You are on page 1of 40

EMS-BGF

Version 13

Windows
Installation Guide
4BGHT6-EMSW-249
EMS-BGF Installation Guide
V13
Catalog No: X35372
February 2011
1st Edition

© Copyright by ECI Telecom, 2002-2011. All rights reserved worldwide.


This is a legal agreement between you, the end user, and ECI Telecom Ltd. (“ECI Telecom”). BY OPENING THE
DOCUMENTATION AND/OR DISK PACKAGE, YOU ARE AGREEING TO BE BOUND BY THE TERMS OF THIS
AGREEMENT. IF YOU DO NOT AGREE TO THE TERMS OF THIS AGREEMENT, PROMPTLY RETURN THE
UNOPENED DOCUMENTATION AND/OR DISK PACKAGE AND THE ACCOMPANYING ITEMS (INCLUDING
WRITTEN MATERIALS AND BINDERS OR OTHER CONTAINERS), TO THE PLACE FROM WHICH YOU
OBTAINED THEM.
The information contained in the documentation and/or disk is proprietary and is subject to all relevant copyright,
patent, and other laws protecting intellectual property, as well as any specific agreement protecting ECI Telecom's
rights in the aforesaid information. Neither this document nor the information contained in the documentation and/or
disk may be published, reproduced, or disclosed to third parties, in whole or in part, without the express prior
written permission of ECI Telecom. In addition, any use of this document, the documentation and/or the disk, or the
information contained therein for any purposes other than those for which it was disclosed, is strictly forbidden.
ECI Telecom reserves the right, without prior notice or liability, to make changes in equipment design or
specifications. Information supplied by ECI Telecom is believed to be accurate and reliable. However, no
responsibility whatsoever is assumed by ECI Telecom for the use thereof, nor for the rights of third parties, which
may be affected in any way by the use and/or dissemination thereof.
Any representation(s) in the documentation and/or disk concerning performance of ECI Telecom product(s) are for
informational purposes only and are not warranties of product performance or otherwise, either express or implied.
ECI Telecom's standard limited warranty, stated in its sales contract or order confirmation form, is the only warranty
offered by ECI Telecom.
The documentation and/or disk is provided “AS IS” and may contain flaws, omissions, or typesetting errors. No
warranty is granted nor liability assumed in relation thereto, unless specifically undertaken in ECI Telecom's sales
contract or order confirmation. Information contained in the documentation and in the disk is periodically updated,
and changes will be incorporated in subsequent editions. If you have encountered an error, please notify ECI
Telecom. All specifications are subject to change without prior notice.
The documentation and/or disk and all information contained therein is owned by ECI Telecom and is protected by
all relevant copyright, patent, and other applicable laws and international treaty provisions. Therefore, you must
treat the information contained in the documentation and disk as any other copyrighted material (for example, a
book or musical recording).
Other Restrictions. You may not rent, lease, sell, or otherwise dispose of the documentation and disk, as
applicable. YOU MAY NOT USE, COPY, MODIFY, OR TRANSFER THE DOCUMENTATION AND/OR DISK OR
ANY COPY IN WHOLE OR PART, EXCEPT AS EXPRESSLY PROVIDED IN THIS LICENSE. ALL RIGHTS NOT
EXPRESSLY GRANTED ARE RESERVED BY ECI Telecom.
All trademarks mentioned herein are the property of their respective holders.
ECI Telecom shall not be liable to you or to any other party for any loss or damage whatsoever or howsoever
caused, arising directly or indirectly in connection with this documentation and/or disk, the information contained
therein, its use, or otherwise. Notwithstanding the generality of the aforementioned, you expressly waive any claim
and/or demand regarding liability for indirect, special, incidental, or consequential loss or damage which may arise
in respect of the documentation and/or disk and/or the information contained therein, howsoever caused, even if
advised of the possibility of such damages.
The end user hereby undertakes and acknowledges that they read the "Before You Start/Safety Guidelines"
instructions and that such instructions were understood by them.
It is hereby clarified that ECI Telecom shall not be liable to you or to any other party for any loss or damage
whatsoever or howsoever caused, arising directly or indirectly in connection with you fulfilling and/or failed to fulfill
in whole or in part the "Before You Start/Safety Guidelines" instructions.
Contents
About This Guide..................................................................... 1-1
Overview .......................................................................................................... 1-1
Intended Audience ........................................................................................... 1-1
What You Need to Know .................................................................................. 1-1
Document Conventions .................................................................................... 1-2
Related Documentation .................................................................................... 1-2
Obtaining Technical Documentation ................................................................ 1-3

Installing EMS-BGF on Windows ........................................... 2-1


Overview .......................................................................................................... 2-1
Installation Procedures ..................................................................................... 2-2
Starting EMS-BGF Components .................................................................... 2-29

GUI Cut Through (GCT) ........................................................... 3-1

4BGHT6-EMSW-249 ECI Telecom Ltd. Proprietary i


Contents EMS-BGF Installation Guide

ii ECI Telecom Ltd. Proprietary 4BGHT6-EMSW-249


1
About This Guide

In this chapter:
Overview ......................................................................................................... 1-1
Intended Audience ........................................................................................... 1-1
What You Need to Know ................................................................................ 1-1
Document Conventions ................................................................................... 1-2
Related Documentation ................................................................................... 1-2
Obtaining Technical Documentation ............................................................... 1-3

Overview
This guide describes the procedures for installing the EMS-BGF software on a
Windows operating system.

Intended Audience
This guide is intended for network operations personnel and system
administrators who are responsible for network element management.

What You Need to Know


This document assumes that the reader is familiar with the following:
 BG-9305 products
 Basic internetworking terminology and concepts
 Network topology and protocols
 Microsoft Windows 2003 Server and Windows XP /Vista
 Telecommunication Management Network (TMN) architecture model

4BGHT6-EMSW-249 ECI Telecom Ltd. Proprietary 1-1


About This Guide EMS-BGF Installation Guide

Document Conventions
When applicable, this manual uses the following conventions.
Convention Indicates Example
Bold Names of menus, commands, In the Alarms menu...
windows, dialog boxes, and
most GUI elements
Menu > Option Selection from a menu, or Select Update > View
leading to another command Objects
Borders around text Notes, cautions, and warnings See examples below

NOTE: Text set off in this manner presents clarifying


information, specific instructions, commentary, sidelights, or
interesting points of information.

CAUTION: Text set off in this manner indicates that failure


to follow directions could result in damage to equipment or
loss of information.

WARNING: Text set off in this manner indicates that failure


to follow directions could result in bodily harm or loss of life.

Related Documentation
The following publications may be of assistance to you regarding EMS-BGF
operations:
 General description documents of appropriate BroadGate products
 BroadGate Product Line System Specifications
 LightSoft Network Management System User Manual
 BroadGate EMS-BGF User Manual (CESR)
 BroadGate EMS-BGF User Manual (MSPP+Radio)
 BroadGate LCT-BGF User Manual

1-2 ECI Telecom Ltd. Proprietary 4BGHT6-EMSW-249


EMS-BGF Installation Guide About This Guide

Obtaining Technical
Documentation
To obtain technical documentation related to any ECI Telecom Ltd. product,
please contact:
ECI Telecom Ltd.
Network Solutions Division
Documentation Department
30 Hasivim St.
Petach Tikva 49130 - Israel
Fax: +972-3-9268060
mzilto:techdoc.feedback@ecitele.com
+972-3- 92660001-888- ECI-TECH (324- 8324)

+972-3- 92663701-954-351- 4406

mailto:on.support@ecitele.com

ECI's XDM and BroadGate product lines are


certified to comply with MEF9 and MEF14
standards.

4BGHT6-EMSW-249 ECI Telecom Ltd. Proprietary 1-3


About This Guide EMS-BGF Installation Guide

1-4 ECI Telecom Ltd. Proprietary 4BGHT6-EMSW-249


2
Installing EMS-BGF on
Windows

In this chapter:
Overview ......................................................................................................... 2-1
Installation Procedures .................................................................................... 2-2
Starting EMS-BGF Components ................................................................... 2-29

Overview
This section describes how to install EMS-BGF on a Windows operating
system.

4BGHT6-EMSW-249 ECI Telecom Ltd. Proprietary 2-1


Installing EMS-BGF on Windows EMS-BGF Installation Guide

Installation Procedures
You can begin the installation after confirming that the items described in
Hardware and Software Requirements are available. The installation must be
performed according to the procedures described in this section.

Installing the Windows Operating System


Before installing EMS-BGF software, the Windows operating system must be
installed on the NM computer. The EMS-BGF currently supports the following
Windows operating systems:
 Windows 2003 Server
 Windows XP Professional
 Windows Vista

To install the Windows operating system:


 Insert the Windows operating system installation CD-ROM in the CD
drive, and install the operating system in the NM computer's c:\winnt
directory.

NOTE: The hard disk is divided into two logic disks. Logic
disk D is used to install the MySQL software. Logic disk C is
used to install the Windows operating system files and other
application programs.
We do not provide operating systems as part of the
installation CDs package. The step described here is for
informational purposes only.

2-2 ECI Telecom Ltd. Proprietary 4BGHT6-EMSW-249


EMS-BGF Installation Guide Installing EMS-BGF on Windows

Installing Devices and Drivers, and


Configuring Parameters
Install the following equipment to support EMS-BGF installations:
 An Ethernet card. Install the network card driver program, and configure
network parameters, including the TCP/IP protocol, computer name, and
work team name. Set the computer name and work team name as a string
that represents the customer's information.
 Install the video card driver and configure it with a resolution of 1024 x
768 and a 32-bit color display.
 If the computer has an audio card, install and configure the corresponding
driver.

NOTE: We do not provide drivers for these cards. These


details are for informational purposes only.

Accessing the EMS-BGF Installation CD


Window
Follow the procedure below to open the EMS-BGF Installation CD window,
which is used to install various EMS-BGF network management system
components.

4BGHT6-EMSW-249 ECI Telecom Ltd. Proprietary 2-3


Installing EMS-BGF on Windows EMS-BGF Installation Guide

Installing Orbix
This section describes how to install Orbix.

To install Corbix:
1. In the EMS-BGF Installation CD window, select Install Orbix6.3.3 to
install the Orbix. The following window opens.

2. Wait a few minutes during the installation. When the installation is


completed, the following window opens.

2-4 ECI Telecom Ltd. Proprietary 4BGHT6-EMSW-249


EMS-BGF Installation Guide Installing EMS-BGF on Windows

3. Press any key to exit the window. The local notification service starts
automatically.
4. Go to the NMS server zone and log in as the user "root", then add a line of
EMS-BGF server IP and hostname to the file: /etc/hosts in this zone.

Installing MySQL 5.0


This section describes how to install MySQL 5.0, using the EMS-BGF
Installation CD-ROM.

NOTE: If MySQL software is already installed on the PC, it


must first be uninstalled and the old installation folders
should also be deleted. After uninstalling, you can install the
MySQL 5.0 using the supplied EMS-BGF installation CD.

To install MySQL 5.0:


1. In the EMS-BGF Installation CD window, select Install MySQL 5.0.
The Welcome window opens.

4BGHT6-EMSW-249 ECI Telecom Ltd. Proprietary 2-5


Installing EMS-BGF on Windows EMS-BGF Installation Guide

2. Click Next. The Setup Type window opens.

3. Select the Custom radio button and click Next. The Custom Setup
window opens.

2-6 ECI Telecom Ltd. Proprietary 4BGHT6-EMSW-249


EMS-BGF Installation Guide Installing EMS-BGF on Windows

4. Click the Change button and in the Change Current Destination Folder
window, it is recommended to locate the files in disk 'D:'. Click OK to
return to the Custom Setup window.

5. Click Next in the Custom Setup window. The Ready to Install the
Program window opens.

4BGHT6-EMSW-249 ECI Telecom Ltd. Proprietary 2-7


Installing EMS-BGF on Windows EMS-BGF Installation Guide

6. After checking the current settings, click Install. Progress bars are
displayed showing the progress of the operation.

7. When copying is complete, the MySQL.com Sign-Up window opens.

2-8 ECI Telecom Ltd. Proprietary 4BGHT6-EMSW-249


EMS-BGF Installation Guide Installing EMS-BGF on Windows

8. Select the Skip Sign-Up radio button and click Next. The Wizard
Completed window opens.

9. Ensure that the Configure the MySQL Server now checkbox is selected
and click Finish to configure the MySQL server, as described in the
following section.
The following section describes the procedure to configure the MySQL server.

4BGHT6-EMSW-249 ECI Telecom Ltd. Proprietary 2-9


Installing EMS-BGF on Windows EMS-BGF Installation Guide

To configure the MySQL server:


1. After completing the installation of the MySQL server, the Welcome
window for the MySQL Server Instance configuration opens. If you have
have installed MySQL server and want to reconfigure the MySQL server,
on your desktop, select Start > All Programs > MySQL > MySQL
Server 5.0 > MySQL Server Instance Config Wizard in the menu. The
following window opens.

2-10 ECI Telecom Ltd. Proprietary 4BGHT6-EMSW-249


EMS-BGF Installation Guide Installing EMS-BGF on Windows

2. Click Next to open the MySQL Server Instance Configuration window


where you can select a configuration type.

3. Select the Detailed Configuration radio button and click Next. The
following window opens.

4BGHT6-EMSW-249 ECI Telecom Ltd. Proprietary 2-11


Installing EMS-BGF on Windows EMS-BGF Installation Guide

4. Select the Dedicated MySQL Server Machine radio button and click
Next. The following window opens.

5. Select the Multifunctional Database radio button and click Next. The
following window opens.

2-12 ECI Telecom Ltd. Proprietary 4BGHT6-EMSW-249


EMS-BGF Installation Guide Installing EMS-BGF on Windows

6. Click Next in the above window to set the approximate number of


concurrent connections to the server in the following window.

7. Select the Manual Setting radio button and then select 1000 in the
Concurrent connections dropdown list. Click Next. The following
window opens.

4BGHT6-EMSW-249 ECI Telecom Ltd. Proprietary 2-13


Installing EMS-BGF on Windows EMS-BGF Installation Guide

8. Ensure that both the Enable TCP/IP Networking and Enable Strict Mode
checkboxes are selected, and keep the default port number in the Port
Number field. Click Next. The following window opens.

9. Select the Manual Selected Default Character Set / Collation radio


button and then select 'utf8' in the Character Set dropdown list. Click
Next. The following window opens.

2-14 ECI Telecom Ltd. Proprietary 4BGHT6-EMSW-249


EMS-BGF Installation Guide Installing EMS-BGF on Windows

10. Ensure that both the Install As Windows Service and Include Bin
Directory in Windows PATH checkboxes are selected and click Next.
The following window opens.

11. Ensure that the Modify Security Settings checkbox is selected and type
'eci_root' in both New root password and Confirm fields. Click Next. The
following window opens.

4BGHT6-EMSW-249 ECI Telecom Ltd. Proprietary 2-15


Installing EMS-BGF on Windows EMS-BGF Installation Guide

12. Click Execute to start the configuration. For some users, there may pop up
the following Connection Error window because of the security settings
in the computer.

Click Retry. If necessary, click Retry again. At the end of the process, the
following window opens.

13. Click Finish to complete the installation.

2-16 ECI Telecom Ltd. Proprietary 4BGHT6-EMSW-249


EMS-BGF Installation Guide Installing EMS-BGF on Windows

Installing the EMS-BGF Application


A tool called InstallAnywhere is provided to guide you through the installation
process of EMS-BGF.

To install the EMS-BGF application:


1. In the EMS-BGF Installation CD window, select Install EMS-BGF. The
Welcome window opens.

4BGHT6-EMSW-249 ECI Telecom Ltd. Proprietary 2-17


Installing EMS-BGF on Windows EMS-BGF Installation Guide

2. Click Next. The Setup Type window opens. Select EMS-BGF Server and
Client to install both the management service program and the client
program of the EMS-BGF.

If you select EMS-BGF Client, only the client program of the EMS-BGF
is installed.

2-18 ECI Telecom Ltd. Proprietary 4BGHT6-EMSW-249


EMS-BGF Installation Guide Installing EMS-BGF on Windows

3. Click Next. The Choose Destination Location window opens. Click


Change to choose the folder where you want to install the application. It is
recommended to install the application in 'D:\EMS-BGF' and it is not
allowed to have space in the name of the folder.

4. Click Next. The Ready to Install the Program window opens.

4BGHT6-EMSW-249 ECI Telecom Ltd. Proprietary 2-19


Installing EMS-BGF on Windows EMS-BGF Installation Guide

5. After reviewing the summary, click Install. The Installing EMS-BGF


window opens.

6. The installation application copies the program files required by the system.
When file copying is complete, The following window opens.

2-20 ECI Telecom Ltd. Proprietary 4BGHT6-EMSW-249


EMS-BGF Installation Guide Installing EMS-BGF on Windows

7. Click Finish. The installation application automatically starts the MySQL


System Configuration Wizard.
8. Close the Configing EMS-BGF window and restart the computer.

Configuring the System for MySQL


To configure the system for MySQL includes:
 Creating database required by the system
 Creating the system tables
 Configuring the services EMS-BGF requires

To configure the system for MySQL:


1. When the computer is restarted, select Start > All Programs > EMS-BGF
> Tools > System Config Wizard from the desktop. The System Config
Wizard for MySQL window opens, for configuring the MySQL database
and its tables and services.

4BGHT6-EMSW-249 ECI Telecom Ltd. Proprietary 2-21


Installing EMS-BGF on Windows EMS-BGF Installation Guide

2. Click Next. The following window opens.

Keep the default login information in the Connect to MySQL Server area,
including the server name, EMS DB name, port, user name and password.
With the correct connection, the configuration tool will create two
databases: LogDB and ConfigurationDB.

NOTE: The LogDB database is for storing alarm and


performance data; the ConfigurationDB database is for
storing NE configuration data.

2-22 ECI Telecom Ltd. Proprietary 4BGHT6-EMSW-249


EMS-BGF Installation Guide Installing EMS-BGF on Windows

3. If the LogDB and ConfigurationDB databases already exist, a window


opens, asking if you want to cancel and recreate. You can decide according
to the situation. Click Next in the above window. The following window
opens.

4.
5. If you want to configure as standalone mode, select the Configuration as
standalone mode radio button.

4BGHT6-EMSW-249 ECI Telecom Ltd. Proprietary 2-23


Installing EMS-BGF on Windows EMS-BGF Installation Guide

6. If you want to configure as integrated mode, select the Configuration as


integrated mode radio button, as shown below.

Input the parameters in the EMS NBI Parameters area as needed.

2-24 ECI Telecom Ltd. Proprietary 4BGHT6-EMSW-249


EMS-BGF Installation Guide Installing EMS-BGF on Windows

7. Click Next. The following window opens.

8. Click Finish to complete the installation.

4BGHT6-EMSW-249 ECI Telecom Ltd. Proprietary 2-25


Installing EMS-BGF on Windows EMS-BGF Installation Guide

Installing Remote Data Replicator Software


The EMS-BGF Remote Data Replicator (RDR) feature provides the database
backup for the EMS-BGF.

To install the EMS-BGF RDR:


1. In the EMS-BGF Standalone Installation CD window, select Install
RDR Server. The Introduction window opens.

2-26 ECI Telecom Ltd. Proprietary 4BGHT6-EMSW-249


EMS-BGF Installation Guide Installing EMS-BGF on Windows

2. Click Next. The Choose Install Folder window opens, as shown below.
Click Choose to choose the folder where you want to install the
application.

3. Click Next. The Pre-Installation Summary window opens.

4BGHT6-EMSW-249 ECI Telecom Ltd. Proprietary 2-27


Installing EMS-BGF on Windows EMS-BGF Installation Guide

4. After reviewing the summary, click Install. The Installing RDR Server
window opens. The installation application copies the program files
required by the system.

5. When file copying is complete, the Install Complete window


opens,showing the results of the installation.

6. Click Done to finish the installation of EMS-BGF RDR Server.

2-28 ECI Telecom Ltd. Proprietary 4BGHT6-EMSW-249


EMS-BGF Installation Guide Installing EMS-BGF on Windows

Starting EMS-BGF Components


During the installation procedures described in this manual, icons for running
the programs are automatically placed on the Windows desktop.
To start the EMS-BGF, do the following operations orderly:

 Start Server

 Start Client

NOTE: To have the access permission of rawrocket and to


ensure the NEPing function can be used, user who run the
EMS-BGF Server must be in the Administrator user group.

4BGHT6-EMSW-249 ECI Telecom Ltd. Proprietary 2-29


Installing EMS-BGF on Windows EMS-BGF Installation Guide

2-30 ECI Telecom Ltd. Proprietary 4BGHT6-EMSW-249


3
GUI Cut Through (GCT)
LightSoft manages a network through an EMS (Element Management System)
which provides LightSoft with the information it needs to maintain the
network. There are times when you may need to use LightSoft to view
windows from the EMS. Normally, this would require you to log into the EMS
on the local terminal and find the information manually. To make things easier
and more efficient, LightSoft’s GCT allows you to view EMS information
without having to start an individual EMS session.
To be integrated with Lightsoft, EMS-BGF server, EMS-BGF client and
LightSoft are installed on different non-global zones, as shown in the following
figure.

4BGHT6-EMSW-249 ECI Telecom Ltd. Proprietary 3-1


GUI Cut Through (GCT) EMS-BGF Installation Guide

From the figure, EMS-BGF client should be configured as Client-Server, and


provide GCT for several EMS-BGF servers.
If you install EMS-BGF on a PC with more than one network card, you must
configure the EMS-BGF to tell the NBI which IP you want to use:
1. Go to the EMS-BGF installation folder and find the file:
/etc/emsserver.properties.
2. Double-click to open the file and find the string:'RegisterIORHost =
127.0.0.1' in the NBI Main Configuration area.
3. Overwrite the the default IP: 127.0.0.1 with the desired IP.
4. Save the file.

3-2 ECI Telecom Ltd. Proprietary 4BGHT6-EMSW-249