You are on page 1of 52

QUESTION BANK 1

PEC (51-100)

START
51. Which of the following
A. 3.5 𝑚𝑚2
conductor sizes has the highest
resistance?
B. 8.0 𝑚𝑚2

C. 2.0 𝑚𝑚2

D. 5.5 𝑚𝑚2

NEXT
52. A device or equipment which
A. Rosette
is suspended from overload
either by means of a flexible cord
carrying the current, or B. Pendant
otherwise.
C. Fixture

D. Air terminal

NEXT
53. In the schedule of loads for
A. Type of motor
motor circuits, which of the
following is NOT included?
B. Manufacturer of motor

C. Motor as numbered in the


power layout

D. Number of phases

NEXT
54. What is the allowable
A. 45 A
ampacity of THW insulated
copper comductor with an area
of 8.0 mm2 and exposed to an B. 20 A
ambient temperature of 300 C.
C. 30 A

D. 60 A

NEXT
55. Which one is a standard
A. 140 A
rating of an inverse time CB?

B. 130 A

C. 120 A

D. 110 A

NEXT
56. The term ampere-hour is
A. Converters
associated with which of the
following?
B. Transformers

C. Electromagnets

D. Storage Cells

NEXT
57. Electrical equipment may best
A. Wooden plug
be mounted on a concrete wall
by using one of the following.
Which one is this? B. Expansion bolt

C. Load plug

D. Plastic plug

NEXT
58. Before starting any
A. Building permit
installation work, alteration,
repair or extension on any
electrical system, what type of B. Working permit
permit is needed?
C. Electrical permit

D. Mayor’s permit

NEXT
59. Above ground tanks A. The metal roof shall have a
containing liquids at atmospheric minimum thickness of 4.8 mm
pressure are considered to be
B. The roof shall be welded,
protected against lighting if the
bolted or riveted to the shell
following requirements are meet.
C. All pipes entering the tank shall be
Which one?
metallically connected to the tank at the
point of entrance

D. All of these

NEXT
60. When computing the service
A. 80 %
load, more than three fixed
appliances are computed with a
demand factor of ______ of the B. 65 %
nameplate rating.
C. 70 %

D. 75 %

NEXT
61. if the project is extensive and
A.7
requires more time for checking
and for computations of fees, the
issuance of the electrical permit B. 6
need not to be issued
immediately. However, the delay
C. 5
shall not be longer than how
many working days?
D. 8

NEXT
62. Splices in ground conductors
A. 900 N
shall be as few as practicable and
shall be attached so as to
withstand a pull test of ______. B. 880 N

C. 800 N

D. 890 N

NEXT
63. Locations which are
A. Class I
hazardous because of the
presence of combustible dust.
B. Class II

C. Class III

D. Class IV

NEXT
64. If there are three wires of 150
A. 200 mm
mm2 connected to one terminal
entering a cabinet or a
switchboard, the bending space B. 300 mm
at each terminal shall NOT be less
than ______, provided the
C. 400 mm
conductors do not enter or leave
the enclosure through the wall
opposite its terminals. D. 250 mm

NEXT
65. For an ambient temperature
A. 20 A
of 30oC, a THW insulated copper
conductor with a cross sectional
area of 3.5 mm2 and buried B. 40 A
underground has the following
ampacity. Which one is correct?
C. 15 A

D. 30 A

NEXT
66. All extended parts located
A. 1,500 mm
within _______ of the lightning
protection system shall be
bonded thereto. B. 1,600 mm

C. 1,800 mm

D. 2,000 mm

NEXT
67. Operation at substantially
A. Continuous duty
constant load for an indefinitely
long time.
B. Intermittent duty

C. Periodic duty

D. Short time duty

NEXT
68. Transformer exceeding 112.5
A. 400 mm
kVa shall not be located within
______ from combustible
materials of the building. B. 300 mm

C. 200 mm

D. 500 mm

NEXT
69. Electrodes of iron or steel
A. 6.4 mm
plates shall be at least ______ in
thickness.
B. 5.8 mm

C. 6.0 mm

D. 6.2 mm

NEXT
70. Advisory rules in the PEC are
A. Will
characterized by the use of what
word?
B. Would

C. Shall

D. Should

NEXT
71. The frame of the vehicle- A. The vehicle of the generator
mounted generator shall be is bonded to the vehicle frame
permitted to serve as the
B. The generator supplies only
grounding electrode for a system equipment located on the vehicle
supplied by a generator located
on the vehicle under which of the C. The non-current carrying metal parts of equipment
and the equipment grounding conductor terminals of
following conditions? the receptacles are bonded to the generator frame

D. All of these

NEXT
72. What is the minimum
A. 600 V
insulation level (in volts) for the
neutral conductors of a solidly
grounded system? B. 300 V

C. 500 V

D. 1,000 V

NEXT
73. No boxes shall have an
A. 15 mm
internal depth of less than how
many millimeters
B. 10 mm

C. 12 mm

D. 14 mm

NEXT
74. Branch circuits are classified
A. Voltage across it
according to which of the
following?
B. Load being served
C. Power consumed Setting of
the overcurrent device

D. Setting of the overcurrent


device

NEXT
75. The following copper
A. 19-strand conductor
conductors have the same cross
sectional area but are made up of
different number of strands. B. Single solid conductor
Which one has the least
resistance to AC current?
C. 7-strand conductor

D. 37-strand conductor

NEXT
76. An appliance, which is
A. Permanent appliance
fastened or otherwise, secured at
a specific location.
B. Stationary appliance

C. Portable appliance

D. Fixed appliance

NEXT
77. What is the minimum
A. 25, 000 ohms
insulation resistance required for
circuits rated from 2001 to 400 A?
B. 50, 000 ohms

C. 100, 000 ohms

D. 12, 500 ohms

NEXT
78. A device capable to drawing
A. Air terminal
lightning discharge to it in
preference to vulnerable parts of
the protected area. B. Lightning trap

C. Ground mat

D. Ground terminal

NEXT
79. Light fixtures suspended from
A. Chain is grounded
the ceiling by chains should be
wired so that the ______.
B. Wires help to support the
fixture
C. Wires will not touch the
chains
D. Wires do not support the
fixture

NEXT
80. Which of the following
A. RA 7920
Republic Act number refers to the
new Electrical Engineering Law?
B. RA 8450

C. RA 8710

D. RA 1840

NEXT
81. Cable tray shall NOT be used
A. Hoistways
in which of the following
applications?
B. Dry locations

C. Industrial establishments

D. All of these

NEXT
82. A heavy duty lamp holder
A. 450 W
shall have a rating no less than
how many watts?
B. 500 W

C. 600 W

D. 660 W

NEXT
83. In rigid metal conduit wiring,
A. 2,500 mm
conduits shall be supported at
least every
B. 3,500 mm

C. 3,000 mm

D. 2,000 mm

NEXT
84. Conductors used in open
A. 3,000 mm
wiring method within ______
from the floor shall be considered
exposed to physical damage. B. 2,500 mm

C. 2,000 mm

D. 1,800 mm

NEXT
85. Conductors normally used to
A. Aluminum
carry current shall be made of
_____ unless otherwise provided
B. Copper
in the PEC. B. Copper

C. Steel

D. Silver

NEXT
86. What is the maximum
A. 150 mm
electrical trade size of
intermediate conduit?
B. 125 mm

C. 200 mm

D. 100 mm

NEXT
87. The Philippine Electrical Code
A. Advisory
is intended for what type of
applications by government
bodies exercising legal jurisdiction B. Mandatory
over electrical installation?
C. Optional

D. Professional

NEXT
88. Individual branch circuits
A. 20 A
using type FCC (flat conductor
cable) shall have ratings not
exceeding how much amperes? B. 30 A

C. 15 A

D. 40 A

NEXT
89. Equipment installation in
A. 4
hazardous locations must be
tested and approved for use
according to the classification of B. 3
the hazards involved. These are
divided into _____ groups.
C. 7

D. 6

NEXT
90. Aerial cable under non-
A. 60 mm
metallic extensions shall have a
clearance not less than how
much from steel structure B. 30 mm
members or other conductive
materials?
C. 50 mm

D. 40 mm

NEXT
91. For all land-based electrical
A. Department of Energy
installation under the scope of
the Philippine Electrical Code,
where should an electrical permit B. Office of the City Engineer
be filed?
C. Office of the Mayor

D. Local Building Office

NEXT
92. Compliance with the
A. I, II and III
provisions of PEC will result in
____.
B. I and II
I. freedom from hazard
II. good electrical service C. II only
III. an efficient system
D. I only

NEXT
93. In an auxiliary gutter, how
A. 26 mm
much is the minimum clearance
between bare current carrying
metal parts and any metal surface B. 24 mm
at the gutter?
C. 13 mm

D. 12 mm

NEXT
94. Heating elements of cable
A. 200 mm
shall be separated at least by how
much from the edge of outlet
boxes and junction boxes? B. 100 mm

C. 150 mm

D. 300 mm

NEXT
95. Auxiliary gutters shall not
A. 36
contain more than _______
current carrying conductors at
any cross section. B. 32

C. 30

D. 24

NEXT
96. As a rule, no overcurrent
A. Stranded
device shall be connected in
series with any conductor that is
_____. B. Current carrying

C. Closed

D. Intentionally grounded

NEXT
97. Which of the following wires
A. Type THWN
is applicable for underground
service entrance conductors?
B. Type UF

C. Type MI

D. Type USE

NEXT
98. For the purpose of lightning
A. 23 m
protection, a high rise building is
a building with a height over how
much? B. 50 m

C. 20 m

D. 15 m

NEXT
99. What type of electrical
A. TW
conductors has a trade name,
moisture resistant
thermosplastic? B. THW

C. THWN

D. All of these

NEXT
100. A device used for the
A. Rheostat box
purpose of minimizing
irregularities in the flow of
welding currents. B. Grounding transformer

C. Reactor

D. Inverter

NEXT