You are on page 1of 26

website http://www.lgappliances.

com

LG
LG Portable
Air Conditioner
SERVICE MANUAL
MODEL: LP1215GXR

CAUTION
BEFORE SERVICING THE UNIT, READ THE SAFETY
PRECAUTIONS IN THIS MANUAL.
ONLY FOR AUTHORIZED SERVICE PERSONNEL.
CONTENTS
1. SAFETY PRECAUCTION .............................................................................................................................2
2. SPECIFICATIONS .........................................................................................................................................3
2-1 Spec .....................................................................................................................................................3
2-2 Dimensions ...........................................................................................................................................3
3. FEATURES ....................................................................................................................................................4
4. INSTALLATION ....................................................................................................................................................6
4-1 Preparing for Installation ........................................................................................................................6
4-2 Selection of Installation Location ...........................................................................................................7
4-3 Window Vent Pane land Extensions .....................................................................................................8
4-4 Installationin Vertical Sliding Windows ..................................................................................................9
4-5 Installation in casement style windows ...............................................................................................11
5. CARE AND CLEANING ...............................................................................................................................13
5-1 Cleaning the case ...............................................................................................................................13
5-2 Cleaning the air filter............................................................................................................................13
5-3 Emptying the water collection tank .....................................................................................................14
5-4 STORING THE AIR CONDITIONER .................................................................................................15
6. OPERATION ...............................................................................................................................................16
6-1 Control Panel and Remot ....................................................................................................................16
7. DISASSEMBLELY .......................................................................................................................................20
8. CIRCUIT DIAGRAM ... ....................................................................................................................................22
8-1 Circuit diagram ....................................................................................................................................22
8-2 PCB picture .........................................................................................................................................23
8-3 Wiring diagram.....................................................................................................................................24
9. TROUBLE SHOOTINGS ..............................................................................................................................24
9-1 Safety caution .....................................................................................................................................24
9-2 Error code summary ............................................................................................................................24
10. Exploded View ...........................................................................................................................................25

1. SAFETY PRECAUCTION
Please read the following instructions before servicing your portable air conditioner.
1. Unplug the power before handling any electrical components.
2. Check the rated current, voltage, and capacity.
3. Take caution not to get water near any electrical components.
4. Use exact replacement parts.
5. Remove any objects from the top prior to tilting the product.

Copyright ©2014 LG Electronics. Inc. All right reserved. -2-


LGE Internal Use Only
Only for training and service purposes
2. SPECIFICATIONS
2-1 SPEC
Buyer Model LP1215GXR
PERFORMANCE
Btu performance (Cooling) 12000
Dehumid. ( Pts/Hr) 3.4
Dry Air Flow (CFM) 255
dBA Level (Front) 55
ELECTRICAL RATINGS
Voltage / 60 Hz 115

Plug Type

Watts 1270
Rated Amps 11.5
FEATURES
Display Panel LED
Thermostat Control YES
Remote Controller LCD Remote Controller
Control Button Type Standard
Auto Swing Yes
Energy saver switch Yes
Auto Restart Yes
Auto Door Open/Close System Yes
Timer 24Hr,On/Off
Fan Speed : Cooling 3
Fan Only 3
Compressor Rotary
Indoor / Outdoor Fan Type Blower
Type Air Discharge Inclined Front
Water Full Indicator Yes(check)
Outdoor Vent / Exhaust Exhaust Only(1.5M)
Power Cord
Chassis Type Fixed
Panel Color Gray
Easy-Roll Casters Yes
Air Filter Washable
Window Installation Kit Yes
DIMENSIONS & WEIGHTS
Net Height_inch(mm) 32.68 (830)
Width 15.55 (395)
Depth 15.55 (395)
Carton Height_inch(mm) 34.65 (880)
Width 18.27 (464)
Depth 19.37 (492)
Net Weight_lbs.(kg) 67.24 (30.5)
Shippling Weight_lbs.(kg) 74.96 (34.0)
Stuffing Quantity (20ft/40ft/40ft High) 112/240/340

2-2 Dimensions
830 395
395

Copyright ©2014 LG Electronics. Inc. All right reserved. -3-


LGE Internal Use Only
Only for training and service purposes
3. FEATURES

Escutcheon
Swing panel

Front panel

Wheel

Remote Holder
Handle

Remote Holder

Power cord holder

Drain pipe

Filter Grille

Copyright ©2014 LG Electronics. Inc. All right reserved. -4-


LGE Internal Use Only
Only for training and service purposes
3. FEATURES

C-Box Cover

C-Box

Air Guide

Filter
Condenser
Drain pan Evaporator

Air Guide

Comp
Base pan

Wheel

Air Guide
Outlet

Drain hole
Motor

Copyright ©2014 LG Electronics. Inc. All right reserved. -5-


LGE Internal Use Only
Only for training and service purposes
4. INSTALLATION
4-1 PREPARING FOR INSTALLATION

?):616/ <PMIQZKWVLQ\QWVMZQ[PMI^a =[M\_WWZUWZMXMWXTM\W


TQN\IVLQV[\ITT\PM]VQ\ .IQT]ZM\WLW[WKW]TLZM[]T\QVJIKSQVR]ZaWZW\PMZQVR]ZQM[
Panel B (9’’)
EXHAUST COMPONENTS
The following components are used for window venting.
Not all components are used for every installation.

Panel A (18’’) Panel C (17’’) Panel D (17’’)


Flexible Venting Hose Diffuser
1 Window Vent Panel 3 Extension Panels

Window Installation Kit (includes 1 Window


Vent Panel and 3 Extension Panels)

2 Type A Foam Seals 1 Type B Foam Seal 2 Type C Foam Seals


(Adhesive) (Non-adhesive) (Adhesive type-Shorter)

Security Bracket 2 Type A Screws 1 Type B Screw 1 Type C Screw

Copyright ©2014 LG Electronics. Inc. All right reserved. -6-


LGE Internal Use Only
Only for training and service purposes
4. INSTALLATION
4-2 SELECTION OF INSTALLATION LOCATION

For best performance, allow at least 20 in


(50.8 cm) of air space behind the unit for
good air circulation.

Copyright ©2014 LG Electronics. Inc. All right reserved. -7-


LGE Internal Use Only
Only for training and service purposes
4. INSTALLATION
4-3 WINDOW VENT PANEL AND EXTENSIONS
18" to 50" (46 to 127 cm) 18" to 50" (46 to 127 cm)
A B C D
18" 9" 17" 17"
(46cm) (23cm) (43cm) (43cm)
18"(46cm) A
19"- 26" (48cm - 66cm) B
27"- 34" (69cm – 86cm) C
35"- 50" (89cm – 127cm) D
Please check your window length and choose the
panels that will fit from the above table.
If the length of your window requires more than two
panels, use one type A screw to fasten the panels
once they are adjusted to the proper length.

For window openings from 19" to 26“ (48cm to 66cm),


For an 18“(46cm) window opening, use the use the window vent panel (Panel A) and extension
window vent panel by itself. Panel B.
Fig. “A” Fig. “B”

For window openings from 27“ to 34“ (69cm to 86cm), For window openings from 35" to 50“(89cm to 127cm),
use the window vent panel (Panel A) and extension use the window vent panel and extension panels
Panel C. (C and D).
Fig. “C” Fig. “D”

Copyright ©2014 LG Electronics. Inc. All right reserved. -8-


LGE Internal Use Only
Only for training and service purposes
4. INSTALLATION
4-4 INSTALLATION IN VERTICAL SLIDING WINDOWS

18" and 50" (46cm and 127 cm)

Cut the adhesive foam seal A and C strips to


the proper lengths, and attach them to the
window sash and frame as shown.

Cut the non-adhesive foam seal B strip to If desired, install the security bracket with a
match the width of the window. Insert the seal type B screw as shown.
between the glass and the window frame to
prevent air and insects from getting into the
room.

Copyright ©2014 LG Electronics. Inc. All right reserved. -9-


LGE Internal Use Only
Only for training and service purposes
4. INSTALLATION

Insert the diffuser into the vent panel then slide


the diffuser left to lock it.

First insert diffuser into the vent panel fully and Use the type C screw to fix the diffuser more
then slide it to lock. firmly in place, if desired.

Copyright ©2014 LG Electronics. Inc. All right reserved. - 10 -


LGE Internal Use Only
Only for training and service purposes
4. INSTALLATION
4-5 INSTALLATION IN CASEMENT STYLE WINDOWS

Cut the adhesive foam seal A and C strips to


the proper lengths and attach them to the
window sash and frame as shown.

Cut the non-adhesive foam seal B strip to


match the window height. Insert the foam seal
between the glass and the window frame to
prevent air and insects from getting into the
room.

Copyright ©2014 LG Electronics. Inc. All right reserved. - 11 -


LGE Internal Use Only
Only for training and service purposes
4. INSTALLATION

Insert the diffuser into the vent panel and slide


the diffuser down to lock.

First insert diffuser into the vent panel fully and Use the type C screw to fix the diffuser more
then slide it to lock. firmly in place, if desired.

Copyright ©2014 LG Electronics. Inc. All right reserved. - 12 -


LGE Internal Use Only
Only for training and service purposes
5. CARE AND CLEANING

Failure to follow the above precautions could result in electric shock or personal injury.

5-1 CLEANING THE CASE

5-2 CLEANING THE AIR FILTER

Copyright ©2014 LG Electronics. Inc. All right reserved. - 13 -


LGE Internal Use Only
Only for training and service purposes
5. CARE AND CLEANING
5-3 EMPTYING THE WATER COLLECTION TANK

USE OF A DRAIN HOSE WHEN USING THE DRY MODE


If you wish to use the DRY mode because the unit is running in high humidity or for other reasons,
remove the drain cap and rubber plug from the back of the unit.
Purchase and install a drain hose (1/2" inside diameter) on the back of the unit and place the
open end of the hose in a suitable drain location or outdoors.

FL APPEARS IN THE DISPLAY


The water collection tank is full. Drain the tank and restart the air conditioner.

Copyright ©2014 LG Electronics. Inc. All right reserved. - 14 -


LGE Internal Use Only
Only for training and service purposes
5. CARE AND CLEANING
5-4 STORING THE AIR CONDITIONER
If the air conditioner will not be used for an
extended period of time:

Copyright ©2014 LG Electronics. Inc. All right reserved. - 15 -


LGE Internal Use Only
Only for training and service purposes
6. OPERATION
6-1 CONTROL PANEL AND REMOTE

Adjust the set temperature up or down, or adjust the


timer delay time.

Removes moisture from the heat exchangers


and helps prevent odor from forming. This
function can be activated from the remote only.

Switches the temperature display between degrees


Celsius (ºC) and degrees Fahrenheit (ºF).

If there is a power failure during operation, the unit will resume operation with the same settings as
before the power failure.

Copyright ©2014 LG Electronics. Inc. All right reserved. - 16 -


LGE Internal Use Only
Only for training and service purposes
6. OPERATION
6-2 USING THE CONTROLS
Control panel buttons shown. Operation Always point the remote at the sensor. The
using the remote control is the same, unless remote may not work if the sensor is in bright
specifically noted.NOTE:The remote sensor is light or if there is not a clear path between the
located under the air discharge and on the top remote and the sensor.
of the front panel.
MODE
POWER Press the MODE button to select the operating 8
Press the POWER button to turn the air mode(COOL,FAN,DRY , ENERGY SAVER)
conditioner ON or OFF. When you turn the air for the air conditioner.
conditioner on, an ascending And you can see the active
tone will play and the LED mode through the LED Display.
display will show the set The default setting is COOL.
temperature and any active Press the MODE button to
change to FAN, press again to change to DRY,
mode.The air discharge on the top of the air
again to change to ENERGY SAVER
conditioner wil automatically open.
and again to return to COOL.
When turning the air conditioner off, you will
hear a descending tone and the air discharge
on the top of the air conditioner will close. COOL → FAN
Any control settings such as Mode, Set
Temperature, Auto Swing, etc. will be retained →
in memory when the power is off.
NOTE: When turned on after being unplugged, ENERGY DRY
the air conditioner will automatically reset to SAVER
COOL mo d e,with atemperature setting of 22°C.
Any settings will need to be re-entered.

Mode Features
COOL Compressor runs and cools the room. Use the
/ and FAN buttons to set the desired
temperature and circulation fan speed.
FAN Fan circulates air but compressor does not run.
Use the FAN button to set the desired fan speed.
DRY Dry mode is used to remove humidity from the room
without additional cooling. Once the set temperature
is reached, the compressor and circulation fan turns
off and only the exhaust fan will run. Fan speed is
pre-set and cannot be adjusted.

ENERGY Under normal operation, the exhaust fan cycles on


SAVER and off with the compressor, and the circulation fan
runs at the set speed.
The mode helps reduce power consumption by
automatically turning off the circulation fan as well
as the exhaust fan when the compressor is off. The
air conditioner will automatically cycle both fans on
and off with the compressor as needed for cooling.

Copyright ©2014 LG Electronics. Inc. All right reserved. - 17 -


LGE Internal Use Only
Only for training and service purposes
6. OPERATION
FAN SPEED

In COOL and DRY modes, the / (TEMP/TIMER)


buttons adjust the set temperature up to 86°F (30°C)
or down to 60°F(16°C), in one degree increments.

at the same time, or by pressing the

Press the TIMER button to see the delay time you


set displayed on the LED display panel.
To change the set delay time, press the TIMER
button and adjust the time when the number begins
to blink.
To cancel the Timer function, press the TIMER
button and adjust the number to 0 when the
number begins blinking. The function will be
canceled in a few seconds.
An easier way to cancel the timer function is to
press the TIMER button, then press it again
when the number begins blinking.

Do not unplug the air conditioner while


using the timer function.

Copyright ©2014 LG Electronics. Inc. All right reserved. - 18 -


LGE Internal Use Only
Only for training and service purposes
6. OPERATION

The AUTO SWING

on

Press this button to switch the


displayed temperature from
ºF to ºC or vice versa.

Copyright ©2014 LG Electronics. Inc. All right reserved. - 19 -


LGE Internal Use Only
Only for training and service purposes
7. DISASSEMBLELY

Copyright ©2014 LG Electronics. Inc. All right reserved. - 20 -


LGE Internal Use Only
Only for training and service purposes
7. DISASSEMBLELY

Copyright ©2014 LG Electronics. Inc. All right reserved. - 21 -


LGE Internal Use Only
Only for training and service purposes
8. CIRCUIT DIAGRAM
8-1 Circuit diagram
Main PCB
AC-N
U5 +12V U9 VCC
N
ACN1 1 D2 1 V V 3 1 V V 3
IN OUT IN OUT
XS1 XS2 C12 +12V
C3 GND GND C15
3 D1 C11 L
ACN2 1 1 C5
2

2
ZNR 2
1
D4 RAY2
C1

D3 SLI-S-112DM
L1
YJ
L1
AC-L
FUSE
L RAY3 FAN_H

U3 ULN2003 SJ-S-112DM
1 16 HFAN
1IN1OUT
XTAL MC3021_IN 2 15 M3021_Out L1
2IN2OUT
XIN XOUT 3 14
3IN3OUT
XS6 VCC P15 4 13 PHD_Out
4IN4OUT RAY4
P13 5 12 PHC_Out FAN_M
1 5IN5OUT
P37 P16 6 11 PHB_Out
2 6IN6OUT
P36 P14 7 10 PHA_Out
3 7IN7OUT
P35 8 9 MFAN
4 R9 GNDVDD +12V
5 L1
P31 C6
6
P30 104
7
REMOT RAY5 1 H
8
PHD_Out U8 2 M XS8
9 C9 FAN_L
PHC_Out 1 32 P37 3 L CN-FAN
10 VSS (AIN5)P37 N
PHB_Out XIN 2 31 P36 4
11 XIN (AIN4)P36 LFAN
PHA_Out C7 XOUT 3 30 P35
12 XOUT (AIN3)P35 N
C14 4 29 AD-RT
13 TEST (AIN2)P34
5 28 AD-PT
VDD (AIN1)P33 L1
TJC2004-13A +12V SDA 6 27 ‫ؤ‬ƺũȱ
P21 (AIN0)P32
VCC SCL 7 26 P31
P22 P31
RESET 8 25 P30 RAY1 1 SX9
/RESET P30 VCC N
REMOT 9 24 2 VALVE
P20 P12
BYJ 10 23 P11
P00/TXD P11
BMFAN 11 22 P10 R16 R15 R14 R13 R12
P01/RXD P10 VALVE
BLFAN 12 21 BHFAN YPD COOL LCD 1K
P02 P07 YPQ F
MC3021_IN 13 20 BVALVE
P03 P06
14 19 P05
P04 P05 P15 P13 P05 P14 P16
P14 15 18 P13
P14 P13
P16 16 17 P15 R17 R10 R11 R4 R5
P16 P15
YPF HEAT C LED 2K
TMP86FH09AG YPF1 L1
J5
6*10
R3
R2
C8 VCC
104 2
+12V U4
VCC 3
R6 1 6 C4
U6 1 6
R8 R7 1
1 8 R1 U2
A0 VCC M3021_Out 2 5 2 XS7
2 7 D5 RESET 2 5 N
A1 WP 1
3 6 SCL
A2 SCL 3 4
4 5 SDA 1 3 3 4
GND

GND SDA Vin Vout


24C02 C10
U7 VCC
2

C13 C16
NJɫৠ̸ U1
1 16
AD-PT 1IN1OUT
4 2 15
2IN2OUT
3 SX4 BHFAN 3 14 HFAN
AD-RT 3IN3OUT
2 BVALVE 4 13 VALVE
PTRT 4IN4OUT
1 BYJ 5 12 YJ
5IN5OUT
BMFAN 6 11 MFAN
6IN6OUT
BLFAN 7 10 LFAN
7IN7OUT
࣬(ʙ)ůɫӽʥ VCC
VCC R23 R24 8
GNDVDD
9
+12V
C2
R20
R25 R18
෗ ʏ VCC
R19
R22 P10
‫ؤ‬ƺũȱ 3
1 XS5 XS3
J1 J2 J3 J4 P11 2
෗ ҁ 6*10 6*10 6*10 6*10
2 CN-HP
R21 1
CNWF

VCC
޺Ыʏɽ̸ UI-8 UI-8 XS6-5 U8-5
NJɫէ ֻϝৠ̸뻭
Ыʏɽ̸ ǭ‫ޕ‬я 1003-1326A HET-YA-YPQ-P ‫׷ڐ‬ĈՄȔѣ

ѳʹ ʕۨ ʏ Ɵ Զ ʥ ȶʔ Ȥૼ
‫ڑ‬ Ϲ ിӆŠƦक़ғĩߞ̑
̑ʏ ԶѤ

ū ʿ ҁŢ ࣪Ѥ
ඩभ ūʿ դ Ѯ lj Ѯ
̈Ǖ뻭 V01

Display PCB
࣬( ʙ) ůɫӽʥ
޺Ыʏɽ̸

NJɫৠ̸
ū

‫ڑ‬


Ыʏɽ̸

ʏ
ʿ

12V
NJɫէ
ǭ‫ޕ‬я
̑ʏ
ѳʹ
ඩभ
ҁŢ

12V LED2 LED9


CN-DISP CN-SM C2 Q3
Rec_test R9 seg13 ‫ ܄‬Grid1 seg1_C ‫܄‬ Grid1
1 5 2
STEPA COOL
2 4 1 삸
STEPB
3 3 AF LED3 LED12
STEPC Q2
4 2 BUZ1 R12 R10
STEPD
5 1 seg14 ‫ ܄‬Grid3 seg9 ‫܄‬
Rec_test
6 C10 FAN Grid3
BUZ2
7 R8 LED4 seg10
BUZ1 BUZZER1 ε
8
9 ‫ ܄‬Grid2
DI_O POWER
10 DRY
CLK
ūʿ
࣪Ѥ
ԶѤ
ʕۨ

11 LED5 LED10
STB 5V
12
13 ‫ ܄‬Grid1 seg9 ‫܄‬
C9 FRQ E-Saver
Q1 HIGH
C8 BUZ2 R11
LED11

seg10 ‫܄‬ Grid2


5V
LOW
5V
R7 R6 R5 C7
LED13
ֻϝৠ̸뻭1003-1326B

U1
1 28 seg10 MID Grid1
ʏ Ɵ Զ ʥ

NC Gnd
դ

DI_O R2 2 27 Grid1
DI/O Grid1
R3 3 26 Grid2
CLK CLK Grid2
4 25
R4 STB Gnd LED1
STB 5 24 Grid3
Key1 Grid3 C4 C11
6 23
Key1_1 Key2 Grid4 seg12 ‫܄‬ Grid1
7 22
Ѯ

Key2 Vdd Gnd


seg1_C 8 21 TIMER
Seg1/ks1 Vdd LED8
C6 C5 C3 seg2_e 9 20 seg14
Seg2/ks2 Seg14/Grid5
seg3_DP 10 19 seg13 5V
Seg3/ks3 Seg13/Grid6 ‫ ܄‬Grid3
J1 seg4_b 11 18 seg12
seg8_d seg8_d Seg4/ks4 Seg12/Grid7 숳
seg5_a 12 17 seg10
ȶʔ Ȥૼ

J2 J9 Seg5/ks5 Seg10/ks10
lj

GND GND Grid3 Grid3 seg6_f 13 16 seg9


Seg6/ks6 Seg9/ks9
J3 J10 Grid1 seg7_g 14 15 seg8_d
Key2 Key2 Grid1 Seg7/ks7 Seg8/ks8
Grid1 J4 Grid1 Grid2 J11 Grid2
Ѯ

5V J5 5V Grid3 J12 Grid3


seg1_C J6 seg1_C Grid2 J13 Grid2
Key1 J7 Key1 Grid3 J14 Grid3 seg7_g seg6_f
ിӆŠƦक़ғĩߞ̑

Key1_1 Grid3
̈Ǖ뻭

J8 seg3_DP J15 seg3_DP


10

Grid3 Grid3 SW3 seg5_a


9
8
7
6

D2
5V D5 SW1 seg3_DP J16 Key1 seg4_b
‫׷ڐ‬ĈՄȔѣ
HET-YA-YPQ-D-V01

seg1_C Key1 UP LED7


g

J18
f
a
C1

5V 5V
TIME D6 SW6
seg8_d J19 seg8_d R1
RCV1 SW2 Key2_2
V01

D1 1 2
3 Rec_test seg2_e J17 Key1
Key2_2 J20 Key2_2 OUT SWING
2 Key2
VS MODE D3 SW4
Grid2 J21 Grid2 1 . .
C2
dp

GND seg4_b KEY2_1


d

e
c

J22 C1 D4 SW5
seg8_d seg8_d KEY2_2 DOWN
SPEED SW7 Grid2
1
2
3
4
5

D7 seg8_d seg1_C
KEY2 seg1_C KEY2_2
seg3_DP seg2_e
POWER

Copyright ©2014 LG Electronics. Inc. All right reserved. - 22 -


LGE Internal Use Only
Only for training and service purposes
8. CIRCUIT DIAGRAM
8-2 PCB picture

Main PCB

Connect the Connect the motor Connect the water Connect the Display
transformer input pump motor PCB

Connect the Temp


sensor

Connect the Lever


Switch
Connect the
transformer output

Display PCB

Copyright ©2014 LG Electronics. Inc. All right reserved. - 23 -


LGE Internal Use Only
Only for training and service purposes
8. CIRCUIT DIAGRAM
8-3 Wiring diagram

9. TROUBLE SHOOTINGS
9-1 Safety caution

9-2 Error code summary

Copyright ©2014 LG Electronics. Inc. All right reserved. - 24 -


LGE Internal Use Only
Only for training and service purposes
10. EXPLODED VIEW
731270

135510 567480 Panel B (9’’)

261704 249950
W0CZZA 2 Type A Foam Seals
2 Type C Foam Seals
(Adhesive type-Shorter)
267110
(Adhesive)

268711B 648600 Panel A (18’’) Panel C (17’’) Panel D (17’’)

1 Window Vent Panel 3 Extension Panels

Window Installation Kit (includes 1 Window


Vent Panel and 3 Extension Panels)

W0CZZB
249940
1 Type B Foam Seal
(Non-adhesive)

352390
264110

Security Bracket 2 Type A Screws 1 Type B Screw 1 Type C Screw

135500A
238310
237200 268711A

W4810B 551030 352380A


354210 W4810A
552101
352380B W37400
147590A

147590B

W50060C
146811
147590C

135500B

137210
346811B 437213

266010 237205 152302A


W49301

W50060A
330860

352380C
346811A
349480 336610
359012 435313
148000

W50060B

35211B
567502
152302B 435300

554160
35211A

550140

130410

144410

Copyright ©2014 LG Electronics. Inc. All right reserved. - 25 -


LGE Internal Use Only
Only for training and service purposes
US Service call Number # : 1-888-865-3026

CANADA Service call Number # : (888) LG Canada, (888) 542-2623