You are on page 1of 1

A B C D E

24000 88 A.D.
Architecture + Designs
6000 5500 8000 4500
UNIT 707 VICENTE MADRIGAL BLDG.
6793 AYALA AVE. MAKATI CITY
2662 2395 E-MAIL: info@88ad.ph
TEL NO.: 848 5621

4259
EXISTING FIRE EXIT
1999 1999 1999
MARK P. BERON
ARCHITECT

RH
RH
REG. NO : 19523 PTR. NO : 6960766 MANILA
TPD EXEC. OFC. EXEC. OFC. PRESIDENT
TPD
TIN NO : 202-191-721 DATE : JAN. 03, 2018

3312
4
RH

RH

TPD

MALE TPD
ADDITIONAL RA 9266 SEC 33
WORKSTATIONS
TOILET RH
FEMALE
FIXED GLASS
(PROPOSED) DRAWINGS AND SPECIFICATIONS AND OTHER

5165
(RENOVATION) TOILET CONTRACT DOCUMENTS DULY SIGNED, STAMPED OR
A = ±13.88 SQM (RENOVATION) TPD FIXED GLASS FIXED GLASS
SEALED, AS INSTRUMENTS OF SERVICE ARE THE
3292 2430
HD HD INTELLECTUAL PROPERTY AND DOCUMENTS OF THE
A = ±13.00 SQM ARCHITECT, WHETHER THE OBJECT FOR WHICH THEY

FIXED GLASS
ARE MADE ARE EXECUTED OR NOT.IT SHALL BE
6750

9431
LOUNGE/ WORK TRANSIENT STAFF BUSINESS UNLAWFUL FOR ANY PERSON TO DUPLICATE OR TO
TPD TPD WD AREA AREA 1728 OPERATIONS OFFICE MAKE COPIES OF SAID DOCUMENTS FOR USE IN THE
(PROPOSED) A = ±43.49 SQM REPETITION OF AND FOR OTHER PROJECTS OR

2455
HS

1200
SLOP
BUILDINGS, WHETHER EXECUTED PARTLY OR WHOLE
1650

SINK

(EXISTING LAYOUT) WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT


JAN.
CABINET
OR THE AUTHOR OF SAID DOCUMENTS.
LOCKERS (LAPTOPS / MOBILE PHONES)

STORAGE / SUPPLIES PROJECT TITLE


1510

(PROPOSED) (EXISTING WORKSTATIONS) (EXISTING WORKSTATIONS)


3 A = ±8.97 SQM
PROPOSED MEDILINK OFFICE
MINOR RENOVATION

FIXED GLASS
INTERVIEW ROOM
4TH FLR. CIBI INFORMATION CENTER BLDG.
HR A = ±6.21 SQM 3308 ZAPOTE ST. MAKATI CITY
3194

A = ±9.63 SQM
(EXISTING WORKSTATIONS) PROJECT OWNER

30740
APPLICANTS
7750

SHELVES MEDILINK NETWORK INC.


1500

STORAGE

FIXED GLASS
26269

A = ±4.68 SQM PHARMACY

8300
(EXISTING WORKSTATIONS) A = ±41.58 SQM
ISS (EXISTING LAYOUT)
DATA
FIXED GLASS

A = ±9.53 SQM
2200

A = ±6.95 SQM (FORMER TRANSIENT Revisions


(ENCLOSURE STAFF AREA)
ONLY) No. Date Description

2 AUG. 30 2018 SCHEMATIC FLOOR PLAN


(EXISTING WORKSTATIONS) (EXISTING WORKSTATIONS)
PE - 1 PE - 2

PSD

(EXISTING WORKSTATIONS)
±3400

RECEPTION
8750

ELEVATOR LOBBY

4470
OFFICE

FIXED GLASS
DUST
(EXISTING) COLLECTOR
/ RUG
A = ±22.85 SQM
(EXISTING)
UR
UP DN

(EXISTING WORKSTATIONS) REMARKS:


FIXED GLASS FIXED GLASS FIXED GLASS

EE ROOM
(EXISTING)
OFFICE

3830
MEETING MEETING (MINOR RENOVATION) STORAGE SHEET CONTENT
1 ROOM
(EXISTING)
ROOM
(EXISTING)
A = ±18.94 SQM (PROPOSED)
OFFICE A = ±18.33 SQM
A = ±14.50 SQM A = ±14.91 SQM PROPOSED 4TH FLOOR PLAN
2000

(PROPOSED )
A = ±5.93 SQM (MEDILINK)
LEGEND:

WD : WATER DISPENSER
HD : AUTOMATIC HAND DRYER
SD : AUTOMATIC SOAP DISPENSER 2440 3500 3600 4600 4350

TPD : TOILET PAPER DISPENSER 23800


RB : ROBE HOOK Drawn By: Drawing No.
PSD : PLASTIC SLEEVE DISPENSER
88AD
(UMBRELLA) SCHEME
Checked By:
UR : UMBRELLA RACK
HS : AUTOMATIC HAND SANITIZER
DISPENSER A-01
1 PROPOSED 4TH FLOOR PLAN A-01
SCALE 1:150M Date: AUG. 30, 2018