Micro motion mass flow transmitter data sheet

GENERAL REFERENCE
Micromotion serial # M31628-2-D
Customer reference 9311053/V
Date 10-11-1993
Remarks
SENSOR
Model # DS025S
Serial # M31874-2
Tag No 2220-FE-4717B
Material 316 L
Flange 1/2” WN 600RJ
Tube 1900 psig
Conn. 1200 psig
Liner Unknown
ELECTRONICS
Model # RFT9729/A1PRFAA1
Serial # M31331-03
Voltage 115 VAC
Tag No 2220-FT-4717B
OUTPUT VARIABLES
Current : Represents flow
Low range 0.00000
High range 60.00000
Added damping 0.00 sec
Frequency : Represents flow
Output setpoint 10000 Hz
Rate setpoint 60.00000
DIGITAL VARIABLES
Density
Low cutof 0.00000 g/cc
High cutof 10.00000 g/cc
Flow
Direction Forward only
Rate 60.00000
Damping 1.60 sec
Cutof 0.30000
Units
Flow Kg/Hr
Density g/CuCm
Temperature Deg C
Alarm Down
Calibration variables
Flow factor 3.09445.13
Density factor 11499125964.44
K-TRON mass flow transmitter reference data

Tag # 2220-FT-4727B
Application/line/location Liquid additive mass flow sensor (PI control) P08-ABCD
Area classification Zone 2 dust, Gas groups A, B . T3, Zone “Y”
Certification required EEx ib II C T6
Certifying authority P.T.B.
Ambient temperature 0 – 40 deg C
Ingress protection IP65
Body material AISI 304 SS housing / wetted parts AISI 316 L
Line size 1/2” NB
Body conn./rating ANSI 1/2” Flange, 600# rated
Pipe schedule By client
Flow direction Horizontal
Signal conn. 3/4” NPT
Supply 110 V AC, 1 phase
Output signal 0 – 10 KHz
Max. range 60 kg/hr
Min. range 0 kg/hr
Calibrated range 4.5 – 22.5 kg/hr
Meter DP at max range ~ 0.25 barg
Accuracy +/- 0.2 % of rate
Process fluid WESTON 399 additive oil
State at operating conditions Liquid
Flow min./norm./max. 4.5/ /22.5 kg/hr
Pressure min./norm./max. Max 53 barg
Temperature min./norm./max. Norm 70 deg C
Density SG 0.987
Viscosity 100 cP to 250 cP
Upstream straight lengths By client