Table of Contents
A. Analog System F. Power Supplies
1 FireNET Plus 1127 - Analog Addressable FACP 63 FN-300/400/600/1024-ULX Auxiliary Power Supply/Charger
2 FireNET 4127 - Analog Addressable Fire Alarm Control Panel 64 FN-642/842/1042-ULADA - NAC Power Extenders
3 FireNET 4127 - Analog Addressable Fire Alarm Control Panel 65 PE-6/10SN - Power Extenders
w/Plexiglass Window
4 FN-LCD-N - LCD Network Annunciator
5 FN-LCD-S - LCD Serial Annunciator G. Voice Evacuation Systems
6 FireNET Graphix Software Package
7 FNP-LED - FireNET Plus Graphix LED Display 66 FNV-MP & FNV-DP Voice Evacuation System
8 FN-DAC - Digital Alarm Communicator 67 FNV - VoiceNET Fire Phone Equipment
9 DCP-AMS - Addressable Manual Pull Stations 68 EVAX 25 - Conventional Voice Evacuation System
10 FNP-1127-SLC - Single SLC Loop Expander 69 EVAX 50 - Conventional Voice Evacuation System
11 FN-4127-SLC - Dual SLC Loop Expander 70 EVAX 100 - Conventional Voice Evacuation System
12 FN-4127-IO - 16 Channel Input/Output Board 71 EVAX 150 / 200 - Conventional Voice Evacuation System
13 FN-4127-NIC - Network Interface Card
14 FN-CTM - City Tie Module H. Notification Appliances
15 FN-ACC-R/C Battery Enclosure
16 Serial Cables - S187/X187/P187/V187 72 HE Series - Selectable Candela Evacuation Signals
73 HC Series - Selectable Ceiling Mount Strobe and Horn Strobe
B. Analog Series 74 HGOE-R / HGOE-W - Outdoor Enclosure
75 HBLP, HSB & HCSB Series - Back Box
17 ALK-V - Photoelectric Smoke Sensor 76 HAVSM - Synchronization Control Module
18 ALN-V - Photoelectric Smoke Sensor 77 HSSPKCLP Series - Ceiling Mount Speaker/Strobe
19 ATJ-EA - Heat Sensor 78 HSSPKWLP Series - Wall Mount Speaker/Strobe
20 ACA-V - Multi Criteria Sensor 79 HX93 Series Mini Horn
21 Analog Sensor Bases 80 WHE Series Weatherproof Evacuation Signals
22 ASB - Analog Sounder Base 81 HEP Series - Colored Lens Expander Plate Strobe
23 SCI-B4 / B6 - Short Circuit Isolator Analog Sensor Bases 82 B6-24 / B10-24 / BB-WP - Fire Alarm Bells & Weatherproof Back Box
24 DH-99A/AR - Analog Duct Detector
25 SOM-A/-AI - Class A Supervised Output Module I. FireNET / FirePro Xtinguish
26 SOM-R - Supervised Output Module
27 FRCME-P - Fast Response Contact Monitoring Module w/ Pigtails 83 FireNET/FirePro Xtinguish Series Aerosol Generators
28 FRCME-M - Fast Response Contact Monitoring Module 84 HCVR-3 - Conventional Releasing Panel
29 FRCMA/-I - Fast Response Contact Monitoring Module 85 HCVR-AB - Ancillary Board
30 SCI - Short Circuit Isolator 86 HCVR-SDU - Status Display Unit
31 R2M-L/LI/H/HI- Dual Relay Module 87 HCVR-AS - Extinguishant Abort Switch
32 DIMM - Dual Input Monitoring Module 88 HCVR-SQA - Sequential Activator
33 CZM - Conventional Zone Module 89 HPS-DAK-SR - Manual Pull Station for Fire Suppression Release
34 RAI-LED - Remote Alarm Indicator 90 HCVR-DS - Disable Switch
91 SOM-R-DS - Disable Switch
C. Conventional System
J. FireNET Vapor
35 HCA - Fire Alarm Control Panel
36 HCP-1008E - Fire Alarm Control Panel 92 FireNET Vapor VPR-1 Detector
37 HRA-1000 - Remote Annunciators 93 FireNET Vapor VPR-1P Detector
38 HPS - Manual Pull Stations 94 FireNET Vapor VPR-4 & VPR-6 Detectors
39 HPS-SAH-WP -Weather Proof Single Action Manual Pull 95 FireNET Vapor VPR-15 Detector
40 HPS-DAK-WP - Weather Proof Dual Action Manual Pull 96 FireNET Vapor VPR-SD1 & SD2 Detectors
41 HPS-DAK-SR - Manual Pull Station for Suppression Release 97 FireNET Vapor - Accessories
42 HPS-CP - Call Point Break Glass Station 98 FireNET Vapor Design Services
43 HPS-SA-EX/WP - Explosion Proof Manual Pull Station 99 OSID - Open-area Smoke Imaging Detection by Xtralis
44 SLR-24V - Photoelectric Smoke Detector 100 12-24 SIR - Carbon Monoxide Detector by Quantum Group
45 SLR-24VN - Photoelectric / Heat Smoke Detector 101 RFD-2000X - Ultraviolet & Infrared Flame Detector by Rezontech
46 SLR-24H - Photoelectric / Heat Smoke Detector 102 Solo 200 - Universal Detector Removal Tool by SD i
47 SLR-835/SLR-835H - Photoelectric Smoke Detector 103 TH Series - Linear Heat Cables by Proline
48 SLR-835B - Direct-Wire Photoelectric Smoke Detector
49 SLR-835BH - Direct-Wire Photoelectric Heat Smoke Detector L. Other
50 SLV-24M - Photoelectric Smoke Detector Marine Approved
51 DCD-135/190 - Fixed Temperature / Rate of Rise Heat Detector 104 Technical Bulletin -- Maintenance - Analog
52 DFE-135/190 - Fixed Temperature Heat Detector 105 Technical Bulletin -- Maintenance - Conventional
53 DSC-EA Rate of Rise Thermal Detector 106 ISO Certificate
54 SPC-24 - Projected Beam Smoke Detector 107 UL Conventional Product Compatibility Listings
55 HF-24 - Ultraviolet Flame Detector 108 CSFM Listings
56 DH-98 - Conventional Duct Detector
57 DH-98 - Duct Detector Remote Accessories
58 Conventional Detector Bases
E. Testing Equipment
Hochiki America Corporation FireNET Plus ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL Specifications subject to change without notice.
FireNET™Series - ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL
STANDARD FEATURES
• UL 864 9th edition Listed
• Seismic Certified
• Analog design using Hochiki’s advanced DCP
protocol for fast and robust communication
• Up to 127 sensors & modules, plus 127 analog sounder
bases, for a total of 254 points possible per loop
• Uses standard wire, no shielded or twisted pair required on
SLC loops
• Supports Class B (style 4) and Class A (style 6 or 7) SLC
loops
• 4 on board Class B (style Y) NAC circuits rated at 2.5 Amps
each
• Programmable sensitivity levels per device & automatic day/
RED CHARCOAL night sensitivity modes
• Automatic daily calibration & drift compensation routine
DESCRIPTION • Large 8-line x 40-character LCD display (320 char.)
The FireNET™ 4127 control panel is an analog addres- • 2 loop (FN-2127 Series) or 4 loop (FN-4127 Series) ver-
sions (800 addresses/sub-addr. max.)
sable fire alarm panel containing 2 or 4 SLC loops with
each loop supporting 127 devices of any combination • Dual RS-485 bus for panel network
(sensors or modules), and 127 analog sounder bases, • 2 built-in RS-232 interfaces for programming via a PC and
for a possible total of 254 points. Communication serial printer interface
between devices is transferred through standard cable • 5 on board programmable Form C relays rated at 1 amp at
(shielded or twisted pair is not required). Each panel 30VDC (Fire1, Fire2, trouble, supervisory, aux.)
includes a 5.25 amp power supply and has 4 on board • 500mA of auxiliary power available rated at 24 VDC
NAC circuits. An RS-485 bus provides communication to • Loop Explorer Windows® configuration utility
the panel network, while the RS-232 interface allows the
• 500 network wide software zones
convenience of programming via a PC. The system will
support a variety of Hochiki devices: photo, ion and heat • Network Capability of up to 64 panels
sensors, which contain a unique, patented sensor • RS485 slave bus for expansion - up to 32 FN-4127-IO
design incorporating automatic drift compensation and boards or up to 15 FN-LCD-S serial annunciators and up to
day/night sensitivity mode. Additional devices include 17 FN-4127-IO boards
contact monitors, relay controllers, supervised auxiliary • Auto-learn feature
output and short circuit isolator modules. In addition, • Fire Drill test function
interfaces to conventional detection systems can be • Walk Test function
established by using a conventional zone-monitoring
• Alarm Verification feature
module. The Loop Explorer Windows® Software
interface provides the installer with fingertip access to • FireNET is UL listed for Central Station Service, Remote
installation programming and diagnostic tools. An Station Service and Proprietary Service
Auto-learn feature offers the convenience for quick start • Operates on 120VAC or 240VAC input voltage
applications. Add to this a reputation for high quality and • Powerful & versatile Cause & Effect programming (up to 500
dedicated service makes this an exceptional product maximum, network wide) including:
both in performance and value. *Cause & Effect action
Continued on back.
*Disable function configuration
PRODUCT LISTINGS *Test mode configuration
UL 864, Local Signaling Unit.
Types: Automatic, manual,
waterflow, sprinkler supervisory,
California
S8255 Remote Station and Central 3033817
Station Service (DACT) State Fire
Non-coded signaling. Marshal
NFPA 70, 72 &13 Compliant 7165-0410:159
Specifications subject to change without notice.
Hochiki America Corporation FireNET ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL Specifications subject to change without notice.
FN-LCD-N - LCD NETWORK ANNUNCIATOR
STANDARD FEATURES
• UL 864 9th edition Listed
• 320 character liquid crystal display (8 line x 40
character)
• LED indicators for Fire, Supervisory Alarm, Pre-
Alarm, Fire Output Active, Power On, On Test, Panel
Sounder Silenced, Delay Active, More Events, Point
Bypassed, General Trouble, Power Trouble, System
Trouble & NAC Trouble
DESCRIPTION • Dual RS485 ports for primary fire network
• RS485 slave bus for expansion - up to 32 FN-4127-IO
The FN-LCD-N type LCD network annunciator is boards or up to 15 FN-LCD-S serial annunciators and
designed to be used with the FireNET analog up to17 FN-4127-IO boards
addressable system. It allows for remote access, • 2 built-in RS-232 interfaces for programming via a PC
monitoring & control of the FireNET system throughout and serial printer interface
the building. • 4 on board programmable Form C relays rated at 1
Amp at 30VDC (Fire, Supervisory, Trouble &
The FN-LCD-N is a true network annunciator that can
Auxiliary)
access, monitor & control any or all FireNET panels in
the network. Each FN-LCD-N is completely
• Same controls as the FireNET fire panel (Reset,
Panel Sounder Silence, Lamp Test, Alarm Silence,
independent. The highly intuitive user interface and Re-sound Alarm, Fire Drill, Programmable Function,
320 character LCD display of the FN-LCD-N is exactly More Events, More Fire Events, Enter & Exit)
the same as the FireNET panel. In addition to routing
• Local piezo sounder for event notification
any panel in the network to the FN-LCD-N, every event
category within each panel can also be individually
• Supports user codes & firefighter key to enable
access & controls
routed, as well as routing of all remote control functions
(reset, alarm silence, re-sound alarm) from individual
• Powered by FireNET Aux 24VDC or UL fire listed
Aux. 24VDC supply
panels. The FN-LCD-N supports the same RS485
expansion port as the FireNET panel, allowing for
• Available in red or charcoal, and can be surface or
flush mounted (using trim ring)
FireNET expansion boards and accessories to be
connected to the network annunciator.
• True network annunciator, any or all panels can be
routed to the FN-LCD-N. In addition, each event
The FN-LCD-N also has (4) output relays for fire, category can be individually routed to the FN-LCD-N
supervisory, trouble & auxiliary. The relays are
• Up to (64) FireNET panels & FN-LCD-N's can be
programmable (except supervisory).
networked together in any combination
Security is established by the use of a password or
• 500mA of auxiliary power available rated at 24VDC
firefighters enable key. Designed to be aesthetically
pleasing, the FN-LCD-N is available in charcoal grey
• Auto-learn feature
or red and can be surface or flush mounted using a • Built-in help & alarm information screens
standard trim ring kit. • Fire drill function
• Each FN-LCD-N is completely independent
PRODUCT LISTINGS • The FN-LCD-N can be configured to remote reset,
silence, resound, any or all panels on the network in
California any combination
UL 864, NFPA 70 & 72:
State Fire
Signaling Device
Marshal
S5694 7120-0410:165
ENGINEERING SPECIFICATION
The contractor shall furnish and install where indicated on the plans, the network annunciator model FN-LCD-N.
The FN-LCD-N shall connect to the FireNET fire alarm control panel (FACP) network. The network annunciator
shall be capable of annunciating on its 320 character display and local buzzer, the condition of any FireNET FACP
or network annunciator on the network. Up to 64 FN-LCD-N network annunciators or FireNET FACP's may be
connected together on the network. The FN-LCD-N shall be UL listed, and have surface or flush mount capability.
WIRING DIAGRAM
The contractor shall furnish and install where indicated on the plans, the serial remote annunciator model
FN-LCD-S. The FN-LCD-S shall connect to the FireNET fire alarm control panel (FACP) or network
annunciator (FN-LCD-N) RS485 slave bus. The serial remote annunciator shall annunciate on its 320
character display and local buzzer, the condition of its master FireNET FACP. Up to 15 FN-LCD-S serial
annunciators may be connected together on a single RS-485 FireNET slave bus. The FN-LCD-S shall be
UL listed and compatible with the Hochiki FireNET control panel, and have surface or flush mount
capability.
WIRING DIAGRAM
1522RO @
FIT JUMPER
ADDRESS COMM1 0V +24V COMM2 FOR END OF LINE
RESET W / DOG RESET COMM1 COMM2
+
+
l
ON K S
1 2 3 4 COMMS
ACTIVE
Reset
Not Used
Switch
Not Used
7. PR2
8. PR3
l +
COMMS
ADDITIONAL
I/O BOARDS
To next
( +)
AUX serial
24 VDC
l +
24X (- ) FN-LCD-
S or
other
NETWORK (+)
RS485
l +
IN RS-485
(- ) Buss
Device
NETWORK
l +
OUT
Hochiki America Corporation FireNET Graphix Software Package Specifications subject to change without notice.
FNP-LED - GRAPHIX LED DISPLAY
STANDARD FEATURES
• Available in Red and Charcoal Gray
• Available in 3 different size enclosures
• LED's comes in 3 different colors: Red, Green, or Yellow
• FNP-LED can be easily upgraded onsite with minimal
cost and effort
SPECIFICATIONS
Operating Voltage 21- 30VDC
Maximum Current 360mA
Wire Size 12AWG to 22AWG
Communication Method RS485
Max. Wiring Distance 3900ft. (1200m)
Avalible Dimensions AM2: 14.50"W x 12.25"H x 3.50"D
AM3: 14.50"W x 18.90"H x 4.25"D
AM4: 14.50"W x 24.25"H x 4.25"D
DESCRIPTION
Color Red or Charcoal
The FNP-LED system uses flexible, optic light guides Material ABS/Steel Enclosure
to illuminate areas on a floor plan, laid over a high Max. LED's AM2: 40 LEDs
resolution grid. This unique system dispenses
completely with wiring and enables indicators to be AM3: 72 LEDs
moved, removed or added onsite without the need for AM4: 88 LEDs
any wiring. All indicators can be configured to operate Operation Temperature 20°F (-6°C) to 120°F (49°C)
upon any event type and at point, zone or group level
via the powerful and intuitive Loop Explorer Cabinet Lock Type CAT 30 Key
configuartion tool. FNP-LED can be supplied with or
without optional LED's and controls. Optional LED's
indicate Power On, Fire, Trouble and Disablements
and optional controls are for Alarm Silence, Buzzer
Silence, Lamp Test, and Reset. Housed in an
attractive, slimline enclosure to match FireNET Plus PRODUCT LISTINGS
Fire Alarm Panels. High quality, full color floor plans
provide a clear and geographical indication of event
activation, which enables fast identification of the Fire
Alarm source.
S5694 California 3038713
State Fire
Marshal
7120-0410:181
Hochiki America Corporation FNP-LED Graphix Display Specifications subject to change without notice.
FN-DAC - DIGITAL ALARM COMMUNICATOR
STANDARD FEATURES
Continued on back.
Specifications subject to change without notice.
WIRING DIAGRAM
Telephone line
connections
24 VDC
Input Power
To J5 connector
on FireNET panel
MODEL DESCRIPTION
DCP-AMS Single Action Hex Key Lock
DCP-AMS DCP-AMS-KL DCP-AMS-LP Dual Action Hex Key Lock
DCP-AMS-KL Single Action Key Lock
DCP-AMS-KL-LP Dual Action Key Lock
DESCRIPTION
The DCP-AMS are the Hochiki America series of
addressable manual pull stations that provide a fast and
practical means of manually initiating a fire alarm signal.
Both single action and dual action manual pull stations
are available. Resetting of the pull station requires either
a Cat 30 key or a 1/8" hex key (depending upon the
model used).
Manual pull stations shall be Underwriters Laboratories Inc. Listed, CSFM Approved, and be installed within the limits
defined in the Americans With Disabilities Act.
WIRING DIAGRAMS
Hochiki America Corporation
OUT TO
NEXT DCP-AMS
MODULE Addressable Manual Pull Station
Ser. No.
SC- S+
S+ SC-
For Proper Installation, see HA-06-135 Rev 12/05
S6512
UL
Listed + S
Hochiki
DCP - SC
Compatible
Panel
Class B (Style 4)
Hochiki America Corporation Hochiki America Corporation Hochiki America Corporation
DCP-AMS DCP-AMS DCP-AMS
Addressable Manual Pull Station Addressable Manual Pull Station Addressable Manual Pull Station
Ser. No. Ser. No. Ser. No.
Listed
Hochiki
- SC
DCP
+ S
Compatible
Panel - SC
Class A Return (Style 6)
Class A (Style 7)
Hochiki America Corporation Hochiki America Corporation
DCP-AMS DCP-AMS
Addressable Manual Pull Station Addressable Manual Pull Station
Ser. No. Ser. No.
+ S
For Proper Installation, see HA-06-063 Rev 2/02
SIGNALING DEVICE
SIGNALING DEVICE
SIGNALING DEVICE
-
ISSUE NO. AH-9774
SC
DCP-SCI
DCP-SCI
DCP-SCI
DCP-SCI
LISTED
LISTED
LISTED
S+ SC- S+ SC-
UL (OUT) S
For Proper Installation, see HA-06-135 Rev 12/05
S6512 (OUT) S (OUT) S
For Proper Installation, see HA-06-135 Rev 12/05
S6512 (OUT) S
S5694
S5694
Hochiki
DCP
Compatible
Panel - SC
+ S
Hochiki America Corporation DCP-AMS, DCP-AMS-LP, DCP-AMS-KL AND DCP-AMS-KL-LP Specifications subject to change without notice.
FNP-1127-SLC SINGLE SLC LOOP EXPANDER
SPECIFICATIONS
Operating Voltage 24 - 40VDC
Board Current 75mA (+ loop current)
Loop Current 400mA max.
System Capacity 1 FNP-1127-SLC per FireNET Plus
panel (FNP-1127E series only)
Devices per loop 127 sensors/modules +
127 analog sounder bases, 254 total
Loop Load 50 ohms, 1uF, 1mH max.
impedance
Size 5.34" L x 4.52" W
STANDARD FEATURES
PRODUCT LISTINGS
UL 864 Category
UOJZ CNN: California
Signal System Control State Fire
Unit Sub-Assembly Marshal
S6468 NFPA72 compliant 3038713
7165-0410:180
SPECIFICATIONS
Operating Voltage 24 - 40VDC
Board Current 100mA (+ loop current)
Loop Current 400mA max. each
System Capacity One expander per FireNET
control panel
Loops per 2 SLC (Class A or B)
expander
Devices per loop 127 sensors/modules +
127 analog sounder bases, 254 total
STANDARD FEATURES Loop Load 50 ohms, 1uF, 1mH max.
impedance
• Adds two SLC loops to a two loop FireNET Size 6.3" L x 4.5" W
control panel
• Each SLC loop is capable of 127 sensors/
modules, plus 127 analog sounder bases, DESCRIPTION
for a potential total of 254 addresses per
loop (127+127 per loop)
The model FN-4127-SLC Dual SLC Loop Expander is
• FN-4127-SLC can be added at the factory or
a two loop expander board that increases the
installed in the field
standard FireNET loop capacity from 2 to 4 loops.
• Supports Class A and B wiring methods per The FN-4127-SLC can be added at the factory or
NFPA72 Styles 4, 6, and 7 (with isolators) installed in the field, and mounts within the main
• Fully supervised & power limited SLC loops control board location as a piggy-back board. By
• Supports Hochiki’s DCP (Digital adding the FN-4127-SLC, the FireNET capacity is
Communication Protocol) loop protocol increased from 254+254 to 508+508 analog
• Same functionality as built-in SLC loops of addressable points within the overall 800 address/
FireNET control panel sub-address limit. The FN-4127-SLC has the same
• One SLC expander (maximum) may be functionality as the built-in SLC loops. The FN-4127-
added per FireNET control panel SLC utilizes Hochiki’s robust DCP loop protocol for
• Each SLC loop is completely independent highly reliable and fast alarm reporting without the
and autonomous need for shielded or twisted pair wiring for the SLC
loops.
• Uses standard wire, no shielded or twisted
pair required on SLC loops
PRODUCT LISTINGS
SPECIFICATIONS
Supply Voltage 24 VDC Nominal
Quiescent Current Consumption 20mA
Cable Length 4,000ft Max.
Cable Type Belden 9271, Belden 9860
Protocol RS-485
Address Setting Dipswitch
Operating Temperature 32F~120F
Operating Humidity 90%RH
SPECIFICATIONS
Operating Voltage 12 ~ 30 VDC
Average Current Consumption 0mA (Standby)
Alarm Current 1A for 0.5 seconds
Ambient Temperature 32°F (0 C) ~ 120°F (49C)
Maximum Humidity 90% RH, non-condensing
Dimensions 4.2"W X 4.7"H X 1.1"D
Weight Approximately 3.0 ounces
Mounting 4" square electrical box
DESCRIPTION
PRODUCT LISTINGS
UL 864, NFPA 70 & 72: California
Signaling Device State Fire
S8255 Vol. 2 Marshal
7170-0410:170
WIRING DIAGRAM
24 AWG
26 AWG
-
NAC Input Compatible UL Listed
E.O.L. DEVICE Fire Alarm Control Panel
EOL
NAC Circuit Connections shown in Alarm condition NAC Circuit
For Proper Installation
S8255 see HA-06-137 Rev 07/12
SPECIFICATIONS
Models FN-ACC-R / FN-ACC-C
Max. Battery Capacity 2 x 33Ah
Max. I/O Board Capacity 6 x FN-4127-IO
Dimension 17.80"W x 14.85"H x 5.77"D
Colors Red or Charcoal
Material ABS/steel enclosure
DESCRIPTION
The FN-ACC is designed to provide a method to properly
store backup batteries for the FireNET and FireNET Plus
panels. The enclosure can also be used to mount 16
Channel I/O Boards. The battery enclosure comes in
two colors Red (FN-ACC-R) & Charcoal (FN-ACC-C) and
comes with a keylock.
DIMENSION
APPLICATION SPECIFICATIONS
X187/S187:
X187 and S187 are used to program the FireNET family
of panels. Cable Type: FireNET Family Programming
Cable Length: 8.3 feet (2.5 meters)
FN-P187 Printer Interface cable is used to connect a
Left Connector: 10 Pin Serial (Female)
serial printer to the FireNET family of panels.
Right Connector: 9 Pin - DB9 (Female)
FN-V187 VoiceNET Serial Interface Cable is used to X187: Non-Jacketed Version
interconnect a FireNET Panel with a VoiceNET Master
Panel. S187: Jacketed Version
Continued on back
WIRING DIAGRAMS:
PROGRAMMING INTERFACE:
PRINTER INTERFACE:
Hochiki America Corporation • Serial Cables Specifications subject to change without notice.
ENGINEERING SPECIFICATIONS, continued
The base shall permit direct interchange with the HOCHIKI America AIE-EA ionization type smoke sensor, ALG-V
Photoelectric type smoke sensor, and the ATG-EA heat sensor.
The sensitivity of the sensor shall be capable of being measured by the control panel.
The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking
feature shall be optional and can be implemented when required.
BASES
The HOCHIKI America except for ASB both YBN-NSA-4 and the HSB-NSA-6 mounting bases are electronics free and are
a simple rugged design with screw terminals for wiring connections. A common mounting base allows sensor inter-
change and maintains loop continuity when sensors are removed. A simple anti-tamper head locking system is provided
which is enabled by removing a small plastic tab on the back of the sensor. Once locked, the head can be removed using
a small diameter screw driver.
UL LISTED
COMPATIBLE NEXT DEVICE
8mA Max.
CONTROL
PANEL
NUMBER OF ASB BASES PERMITTED
LOOP OUT
# of Bases Maximum Auxiliary 24VDC Power
In Alarm Wire Resistance (Total Auxiliary
NEXT DEVICE Run Length)
(Aux.) (+) FIGURE A
TOP VIEW
8mA MAX. 127 1.4 ohms
OUTPUT
NOTE: Class A style 7 wire configuration requires the installation of short circuit isolators (SCI). 75 2.4 ohms
LOOP IN
DO NOT CONNECT FOR CLASS B (STYLE 4)
60 3.0 ohms
CONNECT FOR CLASS A (STYLE 6 OR 7)
50 3.6 ohms
30 6.1 ohms
HO HA
HO HA
C HIK-08
C HIK-08
I AM 7 B
I AM 7 B
M M
-06 AS
-06 AS
ER V.
ER V.
ICA B
ICA B
RE
RE
CO
CO
RP
RP
.
.
SC
SC
20 9.1 ohms
G
G
TP
TP
3
3
F
F
DE
DE
TP
TP
TS
TS
1
1
C
AUX POWER
TP
TP
S
S
2
15 12.2 ohms
S5
S5
6
6
S
BLK
BLK
BLK
BLK
RED
RED
C-0 03
C-0 03
RED
RED
21
21
2
FIGURE B
OPERATION
The detection chamber consists of a light emitting diode
(LED) and photodiode arrangement. The chamber is
designed such that light emitted by the LED cannot
Shown without base
normally reach the photo diode. In the event of fire,
STANDARD FEATURES particles of smoke enter the chamber and scatter the
• Low Profile - Only 2.0" high, including base light. As the smoke level increases, the scattering effect
increases, causing more light to hit the photodiode. The
• Simple and reliable device addressing method chamber contains a unique baffle design which allows
• Automatic compensation for sensor contamination smoke to enter the chamber while preventing external
• Built-in fire test feature light from affecting the photodiode. The photodiode input
• Uses the noise immune Digital Communication level is sampled to sense smoke density.
Protocol (DCP), which utilizes interrupts for fast
response to fires When the smoke density exceeds a preset threshold
• Two built-in power/alarm LED's the sensor transmits an interrupt to the fire control panel
• Programmble Non-polling LED's indicating a fire condition. The fire alarm control panel
can adjust the sensor threshold to compensate for
• Non-directional smoke chamber
contamination.
• Vandal resistant security locking feature
• Removable smoke labyrinth for cleaning or Up to 127 devices are permitted on each loop. A sensor
replacement address can be set by a hand held programming unit.
• Compatible with the AIE-EA ionization detector, ALG-V The sensor mounts to an electronics free base and
Photoelectric detector & the ATG-EA heat detector incorporates a locking mechanism for secure installation.
• Smoke chamber design reduces the susceptibility to The base provides mounting slots, terminals for field wiring
nuisance alarms caused by steam. and a third contact for a remote indicator/LED. The sensor
incorporates dual LED's for easy viewing of sensor status.
SPECIFICATIONS
Operating Voltage 17-41 VDC
Standby Current 390μA ENGINEERING SPECIFICATIONS
Alarm Current 800μA The contractor shall furnish and install where indi-
Transmission Method DCP - Digital cated on the plans, photoelectric sensors HOCHIKI
Communication Protocol America Model ALK-V. The combination sensor
Maximum Humidity 95% RH Non-Condensing head and twist lock base shall be UL listed compat-
UL Ambient Installation 32°F to 100° F ible with a UL listed fire alarm control panel.
Temperature Range (0° C to 37.8° C)
Operating Temperature 14°F to 122° F
Range (-10° C to 50° C) PRODUCT LISTINGS
Sensitivity Range 0.5 - 3.8%/FT@300FPM
0.5 - 2.74%/FT@2000FPM California
0.5 - 2.68%/FT@4000FPM
State Fire
Air Velocity Range 0-4000 fpm
3034568 Marshal
Color & Case Material Bone PC, Black / ABS Blend
7272-0410:173
Weight 3.4oz (5.1 oz. with 4" base) S1383
Bases 4" YBN-NSA-4
6" HSB-NSA-6 & ASB Continued on back.
The sensitivity of the sensor shall be capable of being measured by the control panel.
The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking
feature shall be optional and can be implemented when required.
BASES
The HOCHIKI America except for ASB both YBN-NSA-4 and the HSB-NSA-6 mounting bases are electronics free and are
a simple rugged design with screw terminals for wiring connections. A common mounting base allows sensor inter-
change and maintains loop continuity when sensors are removed. A simple anti-tamper head locking system is provided
which is enabled by removing a small plastic tab on the back of the sensor. Once locked, the head can be removed using
a small diameter screw driver.
UL LISTED
COMPATIBLE NEXT DEVICE
8mA Max.
CONTROL
PANEL
NUMBER OF ASB BASES PERMITTED
LOOP OUT
# of Bases Maximum Auxiliary 24VDC Power
In Alarm Wire Resistance (Total Auxiliary
NEXT DEVICE Run Length)
(Aux.) (+) FIGURE A
TOP VIEW
8mA MAX. 127 1.4 ohms
OUTPUT
NOTE: Class A style 7 wire configuration requires the installation of short circuit isolators (SCI). 75 2.4 ohms
LOOP IN
DO NOT CONNECT FOR CLASS B (STYLE 4)
60 3.0 ohms
CONNECT FOR CLASS A (STYLE 6 OR 7)
50 3.6 ohms
30 6.1 ohms
HO HA
HO HA
C HIK-08
C HIK-08
I AM 7 B
I AM 7 B
M M
-06 AS
-06 AS
ER V.
ER V.
ICA B
ICA B
RE
RE
CO
CO
RP
RP
.
.
SC
SC
20 9.1 ohms
G
G
TP
TP
3
3
F
F
DE
DE
TP
TP
TS
TS
1
1
C
AUX POWER
TP
TP
S
S
2
15 12.2 ohms
S5
S5
6
6
S
BLK
BLK
BLK
BLK
RED
RED
C-0 03
C-0 03
RED
RED
21
21
2
FIGURE B
OPERATION
The detection chamber consists of a light-emitting diode
(LED) and photodiode arrangement. The chamber is
designed such that light emitted by the LED cannot
Shown without base normally reach the photo diode. In the event of fire,
particles of smoke enter the chamber and scatter the
STANDARD FEATURES light. As the smoke level increases, the scattering effect
increases, causing more light to hit the photodiode. The
• Low profile - Only 2.00" high, including base chamber contains a unique baffle design which allows
• Simple and reliable device addressing smoke to enter the chamber while preventing external
• Automatic compensation for sensor contamination light from affecting the photodiode. The photodiode input
• Built-in fire test feature level is sampled to sense smoke density.
• Uses the noise-immune Digital Communication
Protocol (DCP), which utilizes interrupts for fast When the smoke density exceeds a preset threshold
the sensor transmits an interrupt to the fire control panel
response to fires indicating a fire condition. The fire alarm control panel
• Two built-in power/alarm LEDs can adjust the sensor threshold to compensate for
• Programmble non-polling LEDs contamination.
• Non-directional smoke chamber
• Vandal resistant security locking feature Up to 127 devices are permitted on each SLC loop. A
• Removable smoke labyrinth for cleaning or sensor address is set by a hand-held programming unit.
replacement The sensor mounts to an electronics-free base and
incorporates a locking mechanism for secure installation.
The base provides mounting slots, terminals for field wiring
SPECIFICATIONS and a third contact for a remote indicator/LED. The sensor
Operating Voltage 17-41 VDC incorporates dual LEDs for easy viewing of sensor status.
Standby Current 450μA
Alarm Current 540μA ENGINEERING SPECIFICATIONS
Transmission Method DCP - Digital
Communication Protocol The contractor shall furnish and install where indi-
Maximum Humidity 95% RH Non-Condensing cated on the plans, photoelectric sensors Hochiki
America Model ALN-V. The combination sensor
UL Temperature Range 32°F to 115° F head and twist lock base shall be UL listed compat-
(0° C to 47° C) ible with a UL listed fire alarm control panel.
Operating Temperature 14°F to 122° F
Range (-10° C to 50° C)
PRODUCT LISTINGS
Sensitivity Range 0.7 - 4.0%/FT@300FPM
0.7 - 3.86%/FT@2000FPM
0.7 - 2.65%/FT@4000FPM California
Air Velocity Range 0-4000 fpm State Fire
Color & Case Material Bone / White - ABS Blend Pending Marshal
Weight 3.4oz (5.1 oz. with 4" base)
Bases YBN-NSA-4, HSB-NSA-6, S1383 7272-0410:0204
ASB, SCI-B4 and SCI-B6 Continued on back.
The sensitivity of the sensor shall be capable of being measured by the control panel.
The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking
feature shall be optional and can be implemented when required.
BASES
The Hochiki America HSB-NSA-6 and the YBN-NSA-4 mounting bases are electronics free and are a simple rugged
design with screw terminals for wiring connections. A common mounting base allows sensor interchange and maintains
loop continuity when sensors are removed. A simple anti-tamper head locking system is provided which is enabled by
removing a small plastic tab on the back of the sensor. Once locked, the head can be removed using a small diameter
screwdriver.
NOTE: Fire alarm control panel compatibility is required for DCP products.
DCP communications protocol allows system components (DCP sensors AIE-EA, ALG-V, ACA-V, ACC-V, ALK-V,
ATJ-EA and ATG-EA, bases and modules) to be used concurrently on a system's SLC (Signaling Line Circuit).
OPERATION
The ATJ-EA incorporates a highly linear thermistor circuit.
The specially designed cover protects the thermistor
while allowing maximum air flow. The thermistor circuit
produces a voltage proportional to the temperature; this
information is transmitted to the control panel as a digital
STANDARD FEATURES value. When the ambient temperature exceeds a pre-
programmed threshold (fixed temp or rate of rise), the
• Low profile - Only 2.00" high, including base sensor transmits an interrupt to the control panel
• Simple and reliable device addressing method indicating a fire alarm. The fire alarm control panel can
• Uses the noise immune Digital Communication adjust the sensor's fixed temperature threshold for
Protocol (DCP), which utilizes interrupts for fast different installation requirements.
response to fires
• Rate of Rise temperature threshold = 15°F/Min Up to 127 devices may be installed on each SLC loop.
(determined by panel) The sensor address may be set by a hand-held
• Adjustable threshold temperature = 135°F - 190°F programming unit. The sensor mounts to an electronics-
(determined by panel) free base and incorporates a locking mechanism for
• UL maximum spacing of 70 feet security. The base provides mounting slots, terminals
for field wiring and a third terminal for a remote indicator/
SPECIFICATIONS LED. The sensor has dual LEDs for easy viewing of the
sensor status.
Operating Voltage 17 - 41 VDC
Standby Current 350μA ENGINEERING SPECIFICATIONS
Alarm Current 500μA
Transmission Method DCP - Digital Heat sensors are installed in accordance with NFPA
Communication Protocol (National Fire Protection Association) 72, the UL Listed
Rate of Rise 15°F/Min. (8.3° C/Min.) Spacing Requirements and the rules and regulations set
forth by the local authorities having jurisdiction. The con-
UL Temperature Range 135°F to 190°F
tractor shall furnish and install, where indicated on the
(57.2°C to 87.8°C)
plans, Fixed Temp / Rate of Rise Automatic heat sen-
Operating Temperature 32°F to 190° F
sors.
Range (0° C to 87.8° C)
UL Maximum Spacing 70 ft. PRODUCT LISTINGS
Maximum Humidity 95% RH Non-Condensing
Color & Case Material Bone / White - ABS blend California
Weight 3.2 oz State Fire
(4.9 oz. with 4" base) Marshal
Bases YBN-NSA-4, HSB-NSA-6, Pending
BASES
The HOCHIKI America HSB-NSA-6 and the YBN-NSA-4 mounting bases are electronic free and are a simple, rugged
design with screw terminals for wiring connections. A common mounting base allows sensor interchange and main-
tains loop continuity when sensors are removed. A simple anti-tamper head locking system is provided which is
enabled by removing a small plastic tab on the back of the sensor. Once locked, the head can be removed using a
small diameter screwdriver.
NOTE: Fire alarm control panel compatibility is required for DCP products.
DCP communications protocol allows system components (DCP sensors AIE-EA, ALG-V, ACA-V,
ACC-V, ALK-V, ALN-V, ATJ-EA and ATG-EA, bases and modules) to be used concurrently on a system's
Hochiki America Corporation ATJ-EA
SLC (Signaling Line Circuit). Specifications subject to change without notice.
ACA-V ANALOG MULTI-CRITERIA SENSOR
APPLICATION
The HOCHIKI America ACA-V Multi-Criteria Smoke Sensor is
particularly suited for detecting smoke produced by a wide
range of combustibles found in various applications.
Temperature monitoring is achieved by a thermistor placed
for optimum sensitivity. Hochiki's unique design allows fast
response to flaming fires as well as smoldering fires while
minimizing false alarms.
OPERATION
The ACA-V chamber consists of a light emitting diode (LED)
and photodiode arrangement. The chamber is designed
such that light emitted by the LED cannot normally reach the
Shown without base
photodiode. In the event of fire, particles of smoke enter the
chamber and scatter the light. As the smoke level increases,
STANDARD FEATURES the scattering effect increases, causing more light to hit the
photodiode. The chamber contains a unique design which
• Low Profile - Only 2.23" high, including base allows smoke to enter the chamber while preventing external
• Simple and reliable device addressing method light from affecting the photodiode. The photodiode input
• Automatic compensation for sensor contamination level is sampled to sense smoke density. When the smoke
• Built-in fire test feature density exceeds a preset threshold the sensor transmits an
• Uses the noise immune Digital Communication Protocol interrupt to the fire control panel indicating a fire condition.
(DCP), which utilizes interrupts for fast response to fires The fire alarm control panel can adjust the sensor threshold
to compensate for contamination.
• Two built-in power/alarm LED's
• Programmable Non-polling LED's The ACA-V Heat portion incorporates a highly linear
• Non-directional smoke chamber thermistor circuit, with the thermistor mounted externally.
• Vandal resistant security locking feature The specially designed cover protects the thermistor while
• Removable smoke labyrinth for cleaning or replacement allowing maximum air flow. The thermistor circuit produces
• Compatible with the analog sensors a voltage proportional to temperature which is scaled, and
transmitted as a digitally encoded value to the control panel.
When the ambient temperature exceeds a pre-
programmed threshold (fixed temperature), the sensor
SPECIFICATIONS transmits an interrupt to the control panel indicating a fire
Operating Voltage 17-41 VDC alarm. The fire alarm control panel can adjust the sensor
Standby Current 450μA threshold for different Standard's requirements.
Alarm Current 540μA
Transmission Method DCP - Digital Up to 127 devices are permitted on each loop. A sensor
Communication Protocol
address can be set by a hand held programming unit. The
Operating Temperature 14°F (-10°C) - 122°F (50°C)
UL Temperature Range 135°F (57°C) - 150°F (65°C) sensor mounts to an electronics free base and incorporates
Storage Temperature -4°F (-20°C) - 140°F (60°C) a locking mechanism for secure installation. The base
Range provides mounting slots, terminals for field wiring and a third
Maximum Humidity 95% RH Non-Condensing contact for a remote indicator/LED. The sensor incorporates
Color & Case Material Ivory dual LED's for easy viewing of sensor status.
Weight 4.2 oz (5.9 oz. with 4" base)
Dimensions 3.9"W x 1.8"H PRODUCT LISTINGS
Bases 4" YBN-NSA-4
6" HSB-NSA-6
6" ASB California
State Fire
3042214 Marshal
7272-0410:182
S1383
Continued on back.
The base shall permit direct interchange with the HOCHIKI America ALG-V Photoelectric type smoke sensor, ALK-V/
ALK-V2 Photoelectric type sensor, AIE-EA ionization type smoke sensor, and the ATG-EA heat sensor.
The sensitivity of the sensor shall be capable of being measured by the control panel.
The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking
feature shall be optional and can be implemented when required.
BASES
The HOCHIKI America YBN-NSA-4 and the HSB-NSA-6 mounting bases are electronics free and are a simple rugged
design with screw terminals for wiring connections. A common mounting base allows sensor interchange and maintains
loop continuity when sensors are removed. A simple anti-tamper head locking system is provided which is enabled by
removing a small plastic tab on the back of the sensor. Once locked, the head can be removed using a small diameter
screw driver.
NOTE: Fire alarm control panel compatibility is required for DCP products.
State-of-the-art communications protocol, DCP, allows system components (DCP sensors AIE-EA, ALG-V, ACA-V
ALK-V and ATG-EA, bases and modules), to be used concurrently in a system's SLC (Signaling Line Circuit).
Hochiki America Corporation ACA-V Multi-Criteria Sensor Specifications subject to change without notice.
ANALOG SENSOR BASES
SPECIFICATIONS
Security Feature Plastic Tamper-lock
Color & Material Bone PC / ABS Blend
Dimensions HSB-NSA-6: 6 inches
YBN-NSA-4: 4 inches
Compatible Detectors ALG-V, ALK-V, ALK-D, AIE-EA,
ATG-EA, ACA-V
APPLICATION
OPERATION
MEA
284-91-E Vol. IV
3022559
Continued on back.
Specifications subject to change without notice.
The base shall permit direct interchange with the HOCHIKI America AIE-EA Ionization type Smoke Sensor, ALG-V,
ALK-V Photoelectric Smoke Sensor, ALK-D Photoelectric Smoke Sensor for in-duct use, ATG-EA Heat Sensor, and
the ACA-V Multi-criteria Sensor.
The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking
feature shall be optional and can be implemented when required.
YBN-NSA-4
(+)
UL LISTED
COMPATIBLE
DCP LOOP
(-) 8mA MAX.
OUTPUT
UL LISTED (+)
POWER LIMITED
SUPPLY
8mA MAX.
OUTPUT
HSB-NSA-6
(+)
UL LISTED
COMPATIBLE
DCP LOOP
(-)
UL LISTED
POWER LIMITED
SUPPLY (+)
NOTE: Fire alarm control panel compatibility is required for DCP products.
State-of-the-art communications protocol, DCP, allows system components (DCP sensors AIE-EA,
ALG-V, ALK-V, ALK-D, ACA-V and ATG-EA, bases and modules), to be used concurrently in a system's signaling line circuit.
Hochiki America Corporation Analog Sensor Bases Specifications subject to change without notice.
ASB - ANALOG SOUNDER BASE
SPECIFICATIONS
Operating Voltage 17 ~ 41 VDC
SLC Current 110µA (Typical)
Consumption 110µA (Alarm)
Auxiliary Supply Voltage 16 ~ 31 VDC
Auxiliary Current 550µA (Typical)
Consumption 18mA (Alarm)
Sound Pressure Level 85dB
at 10ft.
Max. Quantity Per Loop 127
UL Ambient Installation 32°F (0°C) ~ 100°F (38°C)
Shown without sensor Shown with sensor Temperature Range
Operating Temperature 32°F (0°C) ~ 122°F (50°C)
Range
Dimensions (without 1.34”H x 5.94”D
STANDARD FEATURES sensor)
Weight 0.455 lb
Relative Humidity 93% RH Non-Condensing
• Programmable evacuation codes - Continuous,
Compatible Detectors ALG-V, ALK-V, AIE-EA, ATG-EA,
March, ANSI Temporal patterns ACA-V
• Base learns the sensor address and assumes an
upper range address (128-254)
• Up to 127 sensors and 127 ASBs can be used on
one SLC loop DESCRIPTION
• Can be alarmed or reset by zone or by individual
address
• ASB SLC loop wire resistance = 50 ohms Max. The ASB Analog Sounder Base is designed for use
(total SLC wire run length) with Hochiki analog sensors ALG-V, ALK-V, ACA-V,
• High sound pressure level (85dB SPL at 10 feet) AIE-EA, and ATG-EA. Each addressable base is to
be connected to a Hochiki America Corporation DCP
Signaling Line Circuit (SLC). The ASB provides an
audible alarm in the immediate vicinity. Typical
applications are hotels, apartments, and hospitals.
FIRE ALARM
CONTROL NEXT DEVICE
8mA Max.
PANEL
LOOP OUT
NEXT DEVICE
(Aux.) (+) FIGURE A
TOP VIEW
8mA MAX.
OUTPUT
NOTE: Class A style 7 wire configuration requires the installation of short circuit isolators (SCI).
LOOP IN
CONNECT FOR CLASS A (STYLE 6 OR 7)
HO H A-
HOC H A-
C HI 08
H IK08-0 AS
KI -067 AS B
I A 67 B
M M
AM RE
M ER R EV
ERI V.
IC A . B
CA B
C OR
CO
RP
P.
.
SC
SC
G
G
TP
TP
3
3
F
F
DE
DET
TP1
TP
TS
SC
C
1
AUX POWER
TP
TP
S
S
2
2
S5
S 56
6
S
BLK
BLK
BLK
BLK
RE D
RE
C-01 03
C-01 03
RE
RED
2
2
D
FIGURE B
BOTTOM VIEW
SPECIFICATIONS
Operating Voltage 17 - 41 VDC
Current Consumption Normal: 160uA
Active: 10mA
Security Feature Plastic Tamper-lock
Color & Material Bone PC / ABS Blend
Dimensions SCI-B6: 6 inches
SCI-B4: 4 inches
Compatible Detectors ALG-V, ALK-V, ALK-D, AIE-EA,
ATG-EA, ACA-V
APPLICATION
SCI-B6 & SCI-B4 The HOCHIKI America SCI-B4 and the SCI-B6 are short
circuit isolation mounting bases containing a simple rug-
ged design with screw terminals for wiring connections.
These common mounting bases allows sensor inter-
STANDARD FEATURES change and maintains loop continuity when sensors are
removed. A simple anti-tamper head locking system is
• UL Listed provided which is enabled by removing a small plastic
• Ability to detect short circuit conditions tab on the back of the sensor. Once locked, the head
• Designed for use with all DCP analog sensor. can only be removed using a small diameter screw-
• Available in 4 and 6 inch models driver.
• Built-in LED indication upon short circuit condition
• Contains a security locking tab for tamper OPERATION
protection
PRODUCT LISTINGS
California
State Fire
Marshal
7300-0410:186
S1383
Continued on back.
Specifications subject to change without notice.
The base shall permit direct interchange with the HOCHIKI America AIE-EA Ionization type Smoke Sensor, ALG-V,
ALK-V Photoelectric Smoke Sensor, ALK-D Photoelectric Smoke Sensor for in-duct use, ATG-EA Heat Sensor, and
the ACA-V Multi-criteria Sensor.
The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking
feature shall be optional and can be implemented when required.
SC I- B 4: T E RM INA L CO NN EC T IO N 1, 2, 5 A ND 6 W IRIN G SH O W N
IS S UP E RV ISE D A ND INH ER E NT LY PO W ER LIM IT E D
W IR IN G D IA G RA M
FA CP P lea se refe r to U L liste d F ire A larm C o ntro l
P an e l ins tallation ins tru ction s for w iring - +
de tails.
+
LO OP
O UT -
G roup of various D C P S ensors
LOO P
+ and/or M odules w ith SC I
IN -
- +
S
IK xx S C
I A x R I-
ME E B
RIC V. A
A
S 56
CO
RP
.
- +
- +
NOTE: Fire alarm control panel compatibility is required for DCP products.
State-of-the-art communications protocol, DCP, allows system components (DCP sensors AIE-EA,
ALG-V, ALK-V, ALK-D, ACA-V and ATG-EA, bases and modules), to be used concurrently in a system's signaling line circuit.
Hochiki America Corporation Short Circuit Isolator Analog Sensor Bases Specifications subject to change without notice.
DH-99 ANALOG DUCT DETECTOR
STANDARD FEATURES
• Detects and limits the spread of smoke
throughout building HVAC ducts
• Compatible with building automation and fire
alarm systems
• Installs quickly and easily
• No screens or filters to clean
• Rugged gray steel back box with clear cover
• Accessories - Remote LED alarm
indication capability (DH-99-AR only)
• Meets UL 268A Requirements
APPLICATION
The HOCHIKI AMERICA DH-99 Analog duct smoke
detector provides early detection of smoke and
Duct housing with an ALK-D analog
photoelectric sensor.
products of combustion present in air moving through
HVAC ducts in Commercial, Industrial and Residential
applications. The DH-99 is designed to prevent the
SPECIFICATIONS recirculation of smoke in areas by the air handling
D uct Detector Model # DH-99-A DH-99-AR systems, fans and blowers. Complete systems may
be shut down in the event of smoke detection. The
Detector Head model ALK-D
HOCHIKI AMERICA DH-99-A and the DH-99-AR
Detector Head Type Analog Photoelectric operate on a DCP powered loop (24 VDC source
Communication
required for DH-99-AR)
DCP Powered Loop
DCP Powered Loop/ PRODUCT DESCRIPTION
Input Voltage DCP Powered Loop
24V DC The DH-99 is designed and built to meet all local
Standby Current 390μA 390μA requirements, as well as the NFPA regulations
Alarm Current 540μA 540μA regarding duct smoke detectors. The DH-99-AR is
provided with output terminals for remote accesso-
2 form C rated at
Alarm Contacts N/A 10A@250V AC ries such as a remote status indicators and reset
key switches or push buttons. Air sampling is
Sensitivity Test Method Control Panel
accomplished by two tubes which protrude into the
Power,Alarm, duct. An exhaust tube of one standard length (7.5")
Remote Indication Compatibility
N/A Horn/Piezo
(Refer to DH-98 Accessories)
Test is supplied in the installation kit with the smoke duct
unit. Once the duct width has been determined the
Air Velocity 300 to 4000 ft/min.
air intake sampling tubes must be ordered. Sam-
Ambient Temperature 32°F to 100°F (0°C to 38°C) pling tubes are supplied in three standard lengths
Humidity 10% to 85% Relative Humidity 2.5 ft., 5 ft. and 10 ft. and cut to size to fit the duct.
(non-condensing)
Housing Material 18 G.A. steel backbox, clear plastic cover PRODUCT LISTINGS
Finish Grey Paint
Dimensions 91/8"L x 71/4"W x 21/4"H California
State Fire
Maximum Net Weight 3lbs. Marshal
Sampling Tubes 2.5ft., 5ft. or 10ft. Pending
S1383 3240-0410:0155
Specifications subject to change without notice.
Continued on back.
The compact DH-99-AR contains 2 sets of form "C" contacts rated at 10 amps.
The pilot and alarm visual indicators, provided on the front of the DH-99-AR duct unit, signal the operating
status of the device. A manual test/ reset switch is located along side the visual indicators.
ENGINEERING SPECIFICATIONS
Air duct smoke detectors shall be HOCHIKI AMERICA DH-99 Series. The detectors shall be listed by Underwriters
Laboratories per UL 268A. The detectors shall operate at air velocities from 300 feet per minute to 4000 feet per
minute.
The duct detector housings shall be of metal construction and complete mechanical installation may be
performed without removal of the detector cover. The duct detector shall not require additional filters or screens
which must be maintained. The housing shall contain a base which will accept an analog photoelectric sensor
head. Terminal connections shall be of the screw type and be a minimum of #6 screw. For installations
requiring relay functions, terminals shall be provided for remote pilot, remote alarm indication, strobe/ horn and
remote key switch. For installation not requiring relay functions, visual indication of alarm and power must be
provided on detector front. A manual reset switch shall be located on the front of the device (DH-99-AR only).
All wiring must comply with local codes and regulations.
WIRING DIAGRAMS
+ -
REMOTE
ADDRESSABLE ALARM
LOOP LED
+
1 2 3 4 5 6 7 8 9 10 11 12
- +
C C
REMOTE
NC NO NC NO
PILOT LED ALARM CONTACTS ALARM CONTACTS
10.0A @ 250VAC 10.0A @ 250VAC
S (+)
TO NEXT SENSOR
ANALOG ADDRESSABLE
OR RETURN
SC (-) FIELD LOOP WIRING
TO CONTROL PANEL
Terminate Remote Accessories as indicated above (if required).
This is not a self-contained stand alone detector.
A U.L. Listed Analog Addressable Fire System is required.
Hochiki America Corporation DH-99 ANALOG DUCT DETECTOR Specifications subject to change without notice.
DCP-SOM-A/-AI - CLASS A SUPERVISED OUTPUT MODULE
SPECIFICATIONS
Supply Voltage (S-SC) 25.3 ~ 39 VDC
Auxiliary Supply Voltage 24 VDC
Average Current Consumption
SOM-AI - 420μA (Typical), SOM-A - 220μA (Typical)
(on S-SC Line) Maximum 6mA: Red Alarm LED On
Current Consumption on
Auxiliary Power Lines Typical 50μA
SCI On Resistance
40m ohm Max. (Normal Condition)
SCI Fault Detection Threshold 12 volts (Typical)
SCI Isolation Current
(Short Circuit Condition) 10mA (Typical)
Maximum Quantity Per Loop 127
STANDARD FEATURES Dimensions 4.2"W x 4.7"H x 1.4"D
Ambient Temperature 32°F (0°C) ~ 120°F (49° C)
• Built-in SCI circuitry (SOM-AI only)
• Flexible application Mounting 4" square electrical box
• Quick response to emergency conditions Maximum Output Current 2A@24VDC power limited
• Operation parameters are maintained by the Relative Humidity 90% RH Non-condensing
module, and individual communication with the
control system during emergency conditions
is not required DESCRIPTION
• Contacts are rated 2.0 Amps @ 24VDC The Class A Supervised Output Modules (DCP-SOM-A &
• Programming is highly flexible providing 16 SOM-AI) have been designed to provide application
priority states plus zoning capability flexibility and quick response to emergency conditions.
• Programmed device output is turned off, silenced, Flexibility is provided by a wide range of operating
or programmed to output the selected pattern modes, including supporting multi-zone operations, and/
• UL 864 Listed or functions, up to 16 different modulation patterns and
multi-state programming. The operating parameters for
the DCP-SOM-A & -AI are maintained by the module
and do not require individual communication with the
control system during emergency conditions to operate.
PRODUCT LISTINGS The control panel simply broadcasts system conditions
on the Signaling Line Circuit (SLC) and the DCP-SOM-A
California & -AI modules do the rest based upon the custom
State Fire configuration. Each DCP-SOM-A & -AI provides a single
Marshal 3036830 Class B or Class A circuit rated for 2.0 Amps @ 24
7300-0410:150 VDC. Each DCP-SOM-A & -AI also requires a 24 VDC
S5694
power source in addition to the SLC.
IN+
For Proper Installation CIRCUIT OUT+, OUT-, IN+, IN- SHOWN IS
See HA-06-138 Rev 07/12
TB3 SUPERVISED AND INHERENTLY POWER
IN- LIMITED. CONNECT POWER LIMITED
CLASS-B CLASS-A
SUPPLY TO 24V+ & 24V-.
CLASS-B CLASS-A
!
U.L. LISTED SIGNALING DEVICES SELECT CLASS-A WIRING
BY SETTING THIS JUMPER
+ +
- -
CLASS-B CLASS-A
!
U.L. LISTED SIGNALING DEVICES SELECT CLASS-B WIRING
BY SETTING THIS JUMPER
+ E.O.L. DEVICE
- PART NUMBER
0400-03180
S P E C IF IC A T IO N S
S u p p ly Vo lta g e (S -SC ) 2 5 .3 ~ 3 9 VD C
A u xilia r y Su p p ly Vo lt a g e 24 VDC
A ve ra g e C u rr e n t 1 5 4 µA ( Ty p ica l)
C o n s u m p tio n M a x im u m : 6 m A (R e d A la rm
(O n S-S C L in e ) LED O n)
C u r re n t C o n s u m p tio n o n T yp ica l 1 .1 5 m A
A u xilia r y Po w e r L in e s
M a xim u m Ou tp u t C u rre n t 2 A @ 2 4 V D C P o w e r L im it e d
S o le n o id C u r re n t M a x im u m : 4 4 3 m A
C o n s u m p tio n
C o m p a t ib le So le n o id s AS C O : 8 2 1 0 G 2 0 7
Pa r ke r/Sk in n e r:
7 3 2 1 8 B N 4 U M L VN O C 1 1 1 C 2
E OL D e v ic e 1 0 K o h m s R e sist o r & 1 N 5 8 1 7
D io d e
S O M -R D im e n sio n s 4 . 2 ”W x 4 . 7 ”H x 1 .4 ”D
O p e ra tin g T e m p e ra tu re 3 2 °F (0 °C ) ~ 1 2 0 °F (4 9 °C )
M o u n tin g 4 ” sq u a r e e le ct rica l b o x
R e la tive H u m id ity 9 0 % R H N o n -C on d e n sin g
STANDARD FEATURES
DESCRIPTION
• UL 864 9th Edition Listed
The Supervised Output Module (DCP-SOM-R) is
• Flexible Pre-Action application
designed for Single-Interlock Pre-Action sprinkler
• Quick response to emergency conditions systems. During an alarm condition, the DCP-SOM-
• Operation parameters are maintained by the R output will operate which will trip a solenoid valve,
module, and individual communication with the allowing water to fill the sprinkler system piping.
control system during emergency conditions Water is not discharged until a sprinkler head
is not required operates due to heat from the fire. Pre-Action
• Contacts are rated 2.0 Amps @ 24VDC systems provide an added level of protection against
• Programming is highly flexible providing 16 inadvertent water discharge and are frequently
priority states plus zoning capability employed in water sensitive locations such as archival
Program status: vaults, fine art storage rooms, rare book libraries and
• LED will flash red or green computer centers.
The DCP-SOM-R requires 24VDC power from a UL
• Programmed device output is turned off, silenced, 1481 Listed, Regulated Power-Limited supply. The
or programmed to active continuously
24VDC power is supervised by the DCP-SOM-R. An
End-of-Line Device (EOLD) is included for supervision
of the output wiring and solenoid coil. The DCP-SOM-
R must be addressed from 1 – 127 prior to installation
PRODUCT LISTINGS on the SLC loop.
The DCP-SOM-R comes equipped with an SOM-R-DS
California Disable Key Switch. This switch is used, along with
State Fire a FRCME module, to disable the output of the DCP-
Marshal 3042214 SOM-R for system testing or maintenance. To ensure
S5694 7300-0410:150
proper operation of the DCP-SOM-R, follow all
installation, wiring, and programming instructions.
Specifications subject to change without notice.
Continued on back.
The contractor shall furnish and install where indicated on the plans, addressable Supervised Output Module (DCP-
SOM-R). The modules shall be UL listed and compatible with FireNET 2127/4127 and FireNET Plus Fire Alarm
Control Panel. The device address shall be electrically programmable and stored in EEPROM. A bi-colored LED
shall indicate device status.The DCP-SOM-R shall be supplied with a plastic cover and shall be suitable for mounting
to a 4" square or double gang electrical back box. The DCP-SOM-R shall provide a monitor LED that is visible from
outside the cover plate. DCP-SOM-R is provided with a disable switch (SOM-R-DS), which shall be suitable for
mounting to a single gang electrical back box.
WIRING DIAGRAM
SOLENOID
SC
GND
INHERENTLY POWER LIMITED
S
OUT+
For Dry Indoor Use Only
1
U.L. LISTED
SOLENOID
VALVE
IN IN OUT OUT
SOM-R
YELLOW
YELLOW
10KOhms EOL
U.L. LISTED
FireNET 4127 SOM-R-DS
or FireNET Plus Disable Key Switch
FIRE CONTROL
PANEL
IN-A
S+
SC-
IN-B
AH-9755
FRCME
FIGURE 4
WIRING DIAGRAM
SPECIFICATIONS
Supply Voltage (S-SC) 25.3 ~ 39 VDC
Average Current 550µA (Typical)
Consumption 660µA (Alarm)
Programmable Input Monitoring Inputs
EOL Device 10K ohms Resistor
Max. Quantity Per Loop 127
Dimensions 3.0”W x 1.9”H x 0.5”D
Operating Temperature 32°F (0°C) ~ 120°F (49°C)
Mounting Single gang electrical box
Relative Humidity 90% RH Non-Condensing
DESCRIPTION
The Hochiki DCP-FRCME-P Fast Response Contact
Monitoring Modules are designed to be used with pull
STANDARD FEATURES stations, water flow switches, and other applications
requiring the monitoring of dry contact devices. The
• UL 864 9th Edition Listed interrupt driven Digital Communications Protocol (DCP)
• Single input contact monitor combines maximum communication reliability and fast
response to emergency conditions. The DCP-FRCME-
• Fast, reliable contact monitoring utilizing the P contact monitoring module does not require a sepa-
Hochiki DCP (Digital Communications Protocol) rate 24 VDC power source.
• 127 devices can be used per DCP loop
• Can be programmed to monitor Normally Open Each addressable contact monitoring module is
(NO) or Normally Closed (NC) contacts programmed with its own unique Signaling Line
Circuit (SLC) loop address. The device address is
• Operates on Class A or Class B SLC loop electrically programmable and stored in onboard
EEPROM. Up to 127 devices can be placed on the
Hochiki DCP SLC loop. The module supervises the wiring
to the contact with an End Of Line (EOL) resistor. It can
be programmed to monitor Normally Open (NO) or
Normally Closed (NC) contacts. If a fault condition
occurs in the wiring, the module sends a trouble status
PRODUCT LISTINGS signal to the fire alarm control panel. When a change of
status (contact changes state) is sensed by the DCP-
California FRCME-P, it sends an interrupt to the control panel
State Fire indicating that an alarm has occurred.
Marshal
7300-0410:150
The DCP-FRCME-P is small design and is suitable for
S5694 mounting in a single gang box.
MEA
284-91-E Vol. IV
3022559
The contractor shall furnish and install where indicated on the plans, addressable contact monitoring modules
Hochiki DCP-FRCME-P. The modules shall be UL listed and compatible with the Hochiki Digital Communication
Protocol (DCP) supporting control panel. The device address shall be electrically programmable and stored in
EEPROM.
The DCP-FRCME-P shall fit inside a single gang electrical back box.
S (OUT)
FIRE ALARM EQUIPMENT
Red
0400-03180
SC CONTROL
1S80
S (IN)
For Mounting Position/Proper Installation,
DCP-FRCME-P
SER. NO. 910300001
For Dry Indoor Use Only
SC (OUT)
Blk
PANEL
see HA-06-195 Rev 02/11
SC (IN)
IN-A
Wht
S5694
IN-B
U.L. LISTED
ANY NUMBER OF UL LISTED N/O CONTACT CLOSURE E.O.L. DEVICE
DEVICES MAY BE USED . SUBJECT TO NFPA AND AHJ PART NUMBER
REQUIREMENTS. DO NOT MIX FIRE ALARM INITIATING 0400-03180
OR SUPERVISORY ON THE SAME MODULE
ALL CIRCUIT ARE SUPERVISED AND INHERENTLY POWER LIMITED
SPECIFICATIONS
Supply Voltage (S-SC) 25.3 ~ 39 VDC
Average Current 339μA (Typical)
Consumption 358μA (Alarm)
Programmable Input 1 Monitoring Inputs
EOL Device 10K Ohms Resistor
Max. Quantity Per Loop 127
Dimensions 1.75"W x 2.37"H x 0.5"D
Operating Temperature 32°F (0°C) 120°F (49°C)
Mounting 2" electrical box
Relative Humidity 90% RH Non-Condsensing
DESCRIPTION
The Hochiki DCP-FRCME-M Fast Response Contact
STANDARD FEATURES Monitoring Modules are designed to be used with pull
stations, water flow switches, and other applications
• UL 864 9th Edition Listed requiring the monitoring of dry contact devices. The
• Single input contact monitor interrupt driven Digital Communications Protocol (DCP)
combines maximum communication reliability and fast
• Fast, reliable contact monitoring utilizing the response to emergency conditions. The DCP-FRCME-
Hochiki DCP (Digital Communications Protocol) M contact monitoring module does not require a sepa-
• 127 devices can be used per DCP loop rate 24 VDC power source.
• Can be programmed to monitor Normally Open
(NO) or Normally Closed (NC) contacts Each addressable contact monitoring module is
• Operates on Class A or Class B SLC loop programmed with its own unique Signaling Line
• Accepts up to 12 AWG wire Circuit (SLC) loop address. The device address is
electrically programmable and stored in onboard
EEPROM. Up to 127 devices can be placed on the
Hochiki DCP SLC loop. The module supervises the wiring
to the contact with an End Of Line (EOL) resistor. It can
be programmed to monitor Normally Open (NO) or
Normally Closed (NC) contacts. If a fault condition
occurs in the wiring, the module sends a trouble status
signal to the fire alarm control panel. When a change of
status (contact changes state) is sensed by the DCP-
FRCME-M, it sends an interrupt to the control panel
PRODUCT LISTINGS indicating that an alarm has occurred.
California
State Fire The DCP-FRCME-M is a small design and is suitable
Marshal 3042214 for mounting in a single gang box.
S5694 7300-0410:150
The contractor shall furnish and install where indicated on the plans, addressable contact monitoring modules
Hochiki DCP-FRCME-M. The modules shall be UL listed and compatible with the Hochiki Digital Communication
Protocol (DCP) supporting control panel. The device address shall be electrically programmable and stored in
EEPROM.
The DCP-FRCME-M shall be suitable for mounting to a single gang electrical back box.
WIRING DIAGRAM
U.L. LISTED
COMPATIBLE
FIRE CONTROL
PANEL
E.O.L. DEVICE
PART NUMBER
0400-03180
NOTE: For Normally Closed (N/C) contact monitoring, the FRCME-M can only be used to generate a trouble
condition, not an alarm or supervisory.
NOTE: SLC Circuit is in reference to S, and SC for Class A/B wiring diagram.
NOTE: ANY NUMBER OF UL LISTED N/O CONTACT CLOSURE
DEVICES MAY BE USED, SUBJECT TO NFPA AND AHJ
REQUIREMENTS. DO NOT MIX FIRE ALARM AND SUPERVISORY
INITIATING DEVICES ON THE SAME MODULE.
The FRCMA/-I shall be supplied with a plastic face plate and shall be suitable for mounting to a 4" square or double
gang electrical back box. The FRCMA/-I shall provide a monitor LED that is visible through the face plate. FRCMA-I
shall provide a SCI LED that is visible through the face plate.
TB1 TB2
E.O.L. DEVICE
PART NUMBER
0400-03180
TB1 TB2
FIGURE 2B
The contractor shall furnish and install where indicated on the plans, the Hochiki DCP-SCI short circuit isolator. The
modules shall be UL listed compatible with Hochiki Digital Communications Protocol (DCP) supporting control panel
loops. The isolator module must be suitable for mounting in a standard 4" square electrical box or double gang. The
isolator module must provide a yellow LED for indication of status.
WIRING DIAGRAM
TB1
SER. NO. XXXXXXXXX
UL LISTED
SIGNALING DEVICE
ISSUE NO. AH-9774
(IN) S
DCP-SCI
(IN) SC
(OUT) SC
(OUT) S
COMPATIBLE
S5694
CONTROL
PANEL
TB1
SIGNALING DEVICE
ISSUE NO. AH-9774
LISTED
(IN) S
DCP-SCI
(IN) SC
(OUT) S
GROUP OF VARIOUS DCP MODULES
(OUT) SC
-
S5694
(OUT) SC
(OUT) S
(IN) SC
(IN) S
The contractor shall furnish and install where indicated on the plans, the Hochiki DCP-R2ML/H Series addressable
relay modules. The modules shall be UL listed compatible with Hochiki Digital Communications Protocol (DCP)
supporting control panel loops. The relay module must provide two Form C dry contacts rated as follows: R2ML - 2A
@ 30 VDC or 0.5A @ 120 VAC and R2MH - 8A @ 30VDC or 4.8A @ 250 VAC. The relay module must be suitable
for mounting in a standard 4" square electrical box. The relay module must provide a bi-colored LED for indication of
status. R2M-LI/-HI shall provide an SCI LED that is visible through the face plate.
COM1 SET 1
OUT_SC- POWER
LIMITED
NC2
FIGURE 1.
WIRING DIAGRAM
NON-SCI VERSION
FIGURE 2.
WIRING DIAGRAM
Hochiki America Corporation DCP-R2ML/-LI & DCP-R2MH/-HI Specifications subject to change without notice.
DIMM - DUAL INPUT MONITOR MODULE
SPECIFICATIONS
Supply Voltage (S-SC) 25.3 ~ 39 VDC
Average Current 600µA (Typical)
Consumption 720µA (Alarm)
Programmable Inputs 2 Independent Monitoring Inputs
EOL Device 22K ohms Resistor
Max. Quantity Per Loop 127
Dimensions 4.2”W x 4.7”H x 1.4”D
Operating Temperature 32°F (0°C) ~ 120°F (49°C)
Mounting 4” square electrical box
Relative Humidity 90% RH Non-Condensing
DESCRIPTION
STANDARD FEATURES
The Hochiki Dual Input Monitor Module (DIMM) is de-
• UL 864 9th Edition Listed signed for use on a UL listed Fire Alarm Control Panel.
• Fast, reliable contact monitoring utilizing the It provides two independent contact monitoring cir-
cuits while only utilizing one address on the SLC loop.
Hochiki DCP (Digital Communications Protocol) Up to 127 devices can be placed on a single SLC
• 127 devices can be used per DCP loop loop. The device address is uniquely stored on an
onboard EEPROM. The module can be programmed
• Bi-colored indicating LED provides module status
to monitor Normally Open (NO) or Normally Closed
• Dual input contact monitor (NC) contact fire alarm and supervisory devices. The
• Can be programmed to monitor Normally Open interrupt driven Digital Communication Protocol (DCP)
(NO) or Normally Closed (NC) contacts combines maximum communication reliability and
fast response to emergency conditions. The module
• Operates on Class A or Class B SLC loop has a single bi-colored LED to indicate device sta-
• Accepts up to 14 AWG wire tus. It fits into a standard 4" square or double gang
electrical back box.
PRODUCT LISTINGS
California
State Fire
Marshal
3033215
7300-0410:150
S5694
The contractor shall furnish and install where indicated on the plans, Hochiki DCP-DIMM addressable contact
monitoring modules. The modules shall be UL listed and compatible with the Hochiki Digital Communications
Protocol (DCP) supporting control panel loops. The device address shall be electrically programmable and stored in
EEPROM. The contact module must be suitable for mounting in a standard 4" square electrical box or double gang.
The contact module must provide a bi-colored LED to indicate device status.
WIRING DIAGRAM
SPECIFICATIONS
Supply Voltage (S-SC) 25.3 ~ 39 VDC
Auxiliary Supply Voltage 18.8 ~ 27.2 VDC
Average Current Consumption
(On S-SC Line) 670µA
2-Wire Detector Loop Current
Standby Detector Load 1mA Max.
From Auxiliary Supply 60mA Max.
EOL Device 4.7K ohms Resistor
Max. Quantity Per Loop 127
Alarm Threshold Level <1.5K ohms
Wiring Threshold Level >2.5K ohms & <6K ohms
Open Circuit Threshold Level >10K ohms
Max. 2-Wire Conventional
Detector (Loop Resistance) 50 ohms (total wire length)
STANDARD FEATURES Dimensions 4.2”W x 4.7”H x 1.4”D
Operating Temperature 32°F (0°C) ~ 120°F (49°C)
• UL 864 9th Edition Listed Mounting 4” square electrical box
• Provides an address point for a zone of up to 25
Relative Humidity 90% RH Non-Condensing
conventional smoke detectors
• Blinks green when polled. Latched on red (controlled
by panel) when activated
• Device address can be programmed with a DESCRIPTION
handheld programmer. Device address- ranges
from 1 to 127 The Hochiki Conventional Zone Module (DCP-CZM) is
designed for use on an analog addressable Fire Alarm
• Compatible with Class B and Class A wiring
system. Up to 127 devices can be placed on a single
• Auxiliary power source provides power for the zone
SLC loop. The device address is uniquely stored on an
of detectors
onboard EEPROM. The module allows the panel to
• Compatible with conventional detectors, SLR, SIJ, interface and monitor two-wire conventional detectors
SLK, SLV, DCD, DFE and SIH series or pull stations. Each DCP-CZM transmits the status
• Compatible with TH series linear heat cables from on one zone of devices (25 maximum per zone) back
Proline Protection Systems to the panel. It supervises the power supply as well
as the entire zone of devices. Status conditions are
reported as normal, open or alarm. All 2-wire smoke
PRODUCT LISTINGS detectors must be UL listed as compatible to be
interfaced with the DCP-CZM. The interrupt driven
California Digital Communication Protocol (DCP) combines
State Fire maximum communication reliability and fast response
Marshal to emergency conditions. The module has a single bi-
3033215
7300-0410:150 colored LED to indicate device status. It fits into a
S5694 standard 4" square or double gang electrical back box.
WIRING DIAGRAM
NFPA STYLE D WIRING DIAGRAM EXPLODED VIEW
3-4: CLASS A
24V- OUT+
UL LISTED 1481 -
24VDC + 24V+ For Dry Indoor Use Only
OUT-
REGULATED For Proper Mounting/Installation See
MAX. 25 CONVENTIONAL
POWER SUPPLY, HA-06-101 11/13 DETECTORS
LISTED FOR FIRE 24- 24V+
PROTECTION
NEXT DEVICE
WITH BATTERY ALL WIRING IS SUPERVISED AND POWER LIMITED.
BACKUP. EB
DO NOT MIX FIRE ALARM INITIATING, SUPERVISORY, OR
SECURITY DEVICES ON THE SAME MODULE.
FIGURE 3.
EXPLODED VIEW
NFPA STYLE B WIRING DIAGRAM
1-2: CLASS B
Compatible Two Wire Detectors for use with the CZM with zone identifier A:
Detector Model Detector Detector Type Base Model Base Max
Identifier Indetifier Detectors
SLK-24F HD-3 Photoelectric HSB-224 HB-53 25
SLK-24F HD-3 Photoelectric HSB-220 HB-56 25
SIH-24F HD-3 Ionization HSB-224 HB-53 25
SIH-24F HD-3 Ionization HSB-220 HB-56 25
SLR-24H HD-3 Photoelectric w/heat NS4-224, NS6-224 HB-5 25
SLR-24H HD-3 Photoelectric w/heat NS4-220, NS6-220 HB-3 25
SLR-24V HD-3 Photoelectric NS4-224, NS6-224 HB-5 25
SLR-24V HD-3 Photoelectric NS4-220, NS6-220 HB-3 25
SLR-835/-835W HD-3 NS4-224, NS6-224 HB-5 18
Photoelectric (8-35V)
NS4-224W, NS6-224W
SLR-835/-835W HD-3 Photoelectric (8-35V) NS4-220, NS6-220 HB-3 18
NS4-220W, NS6-220W
HD-5 Photoelectric (8-35V) NS4-224, NS6-224 HB-5 18
SLR-835H/-835HW
w/thermal NS4-224W, NS6-224W
HD-5 Photoelectric (8-35V) NS4-220, NS6-220 HB-3 18
SLR-835H/-835HW
w/thermal NS4-220W, NS6-220W
SLR-835B-2/-2W HD-6 Photoelectric (8-35V) (baseless) N/A N/A 18
SLR-835BH-2/-2W HD-6 Photoelectric (8-35V) N/A N/A 18
w/thermal (baseless)
SIJ-24 HD-3 Ionization NS4-224, NS6-224 HB-5 25
SIJ-24 HD-3 Ionization NS4-220, NS6-220 HB-3 25
DCD-135/-190 HD-3 Heat Fixed Temp/Rate of Rise NS4-224, NS6-224 HB-5 25
DCD-135/-190 HD-3 Heat Fixed Temp/Rate of Rise NS4-220, NS6-220 HB-3 25
DFE-135/-190 N/A Heat Fixed Temp HSC-224L HB-62 25
DFE-135/-190 N/A Heat Fixed Temp HSC-220L HB-64 25
SLV-24/-24N/-24V HD-3 Photoelectric NS4-224, NS6-224 25
NS4-224W, NS6-224W HB-5
SLV-24/-24N/-24V HD-3 Photoelectric NS4-220, NS6-220 25
NS4-220W, NS6-220W HB-3
Compatible Linear Heat Detection Cable for use with the CZM:
Manufacturer Model Description Maximum Lenght
Proline Protection Systems TH 68 Fixed Temp. line type heat detector cable 155 F (68 C) 8,000ft. (2,438m)
Proline Protection Systems TH 88 Fixed Temp. line type heat detector cable 190 F (88 C) 8,000ft. (2,438m)
Proline Protection Systems TH 105 Fixed Temp. line type heat detector cable 221 F (105 C) 8,000ft. (2,438m)
SPECIFICATIONS
Supply Voltage 17 ~ 41 VDC
Current 7mA (Alarm)
Consumption
Dimensions 2.73”W x 4.5”H x 0.15”D
Operating 32°F (0°C) ~ 120°F (49°C)
Temperature
Relative Humidity 90% RH Non-Condensing
Environment For Dry Indoor Use Only
Mounting Single gang electrical box
Compatible Bases HSB-NSA-6, YBN-NSA-4,
ASB, SCI-B4, SCI-B6
Compatible AIE-EA, ALG-V, ALK-V, ATG-
Detector/Sensors EA, ACA-V
RAI-LED
STANDARD FEATURES
• UL Listed
• Compatible with analog addressable detectors,
sensors and bases
• Compatible with FireNET 2127/4127 and
FireNET Plus FACPs
DESCRIPTION
PRODUCT LISTINGS
California
State Fire
Marshal Pending
S3516 7300-0410:0201
STANDARD FEATURES
PRODUCT LISTINGS
California
State Fire
Marshal
7165-0410:183
BASES
NS6-224 6" base, 43mA draw, 24V 20
NS4-224 4" base, 43mA draw, 24V 20
NS6-100 6" base, 150mA draw, 24V 20
NS4-100 4" base, 150mA draw, 24V 20
PULL STATION
HPS-SAK/HPS-DAH Conventional Manual Pull Station 25
HPS-SAH/HPS-DAK Conventional Manual Pull Station
RELEASING ACCESORY
0400-02590 Releasing EOL Module (Included for HCA-4, -8) 1
PB-SA Abort Switch 1
HPS-DAK-SR Fire Suppression Release Pull Station 1
Hochiki America Corporation HCA Series CONVENTIONAL FIRE ALARM CONTROL PANEL Specifications subject to change without notice.
HCP-1008E FIRE ALARM CONTROL PANEL
DESCRIPTION
Hochiki’s HCP-1008E Fire Alarm Control Panel is a
microprocessor based unit designed for maximum flexibility
and easy installation. Fully configurable from the front
panel using the push buttons and DIP switches, it enables
the user to configure the system to meet their specific
requirements.
The HCP-1008E consists of one HMCC-1024-6 main
Chassis in an HBB-1024 Enclosure. The HMCC1024-6
main Chassis comes complete with 8 Class B (Style B)
initiating circuits which may be configured as 4 Class A
(Style D) circuits. It can be expanded up to 24 Class B or
12 Class A circuits with the addition of two HDM-1008
Initiating Circuit Modules. In addition it comes equipped
with 4 Class A/B (Style Z/Y) indicating circuits which are
each rated at 1.7 Amps. The main Chassis also includes
a 6 amp power supply which powers the system and
supplies two 4-wire resettable regulated smoke power
supply of 24 VDC 200mA maximum each. The HMCC-
STANDARD FEATURES 1024-6 also allows for the addition of two HSGM-1004
• 8 Class B (Style B) initiating circuits which may Signal Modules or two HRM-1008 Relay Modules in place
be configured as 4 Class A (Style D) circuits of the HDM-1008 Initiating Circuit Adder Modules.
Expandable up to 24 Class B or 12 Class A (Maximum of 2 adder modules and 1 communication
initiating circuits module).
• 4 Class A/B (Style Z/Y) indicating circuits with The cabinet is available in a beige color for the Canadian
individual trouble indicators (1.7 Amps max. per market and a red exterior for the U.S. and international
circuit) markets. A Fire Retardant Lexan Window in the hinged
• Each indicating circuit can be configured as door allows for viewing of the status LEDs. It comes with
silenceable or non-silenceable. Audibles may be a durable CAT-30 lock and key. Space is provided for up
configured as Steady, Temporal Code, California to 17 AH Gel Cell batteries.
Code or March Time
Hochiki's HCP-1008E is designed as an economical
• Each initiating circuit can be configured as alarm, Microprocessor Based Fire Alarm Control Panel which is
supervisory, waterflow or trouble expandable up to 24 display points. Its modular design
• Two outputs for 4 wire resettable smoke power suits various applications. Ideal for applications such as
supply (200 mA Max. each) small institutional and commercial buildings, shopping
• Alarm verification on initiating circuits malls, offices and public establishments, the HCP-1008E
is configurable to meet virtually all requirements. The panel
• Easy configuration via push buttons and DIP
is designed to be easy in its installation, operation and
switches on the front panel
maintenance. This makes the system cost effective and
SPECIFICATIONS very reliable for its intended applications.
Primary Input Power 120 volts, 60 Hz, 1 Amps
(Optional 220 - 240VAC) PRODUCT LISTINGS
Indicating Current 24VDC unfiltered, 5Amps California
Standby Power 24VDC standby batteries State Fire
Charging Capability 10 – 24 AH batteries Marshal
S6468 7165-0410:154
Dimensions 26"H x 14 1/2"W x 4 1/2" D
Model Description
Fire Alarm Control Panel
HCP-1008E Microprocessor Based Fire Alarm Control Panel expandable up to 24 display points.
Includes HMCC-1024-6 main Chassis complete with 8 Class B (Style B) initiating circuits
or 4 Class A (Style D) initiating circuits, 4 Class A/B (Style Z/Y) indicating circuits, 6 amp
power supply and one HBB-1024 Red Enclosure. (DIP switches)
HCP-1008ES Microprocessor Based Fire Alarm Control Panel expandable up to 24 display points.
Includes HMCC-1024-6S main Chassis complete with 8 Class B (Style B) initiating
circuits or 4 Class A (Style D) initiating circuits, 4 Class A/B (Style Z/Y) indicating circuits,
6 amp power supply and one HBB-1024 Red Enclosure. (Slide switch version)
HFA-1024TR Semi-Flush Trim Ring
HRTI-1 Remote Trouble Indicator
Adder Modules
HDM-1008 Eight Class B (Style B) or 4 Class A (Style D) Initiating Circuit Module
HSGM-1004 Four Class A/B (Style Z/Y) Indicating Circuit Module (Rated at 1.7 Amps per circuit).
HRM-1008 Eight Relay Circuit Module comes with eight Form C relays (Rated for 28 VDC @ 1 Amp.
max. per relay)
Auxiliary Modules
HDACT-100U Universal Digital Alarm CommunicationTransmitter/Dialer Module
HDACT-100 Digital Alarm Communication Transmitter/Dialer Module
HPR-100 Polarity Reversal and City Tie Module
Remote Annunciator
HRAM-1032 Main Annunciator Chassis comes with common control features, indicators and 32
bi-colored LEDs
HBB-1001 Annunciator backbox with keylock door
Hochiki America Corporation • HCP-1008E Fire Alarm Control Panel Specifications subject to change without notice.
HRA-1000 REMOTE ANNUNCIATORS
HRAM-1032- Main Annunciator Chassis
1.2"
#6-32
HEXNUTS
BB-1001 BACKBOX IS SHOWN
ANNUNCIATOR CHASSIS
ORDERING INFORMATION
Model Description
Modules
HRAM-1032 Main Annunciator Chassis comes with Common Control Features, Indicators and 32 Bi-Colored
LEDs
HRAX-1048 Adder Annunciator Chassis comes with 48 Bi-Colored LEDs
Backboxes
HBB-1001 Annunciator backbox with keylock door (Houses 1 module)
HBB-1002 Annunciator backbox with keylock door (Houses 2 modules)
HBB-1003 Annunciator backbox with keylock door (Houses 3 modules)
Hochiki America Corporation • HRA-1000 Remote Annunciators Specifications subject to change without notice.
Series HPS-SAH, HPS-SAK, HPS-DAH, HPS-DAH/S, HPS-DAK, HPS-DAK/S
Manual Non-Coded Pull Station
STANDARD FEATURES
• Metal Construction
• Enclosed switch with glass rod (included)
• 10 Amps @ 120 VAC
• Available in: Single Action, Dual Action and
Dual Action in Spanish (HPS-DAH/S)
• UL, CSFM Listed
• Made in USA
HPS-SAH HPS-SAK
DESCRIPTION
PRODUCT LISTINGS
California
State Fire
Marshal
7150-0410:162
S6512
HPS-DAK HPS-DAK/S
Continued on back.
PULL DOWN
SPECIFICATION
ELECTRICAL WIRING
Hochiki America Corporation Series HPS-SAH, HPS-SAK, HPS-DAH, HPS-DAH/S, HPS-DAK, HPS-DAK/S Specifications subject to change without notice.
HPS-SAH-WP Weather Proof Manual Pull Stations
DESCRIPTION
The Hochiki HPS-SAH-WP Weatherproof Manual Pull
Station is a UL Listed fire alarm initiating device
suitable for applications requiring outdoor mounting of
the manual fire alarm pull station. The HPS-SAH-WP
is appropriate for applications where the manual pull
station may be subject to wet conditions.
SPECIFICATIONS
Model HPS-SAH-WP Pigtails
Contact (1) Form A
Contact Rating 10A @ 120 VAC
Operating Temperature -30°F (-35 °C) ~ 150°F (66°C)
HPS-BB Dimension 1-3/4" Backbox
PRODUCT LISTINGS
California
State Fire
Marshal
7150-0410:162
S6512
SPECIFICATIONS
Model HPS-DAK-WP
Contact (1) Form A
Contact Rating 10A @ 120 VAC
Operating Temperature -30°F (-35 °C) ~ 150°F (66°C)
SPECIFICATIONS
Model HPS-DAK-SR
Contact (1) Form A
Contact Rating 10A @ 120 VAC
Operating Temperature -30°F (-35 °C) ~ 150°F (66°C)
STANDARD FEATURES
• Metal Construction
• Enclosed switch with glass rod (included)
• UL, CSFM Listed
• Made in USA
DESCRIPTION
PRODUCT LISTINGS
California
State Fire
Marshal
7150-0410:162
S6512
DESCRIPTION
WIRING DIAGRAM
TOP REAR VIEW
HPS-CP/S
L1
IN INITIATING
L2
CIRCUIT
STANDARD FEATURES L2 OUT
L1
2-WIRE OPERATION
UL LISTED
CONTROL LISTED
PANEL END OF LINE
DEVICE
HSC-RELAY SERIES
ORN
N/O 3 PUR
INITIATING LISTED
CIRCUIT END OF LINE
DEVICE
HSC-4R
CONTACTS
H1
H2
YEL
ORN
PUR
UL LISTED LISTED
POWER END OF LINE
SUPPLY RELAY
12VDC OR 24VDC HA-EOLR-12 OR HA-EOLR-24
HSC-4R HSC-4R
Hochiki America Corporation SLR-24V Specifications subject to change without notice.
SLR-24VN PHOTOELECTRIC SMOKE DETECTOR
APPLICATIONS
The SLR-24VN can be used in all areas where Photo-
electric Smoke Detectors are required. The wide range
smoke chamber makes the SLR-24VN (w/o Reed Switch
model) well suited for fires ranging from smoldering to
flaming fires.
The smoke detector shall have two flashing status LEDs for visual supervision. When the detector is in standby condition the
LEDs will flash Green. When the detector is outside the UL listed sensitivity window the LEDs will flash Red. When the detector
is actuated, the flashing LEDs will latch on Red. The detector may be reset by actuating the control panel reset switch.
The sensitivity of the detector shall be capable of being measured. The sensitivity of the detector shall be monitored automati-
cally and continuously to verify that it is operating within the listed sensitivity range.
To facilitate installation, the detector shall be non-polarized. Voltage and RF transient suppression techniques shall be employed
to minimize false alarm potential. Auxiliary SPDT relays shall be installed where indicated.
The base shall permit direct interchange with Hochiki America SLR-24V photoelectric detector, SIJ-24 ionization type
smoke detector and/or DCD-135/190 fixed temperature/rate-of-rise heat detectors. The base shall be appropriate twist-
lock base NS-4 Series, NS-6 Series, HSC-4R, or HSC-xxx R. In the event of partial or complete retrofit, the SLR-24
maybe used in conjunction with, or as a replacement for, Hochiki America detectors (SLK-24, SLK-24FH and the SIH-
24) on most HSB and HSC base applications.
The smoke detector shall have two flashing status LED's for visual supervision. When the detector is in standby
condition the LED's will flash Green. When the detector is outside the UL listed sensitivity window the LED's will flash
Red. When the detector is actuated, the flashing LED's will latch on Red. The detector may be reset by actuating the
control panel reset switch.
The sensitivity of the detector shall be capable of being measured. It shall be possible to perform a functional test of the
detector without the need of generating smoke. The sensitivity of the detector shall be monitored automatically and
continuously to verify that it is operating within the listed sensitivity range.
To facilitate installation, the detector shall be non-polarized. Voltage and RF transient suppression techniques shall be
employed to minimize false alarm potential. Auxiliary SPDT relays shall be installed where indicated.
The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking
feature shall be field removable when not required.
HSC-4R HSC-4R
2-WIRE OPERATION
UL LISTED (+)
CONTROL LISTED
PANEL END OF LINE
DEVICE
(-)
PANEL Resistor shown is for example
POWER only. Not all annunciators have
in line resistance.
SUPPLY
(-) NOTE: - WIRING TERMINALS FOR THE NS4
NEGATIVE AND NS6 ARE IDENTICAL
NS4 SERIES NS6 SERIES - BASES WITH THE "W" SUFFIX
Annunciation device must be current limited to 20 mA @ ARE WHITE IN COLOR
24VDC Maximum. Not limiting current could result in
damage to the detector or cause a no alarm condition.
4-WIRE OPERATION
INITIATING LISTED
CIRCUIT END OF LINE
DEVICE
HSC-4R
CONTACTS
H1
H2
YEL
ORN
PUR
UL LISTED
POWER
SUPPLY LISTED
24VDC END OF LINE
RELAY
HA-EOLR-24
HSC-4R HSC-4R
2-WIRE OPERATION
UL LISTED
CONTROL LISTED
PANEL END OF LINE
DEVICE
HSC-(XXX)R (2-WIRE)
COM 6
N/C 5 GRY
BLU
GRN
N/O 4 YEL
ORN
HSC-RELAY SERIES N/O 3 PUR
California
State Fire
3007144 Marshal
7272-0410:107
S1383
Specifications subject to change without notice.
Continued on back.
ENGINEERING SPECIFICATIONS
The contractor shall furnish and install where indicated on the plans HOCHIKI America SLR-835B direct-wire photoelectric
smoke detectors. The detector shall be UL listed compatible (2-wire model) with a UL listed fire alarm panel.
The smoke detector shall have green flashing status LED's for visual supervision. When the detector is actuated, the
flashing LED's will turn red and latch on steady. The detector may be reset by actuating the control panel reset switch.
The detector shall have a sensitivity window verification feature. If the sensitivity of the detector drifts outside its
approved window the LED's will flash red to indicate an out of sensitivity condition.
The vandal resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking
feature shall be field selectable.
It shall be possible to perform a functional test of the detector without the need of generating smoke. The method shall
simulate effects of products of combustion in the chamber to ensure testing of detector circuits.
Voltage and RF transient suppression techniques shall be employed to minimize false alarm potential.
WIRING DIAGRAMS
2-Wire Wiring Diagram
U.L. Listed
Power
Supply
*24VDC Listed
End-of-Line
Relay
12 or 24VDC
U.L. Listed
Power
Supply
*12VDC
* Use either 12 OR 24VDC . They cannot be used simultaneously.
The smoke detector shall have flashing status LED for visual supervision. When the detector is actuated, the flashing
LED will latch on steady at full brilliance. The detector may be reset by actuating the control panel reset switch.
The vandal resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking
feature shall be field selectable.
It shall be possible to perform a functional test of the detector without the need of generating smoke. The method shall
simulate effects of products of combustion in the chamber to ensure testing of detector circuits.
Voltage and RF transient suppression techniques shall be employed to minimize false alarm potential.
WIRING DIAGRAMS
U.L. Listed
Power 24VDC 12VDC C NO 24VDC 12VDC C NO
Supply
*24VDC Listed
End-of-Line
Relay
12 or 24VDC
U.L. Listed
Power
Supply
*12VDC
* Use either 12 OR 24VDC . They cannot be used simultaneously.
APPLICATION
The SLV-24M is for use in enclosed spaces, for
ceiling-mount installations only and for use in
enclosed dry cabin locations, where the unit is
protected against blowing, spraying, and dripping
water. The patented smoke chamber makes the
SLV-24M well suited for fires ranging from smoldering
to flaming fires.
NS4-220 (Marine Type) and NS6-220 (Marine Type)
bases are used with the SLV-24M.
The contractor shall furnish and install where indicated on the plans, Hochiki America Model SLV-24M marine photo-
electric smoke detectors. The combination detector head and twist-lock base shall be UL listed compatible with a UL
listed fire alarm panel.
The base shall be appropriate twist-lock base NS4-220 (Marine Type) and NS6-220 (Marine Type).
The smoke detector shall have two flashing status LEDs for visual supervision. When the detector is in standby
condition the LEDs will flash Green. When the detector is actuated, the flashing LEDs will latch on Red. The detector
may be reset by actuating the control panel reset switch.
The sensitivity of the detector shall be capable of being measured.
To facilitate installation, the detector shall be non-polarized. Voltage and RF/transient suppression techniques shall be
employed in the detector to minimize false alarm potential.
The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking
feature shall be field removable when not required.
WIRING DIAGRAM
UL LISTED
CONTROL LISTED
PANEL END OF LINE
DEVICE
NEGATIVE
NS4-220 NS6-220
Annunciation device must be current limited to 20 mA @
24VDC Maximum. Not limiting current could result in
damage to the detector or cause a no alarm condition.
Contact Rating
(0°C to 49°C)
N/O Contacts MEA
284-91E Vol. IV
150mA max. @ 24 V
Color & Case Material Bone PC/ABS blend 1D5A1.AY
California
Mounting Refer to the NS Conventional State Fire
Detector Base Data Sheet S2966 Marshal
7270-0410:151
Automatic heat detectors where ambient temperatures do not exceed 120°F shall be the DCD-135 fixed temperature/
rate-of-rise heat detector rated at 135°F. For areas where ambient temperatures exceed 120°F, but not 160°F, the
DCD-190 fixed temperature/rate-of-rise heat detector rated at 190°F shall be used. Electrical contacts shall be
normally open, rated at 150mA @ 24VDC.
Heat detectors shall be installed in accordance with National Fire Protection Association Standard 72, the spacing
assigned by Underwriters Laboratories and in accordance with the rules and regulations set forth by the local authorities
having jurisdiction. Automatic heat detectors shall be Underwriters Laboratories listed.
4-WIRE OPERATION
(+)
INITIATING LISTED
CIRCUIT END OF LINE
DEVICE
HSC-4R
CONTACTS
(-) H1
H2
YEL
ORN
PUR
HSC-4R HSC-4R
2-WIRE OPERATION
UL LISTED (+)
CONTROL LISTED
PANEL END OF LINE
DEVICE
(-)
PANEL Resistor shown is for example
POWER only. Not all annunciators have
in line resistance.
SUPPLY
(-)
NEGATIVE
NS4 SERIES NS6 SERIES
Annunciation device must be current limited to 20 mA @
24VDC Maximum. Not limiting current could result in
damage to the detector or cause a no alarm condition.
(+)
UL LISTED LISTED
CONTROL END OF LINE
PANEL DEVICE
TERMINAL BLOCK USED ON
HSC-224RA/RST VERSION ONLY
(-) HSC-(XXX)R (2-WIRE)
COM 6
GRY
N/C 5 BLU
GRN
N/O 4 YEL
ORN
HSC-RELAY SERIES N/O 3 PUR
OPERATION
STANDARD FEATURES The DFE 135/190 fixed temperature heat detector is
suited to alarm in the presence of slowly rising
• Choice of fixed temperature - 135°F or 190°F temperatures. The construction of this model
• UL Listed ceiling spacing of 50' by 50' incorporates an oversized heat collector protected from
damage by the built-in, durable plastic guard. The DFE
(2,500 square feet) 135/190 fixed temperature heat detector used the proven
• Self-Restoring snap-disc principle of operation. This bi-metal disc
deflects when temperature reaches a predetermined
• Heat element protected by a built-in guard value. The disc deflection then causes a push-rod to
• Contact Rating of 100 mA close the internal contact resulting in an alarm condition.
The bi-metal disc returns to its normal shape when the
• Highly Dependable heat subsides causing internal contacts to return to their
normally open position. A standby condition is restored.
• Latching LED base available
SPECIFICATIONS
Response Temperature 135° ± 7.5°F
ENGINEERING SPECIFICATIONS
Temperature 190° ± 7.5°F Automatic heat detectors shall be fixed temperature rated
Contact Rating N/O Contacts at 135°F for areas where ambient temperatures do not
100mA @ 60 V exceed 120°F and 190°F where ambient temperatures
Maximum Humidity 95% RH Non-Condensing exceed 120°F but not 160°F. The fixed temperature el-
Color & Case Material Ivory ACS ement shall consist of a bi-metallic disc and actuator
Mounting Refer to back of this sheet shaft. Electrical contacts shall be normally open, rated
at 100mA @ 60VDC.
PRODUCT LISTINGS
Heat detectors shall be installed in accordance with
National Fire Protection Association Standard 72, the
California
State Fire MEA spacing assigned by Underwriters Laboratories, and in
accordance with the rules and regulations set forth by
284-91E Vol. II
Marshal the local authorities having jurisdiction. Automatic heat
7270-0410:119 detectors shall be Underwriters Laboratories listed.
S2966
Specifications subject to change without notice. Continued on back.
The HSC-xxx L Series is a 6" base featuring a current limiting resistor, latching annunciator output
and a latching circuit so the alarm LED will remain lit until the control panel has been reset. Heat
detectors are not recognized as proper detection for life safety protection, therefore they should
be utilized only for the protection of property.
COMPATIBLE (+)
UL LISTED LISTED
CONTROL END OF LINE
PANEL DEVICE
3.9K 1/2W
(-)
Pig Tail Lead
PANEL
POWER (-)
SUPPLY
HSC-(XXX)L SERIES
NEGATIVE
Nominal alarm current shown at 24V. Polarized with annunciator output.
HSC-21L 24mA HSC-221L 41mA
HSC-224L 38mA HSC-220L 73mA
California
State Fire
Marshal
7270-0410:0178
Specifications subject to change without notice. S2966
Continued on back.
The HSC-(XXX)L Series is a 6" base featuring a current limiting resistor, latching annunciator
output and a latching circuit so the alarm LED will remain lit until the control panel has been
reset. Heat detectors are not recognized as proper detection for life safety protection, therefore
they should be utilized only for the protection of property.
COMPATIBLE (+)
UL LISTED LISTED
CONTROL END OF LINE
PANEL DEVICE
3.9K 1/2W
(-)
Pig Tail Lead
PANEL
POWER (-)
SUPPLY
HSC-(XXX)L SERIES
NEGATIVE
The NS6-100 is a 6" diameter base that has no current limiting nor annunciator output features.
A direct short occurs across the loop when the detector is actuated. Heat detectors are not
recognized as proper detection for life safety protection, therefore they should be utilized only
for the protection of property.
(+)
COMPATIBLE
UL LISTED LISTED
CONTROL END OF LINE
PANEL DEVICE
(-)
6 6
NS6-100
Non polarized, not current limited. No annunciator output.
We try to keep our product information up-to-date and accurate. However, we cannot cover
all specifications or anticipate all requirements. For additional information contact
your local distributor or call or write Hochiki America Corporation.
ENGINEERING SPECIFICATIONS
The contractor shall furnish and install, where indicated on the plans, Hochiki America SPC-24 Projected Beam Smoke
Detector. The projected beam smoke detector shall have a range of 32.8 feet to 328 feet. The projected beam smoke
detector shall be field adjustable to one of the three obscuration settings of 25%, 50% or 70% per span. These settings
shall be capable of being verified with calibrated filters. Side to side spacing shall be a maximum of 60 feet on center.
The projected beam smoke detector shall possess circuitry that automatically compensates for normal ambient changes
in the intensity of the emitted beam strength. The microprocessor shall provide compensation for a change in received
signal value, with time, caused by contamination of the optics. Since such a change with time appears as a slow change
in the beam signal, the microprocessor shall compensate in such a manner that the signal moves closer to the reference
data at a rate of approximately +1% per hour. When this compensating capability reaches a limit, the microprocessor
shall automatically generate a trouble signal.
The projected beam smoke detector(s) shall also signal a trouble condition if the beam has a blockage of 90% or more for
more than 9 seconds and automatically resets to normal when blockage is removed.
The projected beam smoke detector(s) shall be UL listed for these applications. Voltage and RF transient protection shall
be integral to the internal circuitry of the projected beam smoke detector so as to minimize false alarm potential.
To facilitate easy installation and setup, the projected beam smoke detectors shall employ signal strength indicating
LED's. Alignment shall be facilitated by turning an alignment adjustment wheel and monitoring the relative signal strength
based upon which LED's are illuminated.
The detectors shall also illuminate a red LED, which is visible externally, when an alarm condition is indicated.
The projected beam smoke detector shall provide a Form "A" dry contact for alarm and Form "B" dry contact for trouble.
INSTALLATION
The HOCHIKI America SPC-24 Projected Beam Smoke Detector shall be installed in accordance with the Installation
Instruction Guide provided with every unit. Refer to the applicable NFPA Standards for additional guidance on spacing,
irregular ceiling surfaces and other design considerations.
24V + E1 E1 E1 E1
24V - E2 E2 E2 E2
Emitter Emitter
EOL-24
Receiver Receiver
End of Line
24V + 24V 24V 24V 24V Resistor
24V - 0V 0V 0V 0V
F1 F1 F1 F1
Zone +
Zone - F2 F2 F2 F2
T1 T2 T1 T2
Control
Panel
Ceiling
#1
120°
2m
#2
3m
Ceiling Height
4m
5m
6m
7m
8m
Floor
WIRING DIAGRAMS
PANEL
POWER (-)
SUPPLY
HSB-2 Wire
UL LISTED
CONTROL
(+)
PANEL
LISTED
END OF LINE
DEVICE
(-) 3.9K 1/2W
PANEL
POWER 16mA MAX.
SUPPLY OUTPUT
(-) 16mA MAX.
OUTPUT
NEGATIVE CURRENT LIMTED AT 24VDC
Trouble Contacts 1 Form "C" rated at 10 amps 1 Form "C" rated at 10 amps
@ 125VAC @ 250VAC
The DH-98 is designed and built to meet all local
Sensitivity Test Method Self Diagnostic Self Diagnostic
Test Test requirements, as well as the NFPA regulations regarding
Remote Indication Capability Power, Alarm, Power, Alarm, duct smoke detectors. Output terminals are provided for
(Refer to DH-98 Accessories Horn/Piezo, Horn/Piezo,
Data Sheet for Specifications) Test Test remote accessories such as a horn, strobe, remote status
Air Velocity 300 to 4000 ft./min
indicators and reset key switches or push buttons.
Ambient Temperature 32°F to 100°F (0°C to 38°C)
The compact DH-98 contains 3 sets of alarm contacts; 1 set of form “C” contacts rated at 10 amps, 1 set of form “A”
contacts rated at 10 amps and 1 set of form “A” contacts rated at 1 amp. There is also 1 set of form “C” 10 amp trouble
contacts for monitoring detector head removal, and the failure of the input supply voltage.
The pilot and alarm visual indicators provided on the front of the DH-98 duct unit signal the operating status of the
device. A manual test/reset switch is located along side the visual indicators.
ENGINEERING SPECIFICATIONS
Air duct smoke detectors shall be HOCHIKI AMERICA DH-98 Series. The detectors shall be listed by Underwriters
Laboratories per UL 268A. The detectors shall operate at air velocities from 300 feet per minute to 4000 feet per minute.
The detectors shall have the ability to interconnect up to 30 units using the same independent power supply.
The duct detector housings shall be of metal construction and complete mechanical installation may be performed
without removal of the detector cover. Visual indication of alarm and power must be provided on detector front. A manual
reset switch shall be located on the front of the device. Detector heads shall not require additional filters or screens
which must be maintained. The housing shall contain a detector base which will accept photoelectric or ionization
detector heads. Terminal connections shall be of the screw type and be a minimum of # 6 screw. Terminals shall be
provided for remote pilot, remote alarm indication, strobe/horn and remote key switch. All wiring must comply with local
codes and regulations.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
* T ro u b le c o n tac ts a re sh o w n in n o n -e n e rg ize d
c o n d itio n . T ro u b le c o n tac ts m o n ito r p o w e r
D H -9 8 D U C T S M O K E D E T E C T O R c o n n e c te d a n d h e a d re m o v ed .
- +
1 2 3 4 5 6 1 2 3 4 5 6
D H -9 8 -P
-I D H --9988 -P
2 4 V .A . C . O P E R A T IO N 2 4 V .D .C . O P E R A T I O N
1 1 5 V A C 6 0 H z IN P U T 2 3 0 V A C 6 0 H z IN P U T
@ 0 .1 A M P M A X . @ 0 .1 A M P M A X .
G N H G N H
1 2 3 4 5 6 1 2 3 4 5 6
D H -9 8 -P
-I D H -9 8 -H V P
I
1 1 5 V .A .C . O P E R A T IO N 2 3 0 V . A . C . O P E R A T IO N
INPUT
P
POWER
P
Hochiki America Corporation DH-98 Conventional Specifications subject to change without notice.
DUCT DETECTOR REMOTE ACCESSORIES
APPLICATION SPECIFICATIONS
The Duct Detector Remote Accessories are designed Power Requirements
to be used with the DH-98 Conventional and DH-98/ Alarm LED 15 mA
DH-99 Analog Duct Detectors to provide audible and Pilot LED 15 mA
visual indication as well as remote test/reset functions. Horn 20 mA @ 24 VDC
Sound Pressure
These devices are contructed of brushed stainless Horn 78 db @ 10 feet
steel and mount on a standard single or double gang Dimensions
backbox. Single Gang 2.75" (69.85mm) W
4.5" (114.3mm) H
Double Gang 4.5" (114.3mm) W
4.5" (114.3mm) H
MS-RA MS-KA/P/R
Functions: Functions:
Remote Alarm LED (red) ALARM
Remote Alarm LED (red)
For Use with: Pilot LED (green)
ALARM
DH-98-I, DH-98-P PILOT
Key-Operated Test/Reset
DH-98-HVI, DH-98-HVP Switch
DH-98-AR, DH-99-AR For Use with:
TEST/RESET
DH-98-I, DH-98-P
DH-98-HVI, DH-98-HVP
MS-KA/R MS-RA/R
Functions: Functions:
ALARM Remote Alarm LED (red) Remote Alarm LED (red)
Key-Operated Test/Reset ALARM
Push-button Test/Reset
Switch Switch
For Use with: For Use with:
DH-98-I, DH-98-P TEST/RESET DH-98-I, DH-98-P
TEST/RESET
DH-98-HVI, DH-98-HVP DH-98-HVI, DH-98-HVP
DH-98-AR, DH-99-AR DH-98-AR, DH-99-AR
MS-RA/P MS-RA/P/R
Functions: Functions:
Remote Alarm LED (red) Remote Alarm LED (red)
ALARM
ALARM Pilot LED (green) Pilot LED (green)
For Use with: Push-button Test/Reset
PILOT
DH-98-I, DH-98-P Switch
PILOT DH-98-HVI, DH-98-HVP For Use with:
TEST/RESET DH-98-I, DH-98-P
DH-98-HVI, DH-98-HVP
WIRING DIAGRAM
RED
RED
RED GREEN
ALARM
24VDC PILOT
24VDC ALARM HORN
LED LED
BLACK
BLACK
ALARM
PILOT
BLACK
KEY OR
PUSH BUTTON
24VDC
"TEST/RESET"
SWITCH
BLACK
TEST/RESET
PRODUCT SPECIFICATIONS
PUSH KEY
PILOT ALARM BUTTON OPERATED
LED LED TEST/ TEST/ SINGLE DOUBLE
(GREEN) (RED) RESET RESET HORN GANG GANG
MODEL #
MS-RA
MS-RA/P
MS-RA/R
MS-RA/P/R
MS-KA/R
MS-KA/P/R
MS-RH/KA/P/R
Hochiki America Corporation Duct Detector Remote Accessories Specifications subject to change without notice.
Conventional Detector Bases
NS6 AND NS4 SERIES BASE
The NS6 and NS4 Series is designed specifically for use with
HOCHIKI Conventional Models SIJ-24 Ionization Smoke Detector,
SLR-24V Photoelectric Smoke Detector, SLV-24, SLV-24N, SLV-24V
Photoelectric Smoke Detectors, SLR-24H Photoelectric with Heat
Smoke Detector, SLR-835 Photoelectric Smoke Detector, SLR-835H
Photelectric Smoke Detector w/heat, or DCD-135/190 Fixed
Temperature/Rate-of-Rise Heat Detector. The Base is an electronics
NS Series Bases Alarm Curr ent ID
free 6" base featuring a plastic tamper-lock lug. Each base is
NS6-224 O R N S4-224 43mA (70mA @ 33.0V MAX) HB-5
equipped with a resistor. Refer to the chart (left) for additional
NS6-220 O R N S4-220 93mA (136mA @ 33.0V MAX) HB-3
specifications. The NS4 base is a 4" version of the NS6 base.
NS6-221 O R N S4-221 46mA (77mA @ 33.0V MAX) HB-4
NS6-100* O R NS4-100* 150mA @ 15.0 – 33.0V MAX) HB-55
*Requires external current ext ernal limiting to 150mA maximum Models HSC-224R, HSC-220R and the HSC-221R are designed
specifically for use with the HOCHIKI Conventional Models SIJ-24,
HSC- (X)R RELAY BASE & SLR-24V, SLR-24H, SLV-24, SLV-24N, SLV-24V, SLR-835, SLR-
HSC- 4R 4 WIRE BASE 835H or DCD-135/190. The HSC-(X)R series is a 6" base with two
sets of Form "C" relay contacts.
Models HSC-224R, HSC-220R and the HSC-221R are also
approved for use with HOCHIKI previous Conventional Models
SIH-24F, SLK-24F, SLK-24FH and the DFE 135/190.
The HSC-4R is designed specifically for 24 volt 4 wire applications
using HOCHIKI Conventional Models SIJ-24, SLR-24V, SLR-24H,
SLV-24, SLV-2N, SLV-24V, SLR-835, SLR-835H or DCD-135/190. The
6" diameter base is current limited. Relay contact place a direct short
2 Wi re Auxil iary Relay Alarm Curr ent ID circuit across the loop when the detector is actuated.
Bases
HSC-224R 43mA (58mA @ 30.0V MAX) HB-73 Model HSC-4R is also approved for use with previous HOCHIKI
HSC-220R 88mA (98mA @ 26.5V MAX) HB-72 Conventional Models SIH-24F, SLK-24F, SLK-24FH and the DFE 135/
HSC-221R 49mA (62mA @ 30.0V MAX) HB-71 190.
4 Wire Base Alarm Curr ent ID
The HSC-4R12 is designed specifically for 12 volt 4 wire applications
HSC-4R 43mA (58mA @ 30.0V MAX) N/A
using HOCHIKI Conventional Models SLR-835, SLR-835H. The 6"
HSC-4R12 47mA (75mA @ 18.0V MAX) N/A
diameter base is current limited. Relay contact place a direct short
HSC- (X) L LATCHING LED BASE circuit across the loop when the detector is actuated.
Model HSC-4R12 is also approved for use with previous HOCHIKI
Conventional Model SLK-835.
The HSC-L Base Series is designed specifically for use with the
HOCHIKI Fixed Temperature Heat Detectors Models
DFE-135/ 190.
2 Wir e Latchi ng Alarm Curr ent ID
The HSC-L Series is a 6" base featuring a current limiting
HSC-224L 35-42mA @ 24V (54mA MAX) HB-62 resistor, latching annunciator output and a latching circuit so the
HSC-220L 67-80mA @ 24V HB-64
alarm LED will remain lit until the control panel has been reset.
(88.5mA @ 26. 5V DC MAX )
HSC-221L 37-45mA @ 24V (57mA MAX) HB-63
We try to keep our product information up-to-date and accurate. However, we cannot cover all specifications or
anticipate all requirements. For additional information contact your local distributor or Hochiki America Corporation.
UL LISTED
CONTROL LISTED
PANEL END OF LINE
DEVICE
UL LISTED LISTED
CONTROL END OF LINE
PANEL
DEVICE
GRY
BLU PIGTAIL AUXILLIARY
GRN CONTACTS
HSC- (X) R SERIES YEL
ORN TWO FORM "C"
PUR
LISTED
END OF LINE
RELAY
HA-EOLR-12 OR HA-EOLR-24
UL LISTED
POWER
SUPPLY
12VDC OR 24VDC
H1
H2 H1,H2 - TERMINAL
YEL PIGTAIL AUXILLIARY CONTACTS
ORN
PUR ONE FORM "C"
HSC-4R OR HSC-4R12
Relay Contact Ratings: 2A @ 30VDC
1A @ 120VAC
HSC- (X) L LATCHING LED BASE
2-WIRE OPERATION
COMPATIBLE
UL LISTED
CONTROL LISTED
PANEL 6 END OF LINE
DEVICE
PANEL
POWER Pig Tail Lead
SUPPLY HSC-(X) L SERIES NS6 SERIES
NEGATIVE
We try to keep our product information up-to-date and accurate. However, we cannot cover all specifications or anticipate all
requirements. For additional information contact your local distributor or Hochiki America Corporation.
Hochiki America Corporation Conventional Detector Bases Specifications subject to change without notice.
TSE-A100 SELF-CONTAINED SMOKE GENERATOR
APPLICATION
The Hochiki America TSE-A100 is one of the most
advanced units of its kind and is the result of extensive
research and development aimed at making the job of
testing detectors a simple and efficient operation .
OPERATION
Preparation
1. Remove the TSE-A100 from its carrying case.
2. Unscrew the combustion chamber from the
bottom of the TSE-A100.
3. Unscrew the punk stick holder retainer from
the combustion chamber.
4. Insert a punk stick into the punk stick holder in
the combustion chamber.
5. Light the punk stick with a flame.
STANDARD FEATURES 6. Reassemble the combustion chamber.
• Tests all types of smoke detectors. 7. Screw the combustion chamber back into the
• Completely self contained and portable. bottom of the TSE-A100
• Extends from 5.25 feet to 14.1 feet. 8. Extend the telescopic pole of the TSE-A100 to
• Internal Smoke Source. a length which enables you to reach the
• Non-Toxic Smoke Source. detector you wish to test.
• Unit includes shoulder sling carrying case.
• Optional adapter for high velocity conditions. Testing a Detector
Once you have prepared the TSE-A100, follow the steps
• Exhaust function to clear detector.
in this section to test smoke detectors.
• Built-in filter to prevent tar residue from adhering to
the surface of the detector. NOTE: Allow 30 to 60 seconds after igniting punk stick
for sufficient smoke generation.
SPECIFICATIONS
Continued on back
Rated Voltage 3 VDC
Battery 2 - "D" Batteries
PRODUCT PARTS
Combustion Material Punk Stick
(7 mm diameter, 150 mm long) • TSE-A100 Self-Contained Smoke Generator
Weight 5 Lbs. • Punk Stick (Part No. TSE-P100)
Length 5.25 to 14.1 feet
Color Brown
Specifications subject to change without notice.
NOTE
Combustion Chamber
Punk Stick
Instruction Label
STANDARD FEATURES
NSRT-C/NSRT-H
NSTT-C/NSRT-H
SPECIFICATIONS
Detector Tester/Removal Tool
Dimensions
NSRT-H: 4.0" D x 2.0" H
NSTT-H: 4.0" D x 1.5" H
Material Plastic Black Delrin
Color Black - provides visible contrast
Alignment
NSRT-H: One side for arrow labels for
easy visibility, one side for
removal from base.
NSTT-H: One side for sensitivity testing.
NSTT-C
The SIJ-24 and SLR-24/-835 series detectors, manufactured with magnetically activated dual reed switches for sensitivity
testing, can be sensitivity tested with the NSTT-C. This meets the requirements of a UL listed calibrated test without
the use of combustion materials.
The NSTT-C is in compliance with the test requirements outlined in the NFPA 72 Inspection, Testing and Maintenance,
Chapter 10.
Hochiki America Corporation NSRT & NSTT Specifications subject to change without notice.
TRT-A100 SMOKE DETECTOR TESTER/REMOVAL TOOL
APPLICATION
The HOCHIKI America TRT-A100 Smoke Detector Tester/
Removal Tool enables the user to access, test, remove
and reinstall the SIH and SLK series smoke detectors.
The detectors, manufactured with a magnetically
activated dual reed switch for sensitivity testing, can be
sensitivity tested. This meets the requirements of a UL
listed calibrated test without the use of combustion
materials.
3. If the detector does alarm when the removal/test tool is placed in this position, the detector is not within specified
sensitivity limits and may require service.
4. Rotate the TRT-A100 one-half circle (180°). Align white arrow shown on tester tool with tamper resistant set
screw.
5. Wait six to eight seconds. Detector SHOULD alarm and the indicator LED should remain lit.
6. If detector does not alarm when the TRT-A100 is positioned correctly, may not within specified sensitivity limits
and may require service. See Technical Bulletin HA-88 (November '96) for more information.
Removal Procedure
This section explains how to use the HOCHIKI America TRT-A100 Tester/Removal Tool to remove smoke detectors
from their bases.
1. Flip the TRT-A100 so the five small arrows located beneath the white orange arrows are point upward.
2. Fit the TRT-A100 to the detector and lock into place.
3. To remove a detector, rotate the TRT-A100 to the left (counterclockwise).
4. To install a detector, rotate the TRT-A100 to the right (clockwise).
APPLICATION
ADDRESS SETTING:
SPECIFICATIONS
Rated Voltage: 9 VDC
Battery: 9 VDC
Weight: 0.34 lbs
PRODUCT PARTS
Length: 6 1/4"
• 9 Volt Battery
Color: White
• Remote Programming Cables
Continued on back
Programming Buttons
Display
PROGRAMMING BUTTONS:
LEFT GRAY BUTTON Power on. Automatically reads the addresss of a sensor.
Subsequent operations will advance the device address by ten.
RIGHT GRAY BUTTON Power off. Advances the device address by one.
RED BUTTON Stores the displayed address to the device and is used to read sensor analog
levels.
To Remote
Programming Jack
Values out of these ranges indicate that the sensor chamber has become contaminated. Refer to technical
bulletin “HA-96” for proper servicing instructions or return sensor to factory for servicing.
DISPLAY MESSAGES:
bAt- On upon power up (battery check). Also on when battery is low. Low battery good for up to 3,000
address setting operation.
E0 - Attempting to set an address beyond 127.
E1 - Attempting to program an address with no device connected.
E2 - Can not find device after power up.
E3 - Invalid sensor response.
E4 - Can not find the device program.
E5 - Device read error.
E6 - Fail during Analog value reading
Hochiki America Corporation • TCH-B100 Hand-Held Programmer Specifications subject to change without notice.
FN-300-ULX, FN-400-ULX, FN-600-ULX, FN-1024-ULX
SPECIFICATIONS
FN-300-ULX:
• 24VDC or 12VDC rated @ 2.5 amps max
• Input 115VAC / 60Hz, 1.45 amps
• 12VDC or 24VDC selectable output
• Maximum charge current 0.7 amps
• Enclosure size of 13"H x 13.5"W x 3.25"D
FN-400-ULX:
• 24VDC or 12VDC rated @ 3 amps max
• Input 115VAC / 60Hz, 1.45 amps
• 12VDC or 24VDC selectable output
• Maximum charge current 0.7 amps
• Enclosure size of 13"H x 13.5"W x 3.25"D
FN-600-ULX:
• 24VDC or 12VDC rated @ 6 amps max
• Input 115VAC / 60Hz, 1.9 amps
• 12VDC or 24VDC selectable output
• Maximum charge current 0.7 amps
• Enclosure size of 13"H x 13.5"W x 3.25"D
DESCRIPTION FN-1024-ULX:
• 24VDC or 12VDC rated @ 10 amps max
The FN-300-ULX, FN-400-ULX, FN-600-ULX, and FN-
• Input 115VAC / 60Hz, 4.4 amps
1024-ULX are extremely cost effective voltage regu-
• 24VDC output
lated remote Power Extenders. These power supply/
• Maximum charge current 3.6 amps
charger s convert a 115VAC / 60Hz input, to a 12VDC
• Enclosure size of 15.5"H x 12"W x 4.5"D
or 24VDC regulated output. The ULX series Power
Extenders are designed to provide auxiliary power to
support system accessories. STANDARD FEATURES
• Input fuse rated @ 3.5 amps/250V
• Filtered and electronically regulated output
• Short circuit and thermal overload protection
• AC fail supervision (form "C" contacts)
• Low battery supervision (form "C" contacts)
PRODUCT LISTINGS • Battery presence supervision (form "C" contacts)
• Built-in charger for sealed lead acid or gel type
batteries
California • Automatic switch over to stand-by battery when AC
3022852 State Fire
fails
MEA
Marshal
• Zero voltage drop when switched over to battery
NYC Department backup
S8680 of Building 7315-0410:167
168-92-E Vol. 12 7315-0410:168
• AC input and DC output LED indicators
• Accommodates up to two (2) 12VDC/7AH batteries
• Power supply, enclosure, cam lock and battery leads
FN-842-ULADA:
• 24VDC OR 12VDC rated @ 8 amps max
• Four (4) Class A or Four (4) Class B outputs
• Enclosure size of 18"H x 14.5"W x 4.625"D
FN-1042-ULADA:
• 24VDC OR 12VDC rated @ 10 amps max
• Four (4) Class A or Four (4) Class B outputs
• Enclosure size of 18"H x 14.5"W x 4.625"D
STANDARD FEATURES
• Two (2) Class A or (2) Class B FACP inputs
• Two (2) NC dry contact trigger inputs
• Four (4) Class A or Four (4) Class B indicating
circuits
• Two (2) Class B outputs may be paralleled for
DESCRIPTION more power on an indicating circuit
The FN-642-ULADA, FN-842-ULADA, and FN-1042- • One (1) Aux. Power Output @ 1 amp supply
ULADA are extremely cost effective voltage regulated current (with or without battery back up)
remote NAC Power Extenders. They may be con- • Signal Circuit Trouble Memory - Facilitates quickly
nected to any 12 or 24VDC Fire Alarm Control Panel locating intermittent system trouble and eliminates
(FACP). Primary applications include Notification costly and unneccessary service calls. LED's
Appliance Circuit (NAC) expansion (supports ADA indicate a prior fault (short, open, ground) has
requirements) and will provide auxiliary power to occured on one or more signaling circuit outputs.
support system accessories. • 2 wire Horn/Strobe Sync mode allows audible
notification appliances (Horns) to besilenced while
visual notification appliances (Strobes) continue to
operate
• Horn/Strobe sync protocols include: Gentex,
System Sensor, Faraday, Wheelock and Amseco.
PRODUCT LISTINGS
• Temporal Code 3 Mode
• Steady Mode
California • Input to Output Follower Mode (maintains
3022852 State Fire synchronization of notification appliance circuits)
MEA •
Marshal March Time
NYC Department
• Compatible with 24VDC or 12VDC fire panels
S5694 of Building 7315-0410:171 • Input 115VAC
220-95-E Vol. 18 • AC fail, battery presence & low battery monitoring
• Accommodates up to two (2) 12VDC/12AH batteries
• Power supply, logic board, red enclosure, cam lock,
transformer & battery leads
Specifications subject to change without notice
SPECIFICATIONS
PE-6SN:
• 24VDC rated @ 6 amps max
• Two (2) Class A or Four (4) Class B outputs
• Enclosure size of 16 3/4"H x 16 1/8"W x 3 1/2"D
PE-10SN:
• 24VDC rated @ 10 amps max
• Three (3) Class A or Six (6) Class B outputs
• Enclosure size of 16 3/4"H x 16 1/8"W x 3 1/2"D
STANDARD FEATURES
• 120/240 VAC 50/60 Hz Input
• PE-6SN offers 6 amps, PE-10SN offers 10 amps
• Two (2) Trouble Relays
DESCRIPTION • Two (2) Class A or B trigger circuit
• One (1) Programmable AUX power rated @ 3 amps
The PE-6SN and PE-10SN are voltage regulated • Quadrasync provides panel wide synchronization of
remote NAC Power Extenders. They may be con- the same or multiple brands
nected to any 24VDC Fire Alarm Control Panel • Pass Thru mode allows the Outputs to match the
(FACP). Primary applications include Notification Input Signal
Appliance Circuit (NAC) expansion (supports ADA • Signal Circuit Trouble Memory - Facilitates quickly
requirements) and will provide auxiliary power to locating intermittent system trouble and eliminates
support system accessories. The Power Extender costly and unneccessary service calls. LED's
offers an industry leading Quadrasync function that indicate a prior fault (short, open, ground) has
allows for multiple strobe circuits of different brands to occured on one or more signaling circuit outputs.
be synchronized to flash at the same time. The panel • Horn/Strobe sync protocols include: Gentex,
can have four different brands each connected to its System Sensor, Wheelock and Amseco/Potter.
own circuit and all of the strobes flash together in • Temporal Code 3 Mode
addition to the horns. • Configurable output circuits (DIP switch sets options
for each circuit)
• 15 mA at 8-33 VDC input trigger
• Reference EOL allows 2K-27K EOL value to be used
• AC fail, battery presence & low battery monitoring
PRODUCT LISTINGS • Supports 7 - 55AH batteries
• Accommodates up to two (2) 12VDC/18AH batteries
California • Power supply, logic board, red enclosure, cam lock
State Fire (CAT30), transformer & battery leads
Marshal
S5694 7315-0410:197
SPECIFICATIONS
FNV-MP
Primary Power 120VAC @ 60Hz
220VAC @ 60Hz
Input Current 0.28 Amp @ 120VAC
Input Current 0.28 Amp (Typical Load 0.4
(Battery) Amp Maximum Load)
Batt. Charging 800 mA
Current
Batt. Size Minimum: 24VDC @ 7AH
Maximum: 24VDC @ 18AH
Batt. Type Two 12VDC Gel Cell (in series)
Dimensions 14.5"W x 27"H x 4"D
Color Red / Charcoal Gray
STANDARD FEATURES FNV-DP
Primary Power 120VAC @ 60Hz
• UL 864 9th Edition Listed 220VAC @ 60Hz
• True Multiplex 6 Channel Distributed Audio Input Current FNV-25 / 25E: 0.8 Amps @ 120VAC
• Integrated Fire Phone, Area of Rescue and Fan FNV-50 / 50E: 0.5 Amps @ 120VAC
& Damper Control capability FNV-100 / 100E: 1 Amps @ 120VAC
• Modular System - components added as needed Output Power FNV-25 / 25E: 25 Watts
• Integrated 2 Channel Digital Message Repeater FNV-50 / 50E: 50 Watts
• Live Microphone Page to any zone FNV-100 / 100E: 100 Watts
• Fast RS-485 Communication Protocol Freq. Response FNV-25 / 25E: 800 ~ 2800 Hz
• Fully Supervised FNV-50 / 50E: 400 ~ 4000 Hz
• Easy Installation and Operation FNV-100 / 100E: 400 ~ 4000 Hz
• Natural Voice Sound Recordings Output Voltage 25 / 70 Vrms Selectable
• Built-in Alarm and Alert Signals Input Current FNV-25 / 25E: 0.18 Amps / 1.1 Amps
• Up to 4 Minute Message Capacity (Battery) FNV-50 / 50E: 0.15 Amps / 1 Amps
• Works with 12VDC or 24VDC Fire Alarm Panels FNV-100 / 100E: 0.16 Amps / 1.1 Amps
• UL listed to be integrated with FireNET 2127/4127 Batt. Charging 800 mA
• 3 Minute Message Restart on Microphone Key Batt. Size Maximum: 24VDC @ 7AH
• Up to 256 Distributed Panels Maximum: 24VDC @ 18AH
Maximum: 24VDC @ 24AH
(FNV-DP100)
Batt. Type Two 12VDC Gel Cell (in series)
PRODUCT LISTINGS Dimensions 14.5"W x 27"H x 4"D
Color Red / Charcoal Gray
California
State Fire
Marshal
6911-0410:175
S5694
The Hochiki FNV includes all necessary features to provide an effective voice evacuation system. The Hochiki FNV
can be custom configured to satisfy the needs of any high rise application.
Fire department authorities can easily take command of evacuation or relocation procedures and emergencies.
Building management and fire brigades can monitor and control emergency response even before the
professionals arrive.
The FNV system includes capacity for 6 channels of simultaneous audio. This provides for evacuation, stay-in-
place, or other public address announcements and automatic messages.
Fire Fighter Phones or Warden Stations may be included as required. Area-of-Rescue stations can reassure
handicapped occupants that help is on the way. Smoke control, stair pressurization, and HVAC shutdown can be
completely automatic,unless controlled manually by management or fire authorities.
WIRING DIAGRAM
D is trib u te d P a n e l
Voice Evacuation
S p e a k e r Circuits
F
I
R
E
F
I
R
E
TB1
T B2 TB 1
T B2
T B3 T B3
Fire
FNV-25 FN V-25
FNV-50 FN V-50
FN V-100 FN V-100
Phone
L o c a l A u d io Amplifiers
F i re Phone
Circuit
N e tC o m m L o o p : U ns h ie ld e d T w is te d P a ir, S in g le pair
1 8 / 2 o r la rg e r, U n s h ie ld e d tw is t e d pair (U T P )
F P L , F P L R , F P L P run in conduit
D is trib u te d P a n el
Voice Evacuation
S p e a k e r Circuits
F
I
R
E
M a s te r P a n e l
H e a d E n d C o n tr o l
F
I
R
E
TB1 TB 1
T B2 T B2
PAG ING
CONTROL
FNV-25 FNV-25
FNV-50
FNV-10 0
FNV-50
Phone
FNV-10 0
L o c a l A u d io Amplifiers
F i re Phone
Circuit
F IR E P HO NE CONTROL
Hochiki America Corporation FNV-MP & FNV-DP Specifications subject to change without notice.
Description:
Fire Phone accessories give the FNV system two
VoiceNet
way communication capability. Fire Phone Equipment
Fire Phone jacks are mounted on a single gang plate.
FNV-FJ
Ordering Information:
Model Number Description
LISTED
7051 Village Drive, Suite 100 Buena Park, CA 90621-2268 714.522.2246 www.hochiki.com
10K 1/2W
EOLR
10K 1/2W
EOLR
10K 1/2W
EOLR
EOLR
#22 AWG min.
Fire Phone Fire Phone
Handset Handset
Jack Jack
10K 1/2W
EOLR
(not shown)
1 2 3 4 1 2 3 4 1 2 3 4 1 2
TB1 TB2 TB3 TB
1 2 3 4
TB5
1 2 3 4
TB6
FPO Fire
1 2 3 4
Phone TB7
Loops
(Supervised)
MBR
/
10 Pin Ribbon Cable FPI
Cards plug into slots
available on MBR
First FPI allows 4 Fire Phone
Circuits off of MBR. Adding 2nd
FPI and an FPO allows 4
additional Fire Phone Circuits
(16 circuits max. in any FNV-DP)
STANDARD FEATURES
The EVAX 25 has its own power supply and battery 24 VDC Battery Power;
charger. Panel must be wired with 120 VAC and Standby 0.18A
standby batteries connected.
Alarm 1.00A
A digital message repeater (DMR) is built into the Output 25 Watts @ 25/70 VRMS
EVAX 25. The selection of alarm tone and automatic tone and voice
message repeats, as well as the 6 Hour delay of the Backbox Dimensions 14.5"W x 18"H x 4"D
AC power failure reporting feature are all field
configurable. Color Red/Charcoal Grey
Continued on back.
Specifications subject to change without notice
The voice evacuation system shall be EVAX Systems Series EVAX 25 or approved equal.
The voice evacuation system shall provide 25 watts signal power and 25 watts voice power, and shall be UL listed.
The voice evacuation system shall be micro-processor based, and shall contain an integral microphone, 25-Watt
audio amplifier, tone generator, digital message repeater, 120VAC power supply and battery charger.
The voice evacuation message/signal shall be broadcast until the Fire Alarm Control Panel (FACP) is reset, or until
fire emergency personnel interrupt the broadcast with a manual page. On reset system shall automatically return
to standby (normal operating) condition.
A secondary message shall be provided which can be triggered by the closure of a contact from either the FACP
or from any normally open contact device.
Remote paging microphone (s) will be supported by the system through a supervised circuit. Remote microphone
(s) can be mounted up to 5000 feet away from the voice evacuation panel.
WIRING DIAGRAMS
Power
Transformer*
*Power Transformer is
built into the EVAX 50
TB1 1 2 3 4 5 6 7 8
TB3 TB2
1 11
2 10
3 9
4 8
5 7
6 6
7 Trouble 5
4
8
3
Normal 2
1
Alarm
System Status LEDs
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
12 V - 12 V -
Battery Battery
+ +
ORDERING INFORMATION
The voice evacuation system shall be EVAX Systems Series EVAX 50 or approved equal.
The voice evacuation system shall provide 50 watts signal power and 50 watts voice power, and shall be UL listed.
The voice evacuation system shall be micro-processor based, and shall contain an integral microphone, 50 Watt
audio amplifier, tone generator, digital message repeater, 120VAC power supply and battery charger.
The voice evacuation message/signal shall be broadcast until the Fire Alarm Control Panel (FACP) is reset, or until
fire emergency personnel interrupt the broadcast with a manual page. On reset system shall automatically return
to standby (normal operating) condition.
A secondary message shall be provided which can be triggered by the closure of a contact from either the FACP
or from any normally open contact device.
Remote paging microphone (s) will be supported by the system through a supervised circuit. Remote microphone
(s) can be mounted up to 5000 feet away from the voice evacuation panel.
WIRING DIAGRAMS
Power
Transformer*
*Power Transformer is
built into the EVAX 50
TB1 1 2 3 4 5 6 7 8
TB3 TB2
1 11
2 10
3 9
4 8
5 7
6 6
7 Trouble 5
4
8
3
Normal 2
1
Alarm
System Status LEDs
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
12 V - 12 V -
Battery Battery
+ +
ORDERING INFORMATION
WIRING DIAGRAMS
Power
Transformer*
*Power Transformer is
built into the EVAX 50
TB1 1 2 3 4 5 6 7 8
TB3 TB2
1 11
2 10
3 9
4 8
5 7
6 6
7 Trouble 5
4
8
3
Normal 2
1
Alarm
System Status LEDs
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
12 V - 12 V -
Battery Battery
+ +
ORDERING INFORMATION
Model Number Description
EVAX 100 100W Voice Evacuation System, with power supply/battery charger, paging
microhpne and digital message repeater
EVAX 100/4Z 100W Voice Evacuation System, with 4 speaker zones
EVAX 100/8Z 100W Voice Evacuation System, with 8 speaker zones
EVAX 100/12Z 100W Voice Evacuation System, with 12 speaker zones, in a large cabinet
14.5"w x 27h" x 4"d
EVAX 100/16Z 100W Voice Evacuation System, with 16 speaker zones, in a large cabinet
14.5"w x 27h" x 4"d
Hochiki America Corporation EVAX-100 Specifications subject to change without notice.
EVAX - 150 & 200 Voice Evacuation System
STANDARD FEATURES
• Clean dead-front construction
• Digitally recorded automatic voice evacuation
(up to 4 minutes of message capacity)
• 50/100 Watt high efficiency digital amplifier
• 25 or 70 VRMS field selectable
• 120 VAC power supply and battery charger
• Live microphone override of message and tone
• Analog addressable compatible
• High reliability, no maintenance, fully supervised
• Easy installation and operation
• Natural voice sound recordings
• Built-in alarm and alert signals
• Up to 4 minute message capacity
• Works with 12VDC or 24VDC fire alarm panels
DESCRIPTION • Works with analog/addressable and
microprocessor based fire alarm panels
The EVAX 150/200 operates with any Fire Alarm • 3 minute message restart on microphone key
Control
.
Panel (FACP), and provides 150/200 Watts of • 24 hour backup with two 12V 7 AHr batteries
speaker power. • Made in the USA
WIRING DIAGRAMS
Control EOLR
Panel NAC
Class "A" Speaker Circuit if required
F F
Voice Evacuation Speaker Circuit I I
R R
E E
Supervise - Power Limited
120 EOLR
VAC Class "A" Speaker Circuit if required
TB1 1 2 3 4 5 6 7 8 TB1 1 2 3 4 5 6 7 8
Normal 2 Normal 2
1 1
Alarm Alarm
System Status LEDs System Status LEDs
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
12 V - 12 V -
Battery Battery
+ +
ORDERING INFORMATION
Model Number Description
EVAX 150 150W Voice Evacuation System, with power supply/battery charger, paging
microhpne and digital message repeater
EVAX 200 200W Voice Evacuation System, with power supply/battery charger, paging
microhpne and digital message repeater
Hochiki America Corporation EVAX-150 & 200 Specifications subject to change without notice.
HE Series Selectable Candela Evacuation Signals
STANDARD FEATURES
• Nominal voltage 12VDC and 24VDC
• 24VDC units have field selectable candela options
of 15, 30, 60, 75, and 110 candela
• 12VDC units have field selectable candela options of
15, 30, 60, and 75 candela
• Unit Dimensions: 5" high x 4.5" wide x 2.5" deep
• Synchronize strobe and/or horn with Hochiki Series
Control Module (12VDC product must use the
HAVSM Module)
• Prewire entire system, then install signals
• Lower installation and operating costs
• Input terminals supports 12 to 18 gauge wire
• Switch selection for high or low dBA
HEC/HES/HEH • Switch for chime, whoop, mechanical and 2400Hz
tone
• Switch for continuous or temporal 3 (not available on
APPLICATIONS whoop tone)
The HE Series is a low profile strobe and horn/strobe • Surface mount with the HSB (Hochiki surface
combination that offers dependable audible and visual mount box)
alarms and the lowest current available. • Silence horn while strobes remain flashing
• Wide voltage range 8-17.5VDC (12VDC units) 16-
The HE Series 24VDC offers tamperproof field select-
33VDC or FWR (24VDC units)
able candela options of 15, 30, 60, 75, and 110
• Faceplate available in red or off-white
candela.
The 12VDC models offers tamperproof field selectable
candela options of 15, 30, 60, and 75 candela. The
PRODUCT LISTINGS
HE Series horn offers a continuous or synchable California State
temporal three in 2400Hz and mechanical tone, a Fire Marshal
chime and whoop tone. All tones are easy for the
professional to change in the field by using switches.
• UL 464 & UL 1971 Listed - S8369
The HE Series has a minimal operation current and • CSFM Listed - 7135-0410:0187, 7135-0410:0188
has a minimum flash rate of 1Hz regardless of input
voltage. Product Compliance
The HE Series is shipped with the standard 4" metal • NFPA 72
mounting plate which incorporates the popular Slide • Americans with Disabilities Act (ADA)
feature that allows the installer to easily test for
supervision. The product also features a locking
mechanism which secures the product to the bracket
without any screws showing.
The HE Series appliances are UL 464 and UL 1971
listed for use with fire protective systems and are
warranted for three years from date of purchase.
STANDARD FEATURES
• Nominal Voltage 24 VDC
• Tamperproof Field Selectable candela options of 15,
30, 75, 95,115 & 150
• Unit Dimensions: 6" x 2.6"
• Synchronize HC Series by using Hochiki America
Series Control Module
• Input Terminals support 12 to 18 AWG
• Switch Selection for High or Low dBA
• Switch Selection for 2400Hz or Mechanical Tone
• Switch Selection for Continuous or Temporal 3
• Tamperproof Re-entrant Grill
HCS/HCC 24VDC SERIES
• Surface Mount with the HCSB (Hochiki Ceiling
Surface Mount Box)
APPLICATIONS • Silence Horn While Strobes Remain Flashing
• Wide Voltage Range 16-33 VDC or FWR
The HC Series is a ceiling mount strobe or horn/strobe • Faceplate Available in Red or Off-White
combination that offers dependable audible and visual
alarms and the lowest current available.
PRODUCT LISTINGS
The HC Series offers tamperproof field selectable
candela options of 15, 30, 75, 95, 115 and 150 California State
Fire Marshal
candela.
The HC Series horn offers a pattern or synchable
temporal 3 in 2400Hz or mechanical tone. These tones
• UL 464 & UL 1971 Listed - S8369 & S3597
are easy for the technician to change in the field by
• CSFM Listed - 7125-0410:0187, 7125-0410:0188
using switches.
The HC Series has a minimal operating current and a Product Compliance
minimum flash rate of 1Hz regardless of input voltage. • NFPA 72
The HC Series comes standard with the 4" mounting • Americans with Disabilities Act (ADA)
plate which incorporates the popular Super-Slide®
feature that allows the installer to easily test for
supervision.
The HC Series appliances are UL 464 and UL 1971
listed for use with fire protective systems.
Notes:
• The HC Series is not listed for outdoor use.
• Operating temperature: 32°to 120°F (0° to 49° C)
• For nominal and peak current across UL regulated voltage range for filtered DC
power and unfiltered (FWR [Full Wave Rectified]) power, see installation manual.
• Hochiki does not recommend using a coded or pulsing signaling circuit with any
of our strobe products (see technical bulletin number 014 for more information).
Model designations:
”P” = Plain (no lettering) “C” = Ceiling Mount, “R” = Red Faceplate/”W” = Off-White Faceplate
*Operating the horn in this mode at this voltage will result in not meeting the minimum UL reverberant sound level
required for public mode fire protection service. These settings are acceptable only for private mode fire alarm
use. Use the high dBA setting for public mode application.
Notes: The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the
sound output rating. While the horn is producing a tone in the temporal 3 mode its sound pressure is the same
as the continuous mode.
To obtain the horn/strobe current draw, add the strobe current draw and the horn current draw.
2
RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within
the listed voltage range (16-33VDC for 24VDC units). For strobes the UL max current is usually at the minimum
listed voltage (16VDC for 24VDC units). For audibles the max current is usually at the maximum listed voltage.
For unfiltered FWR ratings, see installation manual.
Hochiki America Corporation HC Series Selectable Ceiling Mount Strobe and Horn Strobe Specifications subject to change without notice.
HGOE-R / HGOE-W Outdoor Enclosure
SPECIFICATIONS
Models HGOE-R, HGOE-W
Dimension 4.75”W x 5.75”H x 4.18”D
Conduit Knockouts 0.75”
Colors Red or Off-White
STANDARD FEATURES
• Weatherproof seal
• Made of Clear Lexan® - providing maximum visibility
and reliability for effective visible signaling
• UV Stable Polycarbonate Lens
• Back-box or side mount with mounting tabs
HGOE-R/HGOE-W • Reinforcement Steel Hardware
• Textured plastic Finish
• Available in red or off-white
APPLICATIONS
The HGOE-R and HGOE-W are UL listed for outdoor
use with the HEH, HES and the WHE Series Strobe
and horn/strobe.
PRODUCT LISTINGS
California State
Fire Marshal
Product Compliance
• NFPA 72
• Americans with Disabilities Act (ADA)
Specifications subject to change without notice.
HCSB-R/HCSB-W HSB-R/HSB-W
HBLP-R/HBLP-W
Product Compliance
• NFPA 72
• Americans with Disabilities Act (ADA)
Specifications subject to change without notice.
STANDARD FEATURES
• Synchronize Horn and Strobe with the use of only
two wires
• Module is Rated for 3 Amps Continuous Current
and 5 Amps Surge or Inrush Current
• Synchronizes to 1Hz Flash Rate
• Operates 1 "Class A" circuit or 2 "Class B" circuits
at 3 Amps per Circuit
• Dual Synchronization Module Only when Using
"Class B" circuits
• A Green LED status indicator
• Option to Silence the Horn while Strobes continue
to Flash when using Temporal 3 Mode
• HAVSM Operates the HCS/HCC, HES3-24/HEC3-
HAVSM 24, HES3-12/HEC3-12, HEC/HES/HEH, HSSPK
Series and HX93 Series.
• HAVS module come with its own back box and
cover plate
APPLICATIONS • Dimensions of Module: 3.85"H x 3.82"W x 1.32"D
• Dimensions of Box: 5.57"H x 4.55"W x 2.39"D
The HAVSM control modules are designed to provide • Available in Fire Alarm Red or Off-White.
an easy way to synchronize multiple horns as well as
strobe light flashes using only two wires in instances
where a synchronized flash is required. HAVSM SYNC CONTROL MODULE
When the module is in temporal 3 mode, it has the Model Part
cabability to synchronize multiple horn signals and Number Number
the ability to silence the horn while allowing the HAVSM-R 0500-06340
strobes to continue to flash. In unison mode, the horn HAVSM-W 0500-06350
cannot be silenced while maintaining strobe operation.
Model Designations:
R = Red faceplate W = Off-white faceplate
Operating temperature - Indoor Use Only
Indoor: 32°to 120°F (0° to 49° C)
Product Compliance
• NFPA 72
Specifications subject to change without notice.
STANDARD FEATURES
PRODUCT LISTINGS
California State
Fire Marshal
Product Compliance
• NFPA 72
• Americans with Disabilities Act (ADA)
Specifications subject to change without notice.
Notes:
• The HSSPKCLP Series is not listed for outdoor use
• Operating temperature: 32° to 120° F (0° to 49° C)
Model designations:
”P” = Plain (no lettering), “R” = Red Faceplate, ”W” = Off-White Faceplate
1
RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within
the listed voltage range (16-33VDC for 24VDC units). For strobes the UL max current is usually at the minimum
listed voltage (16VDC for 24VDC units). For audibles the max current is usually at the maximum listed voltage.
For unfiltered FWR ratings, see installation manual.
Hochiki America Corporation HSSPKCLP Series Ceiling Mount Speaker/Strobe Specifications subject to change without notice.
HSSPKWLP Series Wall Mount Speaker/Strobe
STANDARD FEATURES
PRODUCT LISTINGS
California State
Fire Marshal
Product Compliance
• NFPA 72
• Americans with Disabilities Act (ADA)
Specifications subject to change without notice.
Notes:
• The HSSPKWLP Series is not listed for outdoor use
• Operating temperature: 32° to 120° F (0° to 49° C)
Model designations:
”P” = Plain (no lettering), “R” = Red Faceplate, ”W” = Off-White Faceplate
1
RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within
the listed voltage range (16-33VDC for 24VDC units). For strobes the UL max current is usually at the minimum
listed voltage (16VDC for 24VDC units). For audibles the max current is usually at the maximum listed voltage.
For unfiltered FWR ratings, see installation manual.
Hochiki America Corporation HSSPKWLP Series Wall Mount Speaker/Strobe Specifications subject to change without notice.
HX93 Series Mini-Horn
STANDARD FEATURES
• Nominal voltage 12VDC and 24VDC
• Jumper for Selectable Temporal 3 or Continuous
tone
• Horn Frequency of 3100Hz
• Input terminals supports 12 to 18 gauge wire
• Low Current Consumption
• Textured Finish High Impact Plastic Faceplate
• Available in Fire Alarm Red or Off-White.
STANDARD FEATURES
Product Compliance
• NFPA 72
• Americans with Disabilities Act (ADA)
NOTES:
• The HES Series is listed for outdoor use.
Indoor Operating temperature: 32°to 120°F (0° to 49° C)
Outdoor Operating Temperature: -31°to 150°F (-35° to 66° C)
*Operating the horn in this mode at this voltage will result in not meeting the minimum UL reverberant sound level
required for public mode fire protection service. These settings are acceptable only for private mode fire alarm use.
Use the high dBA setting for public mode application (not applicable when using the chime tone. The chime tone is always
private mode).
Notes: The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound
output rating. While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous
mode.
1
RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the
listed voltage range (16-33VDC for 24VDC units). For strobes the UL max current is usually at the minimum listed voltage
(16VDC for 24VDC units). For audibles the max current is usually at the maximum listed voltage. For unfiltered FWR
ratings, see installation manual.
Hochiki America Corporation HEP/HEPS Series Specifications subject to change without notice.
B6-24 / B10-24 / BB-WP - FIRE ALARM BELL
SPECIFICATIONS
Model B6-24, B10-24
Operating Voltage 24VDC
Alarm Current 100mA
dB at 10ft. 96dB
Operating Temperature 32°F to 120° F
(Indoor Application) (0° C to 48° C)
Operating Temperature -32°F to 150° F
(Outdoor Application) (-35° C to 65° C)
Color / Material Red / Metal
STANDARD FEATURES
B6-24/B10-24/BB-WP • UL Listed
• Available in 6" or 10" version
• High dbA output
WIRING DIAGRAM • Mounts to a standard 4" square electrical box
• ANSI/UL Listed for outdoor use when used with the
BB-WP weatherproof back box
• 18 AWG wire leads
• Meets ANSI/UL 464 requirements
• Red metal finish
APPLICATIONS
The B6-24 and B10-24 provide durable and depend-
able operation required for life safety alarm systems.
MOUNTING Alarm bells are low current, high decibel notification
appliances for use in fire or other signaling applica-
tions. The alarm bell is powered by 24VDC.
Alarm bells are available in 6" or 10" version and listed
for indoor and outdoor applications. Alarm bells must
be used with the BB-WP weatherproof box for outdoor
use.
PRODUCT LISTINGS
California State
Fire Marshal
• UL 464 - S1529
• CSFM Listed - 7135-0410:0209
Product Compliance
• NFPA 72
Specifications subject to change without notice.
STANDARD FEATURES
APPLICATIONS DESCRIPTION
• Data Centers (Server Room) FNX Series products are a SBK aerosol forming solid
• Computer Rooms compound (containing no pyrotechnic substances)
• Central Stations (Call centers) that is used to extinguish Class A, B, C fires. The FNX
• Mechanical / Electrical Control Rooms Series products are electrically activated. The con-
• Shipping Warehouse densed aerosol extinguishing mechanism works by
• Plant Rooms removing the active chemical particles involved in the
• Engine Rooms flame chain reaction.
• Vehicle Storage Rooms (Hangar Bay)
TRANSPORTATION CLASSIFICATION
• Class 9
• UN Identification: 3335 (Air) & 3077 (Ocean)
• Packaging group: PGIII
Canister Type
Model FNX-100S FNX-200S FNX-500S
Mass of SBK 100g 200g 500g
Product weight 1370g ±5% 1840g ±5% 3340g
Supply Voltage 6 ~ 36 VDC 6 ~ 36 VDC 6 ~ 36 VDC
Initiation Current 0.8 A 0.8 A 0.8 A
Heating Element Resistance 1.6 – 3.6 Ohms 1.6 – 3.6 Ohms 1.6 – 3.6 Ohms
Supervision Current 5mA 5 mA 5 mA
Ignition Time 4 seconds 4 seconds 4 seconds
Discharge Time 5 – 10 seconds 5 – 10 seconds 5 – 10 seconds
Min. Discharge Clearance 1.3ft (400mm) 0.9ft (300mm) 1.6ft (500mm)
Max. Mounting Height 3.2ft (1m) 6.5ft (2m) 6.5ft (2m)
Storage -58°F (-50°C) - 122°F (50°C) -58°F (-50°C) - 122°F (50°C) -58°F (-50°C) - 122°F (50°C)
Temperature
Self-Activation Temperature 572°F (300°C) 572°F (300°C) 572°F (300°C)
Dimensions 6.1”H (155mm) x 3.4”D (84mm) 7.2”H (185mm) x 3.4”D (84mm) 11.6”H (295mm) x 3.4”D
(84mm)
B ox T ype
Model FN X-1200 FN X-2000 FN X-3000 FN X-5700
Mass of SBK 1200g 2000g 3000g 5700g
Product weight 10900g ±5% 15500g ±5% 16300g ±5% 26400g ±5%
Supply Voltage 6 ~ 36 VD C 6 ~ 36 VD C 6 ~ 36 VD C 6 ~ 36 VD C
Initiation C urrent 0.8 A 0.8 A 0.8 A 0.8 A
H eating Elem ent 1.6 – 3.6 O hm s 1.6 – 3.6 O hm s 1.6 – 3.6 O hm s 1.6 – 3.6 O hm s
R esistance
Supervision C urrent 5 mA 5 mA 5 mA 5 mA
Ignition Tim e 4 seconds 4 seconds 4 seconds 4 seconds
D ischarge Tim e 15 – 20 seconds 15 – 20 seconds 15 – 20 seconds 15 – 20 seconds
Min. D ischarge 5.4ft (1650m m ) 4.9ft (1500m m ) 6.5ft (2000m m ) 6.5ft (2000m m )
C learance
(H um an)
Ma x. Mounting H eight 11.4ft (3.5m ) 11.4ft (3.5m ) 11.4ft (3.5m ) 16.4ft (5m )
Storage -58°F (-50°C ) - 122°F -58°F (-50°C ) - 122°F -58°F (-50°C ) - 122°F -58°F (-50°C ) - 122°F
Tem perature (50°C ) (50°C ) (50°C ) (50°C )
Self-Activation 572°F (300°C ) 572°F (300°C ) 572°F (300°C ) 572°F (300°C )
Tem perature
D im ensions 6.5”H (167m m ) x 7.2”H (185m m ) x 7.2”H (185m m ) x 11.8”H (300m m ) x
11.8”L (300m m ) x 11.8”L (300m m ) x 11.8”L (300m m ) x 11.8”L (300m m ) x
8.5”W (216m m ) 11.8”W (300m m ) 11.8”W (300m m ) 11.8”W (300m m )
Hochiki America Corporation FireNET Xtinguish Specifications subject to change without notice.
HCVR-3
CONVENTIONAL RELEASING FACP
STANDARD FEATURES
PRODUCT LISTINGS
California
State Fire
Marshal 3046396
S6468 7165-0410:0206
Continued on back.
Specifications subject to change without notice.
SPECIFICATIONS
Supply Voltage 20 to 30 VDC
Dimensions 15.1”(W) x 12.2(H) x 3.54”(D)
Available Models HCVR-AB (Board Only),
HCVR-ABE-R, HVCR-ABE-C
Color Red or Charcoal
Wiring Length 4000 ft. (RS485)
Standby Current 16 mA
Alarm Current 175 mA
Wiring Gauge 14 to 22 AWG
Relay Contact 30VDC @ 1 Amp (Voltage free
DESCRIPTION change over contact)
Operating Humidity 95% RH (Non-Condensing)
Operating Temperature 23°F to 122°F
The HCVR-AB is a Ancillary Board that provides volt
free normally open contacts allowing control
remotely from the HCVR-3 FACP.
PRODUCT LISTINGS
California
State Fire
Marshal 3046396
S6468 7300-0410:0207
SPECIFICATIONS
Supply Voltage 21 to 28 VDC
Dimensions 7.3” (W) x 5.2 (H) x 1.9” (D)
Weight 9 lbs.
Color Red or Charcoal
Surface Mount Models HCVR-SDU-6S-R, HCVR-
SDU-6S-C, HCVR-SDU-6SM-
R, HCVR-SDU-6SM-C
Flush Mount Models HCVR-SDU-6F-R, HCVR-
SDU-6F-C, HCVR-SDU-6FM-
R, HCVR-SDU-6FM-C
Wiring Length 4000 ft. (RS485)
Standby Current 50 mA
DESCRIPTION Alarm Current 94 mA
Wiring Gauge 18 to 22 AWG
The HCVR-SDU is a status indicator that provides Operating Humidity 90% RH (Non-Condensing)
detailed status information for the HCVR-3 Releasing Operating Temperature 23°F (-5°C) to 122°F (50° C)
FACP.
PRODUCT LISTINGS
California
State Fire
Marshal 3046396
S6468 7300-0410:0207
SPECIFICATIONS
Models HCVR-AS-R (Red)
HCVR-AS-C (Charcoal)
Switch Rating 1A @ 30VDC
Dimension 3.81" W x 3.81" H x 2.32" D
STANDARD FEATURES
• UL and FM approved
• Capable of aborting releasing operation
• Available in Red and Charcoal
• Includes a backbox for surface mount
HCVR-AS
DESCRIPTION
PRODUCT LISTINGS
California
State Fire
Marshal 3046396
S6468 7300-0410:0207
SPECIFICATIONS
Models HCVR-SQA
Supply Voltage 24VDC
Average Current 1mA
Consumption
Maximum Output 1A @ 24VDC
Current
Material Mild Steel
Dimension 3.58" W x 3.58" H x 1.61" D
COMPATIBILITY LIST
CANISTER TYPE GENERATOR TYPE
Hochiki America:
FNX-100S FNX-1000
HCVR-SQA FNX-200S FNX-2000
FNX-500S FNX-3000
FNX-5700
FirePro:
STANDARD FEATURES
FP-100S FP-1000
FP-200S FP-2000
• UL and FM approved FP-500S FP-3000
• Capable of releasing two Aerosol generators or FP-5700
Canisters
• Includes a backbox for surface mount
• LED Indicates for output supervision trouble
DESCRIPTION
PRODUCT LISTINGS
California
State Fire
Marshal 3046396
S6468 7300-0410:0207
SPECIFICATIONS
Model HPS-DAK-SR
Contact (1) Form A
Contact Rating 10A @ 120 VAC
Operating Temperature -30°F (-35 °C) ~ 150°F (66°C)
STANDARD FEATURES
• Metal Construction
• Enclosed switch with glass rod (included)
• UL, CSFM Listed
• Made in USA
DESCRIPTION
PRODUCT LISTINGS
California
State Fire
Marshal
7150-0410:162
S6512
SPECIFICATIONS
Models HCVR-DS-R (Red)
HCVR-DS-C (Charcoal)
Switch Rating 1A @ 30VDC
Dimension 3.81" W x 3.81" H x 2.32" D
STANDARD FEATURES
• UL and FM approved
• Physical switch provides NFPA-compliant
disconnect solution for releasing service
• Includes a backbox for surface mount
HCVR-AS
DESCRIPTION
PRODUCT LISTINGS
California
State Fire
Marshal 3046396
S5694 7300-0410:0207
SPECIFICATIONS
Model SOM-R-DS
Switch Rating 4A @ 28VDC
Material Metallic
Dimension 2.31” W x 4.19” H x 1.5” D
Operating 32°F (0°C) ~ 120°F (49°C)
Temperature
Relative Humidity 90% RH Non-Condensing
Environment For Dry Indoor Use Only
Mounting Single gang electrical box
STANDARD FEATURES
DESCRIPTION
PRODUCT LISTINGS
California
State Fire
Marshal 3042214
S5694 7300-0410:150
OPERATIONS
Programming and Configuration:
DIMENSIONS
Hochiki America Corporation FireNET Vapor - VPR-1 Specifications subject to change without notice.
TM
FireNET Vapor - VPR-1P
DESCRIPTION
The FireNET VaporTM VPR-1P detector is an air-sampling
system with an alarm sensitivity range from 0.0003 - 6.10
%/ft obscuration (0.001 - 20 %/m). This detector is classified
as a Very Early Warning Smoke Detector and can reliably
detect fire at an early stage and low to high concentrations
of smoke over an area of 9,150 ft2 (850 m2).
OPERATIONS
Programming and Configuration:
PRODUCT LISTINGS
California
State Fire
Marshal
7259:0410:0202
S3516
Continued on back.
DIMENSIONS
Hochiki America Corporation FireNET Vapor - VPR-1P Specifications subject to change without notice.
TM
FireNET Vapor - VPR-4 & VPR-6
DESCRIPTION
The FireNET VaporTM VPR-4 & VPR-6 detectors are multi-
channel air-sampling system with an alarm sensitivity range
from 0.0003 - 6.10 %/ft obscuration (0.001 - 20 %/m). These
detectors are classified as Very Early Warning Smoke
Detectors and can reliably detect fire at an early stage and
low to high concentrations of smoke over an area of 21,500
ft2 (2000 m2). As a multi-channel system, the VPR detector
is able to divide a protected space into sampling sectors,
enabling the localization of a fire for faster incident response.
OPERATIONS
Programming and Configuration:
DIMENSIONS
Hochiki America Corporation FireNET Vapor - VPR-4 & VPR-6 Specifications subject to change without notice.
FireNET VaporTM - VPR-15
DESCRIPTION
The FireNET VaporTM VPR-15 detector is an air-sampling
system with an alarm sensitivity range from 0.0003 - 6.10
%/ft obscuration (0.001 - 20 %/m). This detector is classified
as a Very Early Warning Smoke Detector and can reliably
detect fire at an early stage and low to high concentrations
of smoke over an area of 16,150 ft2 (1500 m2).
OPERATIONS
Programming and Configuration:
ORDERING INFORMAION
VPR-15 - Aspirating Smoke Detector
PRODUCT LISTINGS (0200-06080)
VPR-RM4 - 4 Channel Relay Module
California
(0400-03200)
State Fire
VPR-CLO8 - 8 Channel Analog Output Module
Marshal
7259:0410:0202 (0400-03210)
S3516 VPR-15-RD - Remote Display Module
(0500-06660)
Continued on back.
DIMENSIONS
Hochiki America Corporation FireNET Vapor - VPR-15 Specifications subject to change without notice.
TM
FireNET Vapor - VPR-SD1 & VPR-SD2
DESCRIPTION
The FireNET VaporTM VPR-SD1 & VPR-SD2 are aspirating
smoke detection systems that utilize an air-sampling pipe
network to draw air towards analog addressable point
detectors (ALK-V) installed inside a sealed enclosure. The
VPR-SD1 has one pipe inlet and provision for one or two
point detectors allowing redundant or double-knock
detection. The VPR-SD2 has two pipe inlets and provision
for two separate point detectors, each monitoring a separate
sampling pipe run, which allows for redundant or double-
knock detection.
• Listed to UL268 & UL268A • VPR-SD1 system - one or two spot (point) detectors
• Single or dual inlet fire detection (shared inlet)
• Multiple Piping options • VPR-SD2 system - two spot (point) detectors
• Multiple detection strategies (dual inlet)
• Pipe Length(s) up to164ft (50m) total per device
• Flexible Tube Length(s) up to 50ft (15m) maximum VPR-SD1 systems with one spot (point) detector are
• Microprocessor controlled capable of providing single area detection, but VPR-SD1
• High performance aspirator and VPR-SD2 systems with two detectors are able to
• Integral display and programmer provide a number of detection strategies. The table
• Field serviceable air filter below describes the recommended configuration
• Adjustable aspirator speed with airflow monitoring options for the selected detection strategy when two spot
• Compatible with FireNET and FireNET Plus FACP (point) detectors are installed into a VPR-SD system.
APPLICATIONS
The FireNET VaporTM VPR-SD1 & VPR-SD2 detectors are
configurable for a variety of environments, providing an
ideal fire detection solution for correctional facilities,
transformer vaults, cable tunnels, elevator machine rooms
and HVAC ducts.
*Subject to local codes and standards
Continued on back.
DIMENSIONS
Hochiki America Corporation FireNET Vapor - VPR-SD1 & VPR-SD2 Specifications subject to change without notice.
TM
FireNET Vapor - Accessories
SPECIFICATION
Remote Display Units
Supply Voltage 24 VDC
Communication RS485
4 Channel Relay Module
Relay Rating 2A, Form C Relay
8 Channel 4 to 20 mA Output Module
Output Rating 4 to 20 mA
Resolution 16 bit
DESCRIPTION
The FireNET Vapor TM accessories provide added
STANDARD FEATURES functionality for the FireNET Vapor series (VPR-1, VPR-4,
VPR-6 & VPR-15 only) of detectors. With the addition of
Remote Display Units remote display units and plug-in modules, extra functionality
• Remote monitoring, control and status annunciation such as remote monitoring and control, status annunciation,
4 Channel Relay Module extra relay contact outputs and analog outputs can be
integrated in one central device.
• Extra relay contact outputs
8 Channel 4 to 20 mA Output Module
• Multiple analog current outputs for retransmission of OPERATIONS
signals
Remote Display Units:
Expert Design and Technical Support for Your FireNET Vapor System
Who better to design and provide technical support for FireNET Vapor than the company that manufactures FireNET Vapor
aspirating smoke detection (ASD)? Our Application Engineers are ready to provide efficient and cost-effective design support for all of
your FireNET Vapor projects.
Design Services
Call ou
ur Tecchnical Servvice
es Departmen
nt at 1-8
800-84
45-6692
www.hochiki.com
OSID - Smoke Imaging Detection
DESCRIPTION
The OSID (Open-area Smoke Imaging Detection) by Xtralis
is a new innovation in projected beam smoke detection
technology. By using advanced dual wavelength projected
beams and optical imaging technology, OSID provides a
low-cost, reliable and easy to install solution that overcomes
typical beam detection issues such as false alarm incidents
and alignment difficulties.
OPERATIONS
Status information (Fire Alarm, Trouble and Power) is
communicated through the imager via Status LEDs,
dedicated Trouble and Alarm relays, and the remote
indicator interface. Specific Trouble (Fault) conditions are
identified through coded flashes of the Trouble LED.
CONFIGURATION OPTIONS
DIMENSIONS
SPECIFICATIONS
Models: 12-24SIR
Rated Voltage 10 - 28 VDC
Alarm Current 25mA
Standby Current 60uA
Relay Contact Voltage 30 VDC
Relay Contact Current 0.1A
Wiring Gauge 14 AWG - 22 AWG
Operating Temperature 40°F(4.4°C) ~ 100°F(37.8°C)
Relative Humidity 7.5 ~ 95%, Non-Condensing
Color Bone
Dimensions 5" D x 1.75" H
(127mm x 44.45mm)
Weight 9.4 oz
APPLICATION
STANDARD FEATURES
The 12-24SIR carbon monoxide (CO) detector is suited
• UL Listed for installations where CO may be expected. It responds
• 12/24VDC input power to the toxic CO gas that results from incomplete
• Reduces false alarm with its superior solid-state combustion, such as that emitted from appliances,
infrared sensor technology furnaces, fireplaces and auto exhaust. This detector is
• Low standby Current draw of 60uA designed to detect carbon monoxide gas from any source
• Bulit-in sounder with 85dB @ 10ft. of combustion.
• Temporal 4
• 6 year limited warranty
• Built-in self test
OPERATION
• Continuous supervision of CO sensor and alarm
circuit The 12-24SIR CO detector uses a solid-state infrared
• 1 Alarm Relay & 1 Trouble Relay (SIR) carbon monoxide sensor technology. The IR
• May be mounted on wall or ceiling detector monitors changes in photon transmittance of
the sensors, which are inversely related to levels of CO
concentrations in the air. For additonal information,
please refer to the 12-24SIR installation instruction
manual.
PRODUCT LISTINGS
• UL Listed (UL 2075)
• CSFM Approved
SPECIFICATIONS
Models: RFD-2000X
Rated Voltage 17 - 32 VDC
Alarm Current 20mA
Relay Contact Voltage 28 VDC max.
Relay Contact Current 2A max.
Detector Output 4-20mA
Wiring Gauge 14 AWG - 24 AWG shielded
Range of View 100 ft. (30m)
Field of View 90° Horizontal & Vertical
IP Rating IP67
Operating Temperature -40°C(-40°F) ~ 75°C(167°F)
Storage Temperature -50°C(-50°F) ~ 80°C(176°F)
Relative Humidity 95%, Non-Condensing
Color / Material Metal / Stainless Steel 316
Dimensions 5.3" W x 4.6" H x 4.7" D
(134mm x 117mm x 120mm)
STANDARD FEATURES Weight 3.4kg
• FM Approved
• Built-in Ultra violet and Infrared flame Sensors APPLICATION
• Explosion Proof (ATEX Ex d IIB + H2)
• Range of view up to 100ft. (30m) The RFD-2000X (explosion proof) Ultra Violet Infrared
• Reduces false alarm by built-in combination filters flame detector is suited for installation where open flame
and signal processing techniques fires may be expected. It responds to the light
• IP67 Rated for water and dust tight protection frequencies emitted from flames during combustion. This
• 4-20mA Output detector is used to detect flames from burning aviation
• 3 built-in relays (Alarm, Fault & Warning Alarm) fuels, butane, grain & feeds, hydrogen, paper, natural
gas, and petrol.
OPERATION
The RFD-2000X (Explosion proof) detector discriminates
between flames and other light sources by responding
only to set optical wavelenghts and flame flicker
frequencies. The built-in filters and signal processing
PRODUCT LISTINGS techniques help reduce false alarms due to flickering
sunlight. Rezontech's flame detector test unit (Test
• FM Approved (FM 3260) Lamp_TL-205) can be utilized to test the flame detector.
• ATEX Ex d IIB + H2 (Explosion proof)
Class I division 1 Group B,C and D
Class II division 1 Groups E, F and G ACCESSORIES
Class III
• IP67 (Water and dust tight)
• Sun Shield
• Air Shield
• Braket_BK-2
SPECIFICATIONS
Model Solo 200
Compatible Detector 2.5" - 4.5" dia.
Sizes (65mm - 110mm)
Color Black
Weight 2.42 lbs.
DESCRIPTION
Compatible with most detectors and sensors, the Solo
200 features color-coded heads which rotate to provide
a combination of settings and lock into place to fit
different sized detectors and sensors.
Shown without telescopic pole
STANDARD FEATURES
• Compatible with all Hochiki conventional detectors
and analog sensors.
• Universal Design - suits most detectors and
sensors of other manufacturers
• Color coded tri-grip heads are spring loaded
• Adjustable tri-grip
• Suitable for use on angled ceilings
• Lightweight
ACCESSORIES
Shown with teslescopic pole • Solo 100 - 15 ft. telescopic pole (sold separately)
• Solo 108 - 8 ft. telescopic pole (sold separately)
• Solo 101 - 4 ft. telescopic pole (sold separately)
ADT
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR DETECTOR BASE MODEL BASE ID
ID STYLE DET MODEL ID
ADT-XP XPM-8 A B;D 60 2.2K SIH-24F HD-3 HS-2-RB HB-10
ADT-XP XPM-8 A B;D 60 2.2K SIH-24F HD-3 HS-22D HB-3
ADT-XP XPM-8 A B;D 60 2.2K SIH-24F HD-3 HSB-220 HB-56
ADT-XP XPM-8 A B;D 60 2.2K SIH-24F HD-3 HSB-224 HB-53
ADT-XP XPM-8 A B;D 60 2.2K SIH-24F HD-3 YBA-M22 HB-3
ADT-XP XPM-8 A B;D 60 2.2K SLK-24F HD-3 HS-2-RB HB-10
ADT-XP XPM-8 A B;D 60 2.2K SLK-24F HD-3 HS-22D HB-3
ADT-XP XPM-8 A B;D 60 2.2K SLK-24F HD-3 HSB-220 HB-56
ADT-XP XPM-8 A B;D 60 2.2K SLK-24F HD-3 HSB-224 HB-53
ADT-XP XPM-8 A B;D 60 2.2K SLK-24F HD-3 YBA-M22 HB-3
ADT-XP XPM-8 A B;D 60 2.2K SLK-24FH HD-3 HS-2-RB HB-10
ADT-XP XPM-8 A B;D 60 2.2K SLK-24FH HD-3 HS-22D HB-3
ADT-XP XPM-8 A B;D 60 2.2K SLK-24FH HD-3 HSB-220 HB-56
ADT-XP XPM-8 A B;D 60 2.2K SLK-24FH HD-3 HSB-224 HB-53
ADT-XP XPM-8 A B;D 60 2.2K SLK-24FH HD-3 YBA-M22 HB-3
UNIMODE 4-16 IZ4;8W/WO IZE-A A B;D 35 4.7K SIH-24F HD-3 HS-2-RB HB-10
UNIMODE 4-16 IZ4;8W/WO IZE-A A B;D 35 4.7K SIH-24F HD-3 HS-22D HB-3
UNIMODE 4-16 IZ4;8W/WO IZE-A A B;D 35 4.7K SIH-24F HD-3 HSB-220 HB-56
UNIMODE 4-16 IZ4;8W/WO IZE-A A B;D 35 4.7K SIH-24F HD-3 HSB-224 HB-53
UNIMODE 4-16 IZ4;8W/WO IZE-A A B;D 35 4.7K SIH-24F HD-3 YBA-M22 HB-3
UNIMODE 4-16 IZ4;8W/WO IZE-A A B;D 35 4.7K SLK-24F HD-3 HS-2-RB HB-10
UNIMODE 4-16 IZ4;8W/WO IZE-A A B;D 35 4.7K SLK-24F HD-3 HS-22D HB-3
UNIMODE 4-16 IZ4;8W/WO IZE-A A B;D 35 4.7K SLK-24F HD-3 HSB-220 HB-56
UNIMODE 4-16 IZ4;8W/WO IZE-A A B;D 35 4.7K SLK-24F HD-3 HSB-224 HB-53
UNIMODE 4-16 IZ4;8W/WO IZE-A A B;D 35 4.7K SLK-24F HD-3 YBA-M22 HB-3
UNIMODE 4-16 IZ4;8W/WO IZE-A A B;D 35 4.7K SLK-24FH HD-3 HS-2-RB HB-10
UNIMODE 4-16 IZ4;8W/WO IZE-A A B;D 35 4.7K SLK-24FH HD-3 HS-22D HB-3
UNIMODE 4-16 IZ4;8W/WO IZE-A A B;D 35 4.7K SLK-24FH HD-3 HSB-220 HB-56
UNIMODE 4-16 IZ4;8W/WO IZE-A A B;D 35 4.7K SLK-24FH HD-3 HSB-224 HB-53
UNIMODE 4-16 IZ4;8W/WO IZE-A A B;D 35 4.7K SLK-24FH HD-3 YBA-M22 HB-3
UNIMODE 4-16 IZ4;9W/WO IZE-A A B;D 35 4.7K SLK-24F HD-3 YBA-M22 HB--3
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989
ADVANTOR
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR DETECTOR BASE MODEL BASE ID
ID STYLE DET MODEL ID
ULF 3000-24 N/A ULF1 A 10 6.8K SIH-24F HD-3 HS-200D HB-20
ULF 3000-24 N/A ULF1 A 10 6.8K SIH-24F HD-3 HS-220D HB-3
ULF 3000-24 N/A ULF1 A 10 6.8K SIH-24F HD-3 HS-221D HB-4
ULF 3000-24 N/A ULF1 A 10 6.8K SIH-24F HD-3 HS-224D HB-5
ULF 3000-24 N/A ULF1 A 10 6.8K SIH-24F HD-3 HSB-200 HB-55
ULF 3000-24 N/A ULF1 A 10 6.8K SIH-24F HD-3 HSB-220 HB-56
ULF 3000-24 N/A ULF1 A 10 6.8K SIH-24F HD-3 HSB-221 HB-54
ULF 3000-24 N/A ULF1 A 10 6.8K SIH-24F HD-3 HSB-224 HB-53
ULF 3000-24 N/A ULF1 A 10 6.8K SLK-24F HD-3 HS-200D HB-20
ULF 3000-24 N/A ULF1 A 10 6.8K SLK-24F HD-3 HS-220D HB-3
ULF 3000-24 N/A ULF1 A 10 6.8K SLK-24F HD-3 HS-221D HB-4
ULF 3000-24 N/A ULF1 A 10 6.8K SLK-24F HD-3 HS-224D HB-5
ULF 3000-24 N/A ULF1 A 10 6.8K SLK-24F HD-3 HSB-200 HB-55
ULF 3000-24 N/A ULF1 A 10 6.8K SLK-24F HD-3 HSB-220 HB-56
ULF 3000-24 N/A ULF1 A 10 6.8K SLK-24F HD-3 HSB-221 HB-54
ULF 3000-24 N/A ULF1 A 10 6.8K SLK-24F HD-3 HSB-224 HB-53
ULF 3000-24 N/A ULF1 A 10 6.8K SLK-24FH HD-3 HS-200D HB-20
ULF 3000-24 N/A ULF1 A 10 6.8K SLK-24FH HD-3 HS-220D HB-3
ULF 3000-24 N/A ULF1 A 10 6.8K SLK-24FH HD-3 HS-221D HB-4
ULF 3000-24 N/A ULF1 A 10 6.8K SLK-24FH HD-3 HS-224D HB-5
ULF 3000-24 N/A ULF1 A 10 6.8K SLK-24FH HD-3 HSB-200 HB-55
ULF 3000-24 N/A ULF1 A 10 6.8K SLK-24FH HD-3 HSB-220 HB-56
ULF 3000-24 N/A ULF1 A 10 6.8K SLK-24FH HD-3 HSB-221 HB-54
ULF 3000-24 N/A ULF1 A 10 6.8K SLK-24FH HD-3 HSB-224 HB-53
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989
ANSUL
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR DETECTOR BASE MODEL BASE ID
ID STYLE DET MODEL ID
AUTOPULSE FOUR 415413 REV.4 B 45 417213 DCA-135 N/A HSC-21L HB-60
AUTOPULSE FOUR 415413 REV.4 B 45 417213 DCA-190 N/A HSC-21L HB-60
AUTOPULSE FOUR 415413 REV.4 B 45 417213 SIH-24F HD-3 HS-21D HB-2
AUTOPULSE FOUR 415413 REV.4 B 45 417213 SIH-24F HD-3 HSB-21 HB-51
AUTOPULSE FOUR 415413 REV.4 B 45 417213 SIH-24F HD-3 HSC-224R HB-73
AUTOPULSE FOUR 415413 REV.4 B 45 417213 SLK-24F HD-3 YBA-M21 HB-2
AUTOPULSE FOUR 415413 REV.4 B 45 417213 SLK-24F HD-3 HS-21D HB-2
AUTOPULSE FOUR 415413 REV.4 B 45 417213 SLK-24F HD-3 HSB-21 HB-51
AUTOPULSE FOUR 415413 REV.4 B 45 417213 SLK-24F HD-3 HSB-21 HB-51
AUTOPULSE FOUR 415413 REV.4 B 45 417213 SLK-24F HD-3 HSC-224R HB-73
AUTOPULSE FOUR 415413 REV.4 B 45 417213 SLK-24FH HD-3 YBA-M21 HB-2
AUTOPULSE FOUR 415413 REV.4 B 45 417213 SLK-24FH HD-3 HS-21D HB-2
AUTOPULSE FOUR 415413 REV.4 B 45 417213 SLK-24FH HD-3 HSB-21 HB-51
AUTOPULSE FOUR 415413 REV.4 B 45 417213 SLK-24FH HD-3 HSC-224R HB-73
AUTOPULSE FOUR 415413 REV.4 B 45 417213 DCA-135 N/A YBA-M21 HB-2
AUTOPULSE FOUR 416610 REV. 1 D 45 417213 DCA-190 N/A HSC-21L HB-60
AUTOPULSE FOUR 416610 REV. 1 D 45 417213 SIH-24F HD-3 HSC-21L HB-60
AUTOPULSE FOUR 416610 REV. 1 D 45 417213 SIH-24F HD-3 HS-21D HB-2
AUTOPULSE FOUR 416610 REV. 1 D 45 417213 SIH-24F HD-3 HSB-21 HB-51
AUTOPULSE FOUR 416610 REV. 1 D 45 417213 SIH-24F HD-3 HSC-224R HB-73
AUTOPULSE FOUR 416610 REV. 1 D 45 417213 SLK-24F HD-3 YBA-M21 HB-2
AUTOPULSE FOUR 416610 REV. 1 D 45 417213 SLK-24F HD-3 HS-21D HB-2
AUTOPULSE FOUR 416610 REV. 1 D 45 417213 SLK-24F HD-3 HSB-21 HB-51
AUTOPULSE FOUR 416610 REV. 1 D 45 417213 SLK-24F HD-3 HSC-224R HB-73
AUTOPULSE FOUR 416610 REV. 1 D 45 417213 SLK-24F HD-3 YBA-M21 HB-2
AUTOPULSE FOUR 416610 REV. 1 D 45 417213 SLK-24FH HD-3 HS-21D HB-2
AUTOPULSE FOUR 416610 REV. 1 D 45 417213 SLK-24FH HD-3 HSB-21 HB-51
AUTOPULSE FOUR 416610 REV. 1 D 45 417213 SLK-24FH HD-3 HSC-224R HB-73
AUTOPULSE FOUR 416610 REV. 1 D 45 417213 SLK-24FH HD-3 YBA-M21 HB-2
AUTOPULSE IQ301 MMX-2, M3-TW A B 24 3.9K 1400 A N/A N/A
AUTOPULSE IQ301 MMX-2, M3-TW A B 20 3.9K 1451 A B401 A
AUTOPULSE IQ301 MMX-2, M3-TW A B 20 3.9K 1451 A B401B A
AUTOPULSE IQ301 MMX-2, M3-TW A B 1 3.9K 1451 A B406B A
AUTOPULSE IQ301 MMX-2, M3-TW A B 20 3.9K 1451DH A DH400 A
AUTOPULSE IQ301 MMX-2, M3-TW A B 20 3.9K 1851DH A DH1851DC A
AUTOPULSE IQ301 MMX-2, M3-TW A B 20 3.9K 2400 A N/A N/A
AUTOPULSE IQ301 MMX-2, M3-TW A B 1 3.9K 2400AIT A N/A N/A
AUTOPULSE IQ301 MMX-2, M3-TW A B 1 3.9K 2400AT A N/A N/A
AUTOPULSE IQ301 MMX-2, M3-TW A B 20 3.9K 2400TH A N/A N/A
AUTOPULSE IQ301 MMX-2, M3-TW A B 20 3.9K 2451 A B401 A
AUTOPULSE IQ301 MMX-2, M3-TW A B 20 3.9K 2451 A B401B A
AUTOPULSE IQ301 MMX-2, M3-TW A B 20 3.9K 2451 A DH400 A
AUTOPULSE IQ301 MMX-2, M3-TW A B 20 3.9K 2451TH A B401 A
AUTOPULSE IQ301 MMX-2, M3-TW A B 20 3.9K 2451TH A B401B A
AUTOPULSE IQ301 MMX-2, M3-TW A B 1 3.9K 2451TH A B406B A
AUTOPULSE IQ301 MMX-2, M3-TW A B 20 3.9K 2851DH A DH2851DC A
AUTOPULSE IQ301 MMX-2, M3-TW A B 1 3.9K SIH-24F HD-3 HS-2-RB HB-10
AUTOPULSE IQ301 MMX-2, M3-TW A B 25 3.9K SIH-24F HD-3 HS-22D HB-3
AUTOPULSE IQ301 MMX-2, M3-TW A B 25 3.9K SIH-24F HD-3 YBA-M22 HB-3
AUTOPULSE IQ301 MMX-2, M3-TW A B 1 3.9K SLD-24F HD-3 HS-2-RB HB-10
AUTOPULSE IQ301 MMX-2, M3-TW A B 25 3.9K SLK-24F HD-3 HS-22D HB-3
AUTOPULSE IQ301 MMX-2, M3-TW A B 1 3.9K SLK-24FH HD-3 HS-2-RB HB-10
AUTOPULSE IQ301 MMX-2, M3-TW A B 25 3.9K SLK-24FH HD-3 YBA-M22 HB-3
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989
C & K SYSTEMS
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR DETECTOR BASE MODEL BASE ID
ID STYLE DET MODEL ID
238,2316 ZONE 8 NONE A 10 2.2K SLK-12 HD-4 HSB-12-1 HB-80
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 5-Mar-2003
LISTED AFTER MARCH 1, 1989
CADDX
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR DETECTOR BASE MODEL BASE ID
ID STYLE DET MODEL ID
NX6, NX8 3800-0001 MDL NO A 20 680 OHMS SLR-835,-835W HD-3 NS4-220,NS6-220 HB-3
NX6,NX8 3800-0001 MDL NO A 20 680 OHMS SLR-835B-2 HD-6 N/A N/A
NX8-E 3800-0020 MDL NO A 20 680 OHMS SLR-835,-835W HD-3 NS4-220,NS6-220 HB-3
NX8-E 3800-0020 MDL NO A 20 680 OHMS SLR-835B-2 HD-6 N/A N/A
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989
CHEMETRON
2-Wire Compatibility Listings
PANEL MODEL ZONE MODELZONE LOOP MAX EOL DETECTOR DETECTOR BASE MODEL BASE ID
ID STYLE DET MODEL ID
MICRO 1-EV A A D 60 N/A SIH-24F HD-3 HS-220D HB-3
MICRO 1-EV A A D 60 N/A SIH-24F HD-3 HS-224D HB-5
MICRO 1-EV A A D 60 N/A SIH-24F HD-3 HS-224RB HB-12
MICRO 1-EV A A D 50 N/A SLK-24F HD-3 HS-220D HB-3
MICRO 1-EV A A D 50 N/A SLK-24F HD-3 HS-220RB HB-12
MICRO 1-EV A A D 50 N/A SLK-24F HD-3 HS-224D HB-5
MICRO 1-EV A A D 50 N/A SLK-24F HD-3 HS-224RB HB-14
MICRO 1-EV A A D 50 N/A SLK-24FH HD-3 HS-220D HB-3
MICRO 1-EV A A D 50 N/A SLK-24FH HD-3 HS-220RB HB-12
MICRO 1-EV A A D 50 N/A SLK-24FH HD-3 HS-224D HB-5
MICRO 1-EV A A D 50 N/A SLK-24FH HD-3 HS-224RB HB-14
MICRO1-EV N/A 4 B,D 14 2.7K OHM DCD-135, DCD-190 HD-3 HSC-224L HB-62
MICRO1-EV N/A 4 B,D 14 2.7K OHM DCD-135, DCD-190 HD-3 HSC-224L HB-62
MICRO1-EV N/A 4 B,D 14 2.7K OHM DFE-190 HD-3 HSC-220L HB-64
MICRO1-EV N/A 4 B,D 14 2.7K OHM DFE-190 HD-3 HSC-220L HB-64
MICRO1-EV N/A 4 B,D 14 2.7K OHM SIJ-24 HD-3 NS4-224,NS6-224 HB-5
MICRO1-EV N/A 4 B,D 14 2.7K OHM SIJ-24 HD-3 NS4-224,NS6-224 HB-5
MICRO1-EV N/A 4 B,D 14 2.7K OHM SLR-24 HD-3 NS4-224,NS6-224 HB-5
MICRO1-EV N/A 4 B,D 14 2.7K OHM SLR-24,-24H HD-3 HSC-220R HB-72
MICRO1-EV N/A 4 B,D 14 2.7K OHM SLR-24,-24H HD-3 NS4-220,NS6-220 HB-3
MICRO1-EV N/A 4 B,D 14 2.7K OHM SLR-24, SLR-24H HD-3 HSC-224R HB-73
MICRO1-EV N/A 4 B,D 14 2.7K OHM SLR-24, SLR-24H HD-3 HSC-224R HB-73
MICRO1-EV N/A 4 B,D 14 2.7K OHM SLR-24H HD-3 NS4-224,NS6-224 HB-5
MICRO1-EV N/A 4 B,D 14 2.7K OHM SLR-835B-2 HD-6 N/A N/A
MICRO1-EV CLASS N/A 4 B,D 10 2.7K OHM DCD-135 HD-3 HSC-220R HB-72
MICRO1-EV CLASS N/A 4 B,D 10 2.7K OHM DCD-135 HD-3 NS4-220,NS6-220 HB-3
MICRO1-EV CLASS N/A 4 B,D 10 2.7K OHM DCD-190 HD-3 HSC-220R HB-72
MICRO1-EV CLASS N/A 4 B,D 10 2.7K OHM DCD-190 HD-3 NS4-220,NS6-220 HB-3
MICRO1-EV CLASS N/A 4 B,D 10 2.7K OHM SIJ-24 HD-3 HSC-220R HB-72
MICRO1-EV CLASS N/A 4 B,D 10 2.7K OHM SIJ-24 HD-3 NS4-220,NS6-220 HB-3
MICRO1-EV CLASS N/A 4 B,D 10 2.7K OHM SLR-24 HD-3 HSC-220R HB-72
MICRO1-EV CLASS N/A 4 B,D 10 2.7K OHM SLR-24 HD-3 NS4-220,NS6-220 HB-3
SG N/A 1 B 33 4.7K OHM SIF-24F HD-3 HS-220D HB-3
SG N/A 1 B 33 4.7K OHM SIH-24F HD-3 HS-220D HB-3
SG N/A 1 B 33 4.7K OHM SLK-24F HD-3 HS-220D HB-3
SG N/A 1 B 33 4.7K OHM SLK-24FH HD-3 HS-220D HB-3
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989
DETECTION SYS.
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR DETECTOR BASE MODEL BASE ID
ID STYLE DET MODEL ID
DS9400I, DS9400M N/A A B 20 2.2K OHM DCD-135,-190 HD-3 HSC-220L HB-64
DS9400I, DS9400M N/A A B 20 2.2K OHM DCD-135,-190 HD-3 HSC-220R HB-72
DS9400I, DS9400M N/A A B 20 2.2K OHM DCD-135,-190 HD-3 NS4-220,NS6-220 HB-3
DS9400I, DS9400M N/A A B 20 2.2K OHM DCD-135,-190 HD-3 HSC-220L HB-64
DS9400I, DS9400M N/A A B 20 2.2K OHM SIJ-24 HD-3 HSC-220R HB-72
DS9400I, DS9400M N/A A B 20 2.2K OHM SIJ-24 HD-3 NS4-220,NS6-220 HB-3
DS9400I, DS9400M N/A A B 20 2.2K OHM SLR-24H,-24V HD-3 HSC-220R HB-72
DS9400I, DS9400M N/A A B 20 2.2K OHM SLR-24H,-24V HD-3 NS4-100,NS6-100 HB-55
DS9400I, DS9400M N/A A B 20 2.2K OHM SLR-24H,-24V HD-3 NS4-220,NS6-220 HB-3
DS9400I, DS9400M N/A A B 20 2.2K OHM SLR-835 HD-3 NS4-100,NS6-100 HB-55
DS9400I, DS9400M N/A A B 20 2.2K OHM SLR-835 HD-3 NS4-220,NS6-220 HB-3
DS9400I, DS9400M N/A A B 20 2.2K OHM SLR-835B-2 HD-6 N/A N/A
DS9400I, DS9400M N/A A B 20 2.2K OHM SLR-835H HD-5 HSC-220R HB-72
DS9400I, DS9400M N/A A B 20 2.2K OHM SLR-835H HD-5 NS4-220,NS6-220 HB-3
DS9400I, DS9400M N/A A B 1 2.2K OHM SLR-835,-835W HD-5 SBC-2R,SBC-2RW HB-85
DS9400I, DS9400M N/A A B 1 2.2K OHM SIJ-24 HD-3 SBC-2 HB-85
DS9400I, DS9400M N/A A B 1 2.2K OHM SLR-24V HD-3 SBC-2 HB-85
DS9400I, DS9400M N/A A B 1 2.2K OHM SLR-24V HD-3 SBC-2R HB-86
UPDATED 9/11/03
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989
DIGITAL MONITOR
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR DETECTOR BASE MODEL BASE ID
ID STYLE DET MODEL ID
XR5FC 2--5 A A 22 3.3k SLK12 HD-4 HSB-12-1,-12-1N HB-80
XR5FC 2--5 A A 7 3.3k SLK-835,-835H HD-5 HSB-200,-200N HB-55
XR5SL 2--5 A A 22 3.3k SLK-12 HD-4 HSB-12-1,-12-1N HB-80
XR5SL 2--5 A A 7 3.3k SLK-835,-835H HD-5 HSB-200,-200N HB-55
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989
DMP
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR DETECTOR BASE MODEL BASE ID
ID STYLE DET MODEL ID
XR10 10 ON XR10 A A 22 3.3K SLK-12 HD-4 HSB-12-1,-12-1N HB-80
XR10 10 ON XR10 A A 7 3.3K SLK-835,-835H HD-5 HSB-200,-200N HB-55
XR10 10 ON XR10 A A 7 3.3K SLR-835 HD-3 NS6-100 HB-55
XR20 10 ON XR20 A A 22 3.3K SLK-12 HD-4 HSB-12-1,-12-1N HB-80
XR20 10 ON XR20 A A 7 3.3K SLK-835,-835H HD-5 HSB-200,-200N HB-55
XR20 10 ON XR20 A A 7 3.3K SLR-835 HD-3 NS6-100 HB-55
XR20 10 ON XR20 A A 7 3.3K SLR-835B HD-6 NA NA
XR20 715 A A 7 3.3K SLR-835 HD-3 NS6-100 HB-55
XR20 715,-16 A A 7 3.3K SLR-835B HD-6 NA NA
XR20 715,-16,-8 A A 7 3.3K SLK-835,-835H HD-5 HSB-200,-200N HB-55
XR20 715,-16-,-8 A A 22 3.3K SLK-12 HD-4 HSB-12-1,-12-1N HB-80
XR20 715-16 A A 7 3.3K SLR-835 HD-3 NS6-100 HB-55
XR20 715-8 A A 7 3.3K SLR-835 HD-3 NS6-100 HB-55
XR20 715-8 A A 7 3.3K SLR-835B HD-6 NA NA
XR200 10 ON XR200 A A 7 3.3K SLK-835,-835H HD-5 HSB-200,-200N HB-55
XR200 715 A A 22 3.3K SLK-12 HD-4 HSB-12-1,-12-1N HB-80
XR200 715 A A 7 3.3K SLK-835,-835H HD-5 HSB-200,-200N HB-55
XR200 715 OR Z 9 &10 A A 22 3.3K SLK-12 HD-4 HSB-12-1,-12-1N HB-80
XR200 715, 715-16 A A 7 3.3K SLK-835,-835H HD-5 HSB-200,-200N HB-55
XR200 715,-16 A A 7 3.3K SLR-835 HD-3 NS6-100 HB-55
XR200 715,-16 A A 7 3.3K SLR-835B HD-6 NA NA
XR200 715,-16,-8 A A 22 3.3K SLK-12 HD-4 HSB-12-1,-12-1N HD-4
XR200 715-8 A A 7 3.3K SLK-835,-835H HD-5 HSB-200,-200N HB-55
XR200 715-8 A A 7 3.3K SLR-835 HD-3 NS6-100 HB-55
XR200 9 & 10 ON XR200 A A 22 3.3K SLK-12 HD-4 HSB-12-1,-12-1N HB-80
XR200 9 ON XR200 A A 7 3.3K SLK-835,-835H HD-5 HSB-200,-200N HB-55
XR200 9,10 ON XR200 A A 7 3.3K SLR-835 HD-3 NS6-100 HB-55
XR200 9,10 ON XR200 A A 7 3.3K SLR-835B HD-6 NA NA
XR200 XR200 A A 22 3.3K SLK-12 HD-4 HSB-12-1,-12-1N HB-80
XR200 XR200 A A 7 3.3K SLK-835,-835H HD-5 HSB-200,-200N HB-55
XR5FC 2-5 ON XR5FC A A 22 3.3K SLK-12 HD-4 HSB-12-1,-12-1N HB-80
XR5FC 2-5 ON XR5FC A A 7 3.3K SLK-835,-835H HD-5 HSB-200,-200N HB-55
XR5FC 2-5 ON XR5FC A A 7 3.3K SLR-835 HD-6 NA NA
XR5FC 2-5 ON XR5FC A A 7 3.3K SLR-835 HD-3 NS6-100 HB-55
XR5SL 2-5 ON XR5SL A A 22 3.3K SLK-12 HD-4 HSB-12-1,-12-1N HB-80
XR5SL 2-5 ON XR5SL A A 7 3.3K SLK-835,-835H HD-5 HSB-200,-200N HB-55
XR5SL 2-5 ON XR5SL A A 7 3.3K SLR-835 HD-3 NS6-100 HB-55
XR5SL 2-5 ON XR5SL A A 7 3.3K SLR-835B HD-6 NA NA
XR6 6 ON XR6 A A 7 3.3K SLR-835 HD-3 NS6-100 HB-55
XR6 6 ON XR6 A A 7 3.3K SLR-835B HD-6 NA NA
XR6 715 A A 7 3.3K SLR-835B HD-6 NA NA
XR6 715 ON XR6 A A 7 3.3K SLR-835 HD-3 NS6-100 HB-55
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989
DSC
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR DETECTOR BASE MODEL BASE ID
ID STYLE DET MODEL ID
PC1555 UA000 PC15-1 B 30 2.2K OHM SLR-835, 835W HD-3 NS4-220,NS6-220 HB-3
PC1555 UA000 PC15-1 B 30 2.2K OHM SLR-835B-2 HD-6 N/A N/A
PC1555 UA000 PC15-1 B 30 2.2K OHM SLR-835BH-2 HD-6 N/A N/A
PC4020CF PC4701 PM-2 B 30 2.2K OHM SLR-835, 835W HD-3 NS4-220,NS6-220 HB-3
PC4020CF PC4701 PM-2 B 30 2.2K OHM SLR-835B-2 HD-6 N/A N/A
PC4020CF PC4701 PM-2 B 30 2.2K OHM SLR-835BH-2 HD-6 N/A N/A
PC5010 PC5010 PC5-1 B 30 2.2K OHM SLR-835, 835W HD-3 NS4-220,NS6-220 HB-3
PC5010 PC5010 PC5-1 B 30 2.2K OHM SLR-835B-2 HD-6 N/A N/A
PC5010 PC5010 PC5-1 B 30 2.2K OHM SLR-835BH-2 HD-6 N/A N/A
PC5020 PC5020 PC5-2 B 30 2.2K OHM SLR-835, 835W HD-3 NS4-220,NS6-220 HB-3
PC5020 PC5020 PC5-2 B 30 2.2K OHM SLR-835B-2 HD-6 N/A N/A
PC5020 PC5020 PC5-2 B 30 2.2K OHM SLR-835BH-2 HD-6 N/A N/A
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989
EDWARDS
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR DETECTOR BASE MODEL BASE ID
ID STYLE DET MODEL ID
5783B N/A 001 B 33 4.7K OHM SIF-24F HD-2 HS-220D HB-3
5783B N/A 001 B 33 4.7K OHM SIH-24F HD-3 HS-220D HB-3
5783B N/A 001 B 33 4.7K OHM SLK-24F HD-3 HS-220D HB-3
5783B N/A 001 B 33 4.7K OHM SLK-24FH HD-3 HS-220D HB-3
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989
F.A.S.T. INC.
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
RZB12-6MFC 240204 5389 B 15 PN260001 SIF-24F HD-2 HS-22D HB-3
RZB12-6MFC 240204 5389 B 15 PN260001 SIF-24F HD-3 YBA-M22 HB-3
RZB12-6MFC 240204 5389 B 15 PN260001 SLK-24F HD-3 HS-22D HB-3
RZB12-6MFC 240204 5389 B 15 PN260001 SLK-24F HD-3 YBA-M22 HB-3
RZB12-6MFC 240204 5389 B 15 PN260001 SLK-24FH HD-3 HS-22D HB-3
RZB12-6MFC 240204 5389 B 15 PN260001 SLK-24FH HD-3 YBA-M22 HB-3
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989
FARADAY
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
852 N/A FOS1 B 30 3.9K OHM DCA-135 N/A HS-224L HB-18
852 N/A FOS1 B 30 3.9K OHM DCA-190 N/A HS-224L HB-18
852 N/A FOS1 B 30 3.9K OHM DCA-190 N/A HS-224L HB-18
852 N/A FOS1 B 30 3.9K OHM DFE-135 N/A HS-224L HB-18
852 N/A FOS1 B 30 3.9K OHM DFE-190 N/A HS-224L HB-18
854 N/A FOS1 B 30 3.9K OHM DCA-135 N/A HS-224L HB-18
854 N/A FOS1 B 30 3.9K OHM DCA-190 N/A HS-224L HB-18
854 N/A FOS1 B 30 3.9K OHM DFE-135 N/A HS-224L HB-18
854 N/A FOS1 B 30 3.9K OHM DFE-190 N/A HS-224L HB-18
15108AL N/A FOS2 B 30 5.6K OHM DCA-135 N/A HS-224L HB-18
15108AL N/A FOS2 D 30 N/A DCA-135 N/A HS-224L HB-18
15108AL N/A FOS2 B 30 5.6K OHM DCA-190 N/A HS-224L HB-18
15108AL N/A FOS2 D 30 N/A DCA-190 N/A HS-224L HB-18
15108AL N/A FOS2 B 30 5.6K OHM DFE-135 N/A HS-224L HB-18
15108AL N/A FOS2 B 30 5.6K OHM DFE-135 N/A HS-224L HB-18
15108AL N/A FOS2 D 30 N/A DFE-135 N/A HS-224L HB-18
15108AL N/A FOS2 D 30 N/A DFE-135 N/A HS-224L HB-18
15108AL N/A FOS2 B 30 5.6K OHM DFE-190 N/A HS-224L HB-18
15108AL N/A FOS2 B 30 5.6K OHM DFE-190 N/A HS-224L HB-18
15108AL N/A FOS2 D 30 N/A DFE-190 N/A HS-224L HB-18
15108AL N/A FOS2 D 30 N/A DFE-190 N/A HS-224L HB-18
15112AL N/A FOS2 B 30 5.6K OHM DCA-135 N/A HS-224L HB-18
15112AL N/A FOS2 B 30 5.6K OHM DCA-135 N/A HS-224L HB-18
15112AL N/A FOS2 D 30 N/A DCA-135 N/A HS-224L HB-18
15112AL N/A FOS2 D 30 N/A DCA-135 N/A HS-224L HB-18
15112AL N/A FOS2 B 30 5.6K OHM DCA-190 N/A HS-224L HB-18
15112AL N/A FOS2 B 30 5.6K OHM DCA-190 N/A HS-224L HB-18
15112AL N/A FOS2 D 30 N/A DCA-190 N/A HS-224L HB-18
15112AL N/A FOS2 D 30 N/A DCA-190 N/A HS-224L HB-18
15112AL N/A FOS2 B 30 5.6K OHM DFE-135 N/A HS-224L HB-18
15112AL N/A FOS2 B 30 5.6K OHM DFE-135 N/A HS-224L HB-18
15112AL N/A FOS2 D 30 N/A DFE-135 N/A HS-224L HB-18
15112AL N/A FOS2 D 30 N/A DFE-135 N/A HS-224L HB-18
15112AL N/A FOS2 B 30 5.6K OHM DFE-190 N/A HS-224L HB-18
15112AL N/A FOS2 B 30 5.6K OHM DFE-190 N/A HS-224L HB-18
15112AL N/A FOS2 D 30 N/A DFE-190 N/A HS-224L HB-18
15112AL N/A FOS2 D 30 N/A DFE-190 N/A HS-224L HB-18
15116AL N/A FOS2 B 30 5.6K OHM DCA-135 N/A HS-224L HB-18
15116AL N/A FOS2 B 30 5.6K OHM DCA-135 N/A HS-224L HB-18
15116AL N/A FOS2 D 30 N/A DCA-135 N/A HS-224L HB-18
15116AL N/A FOS2 D 30 N/A DCA-135 N/A HS-224L HB-18
15116AL N/A FOS2 B 30 5.6K OHM DCA-190 N/A HS-224L HB-18
15116AL N/A FOS2 B 30 5.6K OHM DCA-190 N/A HS-224L HB-18
15116AL N/A FOS2 D 30 N/A DCA-190 N/A HS-224L HB-18
15116AL N/A FOS2 D 30 N/A DCA-190 N/A HS-224L HB-18
15116AL N/A FOS2 B 30 5.6K OHM DFE-135 N/A HS-224L HB-18
15116AL N/A FOS2 B 30 5.6K OHM DFE-135 N/A HS-224L HB-18
15116AL N/A FOS2 D 30 N/A DFE-135 N/A HS-224L HB-18
15116AL N/A FOS2 D 30 N/A DFE-135 N/A HS-224L HB-18
15116AL N/A FOS2 B 30 5.6K OHM DFE-190 N/A HS-224L HB-18
15116AL N/A FOS2 B 30 5.6K OHM DFE-190 N/A HS-224L HB-18
15116AL N/A FOS2 D 30 N/A DFE-190 N/A HS-224L HB-18
15116AL N/A FOS2 D 30 N/A DFE-190 N/A HS-224L HB-18
19000A N/A B B 30 5.6K OHM DCA-135 N/A HS-224L HB-18
19000A N/A B B 30 5.6K OHM DCA-135 N/A HS-224L HB-18
19000A N/A B D 30 N/A DCA-135 N/A HS-224L HB-18
19000A N/A B D 30 N/A DCA-135 N/A HS-224L HB-18
19000A N/A B B 30 5.6K OHM DCA-190 N/A HS-224L HB-18
19000A N/A B B 30 5.6K OHM DCA-190 N/A HS-224L HB-18
19000A N/A B D 30 N/A DCA-190 N/A HS-224L HB-18
19000A N/A B D 30 N/A DCA-190 N/A HS-224L HB-18
19000A N/A B B 30 5.6K OHM DFE-135 N/A HS-224L HB-18
19000A N/A B B 30 5.6K OHM DFE-135 N/A HS-224L HB-18
19000A N/A B D 30 N/A DFE-135 N/A HS-224L HB-18
19000A N/A B D 30 N/A DFE-135 N/A HS-224L HB-18
19000A N/A B B 30 5.6K OHM DFE-190 N/A HS-224L HB-18
19000A N/A B B 30 5.6K OHM DFE-190 N/A HS-224L HB-18
19000A N/A B D 30 N/A DFE-190 N/A HS-224L HB-18
Page 1 of 2
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989
Page 2 of 2
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989
FIKE
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
RHINO 10-2141, 10-2144 DET220 B, D 50 3.3K OHM DFE-135, -190 N/A HSC-220L HB-64
RHINO 10-2141, 10-2144 DET220 B, D 50 3.3K OHM SLR-24H HD-3 HSC-220R HB-72
RHINO 10-2141, 10-2144 DET220 B, D 50 3.3K OHM SLR-24H HD-3 NS4-220, NS6-220 HB-3
RHINO 10-050 10-2141, -2144 DET220 B, D 50 3.3K OHM SLR-835B-2 HD-6 N/A N/A
RHINO 10-050 10-2141, 10-2144 DET470 B 30 3.3K OHM DCD-135 HD-3 HSC-220R HB-72
RHINO 10-050 10-2141, 10-2144 DET470 B 30 3.3K OHM DCD-135 HD-3 HSC-221R HB-71
RHINO 10-050 10-2141, 10-2144 DET470 B 30 3.3K OHM DCD-135 HD-3 HSC-224R HB-73
RHINO 10-050 10-2141, 10-2144 DET470 B 30 3.3K OHM DCD-135 HD-3 NS4-220, NS6-220 HB-3
RHINO 10-050 10-2141, 10-2144 DET470 B 30 3.3K OHM DCD-135 HD-3 NS4-221, NS6-221 HB-4
RHINO 10-050 10-2141, 10-2144 DET470 B 30 3.3K OHM DCD-135 HD-3 NS4-224, NS6-224 HB-5
RHINO 10-050 10-2141, 10-2144 DET470 B 30 3.3K OHM DCD-190 HD-3 HSC-220R HB-72
RHINO 10-050 10-2141, 10-2144 DET470 B 30 3.3K OHM DCD-190 HD-3 HSC-221R HB-71
RHINO 10-050 10-2141, 10-2144 DET470 B 30 3.3K OHM DCD-190 HD-3 HSC-224R HB-73
RHINO 10-050 10-2141, 10-2144 DET470 B 30 3.3K OHM DCD-190 HD-3 NS4-220, NS6-220 HB-3
RHINO 10-050 10-2141, 10-2144 DET470 B 30 3.3K OHM DCD-190 HD-3 NS4-221, NS6-221 HB-4
RHINO 10-050 10-2141, 10-2144 DET470 B 30 3.3K OHM DCD-190 HD-3 NS4-224, NS6-224 HB-5
RHINO 10-050 10-2141, 10-2144 DET470 B 30 3.3K OHM SIJ-24 HD-3 HSC-220R HB-72
RHINO 10-050 10-2141, 10-2144 DET470 B 30 3.3K OHM SIJ-24 HD-3 HSC-221R HB-71
RHINO 10-050 10-2141, 10-2144 DET470 B 30 3.3K OHM SIJ-24 HD-3 HSC-224R HB-73
RHINO 10-050 10-2141, 10-2144 DET470 B 30 3.3K OHM SIJ-24 HD-3 NS4-220, NS6-220 HB-3
RHINO 10-050 10-2141, 10-2144 DET470 B 30 3.3K OHM SIJ-24 HD-3 NS4-221, NS6-221 HB-4
RHINO 10-050 10-2141, 10-2144 DET470 B 30 3.3K OHM SIJ-24 HD-3 NS4-224, NS6-224 HB-5
RHINO 10-050 10-2141, 10-2144 DET470 B 30 3.3K OHM SLR-24 HD-3 HSC-220R HB-72
RHINO 10-050 10-2141, 10-2144 DET470 B 30 3.3K OHM SLR-24 HD-3 HSC-221R HB-71
RHINO 10-050 10-2141, 10-2144 DET470 B 30 3.3K OHM SLR-24 HD-3 HSC-224R HB-73
RHINO 10-050 10-2141, 10-2144 DET470 B 30 3.3K OHM SLR-24 HD-3 NS4-220, NS6-220 HB-3
RHINO 10-050 10-2141, 10-2144 DET470 B 30 3.3K OHM SLR-24 HD-3 NS4-221, NS6-221 HB-4
RHINO 10-050 10-2141, 10-2144 DET470 B 30 3.3K OHM SLR-24 HD-3 NS4-224, NS6-224 HB-5
SHP 10-051 10-2171 102171 B 25 4.3K OHM DCD-135 HD-3 HSC-220R HB-72
SHP 10-051 10-2171 102171 B 25 4.3K OHM DCD-135 HD-3 HSC-221R HB-71
SHP 10-051 10-2171 102171 B 25 4.3K OHM DCD-135 HD-3 HSC-224R HB-73
SHP 10-051 10-2171 102171 B 25 4.3K OHM DCD-135 HD-3 NS4-220, NS6-220 HB-3
SHP 10-051 10-2171 102171 B 25 4.3K OHM DCD-135 HD-3 NS4-221, NS6-221 HB-4
SHP 10-051 10-2171 102171 B 25 4.3K OHM DCD-135 HD-3 NS4-224, NS6-224 HB-5
SHP 10-051 10-2171 MDL. NO B, D 25 4.3K OHM DCD-135, DCD-190 HD-3 NS4-221, NS6-221 HB-4
SHP 10-051 10-2171 102171 B 25 4.3K OHM DCD-190 HD-3 HSC-220R HB-72
SHP 10-051 10-2171 102171 B 25 4.3K OHM DCD-190 HD-3 HSC-221R HB-71
SHP 10-051 10-2171 102171 B 25 4.3K OHM DCD-190 HD-3 HSC-224R HB-73
SHP 10-051 10-2171 102171 B 25 4.3K OHM DCD-190 HD-3 NS4-220, NS6-220 HB-3
SHP 10-051 10-2171 102171 B 25 4.3K OHM DCD-190 HD-3 NS4-221, NS6-221 HB-4
SHP 10-051 10-2171 102171 B 25 4.3K OHM DCD-190 HD-3 NS4-224, NS6-224 HB-5
SHP 10-051 10-2171 102171 B 25 4.3K OHM SIJ-24 HD-3 HSC-220R HB-72
SHP 10-051 10-2171 102171 B 25 4.3K OHM SIJ-24 HD-3 HSC-221R HB-71
SHP 10-051 10-2171 102171 B 25 4.3K OHM SIJ-24 HD-3 HSC-224R HB-73
SHP 10-051 10-2171 102171 B 25 4.3K OHM SIJ-24 HD-3 NS4-220, NS6-220 HB-3
SHP 10-051 10-2171 MDL. NO B, D 25 4.3K OHM SIJ-24 HD-3 NS4-221, NS6-221 HB-4
SHP 10-051 10-2171 102171 B 25 4.3K OHM SIJ-24 HD-3 NS4-221, NS6-221 HB-4
SHP 10-051 10-2171 102171 B 25 4.3K OHM SIJ-24 HD-3 NS4-224, NS6-224 HB-5
SHP 10-051 10-2171 102171 B 25 4.3K OHM SLR-24 HD-3 HSC-220R HB-72
SHP 10-051 10-2171 102171 B 25 4.3K OHM SLR-24 HD-3 HSC-221R HB-71
SHP 10-051 10-2171 102171 B 25 4.3K OHM SLR-24 HD-3 HSC-224R HB-73
SHP 10-051 10-2171 102171 B 25 4.3K OHM SLR-24 HD-3 NS4-220, NS6-220 HB-3
SHP 10-051 10-2171 102171 B 25 4.3K OHM SLR-24 HD-3 NS4-221, NS6-221 HB-4
SHP 10-051 10-2171 MDL NO B, D 25 4.3K OHM SLR-24 HD-3 NS4-221, NS6-221 HB-4
SHP 10-051 10-2171 102171 B 25 4.3K OHM SLR-24 HD-3 NS4-224, NS6-224 HB-5
SHP 10-051 10-2171 MDL. NO B, D 25 4.3K OHM SLR-835B-2 HD-6 N/A N/A
10-038 N/A 038000 B 87 1.5K OHM SIH-24F HD-3 HS-220D HB-3
10-038 N/A 038000 D 87 N/A SIH-24F HD-3 HS-220D HB-3
10-038 N/A 038000 B 87 1.5K OHM SIH-24F HD-3 YBA-M220 HB-3
10-038 N/A 038000 D 87 N/A SIH-24F HD-3 YBA-M220 HB-3
10-038 N/A 038000 B 87 1.5K OHM SLK-24F HD-3 HS-220D HB-3
10-038 N/A 038000 D 87 N/A SLK-24F HD-3 HS-220D HB-3
10-038 N/A 038000 D 87 N/A SLK-24F HD-3 HS-220RB HB-12
10-038 N/A 038000 B 87 1.5K OHM SLK-24F HD-3 HS-220RB HB-12
10-038 N/A 038000 B 87 1.5K OHM SLK-24F HD-3 YBA-M220 HB-3
10-038 N/A 038000 D 87 N/A SLK-24F HD-3 YBA-M220 HB-3
10-039 N/A 038000 D 87 N/A SIH-24F HD-3 HS-220D HB-3
10-039 N/A 038000 B 87 1.5K OHM SIH-24F HD-3 HS-220D HB-3
Page 1 of 2
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989
Page 2 of 2
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989
FIRELITE
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
MP-12 N/A A B, D 11 2.2K LPSD-12 HD-4 BLP-12-R HB-83
MP-12 N/A A B, D 11 2.2K LPSD-12 HD-4 BLP-12-RN HB-83
MP-12 N/A A B, D 15 2.2K OHM SLR-835 HD-3 NS4-220, NS6-220 HB-3
MP-12 N/A A B, D 15 2.2K OHM SLR-835B-2 HD-6 N/A N/A
MP-24 N/A A B 15 2.2K OHM DCD-135, -190 HD-3 HSC-220L HB-64
MP-24 N/A A B 15 2.2K OHM DCD-135, -190 HD-3 HSC-220R HB-72
MP-24 N/A A B 15 2.2K OHM DCD-135, -190 HD-3 NS4-220, NS6-220 HB-3
MP-24 N/A A B 15 2.2K OHM DFE-135, -190 HD-3 HSC-220L HB-64
MP-24 N/A A B 15 2.2K OHM SIJ-24 HD-3 HSC-220R HB-72
MP-24 N/A A B 15 2.2K OHM SIJ-24 HD-3 NS4-220, NS6-220 HB-3
MP-24 N/A A B 15 2.2K OHM SLR-24H, -24V HD-3 HSC-220R HB-72
MP-24 N/A A B 15 2.2K OHM SLR-24H, -24V HD-3 NS4-220, NS6-220 HB-3
MP-24 N/A A B 15 2.2K OHM SLR-835 HD-3 NS4-220, NS6-220 HB-3
MP-24 N/A A B 15 2.2K OHM SLR-835B-2 HD-6 N/A N/A
MS-4012 N/A A B 11 2.2K LPSD-12 HD-4 BLP-12-R HB-83
MS-4012 N/A A B 11 2.2K LPSD-12 HD-4 BLP-12-RN HB-83
MS-4412B N/A A B 15 2.2K OHM DCD-135, -190 HD-3 HSC-220L HB-64
MS-4412B N/A A B 15 2.2K OHM DCD-135, -190 HD-3 HSC-220R HB-72
MS-4412B N/A A B 15 2.2K OHM DCD-135, -190 HD-3 NS4-220, NS6-220 HB-3
MS-4412B N/A A B 15 2.2K OHM DFE-135, -190 HD-3 HSC-220L HB-64
MS-4412B N/A A B 15 2.2K LPSD-12 HD-4 BLP-12-R HB-83
MS-4412B N/A A B 15 2.2K LPSD-12 HD-4 BLP-12-RN HB-83
MS-4412B N/A A B 15 2.2K OHM SIJ-24 HD-3 HSC-220R HB-72
MS-4412B N/A A B 15 2.2K OHM SIJ-24 HD-3 NS4-220, NS6-220 HB-3
MS-4412B N/A A B 15 2.2K OHM SLR-24H, -24V HD-3 HSC-220R HB-72
MS-4412B N/A A B 15 2.2K OHM SLR-24H, -24V HD-3 NS4-220, NS6-220 HB-3
MS-4412B N/A A B 15 2.2K OHM SLR-835 HD-3 NS4-220, NS6-220 HB-3
MS-4412B N/A A B 15 2.2K OHM SLR-835B-2 HD-6 N/A N/A
MS4412B N/A A B 10 2.2K OHM SLR-835BH-2 HD-6 N/A N/A
MS4412B N/A A B 10 2.2K OHM SLR-835H HD-5 NS4-220,NS6-220 HB-3
MS-5012 N/A A B 15 2.2K OHM DCD-135, -190 HD-3 HSC-220L HB-64
MS-5012 N/A A B 15 2.2K OHM DCD-135, -190 HD-3 HSC-220R HB-72
MS-5012 N/A A B 15 2.2K OHM DCD-135, -190 HD-3 NS4-220, NS6-220 HB-3
MS-5012 N/A A B 15 2.2K OHM DFE-135, -190 HD-3 HSC-220L HB-64
MS-5012 N/A A B 15 2.2K OHM SIJ-24 HD-3 HSC-220R HB-72
MS-5012 N/A A B 15 2.2K OHM SIJ-24 HD-3 NS4-220, NS6-220 HB-3
MS-5012 N/A A B 15 2.2K OHM SLR-24H, -24V HD-3 HSC-220R HB-72
MS-5012 N/A A B 15 2.2K OHM SLR-24H, -24V HD-3 NS4-220, NS6-220 HB-3
MS-5012 N/A A B 10 2.2K OHM SLR-835H HD-5 NS4-220,NS6-220 HB-3
MS-5012 N/A A B 15 2.2K OHM SLR-835 HD-3 NS4-220, NS6-220 HB-3
MS-5012 N/A A B 15 2.2K OHM SLR-835B-2 HD-6 N/A N/A
MS-5012 ZONE 2, 3 A B 11 2.2K LPSD-12 HD-4 BLP-12-R HB-83
MS-5012 ZONE 2, 3 A B 11 2.2K LPSD-12 HD-4 BLP-12-RN HB-83
MS-5024, -5024UD N/A A B, D 15 4.7K OHM DCD-135, -190 HD-3 HSC-220L HB-64
MS-5024, -5024UD N/A A B, D 15 4.7K OHM DCD-135, -190 HD-3 HSC-220R HB-72
MS-5024, -5024UD N/A A B, D 15 4.7K OHM DCD-135, -190 HD-3 NS4-220, NS6-220 HB-3
MS-5024, -5024UD N/A A B, D 15 4.7K OHM DFE-135, -190 HD-3 HSC-220L HB-64
MS-5024, -5024UD N/A A B, D 15 4.7K OHM SIJ-24 HD-3 HSC-220R HB-72
MS-5024, -5024UD N/A A B, D 15 4.7K OHM SIJ-24 HD-3 NS4-220, NS6-220 HB-3
MS-5024, -5024UD N/A A B, D 15 4.7K OHM SLR-24H, -24V HD-3 HSC-220R HB-72
MS-5024, -5024UD N/A A B, D 15 4.7K OHM SLR-24H, -24V HD-3 NS4-220, NS6-220 HB-3
MS-5024, -5024UD N/A A B, D 15 4.7K OHM SLR-835 HD-3 NS4-220, NS6-220 HB-3
MS-5024, -5024UD N/A A B, D 15 4.7K OHM SLR-835B-2 HD-6 N/A N/A
MS-5024,-5024UD N/A A B 10 4.7K OHM SLR-835H HD-5 HSC-220R HB-72
MS-5024,-5024UD N/A A B 10 4.7K OHM SLR-835H HD-5 NS4-220,NS6-220 HB-3
MS-5024,-5024UD N/A A B,D 1 4.7K OHM SLR-835,-835W HD-5 SBC-2,SBC-2W HB-85
MS-5024,-5024UD N/A A B,D 1 4.7K OHM SLR-835,-835W HD-5 SBC-2R,SBC-2RW HB-85
MS-5024,-5024UD N/A A B,D 1 4.7K OHM SLR-835H,-835HW HD-5 SBC-2R,SBC-2RW HB-85
MS-5024,-5024UD N/A A B,D 1 4.7K OHM SLR-835H,-835HW HD-5 SBC-2,SBC-2W HB-85
MS-5024,-5024UD N/A A B,D 1 4.7K OHM SIJ-24 HD-3 SBC-2 HB-85
MS-5024,-5024UD N/A A B,D 1 4.7K OHM SLR-24V HD-3 SBC-2 HB-85
MS-5024,-5024UD N/A A B,D 1 4.7K OHM SLR-24V HD-3 SBC-2R HB-85
MS-5210UD CAC-10E A B,D 10 4.7K OHM SLR-835BH-2 HD-6 N/A N/A
MS-5210UD CAC-10E A B,D 10 4.7K OHM SLR-835H HD-5 HSC-220R HB-72
MS-5210UD CAC-10E A B,D 10 4.7K OHM SLR-835H HD-5 NS4-220,NS6-220 HB-3
MS-5210UD N/A A B, D 15 4.7K OHM DCD-135, -190 HD-3 HSC-220L HB-64
MS-5210UD N/A A B, D 15 4.7K OHM DCD-135, -190 HD-3 HSC-220R HB-72
MS-5210UD N/A A B, D 15 4.7K OHM DCD-135, -190 HD-3 NS4-220, NS6-220 HB-3
MS-5210UD N/A A B, D 15 4.7K OHM DFE-135, -190 HD-3 HSC-220L HB-64
MS-5210UD N/A A B, D 15 4.7K OHM SIJ-24 HD-3 HSC-220R HB-72
MS-5210UD N/A A B, D 15 4.7K OHM SIJ-24 HD-3 NS4-220, NS6-220 HB-3
Page 1 of 2
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989
UPDATED 9/11/03
Page 2 of 2
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989
FIRESCAN
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
SHP 10-2171 MDL NO B/D 25 4.3K SIH-24F HD-3 HS-221D HB-4
SHP 10-2171 MDL NO B/D 25 4.3K SIH-24F HD-3 HSB-220 HB-56
SHP 10-2171 MDL NO B/D 25 4.3K SIH-24F HD-3 HSB-224 HB-53
SHP 10-2171 MDL NO B/D 25 4.3K SIH-24F HD-3 YBA-220 HB-3
SHP 10-2171 MDL NO B/D 25 4.3K SIH-24F HD-3 YBA-M224 HB-5
SHP 10-2171 MDL NO B/D 25 4.3K SLK-24F HD-3 HS-221D HB-4
SHP 10-2171 MDL NO B/D 25 4.3K SLK-24F HD-3 HSB-220 HB-56
SHP 10-2171 MDL NO B/D 25 4.3K SLK-24F HD-3 HSB-224 HB-53
SHP 10-2171 MDL NO B/D 25 4.3K SLK-24F HD-3 YBA-M220 HB-3
SHP 10-2171 MDL NO B/D 25 4.3K SLK-24F HD-3 YBA-M224 HB-5
SHP 10-2171 MDL NO B/D 25 4.3K SLK-24FH HD-3 HS-221D HB-4
SHP 10-2171 MDL NO B/D 25 4.3K SLK-24FH HD-3 HSB-220 HB-56
SHP 10-2171 MDL NO B/D 25 4.3K SLK-24FH HD-3 HSB-224 HB-53
SHP 10-2171 MDL NO B/D 25 4.3K SLK-24FH HD-3 YBA-M220 HB-3
SHP 10-2171 MDL NO B/D 25 4.3K SLK-24FH HD-3 YBA-M224 HB-5
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989
Page 1 of 3
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989
Page 2 of 3
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989
Page 3 of 3
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989
GRINNELL
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
C200 NA 24F B 30 7628 SIH-24F HD-3 HS-224D/HSB-224 HB-5
C200 NA 24F B 30 7628 SLK-24F,-FH HD3 HS-224D HB-5
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989
UPDATED 9/11/03
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989
ISI WIRELESS
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
FMS 1000 4ZID 4ZID D 66 N/A SIF-24F HD-2 HS-220 HB-3
FMS 1000 4ZID 4ZID D 66 N/A SLK-24FH HD-3 HS-220 HB-3
FMS 1000 4ZM 4ZMB B 66 4.7K OHM SIF-24F HD-2 HS-220 HB-3
FMS 1000 4ZM 4ZMA B 15 22K OHM SIF-24F HD-2 HS-220 HB-3
FMS 1000 4ZM 4ZMB B 66 4.7K OHM SLK-24FH HD-3 HS-220 HB-3
FMS 1000 4ZM 4ZMA B 15 22K OHM SLK-24FH HD-3 HS-220 HB-3
FMS 500 4ZID 4ZID D 66 N/A SIF-24F HD-2 HS-220 HB-3
FMS 500 4ZID 4ZID D 66 N/A SLK-24FH HD-3 HS-220 HB-3
FMS 500 4ZM 4ZMA B 15 22K OHM SIF-24F HD-2 HS-220 HB-3
FMS 500 4ZM 4ZMB B 66 4.7K OHM SIF-24F HD-2 HS-220 HB-3
FMS 500 4ZM 4ZMA B 15 22K OHM SLK-24FH HD-3 HS-220 HB-3
FMS 500 4ZM 4ZMB B 66 4.7K OHM SLK-24FH HD-3 HS-220 HB-3
FMS 500-96 4ZID 4ZID D 66 N/A SIF-24F HD-2 HS-220 HB-3
FMS 500-96 4ZID 4ZID D 66 N/A SLK-24FH HD-3 HS-220 HB-3
FMS 500-96 4ZM 4ZMA B 15 22K OHM SIF-24F HD-2 HS-220 HB-3
FMS 500-96 4ZM 4ZMB B 66 4.7K OHM SIF-24F HD-2 HS-220 HB-3
FMS 500-96 4ZM 4ZMA B 15 22K OHM SLK-24FH HD-3 HS-220 HB-3
FMS 500-96 4ZM 4ZMB B 66 4.7K OHM SLK-24FH HD-3 HS-220 HB-3
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989
MIRCOM
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
FA-1000 N/A A B, D 30 3.9K OHM DEF-135, -190 N/A HSC-220L HB-64
FA-1000 N/A A B, D 30 3.9K OHM SLR-24H HD-3 HSC-220R HB-72
FA-1000 N/A A B, D 30 3.9K OHM SLR-24H HD-3 NS4-220, NS6-220 HB-3
FA-101U N/A A B 30 3.9K OHM DCD-135 HD-3 HSC-220R HB-72
FA-101U N/A A B 30 3.9K OHM DCD-135 HD-3 NS4-220, NS6-220 HB-3
FA-101U N/A A B 30 3.9K OHM DCD-190 HD-3 HSC-220R HB-72
FA-101U N/A A B 30 3.9K OHM DCD-190 HD-3 NS4-220, NS6-220 HB-3
FA-101U N/A A B 30 3.9K OHM SIJ-24 HD-3 HSC-220R HB-72
FA-101U N/A A B 30 3.9K OHM SIJ-24 HD-3 NS4-220, NS6-220 HB-3
FA-101U N/A A B 30 3.9K OHM SLR-24 HD-3 HSC-220R HB-72
FA-101U N/A A B 30 3.9K OHM SLR-24 HD-3 NS4-220, NS6-220 HB-3
FA-101U, FA-1020U N/A A B, D 30 3.9K OHM DEF-135, -190 N/A HSC-220L HB-64
FA-101U, FA-1020U N/A A B, D 30 3.9K OHM SLR-24H HD-3 HSC-220R HB-72
FA-101U, FA-1020U N/A A B, D 30 3.9K OHM SLR-24H HD-3 NS4-220, NS6-220 HB-3
FA-1025U N/A A B 30 3.9K OHM DCD-135 HD-3 HSC-220R HB-72
FA-1025U N/A A B 30 3.9K OHM DCD-135 HD-3 NS4-220, NS6-220 HB-3
FA-1025U N/A A B 30 3.9K OHM DCD-190 HD-3 HSC-220R HB-72
FA-1025U N/A A B 30 3.9K OHM DCD-190 HD-3 NS4-220, NS6-220 HB-3
FA-1025U N/A A B 30 3.9K OHM DFE-135, -190 N/A HSC-220L HB-64
FA-1025U N/A A B 30 3.9K OHM SIJ-24 HD-3 HSC-220R HB-72
FA-1025U N/A A B,D 30 3.9K OHM SIJ-24 HD-3 NS4-220, NS6-220 HB-3
FA-1025U N/A A B 30 3.9K OHM SLR-24 HD-3 HSC-220R HB-72
FA-1025U N/A A B 30 3.9K OHM SLR-24 HD-3 NS4-220, NS6-220 HB-3
FA-1025U N/A A B,D 30 3.9K OHM SLR-24H HD-3 HSC-220R HB-72
FA-102U N/A A B 30 3.9K OHM SLR-24H HD-3 NS4-220, NS6-220 HB-3
FA-102U N/A A B 30 3.9K OHM DCD-135 HD-3 HSC-220R HB-72
FA-102U N/A A B 30 3.9K OHM DCD-135 HD-3 NS4-220, NS6-220 HB-3
FA-102U N/A A B 30 3.9K OHM DCD-190 HD-3 HSC-220R HB-72
FA-102U N/A A B 30 3.9K OHM DCD-190 HD-3 NS4-220, NS6-220 HB-3
FA-102U N/A A B 30 3.9K OHM SIJ-24 HD-3 HSC-220R HB-72
FA-102U N/A A B 30 3.9K OHM SIJ-24 HD-3 NS4-220, NS6-220 HB-3
FA-102U N/A A B 30 3.9K OHM SLR-24 HD-3 HSC-220R HB-72
FA-102U N/A A B 30 3.9K OHM SLR-24 HD-3 NS4-220, NS6-220 HB-3
FA-104/8U N/A A B, D 30 3.9K OHM DEF-135, -190 N/A HSC-220L HB-64
FA-104/8U N/A A B, D 30 3.9K OHM SLR-24H HD-3 HSC-220R HB-72
FA-104/8U N/A A B, D 30 3.9K OHM SLR-24H HD-3 NS4-220, NS6-220 HB-3
FA-104/8U, 8UX N/A A B 30 3.9K OHM SLR-24H HD-3 HSC-220R HB-72
FA-104/8U, 8UX N/A A B 30 3.9K OHM SLR-24H HD-3 NS4-220, NS6-220 HB-3
FA-104/8U, 8UX N/A A B 30 3.9K OHM DCD-135 HD-3 HSC-220R HB-72
FA-104/8U, 8UX N/A A B 30 3.9K OHM DCD-135 HD-3 NS4-220, NS6-220 HB-3
FA-104/8U, 8UX N/A A B 30 3.9K OHM DCD-190 HD-3 HSC-220R HB-72
FA-104/8U, 8UX N/A A B 30 3.9K OHM DCD-190 HD-3 NS4-220, NS6-220 HB-3
FA-104/8U, 8UX N/A A B 30 3.9K OHM SIJ-24 HD-3 HSC-220R HB-72
FA-104/8U, 8UX N/A A B 30 3.9K OHM SIJ-24 HD-3 NS4-220, NS6-220 HB-3
FA-104/8U, 8UX N/A A B 30 3.9K OHM SLR-24 HD-3 HSC-220R HB-72
FA-104/8U, 8UX N/A A B 30 3.9K OHM SLR-24 HD-3 NS4-220, NS6-220 HB-3
FA-104/BUX N/A A B, D 30 3.9K OHM DEF-135, -190 N/A HSC-220L HB-64
FA-104/BUX N/A A B, D 30 3.9K OHM SLR-24H HD-3 HSC-220R HB-72
FA-104/BUX N/A A B, D 30 3.9K OHM SLR-24H HD-3 NS4-220, NS6-220 HB-3
FA-200 N/A A B, D 30 3.9K OHM DEF-135, -190 N/A HSC-220L HB-64
FA-200 N/A A B, D 30 3.9K OHM SLR-24H HD-3 HSC-220R HB-72
FA-200 N/A A B, D 30 3.9K OHM SLR-24H HD-3 NS4-220, NS6-220 HB-3
FA-200 N/A A B, D 30 3.9K OHM SLR-835B-2 HD-6 N/A N/A
FA-200, FA-1000 N/A A B, D 30 3.9K OHM DCD-135 HD-3 HSC-220R HB-72
FA-200, FA-1000 N/A A B, D 30 3.9K OHM DCD-135 HD-3 NS4-220, NS6-220 HB-3
FA-200, FA-1000 N/A A B, D 30 3.9K OHM DCD-190 HD-3 HSC-220R HB-72
FA-200, FA-1000 N/A A B, D 30 3.9K OHM DCD-190 HD-3 NS4-220, NS6-220 HB-3
FA-200, FA-1000 N/A A B, D 30 3.9K OHM SIJ-24 HD-3 HSC-220R HB-72
FA-200, FA-1000 N/A A B, D 30 3.9K OHM SIJ-24 HD-3 NS4-220, NS6-220 HB-3
FA-200, FA-1000 N/A A B, D 30 3.9K OHM SLR-24 HD-3 HSC-220R HB-72
FA-200, FA-1000 N/A A B, D 30 3.9K OHM SLR-24 HD-3 NS4-220, NS6-220 HB-3
FA-1000 N/A A B, D 30 3.9K OHM SLR-835B-2 HD-6 N/A N/A
SERIES 100 N/A A B 30 3.9K OHM DCD-135 HD-3 HSC-220R HB-72
SERIES 100 N/A A B 30 3.9K OHM DCD-135 HD-3 NS4-220, NS6-220 HB-3
SERIES 100 N/A A B 30 3.9K OHM DCD-190 HD-3 HSC-220R HB-72
SERIES 100 N/A A B 30 3.9K OHM DCD-190 HD-3 NS4-220, NS6-220 HB-3
SERIES 100 N/A A B, D 30 3.9K OHM DEF-135, -190 N/A HSC-220L HB-64
SERIES 100 N/A A B 30 3.9K OHM SIJ-24 HD-3 HSC-220R HB-72
SERIES 100 N/A A B 30 3.9K OHM SIJ-24 HD-3 NS4-220, NS6-220 HB-3
SERIES 100 N/A A B 30 3.9K OHM SLR-24 HD-3 HSC-220R HB-72
SERIES 100 N/A A B 30 3.9K OHM SLR-24 HD-3 NS4-220, NS6-220 HB-3
SERIES 100 N/A A B, D 30 3.9K OHM SLR-24H HD-3 HSC-220R HB-72
SERIES 100 N/A A B, D 30 3.9K OHM SLR-24H HD-3 NS4-220, NS6-220 HB-3
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989
MODULAR PROT.
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
RP-1002M N/A A B, D 30 4.7K SIH-24F HD-3 HS-2-RB HB-10
RP-1002M N/A A B, D 30 4.7K SIH-24F HD-3 HS-22D HB-3
RP-1002M N/A A B, D 30 4.7K SIH-24F HD-3 HSB-220 HB-56
RP-1002M N/A A B, D 30 4.7K SIH-24F HD-3 HSB-224 HB-53
RP-1002M N/A A B, D 30 4.7K SIH-24F HD-3 YBA-M22 HB-3
RP-1002M N/A A B, D 30 4.7K SLK-24F HD-3 HS-2-RB HB-10
RP-1002M N/A A B, D 30 4.7K SLK-24F HD-3 HS-22D HB-3
RP-1002M N/A A B, D 30 4.7K SLK-24F HD-3 HSB-220 HB-56
RP-1002M N/A A B, D 30 4.7K SLK-24F HD-3 HSB-224 HB-53
RP-1002M N/A A B, D 30 4.7K SLK-24F HD-3 YBA-M22 HB-3
RP-1002M N/A A B, D 30 4.7K SLK-24FH HD-3 HS-2-RB HB-10
RP-1002M N/A A B, D 30 4.7K SLK-24FH HD-3 HS-22D HB-3
RP-1002M N/A A B, D 30 4.7K SLK-24FH HD-3 HSB-220 HB-56
RP-1002M N/A A B, D 30 4.7K SLK-24FH HD-3 HSB-224 HB-53
RP-1002M A B, D 30 SLK-24FH HD-3 YBA-M22 HB-3
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989
NAPCO
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
GEM-3200,-P9600 NA GEM-PS B 10 2.2K OHM SLR-835BH-2 HD-6 N/A N/A
GEM-P1632 NA MDL NO B 10 2.2K SLR-835B-2 HD-6 N/A N/A
GEM-P1632 NA NA B,D 10 2.2K OHM SLR-835BH-2 HD-6 N/A N/A
GEM-P3200 NA GEM-PF B 10 2.2K SLR-835B-2 HD-6 N/A N/A
GEM-P800 NA XP-S B 10 2.2K SLR-835B-2 HD-6 N/A N/A
GEM-P800,-P800E NA XP-S B 10 2.2K OHM SLR-835BH-2 HD-6 N/A N/A
GEM-P800E,P801 NA XP-S B 10 3.9K OHM SLR-835B-2 HD-6 N/A N/A
GEM-P801 NA XP-S B 10 2.2K OHM SLR-835BH-2 HD-6 N/A N/A
GEM-P816, V2,V3 GEM-P816 MDL NO B 10 2.2K OHM SLR-835BH-2 HD-6 N/A N/A
GEM-P816, V2,V3 NA XP-S B 10 2.2K OHM SLR-835B-2 HD-6 N/A N/A
GEM-P9600 NA GEM-PS B 10 2.2K SLR-835B-2 HD-6 N/A N/A
MA3000,SS5500 NA MDL NO B 10 2.2K SLR-835B-2 HD-6 N/A N/A
MA3000/SS5500 NA MDL NO B 10 2.2K OHM SLR-835BH-2 HD-6 N/A N/A
SS-P3200 NA GEM-PS B 10 2.2K OHM SLR-835BH-2 HD-6 N/A N/A
SS-P3200,-P9600 NA GEM-PS B 10 2.2K SLR-835B-2 HD-6 N/A N/A
SS-P9600 NA GEM-PS B 10 2.2K OHM SLR-835BH-2 HD-6 N/A N/A
XP-400, XP-600 NA XP-S B 10 2.2K SLR-835B-2 HD-6 N/A N/A
XP400, XP600 NA XP-S B 10 2.2K OHM SLR-835BH-2 HD-6 N/A N/A
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989
NOTIFIER
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
AFM-200 MMX-2, M3-TW A BD 1 3.9K SIH-24F HD-3 HS-2-RB HB-10
AFM-200 MMX-2, M3-TW A BD 25 3.9K SIH-24F HD-3 HS-22D HB-3
AFM-200 MMX-2, M3-TW A BD 25 3.9K SIH-24F HD-3 YBA-M22 HB-3
AFM-200 MMX-2, M3-TW A BD 1 3.9K SLK-24F HD-3 HS-2-RB HB-10
AFM-200 MMX-2, M3-TW A BD 25 3.9K SLK-24F HD-3 HS-22D HB-3
AFM-200 MMX-2, M3-TW A BD 1 3.9K SLK-24FH HD-3 HS-2-RB HB-10
AFM-200 MMX-2, M3-TW A BD 25 3.9K SLK-24FH HD-3 YBA-M22 HB-3
AFP-1010 MMX-2, M3-TW A BD 1 3.9K SIH-24F HD-3 HS-2-RB HB-10
AFP-1010 MMX-2, M3-TW A BD 1 3.9K SIH-24F HD-3 HS-2-RB HB-10
AFP-1010 MMX-2, M3-TW A BD 25 3.9K SIH-24F HD-3 HS-22D HB-3
AFP-1010 MMX-2, M3-TW A BD 25 3.9K SIH-24F HD-3 YBA-M22 HB-3
AFP-1010 MMX-2, M3-TW A BD 1 3.9K SLK-24F HD-3 HS-2-RB HB-10
AFP-1010 MMX-2, M3-TW A BD 25 3.9K SLK-24F HD-3 HS-22D HB-3
AFP-1010 MMX-2, M3-TW A BD 1 3.9K SLK-24FH HD-3 HS-2-RB HB-10
AFP-1010 MMX-2, M3-TW A BD 25 3.9K SLK-24FH HD-3 YBA-M22 HB-3
AFP-200 MMX-2, M3-TW A BD 1 3.9K SIH-24F HD-3 HS-2-RB HB-10
AFP-200 MMX-2, M3-TW A BD 25 3.9K SIH-24F HD-3 HS-22D HB-3
AFP-200 MMX-2, M3-TW A BD 25 3.9K SIH-24F HD-3 YBA-M22 HB-3
AFP-200 MMX-2, M3-TW A BD 1 3.9K SLK-24F HD-3 HS-2-RB HB-10
AFP-200 MMX-2, M3-TW A BD 25 3.9K SLK-24F HD-3 HS-22D HB-3
AFP-200 MMX-2, M3-TW A BD 1 3.9K SLK-24FH HD-3 HS-2-RB HB-10
AFP-200 MMX-2, M3-TW A BD 25 3.9K SLK-24FH HD-3 YBA-M22 HB-3
AM 2020 MMX-2, M3-TW A BD 1 3.9K SIH-24F HD-3 HS-2-RB HB-10
AM 2020 MMX-2, M3-TW A BD 25 3.9K SIH-24F HD-3 HS-22D HB-3
AM 2020 MMX-2, M3-TW A BD 25 3.9K SIH-24F HD-3 YBA-M22 HB-3
AM 2020 MMX-2, M3-TW A BD 1 3.9K SLK-24F HD-3 HS-2-RB HB-10
AM 2020 MMX-2, M3-TW A BD 25 3.9K SLK-24F HD-3 HS-22D HB-3
AM 2020 MMX-2, M3-TW A BD 1 3.9K SLK-24FH HD-3 HS-2-RB HB-10
AM 2020 MMX-2, M3-TW A BD 25 3.9K SLK-24FH HD-3 YBA-M22 HB-3
MMX-2 MMX-2 A BD 25 3.9K SIH-24F HD-3 HS-220 HB-56
MMX-2 MMX-2 A BD 25 3.9K SLK-24F/FH HD-3 HS-220 HB-56
RP-1001 N/A A BD 30 4.7K SIH-24F HD-3 HS-220 HB-56
RP-1001 N/A A BD 30 4.7K SIH-24F HD-3 HSB-224 HB-53
RP-1001 N/A A BD 30 4.7K SLK-24F/FH HD-3 HS-220 HB-56
RP-1001 N/A A BD 30 4.7K SLK-24F/FH HD-3 HS-220 HB-56
RP-1001 N/A A BD 30 4.7K SLK-24F/FH HD-3 HSB-224 HB-53
RP-1002 N/A A BD 30 4.7K SIH-24F HD-3 HS-220 HB-56
RP-1002 N/A A BD 30 4.7K SIH-24F HD-3 HSB-224 HB-53
RP-1002 N/A A BD 30 4.7K SLK-24F/FH HD-3 HS-220 HB-56
RP-1002 N/A A B, D 30 4.7K SLK-24F/FH HD-3 HSB-224 HB-53
S 5000 IZ-4,IZM-8 A B, D 15 4.7K OHM DFE-135,-190 N/A HSC-220L HB-64
S 5000 IZ-4,IZM-8 A B, D 15 4.7K OHM SLR-24H HD-3 HSC-220R HB-72
S 5000 IZ-4,IZM-8 A B, D 15 4.7K OHM SLR-24H HD-3 NS4-220, NS6-220 HB-3
S 5000 IZ-4,IZM-8 A B, D 20 4.7K OHM SLR-835B-2 HD-6 N/A N/A
S 5000 IZM-8 A B, D 10 4.7K OHM DCD-135,-190 HD-3 HSC-220R HB-72
S 5000 IZM-8 A B, D 10 4.7K OHM DCD-135,-190 HD-3 NS4-220, NS6-220 HB-3
S 5000 IZM-8 A B, D 10 4.7K OHM SIJ-24 HD-3 HSC-220R HB-72
S 5000 IZM-8 A B, D 10 4.7K OHM SIJ-24 HD-3 NS4-220, NS6-220 HB-3
S 5000 IZM-8 A B, D 10 4.7K OHM SLR-24 HD-3 HSC-220R HB-72
S 5000 IZM-8 A B, D 10 4.7K OHM SLR-24 HD-3 NS4-220, NS6-220 HB-3
S 5000 IZM-8, IZE-A A B 30 4.7K OHM SIF-24F HD-3 HS-22D HB-3
S 5000 IZM-8, IZE-A A D 30 N/A SIF-24F HD-3 HS-22D HB-3
S 5000 IZM-8, IZE-A A D 30 N/A SIF-24F HD-3 HS-220D HB-3
S 5000 IZM-8, IZE-A A B 30 4.7K OHM SIF-24F HD-3 HS-220D HB-3
S 5000 IZM-8, IZE-A A D 30 N/A SIF-24F HD-3 YBA-M22 HB-3
S 5000 IZM-8, IZE-A A B 30 4.7K OHM SIF-24F HD-3 YBA-M22 HB-3
S 5000 IZM-8, IZE-A A B 30 4.7K OHM SIF-24F HD-3 YBA-M220 HB-3
S 5000 IZM-8, IZE-A A D 30 N/A SIF-24F HD-3 YBA-M220 HB-3
S 5000 IZM-8, IZE-A A B 30 4.7K OHM SIH-24F HD-3 HS-22D HB-3
S 5000 IZM-8, IZE-A A D 30 N/A SIH-24F HD-3 HS-22D HB-3
S 5000 IZM-8, IZE-A A B 30 4.7K OHM SIH-24F HD-3 HS-220D HB-3
S 5000 IZM-8, IZE-A A D 30 N/A SIH-24F HD-3 HS-220D HB-3
S 5000 IZM-8, IZE-A A B 30 4.7K OHM SIH-24F HD-3 YBA-M22 HB-3
S 5000 IZM-8, IZE-A A D 30 N/A SIH-24F HD-3 YBA-M22 HB-3
S 5000 IZM-8, IZE-A A D 30 N/A SIH-24F HD-3 YBA-M220 HB-3
S 5000 IZM-8, IZE-A A B 30 4.7K OHM SIH-24F HD-3 YBA-M220 HB-3
S 5000 IZM-8, IZE-A A B 30 4.7K OHM SLK-24F HD-3 HS-22D HB-3
S 5000 IZM-8, IZE-A A D 30 N/A SLK-24F HD-3 HS-22D HB-3
Page 1 of 3
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989
Page 2 of 3
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989
Page 3 of 3
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989
PARADOX SECURITY SYSTEMS
POTTER ELECTRIC
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
PFC-100 NRC N/A A B, D 25 5.1K SLK-24FH HD3 HS-221D HB4
PFC 100 RC N/A A B, D 1 5.1K SIH-24F HD-3 HS-221D HB-2
PFC 100 RC N/A A B, D 1 5.1K SIH-24F HD-3 HS-221D HB-4
PFC 100 RC N/A A B, D 25 5.1K SLK-24F HD-3 HS-21D HB-2
PFC 100 RC N/A A B, D 25 5.1K SLK-24F HD-3 HS-221 RB HB-13
PFC 100 RC N/A A B, D 25 5.1K SLK-24F HD-3 HS-221D HB-4
PFC 100 RC N/A A B, D 25 5.1K SLK-24FH HD-3 HS-21D HB-2
PFC 100 RC N/A A B, D 25 5.1K SLK-24FH HD-3 HS-221 RB HB-13
PFC-100 RC N/A A B, D 25 5.1K SIH-24F HD-3 HSB-221 HB-54
PFC-100 RC N/A A B, D 25 5.1K SIH-24F HD-3 HSB-221N HB-54
PFC-100 RC N/A A B, D 25 5.1K SIH-24F HD-3 HSB-221R HB-71
PFC-100 RC N/A A B, D 25 5.1K SLK-24F HD-3 HSB-221 HB-54
PFC-100 RC N/A A B, D 25 5.1K SLK-24F HD-3 HSB-221N HB-54
PFC-100 RC N/A A B, D 25 5.1K SLK-24F HD-3 HSB-221R HB-71
PFC-100 RC N/A A B, D 25 5.1K SLK-24FH HD-3 HSB-221 HB-54
PFC-100 RC N/A A B, D 25 5.1K SLK-24FH HD-3 HSB-221N HB-54
PFC-100 RC N/A A B, D 25 5.1K SLK-24FH HD-3 HSC-221R HB-71
PFC-2000 RC N/A A B, D 25 5.1K SIH-24F HD-3 HSB-221 HB-54
PFC-2000 RC N/A A B, D 25 5.1K SIH-24F HD-3 HSB-221N HB-54
PFC-2000 RC N/A A B, D 25 5.1K SIH-24F HD-3 HSC-221R HB-71
PFC-2000 RC N/A A B, D 25 5.1K SLK-24F HD-3 HSB-221 HB-54
PFC-2000 RC N/A A B, D 25 5.1K SLK-24F HD-3 HSB-221N HB-54
PFC-2000 RC N/A A B, D 25 5.1K SLK-24F HD-3 HSC-221R HB-71
PFC-2000 RC N/A A B, D 25 5.1K SLK-24FH HD-3 HSB-221 HB-54
PFC-2000 RC N/A A B, D 25 5.1K SLK-24FH HD-3 HSB-221N HB-54
PFC-2000 RC N/A A B, D 25 5.1K SLK-24FH HD-3 HSC-221R HB-71
PFC-4410 N/A A B, D 25 5.1K SIH-24F HD-3 HSB-221 HB-54
PFC-4410 N/A A B, D 25 5.1K SIH-24F HD-3 HSB-221N HB-54
PFC-4410 N/A A B, D 25 5.1K SLK-24F HD-3 HSB-221 HB-54
PFC-4410 N/A A B, D 25 5.1K SLK-24F HD-3 HSB-221N HB-54
PFC-4410 N/A A B, D 25 5.1K SLK-24FH HD-3 HSB-221 HB-54
PFC-4410 N/A A B, D 25 5.1K SLK-24FH HD-3 HSB-221N HB-54
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989
PROTECTOWIRE
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
ACR-1600 SERIES ZM-2200 MDL NO AD 20 ELR-1A SIF-24F HD-3 HS-220D HB-3
ACR-1600 SERIES ZM-2200 MDL NO AD 20 ELR-1A SIF-24F HD-3 HS-220D HB-3
ACR-1600 SERIES ZM-2200 MDL NO AD 20 ELR-1A SLK-24F HD-3 HS-220D HB-3
ACR-1600 SERIES ZM-2200 MDL NO AD 20 ELR-1A SLK-24F HD-3 HS-220D HB-3
ACR-1600 SERIES ZM-2200 MDL NO AD 20 ELR-1A SLK-24FH HD-3 HS-220D HB-3
ACR-1600 SERIES ZM-2200 MDL NO AD 20 ELR-1A SLK-24FH HD-3 HS-220D HB-3
FS2000 ZC-91, ZC-91M MDL NO B, D 30 4.7K OHM DCD-135 HD-3 HSC-220R HB-72
FS2000 ZC-91, ZC-91M MDL NO B, D 30 4.7K OHM DCD-135 HD-3 NS4-220, NS6-220 HB-3
FS2000 ZC-91, ZC-91M MDL NO B, D 30 4.7K OHM DCD-190 HD-3 HSC-220R HB-72
FS2000 ZC-91, ZC-91M MDL NO B, D 30 4.7K OHM DCD-190 HD-3 NS4-220, NS6-220 HB-3
FS2000 ZC-91, ZC-91M MDL NO B, D 30 4.7K OHM DFE-135,-190 N/A HSC-220L HB-64
FS2000 ZC-91, ZC-91M MDL NO B, D 30 4.7K OHM SIJ-24 HD-3 HSC-220R HB-72
FS2000 ZC-91, ZC-91M MDL NO B, D 30 4.7K OHM SIJ-24 HD-3 NS4-220, NS6-220 HB-3
FS2000 ZC-91, ZC-91M MDL NO B, D 30 4.7K OHM SLR-24 HD-3 HSC-220R HB-72
FS2000 ZC-91, ZC-91M MDL NO B, D 30 4.7K OHM SLR-24 HD-3 NS4-220, NS6-220 HB-3
FS2000 ZC-91, ZC-91M MDL NO B, D 30 4.7K OHM SLR-24H HD-3 HSC-220R HB-72
FS2000 ZC-91, ZC-91M MDL NO B, D 30 4.7K SLR-24H HD-3 NS4-220 HB-3
FS2000 ZC-91, ZC-91M MDL NO B, D 30 4.7K OHM SLR-24H HD-3 NS4-220, NS6-220 HB-3
FS2000 ZC-91, ZC-91M MDL NO B, D 30 4.7K OHM SLR-835B-2 HD-6 N/A N/A
FS2000 SERIES ZC-91 ZC-91 BD 30 4.7K OHM SIH-24F HD-S HS-220D HB-3
FS2000 SERIES ZC-91 ZC-91 BD 30 4.7K OHM SIH-24F HD-S HS-220D HB-3
FS2000 SERIES ZC-91 ZC-91 BD 30 4.7K OHM SLK-24F HD-3 HS-220D HB-3
FS2000 SERIES ZC-91M ZC-91 BD 30 4.7K OHM SLK-24F HD-3 HS-220D HB-3
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989
RADIONICS
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
D2012,D2112 2 WIRE POINT1 A 40 1.8K OHM SLR-835B-2 HD-6 N/A N/A
D2212 ZONE 1 221201 A 15 2K D262 HD-4 D261A HB-80
D2212, D2412 2 WIRE POINT1 A 40 1.8K OHM SLR-835B-2 HD-6 N/A N/A
D2212B 1 B A 15 15- D262 HD-4 D261A HB-80
D2212B ZONE 1 221201 A 15 2K D262 HD-4 D261A HB-80
D2212BE 1 B A 15 15- D262 HD-4 D261A HB-80
D2412UE 1 B A 15 15- D262 HD-4 D261A HB-80
D2812 1 B A 15 15 D262 HD-4 D261A HB-80
D2812,D2812U 2 WIRE POINT1 A 40 1.8K OHM SLR-835B-2 HD-6 N/A N/A
D4112 N/A B A 20 1.8K OHM SLK-12 HD-4 HSB-12-1 HB-80
D4112 N/A B A 20 1.8K OHM SLK-12 HD-4 HSB-12-1N HB-80
D4112 N/A 1 A 20 D104F SLK-12 HD-4 YBC-RL/12 HB-40
D6112 N/A B A 20 1.8K OHM SLK-12 HD-4 HSB-12-1 HB-80
D6112 N/A B A 20 1.8K OHM SLK-12 HD-4 HSB-12-1N HB-80
D6112 N/A 2 A 20 D104F SLK-12 HD-4 YBC-RL/12 HB-40
D7112 D125B A A 20 1.8K OHM SLK-12 HD-4 HSB-12-1 HB-80
D7112 D125B A A 20 1.8K OHM SLK-12 HD-4 HSB-12-1N HB-80
D7212 D125B A A 20 1.8K OHM SLK-12 HD-4 HSB-12-1 HB-80
D7212 D125B A A 20 1.8K OHM SLK-12 HD-4 HSB-12-1N HB-80
D7212 OWB/125B 24VDC MDL NO A 80 1.8K SIH-24F HD-3 HS224D HB-5
D7212 OWB/D125B 24VDC MDL NO A 80 1.8K SIH-24F HD-3 HS224D HB-5
D7212 OWB/D125B 24VDC MDL NO A 80 1.8K SLK-24F HD-3 HS224D HB-5
D7212,D7412 D125B D125B A 40 1.8K OHM DFE-135,-190 N/A HSC-220L HB-64
D7212,D7412 D125B D125B A 40 1.8K OHM SLR-24H HD-3 HSC-220R HB-72
D7212,D7412 D125B D125B A 40 1.8K OHM SLR-24H HD-3 NS4-100, NS6-100 HB-55
D7212,D7412 D125B D125B A 40 1.8K OHM SLR-24H HD-3 NS4-220, NS6-220 HB-3
D7212,D7412 D125B D125B A 40 1.8K OHM SLR-24H HD-3 NS4-224, NS6-224 HB-5
D7212,D7412 D125B D125B A 40 1.8K OHM SLR-835B-2 HD-6 N/A N/A
D7212,D7412 ZONE 1 D125B A 40 1.8K OHM DCD-135,DCD-190 HD-3 HSC-220R HB-72
D7212,D7412 ZONE 1 D125B A 40 1.8K OHM DCD-135,DCD-190 HD-3 NS4-220, NS6-220 HB-3
D7212,D7412 ZONE 1 D125B A 40 1.8K OHM SIJ-24,SLR-24 HD-3 HSC-220R HB-72
D7212,D7412 ZONE 1 D125B A 40 1.8K OHM SIJ-24,SLR-24 HD-3 NS4-220, NS6-220 HB-3
D7412 ONBOARD W/125B MDL NO A 80 1.8K SIH-24F HD-3 HS224D HB-5
D7412 ONBOARD W/D125B MDL NO A 80 1.8K SIH-24F HD-3 HS224D HB-5
D7412 ONBOARD W/D125B MDL NO A 15 1.8K SLK-12 HD-4 YBC-AL/12 HB-40
D7412 ONBOARD W/D125B MDL NO A 80 1.8K SLK-24F HD-3 HS224D HB-5
D8112 D8112 W/D125B MDL NO A 20 1.8K OHM SLK-12 HD-4 HSB-12-1 HB-80
D8112 D8112 W/D125B MDL NO A 20 1.8K OHM SLK-12 HD-4 HSB-12-1N HB-80
D8112 N/A 2 TO 8 A 20 D108 SLK-12 HD-4 YBC-RL/12 HB-40
D8112,D9112 ZONE NO D125B A 40 1.8K OHM SLR-835B--2 HD-6 N/A N/A
D9112 D125B A A 20 1.8K OHM SLK-12 HD-4 HSB-12-1 HB-80
D9112 D125B A A 20 1.8K OHM SLK-12 HD-4 HSB-12-1N HB-80
D9112,D9412 ZONE 1 D125B A 40 1.8K OHM DCD-135,DCD-190 HD-3 HSC-220R HB-72
D9112,D9412 ZONE 1 D125B A 40 1.8K OHM DCD-135,DCD-190 HD-3 NS4-220, NS6-220 HB-3
D9112,D9412 ZONE 1 D125B A 40 1.8K OHM SIJ-24,SLR-24 HD-3 HSC-220R HB-72
D9112,D9412 ZONE 1 D125B A 40 1.8K OHM SIJ-24,SLR-24 HD-3 NS4-220, NS6-220 HB-3
D9112B,D9124 D125B D125B A 40 1.8K OHM DFE-135,-190 N/A HSC-220L HB-64
D9112B,D9124 D125B D125B A 40 1.8K OHM SLR-24H HD-3 HSC-220R HB-72
D9112B,D9124 D125B D125B A 40 1.8K OHM SLR-24H HD-3 NS4-100, NS6-100 HB-55
D9112B,D9124 D125B D125B A 40 1.8K OHM SLR-24H HD-3 NS4-220, NS6-220 HB-3
D9112B,D9124 D125B D125B A 40 1.8K OHM SLR-24H HD-3 NS4-224, NS6-224 HB-5
D9112B,D9124 D125B D125B A 40 1.8K OHM SLR-835B--2 HD-6 N/A N/A
D9412 D125B D125B A 40 1.8K OHM DFE-135,-190 N/A HSC-220L HB-64
D9412 D125B D125B A 40 1.8K OHM SLR-24H HD-3 HSC-220R HB-72
D9412 D125B D125B A 40 1.8K OHM SLR-24H HD-3 NS4-100, NS6-100 HB-55
D9412 D125B D125B A 40 1.8K OHM SLR-24H HD-3 NS4-220, NS6-220 HB-3
D9412 D125B D125B A 40 1.8K OHM SLR-24H HD-3 NS4-224, NS6-224 HB-5
D9412 D125B D125B A 40 1.8K OHM SLR-835B--2 HD-6 N/A N/A
D9412 ONBOARD W/D125B MDL NO A 80 1.8K SIH-24F HD-3 HS224D HB-5
D9412 ONBOARD W/D125B MDL NO A 15 1.8K SLK-12 HD-4 YBC-AL/12 HB-40
D9412 ONBOARD W/D125B MDL NO A 80 1.8K SLK-24F HD-3 HS224D HB-5
D9412 ONBOARD W/D125B MDL NO A 80 1.8K SLK-24F HD-3 HS224D HB-5
1 of 1
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989
RAULAND-BORG
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
FA3002 FA3002 LP01 A 50 3.3K SIH-24F HD-3 HS-220D HB-3
FA3002 FA3002 LP02 A 50 3.3K SIH-24F HD-3 HS-220D HB-3
FA3002 FA3002 LP01 A 50 3.3K SIH-24F HD-3 HSB-220 HB-56
FA3002 FA3002 LP02 A 50 3.3K SIH-24F HD-3 HSB-220 HB-56
FA3002 FA3002 LP01 A 50 3.3K SIH-24F HD-3 HSC-220R HB-72
FA3002 FA3002 LP02 A 50 3.3K SIH-24F HD-3 HSC-220R HB-72
FA3002 FA3002 LP01 A 50 3.3K SLK-24F HD-3 HS-220D HB-3
FA3002 FA3002 LP02 A 50 3.3K SLK-24F HD-3 HS-220D HB-3
FA3002 FA3002 LP02 A 50 3.3K SLK-24F HD-3 HSB-220 HB-56
FA3002 FA3002 LP01 A 50 3.3K SLK-24F HD-3 HSB-220 HB-56
FA3002 FA3002 LP02 A 50 3.3K SLK-24F HD-3 HSC-220R HB-72
FA3002 FA3002 LP01 A 50 3.3K SLK-24F HD-3 HSC-220R HB-72
FA3002 FA3002 LP01 A 50 3.3K SLK-24FH HD-3 HS-220D HB-3
FA3002 FA3002 LP02 A 50 3.3K SLK-24FH HD-3 HS-220D HB-3
FA3002 FA3002 LP02 A 50 3.3K SLK-24FH HD-3 HSB-220 HB-56
FA3002 FA3002 LP01 A 50 3.3K SLK-24FH HD-3 HSC-220R HB-72
FA3002 FA3002 LP02 A 50 3.3K SLK-24FH HD-3 HSC-220R HB-72
FA3002 FA3120,FA3125 CZ02 A 1 30K SIH-24F HD-3 HS-220D HB-3
FA3002 FA3120,FA3125 CZ01 A 1 20K SIH-24F HD-3 HS-220D HB-3
FA3002 FA3120,FA3125 CZ02 A 1 30K SIH-24F HD-3 HS-220D HB-3
FA3002 FA3120,FA3125 CZ01 A 1 20K SIH-24F HD-3 HSB-220 HB-56
FA3002 FA3120,FA3125 CZ01 A 1 20K SLK-24F HD-3 HS-220D HB-3
FA3002 FA3120,FA3125 CZ01 A 1 20K SLK-24F HD-3 HS-220D HB-3
FA3002 FA3120,FA3125 CZ01 A 1 20K SLK-24F HD-3 HSB-220 HB-56
FA3002 FA3120,FA3125 CZ02 A 3 30K SLK-24F HD-3 HSB-220 HB-56
FA3002 FA3120,FA3125 CZ01 A 1 20K SLK-24FH HD-3 HS-220D HB-3
FA3002 FA3120,FA3125 CZ02 A 1 30K SLK-24FH HD-3 HS-220D HB-3
FA3002 FA3120,FA3125 CZ02 A 3 30K SLK-24FH HD-3 HSB-220 HB-56
FA3002 FA3120,FA3125 CZ01 A 1 20K SLK-24FH HD-3 HSB-220 HB-56
FA3002 FA3120,FA3125 CZ02 A 3 30K SIH-24F HD-3 HSB-220 HB-56
FA3002 FA3120,FAP3125 CZ02 A 1 30K SLK-24FH HD-3 HS-220D HB-3
FA3002 FA3130,FAP3135 CZ02 A 1 30K SIH-24F HD-3 HS-220D HB-3
FA3002 FA3130,FAP3135 CZ01 A 1 20K SIH-24F HD-3 HS-220D HB-3
FA3002 FA3130,FAP3135 CZ02 A 3 30K SIH-24F HD-3 HSB-220 HB-56
FA3002 FA3130,FAP3135 CZ01 A 1 20K SIH-24F HD-3 HSB-220 HB-56
FA3002 FA3130,FAP3135 CZ02 A 1 30K SLK-24F HD-3 HS-220D HB-3
FA3002 FA3130,FAP3135 CZ01 A 1 20K SLK-24F HD-3 HS-220D HB-3
FA3002 FA3130,FAP3135 CZ01 A 1 20K SLK-24F HD-3 HSB-220 HB-56
FA3002 FA3130,FAP3135 CZ02 A 3 30K SLK-24F HD-3 HSB-220 HB-56
FA3002 FA3130,FAP3135 CZ02 A 1 30K SLK-24FH HD-3 HS-220D HB-3
FA3002 FA3130,FAP3135 CZ02 A 3 30K SLK-24FH HD-3 HSB-220 HB-56
FA3002 FA3130,FAP3135 CZ01 A 1 20K SLK-24FH HD-3 HSB-220 HB-56
FIRE PLEX FA3001 LPO1 2 A 50 1344 SIH-24F HD-3 HS-220D HB-3
FIRE PLEX FA3001 LPO1 2 A 50 1344 SLK-24F HD-3 HS-220D HB-3
FIRE PLEX FA3130,FAP3135 CZ01 A 1 1346 SLK-24F HD-3 HS-220D HB-3
FIRE PLEX FA3130,FAP3135 CZ01 A 1 1346 SIH-24F HD-3 HS-220D HB-3
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989
SECURTON
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
MR-2600 MR-2600 MDL NO B 29 MRD-2904 SIH-24F HD-2 HS-221D HB-4
MR-2600 MR-2600 MDL NO B 29 MRD-2904 SIH-24F HD-2 YBA-M221 HB-4
MR-2600 MR-2600 MDL NO B 25 MRD-2904 SIH-24F HD-3 HS-221D HB-4
MR-2600 MR-2600 MDL NO B 25 MRD-2904 SIH-24F HD-3 YBA-M221 HB-4
MR-2600 MR-2600 MDL NO B 22 MRD-2904 SLK-24F HD-3 HS-221D HB-4
MR-2600 MR-2600 MDL NO B 22 MRD-2904 SLK-24F HD-3 YBA-M221 HB-4
MR-2600 MR-2600 MDL NO B 22 MRD-2904 SLK-24FH HD-3 HS-221D HB-4
MR-2600 MR-2600 MDL NO B 22 MRD-2904 SLK-24FH HD-3 YBA-M221 HB-4
MR-2900 MR-2928 A B, C 34 MRD-2904 SIH-24F HD-2 HS-221D HB-4
MR-2900 MR-2928 A B, C 34 MRD-2904 SIH-24F HD-2 YBA-M221 HB-4
MR-2900 MR-2928 A B, C 26 MRD-2904 SIH-24F HD-3 HS-221D HB-4
MR-2900 MR-2928 A B, C 26 MRD-2904 SIH-24F HD-3 YBA-M221 HB-4
MR-2900 MR-2928 A B, C 24 MRD-2904 SLK-24F HD-3 HS-221D HB-4
MR-2900 MR-2928 A B, C 24 MRD-2904 SLK-24F HD-3 HS-221D HB-4
MR-2900 MR-2928 A B, C 24 MRD-2904 SLK-24F HD-3 YBA-M221 HB-4
MR-2900 MR-2928 A B, C 24 MRD-2904 SLK-24FH HD-3 YBA-M221 HB-4
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989
SILENT KNIGHT
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
5204 N/A 24C B 30 7628 DFE-135,-190 N/A HSC-220L HB-64
5204 N/A 24C B 30 7628 SLR-24H HD-3 HSC-220R HB-72
5204 N/A 24C B 30 7628 SLR-24H HD-3 NS4-220, NS6-220 HB-3
5204 12 VOLT N/A N/A A 20 7628 SLK-24F HD-3 HS-224D HB-5
5204 12 VOLT N/A N/A A 20 7628 SLK-24FH HD-3 HS-224D HB-5
5207 5210 24A B 30 7628 DCD-135 HD-3 HSC-220R HB-72
5207 5210 24A B 30 7628 DCD-135 HD-3 NS4-220, NS6-220 HB-3
5207 5210 24A B 30 7628 DCD-190 HD-3 HSC-220R HB-72
5207 5210 24A B 30 7628 DCD-190 HD-3 NS4-220, NS6-220 HB-3
5207 5210 24A B 30 7628 DFE-135,-190 N/A HSC-220L HB-64
5207 5210 24A B 30 7628 SIJ-24 HD-3 HSC-220R HB-72
5207 5210 24A B 30 7628 SIJ-24 HD-3 NS4-220, NS6-220 HB-3
5207 5210 24A B 30 7628 SLR-24 HD-3 HSC-220R HB-72
5207 5210 24A B 30 7628 SLR-24 HD-3 NS4-220, NS6-220 HB-3
5207 5210 24A B 30 7628 SLR-24H HD-3 HSC-220R HB-72
5207 5210 24A B 30 7628 SLR-24H HD-3 NS4-220, NS6-220 HB-3
5207 5210 24A B 30 7628 SLR-835 HD-3 NS4-100, NS6-100 HB-55
5207 5210 24A B 30 7628 SLR-835 HD-3 NS4-220, NS6-220 HB-3
5207 5210 24A B 30 7628 SLR-835B-2 HD-6 N/A N/A
5207 5210 24A B 10 7628 SIH-24F HD-3 HS-224D/HSB-224 HB-5
5207 5210 24A B 10 7628 SLK-24F HD-3 HS-224D/HSB-224 HB-5
5207 N/A 24D B 30 7628 DCD-135 HD-3 HSC-220R HB-72
5207 N/A 24D B 30 7628 DCD-135 HD-3 NS4-220, NS6-220 HB-3
5207 N/A 24D B 30 7628 DCD-190 HD-3 HSC-220R HB-72
5207 N/A 24D B 30 7628 DCD-190 HD-3 NS4-220, NS6-220 HB-3
5207 N/A 24D B 30 7628 DFE-135,-190 N/A HSC-220L HB-64
5207 N/A 24D B 30 7628 SIJ-24 HD-3 HSC-220R HB-72
5207 N/A 24D B 30 7628 SIJ-24 HD-3 NS4-220, NS6-220 HB-3
5207 N/A 24B A 40 7628 4.7 SLK-24F HD-3 HS-224D HB-5
5207 N/A 24A B 20 7628 SLK-24F HD-3 HS-224D HB-5
5207 N/A 24B A 40 7628 4.7 SLK-24FH HD-5 HS-224C HB-5
5207 N/A 24B A 40 7628 4.7 SLK-24FH HD-5 HS-224C HB-5
5207 N/A 24A B 20 7628 SLK-24FH HD-3 HS-224D HB-5
5207 N/A 24D B 30 7628 SLR-24 HD-3 HSC-220R HB-72
5207 N/A 24D B 30 7628 SLR-24 HD-3 NS4-220, NS6-220 HB-3
5207 N/A 24D B 30 7628 SLR-24H HD-3 HSC-220R HB-72
5207 N/A 24D B 30 7628 SLR-24H HD-3 NS4-220, NS6-220 HB-3
5207 N/A 24D B 25 7628 SIH-24F HD-3 HS-224D/HSB-224 HB-5
5207 N/A 24D B 25 7628 SLK-24F HD-3 HS-224D/HSB-224 HB-5
5820, 5828XL N/A 24H B, D 12 7628 DCD-135,-190 HD-3 HSC-220L HB-64
5820, 5828XL N/A 24H B, D 12 7628 DCD-135,-190 HD-3 HSC-220R HB-72
5820, 5828XL N/A 24H B, D 12 7628 DCD-135,-190 HD-3 NS4-220, NS6-220 HB-3
5820, 5828XL N/A 24H B, D 12 7628 DFE-135,-190 N/A HSC-220L HB-64
5820, 5828XL N/A 24H B, D 12 7628 SIJ-24 HD-3 HSC-220R HB-72
5820, 5828XL N/A 24H B, D 12 7628 SIJ-24 HD-3 NS4-220, NS6-220 HB-3
5820, 5828XL N/A 24H B, D 12 7628 SLR-24H, -24V HD-3 HSC-220R HB-72
5820, 5828XL N/A 24H B, D 12 7628 SLR-24H, -24V HD-3 NS4-100, NS6-100 HB-55
5820, 5828XL N/A 24H B, D 12 7628 SLR-24H, -24V HD-3 NS4-220, NS6-220 HB-3
5820, 5828XL N/A 24H B, D 12 7628 SLR-835 HD-3 NS4-100, NS6-100 HB-55
5820, 5828XL N/A 24H B, D 12 7628 SLR-835 HD-3 NS4-220, NS6-220 HB-3
5820, 5828XL N/A 24H B, D 12 7628 SLR-835B-2 HD-6 N/A N/A
7181 N/A B B 30 7628 DCD-135 HD-3 HSC-220R HB-72
7181 N/A B B 30 7628 DCD-135 HD-3 NS4-220, NS6-220 HB-3
7181 N/A B B 30 7628 DCD-190 HD-3 HSC-220R HB-72
7181 N/A B B 30 7628 DCD-190 HD-3 NS4-220, NS6-220 HB-3
7181 N/A B B 30 7628 DFE-135,-190 N/A HSC-220L HB-64
7181 N/A B B 30 7628 SIJ-24 HD-3 HSC-220R HB-72
7181 N/A B B 30 7628 SIJ-24 HD-3 NS4-220, NS6-220 HB-3
7181 N/A B B 18 7628 SLK-12 HD-4 HSB-12-1 HB-80
7181 N/A B B 18 7628 SLK-12 HD-4 HSB-12-1 HB-80
7181 N/A B B 18 7628 SLK-12 HD-4 HSB-12-1N HB-80
7181 N/A B B 18 7628 SLK-12 HD-4 HSB-12-1N HB-80
7181 N/A B B 30 7628 SLR-24 HD-3 HSC-220R HB-72
7181 N/A B B 30 7628 SLR-24 HD-3 NS4-220, NS6-220 HB-3
7181 N/A B B 30 7628 SLR-24H HD-3 HSC-220R HB-72
7181 N/A B B 30 7628 SLR-24H HD-3 NS4-220, NS6-220 HB-3
7181 N/A 24B B, D 20 7628 SLR-835B-2 HD-6 N/A N/A
SD500-SDM NA 241 B/D 25 7628 SIH-24F HD-3 YBA-M224 HB-5
Page 1 of 3
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989
Page 2 of 3
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989
UPDATED 9/11/03
Page 3 of 3
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989
SIMPLEX
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
SERIES 4010 4090-9101&-9106 MDL NO B, D 20 3.3K SIH-24F HD-3 HS-221 HB-4
SERIES 4010 4090-9101&-9106 MDL NO B, D 20 3.3K SIH-24F HD-3 HSB-221S HB-54
SERIES 4010 4090-9101&-9106 MDL NO B, D 20 3.3K SLK-24FB HD-3 HS-221 HB-4
SERIES 4010 4090-9101&-9106 MDL NO B, D 20 3.3K SLK-24FH HD-3 HS-221 HB-4
SERIES 4010 4090-9101&-9106 MDL NO B, D 20 3.3K SLK-24FH HD-3 HSB-221S HB-54
SERIES 4010 4090-9101&-9106 MDL NO B, D 20 3.3K SLK-24KB HD-3 HS-221 HB-4
SERIES 4010 4090-9101&-9106 MDL NO B, D 20 3.3K SLK-24KB HD-3 HSB-221S HB-54
SERIES 4010 4090-9101&-9106 MDL NO B, D 20 40909101 SLK-24FB HD-3 HSB-221S HB-54
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
324 320/LC/OS-24 MDL NO B 15 15 K SIH-24F HD-2 HS-200 D HD-20
324 320/LC/OS-24 MDL NO B 11 15 K SIH-24F HD-3 HS-200 D HD-20
324 320/LC/OS-24 MDL NO B 13 15 K SLK-24F HD-3 HS-200 D HD-20
324 320/LC/OS-24 MDL NO B 13 15 K SLK-24FG HD-3 HS-200 D HD-20
624/641 MX8/WIB MDL NO B 13 15K SLK-24F HD-3 HS-200 D HD-20
624/MX ADS MDL NO B 15 15 K SIH-24F HD-2 HS-200 D HD-20
624/MX ADS MDL NO B 11 15 K SIH-24F HD-3 HS-200 D HD-20
624/MX ADS MDL NO B 13 15 K SLK-24F HD-3 HS-200 D HD-20
624/MX ADS MDL NO B 13 15 K SLK-24FH HD-3 HS-200 D HD-20
624/MX ADS-H MDL NO B 50 4.7K SIH-24F HD-2 HS-200 D HD-20
624/MX ADS-H MDL NO B 39 4.7K SIH-24F HD-3 HS-200 D HD-20
624/MX ADS-H MDL NO B 44 4.7K SLK-24F HD-3 HS-200 D HD-20
624/MX MX/OSH MDL NO B 50 4.7K SIF-24F HD-2 HS-200 D HD-20
624/MX MX/OSH MDL NO B 40 4.7K OHM SIF-24F HD-2 HS-22D HB-3
624/MX MX/OSH MDL NO B 39 4.7K SIH-24F HD-3 HS-200 D HD-20
624/MX MX/OSH MDL NO B 44 4.7K SLK-24F HD-3 HS-200 D HD-20
624/MX MX/OSH MDL NO B 40 4.7K OHM SLK-24F HD-3 HS-22D HB-3
624/MX MX/OSH MDL NO B 44 4.7K SLK-24FH HD-3 HS-200 D HD-20
624/MX MX/OSH MDL NO B 39 4.7K SLK-24FH HD-3 HS-200 D HD-20
624/MX MX/OSH MDL NO B 40 4.7K OHM SLK-24FH HD-3 HS-22D HB-3
624/MX MX/I0-1O MDL NO B, D 22 15 k SLK-24FH HD-3 HS-200 D HD-20
624/MX MX/I01O-H MDL NO B 39 4.7K SIH-24F HD-3 HS-200 D HD-20
624/MX MX/I01O MDL NO B 39 4.7K SIF-24F HD-2 HS-200 D HD-20
624/MX MX/I01O MDL NO B 50 4.7K SIF-24F HD-2 HS-200 D HD-20
624/MX MX/I01O MDL NO B, D 19 15 K SIH-24F HD-3 HS-200 D HD-20
624/MX MX/I01O MDL NO B, D 22 15 K SLK-24F HD-3 HS-200 D HD-20
624/MX MX/I01O-H MDL NO B 44 4.7K SLK-24F HD-3 HS-200 D HD-20
624/MX MX/I01O-H MDL NO B 44 4.7K SLK-24FH HD-3 HS-200 D HD-20
624/MX MX/I0-1O-H MDL NO B 50 4.7K OHM SIH-24F HD-2 HS-22D HB-3
624/MX MX/I0-1O-H MDL NO B 40 4.7K OHM SLK-24F HD-3 HS-22D HB-3
624/MX MX/I0-1O-H MDL NO B 40 4.7K OHM SLK-24FH HD-3 HS-22D HB-3
624/MX MX/OSRP MDL NO B 15 15 K SIF-24F HD-2 HS-200 D HD-20
624/MX MX/OSRP MDL NO B 11 15 K SIH-24F HD-3 HS-200 D HD-20
624/MX MX/OSRP MDL NO B 13 15 K SLK-24F HD-3 HS-200 D HD-20
624/MX MX/OSRP MDL NO B 13 15 K SLK-24FH HD-3 HS-200 D HD-20
640 MX8/WIBH MDL NO B 50 4.7K OHM SIF-24F HD-2 HS-22D HB-3
640 MX8/WIBH MDL NO B 40 4.7K OHM SLK-24F HD-3 HS-22D HB-3
640 MX8/WIBH MDL NO B 40 4.7K OHM SLK-24FH HD-3 HS-22D HB-3
640 S2W MDL NO B 50 4.7K OHM SIF-24F HD-2 HS-22D HB-3
640 S2W MDL NO B 40 4.7K OHM SLK-24F HD-3 HS-22D HB-3
640 S2W MDL NO B 40 4.7K OHM SLK-24FH HD-3 HS-22D HB-3
640 S2WA MDL NO D 50 N/A SIF-24F HD-2 HS-22D HB-3
640 S2WA MDL NO D 40 N/A SLK-24F HD-3 HS-22D HB-3
640 S2WA MDL NO D 40 N/A SLK-24FH HD-3 HS-22D HB-3
640/641 MX8/WIB MDL NO B 15 15 K SIF-24F HD-2 HS-200 D HD-20
640/641 MX8/WIB MDL NO B 50 4.7K SIF-24F HD-2 HS-200 D HD-20
640/641 MX8/WIB MDL NO B 11 15 K SIH-24F HD-3 HS-200 D HD-20
640/641 MX8/WIB MDL NO B 39 4.7K SIH-24F HD-3 HS-200 D HD-20
640/641 MX8/WIB MDL NO B 44 4.7K SLK-24F HD-3 HS-200 D HD-20
640/641 MX8/WIB MDL NO B 44 4.7K SLK-24FH HD-3 HS-200 D HD-20
640/641 MX8/WIB MDL NO B 13 15 K SLK-24FH HD-3 HS-200 D HD-20
640/641 S2/OSS MDL NO B 15 15 K SIF-24F HD-2 HS-200 D HD-20
640/641 S2/OSS MDL NO B 11 15 K SIH-24F HD-3 HS-200 D HD-20
640/641 S2/OSS MDL NO B 13 15 K SLK-24F HD-3 HS-200 D HD-20
640/641 S21/OSS MDL NO B 13 15 K SLK-24FH HD-3 HS-200 D HD-20
640/641 S2A MDL NO D 15 15 K SIF-24F HD-3 HS-200 D HD-20
640/641 S2A MDL NO D 11 15 K SIH-24F HD-3 HS-200 D HD-20
640/641 S2A MDL NO D 13 15 K SLK-24F HD-3 HS-200 D HD-20
640/641 S2A MDL NO D 13 15 K SLK-24FH HD-3 HS-200 D HD-20
640/641 S2W MDL NO B 50 4.7K SIF-24F HD-2 HS-200 D HD-20
640/641 S2W MDL NO B 44 4.7K SLK-24F HD-3 HS-200 D HD-20
640/641 S2W MDL NO B 44 4.7K SLK-24FH HD-3 HS-200 D HD-20
640/641 S2WA MDL NO D 50 4.7K SIF-24F HD-2 HS-200 D HD-20
640/641 S2WA MDL NO D 39 4.7K SIH-24F HD-3 HS-200 D HD-20
640/641 S2WA MDL NO D 44 4.7K SLK-24F HD-3 HS-200 D HD-20
640/641 S2WA MDL NO D 44 4.7K SLK-24FH HD-3 HS-200 D HD-20
641 MX8/WIBH MDL NO B 50 4.7K OHM SIF-24F HD-2 HS-22D HB-3
641 MX8/WIBH MDL NO B 40 4.7K OHM SLK-24F HD-3 HS-22D HB-3
Page 1 of 2
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989
Page 2 of 2
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989
UPTIME
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
1A N/A ZA/B B 30 10K OHM SIF-24F HD-2 HS-21D HB-2
1A N/A ZA/B B 24 10K OHM SLK-24F HD-3 HS-21D HB-2
1A N/A ZA/B B 24 10K OHM SLK-24FH HD-3 HS-21D HB-2
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989
VIKING
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
PAR-3, B-1 N/A A BD 30 71252 SIH-24F HD-3 HSB-220 HB-56
PAR-3, B-1 N/A A BD 30 71252 SIH-24F HD-3 HSB-224 HB-54
PAR-3, B-1 N/A A BD 30 71252 SLK-24F HD-3 HSB-220 HB-56
PAR-3, B-1 N/A A BD 30 71252 SLK-24F HD-3 HSB-224 HB-54
PAR-3, B-1 N/A A BD 30 71252 SLK-24FH HD-3 HSB-220 HB-56
PAR-3, B-1 N/A A BD 30 71252 SLK-24FH HD-3 HSB-224 HB-54
LIST OF COMPATIBLE CONTROL UNITS AND SMOKE DETECTORS 22-Oct-2002
LISTED AFTER MARCH 1, 1989
WORMALD
2-Wire Compatibility Listings
PANEL MODEL ZONE MODEL ZONE LOOP MAX EOL DETECTOR MODEL DETECTOR BASE MODEL BASE ID
ID STYLE DET ID
AUTOPULSE 1000 N/A SZB1 B 75 68710 SLK-24F HD-3 DB-201N HB-2
AUTOPULSE 1000 N/A SZB1 B 75 68710 SLK-24F HD-3 DBR-202N HB-7
AUTOPULSE 2000 N/A M6D1 D 45 N/A SLK-24F HD-3 DB-201N HB-2
AUTOPULSE 2000 N/A M6B1 B 75 70061 SLK-24F HD-3 DB-201N HB-2
AUTOPULSE 2000 N/A M6B1 B 75 70061 SLK-24F HD-3 DBR-202N HB-7
AUTOPULSE 3000 N/A M6D1 D 45 N/A SLK-24F HD-3 DB-201N HB-2
AUTOPULSE 3000 N/A M6B1 B 75 70061 SLK-24F HD-3 DBR-202N HB-7
AUTOPULSE 3000 N/A M6B1 B 75 70061 SLK-24F HD-3 DI-201N HD-2
AUTOPULSE 4000 N/A M20D1 D 40 N/A SLK-24F HD-3 DB-201N HB-2
AUTOPULSE 4000 N/A M20B1 B 75 70061 SLK-24F HD-3 DBR-202N HB-7
AUTOPULSE 4000 N/A M20B1 B 75 70061 SLK-24F HD-3 DI-201N HB-2
MULTIZONE 20M N/A M20D1 D 40 N/A SLK-24F HD-3 DB-201N HB-2
MULTIZONE 20M N/A M20B1 B 75 70061 SLK-24F HD-3 DBR-202N HB-7
MULTIZONE 20M N/A M20B1 B 75 70061 SLK-24F HD-3 DI-201N HB-2
MULTIZONE 20P N/A M20B1 B 75 70061 SLK-24F HD-3 DB-201N HB-2
MULTIZONE 20P N/A M20D1 D 40 N/A SLK-24F HD-3 DB-201N HB-2
MULTIZONE 20P N/A M20B1 B 75 70061 SLK-24F HD-3 DBR-202N HB-7
MULTIZONE 6P N/A M6D1 D 45 N/A SLK-24F HD-3 DB-201N HB-2
MULTIZONE 6P N/A M6B1 B 75 70061 SLK-24F HD-3 DBR-202N HB-7
MULTIZONE 6P N/A M6B1 B 75 70061 SLK-24F HD-3 DI-201N HB-2
CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM
LISTING SERVICE
LISTING No. 7272-0410:0107 Page 1 of 1
LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3248 Fax (714) 522-2268
Email: mum@hochiki.com
DESIGN: Models SLG-12, SLG-24, SLG-24FH, SLG-24F, SLK-12, SLK-24F, SLK-24FH, SLK-24FB,
SLK-24FL, SLK-24FLB, SLK-835, SLK-835H, SLR-835, SLR-835W, SLR-835B-2,
SLR-835B-4, SLR-835B-2W, SLR-835B-4W, SLR-24, SLR-24H, SLR-24V, *SLR-24VN,
SLR-835H, SLR-835HW, SLR-835BH-2, SLR-835BH-2W, SLR-835BH-4, SLR-835BH-4W
photoelectric type smoke detectors. Unit with suffix -H or -FH employs a supplemental heat
sensor. Refer to listee's data sheet for additional detailed product description and operational
considerations.
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction.
APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm
control units when used in conjunction with listee's listed bases (CSFM Listing No.
7300-0410:132). Models with supplemental heat sensor are not approved for use in lieu of
required heat detectors.
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
LISTING SERVICE
LISTING No. 7270-0410:0119 Page 1 of 1
LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3248 Fax (714) 522-2268
Email: mum@hochiki.com
DESIGN: Models AL-DFE-135 and AL-DFE-190. Refer to listee's data sheet for detailed product
description and operational considerations.
INSTALLATION: In accordance with the listee's printed installation instructions, applicable codes and
ordinances and in a manner acceptable to the authority having jurisdiction.
MARKING: Listee's name, model number, temperature & electrical ratings and UL label.
APPROVAL: Listed as system heat detectors when used in conjunction with listed compatible bases
(CSFM Listing No. 7300-0410:132) and separately listed compatible control units.
*Rev 11-16-2000
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
LISTING SERVICE
LISTING No. 7300-0410:0132 Page 1 of 2
LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3248 Fax (714) 522-2268
Email: mum@hochiki.com
DESIGN: Detector bases (2 and 4-wire). Unit is intended for use with a separately listed compatible
detector head. Refer to listee's data sheet for detailed product description and operational
considerations. Models listed below.
*Rev 01-12-12 gt
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances
and in a manner acceptable to the authority having jurisdiction.
APPROVAL: Listed as bases for use with listee’s separately listed compatible smoke and heat detectors .
Refer to heat or smoke detector listings for compatibility. Models HA-2R, HA-SLR, HA-LRA2
and HSC Series w/ suffix R are also suitable for releasing device service . Model YBA-R3 is
intended for use with thermostat detector only.
NOTE: Formerly 7300-0410:100, 106, 115, 124, 125, 126, 130, 131 & 133
*Rev 01-12-12 gt
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
LISTING SERVICE
LISTING No. 7270-0410:0147 Page 1 of 1
LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3248 Fax (714) 522-2268
Email: mum@hochiki.com
DESIGN: Models ATG-EA and *FFO-HEATelectronic fixed temperature heat detector (analog) with
Models YBN-NSA-4, HSB-NSA-6, *FFO-4BASE or *FFO-6BASE bases. Unit consists of
resistors, capacitors, diodes, transistors, LED, thermistors, mounted on a printed wiring
board inside an enclosure. Refer to listee's data sheet for additional detailed product
description and operational considerations.
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction.
APPROVAL: Listed as heat detector for use with separately listed compatible fire alarm control units.
*Rev 01-12-12 gt
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
LISTING SERVICE
LISTING No. 7271-0410:0148 Page 1 of 1
LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3248 Fax (714) 522-2268
Email: mum@hochiki.com
DESIGN: Model AIE-EA analog addressable ionization type smoke detector with Models YBN -NSA-4
and HSB-NSA-6 bases. Unit consists of resistors, capacitors, diodes, transistors, LED,
diodes and ionization chamber, mounted on a printed wiring board inside an enclosure. Refer
to listee's data sheet for additional detailed product description and operational
considerations.
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction.
APPROVAL: Listed as ionization type smoke detector for use with separately listed compatible fire alarm
control units.
*Rev 11-16-2000
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
LISTING SERVICE
LISTING No. 7272-0410:0149 Page 1 of 1
LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3248 Fax (714) 522-2268
Email: mum@hochiki.com
DESIGN: Models ALG-EA and ALG-V analog addressable photoelectric type smoke detector with
Models YBN-NSA-4 and HSB-NSA-6 bases. Unit consists of resistors, capacitors, diodes,
transistors, LED, photo diode, mounted on a printed wiring board inside an enclosure. Refer
to listee's data sheet for additional detailed product description and operational
considerations.
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction.
APPROVAL: Listed as photoelectric smoke detector for use with separately listed compatible fire alarm
control units. *Model ALG-V is suitable for in duct use in air velocities up to 4000 ft/min.
NOTE:
*Rev 1-31-2008 mt
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
LISTING SERVICE
LISTING No. 7300-0410:0150 Page 1 of 1
LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3248 Fax (714) 522-2268
Email: mum@hochiki.com
Refer to listee's data sheet for additional detailed product description and operational
considerations.
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction.
APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control
units. Refer to listee’s Installation Instruction Manual for details .
*Rev. 01-12-12 gt
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
LISTING SERVICE
LISTING No. 7270-0410:0151 Page 1 of 1
LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3248 Fax (714) 522-2268
Email: mum@hochiki.com
DESIGN: Models DCD-135 and DCD-190, fixed temperature and rate of rise heat detectors. Refer to
listee's data sheet for additional detailed product description and operational considerations.
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances
and in a manner acceptable to the authority having jurisdiction.
APPROVAL: Listed as fixed temperature and rate of rise heat detector for use listed bases (CSFM Listing
No. 7300-0410:132) and separately listed fire alarm control units.
*Rev 11-16-2000
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
LISTING SERVICE
LISTING No. 7120-0410:0153 Page 1 of 1
LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3248 Fax (714) 522-2268
Email: mum@hochiki.com
DESIGN: Model HRAM-208 remote multiplex annunciator and HRTI-1 Remote trouble Indicator. Refer
to listee's data sheet for additional detailed product description and operational
considerations.
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction. For indoor use only.
APPROVAL: Listed as annunciator panel for use with listee's separately listed compatible Model HCP-200
Series fire alarm control unit (CSFM Listing No. 7165-0410:152).
XLF: 7120-1477:0108
*Rev 11-16-2000
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
LISTING SERVICE
LISTING No. 7165-0410:0154 Page 1 of 1
LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3248 Fax (714) 522-2268
Email: mum@hochiki.com
DESIGN: HCP-1000 fire alarm control unit. Non-coded, automatic, manual, local, auxiliary, remote
station, waterflow and sprinkler supervisory service. System components:
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances,
and in a manner acceptable to the authority having jurisdiction.
APPROVAL: Listed as fire alarm control units for use with separately listed electrically and functionally
compatible initiating and indicating devices.
This control unit can generate a distinctive three- pulse Temporal Pattern Fire Alarm
Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. Refer to
listee's Installation Manual for details.
This control unit meets the requirement of UL-864, 8th Edition Standard.
NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum
Retard/Reset/Restart period shall not exceed 30 seconds.
XLF: 7165-1477:0106
*Rev 11-16-2000
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
LISTING SERVICE
LISTING No. 3240-0410:0155 Page 1 of 1
LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3248 Fax (714) 522-2268
Email: mum@hochiki.com
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction.
APPROVAL: Listed as duct smoke detector units for use with separately listed compatible fire alarm
control units to detect an abnormal amount of smoke density in the return air ducts of air
conditioning and ventilating system. The air velocity in the duct shall be between 300-4000
fpm.
NOTE: For duct application only. Not suitable for open area protection.
*Rev 09-05-12 gt
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
LISTING SERVICE
LISTING No. 7120-0410:0157 Page 1 of 1
LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3248 Fax (714) 522-2268
Email: mum@hochiki.com
DESIGN: Model HRA-1000 remote multiplex annunciator panel. The main annunciator module provides
indication for 32 zones. Each adder annunciator module provides indication for 48 additional
zones. Unit includes main annunciator chassis HRAM-1032 and adder annunciator chassis
HRAX-1048. Refer to listee's data sheet for additional detailed product description and
operational considerations.
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction. For indoor use only.
APPROVAL: Listed as annunciator panel for use with listee's separately listed compatible Model
HPC-1000 fire alarm control unit (CSFM Listing No. 7165-0410:154).
XLF: 7120-1477:0107
*Rev 11-16-2000
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
LISTING SERVICE
LISTING No. 7260-0410:0158 Page 1 of 1
LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3248 Fax (714) 522-2268
Email: mum@hochiki.com
DESIGN: Model SRA-24 projected beam smoke detector. Unit consists of a transmitter/receiver unit
and a reflector unit. This device is intended for ceiling installation only between 25 to 100 ft
apart. Refer to the listee's data sheet for detailed product description and operational
considerations.
RATING: 24 VDC
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances
and in a manner acceptable to the authority having jurisdiction
APPROVAL: Listed as beam smoke detector for use with separately listed compatible fire alarm control
units. Refer to listee’s Installation Instructions Manual for details .
4-14-03 KK
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
LISTING SERVICE
LISTING No. 7165-0410:0159 Page 1 of 2
LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3248 Fax (714) 522-2268
Email: mum@hochiki.com
DESIGN: Model FireNet 4127 Analog Addressable fire alarm control unit. Automatic, manual, waterflow
and sprinkler supervisory service. Refer to the listee's data sheet for detailed product
description and operational considerations. System components:
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances,
and in a manner acceptable to the authority having jurisdiction.
APPROVAL: Listed as fire alarm control unit for use with separately listed compatible initiating and
indicating devices. *Also suitable for high-rise applications.
These control units can generate the distinctive three- pulse Temporal Pattern Fire Alarm
Evacuation Signal as required per NFPA 72, 2002 Edition.
This control unit meets the requirements of UL-864, *9th Edition Standard
NOTE: 1. For Fire Alarm Verification Feature (Delay of fire alarm), the maximum
*Rev 6-24-2009 fm
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
*Rev 6-24-2009 fm
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
LISTING SERVICE
LISTING No. 7300-0410:0161 Page 1 of 1
LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3248 Fax (714) 522-2268
Email: mum@hochiki.com
DESIGN: Model ASB detector sounder base. Unit has an intregral audible signal for use with spot-type
detector units. Refer to listee's data sheet for additional detailed product description and
operational considerations.
RATING:
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction.
APPROVAL: Listed as a detector base for use with separately listed functionally and electrically
compatible fire alarm control units. Designed specifically for use with listee’s Model ALG-V
(CSFM Listing No. 7272-0410:149) Photoelectric Smoke Detector; Model AIE-EA (CSFM
Listing No. 7271-0410:148) Ionization Smoke Detector; or Model ATG-EA (CSFM Listing No.
7270-0410:147) Heat Detector. Refer to listee’s Installation Instruction Manual for details .
NOTE: These appliances can generate a distinctive three- pulse Temporal Pattern Fire Alarm
Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition.
8-24-2004
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
LISTING SERVICE
LISTING No. 7150-0410:0162 Page 1 of 1
LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3248 Fax (714) 522-2268
Email: mum@hochiki.com
DESIGN: Models HPS-SAH, HPS/SAK, HPS-DAH, HPS-DAH/S, and HPS-SAH-WP with or without
the suffix DA-C non-coded manual pull stations. Refer to listee's data sheet for detailed
product description and operational considerations.
INSTALLATION: In accordance with listee's printed installation instructions and applicable codes and
ordinances and in a manner acceptable to the authority having jurisdiction.
APPROVAL: Listed as fire alarm manual pull stations for use with separately listed compatible fire alarm
control units. Model HPS-SAH-WP is suitable for outdoor use. Refer to listee’s Installation
Instruction Manual for details.
* These manual pull boxes do not meet the requirements of UL Standard 38, 1999 Edition
and California amendments.
XLF: 7150-1039:0101
*Updated 6-22-2009 fm
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
LISTING SERVICE
LISTING No. 7151-0410:0163 Page 1 of 1
LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3248 Fax (714) 522-2268
Email: mum@hochiki.com
DESIGN: Model HPS-SA-EX/WP with or without the suffix DA-C non-coded, explosion proof, weather
proof manual pull stations. These devices consist of a switch and terminal block mounted
within an explosion proof enclosure. Refer to listee's data sheet for additional detailed
product description and operational considerations.
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances,
and in a manner acceptable to the authority having jurisdiction.
APPROVAL: Listed as fire alarm manual pull stations for use with separately listed compatible fire alarm
control units. Suitable for use outdoor and in Class I, Group B, C and D; Class II, Group E, F
and G hazardous locations. Refer to listee’s Installation Instruction Manual for details .
*These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition with
California amendments except for models with suffixes -DAH.
XLF: 7151-1039:0104
*Updated 08-27-2009 fm
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
LISTING SERVICE
LISTING No. 7150-0410:0164 Page 1 of 1
LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3248 Fax (714) 522-2268
Email: mum@hochiki.com
DESIGN: Models HPS-CP and HPS/CP/S non-coded boxes. Refer to listee's data sheet for detailed
product description and operational considerations.
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances
and in a manner acceptable to the authority having jurisdiction.
APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control
units. Refer to listee’s Installation Instruction Manual for details .
* These manual pull boxes do not meet the requirements of UL Standard 38, 1999 Edition
and California amendments.
XLF: 7150-0512:0006
*Updated 6-22-2009 fm
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
LISTING SERVICE
LISTING No. 7120-0410:0165 Page 1 of 1
LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3248 Fax (714) 522-2268
Email: mum@hochiki.com
DESIGN: Model *FN-LCD-N Network LCD Annunciator and **Model FN-LCD-S Serial LCD Annunciator.
Connects to the control panel via the RS-485 network interface. Employs four Form C relays
that are unsupervised. **Up to 16 FN-LCD-S Serial LCD Annunciators can be connected to
one control panel. Refer to listee's data sheet for additional detailed product description and
operational considerations.
RATING: 24 VDC
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction.
APPROVAL: Listed as annunciator panel for use with listee's separately listed compatible Model FireNet
4127 fire alarm control unit (CSFM Listing No. 7165-0410:159). Refer to listee’s Installation
Instruction Manual for details.
NOTE:
*Recert 4-12-2007 jw
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
LISTING SERVICE
LISTING No. 7315-0410:0166 Page 1 of 1
LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3248 Fax (714) 522-2268
Email: mum@hochiki.com
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction
APPROVAL: Listed as power supply units for use with separately listed compatible fire alarm control
units. Refer to listee’s Installation Instruction Manual for details .
NOTE: The system must have the secondary power supply capable of operating the system for at
least 24 hours battery standby) in the normal condition and followed by not less than 5
minutes of alarm as required by code. The battery circuit must be fully supervised.
XLF: 7315-1335:0109
5-3-2005
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
LISTING SERVICE
LISTING No. 7315-0410:0168 Page 1 of 1
LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3248 Fax (714) 522-2268
Email: mum@hochiki.com
DESIGN: Models FN-600ULX-G, -R, -C, -B Power Supply Units. Refer to listee's data sheet for
additional detailed product description and operational considerations.
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction
APPROVAL: Listed as power supply units for use with separately listed compatible fire alarm control
units. Also suitable for use with access control systems. Authority having jurisdiction should
be consulted prior to installation.
NOTE: For fire alarm use, the standby batteries must provide at least 24 hours standby power during
power loss. The battery circuit must be fully supervised.
XLF: 7315-1335:0104
5-3-2005
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
LISTING SERVICE
LISTING No. 7150-0410:0169 Page 1 of 1
LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3248 Fax (714) 522-2268
Email: mum@hochiki.com
RATING: 33 Vdc
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction.
APPROVAL: Listed as fire alarm manual pull boxes for use with separately listed electrically and
functionally compatible fire alarm control units.
These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and
California amendments except models with "LP" ,*"DH", and *"DK" suffixes.
*Rev 01-12-12 gt
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
LISTING SERVICE
LISTING No. 7260-0410:0172 Page 1 of 1
LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3248 Fax (714) 522-2268
Email: mum@hochiki.com
DESIGN: Model SPC-24 Projected Beam, Smoke-Automatic Fire Detector. Unit consists of one
emitter unit and one receiver unit. Refer to listee's printed data sheet for additional product
description and operational consideration.
RATING: 24 VDC
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances
and in a manner acceptable to the authority having jurisdiction.
APPROVAL: Listed as beam smoke detectors for use with separately listed compatible fire alarm control
units.
NOTE:
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
LISTING SERVICE
LISTING No. 7272-0410:0173 Page 1 of 1
LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3248 Fax (714) 522-2268
Email: mum@hochiki.com
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction.
APPROVAL: Listed as photoelectric smoke detector for use with separately listed compatible fire alarm
control units. Also suitable for in-duct use in air velocities up to 4000 ft/min.
*Rev. 12-17-2009 fm
*Rev 01-12-12 gt
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
LISTING SERVICE
LISTING No. 7272-0410:0174 Page 1 of 1
LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3248 Fax (714) 522-2268
Email: mum@hochiki.com
DESIGN: Models SLV-24, SLV-24V, SLV-24N and SLV-24M* Conventional, Photoelectric Type Smoke
Detectors. Detectors are for use with listed Models NS4-220, NS4-224, NS6-220, NS6-224,
HSC-4R, HSC-220R, and HSC-224R Bases. Refer to listee's data sheet for detailed product
description and operational considerations.
RATING: 24 Vdc
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances
and in a manner acceptable to the authority having jurisdiction.
APPROVAL: Listed as photoelectric smoke detectors for use with listed bases as shown in “DESIGN” and
compatible listed fire alarm control units.
3-19-2008
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
LISTING SERVICE
LISTING No. 6911-0410:0175 Page 1 of 1
LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3248 Fax (714) 522-2268
Email: mum@hochiki.com
DESIGN: Models FNV-MP and FNV-DP audio adjunct/voice evacuation systems. The FNV-MP is the
master panel in the system while the FNV-DP is the distributed panel. Each system is
modular in construction. Refer to listee's data sheet for additional detailed product
description and operational considerations. System components:
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction.
XLF: 6911-1446:0103
*Corrected 03-14-11 bh
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
LISTING SERVICE
LISTING No. 6911-0410:0176 Page 1 of 1
LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3248 Fax (714) 522-2268
Email: mum@hochiki.com
DESIGN: Models EVAX 25, -25E, -50, -50E, -100, -100E, -150, -150E, -200, -200E audio adjunct
system. These units are intended to be used in conjunction with a listed electrically
compatible fire alarm control unit to provide voice communication, paging, evacuation tone
signals, and voice alarm signals with voice override. Refer to listee's data sheet for detailed
product description and operational considerations.
INSTALLATION: In accordance with listee's printed installation instructions, wiring diagram, applicable codes
and ordinances and in a manner which is acceptable to the authority having jurisdiction.
XLF: 6911-1446:0100
8-28-2008 bh
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
LISTING SERVICE
LISTING No. 6912-0410:0177 Page 1 of 1
LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3248 Fax (714) 522-2268
Email: mum@hochiki.com
DESIGN: Model EVX-4Z and EVX-2ZA zone splitters. The unit is intended to be used in conjunction
with a listee's separtely listed Model EVAX-25 audio adjunct system (CSFM Listing No.
6911-0410:176). Refer to listee's data sheet for detailed product description and operational
considerations.
INSTALLATION: In accordance with listee's printed installation instructions, wiring diagram, applicable codes
and ordinances and in a manner which is acceptable to the authority having jurisdiction.
XLF: 6912-1446:0101
8-28-2008 bh
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
LISTING SERVICE
LISTING No. 7270-0410:0178 Page 1 of 1
LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3248 Fax (714) 522-2268
Email: mum@hochiki.com
DESIGN: Models DSC-EA Rate-of-rise heat detector. Refer to listee's data sheet for detailed product
description and operational considerations.
RATING: 24 VDC
INSTALLATION: In accordance with the listee's printed installation instructions, applicable codes and
ordinances and in a manner acceptable to the authority having jurisdiction.
APPROVAL: Listed as heat detector when used in conjunction with listed compatible HSB-100 base
(CSFM Listing No. 7300-0410:132) and separately listed compatible control units.
12-15-2009 fm
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
LISTING SERVICE
LISTING No. 3242-0410:0179 Page 1 of 1
LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3248 Fax (714) 522-2268
Email: mum@hochiki.com
DESIGN: Model ALK-D duct smoke detector, analog, addressable photoelectric type sensor. Refer to
listee's data sheet for additional detailed product description and operational considerations.
INSTALLATION: The unit is intended to be installed to and mounted in air ducts with airflows up to 4000
ft/min. In accordance with listee's printed installation instructions and applicable codes and
ordinances and in a manner acceptable to the authority having jurisdiction.
APPROVAL: Listed as photoelectric type, duct smoke detectors for use with separately listed compatible
fire alarm control unit, Hochiki Model FireNet 4127 (CSFM Listing No. 7165-0410:159). The
unit is for use with listed compatible bases, Hochiki Model YBN-NSA-4 or HSB-NSA-6
(CSFM Listing No. 7300-0410:132). Suitable for use in ducts with airflows up to 4000 ft/min.
Refer to listee’s Installation Instruction Manual for details .
12-16-2009 fm
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
LISTING SERVICE
LISTING No. 7165-0410:0180 Page 1 of 1
LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3248 Fax (714) 522-2268
Email: mum@hochiki.com
DESIGN: Models FIRENET PLUS 1127 Series. Analog Addressable Fire Alarm System. May be
followed by suffixes -R or -C which represents the color of the panel enclosure, -R for red, -C
for charcoal. Local, manual and automatic, sprinkler supervisory and waterflow services.
Refer to listee's data sheet for additional detailed product description and operational
considerations. System components:
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction.
APPROVAL: Listed as fire alarm control units for use with listed compatible indicating and initiating devices.
Also suitable for high rise applications.
These control units generate a distinctive temporal pattern (Temporal Pattern Fire Alarm
Evacuation) for total evacuation in accordance with NFPA 72, 2002 Edition. This control unit
meets the requirements of UL Standard 864, 9th Edition.
NOTE: 1. For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum
Retard/Reset/Restart period shall not exceed 30 seconds.
XLF: 7165-1714:0115
*Rev. 04-26-10 bh
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
LISTING SERVICE
LISTING No. 7120-0410:0181 Page 1 of 1
LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3248 Fax (714) 522-2268
Email: mum@hochiki.com
DESIGN: Model FNP-LED Graphix LED eMatrix Mimic Display, where X can be the number 1 or 2
denotes color of the enclosure, and -YYY denotes the number of LED extension boards
which could be 1, 3 or 5 boards.
Refer to listee's data sheet for additional detailed product description and operational
considerations.
RATING: 24 VDC
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction.
APPROVAL: Listed as annunciators for use with listee’s separately listed compatible fire alarm control
units. Refer to manufacturer’s Installation Manual for details .
03-01-10 fm
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
LISTING SERVICE
LISTING No. 7272-0410:0182 Page 1 of 1
LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3248 Fax (714) 522-2268
Email: mum@hochiki.com
DESIGN: Model ACA-V multi-sensor (photoelectric/heat) type detector. This model employs a 135°F
-150°F integral heat sensor. A fire alarm condition may be generated by the presence of
smoke or heat. Sensor may operate in a single (heat or photoelectric) or multi mode (heat &
photoelectric). Refer to listee's data sheet for additional detailed product description and
operational considerations.
RATING: 24 - 41 VDC
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in manner acceptable to the authority having jurisdiction.
APPROVAL: Listed as photoelectric type smoke detector for use with listee's separately listed compatible
base and fire alarm control units. Also acceptable for duct application with air velocities from
0-4000 ft/min. Listed as heat type detector for use with listee's separately listed compatible
base and fire alarm control units. Listed temperature range for the heat portion is 135°F -
150°F. Refer in Manufacturer's Installation Instruction Manual for details.
08-12-10 fm
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
LISTING SERVICE
LISTING No. 7165-0410:0183 Page 1 of 1
LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3248 Fax (714) 522-2268
Email: mum@hochiki.com
DESIGN: Models HCA-2, HCA-4, HCA-8 fire alarm control units. *"D" suffix to models adds
off-premises signaling utilizing a DACT. Non-coded; automatic, manual, local, remote
station, central station, waterflow and sprinkler supervisory service. System components:
RATING: 120/240VAC
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances,
and in a manner acceptable to the authority having jurisdiction.
MARKING: Listee's name, model number, electrical rating and ETL label.
APPROVAL: Listed as fire alarm control units for use with separately listed electrically and functionally
compatible initiating and indicating devices.
NOTE: For Fire Alarm Verification Feature, the maximum Retard/Reset/Restart period shall not
exceed 30.0 seconds.
*Rev 03-29-12 gt
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
LISTING SERVICE
LISTING No. 7165-0410:0184 Page 1 of 1
LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3248 Fax (714) 522-2268
Email: mum@hochiki.com
DESIGN: FireFocus Model FFO-1127-X where X represents R or C where R is for Red and C is for
Charcoal, fire alarm control unit. Refer to listee's data sheet for additional detailed product
description and operational considerations. System components:
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction.
APPROVAL: Listed as fire alarm control units for use with listed compatible indicating and initiating
devices.
Also suitable for high rise applications.
These control units generate a distinctive temporal pattern ( Temporal Pattern Fire Alarm
Evacuation) for total evacuation in accordance with NFPA 72, 2010 Edition. This control unit
meets the requirements of UL Standard 864, 9th Edition.
NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum
Retard/Reset/Restart period shall not exceed 30 seconds.
06-02-11 fm
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
LISTING SERVICE
LISTING No. 7120-0410:0185 Page 1 of 1
LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3248 Fax (714) 522-2268
Email: mum@hochiki.com
DESIGN: Model FFO-LCD-S-X Remote Annunciator, were -X represents R for red or C for Charcoal in
color. Annunciator is intended to connect to the Hochiki FireFocus FACP Model FFO -1127-R
(-C).
RATING: 24 VDC
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction.
APPROVAL: Listed as an annunciator for use with listee’s separately listed Model FFO -1127-R (-C) fire
alarm control unit. Refer to manufacturer’s Installation Manual for details .
Issued 7-22-11 mt
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
LISTING SERVICE
LISTING No. 7300-0410:0186 Page 1 of 1
LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3248 Fax (714) 522-2268
Email: mum@hochiki.com
DESIGN: Models SCI-B4 and SCI-B6 Detector Isolator Bases. These models are to be used with
listee's Models ACA-V, ALG-V, ALK-V, AIE-EA, and ATG-EA detector heads. The Model
SCI-B6 is similar to Model SCI-B4 except for base size, 6 " base versus 4" base.
RATING: 17 - 41 VDC
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction.
APPROVAL: Listed for use as detector bases with Manufacturer' s Models ACA-V, ALG-V, ALK-V,
AIE-EA, and ATG-EA detector heads. Refer to manufacturer's installation instruction and
manual for details.
Issued 7-11-11 mt
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
LISTING SERVICE
LISTING No. 7135-0410:0187 Page 1 of 1
LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3248 Fax (714) 522-2268
Email: mum@hochiki.com
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances
and in a manner acceptable to the authority having jurisdiction.
APPROVAL: Listed as horns and horn/strobes for use with separately listed compatible fire alarm control
units. For indoor use only.
The audible in Models HEH24, HEC24, HEC3-24 may produce distinctive tones including:
mechanical, 2400Hz and chime tones in continuous and temporal 3 settings as well as a
whoop tone in either a high or low dBA setting.
XLF: 7135-0569:0122
08-02-11 bh
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
LISTING SERVICE
LISTING No. 7125-0410:0188 Page 1 of 1
LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3248 Fax (714) 522-2268
Email: mum@hochiki.com
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances
and in a manner acceptable to the authority having jurisdiction.
APPROVAL: Listed as strobe lights suitable for the hearing impaired for use with separately listed
compatible fire alarm control units.
XLF: 7125-0569:0123
08-03-11 bh
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
LISTING SERVICE
LISTING No. 7300-0410:0189 Page 1 of 1
LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3248 Fax (714) 522-2268
Email: mum@hochiki.com
DESIGN: Models HGOE-R and HGOE-W enclosures. For indoor use only. Refer to listee's data sheet
for additional detailed product description and operational considerations.
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances
and in a manner acceptable to the authority having jurisdiction.
APPROVAL: Listed as a back box and enclosure for use with separately listed audible and visual
appliances.
XLF: 7300-0569:0124
08-05-11 bh
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
LISTING SERVICE
LISTING No. 7135-0410:0190 Page 1 of 1
LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3248 Fax (714) 522-2268
Email: mum@hochiki.com
DESIGN: Model HX91-R, HX91-W, HX93-R and HX93-W horns. Model HX-93 has selectable continuous
or temporal tones. Refer to listee's data sheet for additional product description and
operational considerations.
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances
and in a manner acceptable to the authority having jurisdiction.
APPROVAL: Listed as horns for use with separately listed compatible fire alarm control units. For indoor
use only.
Unit can generate the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal
(for total evacuation).
XLF: 7135-0569:0126
08-05-11 bh
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
LISTING SERVICE
LISTING No. 7135-0410:0191 Page 1 of 1
LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3248 Fax (714) 522-2268
Email: mum@hochiki.com
DESIGN: Model WHES24-75WR and WHES24-75WW strobe lights. Units employ a strobe flash tube
and electronic trigger circuit mounted on a printed wiring board with a clear lens. Unit is
intended for indoor use, or outdoor use when combined with enclosure Model HGOE only.
Unit is for private mode signaling use only. Refer to listee's data sheet for additional product
description and operational considerations.
Candela: 75cd
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances
and in a manner acceptable to the authority having jurisdiction.
APPROVAL: Listed as strobe lights for use with separately listed compatible fire alarm control units. Not
approved for hearing impaired applications.
XLF: 7135-0569:0127
08-05-11 bh
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
LISTING SERVICE
LISTING No. 7125-0410:0192 Page 1 of 1
LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3248 Fax (714) 522-2268
Email: mum@hochiki.com
DESIGN: Model HES3-12WR, HES3-12WW, HES3-12PWR and HES3-12PWW strobe lights. Refer to
listee's data sheet for additional detailed product description and operational considerations
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances
and in a manner acceptable to the authority having jurisdiction.
APPROVAL: Listed as strobe lights suitable for the hearing impaired for use with separately listed
compatible fire alarm control units. Refer to listee’s Installation Instruction Manual for details .
XLF: 7125-0569:0129
08-08-11 bh
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
LISTING SERVICE
LISTING No. 7135-0410:0193 Page 1 of 1
LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3248 Fax (714) 522-2268
Email: mum@hochiki.com
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances
and in a manner acceptable to the authority having jurisdiction.
APPROVAL: Listed as horn and horn/strobes for use with separately listed compatible fire alarm control
units. For indoor use only. Refer to listee’s Installation Instruction Manual for details .
XLF: 7135-0569:0130
08-08-11 bh
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
LISTING SERVICE
LISTING No. 7320-0410:0194 Page 1 of 1
LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3248 Fax (714) 522-2268
Email: mum@hochiki.com
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances
and in a manner acceptable to the authority having jurisdiction. All models are intended for
indoor use only and are mounted in a listed double-gang backbox.
APPROVAL: Listed as speakers and speaker strobes for use with separately listed compatible fire alarm
control units. Models HSSPK24CLPPR, HSSPK24CLPPW, HSSPK24CLPR and
HSSPK24CLPW speaker strobes are suitable for the hearing impaired applications. For
indoor use only. Refer to manufacturer’s Installation Manual for details .
These devices do not generate a temporal pattern signal. If the distinctive three-pulse
Temporal Pattern Fire Alarm Evacuation signal (for total evacuation).
XLF: 7320-0569:0137
08-08-11 bh
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
LISTING SERVICE
LISTING No. 7320-0410:0195 Page 1 of 1
LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3248 Fax (714) 522-2268
Email: mum@hochiki.com
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances
and in a manner acceptable to the authority having jurisdiction.
APPROVAL: Listed as speakers and speaker strobes for use with separately listed compatible fire alarm
control units. Both models are suitable for the hearing impaired applications. For indoor use
only. Refer to manufacturer’s Installation Manual for details .
XLF: 7320-0569:0140
08-08-11 bh
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
LISTING SERVICE
LISTING No. 7315-0410:0197 Page 1 of 1
LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3248 Fax (714) 522-2268
Email: mum@hochiki.com
DESIGN: Models PE-6SN and PE-10SN Notification Appliance Circuit (NAC) Power Supply Units.
Refer to listee's data sheet for additional detailed product description and operational
considerations.
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction. For fire alarm use, the unit
must provide battery backup suitable for at least 24 hours.
APPROVAL: Listed as power supply units for use with separately listed compatible fire alarm control units
and notification appliances. Authority having jurisdiction should be consulted prior to
installation. The unit can be programmed to generate the three-pulse temporal fire alarm
evacuation signal (for total evacuation) in accordance with NFPA 72, 2010 edition.
XLF: 7315-0328:0189
10-31-11 mt
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
LISTING SERVICE
LISTING No. 7300-0410:0199 Page 1 of 1
LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3248 Fax (714) 522-2268
Email: mum@hochiki.com
DESIGN: Model TCF-142-M-ST media converter (serial to fiber optic) for use with fire alarm control unit.
Refer to listee's data sheet for additional product description and operational considerations.
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances
and in a manner acceptable to the authority having jurisdiction.
02-24-12 bh
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014
LISTING SERVICE
LISTING No. 7305-0410:0200 Page 1 of 1
LISTEE: Hochiki America Corporation7051 Village Drive, Ste. 100, Buena Park, CA 90621-2268
Contact: Michael Um (714) 670-3248 Fax (714) 522-2268
Email: mum@hochiki.com
DESIGN: "Type NM" Signaling Stations, Model PB-SA yellow station with a momentary octagonal
button (push and release). Refer to listee's data sheet for detailed product description and
operational considerations.
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances
and in a manner acceptable to the authority having jurisdiction.
APPROVAL: Listed as a push button abort swtich. For indoor use only.
NOTE: Units are not acceptable for use as fire alarm pull stations.
XLF: 7305-1416:0103
06-20-12 gt
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee’s data sheet, installation instructions and/or other
Date Issued: July 01, 2013 Listing Expires June 30, 2014