You are on page 1of 1

Project Spreadsheets to BS 8110 etc The Concrete Centre

Client Advisory Group Made by Date Page


Location Grid line 2 rc 29-Mar-2019 130
Basement wall design to BS8110:2005 Checked Revision Job No
Originated from 'RCC61 Basement Wall.xls' v4.0 © 2006 TCC chg - R68

OUTER BASE ( per metre length ) BS8110


gf = 1.50 (ASSUMED) reference
Ult. Shear = -7.33 kN (AT d from FACE of WALL)
Ult. MT. = 7.62 kNm TENSION - BOTTOM FACE

2
BOTTOM REINFORCEMENT : Min. As = 650 mm Table 3.25
f= 16 mm
centres = 200 mm < 766 OK
As = 1005 mm2 > 650 OK

MOMENT of RESISTANCE : d= 452 mm


Z= 429 mm 3.4.4.4
As' = 0 mm2
Mres = 189.12 kNm > 7.62 OK

SHEAR RESISTANCE: 100As/bd = 0.49%


vc = 0.43 N/mm2 Table 3.8
Vres = 193.62 kN > -7.33 OK 3.5.5.2

CHECK CRACK WIDTH IN ACCORDANCE WITH BS8100/8007 : & shrinkage effects not included
Temp
X= 102.81 mm em = -0.00068 BS8007
Acr = 102.92 mm W= -0.16 mm < 0.30 OK App. B.2
NO CRACKING

INNER BASE ( per metre length )


Ult. Shear = 5.49 kN (AT d from FACE of WALL)
Ult. MT. = 8.71 kNm TENSION - BOTTOM FACE

BOTTOM REINFORCEMENT : Min. As = 650 mm2 Table 3.25


f= 16 mm
centres = 200 mm < 766 OK
As = 1005 mm2 > 650 OK

MOMENT of RESISTANCE : d= 452 mm


Z= 429 mm
As' = 0 mm2
Mres = 189.12 kNm > 8.71 OK 3.4.4.4

SHEAR RESISTANCE: 100As/bd = 0.22%


vc = 0.43 N/mm2 Table 3.8
Vres = 193.62 kN > 5.49 OK 3.5.5.2

CHECK CRACK WIDTH IN ACCORDANCE WITH BS8100/8007 : & shrinkage effects not included
Temp
X= 102.81 mm em = -0.00067 BS8007
Acr = 102.92 mm W= -0.16 mm < 0.30 OK App. B.2
NO CRACKING

REINFORCEMENT SUMMARY for BASE


Type f centres As Min. As
2 2
mm mm mm mm
TOP X 16 200 1005 650 OK
BOTTOM T 16 200 1005 650 OK
TRANSVERSE T 16 200 1005 650 OK