CENTRIFUGAL PUMP DATA SHEET E
V
1 ITEM NO. PU-4901A/B NO. REQ'D 2(TWO) REV. DATE PREP BY CHD BY APD BY
2 SERVICE CONDENSATE TRANS. PUMP REQ'N NO. 0 '10. 6. 30 S.G.LIM
3 JOB NO. 30469 SPEC. NO. 1
4 CLIENT LG CHEM, LTD LOCATION NAJUU, KOREA 2
5 PLANT 3
6 PUMP MFR SERIAL NO.
7 NOTE. INDICATES INFORMATION TO BE COMPLETED BY PURCHASER. BY MANUFACTURER
8 OPERATING CONDITION PERFORMANCE
9 LIQUID STEAM COND. CAP.@PTm 3 / hr NOR. RATED 40 PROPOSAL CURVE NO.
10 DISCH. PRESS. Kg/cm2 G 5.00 rpm NPSHR m
11 PT ℃ NOR 110 MAX. SUC. PRESS. Kg/cm 2 G RATED 0 EFF. % BHP RATED kW
2
12 SP.GR. @ PT 0.96 DIFF. PRESS. Kg/cm 5.00 MAX. BHP RATED IMP. kW
13 VAP. PRES. @PT KGA 1.45 DIFF. HEAD. M 50 MAX. HEAD RATED IMP. m
14 VIS. @PT. ssu cp 1 NPSHA. M 0.8 LIQ. HP kW MIN. CONTINUOUS FLOW RATE m3/hr
15 CORR./EROS. CAUSED BY ROTATING ( VIEWED FROM CPLG END )
16 CONSTRUCTION SHOP TESTS
17 NOZZLES SIZE RATING FACING LOCATION NON-WIT. PREF. WIT. PERF.
18 SUCTION ANSI 150# RF NON-WIT. HYDRO. WIT. HYDRO
19 DISCHARGE ANSI 150# RF NPSH REQUIRED WIT. NPSH
20 CASE MOUNT. CENTERLINE FOOT BRACKET VERT. (TYPE) SHOP INSPECTION
21 SPLIT. AXIAL RAD. TYPE VOLUTE SGL DBL DIFFUSER DISMANT. & INSP. AFTER TEST
22 PRESS. MAX. ALLOW. 15 Kg/cm2G 180 ℃ HYDRO TEST Kg/cm2G OTHERS
23 CONNECT. VENT DRAIN GAGE
24 SUCTION. SINGLE DOUBLE NO OF STAGE
25 IMPELLER DIA. RATED MM MAX. mm TYPE.
26 MOUNT BETWEEN BRGS OVERHUNG MATERIALS
27 BEARING TYPE RADIAL THRUST PUMP. CASE / TRIM CLASS
28 LUBE. RING OIL FLOOD OIL MIST FLINGER PRESSURE CASE SUS304
29 COUPLING MFR MODEL IMPELLER SUS304
30 DRIVER HALF MTD BY PUMP MFR DRIVER MFR PURCHASER WEARINGS
31 PACKING : MFR & TYPE SIZE & NO. OF RINGS SHAFT / SLEEVE
32 MECH. SEAL : MFR & MODEL API CLASS. CODE 21 BASEPLATE
33 MFR CODE
34 AUXILIARY PIPING SITE CONDITIONS
35 C.W. PIPE PLAN CU. S.S. TUBING PIPE TEMP. MAX. 35 ℃
36 TOTAL COOLING WATER REQ'D, m 3/hr SIGHT F.I REQ'D MIN. -10 ℃
37 PACKING COOLING INJECTION REQ'D TOTAL m3/hr Kg/cm2G REL. HUM. %
38 SEAL FLUSH PIPE PLAN CU. S.S. TUBING PIPE ALTITUDE ABOVE MEAN SEA LEVEL M
39 EXTERNAL SEAL FLUSH FLUID 3
m /hr Kg/cm2G ○ INDOOR
40 AUX. SEAL PLAN CU. S.S. TUBING PIPE V OUTDOOR
41 AUX. SEAL QUENCH FLUID ○ HEATED
42 MOTOR DRIVER ○ UNHEATED
43 kW RPM FRAME VOLT / PHASE / HZ 440 / 3 / 60 ○ SUN
44 MFR BEARINGS LUBE. AREA CLASSIFICATION : IEC ZONE 2
45 TYPE F ENC. ExeII T3 INSUL. TEMP. RISE ℃ B OTHER
46 MOUNTED BY
47 TURBINE DRIVER APPROX. WEIGHT
48 kW RPM PUMP & BASE Kg
49 MFR TYPE MOTOR Kg
50 MOUNTED BY TURB. Kg
51 REMARKS :
52 1. MAX. NOISE LEVEL FOR PUMP WITH MOTOR SHALL BE 85 dB(A) AT IM.