You are on page 1of 48

CASTROL INDIA LTD.

BILL OF QUANTITIES FOR CIVIL & INTERIOR WORKS

Sr.No Description Unit Qty Rate Amount REMARKS

Civil & Interior Works


General Notes :-
All refurbishments door with 3 nos of hinges with
1 handle as per approval from client & Open door
closer of Ozone make.
All glazed partition with 100mm x 100mm plywood
2 boxing / solid wooden with laminate finish with
melamine polish glass beading .

A Reception & Reception Meeting Room


Demolitions Ceiling / Partition / Floor / Panelling /
1.1
Grid Ceiling

DEMOLITION OF EXISTING CEILING: Demolition


of Existing Ceiling / Partition / Floor / Panelling / Grid
Ceiling including all framework and sheet and
disposal of unserviceable material as directed to
municipal dumping ground. Rate should include
safety precaution/measures taken to other
Lighting /AC/ or any other related fixtures while
carrying out the activites.Complete with all respect
as per Architect Instructions.

Partition & Panelling Sqm 21.00 225 4,725


Ceiling Sqm 10.00 180 1,800
Grid Ceiling Sqm 11.00 180 1,980
Screeding Sqm 38.50 225 8,663

1.2 Screeding Sqm 38.50 425 16,363

CEMENT CONCRETE SCREEDING:-Providing and


laying cement concrete for flooring to a maximum
75mm TO 100mm thick using cement concrete 1:2:4
(1cement :2Coarse sand :4graded stone aggregate
20mm and down gauge) for flooring bands and other
similar locations, tamped, spaded, toweled and top
finished neat, smooth with floating coat of cement as
-
directed laid in alternate panels of area not more
than 2 sqm and laid to water levels or proper slopes
as directed with necessary shuttering, hacking the
existing surface, curing etc. specifications. Rate are
inclusive of Junction box frame work & installation.
Complete with all respect as per detail drawing &
Architect Instructions.

1.3 Water Proofing Works Below Screeding Sqm 39.00 150 5,850

WATERPROOFING WORKS :- Providing and


applying water proofing coats slurry into existing slab
. Providing, supplying, mixing and applying cement
coats with water proofing compound of sunanda /
Roff make flexible water-proofing slurry to a
-
thickness of 1mm over the bottom , including
preparation of surface, finishing, curing etc. all
complete at different levels as specified by the
Architect as per manufacturer's specifications and as
directed.

1.4 Ceiling Sqm 22.05 775 17,089

1 of 48
Sr.No Description Unit Qty Rate Amount REMARKS

Providing and fixing Gypsum False Ceiling of India


Gypsum / La gyp make which includes G.I.
Perimeter Channels of size 0.55 mm thick ( having
One Flange of 20 mm. and another flange of 30 mm
and a web of 27 mm ) along with perimeter of
ceiling, screw fixed to brick wall / partition with the
help of Nylon sleeves and screws at 610mm centres.
Then suspending G.I. intermediate channels of size
45mm (0.9mm thick with 2 flanges of 15 mm each)
-
from the soffit at 1220 mm centres with ceiling angle
of width 25 mm X 10 mm X 0.55 mm thick fixed to
soffit with G.I. cleat and steel expansion fasteners.
Ceiling section of 0.55mm thick having knurled web
of 51.5 mm and 2 flanges of 26 mm each with lips
of 10.5 mm are then fixed to the intermediate
channel with the help of connecting clips and in
direction perpendicular to the intermediate channel
at 450 mm centres.

12.5mm tapered edge Gypboard (conforming to IS


2095-1982) is then screw fixed to ceiling section with
25mm dry wall Philips screws at 230mm centres.
Screw fixing is done mechanically with drilling
machine with suitable attachment. Finally tapered
edges of the Gyp boards are to be jointed and
finished so as to have a flush look which includes
filling and finishing with jointing compound, paper -
tape etc complete as per the ASSESSMENT
practices of India Gypsum. Rate to be included all
kinds of profiles and cut outs required for light
fixtures, Speakers, Smoke detector, trap doors and
AC grill in the ceiling. The rate shall be inclusive of
Vertical Patties provided for fixing the gypsum ceiling
& also wherever height difference is there in ceiling.

Same as Above but in Cove light / Band up to 150


1.4A Rmt 18.00 250 4,500
mm
1.5 Modular Ceiling 0.5 NRC Sqm 16.20 950 15,390

GRID TILE CEILING: Providing & Fixing of


Armstrong Mineral Fibber Acoustical Suspended
Ceiling System with regular edge tiles should have
Humidity Resistance (RH) of 99%, NRC as mention
below, Light Reflectance >85%, Thermal
Conductivity k = 0.052- 0.057 w/m K, Colour White,
Fire Performance Class 0/Class1 (BS 476 Part 6&7)
in module size of 600 X 600 X 16 mm with Bio Block
coating on the face of the tile, suitable for Green
-
Building application, with Recycled content of
63%.The grid should be of “Armstrong” make with
silhouette with black groove - section flanges colour
white having rotary stitching on all T sections i.e. the
Main Runner, 1200 mm & 600 mm Cross Tees . The
T Sections have a Galvanizing of 120 grams per M2
& passed through 500 hrs of Salt test.The Tile & Grid
system used together should carry a 15 year
warrantee. Including Shadow line profile.

1.6 Reception Table Nos 1.00 70,000 70,000

2 of 48
Sr.No Description Unit Qty Rate Amount REMARKS

RECEPTION TABLE :-Providing and Fixing


Reception table as per approved design in the
drawing .finish with 6mm thick Glacia white colour
Corian with combination of veneer with melamine
polish on external side , 25 mm thick table top block
board finish in corian under structure to be finished
in approved veneer with 19mm thick block board. All
edges to be PVC finish as per the finish approved. -
All hardware's Hettich equivalent. Cost to include the
1 nos of pedestal as instructed in the drawing.Cost
to include all under structure and super structure
finish for all electrical,data ,services points and all
the items to complete the same. (Basic Rate for
Corian Rs. 650 per Sqft & veneer Rs. 70 Per Sqft .)

1.7 Reception Back Drop - Modifying Sqm 12.00 980 11,760


Providing & fixing Reception panelling refurbishment
with 4mm thk mdf skinning to receive graphics -
inclusing base coat of paint .
1.8 Repoilising of Existing Partition & Panelling Sqm 175.00 575 100,625
Removing & Appling 2 coats of melamine polish on
-
existing Veneer / Wooden surface
Same as above but for moulding grooves & steps up
1.8A Rmt 125.00 185 23,125
to 12mm to 150mm .
1.9 Partition -Gypsum Sqm 14.43 1,500 21,645

FULL HEIGHT PARTITION: Providing and fixing


frame of Full height 75mm thick partition with GI
Framework @ 600 mm c/c both ways (Fire retardant
and anti-termite treated) up to 2700 mm finish with
12 mm ply wood till 100 above false ceiling &
above , till true ceiling finished with both side one
-
layer of 12.5mm thk Gypsum board on either side
with glass wool insulation 50 mm thick glass wool
insulation of48 kg/ cum. density neatly packed in
tissue bags of various sizes and shapes, bags shall
be fully stitched all round with25 mm double leaf
fold, sealing the glass wool fibre fully.

The bags to be stuffed in the cavities of Gyp.


partitions from floor up to RCC slab above, cross
stitched from one side with GI frame work of partition
by 24 g GI wire to keep bags in position. UP
Twig/Rocklloyd make grade specified fixing to floor
& RCC roof with screw i/c provisions for grooves and
-
Fibber tape to be used for jointing and space/ cut-
outs for electrical sockets/switches and conduits etc.
as per detail drawings and specification and as
directed by Architect and duly fixed to floor/wall/RCC
roof with fasteners. Member placement to be worked
out as per grooves. complete as per drawing.

Note : - All vertical & Horizontal edges will be


covered 12mm MDF with paint finish . To receive
-
modular partition section & making pen tray cut outs
as directed by architects .
2.0 Glass Panelling Sqm 14.04 3,500 49,140

GLASS PANELLING :- Providing and fixing 6mm


thick Saint Gobin Planilaque white glass fixed with
3M double sided foam tapes on 9 plywood backing
with laminated strips as per instruction of architects -
Including the cost of 15mm x 15mm x 3mm SS
Channel & 18mm Revel. Note: Do not include base
partition & framing for quote.

2.1 Fabric Panelling Sqm 17.55 2,800 49,140

3 of 48
Sr.No Description Unit Qty Rate Amount REMARKS

FABRIC PANELING: Providing and fixing fabric


panelling fixed with fabric wrapped over UPVC Wall
tracts Gripper Pro stretch system with 12mm thick
MDF board with 3mm cushion backing fixed to the
-
hard wood framing / 12mm ply wood including all
hardware, fire retardant paint etc complete as per
design and drawing.Rate inclusive of gripper (Basic
Rate of fabric to be taken as RS. 450 Sq.mtr)

2.2 Column Cladding Modifying Sqm 17.33 400 6,930

GYPSUM CLADDING :- Providing and fixing of


12.5mm thick(Single layer) Gyp-board cladding
(Confirming to IS-2095-1982 and 2543-1982)over
existing partition/ with GI Frame work on screws
fixed with dry wall screw of 25mm at 300mm centre
-
square and tapered edges of the boards are to be
jointed and finished so as to have a flush look which
includes filling and finishing with jointing compound,
paper tape and two coats of primer suitable for
Gypboard to receive graphics .

2.3 Door Refurbishment Nos 3.00 12,500 37,500


Refurbishment of existing doors as per detailed
drawings with Door bedding & modification with door
fame including repolishing of existing veneer in 2
coats of melamine polish both side all necessary -
fittings.
( Hardware includes Hinges , Handle , open
door closer )
2.4 Veneer Panelling Sqm 4.50 3,250 14,625

VENEER PANNELING:-Providing and fixing 4mm


thick. veneer panelling of approved sample in one
group, fixed on existing 12mm thick . commercial ply
backing inclusive of match wood lapping, groove
-
should be provide within the veneer as directed
Inclusive of matt melamine polished to the veneer &
all the edges as directed. Basic Rate of Veneer is
INR 70/- per Sqft.

2.5 MDF Cladding for Graphics / Paint Sqm 36.80 775 28,520
MDF PANNELING:-Providing and fixing 12mm thick.
MDF fixing on existing Partition / Frame work with -
groove & necessary fixing.
2.6 Frost Film Sqm 27.00 1,150 31,050
FROSTED FILM (CRYSTAL QUALITY):- Providing
and fixing 3M / Avery / Birla scotchcal over glass
surface as approval of the Architect. (Height up to -
1200 , Only film surface area shall be measured
and paid)

B Breakout Area
Demolitions Ceiling / Partition / Floor / Panelling /
1.1
Grid Ceiling

DEMOLITION OF EXISTING CEILING: Demolition


of Existing Ceiling / Partition / Floor / Panelling / Grid
Ceiling including all framework and sheet and
disposal of unserviceable material as directed to
municipal dumping ground. Rate should include
safety precaution/measures taken to other
Lighting /AC/ or any other related fixtures while
carrying out the activites.Complete with all respect
as per Architect Instructions.

Ceiling Sqm 18.00 180 3,240


Grid Ceiling Sqm 18.00 180 3,240
Screeding Sqm 36.00 225 8,100
-
1.2 Screeding Sqm 36.00 425 15,300

4 of 48
Sr.No Description Unit Qty Rate Amount REMARKS

CEMENT CONCRETE SCREEDING:-Providing and


laying cement concrete for flooring to a maximum
75mm TO 100mm thick using cement concrete 1:2:4
(1cement :2Coarse sand :4graded stone aggregate
20mm and down gauge) for flooring bands and other
similar locations, tamped, spaded, toweled and top
finished neat, smooth with floating coat of cement as
-
directed laid in alternate panels of area not more
than 2 sqm and laid to water levels or proper slopes
as directed with necessary shuttering, hacking the
existing surface, curing etc. specifications. Rate are
inclusive of Junction box frame work & installation.
Complete with all respect as per detail drawing &
Architect Instructions.

1.3 Water Proofing Works Below Screeding Sqm 35.65 150 5,348

WATERPROOFING WORKS :- Providing and


applying water proofing coats slurry into existing slab
. Providing, supplying, mixing and applying cement
coats with water proofing compound of sunanda /
Roff make flexible water-proofing slurry to a
-
thickness of 1mm over the bottom , including
preparation of surface, finishing, curing etc. all
complete at different levels as specified by the
Architect as per manufacturer's specifications and as
directed.

1.4 Wooden finish Flooring Sqm 35.00 2,650 92,750


LAMINATED WOODEN FLOORING Basic Rate 180
INR /SQ.FT-Providing and laying laminated wooden
flooring in the form of planks of size 12 / 10mm
thick, laid on IPS base with 2mm form backing -
including edge profile/ beading wherever required all
complete as per Architects Instructions (Basic Rate
Rs. 180 Per Sqft )
1.5 Planter Box Rmt 4.00 5,500 22,000

CORIAN LEDGE(PLANTERS) : -Providing and fixing


of 6mm thick glacia white corian finish to be made in
hardwood framing. The 25 mm commercial board to
be fixed with 1mm thick laminate finished under -
structure as approved design. The rate to include the
pebbles of the width of 1200 mm wide as directed by
Architect.-laminate finish only

1.6 Designer Ceiling Sqm 35.00 1,050 36,750

Providing and fixing Gypsum False in Designer


Shape like Round / Oval ceiling of India Gypsum / La
gyp make which includes G.I. Perimeter Channels
of size 0.55 mm thick ( having One Flange of 20
mm. and another flange of 30 mm and a web of 27
mm ) along with perimeter of ceiling, screw fixed to
brick wall / partition with the help of Nylon sleeves
and screws at 610mm centres. Then suspending
G.I. intermediate channels of size 45mm (0.9mm
thick with 2 flanges of 15 mm each) from the soffit
at 1220 mm centres with ceiling angle of width 25
mm X 10 mm X 0.55 mm thick fixed to soffit with G.I.
cleat and steel expansion fasteners. Ceiling section
of 0.55mm thick having knurled web of 51.5 mm and
2 flanges of 26 mm each with lips of 10.5 mm are
then fixed to the intermediate channel with the help
of connecting clips and in direction perpendicular to
the intermediate channel at 450 mm centres.

5 of 48
Sr.No Description Unit Qty Rate Amount REMARKS

12.5mm tapered edge Gypboard (conforming to IS


2095-1982) is then screw fixed to ceiling section with
25mm dry wall Philips screws at 230mm centres.
Screw fixing is done mechanically with drilling
machine with suitable attachment. Finally tapered
edges of the Gyp boards are to be jointed and
finished so as to have a flush look which includes
filling and finishing with jointing compound, paper
tape etc complete as per the ASSESSMENT
practices of India Gypsum. Rate to be included all
kinds of profiles and cut outs required for light
fixtures, Speakers, Smoke detector, trap doors and
AC grill in the ceiling. The rate shall be inclusive of
Vertical Patties provided for fixing the gypsum ceiling
& also wherever height difference is there in ceiling.

C IT Service Area
Demolitions Ceiling / Partition / Floor / Panelling /
1.1
Grid Ceiling

DEMOLITION OF EXISTING CEILING: Demolition


of Existing Ceiling / Partition / Floor / Panelling / Grid
Ceiling including all framework and sheet and
disposal of unserviceable material as directed to
municipal dumping ground. Rate should include
safety precaution/measures taken to other
Lighting /AC/ or any other related fixtures while
carrying out the activites.Complete with all respect
as per Architect Instructions.

Partition & Panelling Sqm 58.00 225 13,050


Ceiling & Grid Ceiling Sqm 74.00 180 13,320
Screeding Sqm 33.00 225 7,425

1.1 Fire Rated Partition Sqm 122.10 2,300 280,830

FIRE RATED FULL HEIGHT PARTITION: Providing


and fixing frame of Full height 100mm thick partition
with GI 50 x 35 Framework @ 600 mm c/c both
ways (Fire retardant and anti-termite treated) up to
true ceiling finish with 12 mm bison board on both
side single layer & 1 layer of fire rated gypsum board
both side including glass wool insulation 50 mm thick
glass wool insulation of48 kg/ cum. density neatly
packed in tissue bags of various sizes and shapes,
bags shall be fully stitched all round with25 mm
double leaf fold, sealing the glass wool fibre fully.

The bags to be stuffed in the cavities of Gyp.


partitions from floor up to RCC slab above, cross
stitched from one side with GI frame work of partition
by 24 g GI wire to keep bags in position. UP
Twig/Rocklloyd make grade specified fixing to floor
& RCC roof with screw i/c provisions for grooves and
Fibber tape to be used for jointing and space/ cut-
outs for electrical sockets/switches and conduits etc.
as per detail drawings and specification and as
directed by Architect and duly fixed to floor/wall/RCC
roof with fasteners. Member placement to be worked
out as per grooves. complete as per drawing.

1.2 Slotted Angle Sqm 13.23 17,500 231,525

6 of 48
Sr.No Description Unit Qty Rate Amount REMARKS

SLOTTED ANGLE RACKS: Providing and fixing


storage in 20 gauge MS slotted angle of
35mmx35mm finished with approved shade powder
coating with 600mm wide 19mm thick PRE LAM
BOARD with laminated finish both side with 2mm
thick PVC edge binding. Rates are inclusive of all
necessary powder coated nut-bolt fittings, edge
guard bush for slotted angles etc. Complete with all
respect as per detail drawing and Architect
Instructions.

1.3 Filing Storage Sqm 5.60 7,200 40,320

FILING STORAGE :- Providing & fixing Full height


Storage cabinets 450 mm deep made out of 19mm
commercial board 1 mm thick laminate and
balancing laminate all inside adjustable laminated
shelves. Rate should be inclusive of necessary
Hardware- , Lock sets, self-closing hinges, spring
loaded shutter latch inside, all cabinet hardware as
approved & as /Architects approval. Hardware -
Hettich equivalent .

1.4 Modular Ceiling 0.5 NRC Sqm 80.00 950 76,000

GRID TILE CEILING: Providing & Fixing of


Armstrong Mineral Fibber Acoustical Suspended
Ceiling System with regular edge tiles should have
Humidity Resistance (RH) of 99%, NRC as mention
below, Light Reflectance >85%, Thermal
Conductivity k = 0.052- 0.057 w/m K, Colour White,
Fire Performance Class 0/Class1 (BS 476 Part 6&7)
in module size of 600 X 600 X 16 mm with Bio Block
coating on the face of the tile, suitable for Green
-
Building application, with Recycled content of
63%.The grid should be of “Armstrong” make with
silhouette with black groove - section flanges colour
white having rotary stitching on all T sections i.e. the
Main Runner, 1200 mm & 600 mm Cross Tees . The
T Sections have a Galvanizing of 120 grams per M2
& passed through 500 hrs of Salt test.The Tile & Grid
system used together should carry a 15 year
warrantee. Including Shadow line profile.

1.5 Wooden Door Nos 1.00 15,500 15,500

Providing and fixing Single leaf Flush Door 38mm


,both side approved Laminate finish & melamine
polish finish on edge with vision panel ( 1000mm x
150mm) of 6mm thk glass fixed on wooden beading
, shutter fixed on Wooden frame 105mm x 50mm
with door jamb fitting as per detail drawing . The
doors will have best quality 4 Nos 4" long SS hinges, -
SS finished double legged foot operated door stays,
Polyvinyl door stopper fixed to skirting, SS finish
25mm die 600mm high handle (OZONE), lock, with
OZONE make Open Door closer shall be include in
the cost of door. Complete as per detail drawing .
Door Size - 900 x 2400

1.6 False Flooring Removing & Refixing Sqm 15.60 850 13,260
1.7 Same as above but fixing with new tiles Sqm 10.00 2,950 29,500
D Meeting & Collaborative Area
Demolitions Ceiling / Partition / Floor / Panelling /
1.1
Grid Ceiling

7 of 48
Sr.No Description Unit Qty Rate Amount REMARKS

DEMOLITION OF EXISTING CEILING: Demolition


of Existing Ceiling / Partition / Floor / Panelling / Grid
Ceiling including all framework and sheet and
disposal of unserviceable material as directed to
municipal dumping ground. Rate should include
safety precaution/measures taken to other
Lighting /AC/ or any other related fixtures while
carrying out the activites.Complete with all respect
as per Architect Instructions.

Partition & Panelling Sqm 10.00 225 2,250


Ceiling Sqm 5.00 180 900
Grid Ceiling Sqm 4.00 180 720
Screeding Sqm 17.00 225 3,825

1.2 Screeding Sqm 17.00 425 7,225

CEMENT CONCRETE SCREEDING:-Providing and


laying cement concrete for flooring to a maximum
75mm TO 100mm thick using cement concrete 1:2:4
(1cement :2Coarse sand :4graded stone aggregate
20mm and down gauge) for flooring bands and other
similar locations, tamped, spaded, toweled and top
finished neat, smooth with floating coat of cement as
-
directed laid in alternate panels of area not more
than 2 sqm and laid to water levels or proper slopes
as directed with necessary shuttering, hacking the
existing surface, curing etc. specifications. Rate are
inclusive of Junction box frame work & installation.
Complete with all respect as per detail drawing &
Architect Instructions.

1.3 Water Proofing Works Below Screeding Sqm 11.00 150 1,650

WATERPROOFING WORKS :- Providing and


applying water proofing coats slurry into existing slab
. Providing, supplying, mixing and applying cement
coats with water proofing compound of sunanda /
Roff make flexible water-proofing slurry to a
-
thickness of 1mm over the bottom , including
preparation of surface, finishing, curing etc. all
complete at different levels as specified by the
Architect as per manufacturer's specifications and as
directed.

1.4 Door Refurbishment Nos 3.00 12,500 37,500


Refurbishment of existing doors as per detailed
drawings with Door bedding & modification with door
fame including repolishing of existing veneer in 2 -
coats of melamine polish both side all necessary
fittings.
1.5 A.V Cabinet - Refurbishment Sqm 6.80 4,000 27,200

AV CABINET : Refurbishment of Audio Visual


cabinet of with New laminate schemes & paint as
per architects instructions with finger groove shutter. -
NOTE: all hardware of ozone or equivalent. The rate
to include the cost to complete the entire item.

1.6 Ceiling Sqm 19.00 775 14,725

8 of 48
Sr.No Description Unit Qty Rate Amount REMARKS

Providing and fixing Gypsum False Ceiling of India


Gypsum / La gyp make which includes G.I.
Perimeter Channels of size 0.55 mm thick ( having
One Flange of 20 mm. and another flange of 30 mm
and a web of 27 mm ) along with perimeter of
ceiling, screw fixed to brick wall / partition with the
help of Nylon sleeves and screws at 610mm centres.
Then suspending G.I. intermediate channels of size
45mm (0.9mm thick with 2 flanges of 15 mm each)
-
from the soffit at 1220 mm centres with ceiling angle
of width 25 mm X 10 mm X 0.55 mm thick fixed to
soffit with G.I. cleat and steel expansion fasteners.
Ceiling section of 0.55mm thick having knurled web
of 51.5 mm and 2 flanges of 26 mm each with lips
of 10.5 mm are then fixed to the intermediate
channel with the help of connecting clips and in
direction perpendicular to the intermediate channel
at 450 mm centres.

12.5mm tapered edge Gypboard (conforming to IS


2095-1982) is then screw fixed to ceiling section with
25mm dry wall Philips screws at 230mm centres.
Screw fixing is done mechanically with drilling
machine with suitable attachment. Finally tapered
edges of the Gyp boards are to be jointed and
finished so as to have a flush look which includes
filling and finishing with jointing compound, paper -
tape etc complete as per the ASSESSMENT
practices of India Gypsum. Rate to be included all
kinds of profiles and cut outs required for light
fixtures, Speakers, Smoke detector, trap doors and
AC grill in the ceiling. The rate shall be inclusive of
Vertical Patties provided for fixing the gypsum ceiling
& also wherever height difference is there in ceiling.

1.7 Modular Ceiling 0.5 NRC Sqm 15.00 950 14,250

GRID TILE CEILING: Providing & Fixing of


Armstrong Mineral Fibber Acoustical Suspended
Ceiling System with regular edge tiles should have
Humidity Resistance (RH) of 99%, NRC as mention
below, Light Reflectance >85%, Thermal
Conductivity k = 0.052- 0.057 w/m K, Colour White,
Fire Performance Class 0/Class1 (BS 476 Part 6&7)
in module size of 600 X 600 X 16 mm with Bio Block
coating on the face of the tile, suitable for Green
-
Building application, with Recycled content of
63%.The grid should be of “Armstrong” make with
silhouette with black groove - section flanges colour
white having rotary stitching on all T sections i.e. the
Main Runner, 1200 mm & 600 mm Cross Tees . The
T Sections have a Galvanizing of 120 grams per M2
& passed through 500 hrs of Salt test.The Tile & Grid
system used together should carry a 15 year
warrantee. Including Shadow line profile.

1.8 Cabinet - Refurbishment Sqm RO 4,500


Cabinet : Refurbishment of cabinet of with new
laminate schemes as per architects instructions with
finger groove shutter. NOTE: all hardware of ozone -
or equivalent. The rate to include the cost to
complete the entire item.
1.9 Fabric Panelling Sqm 14.00 2,800 39,200

9 of 48
Sr.No Description Unit Qty Rate Amount REMARKS

FABRIC PANELING: Providing and fixing fabric


panelling fixed with fabric wrapped over UPVC Wall
tracts Gripper Pro stretch system with 12mm thick
MDF board with 3mm cushion backing fixed to the
-
hard wood framing / 12mm ply wood including all
hardware, fire retardant paint etc complete as per
design and drawing.Rate inclusive of gripper (Basic
Rate of fabric to be taken as RS. 450 Sq.mtr)

2.0 Glass Panelling Sqm 7.00 3,500 24,500


GLASS PANELLING :- Providing and fixing 6mm
thick Saint Gobin Planilaque white glass fixed with
3M double sided foam tapes on 9 plywood backing
-
with laminated strips as per instruction of architects .
Note: Do not include base partition & framing for
quote.
2.1 MDF Cladding Sqm 32.50 775 25,188
MDF PANNELING:-Providing and fixing 12mm thick.
MDF fixing on existing Partition / Frame work with -
groove including necessary fixing.
2.2 Repoilising of Existing Partition & Panelling Sqm 75.00 575 43,125
Appling 2 coats of melamine polish on existing
-
Veneer surface
Same as above but for moulding grooves & steps up
2.3 Rmt 30.00 185 5,550
to 12mm to 150mm .
2.4 Modifications of Glass Partitions Sqm 31.00 3,000 93,000
Modifications of Glass Partitions from partly glazed
to full glazed partition with four side wooden band
-
finish with laminate to match existing colour
scheme .
WALL PAPER :-Providing and fixing wall paper
(Vinyl wall covering) of approved make, on POP/
2.5 Gypboard surfaces with suitable adhesive as per Sqm 32.56 1,750 56,980
manufacturers specification.(Basic Rate of the
material to be taken as Rs. 150 / Sqft)
2.6 Frost Film Sqm 16.56 1,150 19,044
FROSTED FILM (CRYSTAL QUALITY):- Providing
and fixing 3M / Avery / Birla scotchcal over glass
surface as approval of the Architect. (Height up to -
1200 , Only film surface area shall be measured
and paid)
E Nirvana Near AHU Room -
Demolitions Ceiling / Partition / Floor / Panelling /
1.1 Sqm -
Grid Ceiling

DEMOLITION OF EXISTING CEILING: Demolition


of Existing Ceiling / Partition / Floor / Panelling / Grid
Ceiling including all framework and sheet and
disposal of unserviceable material as directed to
municipal dumping ground. Rate should include -
safety precaution/measures taken to other
Lighting /AC/ or any other related fixtures while
carrying out the activites.Complete with all respect
as per Architect Instructions.

Ceiling & Grid Ceiling Sqm 2.00 180 360


Grid Ceiling Sqm 3.00 180 540
Screeding Sqm 5.00 225 1,125
1.2 Screeding Sqm 5.00 425 2,125

10 of 48
Sr.No Description Unit Qty Rate Amount REMARKS

CEMENT CONCRETE SCREEDING:-Providing and


laying cement concrete for flooring to a maximum
75mm TO 100mm thick using cement concrete 1:2:4
(1cement :2Coarse sand :4graded stone aggregate
20mm and down gauge) for flooring bands and other
similar locations, tamped, spaded, toweled and top
finished neat, smooth with floating coat of cement as
-
directed laid in alternate panels of area not more
than 2 sqm and laid to water levels or proper slopes
as directed with necessary shuttering, hacking the
existing surface, curing etc. specifications. Rate are
inclusive of Junction box frame work & installation.
Complete with all respect as per detail drawing &
Architect Instructions.

1.3 Water Proofing Works Below Screeding Sqm 5.00 150 750

WATERPROOFING WORKS :- Providing and


applying water proofing coats slurry into existing slab
. Providing, supplying, mixing and applying cement
coats with water proofing compound of sunanda /
Roff make flexible water-proofing slurry to a
-
thickness of 1mm over the bottom , including
preparation of surface, finishing, curing etc. all
complete at different levels as specified by the
Architect as per manufacturer's specifications and as
directed.

1.4 Ceiling Sqm 3.00 775 2,325

Providing and fixing Gypsum False Ceiling of India


Gypsum / La gyp make which includes G.I.
Perimeter Channels of size 0.55 mm thick ( having
One Flange of 20 mm. and another flange of 30 mm
and a web of 27 mm ) along with perimeter of
ceiling, screw fixed to brick wall / partition with the
help of Nylon sleeves and screws at 610mm centres.
Then suspending G.I. intermediate channels of size
45mm (0.9mm thick with 2 flanges of 15 mm each)
-
from the soffit at 1220 mm centres with ceiling angle
of width 25 mm X 10 mm X 0.55 mm thick fixed to
soffit with G.I. cleat and steel expansion fasteners.
Ceiling section of 0.55mm thick having knurled web
of 51.5 mm and 2 flanges of 26 mm each with lips
of 10.5 mm are then fixed to the intermediate
channel with the help of connecting clips and in
direction perpendicular to the intermediate channel
at 450 mm centres.

12.5mm tapered edge Gypboard (conforming to IS


2095-1982) is then screw fixed to ceiling section with
25mm dry wall Philips screws at 230mm centres.
Screw fixing is done mechanically with drilling
machine with suitable attachment. Finally tapered
edges of the Gyp boards are to be jointed and
finished so as to have a flush look which includes
filling and finishing with jointing compound, paper -
tape etc complete as per the ASSESSMENT
practices of India Gypsum. Rate to be included all
kinds of profiles and cut outs required for light
fixtures, Speakers, Smoke detector, trap doors and
AC grill in the ceiling. The rate shall be inclusive of
Vertical Patties provided for fixing the gypsum ceiling
& also wherever height difference is there in ceiling.

1.5 Modular Ceiling 0.5 NRC Sqm 4.50 950 4,275

11 of 48
Sr.No Description Unit Qty Rate Amount REMARKS

GRID TILE CEILING: Providing & Fixing of


Armstrong Mineral Fibber Acoustical Suspended
Ceiling System with regular edge tiles should have
Humidity Resistance (RH) of 99%, NRC as mention
below, Light Reflectance >85%, Thermal
Conductivity k = 0.052- 0.057 w/m K, Colour White,
Fire Performance Class 0/Class1 (BS 476 Part 6&7)
in module size of 600 X 600 X 16 mm with Bio Block
coating on the face of the tile, suitable for Green
-
Building application, with Recycled content of
63%.The grid should be of “Armstrong” make with
silhouette with black groove - section flanges colour
white having rotary stitching on all T sections i.e. the
Main Runner, 1200 mm & 600 mm Cross Tees . The
T Sections have a Galvanizing of 120 grams per M2
& passed through 500 hrs of Salt test.The Tile & Grid
system used together should carry a 15 year
warrantee. Including Shadow line profile.

1.6 Door Refurbishment Nos 1.00 12,500 12,500


Refurbishment of existing doors as per detailed
drawings with Door bedding & modification with door
fame including repolishing of existing veneer in 2 -
coats of melamine polish both side all necessary
fittings.
1.7 Fabric Panelling Sqm 4.48 2,800 12,544

FABRIC PANELING: Providing and fixing fabric


panelling fixed with fabric wrapped over UPVC Wall
tracts Gripper Pro stretch system with 12mm thick
MDF board with 3mm cushion backing fixed to the
-
hard wood framing / 12mm ply wood including all
hardware, fire retardant paint etc complete as per
design and drawing.Rate inclusive of gripper (Basic
Rate of fabric to be taken as RS. 450 Sq.mtr)

1.8 MDF Cladding for Graphics / Paint Sqm 8.00 775 6,200
MDF PANNELING:-Providing and fixing 12mm thick.
MDF fixing on existing Partition / Frame work with -
groove including necessary fixing.
1.9 Glass Panelling Sqm 1.50 3,500 5,250
GLASS PANELLING :- Providing and fixing 6mm
thick Saint Gobin Planilaque white glass fixed with
3M double sided foam tapes on 9 plywood backing
-
with laminated strips as per instruction of architects
Note: Do not include base partition & framing for
quote.
2.0 Full Height Storages Sqm 8.55 7,200 61,560

FULL HEIGHT STORAGE :- Providing & fixing Full


height Storage cabinets 450 mm deep made out of
19mm commercial board 1 mm thick laminate and
balancing laminate all inside adjustable laminated
shelves. Rate should be inclusive of necessary -
Hardware- , Lock sets, self-closing hinges, spring
loaded shutter latch inside, all cabinet hardware as
approved & as /Architects approval. Hardware -
Hettich equivalent

2.1 Full Height / Ele DB Refurbishment Sqm 6.00 3,000 18,000


ELECTRICAL D.B. STORAGE:- Refurbishment of
DB shutters finished in 1mm thick. laminate Provide
150x300 duco painted louvered grills on each
shutter, requisite cut-outs for ventilation above and
servicing trap door below. Rate should be inclusive -
of necessary Hardware- handle, Lock sets, self-
closing hinges, spring loaded shutter latch inside
complete as per design and drawing Architects
approved .

12 of 48
Sr.No Description Unit Qty Rate Amount REMARKS

WALL PAPER :-Providing and fixing wall paper


(Vinyl wall covering) of approved make, on POP/
2.2 Gypboard surfaces with suitable adhesive as per Sqm 6.21 1,750 10,868
manufacturers specification.(Basic Rate of the
material to be taken as Rs. 150 / Sqft)
2.3 Frost Film Sqm 2.07 1,150 2,381
FROSTED FILM (CRYSTAL QUALITY):- Providing
and fixing 3M / Avery / Birla scotchcal over glass
surface as approval of the Architect. (Height up to -
1200 , Only film surface area shall be measured
and paid)
F 2P Quiet Room -
Demolitions Ceiling / Partition / Floor / Panelling /
1.1 Sqm
Grid Ceiling

DEMOLITION OF EXISTING CEILING: Demolition


of Existing Ceiling / Partition / Floor / Panelling / Grid
Ceiling including all framework and sheet and
disposal of unserviceable material as directed to
municipal dumping ground. Rate should include -
safety precaution/measures taken to other
Lighting /AC/ or any other related fixtures while
carrying out the activites.Complete with all respect
as per Architect Instructions.

Ceiling Sqm 1.50 180 270


Grid Ceiling Sqm 1.50 180 270
Screeding Sqm 3.00 225 675
1.2 Screeding Sqm 3.00 425 1,275

CEMENT CONCRETE SCREEDING:-Providing and


laying cement concrete for flooring to a maximum
75mm TO 100mm thick using cement concrete 1:2:4
(1cement :2Coarse sand :4graded stone aggregate
20mm and down gauge) for flooring bands and other
similar locations, tamped, spaded, toweled and top
finished neat, smooth with floating coat of cement as
-
directed laid in alternate panels of area not more
than 2 sqm and laid to water levels or proper slopes
as directed with necessary shuttering, hacking the
existing surface, curing etc. specifications. Rate are
inclusive of Junction box frame work & installation.
Complete with all respect as per detail drawing &
Architect Instructions.

1.3 Water Proofing Works Below Screeding Sqm 3.00 150 450

WATERPROOFING WORKS :- Providing and


applying water proofing coats slurry into existing slab
. Providing, supplying, mixing and applying cement
coats with water proofing compound of sunanda /
Roff make flexible water-proofing slurry to a
-
thickness of 1mm over the bottom , including
preparation of surface, finishing, curing etc. all
complete at different levels as specified by the
Architect as per manufacturer's specifications and as
directed.

1.4 Partition -Gypsum Sqm 7.20 1,500 10,800

FULL HEIGHT PARTITION: Providing and fixing


frame of Full height 75mm thick partition with GI
Framework @ 600 mm c/c both ways (Fire retardant
and anti-termite treated) up to 2700 mm finish with
12 mm ply wood & above , till true ceiling finished
with both side one layer of 12.5mm thk Gypsum
-
board on either side with glass wool insulation 50
mm thick glass wool insulation of48 kg/ cum. density
neatly packed in tissue bags of various sizes and
shapes, bags shall be fully stitched all round with25
mm double leaf fold, sealing the glass wool fibre
fully.

13 of 48
Sr.No Description Unit Qty Rate Amount REMARKS

The bags to be stuffed in the cavities of Gyp.


partitions from floor up to RCC slab above, cross
stitched from one side with GI frame work of partition
by 24 g GI wire to keep bags in position. UP
Twig/Rocklloyd make grade specified fixing to floor
& RCC roof with screw i/c provisions for grooves and
-
Fibber tape to be used for jointing and space/ cut-
outs for electrical sockets/switches and conduits etc.
as per detail drawings and specification and as
directed by Architect and duly fixed to floor/wall/RCC
roof with fasteners. Member placement to be worked
out as per grooves. complete as per drawing.

Note : - All vertical & Horizontal edges will be


covered 12mm MDF with paint finish . To receive
-
modular partition section & making pen tray cut outs
as directed by architects .
1.5 Wooden Door Nos 1.00 15,500 15,500

Providing and fixing Single leaf Flush Door ,both


side approved Laminate finish & melamine polish
finish on edge with vision panel of 6mm thk glass
fixed on wooden beading , shutter fixed on Wooden
frame 105mm x 50mm with door jamb fitting as per
detail drawing . The doors will have best quality 4
-
Nos 4" long SS hinges, SS finished double legged
foot operated door stays, Polyvinyl door stopper
fixed to skirting, SS finish 25mm die 600mm high
handle (OZONE), lock, with OZONE make
Concealed Door closer shall be include in the cost of
door. Complete as per detail drawing .

1.6 Ceiling Sqm RO 775

Providing and fixing Gypsum False Ceiling of India


Gypsum / La gyp make which includes G.I.
Perimeter Channels of size 0.55 mm thick ( having
One Flange of 20 mm. and another flange of 30 mm
and a web of 27 mm ) along with perimeter of
ceiling, screw fixed to brick wall / partition with the
help of Nylon sleeves and screws at 610mm centres.
Then suspending G.I. intermediate channels of size
45mm (0.9mm thick with 2 flanges of 15 mm each)
-
from the soffit at 1220 mm centres with ceiling angle
of width 25 mm X 10 mm X 0.55 mm thick fixed to
soffit with G.I. cleat and steel expansion fasteners.
Ceiling section of 0.55mm thick having knurled web
of 51.5 mm and 2 flanges of 26 mm each with lips
of 10.5 mm are then fixed to the intermediate
channel with the help of connecting clips and in
direction perpendicular to the intermediate channel
at 450 mm centres.

12.5mm tapered edge Gypboard (conforming to IS


2095-1982) is then screw fixed to ceiling section with
25mm dry wall Philips screws at 230mm centres.
Screw fixing is done mechanically with drilling
machine with suitable attachment. Finally tapered
edges of the Gyp boards are to be jointed and
finished so as to have a flush look which includes
filling and finishing with jointing compound, paper -
tape etc complete as per the ASSESSMENT
practices of India Gypsum. Rate to be included all
kinds of profiles and cut outs required for light
fixtures, Speakers, Smoke detector, trap doors and
AC grill in the ceiling. The rate shall be inclusive of
Vertical Patties provided for fixing the gypsum ceiling
& also wherever height difference is there in ceiling.

1.7 Modular Ceiling 0.5 NRC Sqm 4.50 950 4,275

14 of 48
Sr.No Description Unit Qty Rate Amount REMARKS

GRID TILE CEILING: Providing & Fixing of


Armstrong Mineral Fibber Acoustical Suspended
Ceiling System with regular edge tiles should have
Humidity Resistance (RH) of 99%, NRC as mention
below, Light Reflectance >85%, Thermal
Conductivity k = 0.052- 0.057 w/m K, Colour White,
Fire Performance Class 0/Class1 (BS 476 Part 6&7)
in module size of 600 X 600 X 16 mm with Bio Block
coating on the face of the tile, suitable for Green
-
Building application, with Recycled content of
63%.The grid should be of “Armstrong” make with
silhouette with black groove - section flanges colour
white having rotary stitching on all T sections i.e. the
Main Runner, 1200 mm & 600 mm Cross Tees . The
T Sections have a Galvanizing of 120 grams per M2
& passed through 500 hrs of Salt test.The Tile & Grid
system used together should carry a 15 year
warrantee. Including Shadow line profile.

1.8 Glazed Partition Sqm 7.68 4,650 35,712

Providing & fixing glass partition of 10mm toughened


glass with wooden frame work in 12 mm ply wood
-
boxing finish with laminate 100 X 100 mm high
boxing as per existing site condition

1.9 DB Shutter Sqm 5.00 3,000 15,000

ELECTRICAL D.B. STORAGE:- Refurbishment of


DB shutters finished in 1mm thick. laminate Provide
150x300 duco painted louvered grills on each
shutter, requisite cut-outs for ventilation above and
servicing trap door below. Rate should be inclusive -
of necessary Hardware- handle, Lock sets, self-
closing hinges, spring loaded shutter latch inside
complete as per design and drawing Architects
approved .
2.0 Laminate Ledge Rmt 2.50 1,900 4,750
Providing & fixing laminate finish ledge made out of
-
25mm thick plywood with necessary fitting .
WALL PAPER :-Providing and fixing wall paper
(Vinyl wall covering) of approved make, on POP/
2.1 Gypboard surfaces with suitable adhesive as per Sqm 6.83 1,750 11,954
manufacturers specification.(Basic Rate of the
material to be taken as Rs. 150 / Sqft)
2.2 Frost Film Sqm 2.76 1,150 3,174
FROSTED FILM (CRYSTAL QUALITY):- Providing
and fixing 3M / Avery / Birla scotchcal over glass
surface as approval of the Architect. (Height up to -
1200 , Only film surface area shall be measured
and paid)
G 10P Meeting Room -
Demolitions Ceiling / Partition / Floor / Panelling /
1.1 -
Grid Ceiling

DEMOLITION OF EXISTING CEILING: Demolition


of Existing Ceiling / Partition / Floor / Panelling / Grid
Ceiling including all framework and sheet and
disposal of unserviceable material as directed to
municipal dumping ground. Rate should include -
safety precaution/measures taken to other
Lighting /AC/ or any other related fixtures while
carrying out the activites.Complete with all respect
as per Architect Instructions.

Ceiling Sqm 8.00 180 1,440


Grid Ceiling Sqm 7.00 180 1,260
Screeding Sqm 15.00 225 3,375
1.2 Screeding Sqm 15.00 425 6,375

15 of 48
Sr.No Description Unit Qty Rate Amount REMARKS

CEMENT CONCRETE SCREEDING:-Providing and


laying cement concrete for flooring to a maximum
75mm TO 100mm thick using cement concrete 1:2:4
(1cement :2Coarse sand :4graded stone aggregate
20mm and down gauge) for flooring bands and other
similar locations, tamped, spaded, toweled and top
finished neat, smooth with floating coat of cement as
-
directed laid in alternate panels of area not more
than 2 sqm and laid to water levels or proper slopes
as directed with necessary shuttering, hacking the
existing surface, curing etc. specifications. Rate are
inclusive of Junction box frame work & installation.
Complete with all respect as per detail drawing &
Architect Instructions.

1.3 Water Proofing Works Below Screeding Sqm 15.00 150 2,250

WATERPROOFING WORKS :- Providing and


applying water proofing coats slurry into existing slab
. Providing, supplying, mixing and applying cement
coats with water proofing compound of sunanda /
Roff make flexible water-proofing slurry to a
-
thickness of 1mm over the bottom , including
preparation of surface, finishing, curing etc. all
complete at different levels as specified by the
Architect as per manufacturer's specifications and as
directed.

1.4 Door Refurbishment Nos 1.00 12,500 12,500


Refurbishment of existing doors as per detailed
drawings with Door bedding & modification with door
fame including repolishing of existing veneer in 2 -
coats of melamine polish both side all necessary
fittings.
1.5 Fabric Panelling Sqm 8.00 2,800 22,400

FABRIC PANELING: Providing and fixing fabric


panelling fixed with fabric wrapped over UPVC Wall
tracts Gripper Pro stretch system with 12mm thick
MDF board with 3mm cushion backing fixed to the
-
hard wood framing / 12mm ply wood including all
hardware, fire retardant paint etc complete as per
design and drawing.Rate inclusive of gripper (Basic
Rate of fabric to be taken as RS. 450 Sq.mtr)

1.6 Glass Panelling Sqm 3.00 3,500 10,500


GLASS PANELLING :- Providing and fixing 6mm
thick Saint Gobin Planilaque white glass fixed with
3M double sided foam tapes on 9 plywood backing
-
with laminated strips as per instruction of architects.
Note: Do not include base partition & framing for
quote.
1.7 Storage Refurbishment Sqm 3.00 4,150 12,450
Refurbishment of existing Storage cabinets 450 mm
deep finish with new 1 mm thick laminate . Rate
should be inclusive of necessary Hardware- , Lock
sets, self-closing hinges, spring loaded shutter latch -
inside, all cabinet hardware as approved & as
/Architects approval. Hardware - Hettich equivalent

1.8 Modular Ceiling 0.5 NRC Sqm 7.00 950 6,650

16 of 48
Sr.No Description Unit Qty Rate Amount REMARKS

GRID TILE CEILING: Providing & Fixing of


Armstrong Mineral Fibber Acoustical Suspended
Ceiling System with regular edge tiles should have
Humidity Resistance (RH) of 99%, NRC as mention
below, Light Reflectance >85%, Thermal
Conductivity k = 0.052- 0.057 w/m K, Colour White,
Fire Performance Class 0/Class1 (BS 476 Part 6&7)
in module size of 600 X 600 X 16 mm with Bio Block
coating on the face of the tile, suitable for Green
-
Building application, with Recycled content of
63%.The grid should be of “Armstrong” make with
silhouette with black groove - section flanges colour
white having rotary stitching on all T sections i.e. the
Main Runner, 1200 mm & 600 mm Cross Tees . The
T Sections have a Galvanizing of 120 grams per M2
& passed through 500 hrs of Salt test.The Tile & Grid
system used together should carry a 15 year
warrantee. Including Shadow line profile.

1.9 Ceiling Sqm 14.00 775 10,850 #VALUE!

Providing and fixing Gypsum False Ceiling of India


Gypsum / La gyp make which includes G.I.
Perimeter Channels of size 0.55 mm thick ( having
One Flange of 20 mm. and another flange of 30 mm
and a web of 27 mm ) along with perimeter of
ceiling, screw fixed to brick wall / partition with the
help of Nylon sleeves and screws at 610mm centres.
Then suspending G.I. intermediate channels of size
45mm (0.9mm thick with 2 flanges of 15 mm each)
-
from the soffit at 1220 mm centres with ceiling angle
of width 25 mm X 10 mm X 0.55 mm thick fixed to
soffit with G.I. cleat and steel expansion fasteners.
Ceiling section of 0.55mm thick having knurled web
of 51.5 mm and 2 flanges of 26 mm each with lips
of 10.5 mm are then fixed to the intermediate
channel with the help of connecting clips and in
direction perpendicular to the intermediate channel
at 450 mm centres.

12.5mm tapered edge Gypboard (conforming to IS


2095-1982) is then screw fixed to ceiling section with
25mm dry wall Philips screws at 230mm centres.
Screw fixing is done mechanically with drilling
machine with suitable attachment. Finally tapered
edges of the Gyp boards are to be jointed and
finished so as to have a flush look which includes
filling and finishing with jointing compound, paper -
tape etc complete as per the ASSESSMENT
practices of India Gypsum. Rate to be included all
kinds of profiles and cut outs required for light
fixtures, Speakers, Smoke detector, trap doors and
AC grill in the ceiling. The rate shall be inclusive of
Vertical Patties provided for fixing the gypsum ceiling
& also wherever height difference is there in ceiling.

2.0 MDF Cladding for Graphics / Paint Sqm 15.00 2,250 33,750
MDF PANNELING:-Providing and fixing 12mm thick.
MDF fixing on existing Partition / Frame work with -
groove including necessary fixing.
WALL PAPER :-Providing and fixing wall paper
(Vinyl wall covering) of approved make, on POP/
2.1 Gypboard surfaces with suitable adhesive as per Sqm 12.11 2,000 24,219
manufacturers specification.(Basic Rate of the
material to be taken as Rs. 150 / Sqft)

H 2P Quiet Room Near Conf.Room & Conf. Room

Demolitions Ceiling / Partition / Floor / Panelling /


1.1
Grid Ceiling

17 of 48
Sr.No Description Unit Qty Rate Amount REMARKS

DEMOLITION OF EXISTING CEILING: Demolition


of Existing Ceiling / Partition / Floor / Panelling / Grid
Ceiling including all framework and sheet and
disposal of unserviceable material as directed to
municipal dumping ground. Rate should include
safety precaution/measures taken to other
Lighting /AC/ or any other related fixtures while
carrying out the activites.Complete with all respect
as per Architect Instructions.

Partition Sqm 16.00 225 3,600


Gypsum Ceiling Sqm 10.00 180 1,800
Grid Ceiling Sqm 10.00 180 1,800
Screeding Sqm 33.00 225 7,425
1.2 Screeding Sqm 33.00 400 13,200

CEMENT CONCRETE SCREEDING:-Providing and


laying cement concrete for flooring to a maximum
75mm TO 100mm thick using cement concrete 1:2:4
(1cement :2Coarse sand :4graded stone aggregate
20mm and down gauge) for flooring bands and other
similar locations, tamped, spaded, toweled and top
finished neat, smooth with floating coat of cement as
-
directed laid in alternate panels of area not more
than 2 sqm and laid to water levels or proper slopes
as directed with necessary shuttering, hacking the
existing surface, curing etc. specifications. Rate are
inclusive of Junction box frame work & installation.
Complete with all respect as per detail drawing &
Architect Instructions.

1.3 Water Proofing Works Below Screeding Sqm 33.00 150 4,950

WATERPROOFING WORKS :- Providing and


applying water proofing coats slurry into existing slab
. Providing, supplying, mixing and applying cement
coats with water proofing compound of sunanda /
Roff make flexible water-proofing slurry to a
-
thickness of 1mm over the bottom , including
preparation of surface, finishing, curing etc. all
complete at different levels as specified by the
Architect as per manufacturer's specifications and as
directed.

1.4 Solid Partition -Gypsum Sqm 22.08 1,500 33,120

FULL HEIGHT PARTITION: Providing and fixing


frame of Full height 75mm thick partition with GI
Framework @ 600 mm c/c both ways (Fire retardant
and anti-termite treated) up to 2700 mm finish with
12 mm ply wood & above , till true ceiling finished
with both side one layer of 12.5mm thk Gypsum
-
board on either side with glass wool insulation 50
mm thick glass wool insulation of48 kg/ cum. density
neatly packed in tissue bags of various sizes and
shapes, bags shall be fully stitched all round with25
mm double leaf fold, sealing the glass wool fibre
fully.

The bags to be stuffed in the cavities of Gyp.


partitions from floor up to RCC slab above, cross
stitched from one side with GI frame work of partition
by 24 g GI wire to keep bags in position. UP
Twig/Rocklloyd make grade specified fixing to floor
& RCC roof with screw i/c provisions for grooves and
-
Fibber tape to be used for jointing and space/ cut-
outs for electrical sockets/switches and conduits etc.
as per detail drawings and specification and as
directed by Architect and duly fixed to floor/wall/RCC
roof with fasteners. Member placement to be worked
out as per grooves. complete as per drawing.

18 of 48
Sr.No Description Unit Qty Rate Amount REMARKS

Note : - All vertical & Horizontal edges will be


covered 12mm MDF with paint finish . To receive
-
modular partition section & making pen tray cut outs
as directed by architects .
1.5 Glazed Partition in wooden Sqm 5.00 4,300 21,500
Providing & Fixing glazed partition to full glazed
partition with four side wooden band finish with -
laminate to match existing colour scheme .
1.6 Door Refurbishment No's 3.00 12,500 37,500
Refurbishment of existing doors as per detailed
drawings with Door bedding & modification with door
fame including repolishing of existing veneer in 2 -
coats of melamine polish both side all necessary
fittings.
1.6A Wooden Door Nos 1.00 15,500 15,500

Providing and fixing Single leaf Flush Door ,both


side approved Laminate finish & melamine polish
finish on edge with vision panel of 6mm thk glass
fixed on wooden beading , shutter fixed on Wooden
frame 105mm x 50mm with door jamb fitting as per
detail drawing . The doors will have best quality 4
-
Nos 4" long SS hinges, SS finished double legged
foot operated door stays, Polyvinyl door stopper
fixed to skirting, SS finish 25mm die 600mm high
handle (OZONE), lock, with OZONE make Open
Door closer shall be include in the cost of door.
Complete as per detail drawing .

Refurbishment of Conference Table Repolishing of


1.7 existing table with new wire management system as L.S 1.00 40,000 40,000
per architects requirement .
1.8 MDF Cladding for Graphics / Paint Sqm 25.00 2,250 56,250

MDF PANNELING:-Providing and fixing 12mm thick.


MDF fixing on existing Partition / Frame work with -
groove S.S profile with necessary fixing.

1.9 Fabric Panelling Sqm 16.00 2,800 44,800

FABRIC PANELING: Providing and fixing fabric


panelling fixed with fabric wrapped over UPVC Wall
tracts Gripper Pro stretch system with 12mm thick
MDF board with 3mm cushion backing fixed to the
-
hard wood framing / 12mm ply wood including all
hardware, fire retardant paint etc complete as per
design and drawing.Rate inclusive of gripper (Basic
Rate of fabric to be taken as RS. 450 Sq.mtr)

2.0 Glass Panelling Sqm 12.00 3,500 42,000


GLASS PANELLING :- Providing and fixing 6mm
thick Saint Gobin Planilaque white glass fixed with
3M double sided foam tapes on 9 plywood backing
-
with laminated strips as per instruction of architects.
Note: Do not include base partition & framing for
quote.
2.1 Laminate Ledge Rmt 3.00 1,900 5,700
Providing & fixing laminated ledge of 25mm thick
-
with necessary fitting .
2.2 Repoilising of Existing Partition & Panelling Sqm 125.00 575 71,875
Appling 2 coats of melamine polish on existing
-
Veneer surface
Same as above but for moulding grooves & steps up
2.3 Rmt 125.00 185 23,125
to 12mm to 150mm .
2.4 Ceiling Sqm 35.00 775 27,125

19 of 48
Sr.No Description Unit Qty Rate Amount REMARKS

Providing and fixing Gypsum False Ceiling of India


Gypsum / La gyp make which includes G.I.
Perimeter Channels of size 0.55 mm thick ( having
One Flange of 20 mm. and another flange of 30 mm
and a web of 27 mm ) along with perimeter of
ceiling, screw fixed to brick wall / partition with the
help of Nylon sleeves and screws at 610mm centres.
Then suspending G.I. intermediate channels of size
45mm (0.9mm thick with 2 flanges of 15 mm each)
-
from the soffit at 1220 mm centres with ceiling angle
of width 25 mm X 10 mm X 0.55 mm thick fixed to
soffit with G.I. cleat and steel expansion fasteners.
Ceiling section of 0.55mm thick having knurled web
of 51.5 mm and 2 flanges of 26 mm each with lips
of 10.5 mm are then fixed to the intermediate
channel with the help of connecting clips and in
direction perpendicular to the intermediate channel
at 450 mm centres.

12.5mm tapered edge Gypboard (conforming to IS


2095-1982) is then screw fixed to ceiling section with
25mm dry wall Philips screws at 230mm centres.
Screw fixing is done mechanically with drilling
machine with suitable attachment. Finally tapered
edges of the Gyp boards are to be jointed and
finished so as to have a flush look which includes
filling and finishing with jointing compound, paper -
tape etc complete as per the ASSESSMENT
practices of India Gypsum. Rate to be included all
kinds of profiles and cut outs required for light
fixtures, Speakers, Smoke detector, trap doors and
AC grill in the ceiling. The rate shall be inclusive of
Vertical Patties provided for fixing the gypsum ceiling
& also wherever height difference is there in ceiling.

2.5 Modular Ceiling 0.5 NRC Sqm 5.00 950 4,750

GRID TILE CEILING: Providing & Fixing of


Armstrong Mineral Fibber Acoustical Suspended
Ceiling System with regular edge tiles should have
Humidity Resistance (RH) of 99%, NRC as mention
below, Light Reflectance >85%, Thermal
Conductivity k = 0.052- 0.057 w/m K, Colour White,
Fire Performance Class 0/Class1 (BS 476 Part 6&7)
in module size of 600 X 600 X 16 mm with Bio Block
coating on the face of the tile, suitable for Green
-
Building application, with Recycled content of
63%.The grid should be of “Armstrong” make with
silhouette with black groove - section flanges colour
white having rotary stitching on all T sections i.e. the
Main Runner, 1200 mm & 600 mm Cross Tees . The
T Sections have a Galvanizing of 120 grams per M2
& passed through 500 hrs of Salt test.The Tile & Grid
system used together should carry a 15 year
warrantee. Including Shadow line profile.

WALL PAPER :-Providing and fixing wall paper


(Vinyl wall covering) of approved make, on POP/
2.6 Gypboard surfaces with suitable adhesive as per Sqm 20.80 1,750 36,406
manufacturers specification.(Basic Rate of the
material to be taken as Rs. 150 / Sqft)
2.5 Frost Film Sqm 1.79 1,150 2,063
FROSTED FILM (CRYSTAL QUALITY):- Providing
and fixing 3M / Avery / Birla scotchcal over glass
surface as approval of the Architect. (Height up to -
1200 , Only film surface area shall be measured
and paid)
I 7 P & 3 P Meeting Room -
Demolitions Ceiling / Partition / Floor / Panelling /
1.1 Sqm
Grid Ceiling
20 of 48
Sr.No Description Unit Qty Rate Amount REMARKS

DEMOLITION OF EXISTING CEILING: Demolition


of Existing Ceiling / Partition / Floor / Panelling / Grid
Ceiling including all framework and sheet and
disposal of unserviceable material as directed to
municipal dumping ground. Rate should include -
safety precaution/measures taken to other
Lighting /AC/ or any other related fixtures while
carrying out the activites.Complete with all respect
as per Architect Instructions.

Partition Sqm 3.00 225 675


Gypsum Ceiling Sqm 3.00 180 540
Grid Ceiling Sqm 4.00 180 720
Screeding Sqm 8.00 225 1,800
1.2 Screeding Sqm 18.00 400 7,200

CEMENT CONCRETE SCREEDING:-Providing and


laying cement concrete for flooring to a maximum
75mm TO 100mm thick using cement concrete 1:2:4
(1cement :2Coarse sand :4graded stone aggregate
20mm and down gauge) for flooring bands and other
similar locations, tamped, spaded, toweled and top
finished neat, smooth with floating coat of cement as
-
directed laid in alternate panels of area not more
than 2 sqm and laid to water levels or proper slopes
as directed with necessary shuttering, hacking the
existing surface, curing etc. specifications. Rate are
inclusive of Junction box frame work & installation.
Complete with all respect as per detail drawing &
Architect Instructions.

1.3 Water Proofing Works Below Screeding Sqm 18.00 150 2,700

WATERPROOFING WORKS :- Providing and


applying water proofing coats slurry into existing slab
. Providing, supplying, mixing and applying cement
coats with water proofing compound of sunanda /
Roff make flexible water-proofing slurry to a
-
thickness of 1mm over the bottom , including
preparation of surface, finishing, curing etc. all
complete at different levels as specified by the
Architect as per manufacturer's specifications and as
directed.

1.4 Partition -Gypsum Sqm 28.80 1,500 43,200

P1 FULL HEIGHT PARTITION: Providing and fixing


frame of Full height 75mm thick partition with GI
Framework @ 600 mm c/c both ways (Fire retardant
and anti-termite treated) up to 2700 mm finish with
12 mm ply wood & above , till true ceiling finished
with both side one layer of 12.5mm thk Gypsum
-
board on either side with glass wool insulation 50
mm thick glass wool insulation of48 kg/ cum. density
neatly packed in tissue bags of various sizes and
shapes, bags shall be fully stitched all round with25
mm double leaf fold, sealing the glass wool fibre
fully.

The bags to be stuffed in the cavities of Gyp.


partitions from floor up to RCC slab above, cross
stitched from one side with GI frame work of partition
by 24 g GI wire to keep bags in position. UP
Twig/Rocklloyd make grade specified fixing to floor
& RCC roof with screw i/c provisions for grooves and
-
Fibber tape to be used for jointing and space/ cut-
outs for electrical sockets/switches and conduits etc.
as per detail drawings and specification and as
directed by Architect and duly fixed to floor/wall/RCC
roof with fasteners. Member placement to be worked
out as per grooves. complete as per drawing.

21 of 48
Sr.No Description Unit Qty Rate Amount REMARKS

Note : - All vertical & Horizontal edges will be


covered 12mm MDF with paint finish . To receive
-
modular partition section & making pen tray cut outs
as directed by architects .
1.5 Glazed Partition Sqm RO 4,650
Providing & fixing glass partition of 10mm toughened
glass with wooden frame work finish with melamine -
polish
1.6 Fabric Panelling Sqm 8.00 2,800 22,400

FABRIC PANELING: Providing and fixing fabric


panelling fixed with fabric wrapped over UPVC Wall
tracts Gripper Pro stretch system with 12mm thick
MDF board with 3mm cushion backing fixed to the
-
hard wood framing / 12mm ply wood including all
hardware, fire retardant paint etc complete as per
design and drawing.Rate inclusive of gripper (Basic
Rate of fabric to be taken as RS. 450 Sq.mtr)

1.7 MDF Cladding for Graphics / Paint Sqm 20.00 775 15,500
MDF PANNELING:-Providing and fixing 12mm thick.
MDF fixing on existing Partition / Frame work with -
groove including necessary fixing.
1.8 Glass Panelling Sqm 6.00 3,500 21,000
GLASS PANELLING :- Providing and fixing 6mm
thick Saint Gobin Planilaque white glass fixed with
3M double sided foam tapes on 9 plywood backing
-
with laminated strips as per instruction of architects.
Note: Do not include base partition & framing for
quote.
1.9 Laminate Ledge Rmt 3.00 1,900 5,700
Providing & fixing laminated ledge of 25mm thick
-
with necessary fitting .
2.0 Door Refurbishment No's 2.00 12,500 25,000
Refurbishment of existing doors as per detailed
drawings with repolishing of existing veneer in 3
-
coats of melamine polish both side all necessary
fittings.
2.1 Modular Ceiling 0.5 NRC Sqm 15.00 950 14,250

GRID TILE CEILING: Providing & Fixing of


Armstrong Mineral Fibber Acoustical Suspended
Ceiling System with regular edge tiles should have
Humidity Resistance (RH) of 99%, NRC as mention
below, Light Reflectance >85%, Thermal
Conductivity k = 0.052- 0.057 w/m K, Colour White,
Fire Performance Class 0/Class1 (BS 476 Part 6&7)
in module size of 600 X 600 X 16 mm with Bio Block
coating on the face of the tile, suitable for Green
-
Building application, with Recycled content of
63%.The grid should be of “Armstrong” make with
silhouette with black groove - section flanges colour
white having rotary stitching on all T sections i.e. the
Main Runner, 1200 mm & 600 mm Cross Tees . The
T Sections have a Galvanizing of 120 grams per M2
& passed through 500 hrs of Salt test.The Tile & Grid
system used together should carry a 15 year
warrantee. Including Shadow line profile.

2.2 Ceiling Sqm 10.00 775 7,750

22 of 48
Sr.No Description Unit Qty Rate Amount REMARKS

Providing and fixing Gypsum False Ceiling of India


Gypsum / La gyp make which includes G.I.
Perimeter Channels of size 0.55 mm thick ( having
One Flange of 20 mm. and another flange of 30 mm
and a web of 27 mm ) along with perimeter of
ceiling, screw fixed to brick wall / partition with the
help of Nylon sleeves and screws at 610mm centres.
Then suspending G.I. intermediate channels of size
45mm (0.9mm thick with 2 flanges of 15 mm each)
-
from the soffit at 1220 mm centres with ceiling angle
of width 25 mm X 10 mm X 0.55 mm thick fixed to
soffit with G.I. cleat and steel expansion fasteners.
Ceiling section of 0.55mm thick having knurled web
of 51.5 mm and 2 flanges of 26 mm each with lips
of 10.5 mm are then fixed to the intermediate
channel with the help of connecting clips and in
direction perpendicular to the intermediate channel
at 450 mm centres.

12.5mm tapered edge Gypboard (conforming to IS


2095-1982) is then screw fixed to ceiling section with
25mm dry wall Philips screws at 230mm centres.
Screw fixing is done mechanically with drilling
machine with suitable attachment. Finally tapered
edges of the Gyp boards are to be jointed and
finished so as to have a flush look which includes
filling and finishing with jointing compound, paper -
tape etc complete as per the ASSESSMENT
practices of India Gypsum. Rate to be included all
kinds of profiles and cut outs required for light
fixtures, Speakers, Smoke detector, trap doors and
AC grill in the ceiling. The rate shall be inclusive of
Vertical Patties provided for fixing the gypsum ceiling
& also wherever height difference is there in ceiling.

WALL PAPER :-Providing and fixing wall paper


(Vinyl wall covering) of approved make, on POP/
2.3 Gypboard surfaces with suitable adhesive as per Sqm 19.56 1,750 34,233
manufacturers specification.(Basic Rate of the
material to be taken as Rs. 150 / Sqft)
2.4 Frost Film Sqm 2.07 1,150 2,381
FROSTED FILM (CRYSTAL QUALITY):- Providing
and fixing 3M / Avery / Birla scotchcal over glass
surface as approval of the Architect. (Height up to -
1200 , Only film surface area shall be measured
and paid)
J 4 P Meeting Room & Nirvana -
Demolitions Ceiling / Partition / Floor / Panelling /
1.1 -
Grid Ceiling

DEMOLITION OF EXISTING CEILING: Demolition


of Existing Ceiling / Partition / Floor / Panelling / Grid
Ceiling including all framework and sheet and
disposal of unserviceable material as directed to
municipal dumping ground. Rate should include -
safety precaution/measures taken to other
Lighting /AC/ or any other related fixtures while
carrying out the activites.Complete with all respect
as per Architect Instructions.

Screeding Sqm 10.00 225 2,250


1.2 Screeding Sqm 10.00 425 4,250

23 of 48
Sr.No Description Unit Qty Rate Amount REMARKS

CEMENT CONCRETE SCREEDING:-Providing and


laying cement concrete for flooring to a maximum
75mm TO 100mm thick using cement concrete 1:2:4
(1cement :2Coarse sand :4graded stone aggregate
20mm and down gauge) for flooring bands and other
similar locations, tamped, spaded, toweled and top
finished neat, smooth with floating coat of cement as
-
directed laid in alternate panels of area not more
than 2 sqm and laid to water levels or proper slopes
as directed with necessary shuttering, hacking the
existing surface, curing etc. specifications. Rate are
inclusive of Junction box frame work & installation.
Complete with all respect as per detail drawing &
Architect Instructions.

1.3 Water Proofing Works Below Screeding Sqm 10.00 150 1,500

WATERPROOFING WORKS :- Providing and


applying water proofing coats slurry into existing slab
. Providing, supplying, mixing and applying cement
coats with water proofing compound of sunanda /
Roff make flexible water-proofing slurry to a
-
thickness of 1mm over the bottom , including
preparation of surface, finishing, curing etc. all
complete at different levels as specified by the
Architect as per manufacturer's specifications and as
directed.

1.4 Partition -Gypsum Sqm 53.12 1,500 79,680

P1 FULL HEIGHT PARTITION: Providing and fixing


frame of Full height 75mm thick partition with GI
Framework @ 600 mm c/c both ways (Fire retardant
and anti-termite treated) up to 2700 mm finish with
12 mm ply wood & above , till true ceiling finished
with both side one layer of 12.5mm thk Gypsum
-
board on either side with glass wool insulation 50
mm thick glass wool insulation of48 kg/ cum. density
neatly packed in tissue bags of various sizes and
shapes, bags shall be fully stitched all round with25
mm double leaf fold, sealing the glass wool fibre
fully.

The bags to be stuffed in the cavities of Gyp.


partitions from floor up to RCC slab above, cross
stitched from one side with GI frame work of partition
by 24 g GI wire to keep bags in position. UP
Twig/Rocklloyd make grade specified fixing to floor
& RCC roof with screw i/c provisions for grooves and
-
Fibber tape to be used for jointing and space/ cut-
outs for electrical sockets/switches and conduits etc.
as per detail drawings and specification and as
directed by Architect and duly fixed to floor/wall/RCC
roof with fasteners. Member placement to be worked
out as per grooves. complete as per drawing.

Note : - All vertical & Horizontal edges will be


covered 12mm MDF with paint finish . To receive
-
modular partition section & making pen tray cut outs
as directed by architects .
1.5 Glazed Glass Partition Sqm 10.00 4,650 46,500
Providing & fixing glass partition of 10mm toughened
glass with wooden frame work finish with melamine -
polish
1.6 Ceiling Sqm 12.00 775 9,300

24 of 48
Sr.No Description Unit Qty Rate Amount REMARKS

Providing and fixing Gypsum False Ceiling of India


Gypsum / La gyp make which includes G.I.
Perimeter Channels of size 0.55 mm thick ( having
One Flange of 20 mm. and another flange of 30 mm
and a web of 27 mm ) along with perimeter of
ceiling, screw fixed to brick wall / partition with the
help of Nylon sleeves and screws at 610mm centres.
Then suspending G.I. intermediate channels of size
45mm (0.9mm thick with 2 flanges of 15 mm each)
-
from the soffit at 1220 mm centres with ceiling angle
of width 25 mm X 10 mm X 0.55 mm thick fixed to
soffit with G.I. cleat and steel expansion fasteners.
Ceiling section of 0.55mm thick having knurled web
of 51.5 mm and 2 flanges of 26 mm each with lips
of 10.5 mm are then fixed to the intermediate
channel with the help of connecting clips and in
direction perpendicular to the intermediate channel
at 450 mm centres.

1.7 Fabric Panelling Sqm 12.88 2,800 36,064

FABRIC PANELING: Providing and fixing fabric


panelling fixed with fabric wrapped over UPVC Wall
tracts Gripper Pro stretch system with 12mm thick
MDF board with 3mm cushion backing fixed to the
hard wood framing / 12mm ply wood including all
-
hardware, fire retardant paint etc complete as per
design and drawing. Including the cost of 15mm x
15mm x 3mm SS Channel & 18mm Revel. Rate
inclusive of gripper (Basic Rate of fabric to be taken
as RS. 450 Sq.mtr)

1.8 MDF Cladding for Graphics / Paint Sqm 23.04 775 17,856

MDF PANNELING:-Providing and fixing 12mm thick.


MDF fixing on existing Partition / Frame work with -
groove S.S profile with necessary fixing.

1.9 Glass Panelling Sqm 6.00 3,500 21,000

GLASS PANELLING :- Providing and fixing 6mm


thick Saint Gobin Planilaque white glass fixed with
3M double sided foam tapes on 9 plywood backing
with laminated strips as per instruction of architects -
Including the cost of 15mm x 15mm x 3mm SS
Channel & 18mm Revel. Note: Do not include base
partition & framing for quote.

2.0 Modular Ceiling 0.5 NRC Sqm 8.00 950 7,600

GRID TILE CEILING: Providing & Fixing of


Armstrong Mineral Fibber Acoustical Suspended
Ceiling System with regular edge tiles should have
Humidity Resistance (RH) of 99%, NRC as mention
below, Light Reflectance >85%, Thermal
Conductivity k = 0.052- 0.057 w/m K, Colour White,
Fire Performance Class 0/Class1 (BS 476 Part 6&7)
in module size of 600 X 600 X 16 mm with Bio Block
coating on the face of the tile, suitable for Green
-
Building application, with Recycled content of
63%.The grid should be of “Armstrong” make with
silhouette with black groove - section flanges colour
white having rotary stitching on all T sections i.e. the
Main Runner, 1200 mm & 600 mm Cross Tees . The
T Sections have a Galvanizing of 120 grams per M2
& passed through 500 hrs of Salt test.The Tile & Grid
system used together should carry a 15 year
warrantee. Including Shadow line profile.

WALL PAPER :-Providing and fixing wall paper


(Vinyl wall covering) of approved make, on POP/
2.1 Gypboard surfaces with suitable adhesive as per Sqm 20.18 1,750 35,319
manufacturers specification.(Basic Rate of the
material to be taken as Rs. 150 / Sqft)
25 of 48
Sr.No Description Unit Qty Rate Amount REMARKS

2.2 Frost Film Sqm 3.73 1,150 4,285


FROSTED FILM (CRYSTAL QUALITY):- Providing
and fixing 3M / Avery / Birla scotchcal over glass
surface as approval of the Architect. (Height up to -
1200 , Only film surface area shall be measured
and paid)
M.D Cabin & 6 Pax Meeting Room & M.D Staff
K -
Area
Demolitions Ceiling / Partition / Floor / Panelling /
1.1 Sqm
Grid Ceiling

DEMOLITION OF EXISTING CEILING: Demolition


of Existing Ceiling / Partition / Floor / Panelling / Grid
Ceiling including all framework and sheet and
disposal of unserviceable material as directed to
municipal dumping ground. Rate should include -
safety precaution/measures taken to other
Lighting /AC/ or any other related fixtures while
carrying out the activites.Complete with all respect
as per Architect Instructions.

Gypsum Ceiling Sqm 22.00 180 3,960


Grid Ceiling Sqm 22.00 180 3,960
Screeding Sqm 21.00 225 4,725
1.2 Screeding Sqm 21.00 425 8,925

CEMENT CONCRETE SCREEDING:-Providing and


laying cement concrete for flooring to a maximum
75mm TO 100mm thick using cement concrete 1:2:4
(1cement :2Coarse sand :4graded stone aggregate
20mm and down gauge) for flooring bands and other
similar locations, tamped, spaded, toweled and top
finished neat, smooth with floating coat of cement as
-
directed laid in alternate panels of area not more
than 2 sqm and laid to water levels or proper slopes
as directed with necessary shuttering, hacking the
existing surface, curing etc. specifications. Rate are
inclusive of Junction box frame work & installation.
Complete with all respect as per detail drawing &
Architect Instructions.

1.3 Water Proofing Works Below Screeding Sqm 65.00 150 9,750

WATERPROOFING WORKS :- Providing and


applying water proofing coats slurry into existing slab
. Providing, supplying, mixing and applying cement
coats with water proofing compound of sunanda /
Roff make flexible water-proofing slurry to a
-
thickness of 1mm over the bottom , including
preparation of surface, finishing, curing etc. all
complete at different levels as specified by the
Architect as per manufacturer's specifications and as
directed.

1.5 Glass Partition Sqm 21.76 6,500 141,440


MODULAR PARTITION :- 10mm thk toughened
glass partition with 105 / 102mm x 25 / 18mm
Anodized Aluminium Frames-Providing & Fixing of
Aluminium single Glazed partition Jeb/Alloy
-
Equivalent using 105 / 102mm x 25 / 18mm thk
sections with required accessories and 1 layer of
10mm toughened glass for partition. The rate to
include the cost in complete
1.6 Ceiling Sqm 15.00 775 11,625

26 of 48
Sr.No Description Unit Qty Rate Amount REMARKS

Providing and fixing Gypsum False Ceiling of India


Gypsum / La gyp make which includes G.I.
Perimeter Channels of size 0.55 mm thick ( having
One Flange of 20 mm. and another flange of 30 mm
and a web of 27 mm ) along with perimeter of
ceiling, screw fixed to brick wall / partition with the
help of Nylon sleeves and screws at 610mm centres.
Then suspending G.I. intermediate channels of size
45mm (0.9mm thick with 2 flanges of 15 mm each)
-
from the soffit at 1220 mm centres with ceiling angle
of width 25 mm X 10 mm X 0.55 mm thick fixed to
soffit with G.I. cleat and steel expansion fasteners.
Ceiling section of 0.55mm thick having knurled web
of 51.5 mm and 2 flanges of 26 mm each with lips
of 10.5 mm are then fixed to the intermediate
channel with the help of connecting clips and in
direction perpendicular to the intermediate channel
at 450 mm centres.

12.5mm tapered edge Gypboard (conforming to IS


2095-1982) is then screw fixed to ceiling section with
25mm dry wall Philips screws at 230mm centres.
Screw fixing is done mechanically with drilling
machine with suitable attachment. Finally tapered
edges of the Gyp boards are to be jointed and
finished so as to have a flush look which includes
filling and finishing with jointing compound, paper -
tape etc complete as per the ASSESSMENT
practices of India Gypsum. Rate to be included all
kinds of profiles and cut outs required for light
fixtures, Speakers, Smoke detector, trap doors and
AC grill in the ceiling. The rate shall be inclusive of
Vertical Patties provided for fixing the gypsum ceiling
& also wherever height difference is there in ceiling.

1.7 Modular Ceiling 0.5 NRC Sqm 27.00 950 25,650

GRID TILE CEILING: Providing & Fixing of


Armstrong Mineral Fibber Acoustical Suspended
Ceiling System with regular edge tiles should have
Humidity Resistance (RH) of 99%, NRC as mention
below, Light Reflectance >85%, Thermal
Conductivity k = 0.052- 0.057 w/m K, Colour White,
Fire Performance Class 0/Class1 (BS 476 Part 6&7)
in module size of 600 X 600 X 16 mm with Bio Block
coating on the face of the tile, suitable for Green
-
Building application, with Recycled content of
63%.The grid should be of “Armstrong” make with
silhouette with black groove - section flanges colour
white having rotary stitching on all T sections i.e. the
Main Runner, 1200 mm & 600 mm Cross Tees . The
T Sections have a Galvanizing of 120 grams per M2
& passed through 500 hrs of Salt test.The Tile & Grid
system used together should carry a 15 year
warrantee. Including Shadow line profile.

1.8 Fabric Panelling Sqm 9.24 2,800 25,872

FABRIC PANELING: Providing and fixing fabric


panelling fixed with fabric wrapped over UPVC Wall
tracts Gripper Pro stretch system with 12mm thick
MDF board with 3mm cushion backing fixed to the
hard wood framing / 12mm ply wood including all
-
hardware, fire retardant paint etc complete as per
design and drawing. Including the cost of 15mm x
15mm x 3mm SS Channel & 18mm Revel. Rate
inclusive of gripper (Basic Rate of fabric to be taken
as RS. 450 Sq.mtr)

1.9 Glass Panelling Sqm 9.24 3,500 32,340

27 of 48
Sr.No Description Unit Qty Rate Amount REMARKS

GLASS PANELLING :- Providing and fixing 6mm


thick Saint Gobin Planilaque white glass fixed with
3M double sided foam tapes on 9 plywood backing
with laminated strips as per instruction of architects -
Including the cost of 15mm x 15mm x 3mm SS
Channel & 18mm Revel. Note: Do not include base
partition & framing for quote.

2.0 Designer Ceiling Sqm 30.00 1,050 31,500

Providing and fixing Gypsum False in Designer


Shape Ceiling of India Gypsum / La gyp make
which includes G.I. Perimeter Channels of size 0.55
mm thick ( having One Flange of 20 mm. and
another flange of 30 mm and a web of 27 mm )
along with perimeter of ceiling, screw fixed to brick
wall / partition with the help of Nylon sleeves and
screws at 610mm centres. Then suspending G.I.
intermediate channels of size 45mm (0.9mm thick
-
with 2 flanges of 15 mm each) from the soffit at
1220 mm centres with ceiling angle of width 25 mm
X 10 mm X 0.55 mm thick fixed to soffit with G.I.
cleat and steel expansion fasteners. Ceiling section
of 0.55mm thick having knurled web of 51.5 mm and
2 flanges of 26 mm each with lips of 10.5 mm are
then fixed to the intermediate channel with the help
of connecting clips and in direction perpendicular to
the intermediate channel at 450 mm centres.

12.5mm tapered edge Gypboard (conforming to IS


2095-1982) is then screw fixed to ceiling section with
25mm dry wall Philips screws at 230mm centres.
Screw fixing is done mechanically with drilling
machine with suitable attachment. Finally tapered
edges of the Gyp boards are to be jointed and
finished so as to have a flush look which includes
filling and finishing with jointing compound, paper -
tape etc complete as per the ASSESSMENT
practices of India Gypsum. Rate to be included all
kinds of profiles and cut outs required for light
fixtures, Speakers, Smoke detector, trap doors and
AC grill in the ceiling. The rate shall be inclusive of
Vertical Patties provided for fixing the gypsum ceiling
& also wherever height difference is there in ceiling.

2.1 Motorised Door Nos 1.00 145,000 145,000


Providing & fixing motorised doors of 12 mm
toughened glass with Dorma fitting with sensor with -
release switch on both side
2.2 Storages Modifications Sqm 7.92 7,500 59,400

Storage : Refurbishment of storage cabinet of with


New laminate/ Back Painted Glass schemes as per
architects instructions with finger groove shutter. -
NOTE: all hardware of ozone or equivalent. The rate
to include the cost to complete the entire item.

28 of 48
Sr.No Description Unit Qty Rate Amount REMARKS

Roller Blind:-Roller Tube Control with Oglives:Roller


Tube shall be of extruded Aluminium alloy 38-mm
O.D with a minimum wall thickness of 1.0mm duly
anodized for long life.Clutch:Clutch shall have a
carbon steel spring wrapped by means of a high
strength fibreglass reinforced polyester assembly to
transmit motion from driving to driven members of
clutch mechanism. Clutch shall operate bi-
directionally with the use of an endless S.S. beaded
2.3 chain. Clutch mechanism shall be crash proof, Sqm 113.40 1,250 141,750
prevent slippage and shall raise and lower smoothly
to any desired height. Clutch shall never need any
adjustment.Idler:Idler shall be of high strength
fibreglass reinforced polyster,consisting of an
outside sleeve and centre shaft. Sleeve shall provide
bearing surface for roller tube and rotate freely on
centre shaft, providing smooth, quiet and long
wearing operation. Basic Cost of Blinds -85 Rs/-
Per sqft including loading unloading and taxes

Brackets-Insert Type-Fit with Roller Tube: Brackets


shall be of made up of steel and powder coated to
give lasting finish. Brackets shall ensure overhead, -
side or face mounting with clutch assembly on either
end of the roller.

Round Bottom Rail: Bottom of the blind shall be


provided with aluminium tube with oglive ,powder
coated in a colour matching to the fabric. The fabric
shall be enclosed in the suitably created pocket
along with the tube. The tube shall be closed from
sides with end caps to ensure a neat look. Metal
Operating Ball Chain: The Control Unit will be
engraved to accommodate a Stainless Steel Ball
-
Chain with a Ball Pitch of no lesser than 6.5mm to
ensure an enduring operation along with an
aesthetic value. Roller Blind's Fabric: Composition:
42% Glass fibre +58 % Vinyl on Fibreglass,
Openness Factor:3%,Weight:535 G/ SQM,
Thickness: .55mm,Fire Classification:M1 ,FR, B-
1,care Instructions: Washable, Indoor Property:
Tested for Harmful Substances

WALL PAPER :-Providing and fixing wall paper


(Vinyl wall covering) of approved make, on POP/
2.4 Gypboard surfaces with suitable adhesive as per Sqm 23.29 1,750 40,753
manufacturers specification.(Basic Rate of the
material to be taken as Rs. 150 / Sqft)
2.5 Frost Film Sqm 10.63 1,150 12,220
FROSTED FILM (CRYSTAL QUALITY):- Providing
and fixing 3M / Avery / Birla scotchcal over glass
surface as approval of the Architect. (Height up to -
1200 , Only film surface area shall be measured
and paid)
L 2 Quite Room & 1 Nirvana Room -
Demolitions Ceiling / Partition / Floor / Panelling /
1.1 -
Grid Ceiling

DEMOLITION OF EXISTING CEILING: Demolition


of Existing Ceiling / Partition / Floor / Panelling / Grid
Ceiling including all framework and sheet and
disposal of unserviceable material as directed to
municipal dumping ground. Rate should include -
safety precaution/measures taken to other
Lighting /AC/ or any other related fixtures while
carrying out the activites.Complete with all respect
as per Architect Instructions.

Gypsum Ceiling Sqm 8.00 180 1,440


Grid Ceiling Sqm 9.00 180 1,620
Screeding Sqm 7.00 225 1,575

29 of 48
Sr.No Description Unit Qty Rate Amount REMARKS

1.2 Screeding Sqm 10.00 425 4,250

CEMENT CONCRETE SCREEDING:-Providing and


laying cement concrete for flooring to a maximum
75mm TO 100mm thick using cement concrete 1:2:4
(1cement :2Coarse sand :4graded stone aggregate
20mm and down gauge) for flooring bands and other
similar locations, tamped, spaded, toweled and top
finished neat, smooth with floating coat of cement as
-
directed laid in alternate panels of area not more
than 2 sqm and laid to water levels or proper slopes
as directed with necessary shuttering, hacking the
existing surface, curing etc. specifications. Rate are
inclusive of Junction box frame work & installation.
Complete with all respect as per detail drawing &
Architect Instructions.

1.3 Water Proofing Works Below Screeding Sqm 20.00 150 3,000

WATERPROOFING WORKS :- Providing and


applying water proofing coats slurry into existing slab
. Providing, supplying, mixing and applying cement
coats with water proofing compound of sunanda /
Roff make flexible water-proofing slurry to a
-
thickness of 1mm over the bottom , including
preparation of surface, finishing, curing etc. all
complete at different levels as specified by the
Architect as per manufacturer's specifications and as
directed.

1.4 Ceiling Sqm 15.00 775 11,625

Providing and fixing Gypsum False Ceiling of India


Gypsum / La gyp make which includes G.I.
Perimeter Channels of size 0.55 mm thick ( having
One Flange of 20 mm. and another flange of 30 mm
and a web of 27 mm ) along with perimeter of
ceiling, screw fixed to brick wall / partition with the
help of Nylon sleeves and screws at 610mm centres.
Then suspending G.I. intermediate channels of size
45mm (0.9mm thick with 2 flanges of 15 mm each)
-
from the soffit at 1220 mm centres with ceiling angle
of width 25 mm X 10 mm X 0.55 mm thick fixed to
soffit with G.I. cleat and steel expansion fasteners.
Ceiling section of 0.55mm thick having knurled web
of 51.5 mm and 2 flanges of 26 mm each with lips
of 10.5 mm are then fixed to the intermediate
channel with the help of connecting clips and in
direction perpendicular to the intermediate channel
at 450 mm centres.

12.5mm tapered edge Gypboard (conforming to IS


2095-1982) is then screw fixed to ceiling section with
25mm dry wall Philips screws at 230mm centres.
Screw fixing is done mechanically with drilling
machine with suitable attachment. Finally tapered
edges of the Gyp boards are to be jointed and
finished so as to have a flush look which includes
filling and finishing with jointing compound, paper -
tape etc complete as per the ASSESSMENT
practices of India Gypsum. Rate to be included all
kinds of profiles and cut outs required for light
fixtures, Speakers, Smoke detector, trap doors and
AC grill in the ceiling. The rate shall be inclusive of
Vertical Patties provided for fixing the gypsum ceiling
& also wherever height difference is there in ceiling.

1.5 Modular Ceiling 0.5 NRC Sqm 15.00 950 14,250

30 of 48
Sr.No Description Unit Qty Rate Amount REMARKS

GRID TILE CEILING: Providing & Fixing of


Armstrong Mineral Fibber Acoustical Suspended
Ceiling System with regular edge tiles should have
Humidity Resistance (RH) of 99%, NRC as mention
below, Light Reflectance >85%, Thermal
Conductivity k = 0.052- 0.057 w/m K, Colour White,
Fire Performance Class 0/Class1 (BS 476 Part 6&7)
in module size of 600 X 600 X 16 mm with Bio Block
coating on the face of the tile, suitable for Green
-
Building application, with Recycled content of
63%.The grid should be of “Armstrong” make with
silhouette with black groove - section flanges colour
white having rotary stitching on all T sections i.e. the
Main Runner, 1200 mm & 600 mm Cross Tees . The
T Sections have a Galvanizing of 120 grams per M2
& passed through 500 hrs of Salt test.The Tile & Grid
system used together should carry a 15 year
warrantee. Including Shadow line profile.

1.6 Fabric Panelling Sqm 8.00 2,800 22,400

FABRIC PANELING: Providing and fixing fabric


panelling fixed with fabric wrapped over UPVC Wall
tracts Gripper Pro stretch system with 12mm thick
MDF board with 3mm cushion backing fixed to the
-
hard wood framing / 12mm ply wood including all
hardware, fire retardant paint etc complete as per
design and drawing.Rate inclusive of gripper (Basic
Rate of fabric to be taken as RS. 450 Sq.mtr)

1.7 Glass Panelling Sqm 6.00 3,500 21,000


GLASS PANELLING :- Providing and fixing 6mm
thick Saint Gobin Planilaque white glass fixed with
3M double sided foam tapes on 9 plywood backing
-
with laminated strips as per instruction of architects.
Note: Do not include base partition & framing for
quote.
1.8 Glazed Partition Sqm 22.00 4,650 102,300
Providing & fixing glass partition of 10mm toughened
glass with wooden frame work finish with melamine -
polish
1.9 Door Refurbishment Nos 1.00 12,500 12,500
Refurbishment of existing doors as per detailed
drawings with repolishing of existing veneer in 3
-
coats of melamine polish both side all necessary
fittings.
2.0 Wooden Door Nos 1.00 15,500 15,500

Providing and fixing Single leaf Flush Door ,both


side approved Laminate finish & melamine polish
finish on edge with vision panel of 6mm thk glass
fixed on wooden beading , shutter fixed on Wooden
frame 105mm x 50mm with door jamb fitting as per
detail drawing . The doors will have best quality 4
-
Nos 4" long SS hinges, SS finished double legged
foot operated door stays, Polyvinyl door stopper
fixed to skirting, SS finish 25mm die 600mm high
handle (OZONE), lock, with OZONE make
Concealed Door closer shall be include in the cost of
door. Complete as per detail drawing .

2.1 Partition -Gypsum Sqm 17.00 1,500 25,500

31 of 48
Sr.No Description Unit Qty Rate Amount REMARKS

P1 FULL HEIGHT PARTITION: Providing and fixing


frame of Full height 75mm thick partition with GI
Framework @ 600 mm c/c both ways (Fire retardant
and anti-termite treated) up to 2700 mm finish with
12 mm ply wood & above , till true ceiling finished
with both side one layer of 12.5mm thk Gypsum
-
board on either side with glass wool insulation 50
mm thick glass wool insulation of48 kg/ cum. density
neatly packed in tissue bags of various sizes and
shapes, bags shall be fully stitched all round with25
mm double leaf fold, sealing the glass wool fibre
fully.

The bags to be stuffed in the cavities of Gyp.


partitions from floor up to RCC slab above, cross
stitched from one side with GI frame work of partition
by 24 g GI wire to keep bags in position. UP
Twig/Rocklloyd make grade specified fixing to floor
& RCC roof with screw i/c provisions for grooves and
-
Fibber tape to be used for jointing and space/ cut-
outs for electrical sockets/switches and conduits etc.
as per detail drawings and specification and as
directed by Architect and duly fixed to floor/wall/RCC
roof with fasteners. Member placement to be worked
out as per grooves. complete as per drawing.

Note : - All vertical & Horizontal edges will be


covered 12mm MDF with paint finish . To receive
-
modular partition section & making pen tray cut outs
as directed by architects .
2.2 Laminate Ledge Rmt 5.00 1,900 9,500
Providing & fixing laminate finish ledge made out of
-
25mm thick plywood with necessary fitting .
2.3 Repro Storage Unite Sqm 4.00 5,500 22,000

Providing and fixing Repro Counter in 19mm thick


Ply finished in 1.5 mm thick approved shade
laminate on all external surfaces & 1mm laminate
Internally, Including 25mm thick Ply Top with post
formed edge, intermediate shelves in 19mm thick
Double Side Laminated Ply, 100mm wide band
-
above Top in 19mm thick Ply finished in same
laminate and all the exposed edges to be finished
with edge banding. Rate to include of necessary nos
of locks, auto closing hinges for shutters, Slide
channels for drawers, approved handles, magnetic
ball-catch, Tower Bolt etc complete as directed

WALL PAPER :-Providing and fixing wall paper


(Vinyl wall covering) of approved make, on POP/
2.4 Gypboard surfaces with suitable adhesive as per Sqm 21.89 1,750 38,308
manufacturers specification.(Basic Rate of the
material to be taken as Rs. 150 / Sqft)
2.5 Frost Film Sqm 9.73 1,150 11,188
FROSTED FILM (CRYSTAL QUALITY):- Providing
and fixing 3M / Avery / Birla scotchcal over glass
surface as approval of the Architect. (Height up to -
1200 , Only film surface area shall be measured
and paid)
M Repro & Tea Coffee Machine
Demolitions Ceiling / Partition / Floor / Panelling /
1.1
Grid Ceiling

DEMOLITION OF EXISTING CEILING: Demolition


of Existing Ceiling / Partition / Floor / Panelling / Grid
Ceiling including all framework and sheet and
disposal of unserviceable material as directed to
municipal dumping ground. Rate should include
safety precaution/measures taken to other
Lighting /AC/ or any other related fixtures while
carrying out the activites.Complete with all respect
as per Architect Instructions.

32 of 48
Sr.No Description Unit Qty Rate Amount REMARKS

Gypsum Ceiling Sqm 5.00 180 900


Grid Ceiling Sqm 5.00 180 900
Screeding Sqm 8.00 225 1,800
1.2 Reprographic Counter Rmt 3.00 7,800 23,400

Providing and fixing Repro Counter in 19mm thick


Ply finished in 1.5 mm thick approved shade
laminate on all external surfaces & 1mm laminate
Internally, Including 25mm thick Ply Top with post
formed edge, intermediate shelves in 19mm thick
Double Side Laminated Ply, 100mm wide band
-
above Top in 19mm thick Ply finished in same
laminate and all the exposed edges to be finished
with edge banding. Rate to include of necessary nos
of locks, auto closing hinges for shutters, Slide
channels for drawers, approved handles, magnetic
ball-catch, Tower Bolt etc complete as directed

1.3 Over Head Storage Sqm 5.75 7,250 41,688

OVER HEAD STORAGE(600MM DEEP)LAMINATE


FINISH:-Providing & fixing over head Storage
cabinets 600 mm deep made out of 19mm
commercial board 1 mm thick laminate and
balancing laminate all inside adjustable laminated
-
shelves. Rate should be inclusive of necessary
Hardware- , Lock sets, self-closing hinges, spring
loaded shutter latch inside, all cabinet hardware as
approved & as /Architects approval. Hardware -
Hettich equivalent

1.4 Fabric Panelling Sqm 5.00 2,800 14,000

FABRIC PANELING: Providing and fixing fabric


panelling fixed with fabric wrapped over UPVC Wall
tracts Gripper Pro stretch system with 12mm thick
MDF board with 3mm cushion backing fixed to the
hard wood framing / 12mm ply wood including all
-
hardware, fire retardant paint etc complete as per
design and drawing. Including the cost of 15mm x
15mm x 3mm SS Channel & 18mm Revel. Rate
inclusive of gripper (Basic Rate of fabric to be taken
as RS. 450 Sq.mtr)

1.5 Partition -Gypsum Sqm RO 1,500

FULL HEIGHT PARTITION: Providing and fixing


frame of Full height 75mm thick partition with GI
Framework @ 600 mm c/c both ways (Fire retardant
and anti-termite treated) up to 2700 mm finish with
12 mm ply wood & above , till true ceiling finished
with both side one layer of 12.5mm thk Gypsum
-
board on either side with glass wool insulation 50
mm thick glass wool insulation of48 kg/ cum. density
neatly packed in tissue bags of various sizes and
shapes, bags shall be fully stitched all round with25
mm double leaf fold, sealing the glass wool fibre
fully.

The bags to be stuffed in the cavities of Gyp.


partitions from floor up to RCC slab above, cross
stitched from one side with GI frame work of partition
by 24 g GI wire to keep bags in position. UP
Twig/Rocklloyd make grade specified fixing to floor
& RCC roof with screw i/c provisions for grooves and
-
Fibber tape to be used for jointing and space/ cut-
outs for electrical sockets/switches and conduits etc.
as per detail drawings and specification and as
directed by Architect and duly fixed to floor/wall/RCC
roof with fasteners. Member placement to be worked
out as per grooves. complete as per drawing.

33 of 48
Sr.No Description Unit Qty Rate Amount REMARKS

Note : - All vertical & Horizontal edges will be


covered 12mm MDF with paint finish . To receive
-
modular partition section & making pen tray cut outs
as directed by architects .
1.6 Ceiling Sqm 16.00 775 12,400

Providing and fixing Gypsum False Ceiling of India


Gypsum / La gyp make which includes G.I.
Perimeter Channels of size 0.55 mm thick ( having
One Flange of 20 mm. and another flange of 30 mm
and a web of 27 mm ) along with perimeter of
ceiling, screw fixed to brick wall / partition with the
help of Nylon sleeves and screws at 610mm centres.
Then suspending G.I. intermediate channels of size
45mm (0.9mm thick with 2 flanges of 15 mm each)
-
from the soffit at 1220 mm centres with ceiling angle
of width 25 mm X 10 mm X 0.55 mm thick fixed to
soffit with G.I. cleat and steel expansion fasteners.
Ceiling section of 0.55mm thick having knurled web
of 51.5 mm and 2 flanges of 26 mm each with lips
of 10.5 mm are then fixed to the intermediate
channel with the help of connecting clips and in
direction perpendicular to the intermediate channel
at 450 mm centres.

12.5mm tapered edge Gypboard (conforming to IS


2095-1982) is then screw fixed to ceiling section with
25mm dry wall Philips screws at 230mm centres.
Screw fixing is done mechanically with drilling
machine with suitable attachment. Finally tapered
edges of the Gyp boards are to be jointed and
finished so as to have a flush look which includes
filling and finishing with jointing compound, paper -
tape etc complete as per the ASSESSMENT
practices of India Gypsum. Rate to be included all
kinds of profiles and cut outs required for light
fixtures, Speakers, Smoke detector, trap doors and
AC grill in the ceiling. The rate shall be inclusive of
Vertical Patties provided for fixing the gypsum ceiling
& also wherever height difference is there in ceiling.

N 2 Quite Room -
Demolitions Ceiling / Partition / Floor / Panelling /
1.1 Sqm -
Grid Ceiling

DEMOLITION OF EXISTING CEILING: Demolition


of Existing Ceiling / Partition / Floor / Panelling / Grid
Ceiling including all framework and sheet and
disposal of unserviceable material as directed to
municipal dumping ground. Rate should include -
safety precaution/measures taken to other
Lighting /AC/ or any other related fixtures while
carrying out the activites.Complete with all respect
as per Architect Instructions.

Gypsum Ceiling Sqm 5.00 180 900


Grid Ceiling Sqm 5.00 180 900
Screeding Sqm 8.00 225 1,800
1.2 Ceiling Sqm 8.00 775 6,200

34 of 48
Sr.No Description Unit Qty Rate Amount REMARKS

Providing and fixing Gypsum False Ceiling of India


Gypsum / La gyp make which includes G.I.
Perimeter Channels of size 0.55 mm thick ( having
One Flange of 20 mm. and another flange of 30 mm
and a web of 27 mm ) along with perimeter of
ceiling, screw fixed to brick wall / partition with the
help of Nylon sleeves and screws at 610mm centres.
Then suspending G.I. intermediate channels of size
45mm (0.9mm thick with 2 flanges of 15 mm each)
-
from the soffit at 1220 mm centres with ceiling angle
of width 25 mm X 10 mm X 0.55 mm thick fixed to
soffit with G.I. cleat and steel expansion fasteners.
Ceiling section of 0.55mm thick having knurled web
of 51.5 mm and 2 flanges of 26 mm each with lips
of 10.5 mm are then fixed to the intermediate
channel with the help of connecting clips and in
direction perpendicular to the intermediate channel
at 450 mm centres.

12.5mm tapered edge Gypboard (conforming to IS


2095-1982) is then screw fixed to ceiling section with
25mm dry wall Philips screws at 230mm centres.
Screw fixing is done mechanically with drilling
machine with suitable attachment. Finally tapered
edges of the Gyp boards are to be jointed and
finished so as to have a flush look which includes
filling and finishing with jointing compound, paper -
tape etc complete as per the ASSESSMENT
practices of India Gypsum. Rate to be included all
kinds of profiles and cut outs required for light
fixtures, Speakers, Smoke detector, trap doors and
AC grill in the ceiling. The rate shall be inclusive of
Vertical Patties provided for fixing the gypsum ceiling
& also wherever height difference is there in ceiling.

1.4 Modular Ceiling 0.5 NRC Sqm 3.24 950 3,078

GRID TILE CEILING: Providing & Fixing of


Armstrong Mineral Fibber Acoustical Suspended
Ceiling System with regular edge tiles should have
Humidity Resistance (RH) of 99%, NRC as mention
below, Light Reflectance >85%, Thermal
Conductivity k = 0.052- 0.057 w/m K, Colour White,
Fire Performance Class 0/Class1 (BS 476 Part 6&7)
in module size of 600 X 600 X 16 mm with Bio Block
coating on the face of the tile, suitable for Green
-
Building application, with Recycled content of
63%.The grid should be of “Armstrong” make with
silhouette with black groove - section flanges colour
white having rotary stitching on all T sections i.e. the
Main Runner, 1200 mm & 600 mm Cross Tees . The
T Sections have a Galvanizing of 120 grams per M2
& passed through 500 hrs of Salt test.The Tile & Grid
system used together should carry a 15 year
warrantee. Including Shadow line profile.

1.5 Fabric Panelling Sqm 3.00 2,800 8,400

FABRIC PANELING: Providing and fixing fabric


panelling fixed with fabric wrapped over UPVC Wall
tracts Gripper Pro stretch system with 12mm thick
MDF board with 3mm cushion backing fixed to the
hard wood framing / 12mm ply wood including all
-
hardware, fire retardant paint etc complete as per
design and drawing. Including the cost of 15mm x
15mm x 3mm SS Channel & 18mm Revel. Rate
inclusive of gripper (Basic Rate of fabric to be taken
as RS. 450 Sq.mtr)

1.6 Glass Panelling Sqm 4.00 3,500 14,000

35 of 48
Sr.No Description Unit Qty Rate Amount REMARKS

GLASS PANELLING :- Providing and fixing 6mm


thick Saint Gobin Planilaque white glass fixed with
3M double sided foam tapes on 9 plywood backing
with laminated strips as per instruction of architects -
Including the cost of 15mm x 15mm x 3mm SS
Channel & 18mm Revel. Note: Do not include base
partition & framing for quote.

1.7 Solid Partition Sqm 1.80 3,750 6,750 solid with laminate
Providing & fixing Low height partition with 50mm x
50mm wooden / Aluminium frame work with both
side 12mm ply wood skinning , finished with
-
laminate including all necessary cut out & grooves
with edge will be exposed edge will be teak wood
finish in melamine polish .
1.8 Glazed Partition Sqm 8.00 4,650 37,200
Providing & fixing glass partition of 10mm toughened
glass with wooden frame work finish with melamine -
polish
WALL PAPER :-Providing and fixing wall paper
(Vinyl wall covering) of approved make, on POP/
1.9 Gypboard surfaces with suitable adhesive as per Sqm 7.45 1,750 13,041
manufacturers specification.(Basic Rate of the
material to be taken as Rs. 150 / Sqft)
2.0 Frost Film Sqm 3.45 1,150 3,968
FROSTED FILM (CRYSTAL QUALITY):- Providing
and fixing 3M / Avery / Birla scotchcal over glass
surface as approval of the Architect. (Height up to -
1200 , Only film surface area shall be measured
and paid)
O 4P Meeting Room & 6P Meeting Room -
Demolitions Ceiling / Partition / Floor / Panelling /
1.1 Sqm
Grid Ceiling

DEMOLITION OF EXISTING CEILING: Demolition


of Existing Ceiling / Partition / Floor / Panelling / Grid
Ceiling including all framework and sheet and
disposal of unserviceable material as directed to
municipal dumping ground. Rate should include -
safety precaution/measures taken to other
Lighting /AC/ or any other related fixtures while
carrying out the activites.Complete with all respect
as per Architect Instructions.

Gypsum Ceiling Sqm 8.00 180 1,440


Grid Ceiling Sqm 9.00 180 1,620
Screeding Sqm 8.00 225 1,800
1.2 Screeding Sqm 10.00 425 4,250

CEMENT CONCRETE SCREEDING:-Providing and


laying cement concrete for flooring to a maximum
75mm TO 100mm thick using cement concrete 1:2:4
(1cement :2Coarse sand :4graded stone aggregate
20mm and down gauge) for flooring bands and other
similar locations, tamped, spaded, toweled and top
finished neat, smooth with floating coat of cement as
-
directed laid in alternate panels of area not more
than 2 sqm and laid to water levels or proper slopes
as directed with necessary shuttering, hacking the
existing surface, curing etc. specifications. Rate are
inclusive of Junction box frame work & installation.
Complete with all respect as per detail drawing &
Architect Instructions.

1.3 Water Proofing Works Below Screeding Sqm 10.00 150 1,500

36 of 48
Sr.No Description Unit Qty Rate Amount REMARKS

WATERPROOFING WORKS :- Providing and


applying water proofing coats slurry into existing slab
. Providing, supplying, mixing and applying cement
coats with water proofing compound of sunanda /
Roff make flexible water-proofing slurry to a
-
thickness of 1mm over the bottom , including
preparation of surface, finishing, curing etc. all
complete at different levels as specified by the
Architect as per manufacturer's specifications and as
directed.

1.4 Ceiling Sqm 15.00 775 11,625

Providing and fixing Gypsum False Ceiling of India


Gypsum / La gyp make which includes G.I.
Perimeter Channels of size 0.55 mm thick ( having
One Flange of 20 mm. and another flange of 30 mm
and a web of 27 mm ) along with perimeter of
ceiling, screw fixed to brick wall / partition with the
help of Nylon sleeves and screws at 610mm centres.
Then suspending G.I. intermediate channels of size
45mm (0.9mm thick with 2 flanges of 15 mm each)
-
from the soffit at 1220 mm centres with ceiling angle
of width 25 mm X 10 mm X 0.55 mm thick fixed to
soffit with G.I. cleat and steel expansion fasteners.
Ceiling section of 0.55mm thick having knurled web
of 51.5 mm and 2 flanges of 26 mm each with lips
of 10.5 mm are then fixed to the intermediate
channel with the help of connecting clips and in
direction perpendicular to the intermediate channel
at 450 mm centres.

12.5mm tapered edge Gypboard (conforming to IS


2095-1982) is then screw fixed to ceiling section with
25mm dry wall Philips screws at 230mm centres.
Screw fixing is done mechanically with drilling
machine with suitable attachment. Finally tapered
edges of the Gyp boards are to be jointed and
finished so as to have a flush look which includes
filling and finishing with jointing compound, paper -
tape etc complete as per the ASSESSMENT
practices of India Gypsum. Rate to be included all
kinds of profiles and cut outs required for light
fixtures, Speakers, Smoke detector, trap doors and
AC grill in the ceiling. The rate shall be inclusive of
Vertical Patties provided for fixing the gypsum ceiling
& also wherever height difference is there in ceiling.

1.5 Fabric Panelling Sqm 8.00 2,800 22,400

FABRIC PANELING: Providing and fixing fabric


panelling fixed with fabric wrapped over UPVC Wall
tracts Gripper Pro stretch system with 12mm thick
MDF board with 3mm cushion backing fixed to the
hard wood framing / 12mm ply wood including all
-
hardware, fire retardant paint etc complete as per
design and drawing. Including the cost of 15mm x
15mm x 3mm SS Channel & 18mm Revel. Rate
inclusive of gripper (Basic Rate of fabric to be taken
as RS. 450 Sq.mtr)

1.6 Glass Panelling Sqm 6.00 3,500 21,000

GLASS PANELLING :- Providing and fixing 6mm


thick Saint Gobin Planilaque white glass fixed with
3M double sided foam tapes on 9 plywood backing
with laminated strips as per instruction of architects -
Including the cost of 15mm x 15mm x 3mm SS
Channel & 18mm Revel. Note: Do not include base
partition & framing for quote.

1.7 Door Refurbishment Nos 2.00 12,500 25,000

37 of 48
Sr.No Description Unit Qty Rate Amount REMARKS

Refurbishment of existing doors as per detailed


drawings with Door bedding & modification with door
fame including repolishing of existing veneer in 2 -
coats of melamine polish both side all necessary
fittings.
1.8 Modular Ceiling 0.5 NRC 12.00 950 11,400

GRID TILE CEILING: Providing & Fixing of


Armstrong Mineral Fibber Acoustical Suspended
Ceiling System with regular edge tiles should have
Humidity Resistance (RH) of 99%, NRC as mention
below, Light Reflectance >85%, Thermal
Conductivity k = 0.052- 0.057 w/m K, Colour White,
Fire Performance Class 0/Class1 (BS 476 Part 6&7)
in module size of 600 X 600 X 16 mm with Bio Block
coating on the face of the tile, suitable for Green
-
Building application, with Recycled content of
63%.The grid should be of “Armstrong” make with
silhouette with black groove - section flanges colour
white having rotary stitching on all T sections i.e. the
Main Runner, 1200 mm & 600 mm Cross Tees . The
T Sections have a Galvanizing of 120 grams per M2
& passed through 500 hrs of Salt test.The Tile & Grid
system used together should carry a 15 year
warrantee. Including Shadow line profile.

WALL PAPER :-Providing and fixing wall paper


(Vinyl wall covering) of approved make, on POP/
1.9 Gypboard surfaces with suitable adhesive as per Sqm 18.94 1,750 33,146
manufacturers specification.(Basic Rate of the
material to be taken as Rs. 150 / Sqft)
2.0 Frost Film Sqm 6.90 1,150 7,935
FROSTED FILM (CRYSTAL QUALITY):- Providing
and fixing 3M / Avery / Birla scotchcal over glass
surface as approval of the Architect. (Height up to -
1200 , Only film surface area shall be measured
and paid)
2P Quite Room , 3P Quite Room & 10P Meeting
P -
Room
Demolitions Ceiling / Partition / Floor / Panelling /
1.1 Sqm
Grid Ceiling

DEMOLITION OF EXISTING CEILING: Demolition


of Existing Ceiling / Partition / Floor / Panelling / Grid
Ceiling including all framework and sheet and
disposal of unserviceable material as directed to
municipal dumping ground. Rate should include -
safety precaution/measures taken to other
Lighting /AC/ or any other related fixtures while
carrying out the activites.Complete with all respect
as per Architect Instructions.

Gypsum Ceiling Sqm 8.00 180 1,440


Grid Ceiling Sqm 7.00 180 1,260
Screeding Sqm 25.00 225 5,625
1.2 Screeding Sqm 25.00 425 10,625

CEMENT CONCRETE SCREEDING:-Providing and


laying cement concrete for flooring to a maximum
75mm TO 100mm thick using cement concrete 1:2:4
(1cement :2Coarse sand :4graded stone aggregate
20mm and down gauge) for flooring bands and other
similar locations, tamped, spaded, toweled and top
finished neat, smooth with floating coat of cement as
-
directed laid in alternate panels of area not more
than 2 sqm and laid to water levels or proper slopes
as directed with necessary shuttering, hacking the
existing surface, curing etc. specifications. Rate are
inclusive of Junction box frame work & installation.
Complete with all respect as per detail drawing &
Architect Instructions.

38 of 48
Sr.No Description Unit Qty Rate Amount REMARKS

1.3 Water Proofing Works Below Screeding Sqm 25.00 150 3,750

WATERPROOFING WORKS :- Providing and


applying water proofing coats slurry into existing slab
. Providing, supplying, mixing and applying cement
coats with water proofing compound of sunanda /
Roff make flexible water-proofing slurry to a
-
thickness of 1mm over the bottom , including
preparation of surface, finishing, curing etc. all
complete at different levels as specified by the
Architect as per manufacturer's specifications and as
directed.

1.4 Ceiling Sqm 30.00 775 23,250

Providing and fixing Gypsum False Ceiling of India


Gypsum / La gyp make which includes G.I.
Perimeter Channels of size 0.55 mm thick ( having
One Flange of 20 mm. and another flange of 30 mm
and a web of 27 mm ) along with perimeter of
ceiling, screw fixed to brick wall / partition with the
help of Nylon sleeves and screws at 610mm centres.
Then suspending G.I. intermediate channels of size
45mm (0.9mm thick with 2 flanges of 15 mm each)
-
from the soffit at 1220 mm centres with ceiling angle
of width 25 mm X 10 mm X 0.55 mm thick fixed to
soffit with G.I. cleat and steel expansion fasteners.
Ceiling section of 0.55mm thick having knurled web
of 51.5 mm and 2 flanges of 26 mm each with lips
of 10.5 mm are then fixed to the intermediate
channel with the help of connecting clips and in
direction perpendicular to the intermediate channel
at 450 mm centres.

12.5mm tapered edge Gypboard (conforming to IS


2095-1982) is then screw fixed to ceiling section with
25mm dry wall Philips screws at 230mm centres.
Screw fixing is done mechanically with drilling
machine with suitable attachment. Finally tapered
edges of the Gyp boards are to be jointed and
finished so as to have a flush look which includes
filling and finishing with jointing compound, paper -
tape etc complete as per the ASSESSMENT
practices of India Gypsum. Rate to be included all
kinds of profiles and cut outs required for light
fixtures, Speakers, Smoke detector, trap doors and
AC grill in the ceiling. The rate shall be inclusive of
Vertical Patties provided for fixing the gypsum ceiling
& also wherever height difference is there in ceiling.

1.5 Modular Ceiling 0.5 NRC Sqm 20.00 950 19,000

GRID TILE CEILING: Providing & Fixing of


Armstrong Mineral Fibber Acoustical Suspended
Ceiling System with regular edge tiles should have
Humidity Resistance (RH) of 99%, NRC as mention
below, Light Reflectance >85%, Thermal
Conductivity k = 0.052- 0.057 w/m K, Colour White,
Fire Performance Class 0/Class1 (BS 476 Part 6&7)
in module size of 600 X 600 X 16 mm with Bio Block
coating on the face of the tile, suitable for Green
-
Building application, with Recycled content of
63%.The grid should be of “Armstrong” make with
silhouette with black groove - section flanges colour
white having rotary stitching on all T sections i.e. the
Main Runner, 1200 mm & 600 mm Cross Tees . The
T Sections have a Galvanizing of 120 grams per M2
& passed through 500 hrs of Salt test.The Tile & Grid
system used together should carry a 15 year
warrantee. Including Shadow line profile.

1.6 Fabric Panelling Sqm 19.68 2,800 55,104

39 of 48
Sr.No Description Unit Qty Rate Amount REMARKS

FABRIC PANELING: Providing and fixing fabric


panelling fixed with fabric wrapped over UPVC Wall
tracts Gripper Pro stretch system with 12mm thick
MDF board with 3mm cushion backing fixed to the
hard wood framing / 12mm ply wood including all
-
hardware, fire retardant paint etc complete as per
design and drawing. Including the cost of 15mm x
15mm x 3mm SS Channel & 18mm Revel. Rate
inclusive of gripper (Basic Rate of fabric to be taken
as RS. 450 Sq.mtr)

1.7 Glass Panelling Sqm 6.00 3,500 21,000

GLASS PANELLING :- Providing and fixing 6mm


thick Saint Gobin Planilaque white glass fixed with
3M double sided foam tapes on 9 plywood backing
with laminated strips as per instruction of architects -
Including the cost of 15mm x 15mm x 3mm SS
Channel & 18mm Revel. Note: Do not include base
partition & framing for quote.

1.8 Door Refurbishment Nos 4.00 12,500 50,000


Refurbishment of existing doors as per detailed
drawings with repolishing of existing veneer in 3
-
coats of melamine polish both side all necessary
fittings.
WALL PAPER :-Providing and fixing wall paper
(Vinyl wall covering) of approved make, on POP/
1.9 Gypboard surfaces with suitable adhesive as per Sqm 34.47 2,000 68,931
manufacturers specification.(Basic Rate of the
material to be taken as Rs. 150 / Sqft)
2.0 Frost Film Sqm 14.49 1,150 16,664
FROSTED FILM (CRYSTAL QUALITY):- Providing
and fixing 3M / Avery / Birla scotchcal over glass
surface as approval of the Architect. (Height up to -
1200 , Only film surface area shall be measured
and paid)
2nd Floor -
Q Café & 6 P Meeting Room -
Demolitions Ceiling / Partition / Floor / Panelling /
1.1 Sqm
Grid Ceiling

DEMOLITION OF EXISTING CEILING: Demolition


of Existing Ceiling / Partition / Floor / Panelling / Grid
Ceiling including all framework and sheet and
disposal of unserviceable material as directed to
municipal dumping ground. Rate should include -
safety precaution/measures taken to other
Lighting /AC/ or any other related fixtures while
carrying out the activites.Complete with all respect
as per Architect Instructions.

Gypsum Ceiling Sqm 75.00 180 13,500


Partation Sqm 50.00 225 11,250
Screeding Sqm 125.00 225 28,125
1.2 Screeding Sqm 125.00 425 53,125

CEMENT CONCRETE SCREEDING:-Providing and


laying cement concrete for flooring to a maximum
75mm TO 100mm thick using cement concrete 1:2:4
(1cement :2Coarse sand :4graded stone aggregate
20mm and down gauge) for flooring bands and other
similar locations, tamped, spaded, toweled and top
finished neat, smooth with floating coat of cement as
-
directed laid in alternate panels of area not more
than 2 sqm and laid to water levels or proper slopes
as directed with necessary shuttering, hacking the
existing surface, curing etc. specifications. Rate are
inclusive of Junction box frame work & installation.
Complete with all respect as per detail drawing &
Architect Instructions.

1.3 Water Proofing Works Below Screeding Sqm 125.00 150 18,750
40 of 48
Sr.No Description Unit Qty Rate Amount REMARKS

WATERPROOFING WORKS :- Providing and


applying water proofing coats slurry into existing slab
. Providing, supplying, mixing and applying cement
coats with water proofing compound of sunanda /
Roff make flexible water-proofing slurry to a
-
thickness of 1mm over the bottom , including
preparation of surface, finishing, curing etc. all
complete at different levels as specified by the
Architect as per manufacturer's specifications and as
directed.

1.4 Solid Partition -gypsum Sqm 107.52 1,500 161,280

P1 FULL HEIGHT PARTITION: Providing and fixing


frame of Full height 75mm thick partition with GI
Framework @ 600 mm c/c both ways (Fire retardant
and anti-termite treated) up to 2700 mm finish with
12 mm ply wood & above , till true ceiling finished
with both side one layer of 12.5mm thk Gypsum
-
board on either side with glass wool insulation 50
mm thick glass wool insulation of48 kg/ cum. density
neatly packed in tissue bags of various sizes and
shapes, bags shall be fully stitched all round with25
mm double leaf fold, sealing the glass wool fibre
fully.

The bags to be stuffed in the cavities of Gyp.


partitions from floor up to RCC slab above, cross
stitched from one side with GI frame work of partition
by 24 g GI wire to keep bags in position. UP
Twig/Rocklloyd make grade specified fixing to floor
& RCC roof with screw i/c provisions for grooves and
-
Fibber tape to be used for jointing and space/ cut-
outs for electrical sockets/switches and conduits etc.
as per detail drawings and specification and as
directed by Architect and duly fixed to floor/wall/RCC
roof with fasteners. Member placement to be worked
out as per grooves. complete as per drawing.

Note : - All vertical & Horizontal edges will be


covered 12mm MDF with paint finish . To receive
-
modular partition section & making pen tray cut outs
as directed by architects .
1.5 Glazed Partition Sqm 15.00 4,650 69,750
Providing & fixing glass partition of 10mm toughened
glass with wooden frame work finish with melamine -
polish
1.6 Doors Nos 4.00 15,500 62,000

(900X2400):Providing and fixing Single leaf


Flush Door ,both side approved Laminate finish
& melamine polish finish on edge with vision
panel of 6mm thk glass fixed on wooden beading ,
shutter fixed on teak wood frame work of "105mm x
50mm with door jamb fitting as per manufacture
specification. The doors will have best quality 4 Nos -
4" long SS hinges, SS finished double legged foot
operated door stays, Polyvinyl door stopper fixed to
skirting, SS finish 32mm die 1800mm high handle
(HETTICH/OZONE) , lock, with Dorma make
Concealed Door closer shall be include in the cost of
door. Complete as per detail drawing .

1.7 Doctor Room Door Nos 1.00 14,500 14,500


Same as above but in without vision panel -
1.7A Refurbishment of existing door Nos 1.00 12,500 12,500
Refurbishment of existing doors as per detailed
drawings with repolishing of existing veneer in 3
-
coats of melamine polish both side all necessary
fittings.
1.8 Doctor Table Nos 1.00 12,000 12,000
Providing & fixing counter up to 500mm deep with
-
single line drawer finished with laminate.
1.9 Massage chair Nos 1.00 8,500 8,500
41 of 48
Sr.No Description Unit Qty Rate Amount REMARKS

2.0 Working Bench Rmt 5.00 8,500 42,500

BENCH SEATING (LAMINATE FINISH WITH


LEATHER SEATS):Providing and fixing bench
seating of width 450 mm with corner round , with
laminate finish & approved leather seats. Primary
structure to be in 19 mm thick block board with
necessary framework and approved hardware's -
.External structure to be in laminate finish. Under
structure under the cushion to be in laminate.
Cushion to be 85 mm thick high density foam
finished in leather with approved stitching. The rate
to include all the cost to complete the entire item.

2.1 Fabric Panelling Sqm 10.00 2,800 28,000

FABRIC PANELING: Providing and fixing fabric


panelling fixed with fabric wrapped over UPVC Wall
tracts Gripper Pro stretch system with 12mm thick
MDF board with 3mm cushion backing fixed to the
hard wood framing / 12mm ply wood including all
-
hardware, fire retardant paint etc complete as per
design and drawing. Including the cost of 15mm x
15mm x 3mm SS Channel & 18mm Revel. Rate
inclusive of gripper (Basic Rate of fabric to be taken
as RS. 450 Sq.mtr)

2.2 Glass Panelling Sqm 3.00 3,500 10,500

GLASS PANELLING :- Providing and fixing 6mm


thick Saint Gobin Planilaque white glass fixed with
3M double sided foam tapes on 9 plywood backing
with laminated strips as per instruction of architects -
Including the cost of 15mm x 15mm x 3mm SS
Channel & 18mm Revel. Note: Do not include base
partition & framing for quote.

2.3 Planter Box Sqm 2.00 4,750 9,500

Providing and fixing of 6mm thick laminated finish to


be made in hardwood framing. The 25 mm
commercial board to be fixed with 1mm thick
-
laminate finished under structure as approved
design. The rate to include the pebbles of the width
of 1200 mm wide as directed by Architect

2.4 Café Ceiling Sqm 129.60 1,150 149,040

Providing and fixing Gypsum False in Designer


Shape Ceiling of India Gypsum / La gyp make
which includes G.I. Perimeter Channels of size 0.55
mm thick ( having One Flange of 20 mm. and
another flange of 30 mm and a web of 27 mm )
along with perimeter of ceiling, screw fixed to brick
wall / partition with the help of Nylon sleeves and
screws at 610mm centres. Then suspending G.I.
intermediate channels of size 45mm (0.9mm thick
-
with 2 flanges of 15 mm each) from the soffit at
1220 mm centres with ceiling angle of width 25 mm
X 10 mm X 0.55 mm thick fixed to soffit with G.I.
cleat and steel expansion fasteners. Ceiling section
of 0.55mm thick having knurled web of 51.5 mm and
2 flanges of 26 mm each with lips of 10.5 mm are
then fixed to the intermediate channel with the help
of connecting clips and in direction perpendicular to
the intermediate channel at 450 mm centres.

42 of 48
Sr.No Description Unit Qty Rate Amount REMARKS

12.5mm tapered edge Gypboard (conforming to IS


2095-1982) is then screw fixed to ceiling section with
25mm dry wall Philips screws at 230mm centres.
Screw fixing is done mechanically with drilling
machine with suitable attachment. Finally tapered
edges of the Gyp boards are to be jointed and
finished so as to have a flush look which includes
filling and finishing with jointing compound, paper -
tape etc complete as per the ASSESSMENT
practices of India Gypsum. Rate to be included all
kinds of profiles and cut outs required for light
fixtures, Speakers, Smoke detector, trap doors and
AC grill in the ceiling. The rate shall be inclusive of
Vertical Patties provided for fixing the gypsum ceiling
& also wherever height difference is there in ceiling.

2.5 Café Flooring Sqm 125.00 2,950 368,750

LAMINATED WOODEN FLOORING - Providing and


laying laminated wooden flooring in the form of
planks of size 12 / 10mm thick, laid on IPS base
-
with 2mm form backing including edge profile/
beading wherever required all complete as per
Architects Instructions (Basic Rate 180 INR /SQ.FT)

2.6 Library Storage Sqm 9.60 7,500 72,000


Providing & fixing library storage unite with laminate
-
finish
Semi Glazed Entrance Partition near café entrance
2.8 Sqm 1.00 5,100 5,100
door
Providing & fixing glass partition of 10mm toughened
glass with wooden frame work finish with melamine -
polish
2.9 Modular Ceiling 0.5 NRC Sqm 25.00 950 23,750

GRID TILE CEILING: Providing & Fixing of


Armstrong Mineral Fibber Acoustical Suspended
Ceiling System with regular edge tiles should have
Humidity Resistance (RH) of 99%, NRC as mention
below, Light Reflectance >85%, Thermal
Conductivity k = 0.052- 0.057 w/m K, Colour White,
Fire Performance Class 0/Class1 (BS 476 Part 6&7)
in module size of 600 X 600 X 16 mm with Bio Block
coating on the face of the tile, suitable for Green
-
Building application, with Recycled content of
63%.The grid should be of “Armstrong” make with
silhouette with black groove - section flanges colour
white having rotary stitching on all T sections i.e. the
Main Runner, 1200 mm & 600 mm Cross Tees . The
T Sections have a Galvanizing of 120 grams per M2
& passed through 500 hrs of Salt test.The Tile & Grid
system used together should carry a 15 year
warrantee. Including Shadow line profile.

WALL PAPER :-Providing and fixing wall paper


(Vinyl wall covering) of approved make, on POP/
3.0 Gypboard surfaces with suitable adhesive as per Sqm 40.37 1,750 70,639
manufacturers specification.(Basic Rate of the
material to be taken as Rs. 150 / Sqft)
3.1 Frost Film Sqm 3.04 1,150 3,491
FROSTED FILM (CRYSTAL QUALITY):- Providing
and fixing 3M / Avery / Birla scotchcal over glass
surface as approval of the Architect. (Height up to -
1200 , Only film surface area shall be measured
and paid)
R 22 Pax Meeting Room & 2 P Quite Room -
Demolitions Ceiling / Partition / Floor / Panelling /
1.1 Sqm
Grid Ceiling

43 of 48
Sr.No Description Unit Qty Rate Amount REMARKS

DEMOLITION OF EXISTING CEILING: Demolition


of Existing ceiling including all framework and sheet
and disposal of unserviceable material as directed to
municipal dumping ground. Rate should include
-
safety precaution/measures taken to other
Lighting /AC/ or any other related fixtures while
carrying out the activites.Complete with all respect
as per Architect Instructions.

Gypsum Ceiling Sqm 75.00 180 13,500


Partation Sqm 45.00 225 10,125
Screeding Sqm 55.00 225 12,375
1.2 Screeding Sqm 55.00 425 23,375

CEMENT CONCRETE SCREEDING:-Providing and


laying cement concrete for flooring to a maximum
75mm TO 100mm thick using cement concrete 1:2:4
(1cement :2Coarse sand :4graded stone aggregate
20mm and down gauge) for flooring bands and other
similar locations, tamped, spaded, toweled and top
finished neat, smooth with floating coat of cement as
-
directed laid in alternate panels of area not more
than 2 sqm and laid to water levels or proper slopes
as directed with necessary shuttering, hacking the
existing surface, curing etc. specifications. Rate are
inclusive of Junction box frame work & installation.
Complete with all respect as per detail drawing &
Architect Instructions.

1.3 Water Proofing Works Below Screeding Sqm 55.00 150 8,250

WATERPROOFING WORKS :- Providing and


applying water proofing coats slurry into existing slab
. Providing, supplying, mixing and applying cement
coats with water proofing compound of sunanda /
Roff make flexible water-proofing slurry to a
-
thickness of 1mm over the bottom , including
preparation of surface, finishing, curing etc. all
complete at different levels as specified by the
Architect as per manufacturer's specifications and as
directed.

1.4 Sliding Folding Partition Sqm 20.00 27,000 540,000

SLIDING FOLDING PARTITION (MALROX


MAKE) :-Supply, fabrication and installing exclusive
extruded aluminium top track – for holding the
partition panels; with necessary rectangular / flat
sandwich plates as required, with special extruded
aluminium profiles – on both ends; with stiffeners
(horizontal) so as to form a rigid non-deflecting
-
framework – duly fitted with extending rubber
gaskets (seal) at the top & at the bottom level; filling
the framework with fibre glass. Each framework will
be fitted with a SHEET OF TECH-SOUND 50 and
finally laid on with DECOBOARD (12mm) Panels
and supplied in a LAMINATE FINISHED
CONDITION.

1.5 Fabric Panelling Sqm 10.00 2,800 28,000

FABRIC PANELING: Providing and fixing fabric


panelling fixed with fabric wrapped over UPVC Wall
tracts Gripper Pro stretch system with 12mm thick
MDF board with 3mm cushion backing fixed to the
hard wood framing / 12mm ply wood including all
-
hardware, fire retardant paint etc complete as per
design and drawing. Including the cost of 15mm x
15mm x 3mm SS Channel & 18mm Revel. Rate
inclusive of gripper (Basic Rate of fabric to be taken
as RS. 450 Sq.mtr)

1.6 Glass Panelling Sqm 2.00 3,500 7,000

44 of 48
Sr.No Description Unit Qty Rate Amount REMARKS

GLASS PANELLING :- Providing and fixing 6mm


thick Saint Gobin Planilaque white glass fixed with
3M double sided foam tapes on 9 plywood backing
with laminated strips as per instruction of architects -
Including the cost of 15mm x 15mm x 3mm SS
Channel & 18mm Revel. Note: Do not include base
partition & framing for quote.

1.7 Glazed Partition Sqm 17.40 4,650 80,910


Providing & fixing glass partition of 10mm toughened
glass with wooden frame work finish with melamine -
polish
1.8 Door Refurbishment Nos 3.00 12,500 37,500
Refurbishment of existing doors as per detailed
drawings with repolishing of existing veneer in 3
-
coats of melamine polish both side all necessary
fittings.
1.9 Console Unit Rmt 5.40 7,500 40,500

Providing & fixing console unite of 450mm deep


-
finish with laminate including all necessary hardware

Roller Blind:-Roller Tube Control with Oglives:Roller


Tube shall be of extruded Aluminium alloy 38-mm
O.D with a minimum wall thickness of 1.0mm duly
anodized for long life.Clutch:Clutch shall have a
carbon steel spring wrapped by means of a high
strength fibreglass reinforced polyester assembly to
transmit motion from driving to driven members of
clutch mechanism. Clutch shall operate bi-
directionally with the use of an endless S.S. beaded
2.0 Sqm 27.00 1,250 33,750
chain. Clutch mechanism shall be crash proof,
prevent slippage and shall raise and lower smoothly
to any desired height. Clutch shall never need any
adjustment.Idler:Idler shall be of high strength
fibreglass reinforced polyster,consisting of an
outside sleeve and centre shaft. Sleeve shall provide
bearing surface for roller tube and rotate freely on
centre shaft, providing smooth, quiet and long
wearing operation.

Brackets-Insert Type-Fit with Roller Tube: Brackets


shall be of made up of steel and powder coated to
give lasting finish. Brackets shall ensure overhead, -
side or face mounting with clutch assembly on either
end of the roller.

Round Bottom Rail: Bottom of the blind shall be


provided with aluminium tube with oglive ,powder
coated in a colour matching to the fabric. The fabric
shall be enclosed in the suitably created pocket
along with the tube. The tube shall be closed from
sides with end caps to ensure a neat look. Metal
-
Operating Ball Chain: The Control Unit will be
engraved to accommodate a Stainless Steel Ball
Chain with a Ball Pitch of no lesser than 6.5mm to
ensure an enduring operation along with an
aesthetic value. Roller Blind's Fabric: Composition:
100% balck out

S 4P,3P & 6P Meeting Room -


Demolitions Ceiling / Partition / Floor / Panelling /
1.1 Sqm
Grid Ceiling

DEMOLITION OF EXISTING CEILING: Demolition


of Existing ceiling including all framework and sheet
and disposal of unserviceable material as directed to
municipal dumping ground. Rate should include
-
safety precaution/measures taken to other
Lighting /AC/ or any other related fixtures while
carrying out the activites.Complete with all respect
as per Architect Instructions.

45 of 48
Sr.No Description Unit Qty Rate Amount REMARKS

Gypsum Ceiling Sqm 10.00 180 1,800


Partation Sqm 10.00 225 2,250
Screeding Sqm 55.00 225 12,375
1.2 Screeding Sqm 55.00 425 23,375

CEMENT CONCRETE SCREEDING:-Providing and


laying cement concrete for flooring to a maximum
75mm TO 100mm thick using cement concrete 1:2:4
(1cement :2Coarse sand :4graded stone aggregate
20mm and down gauge) for flooring bands and other
similar locations, tamped, spaded, toweled and top
finished neat, smooth with floating coat of cement as
-
directed laid in alternate panels of area not more
than 2 sqm and laid to water levels or proper slopes
as directed with necessary shuttering, hacking the
existing surface, curing etc. specifications. Rate are
inclusive of Junction box frame work & installation.
Complete with all respect as per detail drawing &
Architect Instructions.

1.3 Water Proofing Works Below Screeding Sqm 55.00 150 8,250

WATERPROOFING WORKS :- Providing and


applying water proofing coats slurry into existing slab
. Providing, supplying, mixing and applying cement
coats with water proofing compound of sunanda /
Roff make flexible water-proofing slurry to a
-
thickness of 1mm over the bottom , including
preparation of surface, finishing, curing etc. all
complete at different levels as specified by the
Architect as per manufacturer's specifications and as
directed.

1.4 Ceiling Sqm 15.00 775 11,625

Providing and fixing Gypsum False Ceiling of India


Gypsum / La gyp make which includes G.I.
Perimeter Channels of size 0.55 mm thick ( having
One Flange of 20 mm. and another flange of 30 mm
and a web of 27 mm ) along with perimeter of
ceiling, screw fixed to brick wall / partition with the
help of Nylon sleeves and screws at 610mm centres.
Then suspending G.I. intermediate channels of size
45mm (0.9mm thick with 2 flanges of 15 mm each)
-
from the soffit at 1220 mm centres with ceiling angle
of width 25 mm X 10 mm X 0.55 mm thick fixed to
soffit with G.I. cleat and steel expansion fasteners.
Ceiling section of 0.55mm thick having knurled web
of 51.5 mm and 2 flanges of 26 mm each with lips
of 10.5 mm are then fixed to the intermediate
channel with the help of connecting clips and in
direction perpendicular to the intermediate channel
at 450 mm centres.

12.5mm tapered edge Gypboard (conforming to IS


2095-1982) is then screw fixed to ceiling section with
25mm dry wall Philips screws at 230mm centres.
Screw fixing is done mechanically with drilling
machine with suitable attachment. Finally tapered
edges of the Gyp boards are to be jointed and
finished so as to have a flush look which includes
filling and finishing with jointing compound, paper -
tape etc complete as per the ASSESSMENT
practices of India Gypsum. Rate to be included all
kinds of profiles and cut outs required for light
fixtures, Speakers, Smoke detector, trap doors and
AC grill in the ceiling. The rate shall be inclusive of
Vertical Patties provided for fixing the gypsum ceiling
& also wherever height difference is there in ceiling.

1.5 Modular Ceiling 0.5 NRC Sqm 20.00 950 19,000

46 of 48
Sr.No Description Unit Qty Rate Amount REMARKS

GRID TILE CEILING: Providing & Fixing of


Armstrong Mineral Fibber Acoustical Suspended
Ceiling System with regular edge tiles should have
Humidity Resistance (RH) of 99%, NRC as mention
below, Light Reflectance >85%, Thermal
Conductivity k = 0.052- 0.057 w/m K, Colour White,
Fire Performance Class 0/Class1 (BS 476 Part 6&7)
in module size of 600 X 600 X 16 mm with Bio Block
coating on the face of the tile, suitable for Green
-
Building application, with Recycled content of
63%.The grid should be of “Armstrong” make with
silhouette with black groove - section flanges colour
white having rotary stitching on all T sections i.e. the
Main Runner, 1200 mm & 600 mm Cross Tees . The
T Sections have a Galvanizing of 120 grams per M2
& passed through 500 hrs of Salt test.The Tile & Grid
system used together should carry a 15 year
warrantee. Including Shadow line profile.

1.6 Fabric Panelling Sqm 17.00 2,800 47,600

FABRIC PANELING: Providing and fixing fabric


panelling fixed with fabric wrapped over UPVC Wall
tracts Gripper Pro stretch system with 12mm thick
MDF board with 3mm cushion backing fixed to the
-
hard wood framing / 12mm ply wood including all
hardware, fire retardant paint etc complete as per
design and drawing. Rate inclusive of gripper (Basic
Rate of fabric to be taken as RS. 450 Sq.mtr)

1.7 Glass Panelling Sqm 7.00 3,500 24,500


GLASS PANELLING :- Providing and fixing 6mm
thick Saint Gobin Planilaque white glass fixed with
3M double sided foam tapes on 9 plywood backing
-
with laminated strips as per instruction of architects .
Note: Do not include base partition & framing for
quote.
1.8 Door Refurbishment Nos 4.00 12,500 50,000
Refurbishment of existing doors as per detailed
drawings with repolishing of existing veneer in 3
-
coats of melamine polish both side all necessary
fittings.
WALL PAPER :-Providing and fixing wall paper
(Vinyl wall covering) of approved make, on POP/
1.9 Gypboard surfaces with suitable adhesive as per Sqm 29.81 2,000 59,616
manufacturers specification.(Basic Rate of the
material to be taken as Rs. 150 / Sqft)
1.10 Frost Film Sqm 13.25 1,150 15,235
FROSTED FILM (CRYSTAL QUALITY):- Providing
and fixing 3M / Avery / Birla scotchcal over glass
surface as approval of the Architect. (Height up to -
1200 , Only film surface area shall be measured
and paid)
Staff Area -
Demolitions Ceiling / Partition / Floor / Panelling /
1.1 Sqm
Grid Ceiling

DEMOLITION OF EXISTING CEILING: Demolition


of Existing ceiling including all framework and sheet
and disposal of unserviceable material as directed to
municipal dumping ground. Rate should include
-
safety precaution/measures taken to other
Lighting /AC/ or any other related fixtures while
carrying out the activites.Complete with all respect
as per Architect Instructions.

Gypsum Ceiling Sqm 75.00 180 13,500


Partation Sqm 75.00 225 16,875
Screeding Sqm 350.00 225 78,750
Screeding & Raceway Filling due to orientation
1.2 Sqm 350.00 425 148,750
changes

47 of 48
Sr.No Description Unit Qty Rate Amount REMARKS

CEMENT CONCRETE SCREEDING:-Providing and


laying cement concrete for flooring to a maximum
75mm TO 100mm thick using cement concrete 1:2:4
(1cement :2Coarse sand :4graded stone aggregate
20mm and down gauge) for flooring bands and other
similar locations, tamped, spaded, toweled and top
finished neat, smooth with floating coat of cement as
-
directed laid in alternate panels of area not more
than 2 sqm and laid to water levels or proper slopes
as directed with necessary shuttering, hacking the
existing surface, curing etc. specifications. Rate are
inclusive of Junction box frame work & installation.
Complete with all respect as per detail drawing &
Architect Instructions.

1.3 Water Proofing Works Below Screeding Sqm 200.00 150 30,000

WATERPROOFING WORKS :- Providing and


applying water proofing coats slurry into existing slab
. Providing, supplying, mixing and applying cement
coats with water proofing compound of sunanda /
Roff make flexible water-proofing slurry to a
-
thickness of 1mm over the bottom , including
preparation of surface, finishing, curing etc. all
complete at different levels as specified by the
Architect as per manufacturer's specifications and as
directed.

1.4 Paintings :- Walls & Ceiling Sqm 5,000.00 200 1,000,000


PLASTIC EMULTION PAINT:- Providing and
applying on Gypsum Ceiling including surface
-
preparation, primer coats, levelling Patti and
minimum 3 coats of brush and roller finish.
1.5 Storage Sqm 110.00 7,500 825,000

STORAGE(600MM DEEP)LAMINATE FINISH:-


Providing & fixing over head Storage cabinets 600
mm deep made out of 19mm commercial board 1
mm thick laminate and balancing laminate all inside
adjustable laminated shelves. Rate should be -
inclusive of necessary Hardware- , Lock sets, self-
closing hinges, spring loaded shutter latch inside, all
cabinet hardware as approved & as /Architects
approval. Hardware - Hettich equivalent

1.6 Quiet Room Ledge Rmt RO 4,250


Providing & fixing laminate finish ledge made out of
-
25mm thick plywood with necessary fitting .
-
1.7 50mm Axiom Profile for Meeting Room Ceiling Rmt 20.00 550 11,000
-
65mm single side gypsum Partition for Barricading
1.8 Sqm 500.00 550 275,000
workspace.
-
1.9 Removing of existing Carpet Sqm 2,322.56 52 120,773
-
Dismantling of existing Furniture Like , Meeting Table
2.0 Nos -
, Cabinet , Loose furniture
-
2.1 Temporary door Nos 10.00 3,500 35,000
-
2.2 Truck Load for rabit shifting Nos 40.00 3,500 140,000

TOTAL AMOUNT OF CIVIL & JOINERY 9,884,800

48 of 48