I-PASOLINK configuration and initial
setup
For iPasolink
1000
For iPasolink
400
For iPasolink
200
10/100 Base-TX
(RJ-45)
TOPC-E4011E-02- XXXXXX
LCT COMMUNICATION INTERFACE
THE LOCAL CRAFT TERMINAL IS USED TO SETUP, MONITOR AND MAINTAIN iPASOLINK RADIO. iPASOLINK
SUPPLY USER GUI ENVIRONMENT THROUGH WEB BROWSER. LCT SUPPORTS BOTH LOCAL AND REMOTE
CONNECTIONS
TOPC-E4011E-02- XXXXXX 3
LCT Startup and Login
4
WebLCT LOGOUT
Always Logout using this button before
disconnecting the cable.
5
WebLCT Initial Screen
Login User Name Summary Alarm Indication Opposite Site Links Maintenance Logout
Indicate the current Indicate the summary alarm of ODU, IDU, Connect to opposite Maintenance ON/OFF button Logout button
logged in user AUX I/O, TCN, & Maintenance Status station (s)
Block Diagram
Indicate the LCT Main Display detail alarm & status information
Menu of items selected from the Tabs
6
WebLCT Initial Screen
F/W Version Site (NE) Name and IP Address Opposite Site Links
Indicate the current Indicate Network element name and it’s Connect to opposite
Firm Ware Version IP address station (s)
7
NETWORK MANAGEMENT
8
GENERAL SETTING
Select General Setting from the Network
1 Management Configuration Menu. NE Primary IP
Setting is displayed
2
2 Click the Setup icon, General Setting
1 window opens.
9
GENERAL SETTING (DETAIL) 1 of 5
To change Network
parameters, Click the Setup
icon, General Setting
(Detail) window opens
10
GENERAL SETTING (DETAIL) 2 of 5
Item Parameter Description
NE2 Port Setting
NE2 Port IP x.x.x.x Input IP Address of NE2 port used
Address for serial back-back connection
NE2 Port Used Use NE2 port
Usage Not Used Not use NE2 port
NE2 Port 9600 specify the line speed of NE2 port2
Speed 19200
Ethernet Port Setting (NMS / NE1 Port)
Usage Used Use Ethernet port
Not Used Not use Ethernet port
Auto Enable enable the Auto Negotiation of
Negotiation Ethernet port
Disable Disable the Auto Negotiation of
Ethernet port
Discovery Used search of the network access
Usage Not Used machinery using Ethernet connection
NE Branch Setting
Branch 1 to 4 Select the Branch Number
Number Branches
Default x.x.x.x Input the Default Gateway
Gateway
Restrict LCT Connection
Item Parameter Description LCT Port Any Connection from Local/Remote to
Inband Management VLAN Setting Setting LCT Port
VLAN ID 1 to 4094 VLAN ID of Inband Management VLAN Only to only connection from Local to LCT
Inband management Used Use Inband management VLAN Local NE Port
VLAN usage Not Used Not use inband management function
IP Address x.x.x.x Enter IP address of inband management port
Subnet mask x.x.x.x enter subnet mask for inband management
11
GENERAL SETTING (DETAIL) 3 of 5
12
GENERAL SETTING (DETAIL) 4 of 5
When
When NE2
NE2 port
port is
is used
used for
for serial
serial connection
to other PASOLINK
to other PASOLINK configure this NE2 Port
Setting
Setting
Select
Select Inband
Inband Management
Management VLAN
VLAN Setting
Select
Select usage of
of NMS
NMS and
and NE1
NE1 ports
ports set
set the
the
port parameters accordingly
port parameters accordingly
LCT
LCT Port
Port Setting
Setting :: select
select “any”
“any” radio
radio button
button to
to connect
connect to
to remote
remote
NEs.
NEs. From
From the
the local
local LCT
LCT Port
Port
Select
Select “Only
“Only to
to Local
Local NE”
NE” radio
radio button
button to
to prevent
prevent connection
connection to
remote NE from local LCT port.
remote NE from local LCT port.
13
GENERAL SETTING (detail) 5 of 5
Select the number of branches the NE belongs to
14
ROUTING SETTING
15