning the structure upside down
we get a flat slab supported by a column, where there is a high concentration of shear force around the column
head.
When the total shear force exceeds the shear resistance of the slab, the slab will be pushed down around the
column, or this can be viewed as the column being punched through the slab.
Punching shear failure mechanism is observed in normal floor slabs, flat slabs, and in the foundation slabs below
the column. In pad foundations, where weight and depth are not so critical, it’s effects are satisfied by providing
sufficient depth.
https://theconstructor.org/structural-engg/punching-shear-slabs-foundations/17716/ 1/4
26/03/2018 What is Punching Shear? Punching Shear in Slabs and Foundations
Hence, there is a reduction of ultimate load capacity of the structure below the flexural capacity by the action of
shear. But when compared to beam shear, the punching shear is less critical.
In slabs, the punching shear occurs when they are subjected to high values of concentrated loads. These load
categories includes the wheel loads on the bridge slabs or the loads from above floors on the columns that support
the slab floors.
The Maximum Punching Shear Stress is determined based on the punching shear failure cone and the applied
values of shear and moments.
Fig.1. Punching Shear Failure Zone for Slabs above and below the column
The ‘d’ is the effective depth of the slab. The punching shear perimeter is formed at a distance of d/2 from the
edges of the column or the pedestal. In the figure-1, Dped is the depth of the pedestal.
1. Undergo proper checking to make sure that the concrete itself is strong enough.
2. If the concrete lacks adequate strength, check whether the amount of reinforcement that is provided is
reasonable.
https://theconstructor.org/structural-engg/punching-shear-slabs-foundations/17716/ 2/4
26/03/2018 What is Punching Shear? Punching Shear in Slabs and Foundations
Different failure zones are mentioned below in figure-2 based along with the area where the reinforcement have to
be provided. Usually vertical and traverse failure lines are possible. We do not actually know where the failure can
occur. So, each possible failure plane must be reinforced.
Based on building codes, the slabs are designed for punching shear as follows:
1. A cylindrical control surface is considered around the loaded area or the column area at a particular distance.
This distance is proportional to the slab depth. This is shown in figure-3.
https://theconstructor.org/structural-engg/punching-shear-slabs-foundations/17716/ 3/4
26/03/2018 What is Punching Shear? Punching Shear in Slabs and Foundations
2. The average shear stress on the control surface must not exceed the design strength. This design strength is
often proportional to the tensile strength.
The effects of moment transfer at the column or the slab junction is facilitated by the design for punching shear.
The punching shear assessment is based on different parameters. These parameters are sections at particular
distance from the face of the column.
Among different sections, the most important ones are at the face of the column and at a distance of d/2 on either
side of the column.
If the shear stress at these sections exceeds the allowable stress value, the structure will be subjected to punching
failure. The design formulas and parameter distance would vary from one code to other. But the concept behind
the assessment of punching shear failure is the same.