You are on page 1of 4

VPD-130

Quick Start Guide


Version 1.0.0

 E-mail: service@icpdas.com
FTP: ftp://ftp.icpdas.com/pub/cd/touchpad/

Wirings
 Data+ and Data- are signal pins in the RS-485 network
 VDC/GND are power (+12 ~ 48 VDC) and ground
 USB is used to update firmware from PC

Install HMIWorks
VPD-130 Quick Start, version 1.0.0. Last Revised: April 2011 Page: 1

Copyright © 2011 ICP DAS Co., Ltd. All Rights Reserved.  E-mail: service@icpdas.com
Install TouchPAD USB Driver
1. Using USB cable to connect to the TouchPAD Device. Rotary Switch
set to “9” and you can see the screen of update mode.

2. The Found New Hardware Wizard pops up thereafter, and select


 “No, not this time” (and press “Next”)
 “Install from a list or specific location (Advanced)”
 “Include this location in the search”. Browse for driver files:
The default path for the driver is:
C:\ICPDAS\HMIWorks_Standard\Tools\USB_windows_drivers,
where “C:\ICPDAS\HMIWorks_Standard\” is the installation path.

Download through USB


Plug the USB cable into the TouchPAD to download.

Start
After resetting ,
In back of below is seen.
TouchPAD
Rotary Switch = 9

Reset

Download the Run  Run (F9)


program
by Run  Run In back of
Rotary Switch = 0 TouchPAD

Reset

End

VPD-130 Quick Start, version 1.0.0. Last Revised: April 2011 Page: 2

Copyright © 2011 ICP DAS Co., Ltd. All Rights Reserved.  E-mail: service@icpdas.com
Integrate with I/O modules
In this example, we use VPD-130 to control an I-7066, the
7-channel photo-MOS relay output module of ICP DAS. First, put
I-7066 in the same RS-485 network of VPD-130 and configure
I-7066 with DCON Utility.

0. Configure I-7066 Using DCON Utility


Download DCON Utility and its user manual on
ftp://ftp.icpdas.com/pub/cd/8000cd/napdos/driver/dcon_utility/
Then configure I-7066 with DCON Utility. Mainly, Address(Net ID),
Baudrate, Databit, Parity, Stopbit should be set.

1. Create a New Project


Go to the menu: File  New…, and here we choose
programming type as [2] Ladder Program.

2. Register Device
Create a new connection first in the Workspace.
And then press F3 key to evoke the “Devices” window to register
I-7066.

VPD-130 Quick Start, version 1.0.0. Last Revised: April 2011 Page: 3

Copyright © 2011 ICP DAS Co., Ltd. All Rights Reserved.  E-mail: service@icpdas.com
Then select the picture which represents the tag. Drag and drop
the tag that is corresponding to the DO0 of I-7066 to the frame
design space. On the frame design space, the picture you just
pick is now on the frame.

3. Be sure to install USB driver on PC first

4. Compile and Download to Run


After connecting to TouchPAD, press F9 to run
(or Run  Run). Refer to previous section,
“Download through USB”, for details.
As the following figure shows, pressing the
button changes the output of channel 0 of the
I-7066.

VPD-130 Quick Start, version 1.0.0. Last Revised: April 2011 Page: 4

Copyright © 2011 ICP DAS Co., Ltd. All Rights Reserved.  E-mail: service@icpdas.com

You might also like