2 R53

2
TP9 TP8 R68 -
2
TP6 TP8 1 R49 J9-6
+
3
6 R91 R67

R41
-

R42
7 R26 RN4A U12A

R36

R35
5

R52
+ J9-5

R48
U15B RN2A R24 2
2 J10-31 J1-12 1 -
6
- R89 -
R31

1 3 7

R215
+
+
3 +
5 J9-7
J10-12 J1-31 U16A
U15A U16B
RN2B R23 R54

R37
RN4B
R69 -
6
7

R72
RESET COMMAND 5 R50 J9-8
+
FROM MD-0761, PG 2
U12B

R221
HIGH KV / INVERTER FAULT

R220
TO GENERATOR READY
DETECTOR CIRCUIT ON
CONTROL BOARD, D92 ANODE OVERVOLTAGE
SEE MD-0761, PG 2 +12V SIGNAL TO MD-0760, PG 2
+12V +12V +12V
HV ON SIGNAL D80 D81 D82 D93 CATHODE OVERVOLTAGE

R172
U37 TO MD-0767, PG 1 SIGNAL TO MD-0760, PG 2

10
A/D
INV 3 INV 2 INV 1

R208

R209

R210
VERTER 3 U33E
D69
kV INVERTER 1 J14-1
TP26 INVERTER 1

11
FAULT LATCH &
HIGH KV FAULT DETECTOR
LOGIC INVERTER J14-3
D63 DETECTOR (T3, U36, D83, ETC)
(U39B, U35F)
AND LATCH
(U31, U32A, U33A)

HV ON DETECTOR
CIRCUIT (U30C INVERTER 2 J15-1
JW3 INVERTER 2
U30D, Q6, ETC) “OR” FAULT LATCH & INV
125kV 150kV FAULT DETECTOR
LOGIC LOGIC INVERTER J15-3
(T4, U37, D84, ETC)
JUMPER POSITION: (U39C, U35E)
125kV GENERATORS
JUMPER “125kV” D87-D89, U35C
150 kV GENERATORS
JUMPER “150kV” INVERTER 3 J16-1
INVERTER 3
FAULT LATCH &
FAULT DETECTOR
D86 LOGIC INVERTER J16-3
(T5, U38, D85, ETC)
TP2 (U39D, U35D)
1

4
R25

R46
U22 +5V TP17 TP19
2 R26, R45
- 1 J10-7 J1-7
D/A 3+ D48

R132
VERTER 2- ERROR AMPLIFIERS

R171
R180
U14A 1 R71 R70
3+ INCLUDES U13B, U21A
R106 U24A U26A
2
J10-26 J1-26 R25, R44 U13A - D49 3 2 7
D35 - R107 6- 1
+ VCO
7
U13B
+
5+ INCLUDES U19, U20, DRIVE P
R43

+12V U21A U23, U25, U27, Q10 U24B U26B CONTINUED


U21B 5 6 4 5

R108
4
R175

D66
D70
Ir

HIGH RESONANT 3 R62


CURRENT LATCH 7 -
& LOGIC INVERTER +
2 D27-D30
(U32D, U33D)
R64

U15 CURRENT SENSE


R65
R63

R66

DRIVE ENABLE
T1 T2 COMMAND FROM
MD-0761, PAGE 2
-12V

J13-4 J13-1
GENERATOR CPU BOARD CONTROL BOARD

DRAWN DATE
H.T. PRIMARY CURRENT SENSE G. SANWALD 18 MAY 2000
FROM PAGE 2 CHECKED
S. BLAKE 18 MAY 2000
E1: 560 / 650 VDC (+) REFER TO MD-0786 FOR
K1 DRIVE CIRCUITS
* USED ON R&F K1 *
GENERATORS ONLY
J2-1
TO J14-1 INVERTER FAULT
J2-3 SIGNAL, TO PAGE 1
TO J14-3

J10-1 J1-1 MOSFET MOSFET


J10-2 J1-2 SWITCHES SWITCHES

E3

J10-3 J1-3
J10-4 J1-4 MOSFET MOSFET
SWITCHES SWITCHES
*
E4

E2: 560 / 650 VDC (-)


INVERTER BOARD #1

E1: 560 / 650 VDC (+)

J2-1
TO J15-1 INVERTER FAULT
J2-3 SIGNAL, TO PAGE 1
TO J15-3

J11-1 J1-1 MOSFET MOSFET


J11-2 J1-2 SWITCHES SWITCHES
GATE DRIVE CIRCUIT
E3
OR MOSFET INVERTER
NCLUDES Q19 TO Q26) J11-3 J1-3
J11-4 J1-4 MOSFET MOSFET
SWITCHES SWITCHES

E4

E2: 560 / 650 VDC (-)


INVERTER BOARD #2

E1: 560 / 650 VDC (+)

J2-1
TO J16-1 INVERTER FAULT
J2-3 SIGNAL, TO PAGE 1
TO J16-3

J12-1 J1-1 MOSFET MOSFET


J12-2 POWER MODE J1-2 SWITCHES SWITCHES
SELECT
E3
BOARD
J12-3 (REFER TO J1-3
J12-4 MD-0786) J1-4 MOSFET MOSFET
S SWITCHES SWITCHES

E4

E2: 560 / 650 VDC (-) J1-1 J1-4


CONTROL BOARD INVERTER BOARD #3 RESONANT BOARD

INDICO 100 GENERATORS USE ONE, TWO, OR THREE INVERTER


MODULES DEPENDING ON GENERATOR OUTPUT POWER H.T. PRIMARY CURRENT TO J13-1
SENSE, TO PAGE 1 TO J13-4

DRAWN DATE
G. SANWALD 18 MAY 2000
CHECKED
S. BLAKE 18 MAY 2000
HV ANODE
BOARD

J1
ANODE

C S
L

J3-8
TO J9-8 HV MULT
ASSY +
J3-7 (ANODE)
KV FEEDBACK TO J9-7
SIGNAL
TO PAGE 1 J3-5
TO J9-5
J3-6
TO J9-6

E9

HV MULT
ASSY-
E10 (CATHODE)

FROM
PAGE 2 L
C
S

HV CATHODE J2
TANK LID CATHODE
BOARD
BOARD

RESONANT BOARD PART OF H.V. OIL TANK

** ONE TUBE H.T. OUTPUTS ARE SHOWN. TWO TUBE


TANKS WILL HAVE A SECOND PAIR OF H.T. OUTPUTS
DRAWN DATE
G. SANWALD 18 MAY 2000
CHECKED
S. BLAKE 18 MAY 2000
E
REMARKS
NCE
kV REFERENCE OUTPUT, GENERATED BY THE CPU. SCALING IS 1 VOLT OUT = 15 kV OF GENERATOR OUTPUT.
kV FEEDBACK TO THE CPU. SCALING IS 1V = 20 KV OF GENERATOR OUTPUT.
HV ON SIGNAL. THIS IS “HIGH” (APPROXIMATELY 5 VDC) WHEN HIGH VOLTAGE IS ON, “LOW” (APPROXIMATELY 0 VDC) WHEN HIGH VOLTAGE IS OFF.
THE VOLTAGE AT TP17 AND TP19 SHOULD BE A 50% DUTY CYCLE SQUARE WAVE, RANGING IN FREQUENCY FROM APPROXIMATELY 80 kHz TO APPROXIMATELY 250 kHz, DEPENDING ON GENERATOR
OUTPUT POWER. SEE FIGURE 1.

12 VDC

0 VDC

FIGURE 1

DRAWN DATE
G. SANWALD 18 MAY 2000
CHECKED
S. BLAKE 18 MAY 2000
+5V J2-8 5.5 A 6.5 A JW1 SELECTS MAXIMUM
JW1 1 2 3 FILAMENT CURRENT
5.5 OR 6.5 AMPS

RN7C
J2-7

FIL BUFFER &


J2-9 CURRENT LIMIT ERROR
DS13 DS14 CIRCUIT AMPLIFIER &
+12V DRIVER CIRCUIT
GRN RED TP2
3
TO 2.1 V

RN2H
CURRENT OPTO-COUPLER TP1
U24 “ON” = NO FILAMENT FILAMENT FAULT J2-10
SINK C22
FAULT J10-4 J1-4 TO MD-0761, PAGE 2
BUFFER BUFFER /
5 1 J2-4 AMPLIFIER & T1 J5-4
+5V FILAMENT
FILAMENT CURRENT CURRENT RMS
U7
FEEDBACK SIGNAL COMPARATOR CONVERTER J4 J5-3
(SM) TO PAGE 2 J2-3
RN7E

4 2 J10-23 J1-23 RN4D CIRCUIT


R137 J3-10
HV Q15
+12V
DS11 DS12 RN2G
3 FILAMENT SUPPLY BOARD (SMALL)
J10-5 J1-5
GRN RED 5 1
TO 2.1 V U8 RN4C
CURRENT R136 HV / MA FAULT J2-6 5.5 A 6.5 A JW1 SELECTS MAXIMUM
U24 4 2 J10-24 J1-24 Q14 FROM MD-0761, JW1 1 2 3 FILAMENT CURRENT
SINK
PAGE 2 5.5 OR 6.5 AMPS
J2-5
BUFFER
OPTO-COUPLER
“ON” = NO HV / MA J3-2 J2-2 J3-8 BUFFER &
J2-9 CURRENT LIMIT
FAULT ERROR
CIRCUIT AMPLIFIER &
J3-10 J2-10 J3-7 DRIVER CIRCUIT
TP3
1 TP2
3
R10
J3-9 TP1
R5

U18 J2-10
13 - R7 C22
14 TP21 BUFFER /
D/A 12 + AMPLIFIER &
J2-2 T1 J5-2
VERTER FILAMENT
U14D TP1
1 FILAMENT CURRENT CURRENT RMS
R17 FEEDBACK SIGNAL COMPARATOR CONVERTER J8 J5-1
(LG) TO PAGE 2 J2-1 CIRCUIT
R11

U22 6 - R24 J10-9 J1-9 J3-6


7
D/A 5 +
FILAMENT SUPPLY BOARD (LARGE)
VERTER J10-28 J1-28 J3-5
U14B
INDICO 100 GENERATORS WITH OPTIONAL TWO FILAMENT BOARDS (TYPICALLY USED IN R&F
+5V GENERATORS) USE THE FILAMENT BOARD CONFIGURATION SHOWN ABOVE
RN11E

JW5 JUMPER POSITION: INDICO 100 GENERATORS WITH STANDARD SINGLE FILAMENT BOARD (TYPICALLY USED IN RAD
INDICO GENERATORS ONLY GENERATORS) USE THE FILAMENT BOARD CONFIGURATION SHOWN BELOW
JUMPER PINS 1-2
DS24 DS25 DO NOT USE JUMPER
POSITION 2-3
J2-6 5.5 A 6.5 A JW1 SELECTS MAXIMUM
LARGE SMALL JW5 JW1 1 2 3 FILAMENT CURRENT
OPTO-COUPLER
5.5 OR 6.5 AMPS
TO 2.1 V 1 2 3 “ON” = LARGE FOCUS J2-5
CURRENT SELECTED
U27 SINK U19, U16 “LG/SM REQUEST” 4 BUFFER &
J3-11 J2-9 CURRENT LIMIT
2 J10-17 J1-17 RN1A DETECTOR CKT TO J3-6, J3-5, J3-9, J3-10 ERROR
DATA BUFFER AND (U11C, Q2, ETC) ON CONTROL BOARD CIRCUIT AMPLIFIER &
LATCH DRIVER 1 5 DRIVER CIRCUIT
J10-36 J1-36 3
+5V U1 TP1
RN1B 2 4 J2-10
T1 C22
RN6E

OPTO-COUPLER
U24 “ON” = SMALL FOCUS +12V J2-4 RMS
BUFFER /
SELECTED RN2E FIL CURRENT FEEDBACK CONVERTER
J10-8 J1-8 J2-3 AMPLIFIER &
BUFFER SIGNAL (SM) TO PAGE 2 FILAMENT CIRCUIT J5-3
5 1 J2-2 CURRENT
FIL CURRENT FEEDBACK COMPARATOR J5-4
U10 SIGNAL (LG) TO PAGE 2 J2-1 TP2 +12V
4 2 RN4A J5-1
J10-27 J1-27 K1
R75 J2-11 K1
Q3 J5-2

FILAMENT SUPPLY BOARD (UNIVERSAL)


GENERATOR CPU BOARD CONTROL BOARD
DUE TO SPACE RESTRICTIONS, THIS PAGE SHOWS
DRAWN DATE
ONLY THE MAJOR FILAMENT BLOCKS. REFER TO G. SANWALD 12 MAY 2000
O PAGE 4 FOR LOGIC LEVELS, PAGE 3 FOR A MORE DETAILED FUNCTIONAL CHECKED
TC, REFERENCED BY DIAGRAM OF THE FILAMENT SUPPLY BOARD. S. BLAKE 12 MAY 2000
J3-4 J2-3
FILAMENT CURRENT FROM J2-4
FEEDBACK SIGNAL SM FILA
J3-3 J2-11 CONTI
(SM) FROM PAGE 1 FROM J2-3

J2 **
J5-1 J4-1 CATHODE
RGE J5-2 J4-2 S
C J3-2 J1-13
L FILAMENT CURRENT FROM J2-2
FEEDBACK SIGNAL LG FILA
J3-1 J1-32 CONTI
(LG) FROM PAGE 1 FROM J2-1
E1 5
8
J5-3 J4-3
TP4 TP5
MALL J5-4 J4-4
R163

R5

R6
CATHODE
H.T. BOARD 6- R4 J1-11
7
5+
RAD
R216 U30B R3 J1-30 CONTI
SUPPLY

R165

R164
RD H.T.TANK R213

2
- 6 9
R33, R32 3 TP6 TP7
J1 HV ANODE +
ANODE BOARD U9

R36
HIGH MA FAULT TO
GENERATOR READY

R17

R16
S C 7 +12V DETECTOR CIRCUIT
L TP2 TP3 ON CONTROL BOARD, R15
SEE MD-0761, PAGE 2 J2-1
R34 R212

R179
FLUOR
R14 J2-9 CONTI

R7

R9

10
ANODE OVERVOLTAGE D72
SIGNAL FROM MD-0759, PG 1 U33E
J3-1 J9-1 RN6C, RN6D R19 ANODE I

11
ANODE OVER- HIGH ANODE
6- CURRENT LATCH
7 CURRENT DETECTOR
& LOGIC INVERTER
R8

5+ (U18, RN9E-H, ETC.)


(U32C, U33C) D65
J3-2 J9-2 RN6A, RN6B U6B D95

R38
mA
TEST
E18 JACK
-

RESET COMMAND
+ FROM MD-0761, PG 2
E17
+12V

R177
R39 CATHODE OVERVOLTAGE D71
SIGNAL FROM MD-0759, PG 1
J3-4 J9-4 RN6G, RN6H CATHODE
HIGH CATHODE
CATHODE OVER-
2- CURRENT LATCH
1 CURRENT DETECTOR
R18

& LOGIC INVERTER


3+ (U17, RN9A-D, ETC.)
(U32B, U33B) D64
J3-3 J9-3 RN6F, RN6E U6A D96

L C
R40

S H.T.TANK
J2
CATHODE HV CATHODE TANK LID
BOARD BOARD DRAWN DATE
G. SANWALD 12 MAY 2000
CHECKED
PART OF HV OIL TANK CONTROL BOARD S. BLAKE 12 MAY 2000
MAXIMUM FILAMENT CURRENT SET MAX
LIMIT CIRCUIT CURRENT
6 ERROR AMPLIFIER, PWM REGULATOR,
JW1 AND FILAMENT CURRENT DRIVERS
TP25 TP24
3
R61 +
6.5 A

R57
2
-

1 5.5 A
RN8D U1A +35V
-12V
J3-11 RN9D 6-
7 R63
EEDBACK 5 +
AGE 2 J3-3
U30B D6

R62
RN9C RN3G 11
RN8C

Q6 Q12
J2-8 RN2A 6- TP3
7 RN5G RN4H U3
5+ -

6 J2-7 RN2B U1B +

U4B PWM
TP23 TP22 REGULATOR

RN3F
R67 J2-6 RN1A
R64

J2-5 RN1B
RN8B Q13

J10-32 RN9B 2- Q7
1 R59

RN3H
EEDBACK 3 + C22
AGE 2 J10-13
U30A
R60

J2-9
RN9A
RN8A

-35V
3 TP1 10
U37
11 J2-10 TP2 TP4
TP7 TP10 +12V

RN5D
R39 A/D K1
CONVERTER K1 IS FITTED ON “UNIVERSAL” (LARGE/SMALL) K1
R38

FILAMENT BOARDS. J8 IS FITTED ON LARGE


FILAMENT BOARDS, AND J4 IS FITTED ON
RN1D SMALL FILAMENT BOARDS. J8
J10-30 RN2D J2-11
9- R29
8 J4
EEDBACK 10 +
PAGE 2 J10-11 13 -
U15C 14
12 +
R34

RN2C
RN1C

U15D
R23

T1
J2-4 RN2C D12, 13
Q1 U7 D27, 28
U4A RMS
J2-3 RN2D +
12 1.7 V CONVERTER
U2A Ref -

TP11 TP14 -
J2-2 RN1C +
R50
R45

J2-1 RN1D
RN4C
-
J3-9 RN5C 2-
1 R79 +
EEDBACK 3+ U2B R21
AGE 2 J3-1
U23A
R88

RN5D
RN4D

FILAMENT CURRENT SENSE, RMS


R87

CONVERTER, AND FILAMENT FEEDBACK

DATA BUS
D0..D7
GENERATOR CPU BOARD FILAMENT SUPPLY BOARD

DRAWN DATE
G. SANWALD 12 MAY 2000
CHECKED
S. BLAKE 12 MAY 2000
E
REMARKS
NCE
FILAMENT REFERENCE OUTPUTS, GENERATED BY THE CPU. SCALING IS 1 VOLT OUT = 1 AMP OF FILAMENT CURRENT.
“HIGH” (APPROXIMATELY 5 VDC) = LARGE FOCUS SELECTED, “LOW” (APPROXIMATELY 0 VDC) = SMALL FOCUS SELECTED. THIS SIGNAL IS USED IN SINGLE FILAMENT SUPPLY GENERATORS ONLY.
“HIGH” (APPROXIMATELY 12 VDC) = FILAMENT FAULT (FILAMENT CURRENT < 2 A). “LOW” (APPROXIMATELY 0 VDC) = NO FILAMENT FAULT.
“HIGH” (APPROXIMATELY 12 VDC) = LARGE FOCUS SELECTED, “LOW” (APPROXIMATELY 0 VDC) SMALL FOCUS SELECTED.
PRIMARY FILAMENT CURRENT AT THESE POINTS MAY BE CONFIRMED USING A CURRENT PROBE ON ONE OF THE OUTPUT LEADS ON THE SMALL OR LARGE PAIR OF OUTPUTS.
THE VOLTAGE AT THESE TEST POINTS WILL BE APPROXIMATELY 1 VDC = 1 AMP OF FILAMENT CURRENT.
THESE TEST POINTS ALLOW MEASUREMENT OF A VOLTAGE PROPORTIONAL TO ANODE CURRENT. THE SCALING IS 0.4 VDC = 100 mA. SHORT EXPOSURE TIMES MUST BE CONSIDERED AND APPRO
MEASUREMENT TECHNIQUES MUST BE USED.
THESE TEST POINTS ARE SCALED 1 VDC = 100 mA OF X-RAY CURRENT.
THESE TEST POINTS ARE SCALED 1 VDC = 2.5 mA OF X-RAY CURRENT (R&F GENERATORS ONLY).
FILAMENT FEEDBACK CURRENT TEST POINT. THIS IS SCALED 1 VDC = 1 AMP OF FILAMENT CURRENT.
PWM OUTPUT. THE WAVEFORM WILL BE AS PER FIGURE 1 FOR LOW AND HIGH FILAMENT CURRENT DEMAND.

Approx 25 usec (40 kHz)


+12 V
LOW FILAMENT
DEMAND

0V
FIGURE 1

+12 V
HIGH FILAMENT
DEMAND

0V

DRAWN DATE
G. SANWALD 12 MAY 2000
CHECKED
S. BLAKE 12 MAY 2000
+24V +24V
1. NOTE: THE PORTION OF THE REMOTE FLUORO EXPOSURE, J12-17 J6-17 EXPOSURE ENABLE COMMAND
REMOTE EXPOSURE, AND REMOTE TOMO SELECT INPUTS U22
1 5 TO J10-35 (PAGE 2)
SHOWN WITHIN THE DASHED OUTLINES IS DETAILED ON 1 5 3
1 5
MD-0763, PAGE 1 U32
U44 2 4 EXPOSURE ENABLE
2 4 +5V
REFER TO PAGE 4 FOR LOGIC LEVELS, LAST IMAGE COMMAND FROM +12V

R39, R57
2 4
HOLD CIRCUIT MD-0767, PAGE 1
NOTES, ETC, REFERENCED BY

RN19B
(U39, C30, ETC.)
HEXAGONAL SYMBOL:
1 5

R92
EXP
U42 U25, U12, U7 SWT
2 4 ADDRESS DECODER, J12-6 J6-6
DATA LATCH, AND DS42 DS41

R82
DRIVER
4
1 5 BUFFER AND ADDRESS TO 2.1 V
REMOTE FLUORO DECODER (U18, U25) CURRENT 1 5
EXPOSURE INPUT U30 SINK
TP4 TP5 TP6
2 U46
2 4
1 J9-8 R70 2 4
SEE NOTE 1
R113

R119
R118
U18, U25 R
J5-6 J4-6 R19 R20 +24V
BUFFER AND J12-5 J6-5
J5-7 J4-7 1 5 ADDRESS
J5-8 J4-8 DECODER RN14D
U15 5
+24V

R24
+5V +5V +5V
R25 2 4 1 5
R120

R121

R102

U38 U25, U12, U7


J5-9 J4-9
U18 2 4 ADDRESS DECODER, J12-7 J6-7 RN14B
DATA LATCH, AND
DRIVER
CPU
4
1 5 U18, U25
U37 BUFFER AND J6-4 RN14E
J12-4
ADDRESS
R18 R72 2 4
DECODER
5

5 1 5 1 5 1
KV CO
DATA BUS U24 U25 U26 +24V
REFER TO
D0..D7
4 2 4 2 4 2
4 3 2 1 JW15 SEE NOTE 1

J13-7 J9-3
MA CO
T R77 REFER T
H J13-9
J9-4
1 5
U43 U25, U12, U7
J13-3 2 4 ADDRESS DECODER, J12-5 J6-5 RN14D
PREP DATA LATCH, AND
DRIVER
REMOTE
4
J13-1 1 5 BUFFER AND ADDRESS
-RAY EXPOSURE DECODER (U18, U25)
INPUT U41
R76 2 4
J13-5
COM

J3-18 J3-19 J3-20


CONSOLE BOARD
+24V

P1-18 4 3 2 1 JW2 SEE NOTE 1 RN14A


J9-24

P1-19 R23
PREP J9-25
1 5
J6-8
X-RAY U8 U25, U12, U7
NSOLE BOARD & P1-20 ADDRESS DECODER,
2 4 J12-8
OARD ASSEMBLY DATA LATCH, AND
ON THIS PAGE IS REMOTE DRIVER GENERATOR CPU BOARD
TOMO BUFFER AND ADDRESS
4
N THE 31 X 42 CM 1 5
SELECT DECODER (U18, U25)
NLY. REFER TO PAGE INPUT DRAWN DATE
U10
23 X 56 CM CONSOLE
R21
G. SANWALD 26 APR 2000 X
AD-ONLY CONSOLE, KEYBOARD ASSEMBLY 2 4 CHECKED
TUBE 1 / TUBE 2 MISMATCH &
THERMOSTAT OPEN SIGNAL
FROM MD-0787

13
J1-4
AUXILIARY BOARD

+5V +5V J8-4 +12V


RN11B

RN11D

R174
KV
EN D19 U33F
+5V R173 J9-9 J3-9
DS30 DS31
14 13 12 RESET COMMAND TO MD-0759, PAGE 1 &
X-RAY MD-0760, PAGE 2
DS26 TP10 J9-7 J3-7
RN11C

GRN RED RN2B “KV ENABLED”


YEL J1-14
DETECTOR CKT ENABLE COMMAND TO MD-0764
6 TO 2.1 V
PREP 1 5 (U11A, RN8, ETC) H.T. TANK
CURRENT 8
SINK U4
DS27 DS28 9 J10-14 RN2A 2 4 RN5E
J1-33
GRN RED
10 +12V
7 TO 2.1 V
D21
CURRENT J10-33 15
SINK U19, U16

RN2F
U27 TP18
J1-15 RN1C “PREP ENABLED”
DATA BUFFER AND J10-15 DETECTOR CKT PREP COMMAND TO MD-0764 & MD-0765
1 5 (U11B, U10C, ETC) J
LATCH DRIVER
U2 D24 D25 RN4B J1
J10-34 RN1D 2 4
J1-34
“GENERATOR READY” 18 R133
DETECTOR CIRCUIT Q12
11 J10-16 (U10A, Q6, D37, ETC)

12 J10-35 +/- 12V/SS FAULT FROM MD-0788,


EXPOSURE ENABLE COMMAND
FROM PAGE 1 PAGE 3 (CONTROL BOARD)

J1-16 RN1H “X-RAY REQUEST” FILAMENT FAULT FROM MD-0760, PAGE 1


DETECTOR CKT
1 5 (U11D, RN7, ETC) STATOR FAULT FROM MD-0764 & MD-0765
U5 HIGH KV / INVERTER FAULT FROM MD-0759, PAGE
J1-35 RN1F 2 4 & HIGH MA FAULT FROM MD-0760, PAGE 2
16
HV / MA FAULT TO MD-0760, PAGE 1
TP12
RN1G “X-RAY REQUEST”
DETECTOR CKT TP14
1 5 (U10D, RN7, ETC) 17
LOGIC “OR / NOR”
U3 CIRCUITS (U10B, U14, DRIVE ENABLE COMMAND TO MD-0759, PAGE 1
Q4, Q13, D91, ETC)
RN1E 2 4

GENERATOR CPU BOARD CONTROL BOARD

DRAWN DATE
G. SANWALD 26 APR 2000 X
CHECKED
S. BLAKE 26 APR 00
+5V

RN7D
+5V
P/S
READY
DS17 DS18
1

R10

R8

R9
GRN RED

19 TO 2.1 V J5-6
CURRENT J5-7
SINK
OPTO-COUPLER “ON” U24 J5-8
= GENERATOR READY
BUFFER 1 5 1 5 1 5
J1-3 J10-3 1 5 U14 U12 U10
FROM
U6 2 4 2 4 2 4
PAGE 2 J1-22 J10-22
2 4 J5-9
U3

BUFFER
DATA BUS
D0..D7
5 1 5 1 5 1
CONTROL BOARD GENERATOR CPU BOARD
U21 U13 U11
4 2 4 2 4 2

DATA BUS
D0..D7

1
TP12 TP13 TB1-1

FOOT
J8-4 TO SWITCH
+5V +5V J4-7 GENERATOR TB1-2
J8-5
J4-8 INTERFACE
J8-3 BOARD
J4-9 (PG 1) TB1-3
R67

R66

PREP
U17
HAND TB1-4
X-RAY
SWITCH
CPU
TB1-5
COM

5 1 5 1 J6-6 J6-8 J6-10


CONSOLE CPU BOARD
U9 U10
DATA BUS
D0..D7 4 2 4 2

P1-18 J2-18 J3-6


J3-3
PREP
PREP P1-19 J2-19 J3-8
J3-1
X-RAY
H
X-RAY
J3-5 P1-20 J2-20 J3-10
COM

J7-3 J7-2 J7-1 CIRCUITS


CONSOLE CPU BOARD
DASHED LI
ON THE
KEYBOARD ASSEMBLY DISPLAY BOARD CONS
P1-3

PREP P1-2

X-RAY
P1-1 DRAWN DATE
G. SANWALD 26 APR 2000 X
CHECKED
KEYBOARD ASSEMBLY CIRCUITS SHOWN WITHIN S. BLAKE 26 APR 00
P1-6 J5-6 J3-7
J4-7

TO
P1-7 J5-7 J2-8 GENERATOR
PREP J4-8 INTERFACE
BOARD
X-RAY (PG 1)
P1-5 J5-5 J2-9
J4-9

KEYPAD ASSEMBLY

J3-3
PREP

HAND J3-1
X-RAY
SWITCH
J3-5
SHOWN WITHIN COM
LINES ARE USED
TOUCH SCREEN
SOLE ONLY. TOUCH SCREEN INTERFACE BOARD

E
REMARKS
NCE
“LOW” (APPROXIMATELY 1 VDC) AT THESE POINTS INDICATES FOOT SWITCH INPUT CLOSED, PREP SWITCH PRESSED, OR X-RAY SWITCH PRESSED RESPECTIVELY. “HIGH” (APPROXIMATELY 24 VDC
OPEN CIRCUIT (I.E. NOT PRESSED) FOOT SWITCH, OR PREP SWITCH, OR X-RAY SWITCH. FOR RAD-ONLY CONSOLE, “LOW” INDICATES PREP SWITCH PRESSED, OR X-RAY SWITCH PRESSED, RESPE
“LOW” (APPROXIMATELY 1 VDC) = AN X-RAY EXPOSURE HAS BEEN REQUESTED VIA ONE OF SEVERAL EXPOSURE INPUTS. “HIGH” (APPROXIMATELY 24 VDC) = NO X-RAY EXPOSURE HAS BEEN REQU
EXPOSURE ENABLE LINE. “LOW” (APPROXIMATELY 0 VDC) INDICATES AN X-RAY EXPOSURE REQUEST, “HIGH” (APPROXIMATELY 5 VDC) = NO X-RAY EXPOSURE HAS BEEN REQUESTED.
THE CATHODE OF THE ASSOCIATED LED IS HELD “LOW” UNDER CPU CONTROL DURING AN X-RAY EXPOSURE REQUEST ONLY. NO MEANINGFUL MEASUREMENTS CAN BE MADE ON THIS LINE AS TH
DATA LINE. THE REQUIRED DATA IS LATCHED BY THE REGISTER CIRCUIT(S) AT THE APPROPRIATE TIME.
THE OUTPUT OF THE ASSOCIATED LED IS LATCHED BY A REGISTER. THIS IS THEN READ BY THE DATA BUS AT THE APPROPRIATE TIME. AS THIS IS A DATA LINE, NO MEANINGFUL MEASUREMENTS CA
MADE AT THIS CONNECTION.
DS30 LIT = KV ENABLE REQUEST SENT. THIS IS NECESSARY TO MAKE AN X-RAY EXPOSURE. DS31 LIT = KV ENABLE NOT REQUESTED.
DS27 LIT = PREP REQUEST SENT. DS28 LIT = PREP NOT REQUESTED.
DS26 LIT = X-RAY EXPOSURE IN PROCESS.
“HIGH” (APPROXIMATELY 5 VDC) = KV ENABLED, “LOW” (APPROXIMATELY 0 VDC) = KV NOT ENABLED.
“HIGH” (APPROXIMATELY 5 VDC) = PREP REQUESTED. “LOW” (APPROXIMATELY 0 VDC) = PREP NOT REQUESTED.
“HIGH” (APPROXIMATELY 5 VDC) = X-RAY REQUESTED. “LOW” (APPROXIMATELY 0 VDC) = X-RAY NOT REQUESTED.
“LOW” = X-RAY EXPOSURE REQUESTED AS PER # 3. THIS LINE MUST BE “LOW” IN ORDER FOR THE X-RAY EXPOSURE LED’S ON THE CONTROL BOARD TO BE ENERGIZED (SEE # 16).
“LOW” = (APPROXIMATELY 0 VDC) = TUBE 1 / TUBE 2 MISMATCH OR THERMOSTAT OPEN FAULT. “HIGH” (APPROXIMATELY 12 VDC) = NO FAULT.
“HIGH” (APPROXIMATELY 12 VDC) = KV ENABLED, “LOW” (APPROXIMATELY 0 VDC) = KV NOT ENABLED.
“HIGH” (APPROXIMATELY 12 VDC) = PREP REQUESTED, “LOW” (APPROXIMATELY 0 VDC) = PREP NOT REQUESTED.
“HIGH” (APPROXIMATELY 12 VDC) = X-RAY REQUESTED, “LOW” (APPROXIMATELY 0 VDC) = X-RAY NOT REQUESTED.
“HIGH” (APPROXIMATELY 5 VDC) = OUTPUT DRIVE ENABLED, “LOW” (APPROXIMATELY 0 VDC) = OUTPUT DRIVE DISABLED.
ALL INPUTS TO THE “GENERATOR READY DETECTOR CIRCUIT” MUST BE AT THE CORRECT LOGIC LEVEL IN ORDER TO BE ABLE TO MAKE AN X-RAY EXPOSURE. THIS MEANS ALL FOUR FAULT INPUTS
MUST BE CLEARED, AND THE KV ENABLE AND PREP COMMANDS MUST BE PRESENT.
DS17 LIT INDICATES GENERATOR READY TO MAKE AN EXPOSURE. THIS REQUIRES THAT ALL CONDITIONS PER # 18 BE SATISFIED. DS18 LIT INDICATES A “GENERATOR READY DETECTOR CIRCUIT” I
NOT SATISFIED TO ENABLE AN X-RAY EXPOSURE.

DRAWN DATE
G. SANWALD 26 APR 2000 X
CHECKED
S. BLAKE 26 APR 00
24 V DC R E T UR N
T2 F5 D3
+ 24 V DC

S3
Q1 L OC K OUT NOR MA L

R 15
24 V DC S UP P LY F OR Q2 D4 K3
S Y S T E M ON/OF F .
S E E MD-0788, P AG E 4
S1 D16
OF F R E F E R TO DC B
K2 P OWE R DIS T R IB
Q3 MD-0788, P AG

R 13
P 1-3 J 3-3 J 5-10 J 4-10 S2
X 42 C M DS 1
ON
K1
ONS OL E 3
ON P 1-2 J 3-2 J 5-11 J 4-11

J UMP E R P OS IT ION:
OF F T O E NE R G IZE K 1 ONLY WHE N
P 1-1 J 3-1 J 5-12 J 4-12 T HE C ONS OLE IS S WIT C HE D ON
J UMP E R J W1 P INS 1-2
T O E NE R G IZE K 1 AT ALL T IME S T HAT
J W1
3 2 1 T HE G E NE R AT OR AC MAINS IS ON
C ONS OLE J UMP E R J W1 P INS 2-3
K E Y B OAR D AS S E MB LY B OAR D (K 1 S WIT C HE S T HE 110 & 220 V AC
S UP P LIE S T O T HE R OOM
INT E R F AC E B OAR D)

P 1-3 J 2-3 J 3-9 J 6-9 J 5-10 J 4-10 1

N P 1-2 J 2-2 J 3-7 J 6-7 J 5-11 J 4-11 2

OF F
P 1-1 J 2-1 J 3-5 J 6-5 J 5-12 J 4-12

C ONS OLE C P U
K E Y B OAR D AS S E MB LY DIS P LAY B OAR D B OAR D

P 1-16 J 7-16 J 8-7 J 4-10

A D-ONL Y
ONS OL E ON P 1-15 J 7-15 J 8-6 J 4-11

OF F
P 1-17 J 7-17 J 8-3 J 4-12

C ONS OLE
K E Y B OAR D AS S E MB LY B OAR D
G E NE R AT OR INT E R FAC E B OAR D

SCREEN US E DR AWING DC B US & P OWE R DIS T R IB UT ION, MD-0788, IN C ONJ UNC T ION WIT H T HIS DOC UME NT
ONS OL E P 1-2 J 5-2 J 2-10 J 4-10

ON P 1-3 J 5-3 J 2-11 J 4-11

OF F
P 1-4 J 5-4 J 2-12 J 4-12 DR AWN DAT E
G . S ANWALD 02 J UN 2000
T OUC H S C R E E N C HE C K E D_________ S
_________
INT E R F AC E
K E Y PAD AS S E MB LY B OAR D DE S .\MF G .\AUT H.
NOTE
REMARKS
REFERENCE
MOMENTARILY PRESSING ON CONNECTS THIS LINE TO “24 VDC RETURN”. THIS LATCHES RELAY DRIVERS ON THE GENERATOR INTERFACE BOARD,
1 ENERGIZING K2 AND K3, AND POSSIBLY K1 (DEPENDING ON JW1 SETTING). SEE NOTE ADJACENT TO JW1 ON THIS DOCUMENT.
MOMENTARILY PRESSING OFF CONNECTS THIS LINE TO “24 VDC RETURN”. THIS UNLATCHES RELAY DRIVERS ON THE GENERATOR INTERFACE BOARD,
2 DE-ENERGIZING K2 AND K3, AND POSSIBLY K1 (DEPENDING ON JW1 SETTING).
DS1 LIT INDICATES THE PRESENCE OF THE 24 VDC SUPPLY SHOWN. THIS 24 VDC SUPPLY WILL BE PRESENT IF THE GENERATOR IS CONNECTED TO A
3
LIVE AC MAINS SUPPLY.

DRAWN DATE
G. SANWALD 02 JUN 2000
CHECKED_________ _________
NOTE *
TB1-5 J2-15 J9-15
E 4 3 2 1 JW7
ER TB1-4 J2-16 J9-16
T +24V 1 5
NOTE * U7, U12, U18,
R53 U21
TB2-5 J2-13 J9-13 U19, U25
+24V R54
Y 4 3 2 1 JW10 2 4
NOTE *
TS TB2-4 J2-14 J9-14
4 3 2 1 JW9 1 5
TB2-7 J2-11 J9-11 R55 U31
1 5 R56
OR 2 4
K TB2-6 J2-12 J9-12 R66
U29 +24V
R67 2 4 NOTE *
TB3-5 J2-24 J9-24
4 3 2 1 JW2
MO SEE
TB3-4 J2-25 J9-25 MD-0761 J12-1 J6-1
D0
R23
TB3-7 J2-22 J9-22 U8

U10 J12-2 J6-2


RE TB3-6 J2-23 J9-23 D1
R21
+24V
TB4-4 J2-21 J9-21
1 5
OR U14 +24V
D2 J12-3 J6-3
CK TB4-5 +24V NOTE *
R29 R38 2 4 1 5 JW3
TB4-6 J2-20 J9-20 U13 4 3 2 1

D3 J12-4 J6-4
AL R34 R36 +24V 1 5
2 4
H2 TB4-7
R32 BUFFER, DRIVER
U9
T2 FROM MD-0787 R22 AND ADDRESS
TB4-8 J2-19 J9-19 U16 2 4
DECODER CIRCUITS D4 J12-5 J6-5
R33 R37
AL
H1 TB4-9
T1 FROM MD-0787
TB5-12 J2-17 J9-17 D5 J12-6 J6-6

OT +24V
TB5-11 J2-18 J9-18 NOTE *

+24V D6 J12-7 J6-7


TB6-4 J2-9 J9-9 4 3 2 1 JW6
NOTE *
R35
1 5
TY TB6-3 J2-10 J9-10 4 3 2 1 JW8
U20 J12-8 J6-8
R68 D7
+24V 1 5 R52 2 4
TB6-5 J2-8 J9-8
** U27
RO U30, U42,
TB6-6 J2-7 J9-7 R71 R69 2 4
U44 DATA BUS
R70 DO..D7
TB6-8 J2-5 J9-5

TE
P TB6-7 J2-6 J9-6 +24V
NOTE *
TB6-10 J2-3 J9-3
4 3 2 1 JW14
E
+24V
RE TB6-9 J2-4 J9-4 R75
NOTE * 1 5
U28
4 3 2 1 JW15
TP14 J2-1 J9-1 R74 2 4
R77 **
J2-2 J9-2
U41,
R76 U43

ROOM INTERFACE BOARD GENERATOR INTERFACE BOARD GENERATOR CPU BOARD

THIS PAGE SHOWS THE ROOM INTERFACE INPUTS. ROOM INTERFACE OUTPUTS ARE
SHOWN ON PAGE 2
* * DRAWN DATE
24 VDC EXTERNAL INPUT POSITION DRY CONTACT INPUT POSITION G. SANWALD 13 APR 2000
FOR JW2, JW3, JW6, JW7, JW8, JW9, FOR JW2, JW3, JW6, JW7, JW8, JW9, CHECKED
** ADDITIONAL CIRCUITS ARE USED IN THE AREAS INDICATED **. THESE CIRCUITS ARE NOT JW10, JW14, JW15 SHOWN. JW10, JW14, JW15 SHOWN. JUMPER S. BLAKE 14 APR 2000
MD-0788, PAGE 4, ON +24V +24V
GENERATOR INTERFACE BOARD
C2
J9-40 J2-40 TB1-2
U6, U7, U11, U12 R2 JW12
U24, U25, U34 J9-39 J2-39 K1 TB1-1

DRIVE 1 J9-30 J2-30


C1
K1 TB1-11
JW1 1 2 3 4 5 6 7 8 R1 JW9
DRY * LIVE * K2 TB1-12
DRIVE 2 J9-29 J2-29
K2
TB11
JW2 1 2 3 4 5 6 7 8
J9-28 J2-28 1 DRY * LIVE *
DRIVE 3 K6
K3 2
J6-1 J12-1 D0 K3
3 C3
K4
TB2-2
J9-27 J2-27 4 R3 JW11
DRIVE 4 K1
5 K3 TB2-1
J6-2 J12-2 K4 K2
D1

C4
DRIVE 5 J9-34 J2-34 220 VAC TB2-11
JW3 1 2 3 4 5 6 7 8 R4 JW10
J6-3 J12-3 K5
D2 TB10 DRY * LIVE * K4 TB2-12
1
DRIVE 6 J9-32 J2-32 2 TB3-1

J6-4 J12-4 K6 3 K5 TB3-2


D3 JW4 1 2 3 4 5 6 7 8
ADDRESS DECODERS, 4 DRY * LIVE *
BUFFER, REGISTER, DRIVE 7 J9-31 J2-31 5
TB3-11

J6-5
AND DRIVER K7 TB3-12
J12-5 D4 CIRCUITS C6 JW14
110 VAC
R6
DRIVE 8 J9-35 J2-35 C5 TB4-11
TB9 K6
J6-6 J12-6 K8
D5 1 K8 TB4-12

R5
2 JW13
DRIVE 9 J9-36 J2-36
3 JW5 1 2 3 4 5 6 7 8 TB4-1
J6-7 J12-7 K9
D6 4 DRY * LIVE *
K7 TB4-3
5
DRIVE 10 J9-37 J2-37
TB4-2
K10 NOTE THE FOLLOWING IF USING JW1, JW2,
J6-8 J12-8 +24V
D7 24 VDC JW3, JW4, OR JW5 IN THE LIVE CONTACT
POSITION: TB5-2
TB8
J9-38 J2-38 A JUMPER WIRE MUST BE CONNECTED TO K9 TB5-4
DRIVE 11 1 JW6 1 2 3 4
TB11 PIN 1, 2, 3, 4 OR 5 AS APPROPRIATE
K11 TB5-3
2 FROM TB8, TB9, OR TB10 IN ORDER TO
SUPPLY 24 VDC, 110 VAC, OR 220 VAC DRY **
3 FROM THE SELECTED OUTPUT K10 TB5-7
LIVE 24 VDC **
DRIVE 12 J9-33 J2-33
4 TB5-6
K12
5
TB5-5

DRIVE 13 J9-26 J2-26


TB7 K12 TB5-8
K13
DRIVE 1 TO 1 K11 TB5-10
DRIVE 13 = “LOW” +24V
ENERGIZES 2 TB5-9
THE RELAYS 3 K13
JW7 1 2 3 4 TB5-1
4
+24V
5 DRY **
TB6-1
LIVE 24 VDC **
TB6-2
JW8 1 2 3 4
TB6-11
DRY **
TB6-12
LIVE 24 VDC **
TOR CPU BOARD GENERATOR INTERFACE BOARD ROOM INTERFACE BOARD

THIS PAGE SHOWS THE ROOM INTERFACE * LIVE CONTACT LIVE CONTACT ** LIVE CONTACT 24VDC LIVE CONTACT 24VDC
DRAWN DATE
OUTPUTS. ROOM INTERFACE INPUTS ARE G. SANWALD 13 APR 2000
SHOWN ON PAGE 1 CHECKED
DRY CONTACT DRY CONTACT S. BLAKE 14 APR 2000
TO PAGE 2 FOR LOGIC LEVELS,
ETC, REFERENCED BY
ONAL SYMBOL:

+12V TUBE
J3-9 SHIF
R1

J1-1
+12V K2
C3
D
J3-3 MAIN

R121
J1-20 RN4E
K4 COM
R138 J6-10 J5-10
2 +12V
Q18
D7
R29 J4-9 J4-9 J3-8 J2-8
1
Q3

R30
K1 TUBE
J3-7 SHIF
STATOR FAULT TO GENERATOR
READY DETECTOR CIRCUIT ON K3
CONTROL BOARD, SEE MD-0761
TP1

J3-5 MAIN

J3-1 COM
PREP COMMAND J6-8 J5-8
3
FROM MD-0761, COMMON FROM J1-4. REFER
PAGE 2 F3
TO LOW SPEED STARTER
BOARD ON MD-0788, PAGE 1

JUMPER POSITION:
INDICO 100 GENERATORS
JUMPER “1.5S” FOR 1.5 SEC 120 / 240 VAC FROM J1-1. REFER Q2
F1
BOOST, NO JUMPERS FOR TO LOW SPEED STARTER
2.5 SEC BOOST. REFER TO BOARD ON MD-0788, PAGE 1
4 TP3 +12V
CH. 2 OF SERVICE MANUAL.
DO NOT USE JUMPER ZERO
POSITION “.15S”
R36

CROSS

R5
TP3 CIRCUIT
JW1 U2
BOOST AND J4-11 J4-11 J3-7 J2-7
.15S RUN LOGIC
CIRCUIT
1.5S (U1, U10, U18
Q2, Q12, ETC.) 52 / 73 / 94 VAC FROM J1-3. Q1
F2
REFER TO LOW SPEED STARTER
5 BOARD ON MD-0788, PAGE 1
TP4 +12V
ZERO
TUBE 1 / TUBE 2 MISMATCH &
R35

CROSS

R1
THERMOSTAT OPEN SIGNAL TP2 U1 CIRCUIT
FROM MD-0787
J4-12 J4-12 J3-6 J2-6
12 VDC / SOFT START
FAULT SIGNAL +12V
FROM MD-0788,
PAGE 3
+12V
8 D1
7 K1 +12V
D18
J4-6 J4-6 J3-10 J2-10
R45

ENABLE COMMAND 6 J8-4 J1-4


D15 D2
FROM MD-0761, Q15 TUBE SELECT SIGNAL FROM J2-9. REFER TO LOW K4
PAGE 2 D17 J2-9 SPEED STARTER BOARD ON MD-0788, PAGE 1
R46

POWER INPUT BOARD LOW SPEED STARTER BOARD


CONTROL BOARD AUXILIARY BOARD

DRAWN DATE
G. SANWALD 10 MAR 2000
CHECKED________ ________
+5V

RN7A
ROTOR
DS20 DS21

GRN RED
TO 2.1 V
9 OPTO-COUPLER
CURRENT
U24 “ON” = NO FAULT
SINK
J10-1 J1-1
BUFFER
5 1
U5
FROM
PAGE 1
4 2 J10-20 J1-20

BUS
D7

GENERATOR CPU BOARD CONTROL BOARD

E
REMARKS
NCE
“HIGH” (APPROXIMATELY 6-11 VDC) = NO STATOR FAULT, “LOW” (<APPROXIMATELY 2 VDC) = STATOR FAULT (LOW OR NO STATOR CURRENT).
“LOW” (APPROXIMATELY 0 VDC) = NO STATOR FAULT, “HIGH” (APPROXIMATELY 12 VDC) = STATOR FAULT (LOW OR NO STATOR CURRENT).
“HIGH” (APPROXIMATELY 10 VDC) = PREP REQUESTED, “LOW” (APPROXIMATELY 1 VDC) = PREP NOT REQUESTED.
“LOW” (APPROXIMATELY 0 VDC) = BOOST REQUESTED, “HIGH” (APPROXIMATELY 12 VDC) = BOOST NOT REQUESTED (BOOST REQUESTED FOR APPROXIMATELY 1.5 SEC AFTER PREP INITIATED).
“LOW” (APPROXIMATELY 0 VDC) = RUN REQUESTED, “HIGH” (APPROXIMATELY 12 VDC) = RUN NOT REQUESTED (RUN REQUESTED AFTER BOOST COMPLETE, AND FOR DURATION THAT PREP IS PRE
“HIGH” (APPROXIMATELY 12 VDC) = LOW SPEED STARTER ENABLED, “LOW” (APPROXIMATELY 0 VDC) = STARTER DISABLED (SEE # 7).
THIS POINT MUST BE “HIGH” (AS PER # 6) TO ENABLE THE LOW SPEED STARTER. THIS REQUIRES THE ENABLE COMMAND TO BE PRESENT (”HIGH”), AND THE TUBE 1 /TUBE 2 MISMATCH &THERMO
OPEN SIGNAL TO BE “HIGH”. IF THE 12 VDC / SOFT START FAULT SIGNAL IS LOW (INDICATING A FAULT), J1-4 WILL NOT BE PULLED LOW DUE TO THE DIODE SHOWN CONNECTED TO THIS PIN ON PAG
“LOW” (APPROXIMATELY 0 VDC) ENERGIZES K1 ON THE LOW SPEED STARTER BOARD, ENABLING THE STARTER. “HIGH” (APPROXIMATELY 12 VDC) DE-ENERGIZES K1 ON THE LOW SPEED STARTER
AS PER # 6 AND 7, NO ENABLE COMMAND, OR PRESENCE OF A TUBE 1 / TUBE 2 MISMATCH & THERMOSTAT OPEN FAULT, OR A 12 VDC / SOFT START FAULT WILL INHIBIT LOW SPEED STARTER OPE
DS20 LIT INDICATES NORMAL STATOR CURRENTS. DS 21 LIT INDICATES STATOR FAULT, OR LOW SPEED STARTER IS IN STANDBY MODE.

DRAWN DATE
G. SANWALD 10 MAR 2000
CHECKED________ ________
CS1, U10, U11

+5V SW1 * SW2 * INVERTER


+5V FAULT
DETECTOR
RN7G
DS1
560 / 650 VDC (+)
INVERTER
FAULT
DS8 DS7

R24
HS LS 5
TO 2.1 V U17, U18
1 CURRENT U19, U22, U24
SINK U19, U16 R40
U27 IGBT IGBT
J10-2 J1-2 2 J4-6 J1-6 DRIVER SWITCH SWITCH
DATA BUFFER AND 1 5
LATCH DRIVER CIRCUIT AND (Q2) (Q4)
J10-21 J1-21 J4-8 J1-8 U12 FAULT
CURRENT
2 4
LATCH
(U1-U10, IGBT IGBT
+12V HIGH SPEED T1-T4, ETC). SWITCH SWITCH
SELECT (Q1) (Q3)

PREP COMMAND K4
FROM MD-0761

R96
+12V
D47
6
R41
Q7 560 / 650 VDC (-)
J4-2 J1-2 1 5

R94 J4-4 J1-4 U13


2 4
3 DUAL SPEED T
PREP STARTER CPU, K1-A TB2-3 S
BUFFERS, K5
CONTACTOR +12V INITIATED
CLOSED DRIVERS
SIGNAL FROM R42
K2-A
MD-0788, PAGE 3 J4-14 J1-14 K1 D47
1 5
U14 Q5
J4-16 J1-16
TB2-2

R31
2 4
K6 +12V
4 K2 K5
R32 TB2-1 C
+5V TUBE 2 C22
TUBE 1/TUBE 2 SELECT
SELECT SIGNAL
RN7A

FROM MD-0788, K3 HIGH SPEED


PAGE 3 PHASE SHIFT
ROTOR CAPACITOR
K6 K1-B
DS20 DS21
+12V TU
GRN RED K4
K2-B TB3-3 S
TO 2.1 V
8 OPTO-COUPLER
R1

CURRENT
U24 “ON” = NO FAULT
SINK
J10-1 J1-1
BUFFER
5 1 +12V
K3
U5 TB3-2
7
R121

J4-10 J1-10
4 2 J10-20 J1-20 RN4E LOW SPEED
TB3-1 C
PHASE SHIFT
R138 CAPACITOR
Q18

STATOR FAULT TO
GENERATOR READY
DETECTOR CIRCUIT
ON CONTROL BOARD,
SEE MD-0761

GENERATOR CPU BOARD CONTROL BOARD DUAL SPEED STARTER BOARD

* REFER TO CHAPTER 2 OF SERVICE MANUAL FOR THE


PROCEDURE TO SET DIP SWITCHES SW1 AND SW2 DRAWN DATE
G. SANWALD 30 MAR 2000
CHECKED
STEVE BLAKE 30 MAR 2000
E
REMARKS
NCE
DS8 LIT INDICATES HIGH SPEED SELECTED, DS7 LIT INDICATES LOW SPEED SELECTED.
“HIGH” (APPROXIMATELY 5 VDC) = HIGH SPEED SELECTED, “LOW” (APPROXIMATELY 0 VDC) = LOW SPEED SELECTED.
“LOW” (APPROXIMATELY 7 VDC) = CONTACTOR CLOSED AND PREP REQUESTED. THIS INITIATES THE BOOST CYCLE. “HIGH” (APPROXIMATELY 12 VDC) = BOOST NOT REQUESTED (PREP COMMAND N
RECEIVED, OR CONTACTOR IS NOT CLOSED).
“LOW” (APPROXIMATELY 0 VDC) = TUBE 2 SELECTED, “HIGH” (APPROXIMATELY 12 VDC) = TUBE 2 DESELECTED. THIS CONDITION DEFAULTS TO TUBE 1.
DS1 LIT INDICATES AN INVERTER CURRENT FAULT. POSSIBLE CAUSES INCLUDE INCORRECT DIP SWITCH SETTINGS FOR THE TUBE IN USE (SEE ** ON PAGE 1), INCORRECT STATOR IMPEDANCE, OR
DEFECTIVE STATOR CABLE.
K4 OPEN CIRCUITS THE STATOR COMMON LEAD AT ALL TIMES THAT THE DUAL SPEED STARTER IS IN STANDBY MODE.
“LOW” (APPROXIMATELY 0 VDC) = NO STATOR FAULT, “HIGH” (APPROXIMATELY 12 VDC) = STATOR FAULT (LOW OR NO STATOR CURRENT).
DS20 LIT INDICATES NORMAL STATOR CURRENTS. DS21 LIT INDICATES STATOR FAULT, OR DUAL SPEED STARTER IS IN STANDBY MODE.

DRAWN DATE
G. SANWALD 30 MAR 2000
CHECKED
STEVE BLAKE 30 MAR 2000
J1-1 J2-1
J1-2 J2-2
J1-3 J2-3
J1-4 J2-4
+5V +5V
J1-5 J2-5
J1-6 J2-6
DS15 DS19 J1-7 J2-7
LS1 J1-8 J2-8 LED
TXD RXD
J1-9 J2-9 DISPLAYS
(7 SEGMENT
R43

R46

J1-10 J2-10 DISPLAYS &


DATA LATCHES DRIVERS
J1-11 J2-11 (U6-U9) (U1-U4, U10) STATUS LEDs)
U20 U11 U7 DS1-DS23
J1-12 J2-12
RN3E J11-3 P1-3 MICRO- J1-13 J2-13
RN3F J11-7 P1-7 CONTROLLER
RS-232 RS-232 J1-14 J2-14
UART TRANSMITTER / RN3G J11-2 P1-2 RECEIVER / (CPU, EPROM **,
RECEIVER RN3H DRIVER ADDRESS DECODERS
J11-8 P1-8 & LOGIC CIRCUITS)
U1, U2, U3, U4
U5
** U3 IS THE EPROM.
J1-1 P1-1
BUFFER J1-2 P1-2
DATA & ADDRESS
BUS J1-3 P1-3
J1-4 P1-4
J1-5 P1-5
J1-6 P1-6 FRONT PA
J1-7 P1-7 KEYBOA
SWITCH
J1-8 P1-8
J1-9 P1-9
J1-10 P1-10

GENERATOR CPU BOARD REMOTE FLUORO CONTROL BOARD REMOTE FLUORO DISPLAY BOARD KEYBOARD ASSEMB

REMOTE FLUORO CONTROL UNIT

OUBLESHOOTING CAN BE PERFORMED ON THE REMOTE FLUORO CONTROL ASSEMBLY IN THE FIELD. THE DC RAILS CAN BE CHECKED (REFER TO MD-0788),
D AND RXD LEDs ON THE GENERATOR CPU BOARD MAY BE OBSERVED (THESE WILL FLASH ON AND OFF TO INDICATE DATA FLOW). MEANINGFUL MEASUREMENTS
MADE ON COMMUNICATIONS, DATA, AND CONTROL LINES.

DRAWN DATE
G. SANWALD 02 JUN 2000 R
CHECKED _________ _________
+24V +15V +5V

J13-11

J13-13

J13-17

J13-15

-15V

D0 RN14H J6-1 J12-1 RN4A RN3A J13-1


D1 RN14G J6-2 J12-2 RN4B RN3B J13-2
D2 RN14F J6-3 J12-3 RN4C RN3C J13-3
D3 RN14E J6-4 J12-4 RN4D RN3D J13-4
D4 RN14D J6-5 J12-5 RN4E RN3E J13-5
D5 RN14C J6-6 J12-6 RN4F RN3F J13-6
D6 RN14B J6-7 J12-7 RN4G RN3G J13-7
D7 RN14A J6-8 J12-8 RN4H RN3H J13-8
J6-9 J12-9

WRITE ENABLE J6-11 J12-11 J13-10


READ ENABLE J6-13 J12-13 J13-12
RESET J6-20 J12-20 J13-16 CONTINUED
ADDRESS LATCH ENABLE R91 J6-15 J12-15 R115 R84 J13-18 ON PAGES
J7-20 J11-20 J13-19 2 TO 6
HV ON SIGNAL FROM J13-14
EXPOSURE ENABLE COMMAND
MD-0759, PAGE 1
TO MD-0761, PAGE 1

“DIGITAL IMAGING” ABS J13-20


+5V TO MD-0758
RN19D

J13-22

6 4
5 DS40
SYNC 3
U45B
3 1 R97 J7-15 J11-15 2
2 JW22
5 1 1
U45A
U28 3 U51
JUMPER POSITION:
2 4 2 INTERNAL (LINE SYNC)
CPU JW3 LINE SYNC FROM JUMPER PINS 1-2
1 MD-0788, PAGE 4 EXTERNAL (DIGITAL IMAGING SYNC)
JUMPER PINS 2-3
JUMPER POSITION:
INVERTED SYNC J13-9
JUMPER PINS 1-2
NON-INVERTED SYNC J13-21
JUMPER PINS 2-3
DATA, ADDRESS, J13-23
AND CONTROL BUS

GENERATOR CPU BOARD GENERATOR INTERFACE BOARD

DRAWN DATE
G. SANWALD 16 MAY 2000
CHECKED
KVR 17 MAY 2000
+5V +15V +24V

J1-11

J1-13

J1-17

J1-15

TP1 TP2
-15V U7
+24V
R2 J2-20
J1-20
MUX R3 J2-21

R11
+24V
J1-14
1 5

R1
U16
3 +24V +24V +24V +24V +24V +24V +24V
2 4
5 1
2
U3B JW1 U10 F1 J2-1

R10

R12

R13

R14

R15

R16
4 6 1
J1-19 5 4 2 +24V
DS4 DS6 DS7 DS8 DS9 DS10

R17
EXON PFL HCF PREP GEN TOMO
J1-1 U4 U6 READY
J1-2 J2-7
1 5
J1-3
J1-4 J2-3 U14

J1-5 DATA DRIVER J2-4 2 4


LATCH J2-5
J1-6 ADDRESS DECODER
J1-7 CIRCUITS J2-6
(U1, U2, U3A, U6A) J2-22
J1-8
J1-10
J1-12
+24V
J1-16 +24V
J1-18 U8

R6

R7
J2-9
BUFFER 5 1 DS1
J1-9 U13
OFL
J1-21 4 2 +24V
+24V
J1-23

R5
U9 SW1

R8
J2-23
5 1 DS2
BUFFER U12
STOP J2-2
4 2 EXP. +24V
+24V J2-10

R4
J2-12

R9
5 1 DS3
U11
O.EXP
4 2
J2-11

DIGITAL I/O BOARD

THIS SHEET APPLIES TO DIGITAL I/O BOARD ASSEMBLY 733752.


DRAWN DATE
G. SANWALD 16 MAY 2000
CHECKED
KVR 17 MAY 2000
+24VR +24VR
+5V +15V +24V +24VR
J3-25
J1-11 J3-27

J1-13 J3-29
D6 J3-31
J1-17 F1
J3-33
J1-15 D5 J3-35
R10
Q1

-15V

R9
D3 U17
12 U10D 11
J1-19 MONOSTABLE
13 TIMER
D4
U14 U16
J1-1
J1-2
J1-3
J1-4 DATA
DRIVER
J1-5 LATCH
J1-6 ADDRESS DECODER +24V +24VR
J1-7 CIRCUITS
(U1, U2, U9, U10C)
J1-8

R15
J1-10
U13 U15 R13 J3-34
J1-12 Q2
J1-16 J3-32

J1-18 J3-30
D1 J3-28
DATA DRIVER J3-26
LATCH
J3-36

+24V +24VR
+24VR +24VR +24VR
U12

R14
R12
J1-9 Q3
BUFFER 5 1 R1 5 1 R2 5 1 R3
J3-47
J1-21
U3 U4 U5
J1-23 D2
4 2 4 2 4 2 J3-41
J3-39
U11 SW1
J3-37
J3-38
BUFFER J3-40
J3-42
J3-44
5 1 R4 5 1 R5 5 1 R6 J3-46
U6 U7 U8
4 2 4 2 4 2
+24VR
J3-45
J3-43
R16

J1-22 J3-48

J1-20

DIGITAL I/O BOARD

THIS SHEET APPLIES TO DIGITAL I/O BOARD ASSEMBLY 733947, 735921.


DRAWN DATE
G. SANWALD 16 MAY 2000
CHECKED
KVR 17 MAY 2000
+24V

F1 J2-14
+5V +15V +24V +5V(A)

J1-11 U12
J1-13 +5 V J2-21
REGULATOR
J1-17

+15V J2-8
J1-1
1 5
J1-2
U7 +15V J2-22
J1-3
J1-4 U4 U6 2 4 1 5
DS4
J1-5 U10
R2
J1-6 ADDRESS DECODER 2 4
J1-7 CIRCUITS DATA DS3
(U1, U2, U3A, U5A) DRIVER
LATCH R1 J2-11
J1-8
J1-10 +24V J2-13
J1-12
J1-16

R9
J1-18

DS2 J2-15

R8
J1-14
J2-4

R6
5 1
U16
J2-5

R7
4 2

U8 5 1 J2-6
U14
J1-9
4 2 J2-16
J1-21
BUFFER
J1-23 5 1 J2-18
U15
+5V(A) 4 2 J2-17
U9 SW1
5 1
J2-19
U11
+24V
BUFFER 4 2 DS5
5 1
R3
U13 J2-9
4 2 DS1 J2-12
R4 R5

DIGITAL I/O BOARD

THIS SHEET APPLIES TO DIGITAL I/O BOARD ASSEMBLY 735406.


DRAWN DATE
G. SANWALD 16 MAY 2000
CHECKED
KVR 17 MAY 2000
+24V

F1 J2-13

+5V +15V +24V J2-7


J2-8
J1-11 J2-9
J1-13 J2-12

J1-17 J2-5

J2-6

+15V J2-20

1 5 +15V J2-24

J1-1 U10
1 5 +15V J2-22
J1-2 U6 2 4
DS3 U7
J1-3 U4 1 5 +15V J2-21
R1 2 4
J1-4 DS4 U13
1 5 +15V J2-23
J1-5 R2 2 4
J1-6 DATA DS7 U14
ADDRESS DECODER DRIVER 1 5
J1-7 CIRCUITS LATCH R7 2 4
(U1, U2, U3A, U5A) DS8 U15
J1-8
R8 2 4
J1-10 DS9 J2-1
J1-12 R9
J1-16 J2-2
12 11
J1-18 9
8 13
10
U3D J2-3
U3C
J1-19
J2-4

J2-11

U8 J2-15

J1-9
J2-16
J1-21
BUFFER
J1-23
J2-17
J

J2-18
U9 SW1
+24V
J2-19
BUFFER 5 1
J
U11
+24V
4 2 DS5 J2-10
5 1 R3 R4
U12
4 2 DS6 J2-25
R5 R6

DIGITAL I/O BOARD

THIS SHEET APPLIES TO DIGITAL I/O BOARD ASSEMBLY 736153


DRAWN DATE
G. SANWALD 16 MAY 2000
CHECKED
KVR 17 MAY 2000
+5V +15V +24V U1
U12
J2-8
J1-11
* DS38
J2-21
J1-13 * DS40
J2-9 +24V
DRIVER
J1-17 * DS41
J2-22 J2-13
J1-15 * DS43
J2-23 J2-1
* DS45 U9
J3-8 J2-2

-15V U11 * DS16


J3-27 J2-3
J2-17 * DS18
J3-9 J2-4
J2-4
* DS20
J3-28 J2-5
J2-16 DRIVER
* DS21
J3-10 J2-6
J2-3
DRIVER J2-15
* DS22
J3-29 J2-7
J1-1 * DS23
J2-2 J3-31 J2-8
J1-2
J2-14 * DS24 J2-9
J1-3
J2-1
J1-4 J2-10
U3
J1-5 DS27 DS29 DS31 DS33 DS35 DS36 DS37 DS39 J3-23 J2-11
J1-6 J3-4 J2-12
J1-7 * * * * * * * *
CPLD J3-22 J2-14
J1-8 U10 J3-3
J2-5 J2-15
J1-10 DRIVER J3-21
* DS25 J2-18 J2-16
J1-12 J3-2
* DS26 J2-6 J2-17
J1-18 J3-20
J1-19 * DS28 J2-19 J3-1 J2-18
DRIVER
J1-22 * DS30 J2-7 J2-19
DS4 DS6 DS8 DS11 DS13 DS14 DS17 DS19
* DS32 J2-20 J2-20
* DS34 * * * * * * * * J2-21
+24V +24V
U2 J2-22
U17 J3-5
J2-23
* DS1

R77
J3-24
J2-24
R78 * DS3 J3-6
Q1 J2-25
DRIVER DS46 DRIVER * DS5 J3-25
R72
* DS7 J3-7
D3 * DS10 J3-26
* DS12

J2
-1

+15V
1
10

32

30

33
-2

-1
U

U
-

-
J2

J3

J3

J2

J2

J3
1

1
D1
J1-20 R63 DS2 DS9 DS44 DS42 DS15
5 1 5 1 5 1 5 1 5 1
D2 U4 U6 U15 U13 U8
4 2 4 2 4 2 4 2 4 2 R30
-15V
J1-14

J1-9 5 1 5 1 5 1 5 1
J5-1
J1-21 U5 U7 U16 U14 24V FROM
ROOM INTERFACE J5-3
J1-23 4 2 R17 4 2 R25 4 2 R69 4 2 R68

DIGITAL I/O BOARD

THIS SHEET APPLIES TO DIGITAL I/O BOARD ASSEMBLY 736894


DRAWN DATE
* DUE TO SPACE RESTRICTIONS, SERIES RESISTORS ARE NOT SHOWN FOR THE INDICATED LED’S G. SANWALD 16 MAY 2000
CHECKED
KVR 17 MAY 2000
NOTE
REMARKS
REFERENCE
D36 LIT INDICATES RAD OR PULS
REFER TO MD-0759 1 MODE. D36 NOT LIT INDICATES C

K1
PAGE 2 FLUORO MODE.
+12V
“LOW” (APPROXIMATELY 0 VDC) =
RESONANT BOARD ENERGIZED I

R44
+12V
2 FLUORO MODE. “HIGH” (APPROX
D36
= K1 ON RESONANT BOARD DE-E
J2-1
THESE CIRCUITS USED CONTINUOUS FLUORO MODE.
J2-1
RAD ON R&F GENERATORS
1 MODE “LOW” (APPROXIMATELY 0 VDC) =
J2-2
J2-2 K1 ONLY
M J1-5 (AUXILIARY R79 MODE SELECT BOARD ENERGIZE
RD), SEE MD-0788, Q5
PAGE 3 2 LOW POWER RAD MODE (< 20 kW
3
R47

(APPROXIMATELY 12 VDC) = K1 O
SELECT BOARD DE-ENERGIZED I
RAD MODE (> 20kW APPROX).
RESONANT BOARD

+12V
D38
J10-1 J3-1
THE POWER MODE SELECT
K1
D1 BOARD IS USED ON 65 / 80 kW
D44 J10-2 J3-2
M J1-3 (AUXILIARY R69 GENERATORS WITH THREE
RD) SEE MD-0788, Q4
PAGE 3 3 INVERTER BOARDS ONLY
R66

AUXILIARY BOARD
ENERGIZING K1
DISABLES DRIVE
TO INVERTER
BOARD No. 3

J12-1 J1-1 K1
J4-1 J1-1
J12-2 J1-2
INVERTER DRIVE SIGNAL J4-2 J1-2
J12-3 J1-3 INVERTER DRIVE SIGNAL
FROM MD-0759 J4-3 J1-3
J12-4 J1-4 TO MD-0759
J4-4 J1-4

CONTROL BOARD POWER MODE SELECT BOARD INVERTER BOARD

DRAWN DATE
G. SANWALD 21 MAR 2000 R
CHECKED________ ________ PO
+12V

R39
ON OFF JUMPER POSITION:
1 2 3 R&F GENERATORS (WITH THERMAL SWITCH)
+12V
JW4 JUMPER JW4 PINS 1-2 (ON)
RAD GENERATORS (NO THERMAL SWITCH) D42
THERMAL
JUMPER JW4 PINS 2-3 (OFF)

R41
4 CUTOFF
OPEN
J2-4 R40
Q10

R43
J2-3
+12V
D26
THERMAL SWITCH ON
INVERTER HEATSINK
TUBE 1 / TUBE 2 MISMATCH &

R6
(R&F UNITS ONLY) 5
THERMOSTAT OPEN SIGNAL TO
+12V MD-0764 AND MD-0761, PAGE 2
TUBE 1 / TUBE 2
TELLBACK LOGIC R7
CIRCUIT Q8
1 5
(U9, U10, R84) +5V

R8
U7

RN7H
2 4
1 / TUBE 2
ID DRIVE
TS SEE
INVERTER BOARD
TUBE 1 / TUBE 2 SELECT DS5
, PAGE 1 1 5
SIGNAL FROM MD-0788,
U8 PAGE 3 TUBE
TUBE 1 / TUBE 2 SELECT 2
2 4 COMMAND FROM MD-0788,
TUBE 1 / TUBE 2 PAGE 1 U35
RELAY CONTACTS 3
(SHOWN IN TUBE D39 +12V DECODER/
J5-1 J11-1 J4-20 J4-20
1 POSITION) DEMULTIPLEXER
R28 J1-2 J8-2 J2-5 J3-5 1 5
TUBE 2
J5-2 J11-2 J4-19 J4-19 R38 SELECTED
U3
J1-1 J8-1 J2-13 J3-13
1 2 4
2
OPTO COUPLER
“ON” = TUBE 2 SELECTED

POWER INPUT
H.T. TANK BOARD AUXILIARY BOARD CONTROL BOARD GENERATOR CPU BOARD

MD-0763 (ROOM INTERFACE) FOR INTERLOCKS ACCESSED VIA THE ROOM INTERFACE BOARD
TUBE 1
STATOR
TERMINAL
BLOCK
J5-1 TUBE 1 TH
ON MD
THERMAL
TE SWITCH
REMARKS J5-2
ENCE
“LOW” (APPROXIMATELY 0 VDC) = TUBE 2 SELECTED, “HIGH” (APPROXIMATELY 10 VDC) = TUBE 1 SELECTED.
TUBE 2
“LOW” (APPROXIMATELY 0 VDC) = TUBE 2 SELECTED, “HIGH” (APPROXIMATELY 12 VDC) = TUBE 1 SELECTED. STATOR
TERMINAL
DS6 LIT INDICATES TUBE 1 SELECTED. DS5 LIT INDICATES TUBE 2 SELECTED. NEITHER LED LIT INDICATES A MISMATCH BETWEEN THE BLOCK
TUBE THAT HAS BEEN REQUESTED, AND THE TUBE THAT HAS ACTUALLY BEEN SELECTED (SEE # 5). J5-3
TUBE 2 TH
“LOW” (APPROXIMATELY 0 VDC) = INVERTER THERMAL SWITCH CLOSED (OR JUMPERED VIA JW4), “HIGH” (APPROXIMATELY 12 VDC) = THERMAL ON MD
INVERTER THERMAL SWITCH OPEN, OR JW4 JUMPER OMITTED ON RAD GENERATORS. SWITCH J5-4

THE TUBE 1 / TUBE 2 TELLBACK LOGIC CIRCUIT ENSURES THAT THE TUBE ACTUALLY SELECTED MATCHES THE TUBE THAT WAS
REQUESTED. FOR EXAMPLE, IF TUBE 2 WAS REQUESTED BY THE CONSOLE BUT TUBE 1 WAS ACTUALLY SELECTED BY THE H.T. TANK, GENERATOR INTERFA
THE LOGIC CIRCUIT WILL INDICATE A FAULT CONDITION.

DRAWN DATE
G. SANWALD 18 MAY 2000
CHECKED
S. BLAKE 18 MAY 2000
3 PHASE INDICO 100 GENERATORS USE ONE

PHASE 1 F5B
K5 D1

~ +
E23 INVERTER BOARDS DEPENDING ON GENERAT

R18, R19
~
O PAGE 5 FOR LOGIC LEVELS, E1 + E1 +

R20
PHASE 2 F5A DC BUS INVERTER INVERTER
TC, REFERENCED BY OUT BOARD BOARD
NAL SYMBOL: 3 PHASE AC

~
PHASE 3 E2 - E2 -
F5C
MAINS INPUT E11
-
NEUTRAL

R16, R17
R11
R10
E16 E9 F2
GROUND + I

-**
560 VDC
E8 E10 F1
IN

K1
DC BUS CHARGED DC BUS DUAL SPEED STARTER BOARD
+12V
SENSING DISCHARGE
F2
JW3 CIRCUIT CIRCUIT
1 (R5-R8, D3) (Q1, D10) T1
POSITION: SOFT START OK F1
J6-1 380/400/480 VAC
*

R48
ENERATORS 2 +12V
PROTECTION
R PINS 2-3
ENERATORS 3
CIRCUIT 1 5 1
U2
(U1C, Q7, ETC) 240 VAC

R12
R PINS 1-2 2 J4-10 J4-10 U1
+12VDC 4 5
4 2 D2 OK 208 VAC
K1 D3 J4-8 J4-8 N/C
2 1
DC BUS
D9 J6-5 120 VAC
S.S. +12V K2 OK
OK
JW2 +12V 94 VAC
1
R31

POSITION: SOFT START


GENERATORS 2 J2-1 P2-1 J6-6 73 VAC
DRIVER
R PINS 2-3 CIRCUIT
3 CNCTR
GENERATORS 3 D2 CLOSED D4 K5
(U3B, Q6, ETC) 52 VAC
R PINS 1-2 J4-13 J4-13 J2-2 P2-2
J6-7 F1 RETURN
J4-2 J4-2
K2
D8 J1-1 F1
SOFT START F4 120 / 240 VAC
FAULT SIGNAL R1, R2 J4-1 J4-1
TO AUXILIARY +12V J5-3 J1-3 F2
K1 52 / 73 / 94
BOARD, PAGE 3 J4-4 J4-4
J5-4 J1-4 F3
K1 COM
4 D5
+12V +12V
+12V J4-3 J4-3
J3-3 J2-3 TP4
J4-14 J4-14 J3-4 J2-4 TP1
J4-15 J4-15 J3-2 J2-2
TP1
J4-16 J4-16 +12V

J4-18 J4-18
TUBE 1 / TUBE 2 SELECT 5 J3-9 J2-9
COMMAND TO MD-0787 REFER TO MD-0764
D7 K3
J4-17 J4-17 LOW SPEED STARTER B

J10-3 FAN(S) USED ON FLU


+12V K4
J10-1 ONLY. DEPENDING O
R72 +12V ONE, TWO, OR THRE
D37 6
FLUORO
FLUORO FAN FAN ON
J4-5 K3 TUB
TIMER / DRIVER J4-5 D6 K4 J11-4 F2 J5-4
CIRCUIT S
(U11, Q9, ETC) J11-6 J5-6 (TW
THREE FAN TA
R&F GENERATORS ONLY UNITS ONLY H.T. TANK
E21 E17

J5-3 J5-4 J1-6 J1-5 J1-3 J8-3


AUXILIARY BOARD
240V * T2FOR(SHOWN TAPPED
400 VAC MAINS)
J8-1
OPTIONAL 400/480 VAC
***

200V *** 480 VAC GENERATORS


F3 J7-1 ***
230/277 VAC
FROM PAGE 3 J7-3
180V NEUTRAL OPTIONAL
J7-5
GROUND
AND T2 MUST BE TAPPED IN ACCORDANCE WITH THE NOMINAL AC MAINS VOLTAGE. 0V
ROOM INTERFACE CHASSIS
FER TO CHAPTER 2 OF THE GENERATOR SERVICE MANUAL. CONTINUED ON 3 PHASE POWER INPUT BOARD
240V PAGE 4
(REFER TO PAGE 2 FOR 1 PHASE POWER DRAWN DATE
IS VOLTAGE IS APPROXIMATELY 560 VDC FOR 400 V GENERATORS, AND APPROXIMATELY 200V
INPUT BOARD) G. SANWALD 10 MAR 2000 D
0 VDC FOR 480 V GENERATORS CHECKED________ ________
ONE OR TWO INVERTER MODULES DEP
K5 ON GENERATOR OUTPUT POWE
E33
LINE 1 F5A
230 MAINS BUS 650 VDC E1 + E1 +
1 PHASE AC LINE 2 VAC RECTIFIER CAPACITORS OUT
F5B E34 INVERTER INVER
MAINS INPUT BOARD BOA
VOLTAGE DOUBLER CIRCUIT E2 -
GROUND

R11
R10
DC BUS ASSEMBLY

P1-4 P1-1
J6-1 380/400/480 VAC TAPS
*T1

K1
J12-4 J12-1 NO CONNECTION

F2 240 VAC
J6-3
DC BUS CHARGED
F1 208 VAC
SENSING CIRCUIT
(R6-R8, R16-R21, D3, ETC)
1 J6-5 120 VAC
CONTINUED ON
J4-10 J4-10 PAGE 3
94 VAC
5 1
J4-8 J4-8
U1 J6-6 73 VAC
4 2 D2
52 VAC
+12V DC BUS
OK J6-7 F1 RETURN
J2-1 P2-1 K2

D4 K5
J4-13 J4-13 J2-2 P2-2

J4-2 J4-2 J5-3


K2
D8 J5-4
J4-1 J4-1
LOW SPEED
LIARY BOARD +12V +12V STARTER BOARD
J4-4 J4-4
ER TO PAGE 1 K1
F4 J3-3 REFER TO PAGE 1
J3-4
D5
J3-2
R12

J4-3 J4-3

J4-14 J4-14
D9
J4-15 J4-15 +12VDC J3-9
OK
J4-16 J4-16 +12V
J4-18 J4-18
J10-3
D7 K3 FAN(S) USED ON FLUORO GENERATORS
K4
J4-17 J4-17 J10-1 ONLY. DEPENDING ON THE APPLICATION,
ONE OR TWO FANS MAY BE USED

+12V
6 K3
J11-4
J11-6
H.T. TANK
J4-5 J4-5 D6 K4
REFER TO PAGE 1

J8-3
E21 E17 OPTIONAL 230 VAC
J8-1

ST BE TAPPED IN ACCORDANCE WITH THE NOMINAL


240V * T2FOR(SHOWN TAPPED
240 VAC MAINS)
F3 J7-1
J7-3 230 VAC
OPTIONAL
VOLTAGE. REFER TO CHAPTER 2 OF THE GENERATOR 200V J7-5
GROUND
MANUAL.
180V

ROOM INTERFACE CHASSIS


0V
CONTINUED ON 1 PHASE POWER INPUT BOARD
240V PAGE 4
DRAWN DATE
200V
G. SANWALD 10 MAR 2000 D
CHECKED________ ________
+35V
T1 +12V +12V
J7-1 F4 R71 +5V
26 VAC J6-4 J7-4 U34 TP16

R65
0V J7-3 C22 D31 J6-5 J7-5 +5 V
+/-35V REGULATOR
D32
26 VAC J7-6 F3
+12V +12V

R64
C21 D28
FROM J4-1 J1-1
PAGE 1, 2 TP5 J6-1 J7-1
J4-3 J1-3
J7-2
+12V TP1 TP15 J4-5 J1-5
15 VAC U5,U6
-35V -12V -12V J4-7 J1-7
J7-4 F1 R70 J6-2 J7-2
+12 VDC
0V REGULATOR J4-9 J1-9
C24, D29 J6-3 J7-3
J7-5
15 VAC C25 D27 J4-11 J1-11
F2 D33 U4 +12V
TO PAGE 1 J4-12 J1-12
R68
-12 VDC
REGULATOR J4-13 J1-13
D16 J4-15 J1-15
D30
C19 -12V +12V J4-17 J1-17
TO MD-0786 -12V J4-19 J1-19
R32

D1
+12V +12V +/- 12V/SS FAULT
D19 J5-5 J6-5 +/- 12V/SS FAULT TO GENERATOR DUAL SP
5.1V REF READY DETECTOR CIRCUIT ON
J5-6 J5-7 J5-3 J5-4 J1-6 J1-5 J1-3
AUXILIARY BOARD CONTROL BOARD, SEE MD-0761
DUAL
-
18 CONTROL BOARD OPTIO
+ STARTE
J6-6 J6-7 J6-3 J6-4 J8-6 J8-5 J8-3 U3C
9 INDICO
+35V +35V
8 -
JW1 J9-1 J1-1 F2
JUMPER POSITION:
+ +12V +12V
5 U3D
TUBE 1/TUBE 2 FLUORO RAD GENERATORS
SELECT SIGNAL -12V J9-4 J1-4
JUMPER "RAD"
TO MD-0765 RAD R&F GENERATORS -
CONTACTOR
CLOSED JUMPER "FLUORO" +
J9-3 J1-3
SIGNAL TO +12V U3A
MD-0765 R22 +12V J9-2 J1-2 F1
-12V -12V
+12V
R223

12VDC / SOFT START J9-5 J1-5


R217

Q1 SOFT START FAULT SIGNAL -35V -35V


R20 TP2
FAULT SIGNAL TO MD-0764, PAGE 1
R227

J9-6 J1-6
R21

FROM AUXILIARY
BOARD, PAGE 1
AUXILIARY BOARD FILAMENT BOARD ONE F
+12V 4 5 4 5 4 5
STAND
R228

GENERA
2 1 2 1 2 1 FILAMEN
RN4F

+35V
RN2D

RN2C

R226

U7 U40 U41
R225
R2

R11

R10

J1-1 F2 +12V
J1-25 J1-6 J1-10 J1-29 J1-18 J1-19 J2-14 J2-6 J2-15 J2-7 J1-4

J1-3

J10-25 J10-6 J10-10 J10-29 J10-18 J10-19 J3-14 J3-6 J3-15 J3-7 J1-2 F1
13 +5V
-12V
+15V
R27, R32

J1-5
10 +5V TP2
-35V
D1 +5V +5V J1-6
11 12
R14
RN11A

RN11I

10
U9
R9

Q4 FILAMENT BOARD
12 11
D P/S ON Q1
2 1
V DS34 DS35 DRIVER DRIVER DS22 DS23 DS2 DS4
R13

4 5 -15V
NT 4 5
2 1 GRN RED
TO 2.1 V
U16
TUBE 1/TUBE 2
SELECT SIGNAL
U16 FLUORO FLUORO
TO 2.1 V
LOW HIGH
TO 2.1 V
* THE POWER SUPPLY ON COMMAND (P/S ON) WHICH ENERGIZES
K1 / K2 ON THE POWER INPUT BOARD IS ISSUED BY THE GENERATOR
CPU BOARD AFTER THE +5 VDC RAIL IS DETECTED BY THE CPU.
U17 15 CURRENT 16 CURRENT 17 CURRENT
R33

TO MD-0787
SINK SINK SINK THE DC RAILS, INCLUDING THE +5 VDC RAIL, ARE ESTABLISHED
U24 WHEN THE SYSTEM ON COMMAND IS RECEIVED. REFER TO MD-0762.
DATA LATCH,
U27, U19 DATA LATCH DATA DATA
BUFFER BUFFER, &
DRIVER
& U16 & BUFFER LATCH LATCH
U27 U49 DRAWN DATE
*
BIT 0
U27, U19

BIT 2 BIT 7 BIT 3


G. SANWALD
CHECKED________
10 MAR 2000
________
D
J4-12 J5-12
REFER TO SYSTEM ON, MD-0762
24 VDC RETURN J4-14 J5-14 +5V
TP11
TP8 CONSOLE BOA
K3 TP7 ASSEMBLY SHOW
24 VDC J4-13 J5-13
+ 5 / -15VDC LINES USED ON 3
J4-15 J5-15 F1 POWER SUPPLY ONLY. REFER
+24V +15V & REGULATOR
(U28, L1, D9-D13, ETC) 23 X 56 CM CO
TP13 U5 TP1 RAD-ONL
TP13 R1
+15 V TP10
D3 REGULATOR -15V
18 VAC J1-2 F5 TP9 19

R81
+5V +5V
C10 TP3 TP2
0V J1-1 R3
+5 / +16VDC +12V 300 VAC J10-1

R2
POWER SUPPLY BACKLIGHT FLUORESCE
F6 U3
CIRCUIT POWER SUPPLY
J1-3 F3 (U47, Q4, T1, (Q7, Q8, T1,
+12 V J10-4
18 VAC C16 D17, D18, ETC.) REGULATOR C57, ETC)
K2 D1
J1-4 LCD DISPLAY
0V U2 TP7
J1-5 F4 R6
-12 V
18 VAC REGULATOR
CONSOLE BOARD (31 X 42 CM CONSOLE)
J1-7 F2
110 VAC U4 -12V TP5

R5
R4 220 VAC 220 VAC
J1-9 F1 -15 V
220 VAC -24V REGULATOR 110 VAC J2-1 J1-1 110 VAC
TP6 J2-3 J1-3 +24VDC
+24V
-15V
J2-6 J1-6
110 VAC U40 R7
R78 J2-7 J1-7
K1 ZERO CROSS LINE SYNC DS1
220 VAC DETECTOR TO MD-0767 J2-8 J1-8
D15 POWER ON
J2-9 J1-9

ROOM INTERFACE BOARD

+12V +12V
K1
+24V +24V
J10-13
J10-19
J10-11
K2 REFER TO SYSTEM ON, MD-0762 REFER TO MD-0757 (AEC) FOR
J10-16 PINOUTS OF THE DC RAIL CONNECTIONS
J10-17 ON THE AEC BOARD
-12V -12V
-24V -24V
K3

AEC BOARD

+5V +15V +24V +15V +15V


TP17 +15V +12V +5V
+12V
+12V J3-3 J13-3 R77 +12V
TP19

R78

R86

R76
-15V +5V J3-6 J13-6 R85 +5V J11-1
TP16
J3-1 J13-1 R75
J13-9 J13-21 J13-23 J13-11 J13-13 J13-17 J13-15 DS36 DS38 DS33 J11-5
GENERATOR INTERFACE BOARD J3-8 J13-8

J3-5 J13-5 R89


-12V TP20
THE DIGITAL I/O BOARD IS OPTIONAL WITH R&F R80 -12V
GENERATORS DS37 DS39
-15V TP18
-15V
REFER TO MD-0767 (DIGITAL INTERFACE) FOR TP4 TP21

R81

R90
PINOUTS OF THE DC RAIL CONNECTIONS +5V +15V +24V -15V
SHOWN TO THE RIGHT OF THIS TEXT J3-2 J13-2

J3-4 J13-4

J3-7 J13-7 -15V -12V

GENERATOR CPU BOARD


DIGITAL I/O BOARD
DRAWN DATE
G. SANWALD 10 MAR 2000 D
CHECKED________ ________
+12V +12V +5V
U8
J11-1 P1-1 +5 V
REGULATOR
D4
J11-5 P1-5

+5V +5V

J1-17 J2-17
+12V +12V
J1-18 J2-18
J1-15 J2-15
J1-19 J2-19
J1-20 J2-20

GENERATOR CPU BOARD REMOTE FLUORO REMOTE FLUORO


(FROM PAGE 4) CONTROL BOARD DISPLAY BOARD
REMOTE FLUORO CONTROL OPTIONAL WITH
INDICO 100 R&F GENERATORS

J5-12 +5V +5V +5V


REFER TO SYSTEM ON, MD-0762
J5-14 J8-1 J1-1
FROM GENERATOR TP2
INTERFACE BOARD + 5 / -20VDC
POWER SUPPLY J8-2 J1-2
(PAGE 4) J5-13 F1
CIRCUIT U31
J5-15 J8-23 J1-23
(U30, Q5, T1, -12 V
D7, D8, ETC.) REGULATOR J8-24 J1-24
J8-25 J1-25
-12V J8-26 J1-26

U32 CONSOLE DISPLAY BOARD


THESE ITEMS ARE 300 VAC
USED ON THE 23 X 56 BACKLIGHT
CM CONSOLE ONLY. POWER SUPPLY J10-1
-12V FLUORESCENT LAMP

J10-5

CONSOLE CPU BOARD (23 x 56 CM CONSOLE) LCD DISPLAY ASSEMBLY

J16-3 J8-3 +5V


TP3
FROM GENERATOR TP7
INTERFACE BOARD TP2 + 5 / -20VDC
(PAGE 4)
J16-8 J8-8 POWER SUPPLY
F1
CIRCUIT
(U12, L1, D2,
D3-D7, ETC.)
TP8

-20V
TP9
+5V 19

THESE ITEMS ARE 300 VAC J5-1


BACKLIGHT FLUORESCENT LAMP
USED ON THE “RAD-ONLY” POWER SUPPLY J5-5
CONSOLE ONLY. (Q1, Q2, T1,
C36, ETC.)

DRAWN DATE
G. SANWALD 10 MAR 2000 D
CONSOLE BOARD (RAD-ONLY CONSOLE) LCD DISPLAY ASSEMBLY CHECKED________ ________
E
REMARKS
NCE
THIS VOLTAGE WILL BE APPROXIMATELY 0 VDC WHEN THE DC BUS CAPACITORS ARE NOT CHARGED. THIS WILL RISE TO APPROXIMATELY 6 VDC WHEN THE DC BUS CAPACITORS ARE FULLY CHARG
THE DC BUS CAPACITORS MUST CHARGE WITHIN APPROXIMATELY 0.25 SECONDS OF THE GENERATOR BEING SWITCHED ON. IF THE DC BUS CAPACITORS DO NOT CHARGE NORMALLY, THE SOFT S
OK PROTECTION CIRCUIT ENERGIZES RELAY K1 (SEE # 4) AND INHIBITS OPERATION OF THE SOFT START DRIVER CIRCUIT (SEE # 3).
“LOW” (APPROXIMATELY 0 VDC) COMMANDS THE MAIN CONTACTOR K5 ON THE POWER INPUT BOARD TO CLOSE. “HIGH” (APPROXIMATELY 12 VDC) = CONTACTOR OPEN. THIS OUPUT WILL NOT SWI
“LOW” IF THE DC BUS CAPACITORS ARE NOT CHARGED (SEE # 1 & 2).
K1 REMAINS DE-ENERGIZED (CONTACTS AS SHOWN) IF NO SOFT-START FAULT IS DETECTED. THEREFORE, K1 AND K2 ON THE POWER INPUT BOARD WILL ENERGIZE WHEN THE GENERATOR IS SW
ON. A SOFT-START FAULT ENERGIZES K1 ON THE AUXILIARY BOARD, DE-ENERGIZING K1 ON THE POWER INPUT BOARD. THIS WILL INHIBIT FURTHER DC BUS CHARGING.
“LOW” (APPROXIMATELY 0 VDC) = TUBE 2 SELECTED, “HIGH” (APPROXIMATELY 12 VDC) = TUBE 1 SELECTED.
“LOW” (APPROXIMATELY 0 VDC) = FLUORO FAN(S) ON, “HIGH” (APPROXIMATELY 12 VDC) = FLUORO FAN(S) OFF. FAN(S) ARE SWITCHED ON DURING PULSED OR CONTINUOUS FLUORO OPERATION, A
REMAIN ON FOR APPROXIMATELY 20 MINUTES AFTER SWITCHING TO RAD MODE.
“LOW” INDICATES CONTACTOR CLOSED (SEE # 3). THE CONTACTOR CLOSED SIGNAL OCCURS APPROXIMATELY 10 SECONDS AFTER INITIAL GENERATOR TURN-ON, ASSUMING NORMAL DC BUS CHA
“HIGH” (APPROXIMATELY 12 VDC) = RAD / PULSED FLUORO MODE. “LOW” (APPROXIMATELY 0 VDC) = CONTINUOUS FLUORO MODE. USED ON R&F GENERATORS ONLY.
“HIGH” (APPROXIMATELY 12 VDC) = PULSED FLUORO / LOW POWER MODE. “LOW” (APPROXIMATELY 0 VDC) = HIGH POWER RAD MODE. NOT USED ON ALL MODELS, REFER TO MD-0786 FOR DETAILS
24 VDC (APPROXIMATELY) ENERGIZES K1 AND / OR K2 ON THE POWER INPUT BOARD, INITIATING THE POWER-ON SEQUENCE. SEE # 4.
“HIGH” (APPROXIMATELY 5 VDC) = TUBE 2 SELECTED. “LOW” (APPROXIMATELY 0 VDC) = TUBE 1 SELECTED.
“HIGH” (APPROXIMATELY 5 VDC) = RAD / PULSED FLUORO MODE. “LOW” (APPROXIMATELY 0 VDC) = CONTINUOUS FLUORO MODE. USED ON R&F GENERATORS ONLY.
“HIGH” (APPROXIMATELY 5 VDC) = PULSED FLUORO / LOW POWER MODE. “LOW” (APPROXIMATELY 0 VDC) = HIGH POWER RAD MODE. NOT USED ON ALL MODELS, REFER TO MD-0786 FOR DETAILS.
DS9 LIT = CONTACTOR CLOSED, DS10 LIT = CONTACTOR NOT CLOSED.
DS34 LIT = GENERATOR ON COMMAND ISSUED (CONSOLE PASSED ALL SELF TESTS). DS35 LIT = GENERATOR ON COMMAND NOT ISSUED (DURING CONSOLE SELF TESTS, OR IF SELF TESTS FAILED
DS22 LIT = FLUORO SELECTED, DS23 LIT = RAD SELECTED.
DS2 LIT = PULSED FLUORO / LOW POWER MODE. DS4 LIT = HIGH POWER RAD MODE. SEE # 13.
D1 LIT INDICATES + OR - 12 VDC FAULT, OR SOFT START FAULT.
THE VOLTAGE WAVEFORM AT THIS TEST POINT IS DEPICTED IN FIGURE 1 BELOW.

18 s

4V

-8 V

DRAWN DATE
G. SANWALD 10 MAR 2000 D