You are on page 1of 1

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

A A
B B
FFL of pump
house Distribution Main Steel
#10 @ 150 C/C #12 @ 150 C/C
1. DO NOT SCALE THE DRAWING, REFER
C FIGURED DIMENSION.
C
Pockets 2. ANY DESCRIPANCIES OR OMISSION OR
CHANGES SHALL BE BROUGHT TO NOTICE
PRIOR TO EXECUTION.
3. SBC OF SOIL IS ASSUMED AS 20 T/SQM
4. FOUNDATION IS DESIGNED FOR MACHINE
150mm PCC LOADING ONLY.
D D
150mm Sand filling 6. CONCRETE GRADE USED IS M20 UNLESS
OTHERWISE MENTIONED.
7. ALL STEEL EXCEPT 6mmØ IS TOR STEEL( ) OF
GRADE Fe 415 N/mmSq.
8. LAPPING OR ANCHORAGE LENGTH
FOR a) BEAM AND SLAB = 60 TIMES DIA
b) COLUMN = 50 TIMES DIA
E E
9. CLEAR COVER TO REINFORCEMENT
SECTION a) FOOTING = 50 MM
b) COLUMN = 40 MM
c) BEAM = 25 MM
d) SLAB =15 MM
10. DESIGN OF CENTERING, SHUTTERING
Main Steel & CONCRETE MIX IS THE RESPONSIBILITY
F OF CONTRACTOR. F
#12 @ 150 C/C
REV NO. DESCRIPTION DATE
G G
H ORIENTATION: H
6 nos pockets for M22
foundation bolt pocket
size 90sq at top &130sq
I at bottom Project:
I
Distribution
#10 @ 150 C/C Client:
Reviewed Approved
Structural Consultants :
J ARCHITECTURAL & STRUCTURAL CONSULTANTS
J
BRIDGE ENGINEERS & PMC
1st FLOOR, ANAND COMPLEX,
Opp. KOTAMBRI COLLEGE, VIDYANAGAR,
HUBLI - 580 031
PH:(0836) 2277437 (O), FAX: (0836) 2277437
email : galagali.associates@gmail.com
150mm thk PCC ARCHITECTS :
PLAN
K K
Contractor:
DIMENSIONS OF 60hp PUMP FOUNDATION TYPICAL RCC DETAILS OF 60hp PUMP FOUNDATION Designed Vishal
Project
Incharge
Approved AMG Checked
L L
Drawn Shraddha.M Checked
Scale NTS
Date of Issue 19-05-2016
Project No. 2350
M Soft copy ref Prithvi-G:\user files\vishal\IOCL\PUMP FOUNDATION M
Discipline: STRUCTURAL
RCC DETAILS OF 60hp PUMP FOUNDATION Title: RCC DETAILS OF 60hp PUMP FOUNDATION
Drawing No.
N GA/STR/IOCL/60hpPF-01 N
PUMP FOUNDATION AT IOCL DEPOT, RAYAPUR, DHARWAD Note: This drawing is the Property of M/s Galagali Associates, HUBLI.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20