You are on page 1of 1

8 7 6 5 4 3 2 1

REVISION HISTORY
REV DESCRIPTION DATE APPROVED

EC 1174423-4 DSHARP MAR-2013


MAIN TERMINAL BLOCK WIRING DIAGRAM 3 CHAUTA

CAN POWER POWER IN -


1 13
CAN SHIELD POWER IN -
2 14
H M3 X 0.5 (METRIC) SOC SET SCREW. CAN GROUND POWER IN + H
TAMPERPROOF LOCK FOR ACCES COVER
3 15
CAN LOW POWER IN +
4 16
CAN HIGH RS485 SHIELD
5 17
ANALOG IN SHIELD RS485 -
1 6 18
8.730
[221.74] ANALOG IN - RS485 COMMON
7 19
ANALOG IN + RS485 +
3 8 20
HEX 1.240
SHUTDOWN SHIELD SHUTDOWN -
[31.5] 9 21
1
4.365 ANALOG OUT SHIELD SHUTDOWN +
[110.87] 10 22
G ANALOG OUT - STATUS OUT LOW G
THREADED ACCESS COVER 11 23
ACCESS TO ELECTRICAL
TERMINAL STRIP ANALOG OUT + STATUS OUT HIGH
TORQUE TO 35 FT-LBS
12 24

1 1 5.162
[131.11
]
4.724
[119.99] 4.365
[110.87] 2.581
1 [65.56]
8.730
[221.74] CONDUIT CONNECTION
1 1 .750-14 NPT CONDUIT CONNECTION
.500 .750-14 NPT
4.055 [12.7]
[103]

F EXTERNAL EARTH F
GROUND CONNECTION

4X .250-28 UNF-2B THREAD

E E
1
12.985
[329.82]

CENTER OF GRAVITY 1
1 10.810
[274.57] 1
16.098 2.750 9.725
[408.89] [69.85] [247.02]

(5.270 )
[133.86]

D 3.500 D
[88.9]

2X .703
[17.86] 2X 1.406
[35.71]

CENTER OF GRAVITY
OVERBOARD VENT 2X 1.500 FLANGED PIPE 1
CONNECTION .438-20 CONNECTION PER 3.113 1.500 FLANGED PIPE
SAE (-04) STRAIGHT SAE J518, CODE 61 [79.07] CONNECTION PER
THREAD PORT (MS 16142) SAE J518, CODE 61

C 2X 1.375
1
C
[34.93]
(.043 ) (.043 ) 3.400
[1.09] [1.09] [86.36]

FLOW 2X 2.750
[69.85] 1
5.800
[147.32]

FLOW

B B
2.100 NOTES:
1
[53.34]
FOR FIRST ARTICLE INSPECTION (FAI) REQUIREMENTS,
1 SEE WOODWARD 4-09-2704.

2. APPROXIMATE WEIGHT 45 LB (20.4 KG).

3
TO BE USED FOR ACCESS COVER REMOVAL. INCHES
UNITS =
2.100
[53.34]
1 [MM]

"THIS DRAWING OR ANY REPRODUCTION OF IT SHALL NOT BE USED FOR MANUFACTURE, PRODUCTION OR PROCUREMENT WITHOUT THE EXPRESS WRITTEN PERMISSION OF WOODWARD, INC. OR ONE OF ITS SUBSIDIARIES.
USE OR REPRODUCTION FOR USE IN A NORMAL MANNER ASSOCIATED WITH GOODS OR SERVICE FURNISHED OR TENDERED BY WOODWARD, INC. OR ONE OF ITS SUBSIDIARIES, IS APPROVED."
MATERIALS: APPROVED DATE
UNLESS OTHERWISE SPECIFIED, FORT COLLINS
DIMENSIONS ARE IN INCHES. COLORADO

A DRAWING DEFINITIONS AND


TOLERANCES SHALL BE FOUND
CHAUTA
CHECKED
NOV-2012
DATE TITLE
USA
A
IN SS-112.
THIRD ANGLE PROJECTION
CHAUTA
DRAWN
NOV-2012
DATE
VALVE
INSTALLATION DRAWING OF WT6 WATER VALVE
2X .438-20 UNF-2B MOD STRAIGHT THREAD DSHARP NOV-2012
PORT SAE (-04) PER WOODWARD SS-145 SIZE CAGE CODE DWG NO REV
(MS 16142)
E 31361 9989-4430 3
SCALE
NTS SHEET
1 OF 1

8 7 6 5 4 3 2