You are on page 1of 96

In complete control of power

Electrical Power Products

■ Transformers and wound components


■ Power electronics

Catalogue reference
EPP 0216

■ Thermal management products


■ Transformer and panel accessories
Catalogue reference
EPP 0216

Eastern Transformers and Equipment Ltd


Units H1 & H2 Overland Business Park
Sudbury Road
Great Whelnetham
Bury St Edmunds
Suffolk
England
IP30 0UL

If you require technical assistance, delivery times or prices


please contact us on….

Telephone +44 (0) 1284 388033 (3 lines)


Fax +44 (0) 1284 386969

Email info@ete.co.uk
Web www.ete.co.uk

How to find us

In the interest of continuous improvement ETE reserves the right to alter designs
and specifications without notice.

Where data is critical please check with our technical sales team
THE INTERNET

Key email addresses


and contacts

General email addresses:

For general information


info@ete.co.uk

For sales and ordering


sales@ete.co.uk

ETE contact email addresses:


Managing director (sales and marketing)
Bob Tapping
bob@ete.co.uk

Company secretary
Julie Tapping
julie@ete.co.uk

Administration director (credit control and sales ledger)


Hannah Bayes
hannah@ete.co.uk

Works director (production control)


Lindsay Tapping
lindsay@ete.co.uk

Works manager
Nick Cracknell
nick@ete.co.uk

Sales manager
Steve Gardner
steve@ete.co.uk

Marketing
Tony Harper
tony@ete.co.uk

Scottish sales representative


Ken Neill
ken.neill@ete.co.uk

Our website
with ecommerce stock check and ordering facility

Our website contains much of the information shown in this catalogue.

A UK map of area distributor locations is shown for local supplies of ETE products.

Our ecommerce ordering facility is constantly being developed to offer comprehensive


ranges of standard products for single orders or registered accounts.

Live stock quantities are indicated if stock levels need to be checked for urgent orders.
Our website

Visit our website at www.ete.co.uk


INTRODUCTION AND FULL CATALOGUE INDEX

Since our establishment in 1984, ETE has constantly strived to match the fast pace of technical and commercial changes in
the UK controls, automation and machine building markets. We have designed and developed distinctive ranges of
transformers, power electronics and complimentary products for these prime markets.

Our catalogue is divided and colour coded into four key product sectors as indicated below.

Contents
Transformers and wound components Power electronics

Thermal management products Transformer and panel accessories

Pages 1 & 2 Transformers and wound components (sub index)

Pages 3 & 4 Stock transformers from 25VA to 7.5kVA for control panels and general use
Pages 5 to 16 Custom built transformers, comprehensive ranges and sizes for a wide range of applications
Page 17 Stock range of wall or floor mounted transformers with 110V socket outlets
Page 18 Custom built enclosed transformers
Pages 19 & 20 Portable tool and portable site transformers
Pages 21 & 22 Standard ranges of 3ph line reactors
Page 23 Custom built inductive reactors and DC chokes
Page 24 UL/CSA approval and transformer data for enclosed transformers to IP65 or for Ex rated transformers
Pages 25 & 26 Variable autotransformers 1ph and 3ph, open or enclosed

Pages 27 & 28 Power electronics (sub index)

Pages 29 to 35 Stock ranges of DIN rail mounted switched-mode power supplies


Page 36 RS series of low cost miniature power supplies from 15W to 150W
Pages 37 to 40 RSP, PSP & RST ranges of switched-mode power supplies from 75W to 5000W
Pages 41 to 44 HLG series of harsh environments switched-mode power supplies from 40W to 600W & HEP 600W series
Page 45 DC/DC converters from 15W to 1000W with 24V DC outputs
Page 46 DRC series of DIN rail mounted switched-mode power supplies with fully enclosed security series
Page 47 Stock series of single output battery chargers with UPS function & ‘all in one’ chargers with backup function
Page 48 AC/DC and DC/DC converters and AC/DC battery chargers
Pages 49 & 50 Unregulated and smoothed 24V DC power supplies and 24V DC switched mode units
Page 51 Constant voltage transformers (CVT)
Page 52 Line interactive uninterruptible power supplies (UPS)
Page 53 & 54 DC buffer modules and DC-UPS series
Page 55 & 56 EMC filters 1ph and 3ph

Pages 57 & 58 Thermal management products (sub index)

Pages 59 & 60 AC & DC cooling fans and accessories


Pages 61 & 62 AC & DC filter fans and exhaust filters
Page 63 Enclosure roof fans or top ventilators
Pages 64 to 66 Thermostats, hygrostats and hygrotherms
Pages 67 & 68 Anti-condensation heaters

Pages 69 & 70 Transformer and panel accessories (sub index)

Pages 71 to 74 Batteries, battery modules, battery holders and battery chargers


Page 75 IP65 hinged windows with or without back boxes plus DIN rail brackets
Page 76 DIN rail mounted sockets and industrial plugs and sockets
Pages 77 & 78 Panel lighting, (fluorescent and LED) and lead extensions
Pages 79 & 80 Distribution blocks 1ph and 3ph and also 2 pole and 4 pole
Page 81 DIN rail and DIN rail brackets plus cut and punch service and engraving service
Page 82 Bus bar insulators and copper bus bar either plain or cut to length and fabricated
Page 83 Transformer accessories and control panel accessories
Pages 84 to 85 Transformer and equipment enclosures from IP22 to IP65
Page 86 Transformer enclosures for outdoor use to IP55

Pages 87 to 89 IP ratings, guide to hazardous areas and glossary of terms

ETE ...........in complete control of power


YELLOW SECTION

ETE is a leading UK transformer designer and manufacturer. We hold one of the largest and most comprehensive
ranges of control circuit transformers for immediate despatch on a next day delivery.
Our custom built transformer ranges are up to 60kVA 1ph and 500kVA 3ph. Beyond these sizes ETE has important
connections with some of Europe's leading manufacturers to enable us to quote against most specifications.

Contents summary

Transformers and
wound components

 Stock transformers

 Custom built transformers 1ph & 3ph

 Custom built transformers 3ph to 1ph

 Voltage transformers

 Autotransformers 1ph and 3ph

 PCB, toroidal and chassis mounted


transformers

 Enclosed transformers 1ph and 3ph

 Portable tool and site transformers

 Choke and reactors

 Variable auto transformers 1ph and


3ph both open and enclosed types

 ….and much more

Page 1 ETE ...........in complete control of power


SUB INDEX

ETE’s transformers and wound components cover a wide range of application criteria.
Our technical team is ready to assist in the selection and pricing of your requirements whether it is a ‘one off’ special or
an on-going regular requirement.
We use the latest innovations in materials and design features to enable us to offer optimum designs for all
specifications.

Contents detail

Transformers and wound components

Page 3 Stock range of SV (single voltage) and DV (dual voltage) single phase transformers from 25VA to 1kVA

Page 4 Stock range of MV (multi voltage) and WV (wide input voltage) single phase transformers from 50VA to 7.5kVA

Page 5 Custom built range of single phase transformers from 25VA to 7.5kVA, open or enclosed

Page 6 Custom built range of single phase dry type transformers from 10kVA to 75kVA, open or enclosed

Page 7 Custom built range of three phase transformers up to 75kVA, open or enclosed

Page 8 Custom built range of three phase transformers from 70kVA to 500kVA Class F and Class H

Page 9 Custom built range of V connected 3ph input to 1ph output transformers from 1.3kVA to >120kVA, open or enclosed

Page 10 Custom built 3ph transformers with special connection requirements, (Scott, Le Blanc, Zig-Zag, Hex phase and PST)

Page 11 Custom built three phase auto wound motor starting transformers, open or enclosed

Page 12 UL approved transformers from 40VA to 3kVA 1ph and 30VA to 30kVA 3ph

Page 13 Custom built range of single or three phase autotransformers, open or enclosed

Page 14 Custom built voltage transformers for measurement and instrumentation

Page 15 Custom built range of PCB mounted transformers and chassis mounted transformers

Page 16 Custom built range of DIN rail mounted, encapsulated transformers and Class II 1ph transformers

Page 17 Stock range of wall or floor mounted IP23 enclosed transformers with 110V sockets

Page 18 Custom built range of enclosed transformers with accessories

Page 19 Stock range of portable tool transformers 1kVA to 5kVA single phase and splitter boxes

Page 20 Stock range of portable site transformers from 8kVA to 10kVA 1ph/2ph and 10kVA to 30kVA 3ph

Page 21 Standard range of 3ph AC line reactors from 15A to 40A

Page 22 Standard range of 3ph AC line rectors from 70A to 830A

Page 23 Custom built AC output chokes and DC line chokes and custom built 1ph and 3ph chokes

Page 24 UL/CSA approval and transformers for Ex & IP65 enclosures plus heat loss data

Page 25 Single phase variable autotransformers (open or enclosed and bench mounted types)

Page 26 Three phase variable autotransformers (open or enclosed and bench mounted types)

Page 2 ETE ...........in complete control of power


SINGLE VOLTAGE (SV) & DUAL INPUT VOLTAGE (DV) STOCK RANGES
OF SINGLE PHASE TRANSFORMERS

Ex stock range with a next day delivery for the whole of the UK.

Single voltage (SV) & dual input voltage (DV) options.

Designed to EN 61558-1: Class E insulation.


High specification with IP20 touch proof terminals.
Class H varnish impregnation and core earth connection.
Ambient temperature range -10 deg C to +35 deg C.

Easy to install and with a DIN rail mounting option up to 150VA.


For a full range of enclosures (see accessories section).

Reference VA L W H FC FC FC Weight Enclosure Contactor information


rating (mm) L W diam (kg) reference Inr VA 95%V Inr VA 90%V

SV 25 25VA 66 60 76 50 40 5 0.70 EPH 1 or EPN 1 35 60


SV 50 50VA 75 65 88 56 45 5 1.00 EPH 1 or EPN 1 60 85
DV 50 50VA 75 71 88 56 51 5 1.20 EPH 1 or EPN 1 60 85
SV100 100VA 85 70 93 64 47 5 1.50 EPH 1 or EPN 1 150 225
DV 100 100VA 85 87 93 64 61 5 1.70 EPH 1 or EPN 1 150 225
SV 150 150VA 96 76 103 84 59 5 2.30 EPH 2 or EPN 1 250 400

DV 150 150VA 96 87 103 84 69 5 2.80 EPH 2 or EPN 1 250 400


SV 200 200VA 96 87 103 84 69 5 2.80 EPH 2 or EPN 1 350 600
DV 200 200VA 96 104 103 84 83 5 3.50 EPH 2 or EPN 1 350 600
SV & DV 250 250VA 120 88 120 90 70 5 3.90 EPH 3 or EPN 2 400 750

SV & DV 300 300VA 120 100 120 90 82 5 4.70 EPH 3 or EPN 2 650 1.0K
SV & DV 400 400VA 120 108 120 90 90 5 5.50 EPH 3 or EPN 2 900 1.5K
SV 500 500VA 120 120 120 90 102 5 6.20 EPH 3 or EPN 2 1.2K 1.75K
DV 500 500VA 135 105 125 105 88 5 6.20 EPN 3 1.2K 1.75K
SV & DV 750 750VA 150 108 145 122 84 6 7.60 EPN 3 2.2K 3.8K
SV & DV 1000 1.0kVA 150 125 145 122 101 6 9.80 EPN 3 3.0K 5.5K

Single voltage primary SV Dual voltage primary DV Single voltage secondary SV


input code input code output (for SV & DV ranges) code

0/240V 50/60Hz P4 0/240/415V 50/60Hz P6 0/110V S4

0/415V 50/60Hz P5 0/240V S5

0/24V S6

Stock units 25 50 100 150 200 250 300 400 500 750 1.0
available VA VA VA VA VA VA VA VA VA VA kVA

P4 S4 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

P4 S6 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

P5 S4 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

P5 S6 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

P6 S4 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

P6 S5 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

P6 S6 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

Page 3
MULTI VOLTAGE (MV) & WIDE INPUT VOLTAGE (WV) STOCK RANGES

Ex stock range with a next day delivery for the whole of the UK.

Multi voltage (MV) and wide input voltage range (WV) options.

Designed to EN 61558-1: Class E or Class F.


Class E insulation up to 3kVA, Class F insulation from 4kVA to 7.5kVA..
High specification with IP20 touch proof terminals.
Class H varnish impregnation and core earth connection .
Ambient temperature range -10 deg C to + 35 deg C.

Easy to install and with a DIN rail mounting option up to 150VA.


For a full range of enclosures (see accessories section).

Reference VA L W H FC FC FC Weight Enclosure Contactor information


rating (mm) L W diam (kg) reference Inr VA 95%V Inr VA 90%V

MV & WV 50 50VA 75 65 88 56 45 5 1.00 EPH 1 or EPN 1 60 85


MV & WV 100 100VA 85 70 93 64 47 5 1.50 EPH 1 or EPN 1 150 225
MV & WV 150 150VA 96 76 103 84 59 5 2.30 EPH 2 or EPN 1 250 400
MV & WV 200 200VA 96 87 103 84 69 5 2.80 EPH 2 or EPN 1 350 600
MV & WV 250 250VA 120 88 120 90 70 5 3.90 EPH 3 or EPN 2 400 750

MV & WV 300 300VA 120 100 120 90 82 5 4.70 EPH 3 or EPN 2 650 1.0K
MV & WV 400 400VA 120 108 120 90 90 5 5.50 EPH 3 or EPN 2 900 1.5K
MV & WV 500 500VA 120 120 120 90 102 5 6.20 EPH 3 or EPN 2 1.2K 1.75K
MV & WV 750 750VA 150 108 145 122 84 6 7.60 EPN 3 2.2K 3.8K
MV & WV 1000 1.0kVA 150 125 145 122 101 6 9.80 EPN 3 3.0K 5.5K
MV & WV 1500 1.5kVA 150 151 145 122 126 6 14.2 EPN 4 3.6K 6.2K
MV & WV 2000 2.0kVA 192 145 185 155 96 6 18.0 EPN 4 4.0K 7.5K
MV & WV 2500 2.5kVA 192 161 185 155 112 6 24.0 EPN 5 5.8K 9.0K
MV & WV 3000 3.0kVA 192 189 185 155 140 6 28.0 EPN 5 7.2K 10.2K
MV 4000 4.0kVA 245 190 230 114 & 162 133 8 36.0 EPN 6 9.5K 12.0K
MV 5000 5.0kVA 245 220 230 114 & 162 163 8 45.0 EPN 6 12K 15K

MV 6250 6.25kVA 245 250 230 114 & 162 193 8 58.0 EPN 7
MV 7500 7.5kVA 245 280 230 114 & 162 223 8 68.0 EPN 7

Multi-voltage MV Multi-voltage MV Wide input voltage - WV Wide input voltage - WV


primary input code secondary output code primary input code Secondary output code

10/0/220/240V 50/60Hz P1 0/55/110V S1 0/380/400/420/440/


-
P7 0/24V 0/24V S7
460/480V 50/60Hz
20/0/380/420V 50/60Hz P2 10/0/220/240V S2 0/500/550/600/690V P8 0/110/120V 0/110/120V S8
50/60Hz
0/120V 0/120V 50/60Hz P3 0/12V 0/12V S3

Stock units 50 100 150 200 250 300 400 500 750 1.0 1.5 2.0 2.5 3.0 4.0 5.0 6.25 7.5
available VA VA VA VA VA VA VA VA VA kVA kVA kVA kVA kVA kVA kVA kVA kVA
P1 S1 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

P1 S3 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

P2 S1 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

P2 S2 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

P2 S3 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

P3 S3 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

P7 S7 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

P7 S8 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

P8 S8 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

Page 4
CUSTOM BUILT RANGE OF SINGLE PHASE TRANSFORMERS
FROM 25VA TO 7.5KVA OPEN OR ENCLOSED

Fast delivery for urgent requirements.


Two day, within five working days and standard
quoted delivery options.

Designed to EN 60742 and EN 60076-1.

With either Class E or Class F insulation systems.


Ambient temperature range -10 to +40 deg C.

Enclosures available for all sizes from IP23 to IP55.

A comprehensive range of custom built single phase transformers designed specifically to customers own requirements.
Any quantity can be produced, from single units to regular call-off orders.
Sizes from 25VA to 4kVA (SE 25-SE 4000) are designed with Class E (120 deg C) materials with an additional option of
Class F (155 deg C) designs from 500VA to 7.5kVA (SF 500 to SF 7500).
All transformers are air cooled and are fully varnish impregnated with an aesthetically appealing gentian blue polyester
varnish. Terminals either IP20, DIN rail mounted, studs, copper tube crimps or bus bar (dependant on current ratings).

A full range of IP23 ventilated enclosures is available for all sizes as well as up to IP55.

Sizes from 25VA to 150VA can be fitted with ‘easy fit’ DIN rail fixing brackets if required (see accessories section).

Reference VA L W H FC FC FC Weight Enclosure


rating (mm) L W diam (kg) reference

SE 25 25VA 66(79E) 60 76 50 40 5 0.70 EPH1 or EPN 1


SE 50 50VA 75 65 88 56 45 5 1.00 EPH1 or EPN 1
SE 63 63VA 77 75 87 54 43 5 1.10 EPH1 or EPN 1
SE 80 80VA 75 71 88 56 51 5 1.20 EPH1 or EPN 1
SE 100 100VA 85 70 93 64 47 5 1.50 EPH1 or EPN 1
SE 150 150VA 96 76 103 84 59 5 2.30 EPH 2 or EPN 1
SE 200 200VA 96 87 103 84 69 5 2.80 EPH 2 or EPN 1
SE 250 250VA 120 88 120 90 70 5 3.90 EPH 3 or EPN 2
SE 300 300VA 120 100 120 90 82 5 4.70 EPH 3 or EPN 2
SE 400 & SF 500 400VA & 500VA 120 108 120 90 90 5 5.50 EPH 3 or EPN 2
SE 500 & SF 600 500VA & 600VA 120 120 120 90 102 5 6.20 EPH 3 or EPN 2

SE 600 & SF 750 600VA & 750VA 135 115 125 105 98 5 7.30 EPN 3

SE 750 & SF 1000 750VA & 1.0kVA 150 108 145 122 84 6 7.60 EPN 3

SE 1000 & SF 1250 1.0kVA & 1.25kVA 150 125 145 122 101 6 9.80 EPN 3
SE 1500 & SF 2000 1.5kVA & 2.0kVA 150 151 145 122 126 6 14.2 EPN 4

SE 2000 & SF 2500 2.0kVA & 2.5kVA 192 145 185 155 96 6 18.0 EPN 4
SE 2500 & SF 3000 2.5kVA & 3.0kVA 192 161 185 155 112 6 24.0 EPN 5

SE 3000 & SF 4000 3.0kVA & 4.0kVA 192 189 185 155 140 6 28.0 EPN 5
SE 4000 & SF 5000 4.0kVA & 5.0kVA 245 190 230 114 & 162 133 8 36.0 EPN 6

SF 5000 5.0kVA 245 220 230 114 & 162 163 8 45.0 EPN 6
SF 6250 6.25kVA 245 250 230 114 & 162 193 8 58.0 EPN 7
SF 7500 7.5kVA 245 280 230 114 & 162 223 8 68.0 EPN 7

Page 5
CUSTOM BUILT RANGE OF SINGLE PHASE TRANSFORMERS
FROM 10KVA TO 75KVA OPEN OR ENCLOSED

Designed to EN 60076-1.

Insulation systems: Class E ,F or H.

Insulation system up to 1.1kV, frequency 50/60Hz.

Ambient temperature range –5 deg C to +40 deg C.

Enclosures available for all sizes from IP23 to IP55.

A comprehensive range of custom built single phase transformers designed specifically to customers own requirements.
Any quantity can be produced, from single units to regular call-off orders.
Sizes from 10kVA to 50kVA (SE10000-SE50000) are designed with Class E (120 deg C) materials and sizes from
12.5kVA to 62.5kVA (SF12500- SF62500) are designed with Class F (155 deg C) materials.
Sizes SH35000 to SH75000 from 35kVA to 75kVA are designed with Class H materials (180 deg C).
All transformers are naturally air cooled and are fully varnish impregnated with an aesthetically appealing red polyester
varnish.
A range of enclosures to IP23 is available for all sizes as well as up to IP55.
Maximum voltage 1100V. Frequency 50Hz.

Reference Insulation VA L W H FC FC FC Weight Enclosure


class rating (mm) L W diam (kg) reference

SE10000 & SF12500 E and F 10kVA & 12.5kVA 320 230 500 240 140 10 80 ETS 1

SE12500 & SF15000 E and F 12.5kVA & 15kVA 320 250 500 240 160 10 95 ETS 1

SE15000 & SF20000 E and F 15kVA & 20kVA 320 290 500 240 200 10 110 ETS 1

SE 18000 & SF 22500 E and F 18kVA & 22.5kVA 320 320 500 240 230 10 130 ETS 2

SE 20000 & SF25000 E and F 20kVA & 25kVA 320 350 500 240 260 10 140 ETS 2

SE 25000 & SF30000 E and F 25kVA & 30kVA 400 375 700 350 180 15 160 ETS 3

SE30000 & SF37500 E and F 30kVA & 37.5kVA 400 400 700 350 205 15 185 ETS 3

SE40000 & SF50000 E and F 40kVA & 50kVA 400 450 700 350 230 15 210 ETS 3

SE50000 & SF62500 E and F 50kVA & 62.5kVA 400 500 700 350 280 15 230 ETS 3

SH35000 H 35kVA 400 375 700 350 180 15 160 ETS 3

SH45000 H 45kVA 400 400 700 350 205 15 185 ETS 3

SH60000 H 60kVA 400 450 700 350 230 15 210 ETS 3

SH75000 H 75kVA 400 500 700 350 280 15 230 ETS 3

Page 6
CUSTOM BUILT RANGE OF THREE PHASE TRANSFORMERS
OPEN OR ENCLOSED FROM 120VA TO 75KVA CLASS E & CLASS F

Designed to EN 60076-1.
Insulation systems: Class E or Class F.
Insulation system up to 1.1kV, frequency 50/60Hz.

Ambient temperature range –5 deg C to +40 deg C.

Terminals either: IP20, DIN rail mounted, studs, copper


tube crimps or bus bar (dependant on current ratings).

Enclosures available for all sizes from IP23 to IP55.

A comprehensive range of custom built three phase transformers designed specifically to customers own requirements.
Any quantity can be produced from single units to regular call-off orders.

Sizes from 120VA to 60kVA (TE120 to TE60000) are designed with Class E (120 deg C) materials with an additional
option of Class F (155 deg C) designs from 2.2kVA to 75kVA (TF2200 to TF75000).
All transformers are air cooled and are fully varnish impregnated with an aesthetically appealing red polyester varnish.
A full range of IP23 ventilated enclosures is available for all sizes as well as up to IP55.

Reference VA L W H FC FC FC Weight Enclosure


rating (mm) L W diam (kg) reference

TE 120 120VA 120 80 125 100 44 5 2 EPN 1

TE 200 200VA 120 90 125 100 54 5 3 EPN 1

TE 350 350VA 150 100 150 125 50 5 4 EPN 2

TE 500 500VA 150 115 150 125 65 5 6 EPN 2

TE 650 650VA 180 120 190 150 60 6 8 EPN 3

TE 900 900VA 180 140 190 150 80 6 10 EPN 3

TE 1300 1.3kVA 180 165 190 150 105 6 14 EPN 3

TE 1600 & TF 2200 1.6kVA & 2.2kVA 240 130 240 200 80 6 16 EPN 4

TE 2400 & TF 3200 2.4kVA & 3.2kVA 240 150 240 200 100 6 25 EPN 4

TE 3200 & TF 4000 3.2kVA & 4.0kVA 240 170 240 200 120 6 30 EPN 4

TE 4000 & TF 5200 4.0kVA & 5.2kVA 300 150 290 250 90 8 35 ETT 2

TE 5000 & TF 6500 5.0kVA & 6.5kVA 300 170 290 250 110 8 45 ETT 2

TE 6000 & TF 7800 6.0kVA & 7.8kVA 300 190 290 250 130 8 55 ETT 2

TE 7000 & TF 9000 7.0kVA & 9.0kVA 360 160 350 300 110 8 60 ETT 3

TE 8000 & TF 10000 8.0kVA & 10kVA 360 180 350 300 130 8 70 ETT 3

TE 10000 & TF 12500 10kVA & 12.5kVA 420 220 410 350 140 10 85 ETT 3

TE 12500 & TF 16000 12.5kVA & 16kVA 420 240 410 350 160 10 100 ETT 3

TE 16000 & TF 20000 16kVA & 20kVA 480 240 470 400 160 10 120 ETT 4

TE 20000 & TF 25000 20kVA & 25kVA 480 260 470 400 180 10 160 ETT 4

TE 25000 & TF 31500 25kVA & 31.5kVA 480 300 470 400 220 10 190 ETT 4

TE 31500 & TF 40000 31.5kVA & 40kVA 600 300 600 540 260 12 220 ETT 5

TE 40000 & TF 50000 40kVA & 50kVA 600 325 600 540 285 12 280 ETT 5

TE 50000 & TF 63000 50kVA & 63kVA 600 350 600 540 310 12 320 ETT 5

TE 60000 & TF 75000 60kVA & 75kVA 600 400 600 540 360 12 390 ETT 6

age 3

Page 7
CUSTOM BUILT RANGE OF THREE PHASE TRANSFORMERS
OPEN OR ENCLOSED FROM 70KVA TO 500KVA CLASS F AND CLASS H

Designed to EN 60076-1.
Insulation systems: Class F or H.
Insulation system up to 1.1kV, frequency 50/60Hz.

Ambient temperature range –5 deg C to +40 deg C.

Terminals either: IP20, DIN rail mounted, studs, copper


tube crimps or bus bar, dependant on current ratings.

Enclosures available for all sizes from IP23 to IP55.

A comprehensive range of custom built three phase transformers designed specifically to customers own
requirements. Any quantity can be produced from single units to regular call-off orders.

Sizes from 70kVA to 150kVA (TF 70000 to TF150000) are designed with Class F (155 deg C) materials with an
additional option of Class H (180 deg C) designs from 85kVA to 180kVA (TH 85000 to TH 180000).
All transformers are air cooled and are fully varnish impregnated with an aesthetically appealing red polyester varnish.
A full range of IP23 ventilated enclosures is available for all sizes as well as up to IP55.

Reference VA L W H FC FC FC Weight Enclosure


rating (mm) L W diam (kg) reference

TF 70000 & TH 85000 70kVA & 85kVA 700 365 850 240 285 20 380 ETT 8

TF 100000& TH 125000 100kVA & 125kVA 700 420 850 240 340 20 490 ETT 8

TF125000 & TH 150000 125kVA & 150kVA 700 470 850 240 390 20 590 ETT 8

TF 150000 & TH 180000 150kVA & 180kVA 700 520 850 240 440 20 680 ETT 8

Larger sizes from 175kVA to 450kVA (TGF 175K to TGF 450K)


are designed with Class F (155 deg C) materials.

An an additional option of Class H (180 deg C) designs from


225kVA to 500kVA (TGH 225K to TGH 500K) are also available.

All transformers are air cooled and are fully varnish impregnated
with an aesthetically appealing red polyester varnish.

A full range of IP23 ventilated enclosures is available for all sizes


as well as up to IP55.

Reference VA L W H FC FC FC Weight Enclosure


rating (mm) L W DIAM (kg) reference

TGF 175K & TGH 225K 175kVA & 225kVA 1000 700 900 560 350 24 660 ETT 8
TGF 200K & TGH 250K 200kVA & 250kVA 1000 725 900 560 375 24 770 ETT 8

TGF 225K & TGH 275K 225kVA & 275kVA 1000 750 900 560 400 24 880 ETT 8

TGF 250K & TGH 300K 250kVA & 300kVA 1000 775 900 560 425 24 990 ETT 8

TGF 300K & TGH 350K 300kVA & 350kVA 1000 825 900 560 475 24 1150 ETT 9

TGF 350K & TGH 400K 350kVA & 400kVA 1000 875 900 560 525 24 1300 ETT 9

TGF 400K & TGH 450K 400kVA & 450kVA 1000 925 900 560 575 24 1430 ETT 9

TGF 450K & TGH 500K 450kVA & 500kVA 1000 975 900 560 625 24 1550 ETT 9

Page 8
CUSTOM BUILT RANGE OF V CONNECTED 3PH INPUT TO 1PH OUTPUT TRANSFORMERS
FROM 1.3KVA TO 120KVA OPEN OR ENCLOSED

Designed to EN 60076-1.
Insulation systems: Class E or F.

Insulation system up to 1.1kV, frequency 50/60Hz.

Ambient temperature range –5 deg C to +40 deg C.

IP23 to IP55 enclosures available for all sizes.

3ph delta input to 1ph output.

A comprehensive range of custom built three phase input to single phase output transformers designed specifically to
customers own requirements.These units help to balance the loading of three phase supplies with two phases drawing
equal current. The third phase draws around twice the current of each of the other two phases.
Any quantity can be produced from single units to regular call-off orders.
Sizes from 1.3kVA to 56kVA (TSE 1300-TSE 56000) are designed with Class E (120 deg C) materials with an
additional option of Class F (155 deg C) designs from 1.8kVA to 120kVA (TSF 1800-TSF 120000).
All transformers are air cooled and are fully varnish impregnated with an aesthetically appealing red polyester varnish.
A full range of IP23 ventilated enclosures is available for all sizes as well as up to IP55.

Reference VA L W H FC FC FC Weight Enclosure


TSE Class E rating (mm) L W diam (kg) reference
TSF Class F
TSE 1300 & TSF 1800 1.3kVA & 1.8kVA 280 170 240 200 80 6 16 EPN 6
TSE 2000 & TSF 2600 2.0kVA & 2.6kVA 280 190 240 200 100 6 25 EPN 6
TSE 2600 & TSF 3200 2.6kVA & 3.2kVA 280 210 240 200 120 6 30 EPN 6
TSE 3200 & TSF 4200 3.2kVA & 4.2kVA 350 200 290 250 90 8 35 ETT 3
TSE 4000 & TSF 5200 4.0kVA & 5.2kVA 350 220 290 250 110 8 45 ETT 3

TSE 4800 & TSF 6200 4.8kVA & 6.2kVA 350 240 290 250 130 8 55 ETT 3
TSE 5600 & TSF 7200 5.6kVA & 7.2kVA 420 220 350 300 110 8 60 ETT 3
TSE 6400 & TSF 8000 6.4kVA & 8.0kVA 420 240 350 300 130 8 70 ETT 3
TSE 8000 & TSF 10000 8.0kVA & 10kVA 490 290 410 350 140 10 85 ETT 4
TSE 10000 & TSF 12500 10kVA & 12.5kVA 490 310 410 350 160 10 100 ETT 4
TSE 12500 & TSF 16000 12.5VA & 16kVA 560 320 470 400 160 10 120 ETT 3
TSE 16000 & TSF 20000 16kVA & 20kVA 560 340 470 400 180 10 160 ETT 4
TSE 20000 & TSF 25000 20kVA & 25kVA 560 380 470 400 220 10 190 ETT 4
TSE 25000 & TSF 32000 25kVA & 32kVA 700 400 600 540 260 12 220 ETT 5
TSE 32000 & TSF 40000 32kVA & 40kVA 700 425 600 540 285 12 280 ETT 5
TSE 40000 & TSF 50000 40kVA & 50kVA 700 450 600 540 310 12 320 ETT 5
TSE 56000 56kVA 820 485 850 480 285 20 380 ETT 8
TSF 60000 60kVA 700 500 600 540 360 12 390 ETT 6
TSF 80000 80kVA 820 520 850 480 340 20 490 ETT 8
TSF100000 100kVA 820 590 850 480 390 20 590 ETT 8
TSF 120000 120kVA 820 640 850 480 440 20 680 ETT 8

Page 9
CUSTOM BUILT 3PH TRANSFORMERS WITH SPECIAL CONNECTION REQUIREMENTS
WITH SCOTT, LE BLANC, ZIG-ZAG, HEX PHASE & PST OPTIONS.

Special connection requirements for 3ph transformers.


Insulation systems: Class E ,F or H dependant on size.

Insulation system up to 1.1kV, frequency 50/60Hz.

Scott connection for 3ph to 2ph or 2ph to 3ph.

Le Blanc connection for 3ph to 2ph.

Also Zig-Zag, Hex phase & PST connection options.

As well as offering standard 3ph to 3ph and 3ph to 1ph connection options for custom built transformers we can design
and manufacture transformers with other special connection requirements using either standard or non standard core
frames.

These connection configurations offer special solutions to some complex technical requirements such as phase
load balancing, earth grounding, harmonic suppression and phase displacement.

Our current kVA capacity is up to 400kVA using standard 3 phase vector groups for other requirements please contact
our sales department

SCOTT CONNECTED 3PH TO 2PH OR 2PH TO 3PH

There are applications where it in necessary to convert 3ph supplies to 2ph supplies and maintain a balanced load.
This configuration can be used where there is an existing 2ph system needing a new supply from a 3ph system.
The supply can be used to provide power for 2ph systems from a 3ph existing supply.
This configuration can be used to interlink a 2ph system to a 3ph system or visa versa.
If there are two single phase loads that are not connected in any way they can be supplied from this configuration and
the input load remains in balance.

LE BLANC CONNECTED 3PH TO 2PH

An alternative to Scott connected transformers for transforming 3ph to 2ph supplies.


This design method is an acceptable model. It is not as well known as the Scott connection method and therefore has
not gained the same popularity.

ZIG-ZAG CONNECTED 3PH CONNECTION

The delta zig-zag connection provides the same advantages as the conventional delta/star connection but it has some
other main advantages. It is less costly for grounding purposes, it is better for third harmonic suppression, it is better for
ground current isolation and there is no phase angle displacement.

HEX PHASE AND PHASE SHIFTING TRANSFORMERS (PST)

Hex phase and phase shifting transformers (PST) designs can be produced to customer requirements.

To discuss your specific needs for any of the above special connection requirements please contact our
technical sales department.

Page 10
CUSTOM BUILT 3 PHASE AUTO WOUND MOTOR STARTING TRANSFORMERS
OPEN OR ENCLOSED

Class E or Class F options.

2-6 starts per hour, 7-15 starts per hour


and 16-40 starts per hour.

Maximum run up/start time 45 seconds.


Minimum tapping 40%.

Open type or enclosed types from IP23 to IP55.

Two ranges of either Class E (120 deg C) or Class F (155 deg C) auto wound motor starting transformers. These units are
custom built and can be supplied as open or enclosed units. All transformers are air cooled and are fully varnish impregnated with
a class H varnish finish. Connections are via high current, non rotating stud terminals. These connections are shrouded with a
Perspex cover plate. Heat sensors or thermal cut outs can be fitted to each winding. A full range of ventilated enclosures is
available for all types.

Class E ref Class E HP kW Class E ref Class E HP kW Class E ref Class E HP kW Enclosure
2-6 starts size rating rating 7-15 starts size rating rating 16-40 starts size rating rating Reference
per hour per hour per hour
MS20/2-6/E TE2400 20 15 MS13/7-15/E TE2400 13 10 MS/9/16-40/E TE2400 9 7 EPN 4
MS27/2-6/E TE3200 27 20 MS20/7-15/E TE3200 20 15 MS/12/16-40/E TE3200 12 9 EPN 4
MS34/2-6/E TE4000 34 25 MS27/7-15/E TE4000 27 20 MS/13/16-40/E TE4000 13 10 ETT 2
MS40/2-6/E TE5000 40 30 MS34/7-15/E TE5000 34 25 MS/16/16-40/E TE5000 16 12 ETT 2
MS47/2-6/E TE6000 47 35 MS40/7-15/E TE6000 40 30 MS/18/16-40/E TE6000 18 13 ETT 2
MS60/2-6/E TE7000 60 45 MS47/7-15/E TE7000 47 35 MS/22/16-40/E TE7000 22 16 ETT 3
MS74/2-6/E TE8000 74 55 MS53/7-15/E TE8000 53 40 MS/27/16-40/E TE8000 27 20 ETT 3
MS107/2-6/E TE10000 107 80 MS67/7-15/E TE10000 67 50 MS/32/16-40/E TE10000 32 24 ETT 3
MS134/2-6/E TE12500 134 100 MS80/7-15/E TE12500 80 60 MS/40/16-40/E TE12500 40 30 ETT 3
MS175/2-6/E TE16000 175 130 MS107/7-15/E TE16000 107 80 MS/51/16-40/E TE16000 51 38 ETT 3
MS215/2-6/E TE20000 215 160 MS134/7-15/E TE20000 134 100 MS/65/16-40/E TE20000 65 48 ETT 4
MS270/2-6/E TE25000 270 200 MS160/7-15/E TE25000 160 120 MS/80/16-40/E TE25000 80 60 ETT 4
MS335/2-6/E TE31500 335 250 MS200/7-15/E TE31500 200 150 MS/100/16-40/E TE31500 100 75 ETT 5
MS430/2-6/E TE40000 430 320 MS255/7-15/E TE40000 255 190 MS/134/16-40/E TE40000 134 100 ETT 5
MS540/2-6/E TE50000 540 400 MS320/7-15/E TE50000 320 240 MS/160/16-40/E TE50000 160 120 ETT 5

Class F ref Class E HP kW Class F ref Class E HP kW Class F ref Class E HP kW Enclosure
2-6 starts size rating rating 7-15 starts size rating rating 16-40 starts size rating rating Reference
per hour per hour per hour
MS/134/2-6/F TE10000 134 100 MS/80/7-15/F TE10000 80 60 MS/40/16-40/F TE10000 40 30 ETT 3

MS/175/2-6/F TE12500 175 130 MS/107/7-15/ TE12500 107 80 MS/51/16-40/F TE12500 51 38 ETT 3
MS/215/2-6/F TE16000 215 160 MS/134/7-15/ TE16000 134 100 MS/65/16-40/F TE16000 65 48 ETT 3
MS/270/2-6/F TE20000 270 200 MS/160/7-15/ TE20000 160 120 MS/80/16-40/F TE20000 80 60 ETT 4

MS/335/2-6/F TE25000 335 250 MS/200/7-15/ TE25000 200 150 MS/100/16-40/F TE25000 100 75 ETT 4

MS/430/2-6/F TE31500 430 320 MS/255/7-15/ TE31500 255 190 MS/134/16-40/F TE31500 134 100 ETT 5

MS/540/2-6/F TE40000 540 400 MS/320/7-15/ TE40000 320 240 MS/160/16-40/F TE40000 160 120 ETT 5

MS/670/2-6/F TE50000 670 500 MS/400/7-15/ TE50000 400 300 MS/174/16-40/F TE50000 174 130 ETT 5

* To allow for increased height including stud terminals add 120mm


Information required when ordering
Line/line voltage, frequency and HP or KW rating, Class of insulation (E or F) and open or enclosed type.
Number of starts per hour and % voltage tappings, thermistor or auto reset cut out fitted and run up time if in excess of 45 seconds.

Page 11
UL APPROVED TRANSORMERS
FROM 40VA TO 3000VA 1PH AND FROM 200VA TO 30KVA 3PH

UL approved single phase control transformers.


From 40VA to 3000VA.

To UL 506/VDE 0570 and EN 61558 part 2-2/4.

Autotransformer versions:
VDE 0570/EN 60558 part 2-13 with index-A.

Insulation Class T 40/B.


IP rating IP20, Class I protection.
Frequency 50/60Hz.

IP23 to IP55 enclosures available for all sizes.

A comprehensive range of custom built UL approved single phase transformers designed specifically to customer
own requirements. Any quantity can be produced from single units to regular call-off orders.

The design is EI configuration and shell type construction. Both double wound (separate windings) and auto wound
(single winding) designs are available.
All transformers are air cooled and are fully vacuum varnish impregnated with an aesthetically appealing polyester
varnish.
They are chassis mounted with 100% duty cycle. Protection against accidental contact is to VBG 4.

A full range of IP23 ventilated enclosures is available for all sizes (as well as up to IP55).

For full size and performance data please contact our sales department.

UL approved three phase dry-type transformers.


From 200VA to 30kVA.

To UL 506/VDE 0570 and EN 61558 part 2-1.

Auto-transformer versions:
VDE 0570/EN 60558 part 2-13 with index-A.

Insulation Class T 40/B.


IP rating IP20, Class I protection.
Frequency 50/60Hz.

IP23 to IP55 enclosures available for all sizes

A comprehensive range of custom built UL approved three phase transformers designed specifically to customers own
requirements. Any quantity can be produced from single units to regular call-off orders.

The design is 3UI configuration and three limb core construction. Both double wound (vector group to be advised) and
auto wound (single winding with N brought out: Yna0) designs are available.
All transformers are air cooled and are fully vacuum varnish impregnated with an aesthetically appealing polyester
varnish.
They are chassis mounted with 100% duty cycle. Protection against accidental contact is to VBG 4.

A full range of IP23 ventilated enclosures is available for all sizes as well as up to IP55.

For full size and performance data please contact our sales department.

Page 12
OPEN OR ENCLOSED CUSTOM BUILT
SINGLE & THREE PHASE AUTOTRANSFORMERS

Custom built single phase autotransformers.


Either open or enclosed types.
Non safety isolating.
Insulation classes E or F.
Ideal where the output voltage is similar to the input voltage
and where safety isolation is not required.
Accessories include plugs and sockets, wheels, cooling fans,
indicator lamps, meters and mains isolator switches.
1ph auto

A comprehensive range of custom built single phase autotransformers in either open or enclosed types.

Major reductions in both size and cost can be achieved using autotransformers. They should only be used in applications where an
isolated output is not a safety requirement. Autotransformers are single winding units and offer no isolation between input and output
circuits. They are frequently used to adjust voltages for exported or imported machines or equipment.

Our sales department will calculate the size and cost reductions where autotransformers can be utilised.

Auto transformer types available Design and specification criteria

Single phase open type Up to 1000V and less than 500A naturally air cooled
Single phase enclosed in standard IP20 to IP23 Up to 1000V and less than 500A per phase naturally air cooled or fan cooled
Single phase enclosed Up to 1000V and less than 500A dependant on enclosure size
In IP65 or Ex enclosures Naturally air cooled utilising high grade core materials

Custom built three phase auto transformers.


Either open or enclosed types.
Non safety isolating.
Insulation classes E or F.
Ideal where output voltage (s) are similar to input voltage(s)
and where safety isolation is not required.
Accessories include plugs and sockets, wheels, cooling fans,
indicator lamps, meters and mains isolator switches.
3ph auto

A comprehensive range of custom built three phase autotransformers in either open or enclosed types.

Major reductions in both size and cost can be achieved using autotransformers. They should only be used in applications where an
isolated output is not a safety requirement. Autotransformers are single winding units and offer no isolation between the input and
the output circuits. They are frequently used to adjust voltages for exported or imported machines or equipment.

Our sales department will calculate the size and cost reductions where autotransformers can be utilised.

Auto transformer types available Design and specification criteria

Three phase open types Up to 1000V and less than 500A per phase, naturally air cooled

Three phase in IP23 enclosures Up to 1000V and less than 500A per phase, naturally air cooled or fan cooled

Three phase enclosed Up to 1000V and less than 500A per phase, dependant on enclosure size
In IP65 or Ex enclosures Naturally air cooled utilising high grade core materials

Page 13
CUSTOM BUILT VOLTAGE TRANSFORMERS
FOR MEASUREMENT AND INSTRUMENTATION

Single and 3 phase options.


Accuracy Classes 0.5,1 and 3.

To IEC 60044-2.

Class E insulation system.


Insulation system up to 1.1kV, frequency 50/60Hz.

Ambient temperature range –5 deg C to +40 deg C.


3ph VT

A range of single and three phase voltage transformers (VT) for measuring and instrumentation.

The designs are low loss with accuracy Classes of 0.5 (0.5%),1 (1%) and 3 (3%) with 3 phase units wound with zero phase angle
shift.
Class E insulation is used on all types. Designs up to 750V can be produced.

For other VT requirements please contact our sales department.

Reference Number of VA Accuracy Equivalent L W H FC FC FC Weight


phases rating (Class) frame (mm) L W diam (kg)

SVT 10/0.5 1ph 10VA 0.5 SE 150 96 80 103 84 59 5 2.30


SVT 20/0.5 1ph 20VA 0.5 SE 300 120 100 120 90 82 5 4.70
SVT 30/0.5 1ph 30VA 0.5 SE 500 120 120 120 90 102 5 6.20
SVT 50/0.5 1ph 50VA 0.5 SE 750 150 108 140 122 84 6 7.60
SVT 100/0.5 1ph 100VA 0.5 SE 1000 150 125 140 122 101 6 9.80
SVT 20/1 1ph 20VA 1 SE 200 96 90 103 84 69 5 2.80
SVT 30/1 1ph 30VA 1 SE 300 120 100 120 90 82 5 4.70
SVT 50/1 1ph 50VA 1 SE 500 120 120 120 90 102 5 6.20
SVT 100/1 1ph 100VA 1 SE 750 150 108 140 122 84 6 7.60
SVT 150/1 1ph 150VA 1 SE 1000 150 125 140 122 101 6 9.80
SVT 30/3 1ph 30VA 3 SE 150 96 80 103 84 59 5 2.30
SVT 50/3 1ph 50VA 3 SE 250 120 88 120 90 70 5 3.90
SVT 100/3 1ph 100VA 3 SE 500 120 120 120 90 102 5 6.20
SVT 200/3 1ph 200VA 3 SE 750 150 108 140 122 84 6 7.60

SVT 300/3 1ph 300VA 3 SE 1000 150 125 140 122 101 6 9.80

Reference Number of VA Accuracy Equivalent L W H FC FC FC Weight


phases rating (Class) frame (mm) L W diam (kg)

TVT 10/0.5 3ph 10VA 0.5 TE 200 120 90 125 100 54 5 3


TVT 15/0.5 3ph 15VA 0.5 TE 350 150 100 150 125 50 5 4
TVT 20/0.5 3ph 20VA 0.5 TE 500 150 115 150 125 65 5 6
TVT 30/0.5 3ph 30VA 0.5 TE 650 180 120 190 150 60 6 8
TVT 50/0.5 3ph 50VA 0.5 TE 900 180 140 190 150 80 6 10
TVT 100/0.5 3ph 100VA 0.5 TE 1300 180 165 190 150 105 6 14
TVT 15/1 3ph 15VA 1 TE 120 120 80 125 100 44 5 2
TVT 20/1 3ph 20VA 1 TE 200 120 90 125 100 54 5 3
TVT 30/1 3ph 30VA 1 TE 350 150 100 150 125 50 5 4
TVT 50/1 3ph 50VA 1 TE 900 180 140 190 150 80 6 10
TVT 100/1 3ph 100VA 1 TE 1300 180 165 190 150 105 6 14
TVT 30/3 3ph 30VA 3 TE 120 120 80 125 100 44 5 2
TVT 50/3 3ph 50VA 3 TE 200 120 90 125 100 54 5 3
TVT 100/3 3ph 100VA 3 TE 350 150 100 150 125 50 5 4

Page 14
CUSTOM BUILT RANGE OF PRINTED CIRCUIT BOARD MOUNTING TRANSFORMERS
AND CUSTOM BUILT RANGE OF CHASSIS MOUNTED TRANSFORMERS

Images are not to scale


Custom built range of PCB mounting transformers.

Ratings from 1VA to over 40VA 1ph.

Open and fully encapsulated types.

A comprehensive range of custom built printed circuit board


mounting transformers. All are designed and manufactured to
customers own requirements using top grade materials and
employing the most advanced production technology.
Power ratings start at less than 1VA and go up to over 40VA. Encapsulated PCB mounted
Standards include EN 60742 and EN 61558.
Fully encapsulated units are also available.

Description PCB pitch VA ratings


and type

Open type PCB mounted Using 5.08mm & From 1VA to


(Imperial) 7.62mm grid pitch 30VA
Open type PCB mounted Using 5.00mm grid From 1VA to
(Metric) pitch 40VA

Fully encapsulated conventional Using 5.00mm grid From 0.35VA


PCB mounted (Metric) pitch to 43.5VA
Fully encapsulated low profile Using 5.00mm grid From 3VA to
PCB mounted (Metric) pitch 30VA PCB mounted open type

Custom built range of chassis mounted transformers.

Ratings from 6VA to 90VA with 2 fixing wrap-over clamp.

Ratings from 25VA to 300VA with universal frames


or base clamps.

Open types with solder tag or amp tag connections.

Encapsulated type from 28VA to 120VA with


solder tags.

Chassis mounted with wrap over clamp


A comprehensive range of custom built chassis mounting
transformers. All are designed and manufactured to customers
own requirements using top grade materials and employing the
most advanced manufacturing technology. Ratings start at 6VA
and go up to 300VA.
Standards include EN 60742 and EN 61558.

Description Fixing type VA ratings


and type

Open type with Using two fixing wrap From 6VA


solder tags over clamping brackets to 90VA

Open type with Using four fixing universal From 25VA


solder tags frames or base clamps to 300VA

Open type with Using four fixing universal From 25VA


amp tags frames or base clamps to 300VA
Encapsulated Using multi fixing From 28VA
type moulded cases to 120VA Chassis mounted with base clamps

Page 15
CUSTOM BUILT RANGES OF DIN RAIL MOUNTED, ENCAPSULATED TRANSFORMERS
AND CLASS II SINGLE PHASE TRANSFORMERS

WZ Class II custom built units for DIN rail mounting.


Designed to EN 61558 2-4, 2-6: Class E insulation.
High specification Class II (no provision for earth).
Flying leads up to 10VA.
IP20 touch proof terminals or flying leads from 15VA to 50VA.
Encapsulated in flame retardant moulded housing.

Standard ambient temperature range -10 deg C to +35 deg C.


DIN rail mounting on TS35 x 7.5 and TS35 x 15 rails.

A new and unique range of DIN rail mounted, fully encapsulated, custom built single phase transformers meeting
Class II double insulated (with no provision for earth).
All transformers are enclosed in a black, high quality, flame retardant housing to UL 94.
Sizes from 7.5VA to 10VA have tri-rated flying leads and sizes from 15VA to 50VA can have either tri-rated flying leads
or IP20 touch proof terminals.

Reference VA W H H D D D Maximum number of


rating of case with DIN clip overall from rail from rail terminals
Input and output
with with
f.leads terminals
WZ 8 8VA 54 61 67 52 44 N/A Flying leads only
WZ 10 10VA 60 64 70 58 52 N/A Flying leads only
WZ 15 15VA 66 67 73 66 60 76 5 x 4mm sq x 2 rows
WZ 25 25VA 72 70 80 72 65 81 6 x 4mm sq x 2 rows
WZ 50 50VA 85 77 86 82 75 91 6 x 4mm sq x 2 rows

XM Class II custom built units


Designed to EN 61558 2-4, 2-6: Class F insulation.
High specification Class II (no provision for earth).
IP20 touch proof terminals, in a flame retardant, moulded
housing to UL 94VO.

Ambient temperature range -10 deg C to +35 deg C.

DIN rail mounting or chassis mounting up to 200VA.


Chassis mounting from 250VA to 300VA.

A new and unique range of custom built single phase transformers meeting Class II (with no provision for earth).
All transformers are enclosed in a grey, high quality, flame retardant moulded housing to UL94VO with terminals
protected to IP20.
Sizes from 50VA to 200VA can be DIN rail mounted and from 250VA to 300VA are chassis mounted.
Maximum voltage 750V. Frequency 50/60 Hz. Ambient temperature range -10 to +35 deg C.

Reference VA L W H FC FC FC Weight Maximum number of


terminals
XM 50 50VA 90 106 87 68.5 90 4.5 1.30 5 + 5
XM 75 75VA 90 106 87 68.5 90 4.5 1.50 5 + 5
XM 100 100VA 90 106 96 68.5 90 4.5 2.20 5 + 5
XM 125 125VA 90 106 106 68.5 90 4.5 2.60 5 + 5
XM 150 150VA 102 115.5 106 82 101.5 5.0 3.00 6 + 6
XM 175 175VA 102 115.5 116 82 101.5 5.0 3.40 6 + 6
XM 200 200VA 102 115.5 126 82 101.5 5.0 4.00 6 + 6
XM 250 250VA 126 136 117 96 121 5.5 4.60 7 + 7
XM 300 300VA 126 136 127 96 121 5.5 5.00 7 + 7

Page 16
STOCK RANGE OF WALL OR FLOOR MOUNTED
IP 23 ENCLOSED TRANSFORMERS WITH 110V SOCKET OUTLETS

For ‘hardwired’ workshop applications to supply 110V power tools.

Stock (MV) range of single or two phase enclosed transformers


with 110V centre tapped (55/0/55V) outputs.

Inputs 220~250V 1ph or 380~440V 2 wire (2ph) 50/60Hz.

Wall / floor mounted enclosures to IP23.

With or without MCB output protection, MCBs mounted behind


an IP65 accessible hinged cover .

A range of stock (MV) single phase or 2 wire (2ph) enclosed transformers for workshop applications. These are enclosed
in EPN style IP23 enclosures with 110V centre tap to Earth outputs. Output sockets to BS EN 60309-1 (BS4343) 110V 16A or
110V 32A sockets are fitted. Units are supplied with either output sockets only or with sockets and MCB protection. Input protec-
tion is via thermal overload on 220~250V versions or type D double pole MCB on 380~440V versions. All MCBs are mounted
behind an IP65 hinged cover.

Reference Input voltages Transformer rating: Sockets Enclosure Output protection


at 50/60Hz & continuous or reference DP Type D MCBs
input protection 20 minute tool rating and size in mm

WS 3000/2 P1S1 220/230/240/250V 1.5kVA continuous 2 x 110V 16A EPN 5 None


Thermal overload or 3kVA tool rated 350 L x 242 W x 353 H
WS 4000/3 P1S1 220/230/240/250V 2kVA continuous 3 x 110V 16A EPN 5 None
Thermal overload or 4kVA tool rated 350 L x 242 W x 353 H
WS 5000/2 P1S1 220/230/240/250V 2.5kVA continuous 1 x 110V 16A EPN 6 None
Thermal overload or 5kVA tool rated 1 x 110V 32A 384 L x 305 W x 454 H
WS 6000/3 P1S1 220/230/240/250V 3kVA continuous 2 x 110V 16A EPN 6 None
Thermal overload or 6kVA tool rated 1 x 110V 32A 384 L x 305 W x 454 H
WSP 3000/2 P1S1 220/230/240/250V 1.5kVA continuous 2 x 110V 16A EPN 5 1 x 16A
Thermal overload or 3kVA tool rated 350 L x 242 W x 353 H
WSP 4000/3 P1S1 220/230/240/250V 2kVA continuous 3 x 110V 16A EPN 5 1 x 16A
Thermal overload or 4kVA tool rated 350 L x 242 W x 353 H 1 x 32A
WSP 5000/2 P1S1 220/230/240/250V 2.5kVA continuous 1 x 110V 16A EPN 6 1 x 16A
Thermal overload or 5kVA tool rated 1 x 110V 32A 384 L x 305 W x 454 H 1 x 32A
WSP 6000/3 P1S1 220/230/240/250V 3kVA continuous 2 x 110V 16A EPN 6 1 x 16A
Thermal overload or 6kVA tool rated 1 x 110V 32A 384 L x 305 W x 454 H 1 x 32A

Reference Input voltages Transformer rating: Sockets Enclosure reference Output protection
at 50/60Hz & continuous or and size in mm DP Type D MCBs
input protection 20 minute tool rating

WS 3000/2 P2S1 380/400/420/440V 1.5kVA continuous 2 x 110V 16A EPN 5 None


20A DP MCB or 3kVA tool rated 350 L x 242 W x 353 H

WS 4000/3 P2S1 380/400/420/440V 2kVA continuous 3 x 110V 16A EPN 5 None


25A DP MCB or 4kVA tool rated 350 L x 242 W x 353 H
WS 5000/2 P2S1 380/400/420/440V 2.5kVA continuous 1 x 110V 16A EPN 6 None
32A DP MCB or 5kVA tool rated 1 x 110V 32A 384 L x 305 W x 454 H
WS 6000/3 P2S1 380/400/420/440V 3kVA continuous 2 x 110V 16A EPN 6 None
40A DP MCB or 6kVA tool rated 1 x 110V 32A 384 L x 305 W x 454 H
WSP 3000/2 P2S1 380/400/420/440V 1.5kVA continuous 2 x 110V 16A EPN 5 1 x 16A
20A DP MCB or 3kVA tool rated 350 L x 242 W x 353 H
WSP 4000/3 P2S1 380/400/420/440V 2kVA continuous 3 x 110V 16A EPN 5 1 x 16A
25A DP MCB or 4kVA tool rated 350 L x 242 W x 353 H 1 x 32A
WSP 5000/2 P2S1 380/400/420/440V 2.5kVA continuous 1 x 110V 16A EPN 6 1 x 16A
32A DP MCB or 5kVA tool rated 1 x 110V 32A 384 L x 305 W x 454 H 1 x 32A
WSP 6000/3 P2S1 380/400/420/440V 3kVA continuous 2 x 110V 16A EPN 6 1 x 16A
40A DP MCB or 6kVA tool rated 1 x 110V 32A 384 L x 305 W x 454 H 1 x 32A

Page 17
CUSTOM BUILT ENCLOSED TRANSFORMERS
WITH ACCESSORIES

For ‘hardwired’, portable or transportable applications.

Using standard stock (MV) range of single or two phase enclosed


transformers with 110V (55/0/55V) outputs or 240V outputs.

Inputs 230~240V 1ph or 400~415V 2 wire (2ph) 50/60Hz.

Wall / floor mounted enclosures from IP23 to IP55 with fan cooling.

With fuse or MCB protection for input and/or output and mounted
either internally or behind a IP65 accessible hinged cover.

A range of stock (MV) single phase or 2 wire (2ph) enclosed transformers for various applications. These are cased in a variety of
enclosures with 110V centre tap to Earth outputs or 240V outputs. Output sockets to BS 4343 can be fitted. Either fuse or MCB
protection can be fitted either internally inside the enclosure or on the front in an IP65 rated accessible cover. A basic example is
shown above. Other types are available.

Transformer rating Sockets Standard IP ratings Protection options

1kVA continuous or 2kVA tool rated 110V 16A IP23 to IP55 Input and or output, MCB or fuses

2kVA continuous or 4kVA tool rated 110V 16A IP23 to IP55 Input and or output, MCB or fuses

3kVA continuous or 6kVA tool rated 110V 16A,110V 32A IP23 to IP55 Input and or output, MCB or fuses

4kVA continuous or 8kVA tool rated 110V 16A,110V 32A IP23 to IP55 Input and or output, MCB or fuses

5kVA continuous or 10kVA tool rated 110V 16A,110V 32A IP23 to IP55 Input and or output, MCB or fuses

Custom built single and three phase enclosed transformers


with accessories.

Wall, floor or portable enclosures from IP20 to IP65 either standard


or custom built .

With fuse, MCB or thermal protection.

Accessories include: input or output plugs and sockets, wheels,


cooling fans, indicator lamps, meters and mains isolator switches.

A range of custom built single or three phase transformers with accessories. These can be enclosed in a variety of fixed or portable
enclosures from IP20 to IP65. Transformers with non-ventilated enclosures are designed with low loss cores and reduced losses in
the windings. Fuse, MCB or thermal protection can be incorporated.
A wide range of accessories can be fitted including input and output plugs and sockets to many international standards, wheels for
ease of movement, cooling fans, indicator lamps, a variety of metering and mains isolator switches.

Special requirements Typical options available

Enclosure type IP20 or IP23 fixed or portable types with or without fan ventilation. Up to IP65 fixed or portable

Input or output protection Fuse or MCB protection on input and/or outputs mounted inside or outside the enclosure

Indicator lamps LED: 22mm panel indicators in various colours


Metering Digital or analogue, including voltage and current

Mains isolators From single pole on/off switches to high current multi-pole isolator switches

Page 18
STOCK RANGE OF PORTABLE TOOL TRANSFORMERS
1KVA TO 5KVA SINGLE PHASE & SPLITTER BOXES

Transformer tool ratings


Images are not to scale

PT1000/2 1.0kVA with 2 x 110V 16A sockets.


PT1500/2 1.5kVA with 2 x 110V 16A sockets.
PT3300/2 3.3kVA with 2 x 110V 16A sockets.
PT5000/3 5.0kVA with 2 x 110V 16A sockets
and 1 x 110V 32A socket.

Reference 20 minute Continuous Input Weight


tool rating rating connection

PT1000/2 1.0kVA 700VA 2m cable 11kg PT 1500/2

and 13A plug


PT1500/2 1.5kVA 1.0kVA 2m cable 11kg

and 13A plug


PT3300/2 3.3kVA 1.5kVA 2m cable 17kg

and 13A plug


PT5000/3 5.0kVA 2.2kVA 2m cable 29kg

and 13A plug

Specification and construction

230~240V 50Hz input via 2m cable and 13 Amp UK plug.


110V output centre tapped to earth (55/0/55V).
To EN 61558-1: 2005 - CE marked.
Full thermal overload protection.
Output sockets to BS 4343: IP44. PT 5000/3
High impact polyester/glass enclosures 1-5kVA.

4 way splitter box

To give 4 way multiple outputs from a single 110V 16 Amp


transformer supply.

Output sockets to BS 4343.

Reference Output Input connections Weight


sockets

PTSB 4-2 4x 3m of arctic cable and 2 kg

110V 16 Amp 16 Amp 110V plug


PTSB 4-2

Page 3

Page 19
STOCK RANGE OF PORTABLE SITE TRANSFORMERS
FROM 8KVA TO 10KVA 1PH/2PH AND 10KVA TO 30KVA 3PH

Single phase site transformers (plus 415V 2 phase 2 wire)


Images are not to scale
SFS 8/10/6 8kVA continuous 10kVA intermittent
with 4 x 110V 16A sockets via 2 x 16A DP MCBs
and 2 x 110V 32A sockets via 2 x 32A DP MCBs.
SFS 10/12/6 10kVA continuous 12kVA intermittent
with 4 x 110V16A sockets via 2 x 16A DP MCBs
and 2 x 110V 32A sockets via 2 x 32A DP MCBs.
Reference Continuous 1 hour tool Weight Lifting
rating rating method
SFS 8/10/6 240V 8kVA 10kVA 70kg Fork lift
SFS 8/10/6 415V 8kVA 10kVA 70kg Fork lift
SFS 10/12/6 240V 10kVA 12kVA 85kg Fork lift
SFS 10/12/6 415V 10kVA 12kVA 85kg Fork lift

Specification and construction


220~250V 50Hz 1 ph input via 25mm cable entry (or)
380~440V 50Hz 2 ph input via 25mm cable entry.
110V output centre tapped to earth.
To EN 61558-1: 2005 - CE marked.
Full input and output MCB protection.
Output sockets to BS 4343: IP44.
SFS 8/10/6 240V
Three phase site transformers

TFS 10000/6 10kVA continuous


with 4 x 110V 16A sockets via 2 x 16A DP MCBs
and 2 x 110V 32A sockets via 2 x 32A DP MCBs.
TFS 15000/9 15kVA continuous
with 6 x 110V 16A sockets via 3 x 16A DP MCBs
and 3 x 110V 32A sockets via 3 x 32A DP MCBs.
TFS 20000/12 20kVA continuous
with 8 x 110V 16A sockets via 4 x 16A DP MCBs
and 4 x 110V 32A sockets via 4 x 32A DP MCBs.
TFS 30000/12 20kVA continuous
with 8 x 110V 16A sockets via 4 x 16A DP MCBs
and 4 x 110V 32A sockets via 4 x 32A DP MCBs.

Reference 1 hour Continuous Weight Lifting


tool rating rating method

TFS 10000/6 12.5kVA 10kVA 90kg Fork lift


TFS 15000/9 18.5kVA 15kVA 120kg Fork lift
TFS 20000/12 25kVA 20kVA 150kg Fork lift
TFS 25000/12 30kVA 25kVA 180kg Fork lift
TFS 30000/12 35kVA 30KVA 210kg Fork lift

Specification and construction


400~420V 50Hz 3ph delta connected input
via 25mm cable entry TFS 30000/12
110V ph/ph star connected output, with N taken to earth
To EN 60076-1 CE marked
WARNING: Lifting of all site transformers
Full input and output MCB protection
should be with a fork lift between the skids.
Output sockets to BS 4343: IP44
Weight dependant on size/rating 70~210kg.
Steel enclosure, epoxy powder coated

Page 20
STANDARD RANGE OF 3PH AC LINE REACTORS
FROM 15A TO 40A

Standard range of line reactors for AC motor controllers.


Ratings from 15A to 40A.

Fast delivery on standard listed designs.


Economical and compact sizes.
Class E insulation system. LR 50uH0015A

Easy to install.

A comprehensive range of standard design inductive reactors used in conjunction with AC motor controllers.
They are fitted to the input side of the drive and connected in with the incoming line.
They help mitigate harmonics and they are able to act as a buffer for surges and other transients. This will cause a typical volt drop
of between 2-4% of the nominal mains voltage. This can cause under voltage trips in the system where the input voltage is not
stable. Also this voltage drop can lower the DC bus voltage and negatively affect the output of the drive.

These chokes are supplied with a fast delivery and economical pricing.
The insulation class is Class E.

LR 50uH0015A has an inductance value of 50uH and a maximum current rating of 15A.
It is supplied with IP20 touch proof terminals with cable capacity of up to 4mm sq.

Reference Inductance L W H FC FC FC FC Weight


and current L W (min) W (max) diam (kg)
LR 50uH0015A 50uH 15A 120 65 136 100 35 50 6 1.60

LR 50uH0035A has an inductance value of 50uH and a maximum


current rating of 35A.
It is supplied with IP20 touch proof terminals with cable capacity of
up to 6mm sq.

LR 50uH0035A

Reference Inductance L W H FC FC FC FC Weight


and current L W (min) W (min) diam (kg)

LR 50uH0035A 50uH 35A 120 65 130 100 35 50 6 1.80

LR 50uH0040A has an inductance value of 50uH and a maximum


current rating of 40A.
It is supplied with DIN rail mounted terminals with cable capacity of
up to 10mm sq.

LR 50uH0040A

Reference Inductance L W H FC FC FC FC Weight


and current L W (min) W (min) diam (kg)
LR 50uH0040A 50uH 40A 65 88 160 100 35 50 6 2.00

Page 21
STANDARD RANGE OF 3PH AC LINE REACTORS
FROM 70A TO 830A

Standard range of line reactors for AC motor controllers.


Ratings from 15A to 40A.

Fast delivery on standard listed designs.


Economical and compact sizes.
Class E insulation system.
LR 50uH00180A

Easy to install.

A comprehensive range of standard design inductive reactors used in conjunction with AC motor controllers.
They are fitted to the input side of the drive and connected in with the incoming line.
They help mitigate harmonics and they are able to act as a buffer for surges and other transients. This will cause a typical volt drop of
between 2-4% of the nominal mains voltage. This can cause under voltage trips in the systems where the input voltage is not stable.
Also this voltage drop can lower the DC bus voltage and negatively affect the output of the drive.

These chokes are supplied with a fast delivery and economical pricing.
The insulation class is Class E.

The range LR 50uH0070A~LR 50uH0380A has an inductance value of 50uH and current ratings from 70A
to 380A.
There are 6 sizes and each are supplied with high current copper lug terminations.

Reference Inductance L W H FC FC FC FC Weight


and current Including L W (min) W (min) diam (kg)
terminals
LR 50uH0070A 50uH 70A 150 190 130 125 65 75 6 4.90

LR 50uH0110A 50uH 110A 180 210 150 150 70 90 8 8.40

LR 50uH0165A 50uH 165A 180 250 155 150 95 115 8 13.10

LR 50uH0180A 50uH 180A 240 260 210 200 170 190 8 13.20

LR 50uH0270A 50uH 270A 240 260 210 200 170 190 8 14.80

LR 50uH0380A 50uH 380A 240 260 210 200 170 190 8 15.10

The range LR 25uH0500A, LR 20uH0750A and LR 20uH0830A has


current ratings from 500A to 830A.
The 3 sizes are each are supplied with high conductivity copper
bus bar terminations pre-drilled as shown.

LR 20uH00725A

Reference Inductance L W H Bus FC FC FC FC Weight


and current Including bar L W (min) W (min) diam (kg)
terminals holes

LR 25uH0500A 25uH 500A 340 360 230 1 x 8mm 270 290 310 12 29.0

LR 20uH0725A 20uH 725A 420 430 240 1 x 12mm 300 355 380 15 51.0

LR 20uH0830A 20uH 830A 420 430 240 2 x 12mm 300 355 380 15 47.0

Page 22
CUSTOM BUILT AC OUTPUT LINE CHOKES AND DC LINE CHOKES
AND CUSTOM BUILT 1PH AND 3PH CHOKES

Custom built three phase output chokes for use with inverter drives.

Custom built DC link chokes.

Custom built 3ph reactors/chokes and DC chokes.

Designed to customer specification.


Using either our standard format
or to customers own drawings or requirements.
3ph output choke

Three phase output chokes are used with inverter drives with long cable runs. Cable run is the accumulated actual cable
length, connected to the inverter output terminals feeding either single or multiple motors.
They reduce both rising and falling times of output voltage edges and voltage peaks at the motor terminals.
Therefore, they protect the motor and decrease current leakages caused by the long motor cables.

Information required
Inductance, current rating, voltage and specific frequency requirements
Dimensions and any special constructional requirements

Custom built DC link chokes.


These DC link chokes are connected between the rectifier and the DC bus
and can be used to remove unwanted harmonics. They can be more or
less effective than AC line reactors depending on the harmonics in the line
and they add the necessary impedance for harmonic reduction without a
drop in voltage.
DC link chokes can also protect against current surges.

Units can be produced to customer drawings or customers own


requirements.

Information required

Inductance, current rating, and voltage

Dimensions and any special constructional requirements DC link choke

A comprehensive range of custom built AC reactors and DC chokes.

These reactors and chokes are custom built or can be designed to


customer drawings or requirements. Where dimensions are not critical
these units are designed around our standard frame sizes.

Alternatively units can be produced to customer drawings or customers


own requirements.

Information required

Inductance, current rating, voltage and frequency requirements


3ph line reactor
Dimensions and any special constructional requirements

Page 23
UL/CSA APPROVAL AND TRANSFORMERS FOR EX & IP65 ENCLOSURES
HEAT LOSS DATA FOR SINGLE PHASE TRANSFORMERS IN CLASSES F, E & A

UL/CSA design and approval plus ongoing compliance.

Heat loss data for Ex or IP65 enclosed transformers.

Losses for Class F (155 deg C) transformers.


Losses for Class E (120 deg C) transformers.
Losses for Class A (105 deg C) transformers
with frame size data
Losses for Ex or IP65 enclosed transformers
with frame size data.

UL/CSA designs with full approval can be produced to customer own requirements. Initial testing and approval and regular
inspection visits to ensure ongoing compliance is a service we can provide.

The heat loss data shown is important when transformers are fully enclosed or housed in confined control panel situations.
The data shown is provided to help design engineers select the correct transformer type and insulation type.

To allow transformers to be enclosed in Ex or IP65 rated cabinets high grade core materials can be used and core sizes adapted to
achieve lower temperature rises. Selection of enclosure must be based on the heat loss data provided.

Definitions and data


Insulation class Coding Temperature Maximum Maximum ambient
rating temperature rise temperature
Class F SF 155 deg C 115 deg C 35 deg C
Class E SE 120 deg C 85 deg C 35 deg C
Class A SA 105 deg C 70 deg C 35 deg C

High efficiency types for Ex & IP65 enclosure (Ex, IP65 ) for guidance only, for specific applications contact our sales department
C: Core losses are at nominal input voltage W: Winding losses (approximate) are at full load

Rating Losses Losses Frame Rating Losses Losses Frame Rating Losses Losses Frame Rating Losses Losses Frame
Class F C W size Class E C W size Class A C W size Ex d C W size
& IP65

30VA 5W 8W SE 25 25VA 5W 6W SE 25 20VA 4W 4W SE 25 20VA 0.6W 4W SE 25

60VA 6W 12W SE 50 50VA 6W 8W SE 50 40VA 5W 5W SE 50 40VA 0.8W 5W SE 50

120VA 7W 23W SE 100 100VA 7W 15W SE 100 80VA 6W 8W SE 100 80VA 1.0W 8W SE 100

180VA 10W 30W SE 150 150VA 10W 20W SE 150 125VA 8W 12W SE 150 125VA 1.5W 12W SE 150

225VA 13W 35W SE 200 200VA 13W 25W SE 200 150VA 10W 13W SE 200 150VA 2.0W 13W SE 200

280VA 18W 40W SE 250 250VA 18W 30W SE 250 200VA 13W 18W SE 250 200VA 3.2W 18W SE 250

300VA 24W 56W SE 250 300VA 24W 40W SE 300 250VA 18W 21W SE 300 250VA 4.0W 21W SE 300

400VA 26W 60W SE 300 400VA 26W 45W SE 400 300VA 21W 30W SE 400 300VA 5.0W 30W SE 400

500VA 28W 67W SE 400 500VA 28W 52W SE 500 400VA 23W 38W SE 500 400VA 6.0W 38W SE 500

600VA 32W 85W SE 500 600VA 32W 68W SE 600 500VA 25W 45W SE 600 500VA 6.0W 45W SE 600

700VA 35W 95W SE 600 750VA 35W 74W SE 750 600VA 28W 56W SE 750 600VA 6.5W 56W SE 750

1.0kVA 38W 110W SE 750 1.0kVA 38W 90W SE 1000 750VA 31W 65W SE 1000 750VA 6.0W 65W SE 1000

1.5kVA 53W 155W SE 1000 1.5kVA 53W 120W SE 1500 1.25kVA 45W 90W SE 1500 1.0kVA 11W 90W SE 1500

2.0kVA 62W 180W SE 1500 2.0kVA 62W 150W SE 2000 1.5kVA 55W 100W SE 2000 1.25kVA 13W 100W SE 2000

2.5kVA 77W 205W SE 2000 2.5kVA 77W 170W SE 2500 2.0kVA 63W 110W SE 2500 1.5kVA 15W 110W SE 2500

3.0kVA 103W 250W SE 2500 3.0kVA 103W 190W SE 3000 2.5kVA 85W 140W SE 3000 2.0kVA 21W 140W SE 3000
4.0kVA 116W 280W SE 3000 4.0kVA 116W 220W SE 4000 3.0kVA 95W 165W SE 4000 2.5kVA 24W 165W SE 4000
5.0kVA 160W 360W SE 4000 5.0kVA 160W 305W SE 5000 4.0kVA 125W 190W SE 5000 3.0kVA 33W 190W SE 5000
6.25kVA 200W 430W SE 5000 6.25kVA 200W 320W SE 6250 5.0kVA 160W 230W SE 6250 4.0kVA 42W 230W SE 6250
7.5kVA 248W 490W SE 6250 7.5kVA 248W 360W SE 7500 6.25kVA 200W 280W SE 7500 5.0kVA 51W 280W SE 7500

Page 24
SINGLE PHASE VARIABLE AUTO TRANSFORMERS
OPEN OR ENCLOSED AND BENCH MOUNTED TYPES

Open type single phase ranges from 1 amp to 28 amps.


* Stock items
Standard input 240V 50Hz, output 0….270V 50Hz 1ph.

High efficiency with no output voltage distortion.


Ambient temperature rating up to 45 deg C.

Long life, high quality wiper design.

Open or IP23 enclosed versions. 20F-1

A comprehensive range of single phase, variable autotransformers covering ratings from 1 amp to 28 amps.
Used for the variable control of voltages from 0V up to 270V 1ph with low power losses. Units can be supplied as either open or IP23
enclosed types with the option of double wound transfomers to give total isolation. Also units can be supplied to give a variable DC
output via a bridge rectifier. Motor drive options are also available. Larger units can be supplied by paralleling two or more stacked
versions and all types can be fully protected from overload and short circuits. They can also be fitted with full metering if required.
A comprehensive range of bench mounted units from 1 amp to 28 amps is also available.
The unique silver or nickle plated wiper path design gives high reliability and long life.
All windings are wound on high quality, low loss toroidal cores, giving efficiencies up to 98%.

Standard range Description Input Output Output Maximum L W H Shaft Shaft Weight
Reference Open type Voltage Voltage current VA diam L (kg)

1F-1 Panel mounted 1ph 240V 0….270V 1 Amp 270VA 85 105 100 4 25 1.60
2F-1* Panel mounted 1ph 240V 0….270V 2 Amps 540VA 110 140 125 7.5 31 2.90
3F-1 Panel mounted 1ph 240V 0….270V 3 Amps 810VA 110 140 135 7.5 31 3.30
4F-1 Panel mounted 1ph 240V 0….270V 4 Amps 1080VA 175 195 150 10 41 5.90
6F-1* Panel mounted 1ph 240V 0….270V 6 Amps 1620VA 175 195 165 10 41 6.80
8F-1 Panel mounted 1ph 240V 0….270V 8 Amps 2160VA 175 195 175 10 41 8.00
10F-1* Panel mounted 1ph 240V 0….270V 10 Amps 2700VA 175 195 185 10 41 9.00
15F-1 Panel mounted 1ph 240V 0….270V 15 Amps 4050VA 200 250 180 10 41 13.5
20F-1* Panel mounted 1ph 240V 0….270V 20 Amps 5400VA 200 250 190 10 41 15.0
28F-1* Panel mounted 1ph 240V 0….270V 28 Amps 7560VA 295 325 230 10 41 22.0

Bench mounted type single phase ranges from 1 amp to 28 amps.


* Stock items
Standard input 240V 50Hz, output 0….270V 50Hz 1ph.

High efficiency with no output voltage distortion.

Ambient temperature rating up to 45 deg C.

Long life, high quality wiper design.

20P-1

Standard range Description Input Output Output Maximum L W H Weight


Reference Bench mounted type Voltage Voltage current VA (kg)

1P-1 Test bench mounted-enclosed 1ph 240V 0….270V 1 Amp 270VA 125 130 130 2.3
2P-1* Test bench mounted-enclosed 1ph 240V 0….270V 2 Amps 540VA 130 130 155 4.2
3P-1 Test bench mounted-enclosed 1ph 240V 0….270V 3 Amps 810VA 130 130 155 4.6
4P-1 Test bench mounted-enclosed 1ph 240V 0….270V 4 Amps 1080VA 175 225 160 7.5
6P-1* Test bench mounted-enclosed 1ph 240V 0….270V 6 Amps 1620VA 175 225 160 8.0
8P-1 Test bench mounted-enclosed 1ph 240V 0….270V 8 Amps 2160VA 175 225 185 9.5
10P-1* Test bench mounted-enclosed 1ph 240V 0….270V 10 Amps 2700VA 175 225 185 10.0
15P-1 Test bench mounted-enclosed 1ph 240V 0….270V 15 Amps 4050VA 235 270 200 15.5
20P-1* Test bench mounted-enclosed 1ph 240V 0….270V 20 Amps 5400VA 235 270 200 18.0
28P-1 Test bench mounted-enclosed 1ph 240V 0….270V 28 Amps 7560VA 320 375 225 26.0

Page 25
THREE PHASE VARIABLE AUTO TRANSFORMERS
OPEN OR ENCLOSED AND BENCH MOUNTED TYPES

Open type three phase ranges from 1 amp to 28 amps per phase.
* Stock items
Standard input 415V 50Hz, output 0….470V 50Hz 3ph.

High efficiency with no output voltage distortion.


Ambient temperature rating up to 45 deg C.

Long life, high quality wiper design.

Open or IP23 enclosed versions. 20F-3

A comprehensive range of three phase variable autotransformers, covering ratings from 1 amp to 28 amps per phase. Used for the
variable control of voltages from 0V up to 470V 3ph, with low power losses. Units can be supplied as either open or IP23 enclosed
types, with the option of double wound transfomers to give total isolation. Also units can be supplied to give a variable DC output via a
bridge rectifier. Motor drive options are also available. Larger units can be supplied by paralleling two or more stacked versions and all
types can be fully protected from overload and short circuits. They can also be fitted with full metering if required.
A comprehensive range of bench mounted units from 1 amp to 28 amps per phase is also available.
The unique silver or nickle plated wiper path design gives high reliability and long life.
All windings are wound on high quality, low loss toroidal cores giving efficiencies up to 98%.

Standard range Description Input Output Output Maximum L W H Shaft Shaft Weight
Reference open type Voltage Voltage current VA diam L (kg)
per phase

1F-3 Floor mounted 3ph 415V 0…470V 1 Amp 814VA 85 105 265 4 30 5.40
2F-3* Floor mounted 3ph 415V 0…470V 2 Amps 1628VA 110 140 360 7.5 30 9.70
3F-3 Floor mounted 3ph 415V 0…470V 3 Amps 2442VA 110 140 360 7.5 30 10.9
4F-3 Floor mounted 3ph 415V 0…470V 4 Amps 3256VA 175 195 410 10 50 19.4
6F-3* Floor mounted 3ph 415V 0…470V 6 Amps 4884VA 175 195 410 10 50 22.0
8F-3 Floor mounted 3ph 415V 0…470V 8 Amps 6512VA 175 195 410 10 50 26.0
10F-3* Floor mounted 3ph 415V 0…470V 10 Amps 8140VA 175 195 410 10 50 29.1
15F-3 Floor mounted 3ph 415V 0…470V 15 Amps 12210VA 220 250 465 10 50 41.0
20F-3* Floor mounted 3ph 415V 0…470V 20 Amps 16280VA 220 250 465 10 50 49.0
28F-3 Floor mounted 3ph 415V 0…470V 28 Amps 22790VA 325 325 535 10 50 75.0

Bench mounted type three phase ranges from 1 amp to 28 amps.

Standard input 415V 50Hz, output 0….470V 50Hz 3ph.


* Stock items
High efficiency with no output voltage distortion.

Ambient temperature rating up to 45 deg C.

Long life, high quality wiper design.


15P-3

Standard range Description Input Output Output Maximum L W H Weight


Reference Bench mounted type Voltage Voltage current VA (kg)
per phase
1P-3 Fully enclosed free standing 3ph 415V 0…470V 1 Amp 814VA 120 150 270 7.3
2P-3* Fully enclosed free standing 3ph 415V 0…470V 2 Amps 1628VA 170 145 430 13.0
3P-3 Fully enclosed free standing 3ph 415V 0…470V 3 Amps 2442VA 170 145 430 13.5
4P-3 Fully enclosed free standing 3ph 415V 0…470V 4 Amps 3256VA 190 245 520 27.5
6P-3* Fully enclosed free standing 3ph 415V 0…470V 6 Amps 4884VA 190 245 520 29.0
8P-3 Fully enclosed free standing 3ph 415V 0…470V 8 Amps 6512VA 190 245 520 32.0
10P-3* Fully enclosed free standing 3ph 415V 0…470V 10 Amps 8140VA 190 245 520 34.0
15P-3 Fully enclosed free standing 3ph 415V 0…470V 15 Amps 12210VA 240 310 560 51.5
20P-3* Fully enclosed free standing 3ph 415V 0…470V 20 Amps 16280VA 240 310 560 59.0
28P-3 Fully enclosed free standing 3ph 415V 0…470V 28 Amps 22790VA 240 400 630 86.0

Page 26
RED SECTION

ETE is a leading UK transformer manufacturer as well as a key national distributor of a variety of power electronics
for the controls and automation markets.
Our ranges of power supplies are one of the most comprehensive in the whole UK with units available from stock on
a next day delivery. In addition we can offer ranges of EMC filters, UPS units, comprehensive ranges of industrial
battery chargers and much more.

Contents summary

Power
Electronics

Approved UK
national distributor

 AC/DC power supplies for DIN rail mounting from


10 Watts~960 Watts in 5V, 12V, 15V, 24V & 48V DC

 DC/DC converters

 Battery chargers with UPS function for DIN rail mounting

 Battery chargers for DIN rail mounting

 Chassis mounted switched mode PSUs from 15W~5kW

 Linear power supplies for 24V DC

 Constant voltage transformers 1ph and 3ph

 Uninterruptible Power Supplies from 400VA~2kVA

 DC-UPS modules

 EMC filters 1ph and 3ph

 ….and much more

Page 27 ETE ...........in complete control of power


SUB INDEX

ETE’s power products cover a wide range of application criteria.


Our technical team is ready to assist in the selection and pricing of your requirements whatever the quantity.
We represent some of the worlds key power product manufacturers, many of which are exclusive to ETE.
Many product ranges are available ex stock, either direct or via our extensive network of UK distributors.

Contents detail

Power Electronics
Page 29 Stock range of MDR miniature AC to DC switched-mode power supplies, from 10W to 100W in various voltages

Page 30 Stock range of DR Class II AC to DC switched-mode power supplies, from 15W to 100W in various voltages

Page 31 Stock range of DR, DRP, DRH, DRT single output AC to DC switched-mode power supplies, from 75W to 960W in various voltages

Page 32 Stock ranges of DR 45W moulded case and high efficiency, SDR slim series 75W to 960W PSUs in various voltages

Page 33 Stock range of WDR wide input of AC to DC switched-mode power supplies 120W to 480W and redundancy and UPS modules

Page 34 New stock ranges of EDR, from 75W to 150W, and NDR, from 75W to 480W, AC to DC DIN rail power supplies

Page 35 New TDR 960W 3ph AC to DC switched-mode power supplies and DRA series 40W & 60W with adjustable output currents

Page 36 RS series of low cost, miniature chassis mounted switched-mode power supplies from 15W to 150W

Page 37 RSP series of low cost, chassis mounted switched-mode power supplies with PFC from 75W to 150W

Page 38 RSP series of low cost, chassis mounted switched-mode power supplies with PFC from 200W to 320W

Page 39 RSP series of enclosed chassis mounted switched-mode power supplies with PFC from 500W to 1000W & PSP 600W

Page 40 RSP series of enclosed chassis mounted switched-mode power supplies with PFC from 1500W to 3000W & RST 5000W series

Page 41 HLG series of harsh environments single output switched-mode power supplies from 40W to 60W

Page 42 HLG series of harsh environments single output switched-mode power supplies from 80W to 120W

Page 43 HLG series of harsh environments single output switched-mode power supplies from 150W to 240W

Page 44 HLG series of harsh environments single output switched-mode power supplies from 320W to 600W & HEP 600W

Page 45 DC/DC converters from 15W to 1000W with single 24V DC output

Page 46 DRC series of DIN rail mounted power supplies from 40W to 100W and fully enclosed security series

Page 47 Stock series of single output battery chargers with UPS function and all in one battery chargers with continuity backup function

Page 48 AC/DC and DC/DC converters and AC/DC battery chargers from 36W to 480W

Page 49 Unregulated and smoothed 24V DC power supplies with single and 3 phase inputs

Page 50 Stock range of single output 24V DC switched-mode power supplies with 1ph and 3ph inputs and special optional functions

Page 51 Constant voltage transformers (CVT) from 100VA to 15kVA 1ph and 9kVA to 45kVA 3ph

Page 52 Line interactive uninterruptible power supplies (UPS) from 400VA to 2000VA

Page 53 C-TEC series of DC buffer modules without batteries using ultra capacitor technology

Page 54 AKKUTEC range of online DC-UPS from 48W to 960W

Page 55 Stock ranges of single phase EMC filters from 5A to 65A

Page 56 Stock ranges of three phase EMC filters from 7A to 2500A

Page 28 ETE ...........in complete control of power


STOCK RANGE OF MINIATURE AC TO DC DIN RAIL MOUNTED
SWITCHED-MODE POWER SUPPLIES FROM 10W TO 100W IN VARIOUS VOLTAGES

Competitive prices and ex stock delivery.

High quality, approved to EN, UL and CE.


From 10 Watts up to 100 Watts.

Narrow profile optimising the space on the DIN rail.

Wide input range 85V~264V AC 1 phase.

Output voltages of 5V,12V,15V, 24V and 48V DC.

EMC standards EN 55022 Class B, EN 61000-3-2,3 (All),


EN 55024.

A high quality, highly cost-effective range of DIN rail mounted switched-mode power supplies from 10W up to 100W.
These units are a special narrow profile, they optimise the space on the DIN rail and are ex stock. All units are available in a variety of
output voltages, they are approved to EN and UL and are CE marked.
They have universal inputs and all units are fully protected against overload, short circuit and over voltage and have an LED
‘power on’ indicator.
Each unit is subjected to a 100% full load burn-in test. All units have a DC output adjuster to increase the rated output voltage.
Safety standards are to EN and UL requirements, CE marking is standard and they have a full 3 years warranty.
The ambient temperature range from –15 to +50 deg C.

Reference Watts Input voltage Output voltage Load & Line Ripple & Efficiency Dimensions (mm)
and current regulation noise LxDxH

MDR-10-05 10 Watt 85~264V AC 1ph 120~370V DC 5V DC 2.0A +/- 1% 80mV 77% 22.5 x 100 x 90

MDR-10-12 10 Watt 85~264V AC 1ph 120~370V DC 12V DC 0.8A +/- 1% 120mV 81% 22.5 x 100 x 90

MDR-10-15 10 Watt 85~264V AC 1ph 120~370V DC 15V DC 0.6A +/- 1% 120mV 81% 22.5 x 100 x 90

MDR-10-24 10 Watt 85~264V AC 1ph 120~370V DC 24V DC 0.4A +/- 1% 150mV 84% 22.5 x 100 x 90

MDR-20-05 20 Watt 85~264V AC 1ph 120~370V DC 5V DC 3.0A +/- 2% 80mV 76% 22.5 x 100 x 90

MDR-20-12 20 Watt 85~264V AC 1ph 120~370V DC 12V DC 1.67A +/- 1% 120mV 80% 22.5 x 100 x 90

MDR-20-15 20 Watt 85~264V AC 1ph 120~370V DC 15V DC 1.34A +/- 1% 120mV 81% 22.5 x 100 x 90

MDR-20-24 20 Watt 85~264V AC 1ph 120~370V DC 24V DC 1.0A +/- 1% 150mV 84% 22.5 x 100 x 90

MDR-40-05 40 Watt 85~264V AC 1ph 120~370V DC 5V DC 6.0A +/- 2% 80mV 78% 40 x 100 x 90

MDR-40-12 40 Watt 85~264V AC 1ph 120~370V DC 12V DC 3.33A +/- 1% 120mV 86% 40 x 100 x 90

MDR-40-24 40 Watt 85~264V AC 1ph 120~370V DC 24V DC 1.7A +/- 1% 150mV 88% 40 x 100 x 90

MDR-40-48 40 Watt 85~264V AC 1ph 120~370V DC 48V DC 0.83A +/- 1% 200mV 88% 40 x 100 x 90

MDR-60-05 60 Watt 85~264V AC 1ph 120~370V DC 5V DC 10.0A +/- 1.5% 80mV 78% 40 x 100 x 90

MDR-60-12 60 Watt 85~264V AC 1ph 120~370V DC 12V DC 5.0A +/- 1% 120mV 86% 40 x 100 x 90

MDR-60-24 60 Watt 85~264V AC 1ph 120~370V DC 24V DC 2.5A +/- 1% 150mV 88% 40 x 100 x 90

MDR-60-48 60 Watt 85~264V AC 1ph 120~370V DC 48V DC 1.25A +/- 1% 200mV 87% 40 x 100 x 90

MDR-100-12 100 Watt 85~264V AC 1ph 120~370V DC 12V DC 7.5A +/- 1% 120mV 85% 55 x 100 x 90

MDR-100-24 100 Watt 85~264V AC 1ph 120~370V DC 24V DC 4.0A +/- 1% 150mV 86% 55 x 100 x 90

MDR-100-48 100 Watt 85~264V AC 1ph 120~370V DC 48V DC 2.0A +/- 1% 200mV 88% 55 x 100 x 90

Page 29
STOCK RANGE OF CLASS II SINGLE OUTPUT AC TO DC DIN RAIL MOUNTED
SWITCHED-MODE POWER SUPPLIES FROM 15W TO 100W IN VARIOUS VOLTAGES

Competitive prices and ex stock deliveries.

To isolation Class II.


High quality, approved to UL, CUL,TUV, CB and CE.

From 15 Watt to 100 Watt.

Input range from 85V up to 264V AC 1 phase.

Output voltages of 5V, 12V, 15V and 24V.

EMC standards EN 55024 Class B, EN 61000-2,3,4,5,6,8,11,


EN 61000-6-2, EN 61204-3 heavy industry level, criteria A.

A high quality, highly cost-effective, ex stock range of DIN rail mounted switched-mode power supplies from 15W to 100W.
They are designed to isolation Class II with no provision for earth.
These units are available in a variety of output voltages, they are fully approved to UL, CUL, TUV, CB and are CE marked.
They have universal inputs of 85~264V AC 1ph in 15W, 30W, 60W and 100W. All units are fully protected against overload, short
circuit, over voltage and over temperature and have an LED ‘power on’ indicator.
Each unit is subjected to a 100% full load burn-in test.
EMC standards are as stated above and all units have a DC output adjuster to provide +10% of rated output voltage.
All units have a full 3 years warranty and are designed for an ambient temperature range from 0 to +45 deg C.

Reference Watts Input voltage Output Output V Ripple & Efficiency Dimensions (mm)
range voltage tolerance noise L x D x H mm

DR-15-05 15 Watt 85~264V AC 1ph 120~370V DC 5V DC 2.4A +/- 2% 80mV 77% 25 x 56 x 93

DR-15-12 15 Watt 85~264V AC 1ph 120~370V DC 12V DC 1.25A +/- 1% 120mV 84% 25 x 56 x 93

DR-15-15 15 Watt 85~264V AC 1ph 120~370V DC 15V DC 1.0A +/- 1% 120mV 83% 25 x 56 x 93

DR-15-24 15 Watt 85~264V AC 1ph 120~370V DC 24V DC 0.63A +/- 1% 150mV 85% 25 x 56 x 93

DR-30-05 30 Watt 85~264V AC 1ph 120~370V DC 5V DC 3.0A +/- 2% 80mV 74% 78 x 56 x 93

DR-30-12 30 Watt 85~264V AC 1ph 120~370V DC 12V DC 2.0A +/- 1% 120mV 81% 78 x 56 x 93

DR-30-15 30 Watt 85~264V AC 1ph 120~370V DC 15V DC 2.0A +/- 1% 120mV 82% 78 x 56 x 93

DR-30-24 30 Watt 85~264V AC 1ph 120~370V DC 24V DC 1.5A +/- 1% 150mV 83% 78 x 56 x 93

DR-60-05 60 Watt 85~264V AC 1ph 120~370V DC 5V DC 6.5A +/- 2% 80mV 76% 78 x 56 x 93

DR-60-12 60 Watt 85~264V AC 1ph 120~370V DC 12V DC 4.5A +/- 1% 120mV 83% 78 x 56 x 93

DR-60-15 60 Watt 85~264V AC 1ph 120~370V DC 15V DC 4.0A +/- 1% 120mV 84% 78 x 56 x 93

DR-60-24 60 Watt 85~264V AC 1ph 120~370V DC 24V DC 2.5A +/- 1% 150mV 86% 78 x 56 x 93

DR-100-12 100 Watt 85~264V AC 1ph 120~370V DC 12V DC 7.5A +/- 1% 120mV 84% 100 x 56 x 93

DR-100-15 100 Watt 85~264V AC 1ph 120~370V DC 15V DC 6.5A +/- 1% 120mV 85% 100 x 56 x 93

DR-100-24 100 Watt 85~264V AC 1ph 120~370V DC 24V DC 4.2A +/- 1% 150mV 86% 100 x 56 x 93

Page 30
STOCK RANGE OF SINGLE OUTPUT AC TO DC DIN RAIL MOUNTED
SWITCHED-MODE POWER SUPPLIES FROM 75W TO 960W IN VARIOUS VOLTAGES

Single phase inputs.


Competitive prices and ex stock deliveries.
High quality, approved to UL,CUL,TUV,CB and CE.

From 75 Watt to 480 Watt 1ph with a wide input range.

Output voltages of 12V, 24V and 48V DC.

EMC standards EN 55022 Class B,EN 61000-3-2,3,


EN 61000-4-2,3,4,5,6,8,11 and EN 61000-6-2.

A high quality, highly cost-effective, ex stock range of DIN rail mounted switched-mode power supplies from 75W to 960W.
These units are available in a variety of output voltages, they are fully approved to UL, CUL, TUV, CB and are CE marked. They have
universal inputs of 85~264V AC 1ph in 75W,240W, the 120W range is from 88~264V AC 1ph selected by a switch and the 480W units
have inputs of either 180~264V AC 1ph or 90~264V AC 1ph. Three phase units are available in 240W, 480W and 960W with an input
range of 340~550V AC 3ph. The DRH-120 is a 2 wire 340~550V AC 1ph input for low power applications. All units are fully protected
against overload, short circuit, over voltage and over temperature and have an LED ‘power on’ indicator. Each unit is subjected to a
100% full load burn-in test. EMC standards are as stated above and all units have a DC output adjuster to provide +10% of rated
output voltage. All units have a full 3 years warranty and are designed for an ambient temperature range from 0 to +45 deg C.

Reference Watts Input voltage Output voltage Output V Ripple & Efficiency Dimensions
range and current tolerance noise L x D x H mm

DR-75-12 75 Watt 85~264V AC 1ph 120~370V DC 12V DC 6.3A +/- 2% 100mV 76% 55.5 x 100 x 25.2
DR-75-24 75 Watt 85~264V AC 1ph 120~370V DC 24V DC 3.2A +/- 1% 150mV 80% 55.5 x 100 x 125.2
DR-75-48 75 Watt 85~264V AC 1ph 120~370V DC 48V DC 1.6A +/- 1% 240mV 81% 55.5 x 100 x 125.2
DR-120-12 120 Watt 85~264V AC 1ph 120~370V DC 12V DC 10A +/- 2% 80mV 80% 65.5 x 100 x 125.2
DR-120-24 120 Watt 88~132V/176~264V AC 1ph 248~370V DC 24V DC 5.0A +/- 1% 80mV 84% 65.5 x 100 x 125.2
DR-120-48 120 Watt 88~132V/176~264V AC 1ph 248~370V DC 48V DC 2.5A +/- 1% 100mV 85% 65.5 x 100 x 125.2
DRP-240-24 240 Watt 85~264V AC 1ph 120~370V DC 24V DC 10A +/- 1% 80mV 84% 125.5 x 100 x 125.2
DRP-240-48 240 Watt 85~264V AC 1ph 120~370V DC 48V DC 5.0A +/- 1% 150mV 85% 125.5 x 100 x 125.2
DRP-480-24 480 Watt 180~264V AC 1ph 250~370V DC 24V DC 20A +/- 1% 120mV 89% 227 x 100 x 125.2
DRP-480S-24 480 Watt 90~132V/180~264V AC 1ph 254~370V DC 24V DC 20A +/- 1% 120mV 89% 227 x 100 x 125.2
DRP-480S-48 480 Watt 90~132V/180~264V AC 1ph 254~370V DC 48V DC 10A +/- 1% 120mV 89% 227 x 100 x 125.2

2 phase and 3 phase inputs


Competitive prices and ex stock deliveries
High quality, approved to UL,CUL,TUV,CB and CE

From 240 Watt to 960 Watt with an input range from


340~550V three phase
120 Watt units with an input range of 340~550V 2ph

Output voltages of 12V, 24V and 48V DC

EMC standards EN 55022 class B, EN 61000-3-2,3


EN 61000-4-2,3,4,5,6,8,11 and EN 61000-6-2
Reference Watts Input voltage Output voltage Output V Ripple & Efficiency Dimensions
range and current tolerance noise L x D x H mm

DRH-120-24 120 Watt 340~550V AC 2ph 480~780V DC 24V DC 5.0A +/- 1% 80mV 85% 65.5 x 100 x 125.2
DRH-120-48 120 Watt 340~550V AC 2ph 480~780V DC 48V DC 2.5A +/- 1% 80mV 85% 65.5 x 100 x 125.2
DRT-240-24 240 Watt 340~550V AC 3ph 480~780V DC 24V DC 10A +/- 1% 80mV 89% 125.5 x 100 x 125.2
DRT-240-48 240 Watt 340~550V AC 3ph 480~780V DC 48V DC 5A +/- 1% 80mV 89% 125.5 x 100 x 125.2
DRT-480-24 480 Watt 340~550V AC 3ph 480~780V DC 24V DC 20A +/- 1% 80mV 89% 227 x 100 x 125.2
DRT-480-48 480 Watt 340~550V AC 3ph 480~780V DC 48V DC 10A +/- 1% 80mV 89% 227 x 100 x 125.2
DRT-960-24 960 Watt 340~550V AC 3ph 24V DC 40A +/- 1% 80mV 91% 275 x 100 x 125.2
DRT-960-48 960 Watt 340~550V AC 3ph 48V DC 20A +/- 1% 80mV 92% 275 x 100 x 125.2

Page 31
STOCK RANGE OF AC TO DC DIN RAIL MOUNTED SWITCHED-MODE POWER SUPPLIES
IN 45W MOULDED CASE & HIGH EFFICIENCY SLIM SERIES 75W TO 960W IN VARIOUS VOLTAGES

Competitive prices.
High quality, approved to EN, UL and CE.

Moulded case in 45 Watt rating.


Wide input range 85V~240V AC 1 phase.
Output voltages of 5V,12V,15V and 24V DC.

EMC standards EN 55022 Class B, EN 61000-3-2,3 (All)


and EN55024.
Ambient temperature range 0~45 deg C.

A high quality, highly cost effective range of DIN rail mounted switched-mode 45 Watt power supplies, in moulded a case.
All these types are ex stock. All units are available in a variety of output voltages, they are approved to EN, UL and are CE marked.
They have universal inputs and all units are fully protected against overload, short circuit and over voltage and have an LED ‘power
on’ indicator.
Each unit is subjected to a 100% full load burn-in test. All units have a DC output adjuster to increase the rated output voltage.
Safety standards are to EN and UL requirements and CE marking is standard. All units have a full 3 years warranty.

Reference Watts Input voltage Output voltage Load & Line Ripple & Efficiency Dimensions
and current regulation noise L x D x H mm
DR-45-05 45 Watt 85~264V AC 1ph 120~370V DC 5V DC 5.0A +/- 2% 100mV 72% 78 x 67 x 93
DR-45-12 45 Watt 85~264V AC 1ph 120~370V DC 12V DC 3.5A +/- 1% 200mV 77% 78 x 67 x 93
DR-45-15 45 Watt 85~264V AC 1ph 120~370V DC 15V DC 2.8A +/- 1% 240mV 77% 78 x 67 x 93
DR-45-24 45 Watt 85~264V AC 1ph 120~370V DC 24V DC 2.0A +/- 1% 480mV 80% 78 x 67 x 93

A high quality, highly cost effective range of DIN rail mounted switched-mode power supplies from 75W to 960W in the new high
efficiency SDR series. The SDR range is a special narrow profile and units are designed to optimise the space on the DIN rail.
All these types are ex stock and are approved to EN, UL and are CE marked.They have universal inputs and all units are fully
protected against overload, short circuit, over voltage and have an LED ‘power on’ indicator.
Each unit is subjected to a 100% full load burn-in test. All units have a DC output adjuster to increase the rated output voltage.
Safety standards are to EN and UL requirements and CE marking is standard. All units have a full 3 years warranty. They have a
wide ambient temperature range of –25 to + 70 deg C.

High efficiency and slimline construction


Competitive prices
High quality, approved to EN, UL and CE

In 75 Watt,120 Watt, 240 Watt, 480 Watt & 960 Watt ratings
Wide input range
Output voltages of 12V, 24V and 48V DC

EMC standards EN 55022 class B,


and EN 61000-4-2,3,4,5,6,8,11
EN 55024, EN 61000-6-2 and EN 61204-3

Reference Watts Input voltage Output voltage Load & Line Ripple & Efficiency Dimensions
and current regulation noise L x D x H mm

SDR-75-12 75 Watt 88~264V AC 1ph 124~370V DC 12V DC 6.3A +/- 1% 100mV 88.5% 32 x 113.5 x 125
SDR-75-24 75 Watt 88~264V AC 1ph 124~370V DC 24V DC 3.2A +/- 1% 100mV 89% 32 x 113.5 x 125
SDR-75-48 75 Watt 88~264V AC 1ph 124~370V DC 48V DC 1.6A +/- 1% 120mV 90% 32 x 113.5 x 125
SDR-120-12 120 Watt 88~264V AC 1ph 124~370V DC 12V DC 10A +/- 1% 100mV 89% 40 x 113.5 x 125
SDR-120-24 120 Watt 88~264V AC 1ph 124~370V DC 24V DC 5.0A +/- 1% 100mV 91% 40 x 113.5 x 125
SDR-120-48 120 Watt 88~264V AC 1ph 124~370V DC 48V DC 2.5A +/- 1% 120mV 90% 40 x 113.5 x 125
SDR-240-24 240 Watt 88~264V AC 1ph 124~370V DC 24V DC 10A +/- 1% 100mV 94% 63 x 113.5 x 125
SDR-240-48 240 Watt 88~264V AC 1ph 124~370V DC 48V DC 5.0A +/- 1% 120mV 94% 63 x 113.5 x 125
SDR-480-24 480 Watt 90~264V AC 1ph 127~370V DC 24V DC 20A +/- 1% 100mV 94% 85.5 x 128.5 x 125
SDR-480-48 480 Watt 90~264V AC 1ph 127~370V DC 48V DC 10A +/- 1% 120mV 94% 85.5 x 128.5 x 125
SDR-960-24 960 Watt 180~264V AC 1ph 254~370V DC 24V DC 40A +/- 1% 180mV 94% 110 x 150 x 125
SDR-960-48 960 Watt 180~264V AC 1ph 254~370V DC 48V DC 20A +/- 1% 250mV 94% 110 x 150 x 125

Page 32
STOCK RANGE OF WIDE INPUT RANGE
AC TO DC DIN RAIL MOUNTED SWITCHED-MODE POWER SUPPLIES

Wide input range of 180~550V 2 wire (1ph or 2ph).


Competitive prices and ex stock deliveries.
High quality, approved to UL, CUL, TUV and CE.

From 120 Watt to 480 Watt.

Output voltages of 12V, 24V and 48V DC.

EMC standards EN 55011,EN55022 Class B.


EN61000-4-2,3,4,5,6,8,11,EN50204,EN61000-6-2,
EN61204-3 heavy industrial level.

A high quality, highly cost-effective range of wide input range DIN rail mounted switched-mode power supplies from 120W up to
480W.
These units are a special wide input range of 2 wire 180~550V AC. All these types are ex stock. All units are available in a variety of
output voltages, they are approved to EN and UL and are CE marked. They are fully protected against overload, short circuit and
over voltage and they have an LED ‘power on’ indicator and a built in ‘DC OK’ relay contact.
Each unit is subjected to a 100% full load burn-in test. All units have a DC output adjuster to increase the rated output voltage.
Safety standards are to EN and UL requirements and CE marking is standard.

Reference Watts Input voltage Output voltage Load & Line Ripple & Efficiency Dimensions (mm)
and current regulation noise WxDxH

WDR-120-12 120 Watt 180~550V AC 2ph : 254~780V DC 12V DC 10A +/- 1.5% 80mV 88% 40 x 113.5 x 125.2

WDR-120-24 120 Watt 180~550V AC 2ph : 254~780V DC 24V DC 5A +/- 1% 80mV 89% 40 x 113.5 x 125.2

WDR-120-48 120 Watt 180~550V AC 2ph : 254~780V DC 48V DC 2.5A +/- 1% 80mV 89% 40 x 113.5 x 125.2

WDR-240-24 240 Watt 180~550V AC 2ph : 254~780V DC 24V DC 10A +/- 1% 120mV 90% 63 x 113.5 x 125.2

WDR-240-48 240 Watt 180~550V AC 2ph : 254~780V DC 48V DC 5A +/- 1% 120mV 90% 63 x 113.5 x 125.2

WDR-480-24 480 Watt 180~550V AC 2ph : 254~780V DC 24V DC 20A +/- 1% 100mV 94% 85.5 x 128.5 x 125.2

WDR-480-48 480 Watt 180~550V AC 2ph : 254~780V DC 48V DC 10A +/- 1% 120mV 94% 85.5 x 128.5 x 125.2

40A DC UPS MODULE 24V & 20A REDUNDANCY MODULE 21~28V DC

Two additional DIN rail mounted power products for 24V DC


operation.
A redundancy module rated at 21~28V DC 20A with relay
contact signal output and LED indicator for input failure
alarm.
A DC-UPS module rated at 24~29V DC 40A for battery back
up of 24VDC DIN rail mounted power systems

Reference Rating Description

DR-RDN20 21~28V DC 20A Suitable for redundant


operation of 24V system
DR-UPS40 24~29V DC 40A Battery controller
DR-RDN20 for DIN rail UPS system DR-UPS40

Page 33
NEW EDR ECONOMICAL DIN RAIL POWER SUPPLIES FROM 75W TO 150W
AND NEW NDR HIGH SPECIFICATION DIN RAIL POWER SUPPLIES FROM 75W TO 480W

Input range of 90~264V AC 1ph 47~63Hz or 127~370V DC.


Competitive prices and ex stock deliveries.
High quality, approved to UL 508 and TUV EN 60950-1.

EDR series in 75 Watt, 120 Watt and 150 Watt.


NDR series in 75 Watt, 120 Watt, 240 Watt and 480 Watt.

Output voltages of 12V, 24V and 48V DC (see below).

100% full load burn-in test.


2 year warranty (EDR series).
3 year warranty (NDR series).

A new high quality, economical range of wide input voltage, DIN rail mounted, switched mode power supplies from 75W up to
150W.
These units have a special narrow profile to optimise space on the DIN rail. All types are ex stock. They are available in a variety of
output voltages. They are approved to UL 508 (industrial control equipment) with UL/CUL/TUV/CB and CE pending. They are fully
protected against overload, short circuit, over voltage and over temperature and they have an LED ‘power on’ indicator.
Each unit is subjected to a 100% full load burn-in test. All units have a DC output adjuster to increase the rated output voltage to
+15%. EMC standards are to EN 61000-6-2 (EN 50082-2).

Reference Watts Input voltage Output voltage Load & Line Ripple & Efficiency Dimensions (mm)
and current DC regulation noise WxDxH

EDR-75-12 75 Watt 90~264V AC : 127~370V DC 12V 6.3A +/- 2% 100mV 82% 32 x 102 x 125.2
EDR-75-24 75 Watt 90~264V AC : 127~370V DC 24V 3.2A +/- 1% 150mV 84% 32 x 102 x 125.2
EDR-75-48 75 Watt 90~264V AC : 127~370V DC 48V 1.6A +/- 1% 240mV 85% 32 x 102 x 125.2
EDR-120-12 120 Watt 90~264V AC : 127~370V DC 12V 10A +/- 2% 100mV 82% 40 x 113.5 x 125.2
EDR-120-24 120 Watt 90~264V AC : 127~370V DC 24V 5A +/- 1% 100mV 84% 40 x 113.5 x 125.2
EDR-120-48 120 Watt 90~264V AC : 127~370V DC 48V 2.5A +/- 1% 120mV 85% 40 x 113.5 x 125.2
EDR-150-24 150 Watt 90~264V AC : 127~370V DC 24V 6.5A +/- 1% 150mV 87% 40 x 113.5 x 125.2

A new high quality, economical range of wide input voltage, DIN rail mounted, switched mode power supplies from 75W up to 480W.
These units are a special narrow profile to optimise space on the DIN rail. All types are ex stock. They are available in a variety of
output voltages and are approved to UL508 (industrial control equipment) with UL/CUL/TUV/CB and CE pending. They are fully
protected against overload, short circuit , over voltage and over temperature and they have an LED ‘power on’ indicator.
Each unit is subjected to a 100% full load burn-in test. All units have a DC output adjuster to increase the rated output voltage to
+15%. EMC standards are to EN 61000-6-2 (EN 50082-2).
All units have a full 3 years warranty and are designed for a wide ambient temperature range from –20 to +70 deg C.

Reference Watts Input voltage Output voltage Load & Line Ripple & Efficiency Dimensions (mm)
and current DC regulation noise WxDxH

NDR-75-12 75 Watt 90~264V AC : 127~370V DC 12V 6.3A +/- 2% 80mV 85.5% 32 x 102 x 125.2

NDR-75-24 75 Watt 90~264V AC : 127~370V DC 24V 3.2A +/- 1% 120mV 88% 32 x 102 x 125.2

NDR-75-48 75 Watt 90~264V AC : 127~370V DC 48V 1.6A +/- 1% 150mV 89% 32 x 102 x 125.2

NDR-120-12 120 Watt 90~264V AC : 127~370V DC 12V 10A +/- 2% 100mV 85.5% 40 x 113.5 x 125.2

NDR-120-24 120 Watt 90~264V AC : 127~370V DC 24V 5A +/- 1% 120mV 88% 40 x 113.5 x 125.2

NDR-120-48 120 Watt 90~264V AC : 127~370V DC 48V 2.5A +/- 1% 150mV 89% 40 x 113.5 x 125.2

NDR-240-24 240 Watt 90~264V AC : 127~370V DC 24V 10A +/- 1% 150mV 88.5% 63 x 113.5 x 125.2

NDR-240-48 240 Watt 90~264V AC : 127~370V DC 48V 5A +/- 1% 150mV 90% 63 x 113.5 x 125.2

NDR-480-24 480 Watt 90~264V AC : 127~370V DC 24V 20A +/- 1% 150mV 92.5% 85.5 x 128.5 x 125.2

NDR-480-48 480 Watt 90~264V AC : 127~370V DC 48V 10A +/- 1% 150mV 92.5% 85.5 x 128.5 x 125.2

Page 34
TDR 960W HIGH INPUT VOLTAGE DIN RAIL POWER SUPPLIES
AND DRA SERIES OF OUTPUT PROGRAMMABLE DIN RAIL POWER SUPPLIES FROM 40W~60W

TDR series of wide input range 340~550V 3ph 47~63Hz


(or with 2ph input possible).
Compact design with width of only 110mm.
Ex stock delivery.
High efficiency of >94%, approved UL 508: industrial equipment.
960 Watts in 24V or 48V DC output voltage types.

Industrial immunity level EN 61000-6-2 (EN 50082-2).


Current sharing with 4 units up to 3840 Watts in parallel.
100% full load burn-in test.
3 years warranty.

Two high quality, high efficiency DIN rail mounted switched-mode power supplies in 960W rating.
These units have a special wide input range of 3 wire 340~550V AC. Both types are ex stock and are available in 24V and 48V DC.
They are approved to UL 508 and IEC 60950-1 CB approved by SIQ. They are CE marked and they are fully protected against
overload, short circuit, over voltage and over temperature and they have an LED ‘power on’ indicator and a built-in DC OK relay
contact. To give a total power rating of 3.84 kW 4 units can be parallel connected on the output
Each unit is subjected to a 100% full load burn-in test. All units have a DC output adjuster to increase the rated output voltage by up
to 15%. Safety standards are to UL 508 requirements and CE marking is standard.
Both type have a full 3 year warranty.

Reference Watts Input voltage Output voltage Load & Line Ripple & Efficiency Dimensions (mm)
and current regulation noise WxDxH
TDR-960-24 960 Watt 340~550V AC 3ph : 480~780V DC 24V DC 40A +/- 1% 180mV 94% 110 X 150 X 125
TDR-960-48 960 Watt 340~550V AC 3ph : 480~780V DC 48V DC 20A +/- 1% 180mV 94.5% 110 X 150 X 125

DRA series of DIN rail power supplies with adjustable output current
Universal input 90~264V AC 47~63Hz or 127V~370V DC
Protected against short circuit, overload and over voltage
Voltage adjustable with internal potentiometer
Four types in 40 Watt and 60 Watt ratings and 12V DC and 24V DC
Current adjustable through 1~10V DC, PWM signal or resistance
Pass LPS
LED indicator for power on
100% full load burn-in test
3 years warranty

DRA-40 40W and DRA-60 60W AC/DC DIN rail power supplies featuring adjustable output current. This range targets the industrial
inspection equipment market where LED dimming is used. Users are easily able to change the constant current level, or the LED
dimming level, via 1~10V DC, PWM signal or resistance. All types can be mounted on DIN rail TS-35/7.5 or 15 and all units have a
narrow width profile for applications where space on the DIN rail is limited.
The input range is universal between 90V AC and 264V AC with efficiency levels of between 85% to 87%.
The entire series can operate, under free air convection, from –30 deg C to +70 deg C.
For full data sheets including dimming adjustment and circuit wiring please contact our sales department.

Reference Watts Input voltage Output voltage Load & Line Ripple & Efficiency Dimensions (mm)
and current DC regulation noise WxDxH
DRA-40-12 40 Watt 90~264V AC : 127~370V DC 12V 3.34A +/- 1% 120mV 85% 40 x 100 x 90
DRA-40-24 40 Watt 90~264V AC : 127~370V DC 24V 1.70A +/- 1% 150mV 87% 40 x 100 x 90
DRA-60-12 60 Watt 90~264V AC : 127~370V DC 12V 5.0A +/- 1% 120mV 85% 40 x 100 x 90
DRA-60-24 60 Watt 90~264V AC : 127~370V DC 24V 2.5A +/- 1% 150mV 87% 40 x 100 x 90

Reference Constant Current DC Voltage Safety standards MTBF


current region range adjust. range

DRA-40-12 3~12V 0~3.34A 12~15V UL 60950-1 TUV EN 60950-1 approved 439.3K hrs min. MIL-HDBK-217F 25 deg C
DRA-40-24 3~24V 0~1.7A 24~30V UL 60950-1 TUV EN 60950-1 approved 439.3K hrs min. MIL-HDBK-217F 25 deg C
DRA-60-12 3~12V 0~5A 12~15V UL 60950-1 TUV EN 60950-1 approved 436.4K hrs min. MIL-HDBK-217F 25 deg C
DRA-60-24 3~24V 0~2.5A 24~30V UL 60950-1 TUV EN 60950-1 approved 436.4K hrs min. MIL-HDBK-217F 25 deg C

Page 35
RS SERIES OF ENCLOSED MINIATURE POWER SUPPLIES FROM 15W~150W
WITH CHASSIS MOUNTING ENCLOSURE AND DIN RAIL OPTION

RS series of economical switched-mode power supplies.


Ratings from 15 Watts to 150 Watts.
Various output voltages from 3.3V to 48V DC.
Miniature size and high power density.
High efficiency and reliability with long life expectancy.

LED indicator for power on.


100% full load burn in test.
Suitable for critical applications.
3 years warranty.
UL, TUV and EN approvals and CE marked.

A high quality, highly cost-effective range of single phase input chassis mounted switched mode power supplies from 15W up to
150W. All units are available in a variety of output voltages, they are approved to UL, TUV, EN and are CE marked. They are fully
protected against overload, short circuit, over temperature and over voltage and they have an LED ‘power on’ indicator.
Each unit is subjected to a 100% full load burn-in test. All units have a DC output adjuster to increase the rated output voltage
by +/-10%. All units can be fitted with a DIN rail adaptor for ease of mounting to DIN rail.
All units have a full 3 years warranty and are designed for a wide ambient temperature range from –20 to +70 deg C. They have a
withstand surge of 300V AC for 5 seconds.

Reference Watts Input voltage Output voltage Tolerance Ripple & Efficiency Dimensions (mm)
and current DC noise LxWxH

RS-15-3.3 15 Watt 85~264V AC 120~370V DC 3.3V 0~3.0A +/-3% 80mV 72% 62.5 x 51 x 28
RS-15-5 15 Watt 85~264V AC 120~370V DC 5V 0~3.0A +/-2% 80mV 77% 62.5 x 51 x 28
RS-15-12 15 Watt 85~264V AC 120~370V DC 12V 0~1.3A +/-1% 120mV 81% 62.5 x 51 x 28
RS-15-15 15 Watt 85~264V AC 120~370V DC 15V 0~1.0A +/-1% 120mV 81% 62.5 x 51 x 28
RS-15-24 15 Watt 85~264V AC 120~370V DC 24V 0~0.625A +/-1% 200mV 82% 62.5 x 51 x 28
RS-15-48 15 Watt 85~264V AC 120~370V DC 48V 0~0.313A +/-1% 200mV 82% 62.5 x 51 x 28
RS-25-3.3 25 Watt 88~264V AC 125~373V DC 3.3V 0~6.0A +/-3% 80mV 73% 78 x 51 x 28
RS-25-5 25 Watt 88~264V AC 125~373V DC 5V 0~5.0A +/-2% 80mV 78% 78 x 51 x 28
RS-25-12 25 Watt 88~264V AC 125~373V DC 12V 0~2.1A +/-1% 120mV 81% 78 x 51 x 28
RS-25-15 25 Watt 88~264V AC 125~373V DC 15V 0~1.7A +/-1% 120mV 83% 78 x 51 x 28
RS-25-24 25 Watt 88~264V AC 125~373V DC 24V 0~1.1A +/-1% 120mV 86% 78 x 51 x 28
RS-25-48 25 Watt 88~264V AC 125~373V DC 48V 0~0.57A +/-1% 200mV 85% 78 x 51 x 28
RS-35-3.3 35 Watt 88~264V AC 125~373V DC 3.3V 0~7.0A +/-3% 80mV 76% 99 x 82 x 36
RS-35-5 35 Watt 88~264V AC 125~373V DC 5V 0~7.0A +/-2% 80mV 80% 99 x 82 x 36
RS-35-12 35 Watt 88~264V AC 125~373V DC 12V 0~3.0A +/-1% 120mV 84% 99 x 82 x 36
RS-35-15 35 Watt 88~264V AC 125~373V DC 15V 0~2.4A +/-1% 120mV 86% 99 x 82 x 36
RS-35-24 35 Watt 88~264V AC 125~373V DC 24V 0~1.5A +/-1% 120mV 88% 99 x 82 x 36
RS-35-48 35 Watt 88~264V AC 125~373V DC 48V 0~0.8A +/-1% 200mV 88% 99 x 82 x 36
RS-50-3.3 50 Watt 88~264V AC 125~373V DC 3.3V 0~10A +/-3% 80mV 78% 99 x 97 x 36
RS-50-5 50 Watt 88~264V AC 125~373V DC 5V 0~10A +/-2% 80mV 83% 99 x 97 x 36
RS-50-12 50 Watt 88~264V AC 125~373V DC 12V 0~4.2A +/-1% 120mV 84% 99 x 97 x 36
RS-50-15 50 Watt 88~264V AC 125~373V DC 15V 0~3.4A +/-1% 120mV 86% 99 x 97 x 36
RS-50-24 50 Watt 88~264V AC 125~373V DC 24V 0~2.2A +/-1% 120mV 88% 99 x 97 x 36
RS-50-48 50 Watt 88~264V AC 125~373V DC 48V 0~1.1A +/-1% 200mV 89% 99 x 97 x 36
RS-75-3.3 75 Watt 88~264V AC 125~373V DC 3.3V 0~15A +/-3% 80mV 75% 129 x 97 x 38
RS-75-5 75 Watt 88~264V AC 125~373V DC 5V 0~12A +/-2% 80mV 79% 129 x 97 x 38
RS-75-12 75 Watt 88~264V AC 125~373V DC 12V 0~6.0A +/-1% 120mV 84% 129 x 97 x 38
RS-75-15 75 Watt 88~264V AC 125~373V DC 15V 0~5.0A +/-1% 120mV 86% 129 x 97 x 38
RS-75-24 75 Watt 88~264V AC 125~373V DC 24V 0~3.2A +/-1% 120mV 88% 129 x 97 x 38
RS-75-48 75 Watt 88~264V AC 125~373V DC 48V 0~1.6A +/-1% 200mV 89% 129 x 97 x 38
RS-100-3.3 100 Watt 88~264V AC 125~373V DC 3.3V 0~20A +/-3% 80mV 74% 159 x 97 x 38
RS-100-5 100 Watt 88~264V AC 125~373V DC 5V 0~16A +/-2% 80mV 77% 159 x 97 x 38
RS-100-12 100 Watt 88~264V AC 125~373V DC 12V 0~8.5A +/-1% 120mV 81% 159 x 97 x 38
RS-100-15 100 Watt 88~264V AC 125~373V DC 15V 0~7.0A +/-1% 120mV 82% 159 x 97 x 38
RS-100-24 100 Watt 88~264V AC 125~373V DC 24V 0~4.5A +/-1% 120mV 84% 159 x 97 x 38
RS-100-48 100 Watt 88~264V AC 125~373V DC 48V 0~2.3A +/-1% 200mV 84% 159 x 97 x 38
RS-150-3.3 150 Watt 115V / 230V AC by switch 3.3V 0~30A +/-3% 80mV 74% 199 x 98 x 38
RS-150-5 150 Watt 115V / 230V AC by switch 5V 0~26A +/-2% 80mV 78% 199 x 98 x 38
RS-150-12 150 Watt 115V / 230V AC by switch 12V 0~12.5A +/-1% 120mV 83% 199 x 98 x 38
RS-150-15 150 Watt 115V / 230V AC by switch 15V 0~10A +/-1% 120mV 84% 199 x 98 x 38
RS-150-24 150 Watt 115V / 230V AC by switch 24V 0~6.5A +/-1% 120mV 86% 199 x 98 x 38
RS-150-48 150 Watt 115V / 230V AC by switch 48V 0~3.3A +/-1% 200mV 87% 199 x 98 x 38

Page 36
RSP SERIES OF ENCLOSED PFC POWER SUPPLIES
FROM 75 WATT TO 150 WATT

RSP series of economical switched-mode power supplies.


Extra low profile of 30mm.
Ratings from 75 Watts to 150 Watts.
Various output voltages from 3.3V to 48V DC.
Built-in active PFC function.
Cooling by free air convection.
LED indicator for power on.
Built-in constant current limiting.
Remote ON/OFF control.
3 years warranty.
UL, TUV and EN approvals and CE marked.
A high quality, highly cost-effective range of single phase input chassis mounted switched-mode power supplies from 75W up to
150W. All units are available in a variety of output voltages, they are approved to UL, TUV, EN and are CE marked. They are fully
protected against overload, short circuit, over temperature and over voltage and they have an LED ‘power on’ indicator.
All units have a DC output adjuster to decrease or increase the rated output voltage by –5% to +10%.
All units have a full 3 years warranty and are designed for a wide ambient temperature range from –25 to +70 deg C (RSP-75)
and –30 to +70 deg C (RSP-100/150).

Reference Watts Input voltage Output voltage Tolerance Ripple & Efficiency Dimensions
and current DC noise (mm)
LxWxH

RSP-75-3.3 75 Watt 85~264V AC 120~370V DC 3.3V 0~15A +/- 2% 80mV 76% 159 x 97 x 30
RSP-75-5 75 Watt 85~264V AC 120~370V DC 5V 0~15A +/- 2% 80mV 82% 159 x 97 x 30
RSP-75-7.5 75 Watt 85~264V AC 120~370V DC 7.5V 0~10A +/- 2% 80mV 84% 159 x 97 x 30
RSP-75-12 75 Watt 85~264V AC 120~370V DC 12V 0~6.3A +/- 2% 120mV 85% 159 x 97 x 30
RSP-75-13.5 75 Watt 85~264V AC 120~370V DC 13.5V 0~5.6A +/- 2% 120mV 85% 159 x 97 x 30
RSP-75-15 75 Watt 85~264V AC 120~370V DC 15V 0~5A +/- 2% 120mV 86% 159 x 97 x 30
RSP-75-24 75 Watt 85~264V AC 120~370V DC 24V 0~3.2A +/- 1% 120mV 87% 159 x 97 x 30
RSP-75-27 75 Watt 85~264V AC 120~370V DC 27V 0~2.8A +/- 1% 120mV 88% 159 x 97 x 30
RSP-75-48 75 Watt 85~264V AC 120~370V DC 48V 0~1.6A +/- 1% 200mV 89% 159 x 97 x 30
RSP-100-3.3 100 Watt 85~264V AC 120~370V DC 3.3V 0~20A +/- 2% 100mV 83% 179 x 99 x 30
RSP-100-5 100 Watt 85~264V AC 120~370V DC 5V 0~20A +/- 2% 100mV 86% 179 x 99 x 30
RSP-100-7.5 100 Watt 85~264V AC 120~370V DC 7.5V 0~13.5A +/- 2% 100mV 87% 179 x 99 x 30
RSP-100-12 100 Watt 85~264V AC 120~370V DC 12V 0~8.5A +/- 1% 100mV 86% 179 x 99 x 30
RSP-100-13.5 100 Watt 85~264V AC 120~370V DC 13.5V 0~7.5A +/- 1% 100mV 86% 179 x 99 x 30
RSP-100-15 100 Watt 85~264V AC 120~370V DC 15V 0~6.7A +/- 1% 100mV 87% 179 x 99 x 30
RSP-100-24 100 Watt 85~264V AC 120~370V DC 24V 0~4.2A +/- 1% 150mV 87% 179 x 99 x 30
RSP-100-27 100 Watt 85~264V AC 120~370V DC 27V 0~3.8A +/- 1% 150mV 87% 179 x 99 x 30
RSP-100-48 100 Watt 85~264V AC 120~370V DC 48V 0~2.1A +/- 1% 250mV 88% 179 x 99 x 30
RSP-150-3.3 150 Watt 88~264V AC 124~370V DC 3.3V 0~30A +/- 2% 100mV 81% 199 x 99 x 30
RSP-150-5 150 Watt 88~264V AC 124~370V DC 5V 0~30A +/- 2% 100mV 87% 199 x 99 x 30
RSP-150-7.5 150 Watt 88~264V AC 124~370V DC 7.5V 0~20A +/- 2% 100mV 88% 199 x 99 x 30
RSP-150-12 150 Watt 88~264V AC 124~370V DC 12V 0~12.5A +/- 2% 100mV 90% 199 x 99 x 30
RSP-150-13.5 150 Watt 88~264V AC 124~370V DC 13.5V 0~11.2A +/- 2% 100mV 87% 199 x 99 x 30
RSP-150-15 150 Watt 88~264V AC 124~370V DC 15V 0~10A +/- 2% 100mV 88% 199 x 99 x 30
RSP-150-24 150 Watt 88~264V AC 124~370V DC 24V 0~6.3A +/- 1% 150mV 89% 199 x 99 x 30
RSP-150-27 150 Watt 88~264V AC 124~370V DC 27V 0~5.6A +/- 1% 150mV 89% 199 x 99 x 30
RSP-150-48 150 Watt 88~264V AC 124~370V DC 48V 0~3.2A +/- 1% 250mV 90% 199 x 99 x 30

Page 37
RSP SERIES OF ENCLOSED PFC POWER SUPPLIES
FROM 200 WATT TO 320 WATT

RSP series of economical switched-mode power supplies.


Extra low profile of 30mm.
Ratings from 200 Watts to 320 Watts.
Various output voltages from 2.5V to 48V DC.
Built-in active PFC function.
Cooling: 200 Watt by free air convection, 320 Watt by fan.
LED indicator for power on.
Remote ON/OFF control.
3 years warranty.
UL, TUV and EN approvals and CE marked.

A high quality, highly cost-effective range of single phase input chassis mounted switched-mode power supplies from 75W up to
150W. All units are available in a variety of output voltages, they are approved to UL, TUV, EN and are CE marked.They are fully
protected against overload, short circuit, over temperature and over voltage and they have an LED ‘power on’ indicator.
All units have a DC output adjuster to decrease or increase the rated output voltage by –5% to +10% on the 200 Watt units and
+/-10% on the 320 watt units.
All units have a full 3 years warranty and are designed for a wide ambient temperature range from –30 to +70 deg C.

Reference Watts Input voltage Output voltage Tolerance Ripple & Efficiency Dimensions
and current DC noise (mm)
LxWxH

RSP-200-2.5 200 Watt 88~264V AC 124~370V DC 2.5V 0~40A +/- 2% 100mV 79% 215 x 115 x 30
RSP-200-3.3 200 Watt 88~264V AC 124~370V DC 3.3V 0~40A +/- 2% 100mV 81% 215 x 115 x 30
RSP-200-4 200 Watt 88~264V AC 124~370V DC 4V 0~40A +/- 2% 100mV 84% 215 x 115 x 30
RSP-200-5 200 Watt 88~264V AC 124~370V DC 5V 0~40A +/- 2% 100mV 85% 215 x 115 x 30
RSP-200-7.5 200 Watt 88~264V AC 124~370V DC 7.5V 0~26.7A +/- 2% 150mV 89% 215 x 115 x 30
RSP-200-12 200 Watt 88~264V AC 124~370V DC 12V 0~16.7A +/- 1% 150mV 89% 215 x 115 x 30
RSP-200-13.5 200 Watt 88~264V AC 124~370V DC 13.5V 0~14.9A +/- 1% 150mV 89% 215 x 115 x 30
RSP-200-15 200 Watt 88~264V AC 124~370V DC 15V 0~13.4A +/- 1% 150mV 89% 215 x 115 x 30
RSP-200-24 200 Watt 88~264V AC 124~370V DC 24V 0~8.4A +/- 1% 150mV 89% 215 x 115 x 30
RSP-200-27 200 Watt 88~264V AC 124~370V DC 27V 0~7.5A +/- 1% 200mV 89% 215 x 115 x 30
RSP-200-36 200 Watt 88~264V AC 124~370V DC 36V 0~5.56A +/- 1% 220mV 90% 215 x 115 x 30
RSP-200-48 200 Watt 88~264V AC 124~370V DC 48V 0~4.2A +/- 1% 240mV 90% 215 x 115 x 30
RSP-320-2.5 320 Watt 88~264V AC 124~370V DC 2.5V 0~60A +/- 2% 100mV 75% 215 x 115 x 30
RSP-320-3.3 320 Watt 88~264V AC 124~370V DC 3.3V 0~60A +/- 2% 100mV 79% 215 x 115 x 30
RSP-320-4 320 Watt 88~264V AC 124~370V DC 4V 0~60A +/- 2% 100mV 81% 215 x 115 x 30
RSP-320-5 320 Watt 88~264V AC 124~370V DC 5V 0~60A +/- 2% 150mV 83% 215 x 115 x 30
RSP-320-5CC 320 Watt 88~264V AC 124~370V DC 5V 0~60A +/- 2% 150mV 83% 215 x 115 x 30
RSP-320-7.5 320 Watt 88~264V AC 124~370V DC 7.5V 0~40A +/- 2% 150mV 88% 215 x 115 x 30
RSP-320-12 320 Watt 88~264V AC 124~370V DC 12V 0~26.7A +/- 1% 150mV 88% 215 x 115 x 30
RSP-320-13.5 320 Watt 88~264V AC 124~370V DC 13.5V 0~23.8A +/- 1% 150mV 88% 215 x 115 x 30
RSP-320-15 320 Watt 88~264V AC 124~370V DC 15V 0~21.4A +/- 1% 150mV 88% 215 x 115 x 30
RSP-320-24 320 Watt 88~264V AC 124~370V DC 24V 0~13.4A +/- 1% 150mV 89% 215 x 115 x 30
RSP-320-27 320 Watt 88~264V AC 124~370V DC 27V 0~11.9A +/- 1% 200mV 89% 215 x 115 x 30
RSP-320-36 320 Watt 88~264V AC 124~370V DC 36V 0~8.9A +/- 1% 220mV 89% 215 x 115 x 30
RSP-320-48 320 Watt 88~264V AC 124~370V DC 48V 0~6.7A +/- 1% 240mV 90% 215 x 115 x 30

*RSP-320-5CC with conformal coating is suitable for LED moving sign applications, MOQ required.

Page 38
RSP SERIES OF ENCLOSED PFC POWER SUPPLIES
FROM 500 WATT TO 1000 WATT AND PSP 600 WATT

RSP & PSP series of switched-mode power supplies.


RSP-500, RSP-750 and RSP-1000 all low profile.
Ratings 500~1000 Watts (RSP) & 600 Watts (PSP).
Various output voltages from 3.3V to 48V DC.
Built-in active PFC function.
Cooling by fan, forced air.
LED indicator for power on.
Remote ON/OFF control.
3-5 years warranty dependant on model.
UL, TUV and EN approvals and CE marked.

A high quality, highly cost-effective range of single phase input chassis mounted switched-mode power supplies from 500W up to
1000W. All units are available in a variety of output voltages, they are approved to UL, TUV, EN and are CE marked.They are fully
protected against overload, short circuit, over temperature and over voltage and they have an LED ‘power on’ indicator.
All units have a DC output adjuster to decrease or increase the rated output voltage by +/-10%.
Up to 750 Watts all units have a full 3 years warranty and the 1000 Watt units have 5 years warranty. They are designed for a wide
ambient temperature range RSP 500 and RSP 750 from –30 to +70 deg C, PSP 600 and RSP 1000 from –20 to +60 deg C.

Reference Watts Input voltage Output voltage Tolerance Ripple & Efficiency Dimensions (mm)
and current DC noise LxWxH

RSP-500-3.3 500 Watt 85~264V AC 120~370V DC 3.3V 0~90A +/-2% 120mV 81% 230 x 127 x 40.5
RSP-500-4 500 Watt 85~264V AC 120~370V DC 4V 0~90A +/-2% 120mV 83% 230 x 127 x 40.5

RSP-500-5 500 Watt 85~264V AC 120~370V DC 5V 0~90A +/-2% 150mV 83% 230 x 127 x 40.5

RSP-500-12 500 Watt 85~264V AC 120~370V DC 12V 0~41.7A +/-1% 150mV 89% 230 x 127 x 40.5

RSP-500-15 500 Watt 85~264V AC 120~370V DC 15V 0~33.4A +/-1% 150mV 88% 230 x 127 x 40.5

RSP-500-24 500 Watt 85~264V AC 124~370V DC 24V 0~21A +/-1% 150mV 89% 230 x 127 x 40.5

RSP-500-27 500 Watt 85~264V AC 124~370V DC 27V 0~18.6A +/-1% 200mV 89% 230 x 127 x 40.5

RSP-500-48 500 Watt 85~264V AC 124~370V DC 48V 0~105A +/-1% 240mV 90% 230 x 127 x 40.5

PSP-600-5 600 Watt 88~264V AC 124~370V DC 5V 0~80A +/-2% 180mV 79% 170 x 120 x 93

PSP-600-12 600 Watt 88~264V AC 124~370V DC 12V 0~50A +/-1% 240mV 84% 170 x 120 x 93

PSP-600-13.5 600 Watt 88~264V AC 124~370V DC 13.5V 0~44.5A +/-1% 240mV 85% 170 x 120 x 93

PSP-600-15 600 Watt 88~264V AC 124~370V DC 15V 0~40A +/-1% 240mV 85% 170 x 120 x 93

PSP-600-24 600 Watt 88~264V AC 124~370V DC 24V 0~25A +/-1% 240mV 86% 170 x 120 x 93

PSP-600-27 600 Watt 88~264V AC 124~370V DC 27V 0~22.2A +/-1% 240mV 86% 170 x 120 x 93

PSP-600-48 600 Watt 88~264V AC 124~370V DC 48V 0~12.5A +/-1% 300mV 87% 170 x 120 x 93

RSP-750-5 750 Watt 90~264V AC 127~370V DC 5V 0~100A +/-2% 150mV 82% 250 x 127 x 41

RSP-750-12 750 Watt 90~264V AC 127~370V DC 12V 0~62.5A +/-1% 150mV 87% 250 x 127 x 41

RSP-750-15 750 Watt 90~264V AC 127~370V DC 15V 0~50A +/-1% 150mV 89% 250 x 127 x 41

RSP-750-24 750 Watt 90~264V AC 127~370V DC 24V 0~31.3A +/-1% 150mV 90% 250 x 127 x 41

RSP-750-27 750 Watt 90~264V AC 127~370V DC 27V 0~27.8A +/-1% 150mV 90% 250 x 127 x 41

RSP-750-48 750 Watt 90~264V AC 127~370V DC 48V 0~15.7A +/-1% 150mV 92% 250 x 127 x 41

RSP-1000-12 1000 Watt 90~264V AC 127~370V DC 12V 0~60A +/-1% 150mV 83% 295 x 127 x 41

RSP-1000-15 1000 Watt 90~264V AC 127~370V DC 15V 0~50A +/-1% 150mV 85% 295 x 127 x 41

RSP-1000-24 1000 Watt 90~264V AC 127~370V DC 24V 0~40A +/-1% 150mV 88% 295 x 127 x 41

RSP-1000-27 1000 Watt 90~264V AC 127~370V DC 27V 0~37A +/-1% 150mV 88% 295 x 127 x 41

RSP-1000-48 1000 Watt 90~264V AC 127~370V DC 48V 0~21A +/-1% 150mV 90% 295 x 127 x 41

Page 39
RSP SERIES OF ENCLOSED PFC POWER SUPPLIES FROM 1500 WATT TO 3000 WATT
AND RST SERIES 5000 WATT

RSP & RST series of switched-mode power supplies.


RSP with 1ph input and RST with 3ph input (+N).
Ratings 1500~3000 Watts (RSP) & 5000 Watts (RST).
RST 5000 types with 3ph input.
Various output voltages from 5V to 48V DC.
Built-in active PFC function.
Cooling by fan, forced air.
LED indicator for power on.
Remote ON/OFF control.
3 years warranty.
UL, TUV and EN approvals and CE marked.

A high quality, highly cost-effective range of single phase input chassis mounted switched-mode power supplies from 1500W up to
5000W. All units are available in a variety of output voltages, they are approved to UL, TUV, EN and are CE marked. They are fully
protected against overload, short circuit, over temperature and over voltage and they have an alarm signal output.
All units have a DC output adjuster to decrease or increase the rated output voltage by –30% to +10% (RSP 1500) and +/-10% (RSP
1000, RSP 2000, RSP 2400 and RSP 3000) with RST –2% to +20%.
All units have a full 5 years warranty and they are designed for a wide ambient temperature range (details available on request).

Reference Watts Input voltage Output voltage Tolerance Ripple & Efficiency Dimensions (mm)
and current DC noise LxWxH

RSP-1500-5 1500 Watt 90~264V AC 127~370V DC 5V 0~240A +/-2% 150mV 80% 278 x 127 x 83.5

RSP-1500-12 1500 Watt 90~264V AC 127~370V DC 12V 0~125A +/-1% 150mV 87% 278 x 127 x 83.5

RSP-1500-15 1500 Watt 90~264V AC 127~370V DC 15V 0~100A +/-1% 150mV 87% 278 x 127 x 83.5

RSP-1500-24 1500 Watt 90~264V AC 127~370V DC 24V 0~63A +/-1% 150mV 90% 278 x 127 x 83.5

RSP-1500-27 1500 Watt 90~264V AC 127~370V DC 27V 0~56A +/-1% 150mV 90% 278 x 127 x 83.5

RSP-1500-48 1500 Watt 90~264V AC 127~370V DC 48V 0~32A +/-1% 200mV 91% 278 x 127 x 83.5

RSP-2000-12 2000 Watt 90~264V AC 127~370V DC 12V 0~100A +/-2% 150mV 87% 295 x 127 x 41

RSP-2000-24 2000 Watt 90~264V AC 127~370V DC 24V 0~80A +/-1% 200mV 90% 295 x 127 x 41

RSP-2000-48 2000 Watt 90~264V AC 127~370V DC 48V 0~42A +/-1% 300mV 92% 295 x 127 x 41

RSP-2400-12 2400 Watt 180~264V AC 254~270V DC 12V 0~166.7A +/-1% 150mV 87% 278 x 178 x 63.5

RSP-2400-24 2400 Watt 180~264V AC 254~270V DC 24V 0~100A +/-1% 150mV 90% 278 x 178 x 63.5

RSP-2400-48 2400 Watt 180~264V AC 254~270V DC 48V 0~50A +/-1% 200mV 91% 278 x 178 x 63.5

RSP-3000-12 3000 Watt 180~264V AC 254~270V DC 12V 0~200A +/-1% 150mV 86% 278 x 178 x 63.5

RSP-3000-24 3000 Watt 180~264V AC 254~270V DC 24V 0~125A +/-1% 150mV 89% 278 x 178 x 63.5

RSP-3000-48 3000 Watt 180~264V AC 254~270V DC 48V 0~62.5A +/-2% 200mV 90% 278 x 178 x 63.5

RST-5000-24 5000 Watt 196~205V AC 3ph 3 wire Delta 24V 0~200A +/-1% 150mV 89% 480 x 211 x 83.5
340~530V AC 3ph 4 wire Star

RST-5000-48 5000 Watt 196~205V AC 3ph 3 wire Delta 48V 0~105A +/-1% 200mV 91% 480 x 211 x 83.5
340~530V AC 3ph 4 wire Star

Page 40
HLG SERIES OF POWER SUPPLIES FOR HARSH ENVIRONMENTS
FROM 40 WATT TO 60 WATT

Universal AC input up to 305V AC full range.


Built in PFC function.
Efficiency up to 90.5%.
IP65~IP67 rated for indoor and outdoor use.
Class 2 with 3 types:
A type: IP65 with output voltage and current adjustable.
B type: IP67 with 3-in-one dimming function.
(1~10V DC, PWM signal or resistance dimming).
Blank type: IP67 rated with input and output cables.
5 year warranty.

A comprehensive range of harsh environment power supplies with input ranges of 90~305V AC and 127~431V DC. These units
have a single output voltage and are short circuit, over current, over voltage and over temperature protected. They are coole d by
free air convection and are suitable for dry, damp and wet locations. They are suitable for LED lighting and street lighting
applications as well as standard PSU use. They meet the 4kV surge immunity level to IEC61000-4-5.
Safety standards are UL 8750, TUV EN 61347-1, EN 61347-2-13, PSE J61347-1 and PSE J61347-2-13 approved.
Full data sheets available on request.

Reference Watts Output voltage Output adjuster Tolerance Ripple & Efficiency Dimensions (mm)
and current DC noise LxWxH

HLG-40H-12(A) 40 Watt 12V 0~3.33A +/-10% A type +/- 2.5% 150mV 86.5% 171 x 61.5 x 36.8

HLG-40H-15(A) 40 Watt 15V 0~2.67A +/-10% A type +/- 2.0% 150mV 86.5% 171 x 61.5 x 36.8

HLG-40H-20(A) 40 Watt 20V 0~2.00A +/-10% A type +/- 1.0% 150mV 88.0% 171 x 61.5 x 36.8

HLG-40H-24(A) 40 Watt 24V 0~1.67A +/-10% A type +/- 1.0% 200mV 88.0% 171 x 61.5 x 36.8

HLG-40H-30(A) 40 Watt 30V 0~1.34A +/-10% A type +/- 1.0% 200mV 88.5% 171 x 61.5 x 36.8

HLG-40H-36(A) 40 Watt 36V 0~1.12A +/-10% A type +/- 1.0% 200mV 88.5% 171 x 61.5 x 36.8

HLG-40H-42(A) 40 Watt 42V 0~0.96A +/-10% A type +/- 1.0% 200mV 88.5% 171 x 61.5 x 36.8

HLG-40H-48(A) 40 Watt 48V 0~0.84A +/-10% A type +/- 1.0% 300mV 89.5% 171 x 61.5 x 36.8

HLG-40H-54(A) 40 Watt 54V 0~0.75A +/-10% A type +/- 1.0% 300mV 89.5% 171 x 61.5 x 36.8

HLG-60H-15(A) 60 Watt 15V 0~4.00A +/-10% A type +/- 2.0% 150mV 87.5% 171 x 61.5 x 36.8

HLG-60H-20(A) 60 Watt 20V 0~3.00A +/-10% A type +/- 1.0% 150mV 89.0% 171 x 61.5 x 36.8

HLG-60H-24(A) 60 Watt 24V 0~2.50A +/-10% A type +/- 1.0% 150mV 89.5% 171 x 61.5 x 36.8

HLG-60H-30(A) 60 Watt 30V 0~2.00A +/-10% A type +/- 1.0% 200mV 90.0% 171 x 61.5 x 36.8

HLG-60H-36(A) 60 Watt 36V 0~1.70A +/-10% A type +/- 1.0% 200mV 90.0% 171 x 61.5 x 36.8

HLG-60H-42(A) 60 Watt 42V 0~1.45A +/-10% A type +/- 1.0% 300mV 90.0% 171 x 61.5 x 36.8

HLG-60H-48(A) 60 Watt 48V 0~1.30A +/-10% A type +/- 1.0% 300mV 90.5% 171 x 61.5 x 36.8

HLG-60H-54(A) 60 Watt 54V 0~1.15A +/-10% A type +/- 1.0% 300mV 90.5% 171 x 61.5 x 36.8

Page 41
HLG SERIES OF POWER SUPPLIES FOR HARSH ENVIRONMENTS
FROM 80 WATT TO 120 WATT

Universal AC input up to 305V AC full range.


Built in PFC function.
Efficiency up to 93.5%.
IP65~IP67 rated for indoor and outdoor use.
Class 2 with 5 types:
A type: IP65 with output voltage and current adjustable.
B type: IP67 with 3 in one dimming function.
(1~10V DC, PWM signal or resistance dimming).
Blank type: IP67 rated with input and output cables.
D type and BL type options details on request.
5 year warranty.

A comprehensive range of harsh environment power supplies with input ranges of 90~305V AC and 127~431V DC. These units
have a single output voltage and are short circuit, over current, over voltage and over temperature protected. They are cooled by
free air convection and are suitable for dry, damp and wet locations. They are suitable for LED lighting and street lighting
applications as well as standard PSU use. They meet the 4kV surge immunity level to IEC61000-4-5.
Safety standards are UL 8750, TUV EN 61347-1, EN 61347-2-13, PSE J61347-1 and PSE J61347-2-13 approved.
Full data sheets available on request.

Reference Watts Output voltage Output adjuster Tolerance Ripple & Efficiency Dimensions (mm)
and current DC noise LxWxH

HLG-80H-12(A) 80 Watt 12V 0~5.0A +/-10% A type +/- 2.5% 150mV 88.0% 195.6 x 61.5 x 38.8

HLG-80H-15(A) 80 Watt 15V 0~5.0A +/-10% A type +/- 2.0% 150mV 89.0% 195.6 x 61.5 x 38.8

HLG-80H-20(A) 80 Watt 20V 0~4.0A +/-10% A type +/- 1.0% 150mV 90.0% 195.6 x 61.5 x 38.8

HLG-80H-24(A) 80 Watt 24V 0~3.4A +/-10% A type +/- 1.0% 150mV 90.5% 195.6 x 61.5 x 38.8

HLG-80H-30(A) 80 Watt 30V 0~2.7A +/-10% A type +/- 1.0% 200mV 91.0% 195.6 x 61.5 x 38.8
HLG-80H-36(A) 80 Watt 36V 0~2.3A +/-10% A type +/- 1.0% 200mV 91.0% 195.6 x 61.5 x 38.8

HLG-80H-42(A) 80 Watt 42V 0~1.95A +/-10% A type +/- 1.0% 200mV 91.0% 195.6 x 61.5 x 38.8

HLG-80H-48(A) 80 Watt 48V 0~1.7A +/-10% A type +/- 1.0% 200mV 91.0% 195.6 x 61.5 x 38.8

HLG-80H-54(A) 80 Watt 54V 0~1.5A +/-10% A type +/- 1.0% 200mV 91.0% 195.6 x 61.5 x 38.8

HLG-100H-20(A) 100 Watt 20V 0~4.8A +/-10% A type +/- 1.0% 150mV 93.0% 220 x 68 x 38.8

HLG-100H-24(A) 100 Watt 24V 0~4.0A +/-10% A type +/- 1.0% 150mV 93.0% 220 x 68 x 38.8

HLG-100H-30(A) 100 Watt 30V 0~3.2A +/-10% A type +/- 1.0% 200mV 93.0% 220 x 68 x 38.8

HLG-100H-36(A) 100 Watt 36V 0~2.65A +/-10% A type +/- 1.0% 200mV 93.0% 220 x 68 x 38.8

HLG-100H-42(A) 100 Watt 42V 0~2.28A +/-10% A type +/- 1.0% 200mV 93.0% 220 x 68 x 38.8

HLG-100H-48(A) 100 Watt 48V 0~2.0A +/-10% A type +/- 1.0% 200mV 93.0% 220 x 68 x 38.8

HLG-100H-54(A) 100 Watt 54V 0~1.77A +/-10% A type +/- 1.0% 200mV 93.0% 220 x 68 x 38.8

HLG-120H-12(A) 120 Watt 12V 0~10A +/-10% A type +/- 2.5% 150mV 92.0% 220 x 68 x 38.8

HLG-120H-15(A) 120 Watt 15V 0~8.0A +/-10% A type +/- 2.0% 150mV 92.0% 220 x 68 x 38.8

HLG-120H-20(A) 120 Watt 20V 0~6.0A +/-10% A type +/- 1.0% 150mV 93.0% 220 x 68 x 38.8

HLG-120H-24(A) 120 Watt 24V 0~5.0A +/-10% A type +/- 1.0% 150mV 93.0% 220 x 68 x 38.8

HLG-120H-30(A) 120 Watt 30V 0~4.0A +/-10% A type +/- 1.0% 200mV 93.0% 220 x 68 x 38.8

HLG-120H-36(A) 120 Watt 36V 0~3.4A +/-10% A type +/- 1.0% 200mV 93.0% 220 x 68 x 38.8

HLG-120H-42(A) 120 Watt 42V 0~2.9A +/-10% A type +/- 1.0% 200mV 93.0% 220 x 68 x 38.8

HLG-120H-48(A) 120 Watt 48V 0~2.5A +/-10% A type +/- 1.0% 200mV 93.5% 220 x 68 x 38.8

HLG-120H-54(A) 120 Watt 54V 0~2.3A +/-10% A type +/- 1.0% 200mV 93.5% 220 x 68 x 38.8

Page 42
HLG SERIES OF POWER SUPPLIES FOR HARSH ENVIRONMENTS
FROM 150 WATT TO 240 WATT

Universal AC input up to 305V AC full range.


Built in PFC function.
Efficiency up to 94%.
IP65~IP67 rated for indoor and outdoor use.
Class 2 with 5 types:
A type: IP65 with output voltage and current adjustable.
B type: IP67 with 3 in one dimming function.
(1~10V DC, PWM signal or resistance dimming).
Blank type: IP67 rated with input and output cables.
D type option and BL type options details on request.
5 year warranty.

A comprehensive range of harsh environment power supplies with input ranges of 90~305V AC and 127~431V DC. These units
have a single output voltage and are short circuit, over current, over voltage and over temperature protected. They are cooled by
free air convection and are suitable for dry, damp and wet locations. They are suitable for LED lighting and street lighting
applications as well as standard PSU use. They meet the 4kV surge immunity level to IEC61000-4-5.
Safety standards are UL 8750, TUV EN 61347-1, EN 61347-2-13, PSE J61347-1 and PSE J61347-2-13 approved.
Full data sheets available on request.

Reference Watts Output voltage Output adjuster Tolerance Ripple & Efficiency Dimensions (mm)
and current DC noise LxWxH

HLG-150H-12(A) 150 Watts 12V 0~12.5A +/-10% A type +/- 2.5% 150mV 91.5% 228 x 68 x 38.8
HLG-150H-15(A) 150 Watts 15V 0~10.0A +/-10% A type +/- 2.0% 150mV 92.0% 228 x 68 x 38.8

HLG-150H-20(A) 150 Watts 20V 0~7.50A +/-10% A type +/- 1.0% 150mV 93.0% 228 x 68 x 38.8

HLG-150H-24(A) 150 Watts 24V 0~6.30A +/-10% A type +/- 1.0% 150mV 93.0% 228 x 68 x 38.8

HLG-150H-30(A) 150 Watts 30V 0~5.00A +/-10% A type +/- 1.0% 200mV 93.5% 228 x 68 x 38.8
HLG-150H-36(A) 150 Watts 36V 0~4.20A +/-10% A type +/- 1.0% 200mV 93.5% 228 x 68 x 38.8

HLG-150H-42(A) 150 Watts 42V 0~3.60A +/-10% A type +/- 1.0% 200mV 94.0% 228 x 68 x 38.8

HLG-150H-48(A) 150 Watts 48V 0~3.20A +/-10% A type +/- 1.0% 200mV 94.0% 228 x 68 x 38.8

HLG-150H-54(A) 150 Watts 54V 0~2.80A +/-10% A type +/- 1.0% 200mV 94.0% 228 x 68 x 38.8

HLG-185H-12(A) 185 Watts 12V 0~13.0A +/-10% A type +/- 2.5% 150mV 91.5% 228 x 68 x 38.8

HLG-185H-15(A) 185 Watts 15V 0~11.5A +/-10% A type +/- 2.0% 150mV 92.0% 228 x 68 x 38.8

HLG-185H-20(A) 185 Watts 20V 0~9.30A +/-10% A type +/- 1.0% 150mV 93.0% 228 x 68 x 38.8

HLG-185H-24(A) 185 Watts 24V 0~7.80A +/-10% A type +/- 1.0% 150mV 93.5% 228 x 68 x 38.8

HLG-185H-30(A) 185 Watts 30V 0~6.20A +/-10% A type +/- 1.0% 200mV 93.5% 228 x 68 x 38.8

HLG-185H-36(A) 185 Watts 36V 0~5.20A +/-10% A type +/- 1.0% 200mV 93.5% 228 x 68 x 38.8

HLG-185H-42(A) 185 Watts 42V 0~4.40A +/-10% A type +/- 1.0% 200mV 94.0% 228 x 68 x 38.8

HLG-185H-48(A) 185 Watts 48V 0~3.90A +/-10% A type +/- 1.0% 200mV 94.0% 228 x 68 x 38.8

HLG-185H-54(A) 185 Watts 54V 0~3.45A +/-10% A type +/- 1.0% 200mV 94.0% 228 x 68 x 38.8

HLG-240H-12(A) 240 Watts 12V 0~16.0A +/-10% A type +/- 2.5% 150mV 90.0% 244 x 68 x 38.8

HLG-240H-15(A) 240 Watts 15V 0~15.0A +/-10% A type +/- 2.0% 150mV 90.0% 244 x 68 x 38.8

HLG-240H-20(A) 240 Watts 20V 0~12.0A +/-10% A type +/- 1.0% 150mV 91.5% 244 x 68 x 38.8

HLG-240H-24(A) 240 Watts 24V 0~10.0A +/-10% A type +/- 1.0% 150mV 92.5% 244 x 68 x 38.8

HLG-240H-30(A) 240 Watts 30V 0~8.00A +/-10% A type +/- 1.0% 200mV 92.5% 244 x 68 x 38.8

HLG-240H-36(A) 240 Watts 36V 0~6.70A +/-10% A type +/- 1.0% 250mV 92.5% 244 x 68 x 38.8

HLG-240H-42(A) 240 Watts 42V 0~5.72A +/-10% A type +/- 1.0% 250mV 92.5% 244 x 68 x 38.8

HLG-240H-48(A) 240 Watts 48V 0~5.00A +/-10% A type +/- 1.0% 250mV 93.0% 244 x 68 x 38.8

HLG-240H-54(A) 240 Watts 54V 0~4.45A +/-10% A type +/- 1.0% 250mV 93.5% 244 x 68 x 38.8

Page 43
HLG SERIES OF POWER SUPPLIES FOR HARSH ENVIRONMENTS
FROM 320 WATT TO 600 WATT

Universal AC input up to 305V AC full range.


Built in PFC function.
Efficiency up to 96%.
IP65~IP67 rated for indoor and outdoor use.
Class 2 with 4 types:
A type: IP65 with output voltage and current adjustable.
B type: IP67 with 3 in one dimming function.
(1~10V DC, PWM signal or resistance dimming).
Blank type: IP67 rated with input and output cables.
D type option details on request.
5 year warranty.

A comprehensive range of harsh environment power supplies with input ranges of 90~305V AC and 127~431V DC. These units have
a single output voltage and are short circuit, over current, over voltage and over temperature protected. They are cooled by free air
convection and are suitable for dry, damp and wet locations. They are suitable for LED lighting and street lighting
applications as well as standard PSU use. They meet the 4kV surge immunity level to IEC61000-4-5.
Safety standards are UL 8750, TUV EN 61347-1, EN 61347-2-13, PSE J61347-1 and PSE J61347-2-13 approved for 320W
and UL 60950-1, UL 8750, ENEC EN 61347-1/2-13 and EN 62384 for 600W. Full data sheets available on request.

Reference Watts Output voltage Output adjuster Tolerance Ripple & Efficiency Dimensions (mm)
and current DC noise LxWxH

HLG-320H-12(A) 320 Watts 12V 0~22.0A -15%~+13.3% A type +/-3.0% 150mV 91.0% 252 x 90 x 43.8

HLG-320H-15(A) 320 Watts 15V 0~19.0A -15%~+13.3% A type +/-2.0% 150mV 92.5% 252 x 90 x 43.8

HLG-320H-20(A) 320 Watts 20V 0~15.0A -15%~+13.3% A type +/-1.5% 150mV 93.5% 252 x 90 x 43.8

HLG-320H-24(A) 320 Watts 24V 0~13.34A -15%~+13.3% A type +/-1.0% 150mV 94.0% 252 x 90 x 43.8

HLG-320H-30(A) 320 Watts 30V 0~10.7A -15%~+13.3% A type +/-1.0% 200mV 94.0% 252 x 90 x 43.8

HLG-320H-36(A) 320 Watts 36V 0~8.90A -15%~+13.3% A type +/-1.0% 250mV 94.5% 252 x 90 x 43.8

HLG-320H-42(A) 320 Watts 42V 0~7.65A -15%~+13.3% A type +/-1.0% 250mV 95.0% 252 x 90 x 43.8

HLG-320H-48(A) 320 Watts 48V 0~6.70A -15%~+13.3% A type +/-1.0% 250mV 95.0% 252 x 90 x 43.8

HLG-320H-54(A) 320 Watts 54V 0~5.95A -15%~+13.3% A type +/-1.0% 350mV 95.0% 252 x 90 x 43.8

HLG-600H-12(A) 600 Watts 12V 0~40.0A -15%~+5% A type +/-3.0% 150mV 92.0% 280 x 144 x 48.5

HLG-600H-15(A) 600 Watts 15V 0~36.0A -15%~+5% A type +/-2.0% 150mV 93.5% 280 x 144 x 48.5

HLG-600H-20(A) 600 Watts 20V 0~28.0A -15%~+5% A type +/-1.5% 150mV 94.5% 280 x 144 x 48.5

HLG-600H-24(A) 600 Watts 24V 0~25.0A -15%~+5% A type +/-1.0% 150mV 95.0% 280 x 144 x 48.5

HLG-600H-30(A) 600 Watts 30V 0~20.0A -15%~+5% A type +/-1.0% 200mV 95.0% 280 x 144 x 48.5

HLG-600H-36(A) 600 Watts 36V 0~16.7A -15%~+5% A type +/-1.0% 250mV 95.5% 280 x 144 x 48.5

HLG-600H-42(A) 600 Watts 42V 0~14.3A -15%~+5% A type +/-1.0% 250mV 96.0% 280 x 144 x 48.5

HLG-600H-48(A) 600 Watts 48V 0~12.5A -15%~+5% A type +/-1.0% 250mV 96.0% 280 x 144 x 48.5

HLG-600H-54(A) 600 Watts 54V 0~11.2A -15%~+5% A type +/-1.0% 350mV 96.0% 280 x 144 x 48.5

Page 44
DC/DC CONVERTERS FROM 15W TO 1000W
WITH SINGLE 24V DC OUTPUT

Single 24V DC output.


Universal DC input: 2 to1 (and 4 to 1) wide input range.
9.2~18V DC,19~36V DC, 36~72V DC or 72~144V DC.

Short circuit, overload and over voltage protected.


100% burn-in test and full 1 year warranty.

Built in EMI filter, low ripple noise.

Standards: LVD (see specification).


EMC : EN 55022 Class B,EN 6100-42, 3, 4, 6, 8, ENV 50204.

A comprehensive range of DC/DC converters with input ranges of 9.2~18V DC, 19~36V DC, 36~72V DC or 72~144V with the 1000W
units having an input of 19~72V DC and 72~144V DC. These units have a single output voltage of 24V DC and are short
circuit, overload and over voltage protected. The 200W type and larger have additional over temperature protection.
Units from 15W to 200W are cooled by free air convection with larger units being forced air cooled by a built in DC fan.

Reference Watts Input Output voltage Input/output Ripple & Efficiency Dimensions (mm) & weight
voltage DC and current DC isolation noise W x D x H: (kg)
SD-15A-24 15 Watt 9.2V~18V 24V 0.625A 2000V DC 150mV 70% 78 x 51 x 28mm: 0.18kg

SD-15B-24 15 Watt 19~36V 24V 0.625A 1500V DC 150mV 77% 78 x 51 x 28mm: 0.18kg

SD-15C-24 15 Watt 36~72V 24V 0.625A 1500V DC 150mV 78% 78 x 51 x 28mm: 0.18kg

SD-25A-24 25 Watt 9.2V~18V 24V 1.10A 1500V DC 150mV 75% 99 x 97 x 36mm: 0.38kg

SD-25B-24 25 Watt 19~36V 24V 1.10A 1500V DC 150mV 78% 99 x 97 x 36mm: 0.38kg
SD-25C-24 25 Watt 36~72V 24V 1.10A 1500V DC 150mV 81% 99 x 97 x 36mm: 0.38kg

SD-50A-24 50 Watt 9.2V~18V 24V 2.10A 1500V DC 150mV 74% 159 x 97 x 38mm: 0.53kg

SD-50B-24 50 Watt 19~36V 24V 2.10A 1500V DC 150mV 80% 159 x 97 x 38mm: 0.53kg

SD-50C-24 50 Watt 36~72V 24V 2.10A 1500V DC 150mV 83% 159 x 97 x 38mm: 0.53kg

SD-100B-24 100 Watt 19~36V 24V 4.20A 1500V DC 150mV 78% 199 x 98 x 38mm: 0.65kg

SD-100C-24 100 Watt 36~72V 24V 4.20A 1500V DC 150mV 81% 199 x 98 x 38mm: 0.65kg

SD-100D-24 100 Watt 72~144V 24V 4.20A 1500V DC 150mV 83% 199 x 98 x 38mm: 0.65kg

SD-150B-24 150 Watt 19~36V 24V 6.30A 1500V DC 150mV 77% 199 x 110 x 50mm: 0.86kg

SD-150C-24 150 Watt 36~72V 24V 6.30A 1500V DC 150mV 80% 199 x 110 x 50mm: 0.86kg

SD-150D-24 150 Watt 72~144V 24V 6.30A 1500V DC 150mV 82% 199 x 110 x 50mm: 0.86kg

SD-200B-24 200 Watt 19~36V 24V 8.40A 1500V DC 150mV 85% 215 x 115 x 50mm: 1.1kg

SD-200C-24 200 Watt 36~72V 24V 8.40A 1500V DC 150mV 86% 215 x 115 x 50mm: 1.1kg

SD-200D-24 200 Watt 72~144V 24V 8.40A 1500V DC 150mV 84% 215 x 115 x 50mm: 1.1kg

SD-350B-24 350 Watt 19~36V 24V 14.6A 1500V DC 150mV 80% 215 x 115 x 50mm: 1.1kg

SD-350C-24 350 Watt 36~72V 24V 14.6A 1500V DC 150mV 81% 215 x 115 x 50mm: 1.1kg

SD-350D-24 350 Watt 72~144V 24V 14.6A 1500V DC 150mV 87% 215 x 115 x 50mm: 1.1kg

SD-500L-24 500 Watt 19~72V 24V 21A 2000V DC 150mV 88% 215 x 115 x 50mm: 1.15kg

SD-500H-24 500 Watt 72~144V 24V 21A 2000V DC 150mV 89% 215 x 115 x 50mm: 1.15kg

SD-1000L-24 1000 Watt 19~72V 24V 40A 2000V DC 150mV 88% 295 x 127 x 41mm: 1.95kg

SD-1000H-24 1000 Watt 72~144V 24V 40A 2000V DC 150mV 89% 295 x 127 x 41mm: 1.95kg

Page 45
DRC SECURITY SERIES OF DIN RAIL POWER SUPPLIES FROM 40W TO 100W
AND FULLY ENCLOSED SECURITY SERIES

DRC security series for mounting on TS-35/7.5 or 15 DIN rail.


Single output with battery charger (UPS function).
Input 90~264V AC and 127~370V DC.
Outputs of 13.8V and 27.6V DC.
2 channels, main power and charging circuit.
Alarm signal for AC OK and battery low.
LED indicator for power on.
100% full load burn in test.
3 years warranty.

A comprehensive range of DIN rail mounted power supplies for security applications. These units have a single output voltage of
13.8V for the main power and 13.8V for charging or 27.6V for the main power and 27.6V for charging (2 channels).
They are short circuit, overload, over voltage and battery low protected. They are also battery reverse protected using a fuse.
Cooling is by free air convection.
The DC adjustment range on Channel 1 for 13.8V is 12V~15V and for 27.6V is 24V~30V.
The working temperature is –30 deg C to +70 deg C.
They are designed and approved to safety standards UL 60950-1 and TUV EN 60950-1.

Reference Watts Input Output voltage Tolerance Ripple & Efficiency Dimensions (mm)
voltage and current DC noise LxWxH
Main power
Charging power
DRC-40A 40 Watt 90~264V AC 13.8V 0~2.9A +/-1% 120mV 86% 40 x 90 x 100
127V~370V DC 13.8V 0~1.0A +/-1%
DRC-40B 40 Watt 90~264V AC 27.6V 0~1.45A +/-1% 200mV 87% 40 x 90 x 100
127V~370V DC 27.6V 0~0.5A +/-1%

DRC-60A 60 Watt 90~264V AC 13.8V 0~4.3A +/-1% 120mV 86% 40 x 90 x 100


127V~370V DC 13.8V 0~1.5A +/-1%
DRC-60B 60 Watt 90~264V AC 27.6V 0~2.15A +/-1% 200mV 88% 40 x 90 x 100
127V~370V DC 27.6V 0~0.75A +/-1%
DRC-100A 100 Watt 90~264V AC 13.8V 0~7A +/-1% 120mV 87% 55 x 90 x 100
127V~370V DC 13.8V 0~2.5A +/-1%
DRC-100B 100 Watt 90~264V AC 27.6V 0~3.5A +/-1% 240mV 89% 55 x 90 x 100
127V~370V DC 27.6V 0~1.25A +/-1%

EN 54-4 enclosed security series with battery module.


Using CBI all in one or CB battery charger as shown on next page(s).
With battery module connected for complete security power.
Fully ventilated to IP23 with cable entry.

CBI ‘all-in-one power’ DC power plus battery charger.


From 12V DC 3A to 12V 35A, 24V DC 3A to 20A and 48V DC 5A.
CB battery chargers.
From 12V DC 3A to 12V DC 6A and 24V DC 3A to 24V DC 10A.
Battery modules.
From 12V DC 3.2Ah to 12V 9Ah and 24V 1.2Ah to 24V 12Ah.

Full UPS options available.


CE compliant.

Enclosed security range of AC/DC power units with battery modules fitted.
Type 1 uses CBI ’all-in-one’ DC power supply plus charger and battery module.
Type 2 uses CB DC battery charger and battery module.
Type 3 uses UPS unit and battery module.

For more information please contact our sales department.

Page 46
STOCK RANGE OF SINGLE OUTPUT BATTERY CHARGERS WITH UPS FUNCTION
AND ALL-IN-ONE BATTERY CHARGERS WITH CONTINUITY BACKUP FUNCTION

Single 12V and 24V DC output plus battery charger


(UPS function).

Universal AC input 88~264V AC 47~63Hz: 124~370V DC.


Short circuit, overload and over voltage protected.

Battery low protection.


Cooling by free air convection.

100% burn-in test and full 2 year warranty.

Reference Rated power Output voltages Load & Line Output V Ripple & Output V Efficiency Dimensions (mm)
Watts and currents regulation adjustment noise tolerance WxDxH

AD 55A 55 Watts 1/ 13.8V 4.00A +/-0.5% 12~14.5V DC 100mV p-p +/- 1% 71% 159 x 97 x 38
2/ 13.4V 0.23A Charger
AD 155A 155.Watts 1/ 13.8V 11.5A +/-0.5% 12~14.5V DC 150mV p-p +/- 1% 80% 199 x 110 x 50
2/ 13.3V 0.50A Charger
AD 55B 55 Watts 1/ 27.6V 2.00A +/- 0.5% 24~29V DC 100mV p-p +/- 1% 74% 159 x 97 x 38
2/ 26.5V 0.16A Charger
AD 155B 155 Watts 1/ 27.6V 5.50A +/-0.5% 24~29V DC 150mV p-p +/- 1% 84% 199 x 110 x 50
2/ 27.1V 0.50A Charger

All-in-one single DC output plus battery charger.


With continuity backup function.
AC input 0/115V 0/115V (93~264V) 47~63Hz.
Short circuit, overload, over voltage and reverse battery
protected.

Output signals:
Mains or backup and low battery or faulty battery.

UPS versions from 24V DC 1.5A~10A various inputs.

Cooling by free air convection.


Ambient temperature range –10 to +50 deg C.
3kV isolation voltage.
Efficiency between 76~91% dependant on type.

Reference Input voltage Rated Battery Load Charging Efficiency Dimensions (mm)
and Hz output output output current WxDxH
CBI 123A 0/115/230V 50/60 Hz 12V DC 3A 13.75~14.4V DC 11~13.5V DC 20~100% 81% 65 x 135 x 115
CBI 126A 0/115/230V 50/60 Hz 12V DC 6A 13.75~14.4V DC 11~13.5V DC 20~100% 81% 65 x 135 x 115
CBI 1210A 0/115/230V 50/60 Hz 12V DC 10A 13.75~14.4V DC 11~13.5V DC 20~100% 89% 65 x 135 x 115
CBI 1235A 0/115/230V 50/60 Hz 12V DC 35A 13.75~14.4V DC 11~13.5V DC 20~100% 91% 150 x 115 x 135
CBI 243A 0/115/230V 50/60 Hz 24V DC 3A 27.5~28.8V DC 22~28.8V DC 20~100% 81% 65 x 135 x 115
CBI 245A 0/115/230V 50/60 Hz 24V DC 5A 27.5~28.8V DC 22~28.8V DC 20~100% 82% 65 x 135 x 115

CBI 2410A 0/115/230V 50/60 Hz 24V DC 10A 27.5~28.8V DC 22~28.8V DC 20~100% 83% 100 x 135 x 115
CBI 2420A 0/115/230V 50/60 Hz 24V DC 20A 27.5~28.8V DC 22~28.8V DC 20~100% 91% 150 x 115 x 135
CBI 485A 0/115/230V 50/60 Hz 48V DC 5A 55~57.6V DC 44~57.6V DC 20~100% 83% 100 x 135 x 115
CBI 4810A 0/115/230V 50/60 Hz 48V DC 10A 55~57.6V DC 44~57.6V DC 20~100% 91% 150 x 115 x 135
UPS 242A 0/115/230V 50/60 Hz 24V DC 1.5A 27.5~28.8V DC 22~28.8V DC See data 76% 71 x 95 x 65
UPS 123A 0/115/230V 50/60 Hz 24V DC 3A 27.5~28.8V DC 22~28.8V DC See data 76% 71 x 95 x 65

UPS 2410C 230V 50/60 Hz 24V DC 10A 27.5~28.8V DC 22~28.8V DC See data 81% 135 x 115 x 135

UPS 2410B 400V 50/60 Hz 24V DC 10A 27.5~28.8V DC 22~28.8V DC See data 81% 135 x 115 x 135

Page 47
AC/DC AND DC/DC CONVERTERS
AND AC/DC BATTERY CHARGERS FROM 36 WATTS TO 480 WATTS

AC/DC and DC/DC converters.


Input 24~32V AC 47~63Hz or 33~45V DC.
Outputs from 24V DC 3A to 24V DC 20A.

Power ratings from 72 Watts to 480 Watts.


With 5V, 12V and 48V DC also available.
Protection Class I with provision for earth.

Ambient temperature range 0~50 deg C

A comprehensive range of AC/DC and DC/DC converters with input ranges of 24~32V AC and 33~45V DC. The standard single
output voltage is 24V DC with additional 5V, 12V and 48V DC single outputs also available. The SW range are short circuit and
overload protected with the PFAL range having additional over voltage and parallel operation features.

Reference Output voltage Output Internal Maximum Continuous Dimensions (mm)


and current adjuster input fuse current current W x H x D : (kg)

SW243LC 24V DC 3A None None 3A +/-7% 3A 50 x 95 x 61 : 0.20


SW245HP 24V DC 5A None None 5A +/-7% 3.5A 50 x 95 x 61 : 0.20
SW247HP 24V DC 7A None None 7A +/-7% 5A 70 x 95 x 61 : 0.35
PFAL247 24V DC 7A +/-10% 10A 7A +/-7% 5A 108 x 94 x 63 : 0.40
PFAL2410 24V DC 10A +/-10% 15A 10A +/-7% 7A 124 x 94 x 96 : 0.50
PFAL2415 24V DC 15A +/-10% 20A 15A +/-7% 10A 150 x 115 x 96 : 0.95
PFAL2420 24V DC 20A +/-10% 25A 20A +/-7% 15A 150 x 115 x 96 : 1.15

Battery chargers from 36 Watts to 480 Watts.


Inputs 115V or 230V 47~63Hz.
Outputs of 12V, 24V & 36V DC.

Protection Class I with provision for earth.

Ambient temperature range –10 to +50 deg C.

Isolation voltage 3000V AC.

A comprehensive range of AC/DC battery chargers with inputs of 115V or 240V AC and outputs of either 12V or 24V DC. They are all
short circuit, overload, over voltage and reverse battery protected. The efficiency per unit is 81% to 82%.
All units are fitted with an internal input fuse and they are suitable for jumper charging configuration. The A series have output
signals that include low battery and faulty battery and the CBI 245A and CBI 2410A have mains or backup power output signals.
The ALC series have no output signals. The rated input voltage range is 93~264V AC for all types.

Reference Output voltage Output Boost Trickle Maximum Dimensions (mm)


and current adjuster charge charge charging current WxHxD

CB 123ALC 12V DC 3A None 14.4V DC 13.75V DC 3A +/- 5% 45 x 100 x 100mm

CB 123A 12V DC 3A 20%~100% 14.4V DC 13.75V DC 3A +/- 5% 45 x 100 x 100mm

CB 126A 12V DC 6A 20%~100% 14.4V DC 13.75V DC 6A +/- 5% 45 x 100 x 100mm

CB 243ALC 24V DC 3A None 28.8V DC 27.5V DC 3A +/- 5% 45 x 100 x 100mm

CB 243A 24V DC 3A 20%~100% 28.8V DC 27.5V DC 3A +/- 5% 45 x 100 x 100mm

CB 245A 24V DC 5A 20%~100% 28.8V DC 27.5V DC 5A +/- 5% 65 x 115 x 135mm

CB 2410A 24V DC 10A 20%~100% 28.8V DC 27.5V DC 10A +/- 5% 100 x 115 x 135mm

CB 2420A 24V DC 20A 20%~100% 28.8V DC 27.5V DC 20A +/- 5% 150 x 115 x 135mm

CB 363AV 36V DC 3A 20%~100% 43.2V DC 41.25V DC 3A +/- 5% 45 x 110 x 105mm

Page 48
UNREGULATED AND SMOOTHED 24V DC POWER SUPPLIES
WITH BOTH SINGLE OR THREE PHASE INPUTS

Unregulated and smoothed DC outputs.

Single and three phase inputs with 24V DC output.

Single phase input with 1A to 16A DC output with ripple <5%.


Three phase input with 6A to 40A DC output with ripples <6% & <3%.

Off load voltage <30.2V with 6% line over voltage.


Full load voltage >20.4V with 10% line under voltage.
145-125
DIN rail mounting option from 1A~2.5A DC.

Three ranges of unregulated 24V DC conventional power supplies.


A single phase range with either 230V +/- 5% or 400V +/- 5% inputs and a 24V DC output from 1A to 6A with 5% ripple.
A single phase range with dual inputs of 230/400V +/- 5% and a 24V DC output from 10A to 16A with 5% ripple.
A three phase range with 400V +/- 5% inputs and a 24V DC output from 6A to 40A with either 6% or 3% ripple.
The transformers are to VDE 0551 Class 1 construction and are suitable for ambient temperatures of up to 60 deg C. The connections
are touch protected screw terminals and all units are designed for chassis mounting. Also single phase units up to 2.5A DC are
suitable for DIN rail mounting using of an easy fit DIN rail adaptor.

Reference: Reference: Output Dimensions FC Kg


Input voltage Input voltage LxWxH LxWx
230V 1ph +/- 5% 400V 1ph +/- 5% mm diameter mm Images are not to scale
145-113 145-113.001 24V DC 1.0A 78 x 70 x 112 65 x 52 x 4.8 1.3
145-114 145-114.001 24V DC 1.6A 78 x 70 x 112 65 x 52 x 4.8 1.3
145-125 145-125.001 24V DC 2.5A 84 x 86 x 120 70 x 70 x 4.8 2.2
145-116 145-116.001 24V DC 3.15A 84 x 86 x 120 70 x 70 x 4.8 2.2
145-117 145-117.001 24V DC 4.0A 105 x 96 x 140 88 x 71 x 5.3 3.0
145-119 145-119.001 24V DC 6.0A 105 x 96 x140 88 x 71 x5.3 3.6

Reference: Output Dimensions FC Kg


Input voltage LxWxH LxWx
230/400V 1ph +/- 5% mm diameter mm 137-106

148-110 24V DC 10.0A 126 x 105 x 186 90 x 86 x 5.8 6.0


148-116 24V DC 16.0A 195 x 112 x 210 123 x 90 x 7.0 14.8

Reference: Reference: Output Dimensions FC Kg


Input voltage Input voltage LxWxH LxWx
400V 3ph 400V 3ph mm diameter mm
+/- 5% +/- 5%
6% ripple 3% ripple

137-106 137-106.200 24V DC 6.0A 125 x 80 x 154 100 x 56 x 5 3.1


137-110 137-110.200 24V DC 10.0A 156 x 140 x 105 140 x 112 x 4.3 5.5

137-116 137-116.200 24V DC 16.0A 185 x 165 x 120 167 x 132 x 7 8.1 148-116

137-125 137-125.200 24v DC 25.0A 185 x 165 x 190 167 x 132 x 7 12.1

137-140 137-140.200 24V DC 40.0A 215 x 212 x 185 194 x 157 x 7 18.1

Reference: Input voltage Output Dimensions FC Kg


200/230/400/415/ LxWxH LxWx
440/460/480/500V 3ph mm diameter mm
3% ripple

137-106.201 24V DC 6.0A 125 x 80 x 154 100 x 56 x 5 3.6


137-110.201 24V DC 10.0A 156 x 140 x 105 140 x 112 x 4.3 6.0
137-116.202 24V DC 16.0A 185 x 165 x 120 167 x 132 x 7 8.5
137-125.201 24V DC 25.0A 185 x 165 x 190 167 x 132 x 7 12.7
137-140.201 24V DC 40.0A 215 x 212 x 185 194 x 157 x 7 19.0 137-140

Page 49
STOCK RANGE OF SINGLE OUTPUT 24V DC SWITCHED-MODE POWER SUPPLIES
WITH BOTH SINGLE OR THREE PHASE INPUTS & SPECIAL OPTIONAL FUNCTIONS

Competent COSMO slimline series.


Slim construction to maximise space on the DIN rail.
Covered input connections and range of 5A ~20A at 24V DC.
Power factor correction to EN 61000-3-2.
Extended output voltage range.
Balanced load sharing when wired in parallel.
Low ripple < 50mV.
Overload indicator.

Approvals include UL and CUL.


Special optional functions.

The Competent COSMO slim line series offers the design engineer the optimum in design excellence for a comprehensive range
of 24V DC applications.
The slim construction maximises the space on the DIN rail and units from 24V DC 5A to 20A have a unique termination cover to
protect the connections and the wiring. The terminations are a cage clamp type for ease of wiring and consistent reliability. All units
comply with EN 61000-3-2 for the latest power factor correction requirements. The DC output voltage is adjustable as shown in the
table below, and when they are wired in parallel the load is balanced automatically between the units. The output ripple is below
50mV and in the event of an overload a red LED indicator is activated. Special optional functions include remote ON/OFF control,
overload signalling and power failure signalling as well as having the option of either hiccup mode or turn-off mode for the output
overload protection. The units are fully approved to the highest standards including UL, CUL and LGA.

Reference Input range Output W D H Weight Typical Output adjustment range

149002-21001 94-265V 1ph 24V DC 1.25A 45 105 72 0.20 85% 23.3V to 24.7V DC
149001-31001 94-265V 1ph 24V DC 2.0A 45 105 72 0.20 89% 23.3V to 24.7V DC
149001-51056 94-265V 1ph 24V DC 5.0A 70 139 132 0.90 89% 22V to 30V DC (30V max. 4A)
149001-51111 93-132V & 187-265V 1ph 24V DC 10A 70 164 147 1.2 90% 22V to 30V DC (30V max. 8A)
149001-61114 190-265V 1ph 24V DC 20A 86 173 227 2.0 89% 22V to 29V DC (29V max. 16A)
149001-61116 340-550V 3ph 24V DC 20A 86 173 227 2.0 89% 22V to 29V DC (29V max.16.5A)

Competent COSMO conventional series


High quality and high reliability

From 2.5A to 40A at 24V DC


In both single and 3 phase inputs
Overload indicator
Safety standard to IEC 950, EN 60950 and VDE 0805
RFI suppression to EN 55011/ EN 5022 Class B
Noise immunity to EN 50082-1/-2

The Competent Cosmo conventional 24V DC range offer high specification and proven reliability.
The range has been extensively used throughout the world and has a proven track record for long term reliability and high q uality.
Units are available from 24V DC 2.5A to 40A and are offered in both 1ph or 3ph inputs. RFI suppression is to EN 55011/ EN 55022
Class B and noise immunity is to EN 50082-1/-2. They are fully protected against overload and short circuit and are in accordance to
IEC 950, EN 60950 and VDE 0805 safety requirements. All units have an inbuilt on indicator.

Reference Input range Output W D H Weight Typical Output adjustment range


47-63Hz (mm) (kg) efficiency
149001-41001 94-265V 1ph 24V DC 2.5A 108 65 123 0.60 86% 22.5V to 27.5V DC
149001-51051 94-265V 1ph 24V DC 5.0A 147 86 123 0.80 86% 22.5V to 27.5V DC
149001-51101 97-132V & 195-265V 1ph 24V DC 10A 205 86 123 1.20 89% 22.5V to 27.5V DC
149001-51301 340-550V 3ph 24V DC 10A 81 160 153 1.40 90% 23V to 30V DC
149001-61103 195-265V 1ph 24V DC 20A 240 86 153 1.90 88% 22.5V to 27.5V DC
149001-61101 340-550V 3ph 24V DC 20A 240 86 153 1.90 90% 22.5V to 27.5V DC
149001-71101 340-550V 3ph 24V DC 40A 292 130 195 3.60 90% 22.5 to 27.5V DC

Page 50
CONSTANT VOLTAGE TRANSFORMERS (CVT)
FROM 100VA TO 15KVA 1PH AND 9KVA TO 45KVA 3PH

Constant voltage transformers from 100VA to 15kVA single


phase at unity power factor (1 pf).

Any nominal input and output up to 600V AC 1ph.


Mains voltage and frequency to customer specification.

Termination options include terminals or plug and socket.


High Mean Time Between Failure (MTBF) of over 200,000 hours
(22.8 years).

Constant voltage transformers are ideal maintenance free solutions for loads that can suffer erratic operation or be damaged by
electrical noise, local transients, mains power sags, surges or brownouts. They offer galvanic isolation and high common and
normal mode noise attenuation, with a sine wave output regardless of input waveform.
Even with an input variation of +/-15% these units stabilise this to +/-3% of the nominal output voltage. When faced with an extreme
transient such as a lightning strike, the CVT will protect both itself and any connected load. They also generate a perfect sine wave
output even when fed by square or quasi-square wave form sources.

For full technical data on any of these products please contact our sales department.

Constant voltage transformers from 9kVA to 45kVA three


phase at unity power factor (1 pf).

Any nominal input & output up to 600V AC 3ph with star output.
Mains voltage and frequency to customer specification.

Connections are via terminals.


High Mean Time Between Failure (MTBF) of over 200,000 hours (22.8
years).

Reference VA rating at No of Connections Net weight Dimensions


1.0 pf phases In kg W x D x H (mm)

AGT 100 100VA 1ph Terminals or plug and socket 7.5 146 x185 x 190
AGT 250 250VA 1ph Terminals or plug and socket 12.5 185 x 230 x 190
AGT 450 450VA 1ph Terminals or plug and socket 18 185 x 250 x 210
AGT 650 650VA 1ph Terminals or plug and socket 22 185 x 280 x 210
AGT 1000 1kVA 1ph Terminals or plug and socket 33 185 x 320 x 210
AGT 1300 1.3kA 1ph Terminals or plug and socket 37 268 x 400 x 290
AGT 1600 1.6kVA 1ph Terminals or plug and socket 42 268 x 400 x 290
AGT 2000 2kVA 1ph Terminals or plug and socket 63 268 x 500 x 290
AGT 2500 2.5kVA 1ph Terminals or plug and socket 72 268 x 500 x 290
AGT 3000 3kVA 1ph Terminals 89 405 x 637 x 455
AGT 4000 4kVA 1ph Terminals 100 405 x 637 x 455
AGT 5000 5kVA 1ph Terminals 133 405 x 637 x 610
AGT 7000 7kVA 1ph Terminals 168 405 x 637 x 610
AGT 8000 8kVA 1ph Terminals 194 405 x 637 x 765
AGT 10000 10kVA 1ph Terminals 202 405 x 637 x 765
AGT 12500 12.5kVA 1ph Terminals 243 405 x 637 x 920
AGT 15000 15kVA 1ph Terminals 268 405 x 637 x920
ATT 9000 9kVA 3ph Terminals 410 650 x 1325 x 773
ATT 12000 12kVA 3ph Terminals 485 650 x 1325 x 773
ATT 15000 15kVA 3ph Terminals 530 650 x 1325 x 773
ATT 18000 18kVA 3ph Terminals 575 650 x 1325 x 773
ATT 21000 21kVA 3ph Terminals 680 650 x 1325 x 773
ATT 24000 24kVA 3ph Terminals 745 650 x 1325 x 773
ATT 30000 30kVA 3ph Terminals 785 650 x 1325 x 773
ATT 37500 37.5kVA 3ph Terminals 864 650 x 1325 x 773
ATT 45000 45kVA 3ph Terminals 864 650 x 1325 x 773

Page 51
LINE INTERACTIVE UNINTERRUPTIBLE POWER SUPPLIES (UPS)
FROM 400VA TO 2000VA

AVR boost and buck.


Cold start function.
Smart RS232/USB interface for power management.
Built-in self diagnostic function.
Modem/LAN internet protection.
Compatible with generator set (option).
LCD or LED display options.
Fastest charging capacity.
Auto charging at off mode.
Auto re-start function.

The line interactive range of uninterruptable power supplies are designed to offer total power protection to a broad range of
commercial and industrial environments. They provide clean and reliable backup power to ensure continued data integrity and
optimum performance under a wide range of mains power conditions. This high level of power protection can be incorporated
with the advance power and management diagnosis software package that will allow your IT manager of systems integrator to
remotely monitor and manage both the UPS and the network server.
Two input voltage ranges are available, 220~240V (as standard) and 110~120V (voltage range 81~145V AC). The transfer time
is typically 2~6ms and 10ms maximum. The wave form in battery mode is simulated sine wave. The output AC voltage
regulation is +/-10% and the output frequency range is +/-1Hz. The typical recharging time is 6~8 hours recovering to 90%
capacity.
All types have overload and overcharge protection and have a noise level less than 40dB.
Management data is via the USB/RS-232 port and it supports Windows 2000/2003/XP/Vista 2008/ Windows 7, Unix and MAC.
The operational environment has a humidity range of 0~90% RH at 40 deg C (non condensing).
Alarm modes for all types are as follows:
Battery mode Sounds every 10 seconds
Low battery Sounds every second
Overload Sounds every 0.5 second
Battery replacement alarm Sounds every 2 seconds
Fault Sounds continuously

Reference VA Watts Selectable Input voltage Battery type and Dimensions Weight in kg
rating input voltage and range number of D x W X H (mm)
Hz auto sensing batteries

MICRO 400 400 240 220/230/240V AC 162~290V AC 12V 4.5Ah x 1 298 x 101 x 142 3.55
LED or LCD 50/60Hz

MICRO 600 600 360 220/230/240V AC 162~290V AC 12V 7Ah x 1 298 x 101 x 142 4.25
LED or LCD 50/60Hz

MICRO 800 800 480 220/230/240V AC 162~290V AC 12V 9Ah x 1 298 x 101 x 142 4.9
LED or LCD 50/60Hz

MICRO 1000 1000 600 220/230/240V AC 162~290V AC 12V 7Ah x 2 338 x 149 x 162 7.8
LED or LCD 50/60Hz

MICRO 1200 1200 720 220/230/240V AC 162~290V AC 12V 7Ah x 2 338 x 149 x 162 8.0
LED or LCD 50/60Hz

MICRO 1500 1500 900 220/230/240V AC 162~290V AC 12V 9Ah x 2 380 x 158 x 198 11.1
LED or LCD 50/60Hz

MICRO 2000 2000 1200 220/230/240V AC 162~290V AC 12V 9Ah x 2 380 x 158 x 198 11.5
LED or LCD 50/60Hz

Indicators Types: Micro 400, Micro 600, Types: Micro 1500 and Micro 2000
Micro 800, Micro 1000 and
Micro 1200

AC mode Green LED illuminated The 5th green LED illuminated, (the 1st to 4th green LED illuminated to indicate load level)
LED 1 (green): >100% load level, LED 2 (green): >75% load level,
LED 3 (green): >50% load level, LED 4 (green): >25% load level.

Battery mode Amber LED flashing The 5th green LED blinking, (the 1st to 4th green LED illuminated to indicate battery
capacity)
LED 1 (green): battery voltage >25V, LED 2 (green): battery voltage >23V, LED 3 (green):
battery voltage >22V, LED 4 (green): battery voltage >21V.

Page 52
C-TEC SERIES OF DC BUFFER MODULES
WITHOUT BATTERIES USING ULTRA CAPACITOR TECHNOLOGY

Battery free DC buffer modules utilizing Ultra capacitors.


Maintenance free with compact design to IP20.
With up to 20 years life depending on temperature.

Wide operating temperature range –40 deg C to +60 deg C.


No gas emissions and can be used in enclosed cabinets.

Fast recharge cycle after discharge.


Deep discharge protection.

The C-TEC series of DC buffer modules works using Ultracapacitors for energy storage within the housing. If the DC power is
interrupted the energy stored in the Ultra capacitors is released. The load is energised from the buffer module until it is discharged.
The back-up time is dependant on the state of charge of the capacitors and on the discharge current.
Compared with normal buffer modules with capacitors the new C-TEC range offers longer back up times.
This is dependant on the energy of the capacitors and is calculated as follows:

energy 10000 Joule


Back up time = ————————— ; with fully charged capacitors ——————- = 50 seconds
voltage x current 24V x 10A

12V DC and 24V DC input/output


Reference Nominal Accumulated Output V in Nominal Dimensions
input V energy in Ws buffer Output in mm
mode current D x W x H: (kg)

CTEC 2403-05 24V DC +/-20% 500 23.2V DC 3A 93 x 60 x 116: 0.5


CTEC 2403-1 24V DC +/-20% 1000 23.2V DC 3A 93 x 60 x 116: 0.55
CTEC 1203-05 12V DC +/-20% 500 11.75V DC 3A 93 x 60 x 116: 0.5
CTEC 1203-1 24V DC 1000 11.75V DC 3A 93 x 60 x 116: 0.55
CTEC 2405-5 24V DC 5000 23.2V DC 5A 165 x 114 x 145: 1.8
CTEC 2408-20 24V DC 20000 23.2V DC 8A 165 x 184 x 145: 2.8
CTEC 2410-1 24V DC 1000 23.2V DC 10A 165 x 70x 138: 0.3
CTEC 2410-10 24V DC 10000 23.2V DC 10A 165 x 114 x 145: 2.1
CTEC 2420-8 24V DC 8000 23.2V DC 20A 192 x 84 x 192: 1.8

AC input with 12V DC and 24V DC output

Reference Nominal Accumulated Output V in Nominal Dimensions


input V energy in Ws buffer Output in mm
mode current D x W x H: (kg)

ACCTEC 2403-1 115-230V AC 1ph 1000 23.2V DC 3A 153 x 72 x 130: 1.2


ACCTEC 1203-1 115-230V AC 1ph 1000 12.2V DC 3A 153 x 72 x 130: 0.8
ACCTEC 2410-1 115-230V AC 1ph 10000 23.2V DC 10A 153 x 72 x 130: 0.8
ACCTEC 2420-8 350-550V AC 3ph 8000 23.2V DC 20A 192 x 170 x 198: 0.8

Capacitor extension modules

Reference Nominal Accumulated Input Nominal Dimensions


input V energy in Ws voltage Output in mm
range current D x W x H: (kg)

CEM 1 24V DC 1kJ 1000Ws 0-26.4V DC 3A DC 92.5 x 60 x 116: 0.85


CEM 2 24V DC 2kJ 2000Ws 0-26.4V DC 3A DC 92.5 x 60 x 116: 1.0
CEM 8 24V DC 8kJ 8000Ws 0-26.4V DC 20A DC 192 x 84 x 192: 1.4
CEM 16 24V DC 16kJ 1600Ws 0-26.4V DC 20A DC 192 x 84 x 192: 1.9
CEM 12V06 12V DC 0.6kJ 600Ws 0-13.2V DC 3A DC 92.5 x 60 x 116: 0.7
CEM 12V12 12V DC 1.2kJ 1200Ws 0-13.2V DC 3A DC 92.5 x 60 x 116: 0.95

Page 53
AKKUTEC RANGE OF ONLINE DC-UPS
FROM 48WATTS TO 960 WATTS

Operation modes:
Stand by parallel operation, buffer battery system.

Battery management by micro processor.

Isolation to EN 61558-2-17 and Class I protection.


EMC to EN 55011 and EN 50082-2.

Battery test and circuit disconnect functions.

The AKKUTEC range of online DC-UPS modules work using external batteries for energy storage.
Ranges include 24V 2A~20A DC with 1ph input, 24V 20~40A DC with 3ph input, 24V 2.85A DC with 24V DC input and 12V
2.85A~10A DC with 1ph input.
If the DC power is interrupted the energy stored in the batteries is released. The load is energised from the battery bank until it is
discharged. The backup time is dependant on the batteries used. The modules incorporate potential free output control and LEDs in-
dicate mains operation and general errors. The battery management is controlled by micro processor.
The output characteristic is to I/U DIN 41773-1 and leakage current is <3.5mA.

Please contact or sales department for more information and dimensions.


1ph AC input and 24V DC input 24V DC output
Reference Input voltage Rated Load Max Weight
output V + current charging (kg)
charging V DC current

AKKUTEC 115~230V 24V DC 2A 2.1A 0.3


2402-0 +/-15% 50/60Hz 26.4V...19V

AKKUTEC 230V 24V DC 2.85A 2.85A 0.35


2403-0 +/-15% 50/60Hz 26.4V...19V
AKKUTEC 24V DC 24V DC 2.85A 2.85A 0.35
2403-DC +/-15% 26.4V...19V

AKKUTEC 115~230V 24V DC 5A 7A 1.1


2405-0 +/-15% 50/60Hz 26.4V...19V

AKKUTEC 115~230V 24V DC 10A 11A 1.6


2410-0 +/-15% 50/60Hz 26.4V...19V

AKKUTEC 230V 24V DC 20A 21A 2.4


2420-0 +/-15% 50/60Hz 26.4V...19V

3ph AC input 24V DC output


Reference Input voltage Rated Load Max Weight
output V + current charging (kg)
charging V DC current

AKKUTEC 3 x 400~500V 24V DC 20A 22A 2.6


2420-3 -15% +10% 50/60Hz 26.4V...19V
AKKUTEC 3 x 400~500V 24V DC 40A 42A 3.0
2440-3 -15% +10% 50/60Hz 26.4V...19V

1ph AC input 12V DC output

Reference Input voltage Rated Load Max Weight


output V + current charging (kg)
charging V DC current

AKKUTEC 230V 12V DC 2.85A 2.85A 0.35


1203 +/-15% 50/60Hz 9.9...13.2V

AKKUTEC 115~230V 12V DC 5A 6A 1.1


1205 USB +/-15% 50/60Hz 9.9...13.2V

AKKUTEC 230V 12V DC 10A 12A 1.6


1210 +/-15% 50/60Hz 9.9...13.2V

Page 54
STOCK RANGES OF SINGLE PHASE EMC FILTERS
FROM 5A TO 65A

Comprehensive ranges of single phase EMC filters for immediate Images are not to scale
despatch on a next day delivery.

Single phase filters from 6A to 65A, in both single and two stage
configurations 50/60Hz.

Designed for wide range of industrial power applications.

Comprehensive ranges of single phase RFI filters are available to assist


design engineers to meet the various requirements of the relevant EMC
legislation.

These single phase units are from 5 Amps to 65 Amps and are available in
a variety of case, type and termination options.
Standard voltage options are up to 250V AC .

The FIN ranges are from FIN 33 to FIN 50, in ascending attenuation levels.
Frequency is 50/60Hz with operational temperature range of –25 deg C
to +85 deg C.

The EMK range are specially designed for industrial frequency inverters,
drive systems and industrial power applications. For full technical
specifications go to www.emikon.com.

Reference Current rating Voltage AC Terminations Leakage Description Dimensions


& phases current L x W x H mm

FIN 33.006.F 6A 250V 1ph Amp tags <1.5mA Single stage 63 x 63 x 29

FIN.35.005.F 5A 250V 1ph Amp tags <1.5mA Two stage 85 x 78 x 29

FIN.35.010.F 10A 250V 1ph Amp tags <1.5mA Two stage 85 x 78 x 33

FIN.40.005.F 5A 250V 1ph Amp tags <1.5mA Two stage 85 x 78 x 29

FIN.40.010.F 10A 250V 1ph Amp tags <1.5mA Two stage 85 x 78 x 33

FIN.40.016.F 16A 250V 1ph Amp tags <1.5mA Two stage 97 x 78 x 40

FIN.40.24.M 24A 250V 1ph Terminal blocks <1.5mA Two stage 70 x 78 x 50

FIN.50.005.F 5A 250V 1ph Amp tags <2.2mA Two stage 85 x 78 x 40

FIN.50.010.F 10A 250V 1ph Amp tags <2.2mA Two stage 97 x 78 x 50

FIN.50.016.F 16A 250V 1ph Amp tags <2.2mA Two stage 105 x 112 x 45

FIN.50.24.M 24A 250V 1ph Terminal blocks <2.2mA Two stage 105 x 112 x 50

EMK 1010 10A 250V 1ph Terminal blocks <3.2mA Two stage 150 x 55 x 45

EMK 1015 15A 250V 1ph Terminal blocks <3.2mA Two stage 150 x 55 x 45

EMK 1020 20A 250V 1ph Terminal blocks <3.2mA Two stage 170 x 80 x 55

EMK 1035 35A 250V 1ph Terminal blocks <3.2mA Two stage 170 x 80 x 55

EMK 1065 65A 250V 1ph Terminal blocks <3.2mA Two stage 250 x 110 x 60

Page 55
STOCK RANGES OF THREE PHASE EMC FILTERS
FROM 7A TO 2500A

Comprehensive ranges of three phase EMC filters for Images are not to scale
immediate despatch on a next day delivery.

MLC range of three phase filters in 6A to 180A 480V 50/60Hz.


With terminal block connections and slimline construction.
VPE range of three phase filters in 150A to 2500A
at 480V 50/60Hz.

Comprehensive ranges of three phase RFI filters are available to assist


design engineers to meet the various requirements of the relevant EMC
legislation. Three phase units are from 7 Amps up to 2500 Amps in MLC
bookend and VPE shoebox styles. Termination options include terminal
blocks and high current copper bus bar connections.

Standard voltage options are 480V AC with the VPE series in 690V and
760V versions.

The MLC are high attenuation filters that have low leakage current. They
have a slim line construction, low weight and good thermal dissipation.

The VPE range from 180A~2500A, is one of the most compact ranges of
high current filters in the whole EMC market. They are also high
attenuation filters that have low leakage current.

For full technical specifications go to www.emikon.com.

Reference Current rating Voltage AC Terminations Leakage current Power loss Dimensions
& phases L x W x H mm
MLC 3007 7A 480V 3ph Terminal blocks 0.5mA~27mA 4.5W 190 x 40 x 70
3 wire + earth
MLC 3016 16A 480V 3ph Terminal blocks 0.5mA~27mA 9.0W 250 x 45 x 70
3 wire + earth
MLC 3030 30A 480V 3ph Terminal blocks 0.5mA~27mA 14W 270 x 50 x 85
3 wire + earth
MLC 3042 42A 480V 3ph Terminal blocks 0.5mA~27mA 19W 310 x 50 x 85
3 wire + earth
MLC 3055 55A 480V 3ph Terminal blocks 0.5mA~27mA 20W 250 x 85 x 90
3 wire + earth
MLC 3075 75A 480V 3ph Terminal blocks 0.5mA~27mA 20W 270 x 80 x 135
3 wire + earth
MLC 3100 100A 480V 3ph Terminal blocks 0.5mA~130mA 36W 270 x 90 x 150
3 wire + earth
MLC 3130 130A 480V 3ph Terminal blocks 0.5mA~130mA 40W 270 x 90 x 150
3 wire + earth
MLC 3180 180A 480V 3ph Terminal blocks 0.5mA~130mA 61W 380 x 120 x 170
3 wire + earth

VPE 3150/B 150A 480V 3ph Busbars <6mA at 500V AC 28W 260 x 170 x 120
3 wire + earth
VPE 3180/B 180A 480V 3ph Busbars <6mA at 500V AC 38W 260 x 170 x 120
3 wire + earth
VPE 3250/B 250A 480V 3ph Busbars <6mA at 500V AC 57W 300 x 190 x 116
3 wire + earth
VPE 3320/B 320A 480V 3ph Busbars <6mA at 500V AC 40W 300 x 260 x 116
3 wire + earth
VPE 3400/B 400A 480V 3ph Busbars <6mA at 500V AC 50W 300 x 260 x 116
3 wire + earth
VPE 3600/B 600A 480V 3ph Busbars <6mA at 500V AC 65W 300 x 260 x 116
3 wire + earth
VPE 31000/B 1000A 480V 3ph Busbars <6mA at 500V AC 91W 350 x 280 x 166
3 wire + earth
VPE 31600/B 1600A 480V 3ph Busbars <6mA at 500V AC 180W 400 x 300 x 166
3 wire + earth
VPE 32500/B 2500A 480V 3ph Busbars <6mA at 500V AC 400W 600 x 360 x 200
3 wire + earth

Page 56
GREEN SECTION

ETE is a leading UK transformer manufacturer as well as a key national distributor of a comprehensive range of thermal
management products for electrical enclosures and control panels.
Our ranges of thermal management products are one of the most comprehensive and competitive in the whole UK with
many units available from stock on a next day delivery.

Contents summary

Thermal management
products

 AC and DC fans open types

 Fan guards for AC & DC fans

 Filter fans and exhaust filters to IP54

 Roof fans and panel top ventilators

 Thermostats (single and double pole)

 Electronic thermostats, hygrostats


& hygrotherms

 Natural convection anti-condensation


heaters

 Fan assisted anti-condensation heaters

 ….and much more

Page 57 ETE ...........in complete control of power


SUB INDEX

ETE’s thermal management products cover a wide range of application criteria for the cooling and heating of electrical
enclosures. Our technical team is ready to assist in the selection and pricing of your requirements whatever the quantity.
We represent some the worlds key thermal management product manufacturers most of whom give ETE exclusive
rights to distribute their product ranges.
Many product ranges are available ex stock either direct or via our extensive network of UK distributors.

Contents detail

Thermal management products

Page 59 AC and DC cooling fans with airflow rates from 0.74 cu m/minute to 17 cu m/minute

Page 60 Cooling fan plastic guards, filter guards, metal finger guards and mesh guards

Page 61 FK series and LFB series of AC filter fans to IP54

Page 62 FK series of DC filter fans & FK series of exhaust filters & non-stock ranges of AC & DC fans & cross flow fans

Page 63 Enclosure roof fans or top ventilators

Page 64 TSNO & TSNC heating and cooling thermostats and DTS double thermostats

Page 65 ETS electronic thermostat, HGS electromechanical hygrostat and EHGS range of electronic hygrostats

Page 66 HT electromechanical hygrotherms, EHGT electronic hygrotherm and DCSW switch module

Page 67 Anti-condensation heaters 10 Watts to 150 Watts for enclosures and control panels

Page 68 Fan assisted anti-condensation heaters from 800 Watts to 1500 Watts for enclosures and control panels

Page 58 ETE ...........in complete control of power


AC AND DC COOLING FANS
WITH AIRFLOW RATES FROM 0.74 CU M/MIN TO 17 CU M/MIN.

High quality, economy AC and DC cooling fans.

AC in either 115V~120V or 230~240V 50/60Hz supplies.


DC in either 12V DC or 24V DC supplies.

Housing in thermoplastic PBT, UL 94V-0 material or die cast aluminium.


Impeller in thermoplastic PBT, UL 94V-0 material or black flame retardant
polycarbonate.

Minimum operating temperature range –10 deg C to +70 deg C.

DC range of cooling fans from 1.13 cu m/minute to 4.76 cu m/minute airflow rates. Images are not to scale
Housing and impeller in thermoplastic PBT, UL 94V-0 material.
Insulation resistance 10 meg Ohms/min @ 500V DC from frame to terminals.
Dielectric strength 5mA maximum at 500V AC 60Hz for 1 minute from frame to terminals.

Reference Voltage and Terminals Ball or Airflow Airflow Noise in Size


current sleeve cu ft/ Cu m/ dB (A) WxHxD
bearing minute minute at 1m in mm

D8025.12 12V DC 0.20A Cables Ball 40 1.13 35 80 x 80 x 25


D8025.24 24V DC 0.12A Cables Ball 40 1.13 35 80 x 80 x 25

D12025.12 12V DC 0.38A Cables Ball 88.3 2.50 48 120 x 120 x 25


120 series AC & DC fans
D12025.24 24V DC 0..24A Cables Ball 88.3 2.50 48 120 x 120 x 25

D12038.12 12V DC 0.32A Cables Ball 168 4.76 50 120 x 120 x 38

D12038.24 24V DC 0.18A Cables Ball 168 4.76 50 120 x 120 x 38

AC range of cooling fans from 0.74 cu m/minute to 17 cu m/minute airflow rates.


Housings: A80, A120, A150, A172 die cast aluminium and impeller in thermoplastic
PBT UL 94V-O. Housing: A250 die cast aluminium and impeller in black flame retardant
polycarbonate. Insulation Class B.
Dielectric strength 1500V AC for 1 minute from frame to terminals.

150 series AC fans


Reference Voltage and Terminals Ball or Airflow Airflow Noise in Size
current at sleeve cu ft/ Cu m/ dB (A) WxHxD
50/60 Hz bearing minute minute at 1m in mm

A8038.115 115V 0.11A Cables Ball 26/32 0.74/0.91 33/36 80 x 80 x 38

A8038.230 230V 0.056A Cables Ball 26/32 0.74/0.91 33/36 80 x 80 x 38

A12025.115 115V 0.15A Terminals Ball 70/81 1.90/2.20 38/42 120 x 120 x 25

A12025.230 230V 0.07A Terminals Ball 70/81 1.90/2.20 38/42 120 x 120 x 25
A12038.115 115V 0.15A Terminals Ball 60/65 1.71/1.84 36/38 120 x 120 x 38

A12038.115S 115V 0.15A Terminals Sleeve 60/65 1.71/1.84 36/38 120 x 120 x 38
172 series AC fans
A12038.230 230V 0.07A Terminals Ball 60/65 1.71/1.84 36/38 120 x 120 x 38

A12038.230S 230V 0.07A Terminals Sleeve 60/65 1.71/1.84 36/38 120 x 120 x 38

A15055.115 115V 0.32A Terminals Ball 200/240 5.66/6.79 50/53 150 diam. x 55

A15055.230 230V 0.146A Terminals Ball 200/240 5.66/6.79 50/53 150 diam. x 55

A17251.115 115V 0.22A Terminals Ball 190/235 5.40/6.70 55/59 172 diam. x 51

A17251.230 230V 0.11A Terminals Ball 190/235 5.40/6.70 55.59 172 diam. x 51

A25489.115 115V 0.23A Terminals Ball 600/665 17.0/18.8 50/52 254 diam. x 89

A25489.230 230V 0.15A Terminals Ball 600/665 17.0/18.8 50/52 254 diam. x 89 254 series AC fans

Page 59
COOLING FAN PLASTIC GUARDS,FILTER GUARDS
METAL FINGER GUARDS AND MESH GUARDS

A comprehensive stock range of fan accessories for AC and DC stock


fans including plastic fan guards, filters guards, metal finger guards and
mesh guards.

Metal mesh guards can be used for protection and/or EMC grounding. For
fans sizes from 80mm x 80mm square and up to 150mm diameter.

Plastic and metal finger guards are used for contact protection.
Plastic fan guards with filter media fitted are used for dust protection with
replaceable filter mats.

A standard stock range of AC axial fan accessories, to compliment the stock range of Images are not to scale
cooling fans. These units are held in stock and are available for immediate despatch.

As well as standard stock ranges of cooling fan accessories, there is a wide range of
non-stock accessories also available.

Reference Description For fan Size mm

PG 80 Plastic guard 80 x 80 x 38 80 x 80

PG 120 Plastic guard 120 x 120 x 38 120 x 120 FM 80 replacement filter

PG 150 Plastic guard 150 diameter x 55 D 153 x 180

PFG 80 Plastic filter guard 80 x 80 x 38 80 x 80

PFG 120 Plastic filter guard 120 x 120 x 38 120 x 120

PFG 150 Plastic filter guard 150 diameter x 55 D 153 x 180

GRV 190 Grilled guard for radial fans 170 diameter x 51 D 170 x 13

GRV 250 Grilled guard for radial fans 254 diameter x 89 D 214 x 15
P120 plastic guard or filter guard
FM 80 Replacement filter mat 80 x 80 x 38 80 x 80

FM 120 Replacement filter mat 120 x 120 x 38 120 x 120

FM 150 Replacement filter mat 150 diameter x 55 D 150 diameter

Reference Description For fan Size mm

MFG 80 Metal finger guard 80 x 80 x 38 71 diameter

MFG 120 Metal finger guard 120 x 120 x 38 105 diameter

MFG 150 Metal finger guard 150 diameter x 55 D 151 diameter MFG metal finger guard

MFG 172 Metal finger guard 172 diameter x 51 D 162 diameter

MFG 254 Metal finger guard 254 diameter x 89 D 222 diameter

Reference Description For fan Size mm

MMG 80 Metal mesh guard 80 x 80 x 38 80 x 80

MMG 120 Metal mesh guard 120 x 120 x 38 120 x 120

MMG 150 Metal mesh guard 150 diameter x 55 153 x 180 MMG metal mesh guard

Page 60
FK SERIES AND LFB SERIES OF AC FILTER FANS TO IP54

FK and LFB series of standard stock AC filter fans to IP54.


LFB series with reduced depth of 130mm.

With airflow rates from 20 cu m/hr to 1200 cu m/hr (free blowing)


and with 15 cu m/hr to 680 cu m/hr with exhaust filters fitted.

Axial fans: AC self-starting, screened, magnetic pole motor.


Axial fans: DC direct current motor.

Temperature range –10 deg C to +55 deg C.


In RAL 7035 colour code.

A comprehensive range of IP54 rated AC axial filter fans with complimenting exhaust filters.
A wide range of airflow rates are covered in both free blowing modes and restricted modes (with exhaust filters fitted).
The LFB range have the advantage of a decreased depth when space is a problem.

Power ratings and noise levels are as follows:

FK 7721.230 12~15W, 41/46 dB (A) and FK 7721.115 12~15W, 41/46 dB (A)


FK 7722.230 22~30W, 46/49 dB (A) and FK 7722.115 22~26W, 41/46 dB (A)
FK 7724.230 47~59W ,54/56 dB (A) and FK 7724.115 43~48W, 54/56 dB (A)
FK 7725.230 46~59W, 54/56 dB (A) and FK 7725.115 42~47W, 54/56 dB (A)
LFB 5000.230 120~138W, 59/61 dB (A) and LFB 5000.115 150~180W, 59/61 dB (A)
FK 7726.230 120~138W, 68/71 dB (A) and FK 7726.115 150~180W, 68/71 dB (A)
LFB 7000.230 120~138W, 59/68 dB (A) and LFB 7000.115 150~180W, 59/68 dB (A)

AC filter fans

Filter fan AC voltage Airflow Airflow cu m/hour with Overall size Cut out
reference at 50/60Hz cu m/hour exhaust WxHxD dimension
and current Free blowing filter fitted in mm W x H in mm
(2 exhaust filters)
FK 7721.230 230V 20/25 15/18 105 x 105 x 60 93 x 93
0.09A
FK 7721.115 115V 20/25 15/18 105 x 105 x 60 93 x 93
0.16A
FK 7722.230 230V 55/66 43/50 150 x 150 x 71 126 x 126
0.12A (48/55)
FK 7722.115 115V 55/66 43/50 150 x 150 x 71 126 x 126
0.24A (48/55)
FK 7724.230 230V 160/180 115/138 250 x 250 x 131 224 x 224
0.26A (130/148)
FK 7724.115 115V 160/180 115/138 250 x 250 x 131 224 x 224
0.42A (130/148)
FK 7725.230 230V 230/265 170/205 250 x 250 x 131 224 x 224
0.28A (200/230)
FK 7725.115 115V 230/265 170/205 250 x 250 x 131 224 x 224
0.53A (200/230)
LFB 5000.230 230V 500/560 360/390 325 x 325 x 130 291 x 291
0.29A (423/490)
LFB 5000.115 115V 500/560 360/390 325 x 325 x 130 291 x 291
0.61A (423/490)
FK 7726.230 230V 1020/1050 550/580 325 x 325 x 167 291 x 291
0.60A (620/680)
FK 7726.115 115V 1020/1050 550/580 325 x 325 x 167 291 x 291
1.70A (620/680)
LFB 7000.230 230V 1200/1350 600/780 325 x 325 x 130 291 x 291
0.46A (680/830)
LFB 7000.115 115V 1200/1350 600/780 325 x 325 x 130 291 x 291
0.95A (680/830)

Page 61
FK SERIES OF DC FILTER FANS AND FK SERIES OF EXHAUST FILTERS
AND NON STOCK RANGES OF AC OR DC FANS AND CROSS FLOW FANS

FK series of DC filter fans to IP54.


With airflow rates from 20 cu m/hr to 230 cu m/hr (free blowing)
and with 15 cu m/hr to 200 cu m/hr with exhaust filters fitted.

FK series of exhaust filters to IP54 for FK & LFB series filter fans.

In RAL 7035 colour code.

Non-stock ranges of AC or DC fans with special features.


Non-stock AC or DC ranges of cross flow fans.

A comprehensive range of IP54 rated DC axial filter fans with complimenting exhaust filters.

A wide range of airflow rates are covered in both free blowing modes and restricted modes (with exhaust filters fitted).
Power ratings and noise levels are as follows: 7721 4.3W 41/46 dB (A), 7722 7.2W 46/49 B (A), 7724 14W 54/56 dB (A),
7725 14W 54/56 dB (A).

FK series of exhaust filters with filter mats to IP54 designed for use with the FK series and LFB series filter fans

DC filter fans

Filter fan DC voltage Airflow Airflow cu m/hour with Overall size Cut out
reference and current cu m/hour exhaust filter fitted WxHxD dimension
Free blowing (2 exhaust filters) in mm W x H in mm

FK 7721.024 24V DC 20/25 15/18 105 x 105 x 60 93 x 93


0.18A
FK 7722.024 24V DC 55/66 43/50 150 x 150 x 71 126 x 126
0.15A (48/55)
FK 7724.024 24V DC 160/180 115 250 x 250 x 131 224 x 224
0.58A (165)
FK 7725.024 24V DC 230/265 170/205 250 x 250 x 131 224 x 224
0.58A (200/230)

Exhaust filters

Exhaust filter For AC fans For DC fan Size Cut out


reference WxhxD dimension
in mm W x H in mm
FK 7721.300 FK 7221.230 and FK 7721.115 FK 7721.024 105 x 105 x 15 93 x 93

FK 7722.300 FK 7222.230 and FK 7722.115 FK 7722.024 150 x 150 x 27 126 x 126

FK 7725.300 FK 7724.230 and FK 7724.115 FK 7724.024 250 x 250 x 31 224 x 224


FK 7225.230 and FK 7725.115 FK 7725.024

FK 7726.300 FK 7226.230 and FK 7726.115 325 x 325 x 36 291 x 291


LFB 5000.230 and LFB 5000.115
LFB 7000.230 and LFB 7000.115

Non stock ranges of fans, filter fans, exhaust filters and cross flow fans

Non stock ranges of AC or DC fans with special features including:


Extended range of fan units with various airflows and speeds from 80mm x 80mm square and up to 254mm in diameter and larger.

Non stock ranges of AC or DC filter fans with special features including:


Extended ranges of filter fans in RAL 7032, filter fans with EMC compliance and filter fans to UL requirements.

Non stock ranges of exhaust filters in RAL 7032 or with EMC compliance
Non stock ranges of high power cross flow fans

For more information please contact our sales department

Page 62
ENCLOSURE ROOF FANS OR TOP VENTILATORS
AND AIR INPUT GRILLS OR FILTER INLETS

F2E series of enclosure roof fans for 230V AC 50/60Hz.

With airflows of 570 cu m/hr to 1200 cu m/hr (free blowing).


and 456 cu m/hr to 960 cu m/hr with air input filters fitted.

Air input filter FK 7726.300 in single or in multiple units.

The fans are axial with capacitor start.

Temperature range –10 deg C to +55 deg C.

In RAL 7035 colour code.

F2E series of enclosure roof fans or top ventilators.

These top ventilators should only be used when the external ambient temperature is lower than the internal enclosure temperature.
The high power centrifugal fan has lower noise levels due to less air flow friction.

These fans do not take up valuable enclosure space and the FK 7726.300 series of exhaust filters can be used with or without the
filter media fitted.

The airflow direction is illustrated and the air inlet should be situated at the base of the enclosure or cabinet.

AC roof or cabinet fans

Roof fan AC voltage Power Airflow Airflow cu m/hour Noise level Overall size
reference at 50/60Hz at 50/60Hz cu m/hour with FK7726.300 in dB (A) WxHxD
and in Watts free blowing exhaust filter fitted in mm
current 50/60Hz 50/60Hz

F2E 190-230-DP 230V 58/75 570/620 456/496 62/64 400 x 350 x 103
0.26A/0.34A

F2E 220-230-DP 230V 85/90 860/900 688/540 73/74 400 x 350 x 103
0.38A/0.0.40A

F2E 225-230-DP 230V 135/200 1200/1340 960/1072 69/71 400 x 350 x 103
0.60A/0.88A

Filter inlet or grill inlet

Filter inlet or For roof fans Overall size


grill inlet W xHxD
reference in mm

FK 7726.300 F2E 190-230-DP 325 x 325 x 36

FK 7726.300 F2E 220-230-DP 325 x 325 x 36

FK 7726.300 F2E 225-230-DP 325 x 325 x 36

Direction of airflow

Page 63
TSNO & TSNC HEATING AND COOLING THERMOSTATS
AND DTS DOUBLE THERMOSTATS

Comprehensive ranges of heating and cooling thermostats and double


thermostats.

TSNO thermostats with normally open contacts for cooling devices.

TSNC thermostats with normally closed contacts for heating devices.

DTS double thermostats with dual contacts for heating and cooling devices.

Large setting range, small size, simple to mount and high switching
performance.

TSN0 060 thermostat


Three ranges of control devices for the accurate control of heat and condensation.
The TSNO and TSNC thermostats operate with a snap action, bi-metallic, two pole contact set .
The DTS double thermostat offers dual control in a single unit, maximising space and simplifying wiring .
Normally closed contacts are used for regulating heaters and normally open contacts are used for regulating cooling fans, heat
exchangers or switching signalling devices. Heaters and cooling equipment can be switched independently with a temperature offset
rather than the usual changeover contacts.
All units are designed of mounting on a 35mm DIN rail.

Reference Contact Temperature Load in A Connections Dimensions Images are not to scale
function range 250V/120V AC HxWxD
deg C or DC 24~72V mm

TSNO 060 Normally open 0 to +60 10A / 15A AC 2 pole 60 x 33 x 43


30W DC
TSNC 060 Normally closed 0 to +60 10A / 15A AC 2 pole 60 x 33 x 43
30W DC
TSNO 1050 Normally open -10 to +50 10A / 15A AC 2 pole 60 x 33 x 43
30W DC
TSNC 1050 Normally closed -10 to +50 10A / 15A AC 2 pole 60 x 33 x 43
30W DC
TSNO 2080 Normally open +20 to +80 10A / 15A AC 2 pole 60 x 33 x 43
30W DC
TSNC 2080 Normally closed +20 to +80 10A / 15A AC 2 pole 60 x 33 x 43
30W DC
Reference Protection Contact Service Colour Weight
type resistance life and casing kg
TSNO 060 IP20 <10m Ohm >100,000 cycles Light grey 0.040
plastic
TSNC 060 IP20 <10m Ohm >100,000 cycles Light grey 0.040 TSNC 060 thermostat
plastic
TSNO 1050 IP20 <10m Ohm >100,000 cycles Light grey 0.040
plastic
TSNC 1050 IP20 <10m Ohm >100,000 cycles Light grey 0.040
plastic
TSNO 2080 IP20 <10m Ohm >100,000 cycles Light grey 0.040
plastic
TSNC 2080 IP20 <10m Ohm >100,000 cycles Light grey 0.040
plastic

Reference Contact Temperature Load in A Connections Dimensions


function range 250V/120V 2.5mm sq HxWxD
deg C cable mm

DTS 060 Normally closed 0 to +60 10A / 15A 2 pole 67 x 50 x 45


Normally open 0 to +60 10A / 15A 2 pole

Reference Protection Contact Service Colour Weight


type resistance life and casing kg

DTS 060 IP20 <10m Ohm >100,000 cycles Light grey 0.090 DTS 060 double thermostat
plastic

Page 64
ETS ELECTRONIC THERMOSTAT
HGS ELECTROMECHANICAL HYGOSTAT AND EHGS RANGE OF ELECTRONIC HYGROSTATS

ETS electronic heating and cooling thermostat for inductive and resistive
loads via internal changeover relay contacts.

HGS electromechanical hygrostats for control of enclosure heaters with


high humidity or low temperature triggering.

EHGS range of electronic hygrostats senses the ambient temperature


and the relative humidity (RH).
There are four types, both 120V and 240V versions, with each available
in two RH ranges.

The ETS 2060 is an electronic thermostat for controlling heating, cooling & signal devices. The adjuster has an inbuilt LED to
indicate the NC contact is closed. The sensor element is a NTC and the reaction time is 5 seconds.

Reference Temperature Max switching Max relay Connections Dimensions


range capacity at output HxWxD
deg C 250V/120V AC AC mm
or 24V DC
ETS 2060 -20 to +60 8A AC 1.6A 5 pole 64.5 x 42 x 38
100W DC 2.5mm sq
Reference Protection Max inrush Service Colour Weight
type current life and casing (kg)
ETS 2060 IP 20 16A AC for 10 >50,000 Light grey plastic 0.070
seconds cycles UL94 V-O ETS 2060

The HGS 3595 electromechanical hygrostat triggers for high humidity or low temperature and has changeover contacts. Designed to
control heaters when a critical relative humidity of 65% is reached.

Reference Relative Minimum Maximum Connections Dimensions


humidity switching switching HxWxD
% range capacity capacity mm
HGS 3595 35~95% 20V AC/DC 250V AC 5(1)A 3 pole 67 x 50 x 38
100mA
Reference Protection Contact Service Colour Weight
type resistance life and casing (kg)
HGS 3595 IP20 <10m Ohm >100,000 cycles Light grey 0.060
plastic
HGS 3595

The EHGS range of electronic hygrostats trigger for high humidity or low temperature and have changeover contacts. Designed to
control heaters when a critical relative humidity is reached. EMC testing is to EN 55014-1-2, EN 61000-3-2 & EN 61000-3-3.
The reaction time is 5 seconds and the adjuster has an inbuilt LED to indicate that the connected device is in operation.

Reference Voltage Max switching Max relay Connections Dimensions


and relative capacity at output HxWxD
humidity 250V/120V AC AC mm
range or 24V DC
EHGS 230.4090 40 to 90% 8A AC 1.6A 5 pole 64.5 x 42 x 38
100W DC 2.5mm sq
EHGS 230.65 65% pre-set 8A AC 1.6A 5 pole 64.5 x 42 x 38
100W DC 2.5mm sq
EHGS 120.4090 40 to 90% 8A AC 1.6A 5 pole 64.5 x 42 x 38
100W DC 2.5mm sq
EHGS 120.65 65% pre-set 8A AC 1.6A 5 pole 64.5 x 42 x 38
100W DC 2.5mm sq
Reference Protection DIN rail Service Colour Weight
type mounting life and casing (kg)
EHGS 230.4090 IP20 Vertical >50,000 Light grey plastic 0.070
cycles UL94 V-O
EHGS 230.65 IP20 Vertical >50,000 Light grey plastic 0.070
cycles UL94 V-O
EHGS 120.4090 IP20 Vertical >50,000 Light grey plastic 0.070
cycles UL94 V-O EHGS series
EHGS 120.65 IP20 Vertical >50,000 Light grey plastic 0.070
cycles UL94 V-O

Page 65
HT ELECTROMECHANICAL HYGROTHERMS, EHGT ELECTRONIC HYGROTHERM
AND DCSM SWITCH MODULES

HT electromechanical hygrotherms with combined hygrostat and thermostat plus


an LED indicator to indicate the hygrostat function. The thermostat function is with
either normally open (NO) or normally closed (NC) contact sets.

EHGT electronic hygrotherms with combined hygrostat and thermostat plus an


LED indicator to indicate the hygrostat function. The thermostat function has relay
operated change over contacts.

DCSM switching module for switching high current DC appliances in either 24V
DC or 48V DC. A separate conventional switch contact is used as a controller for
temperature or humidity regulation in conjunction with the DC switch module.
HTNC 3595.60

HT electromechanical hygrotherms are for both humidity and temperature control. The hygrotherm function has a range of 35~95%
RH and when RH drops below the preset humidity the circuit is closed and the LED illuminates. The thermostat function has a
range of 0 to +60 deg C with either NO or NC contacts (2 types).

Reference Relative Contact Temperature Load in A Connections Dimensions


humidity function range 250V AC/ HxWxD
range deg C DC mm

HTNO3595.60 35%~95% Normally 0 to +60 5(1)A / 30W 5 pole 70 x 63 x 40


open
HTNC3995.60 35%~95% Normally 0 to +60 5(1)A / 30W 5 pole 70 x 63 x 40
closed
Reference Protection Humidity Service Colour Minimum Weight
type control life and casing switching (kg)
HTNO3595.60 IP20 5-10% of >750,000 Light grey 20V AC/DC 0.090
RH setting cycles plastic 100mA
HTNC3995.60 IP20 5-10% of >750,000 Light grey 20V AC/DC 0.090
RH setting cycles plastic 100mA HTNO 3595.60

EHGT electronic hygrotherms are for both humidity and temperature control. The hygrotherm function has a range of 50~90% RH
and when RH drops below the preset humidity the circuit is closed and the LED illuminates. The thermostat function has a range
of 0 to 60 deg C with relay operated change over contacts. There are two versions, either 230V AC or 120V AC.

Reference Operating Relative Contacts Temperature Load in A Dimensions


voltage humidity range 240V AC/ HxWxD
range deg C DC mm

EHGT 230 230V AC 50~90% Change over 0 to +60 6(1)A 77 x 60 x 43


50/60Hz (relay) 100W
EHGT 120 120V AC 50~90% Change over 0 to +60 8(1.6)A 77 x 60 x 43
50/60Hz (relay) 100W
Reference Protection Service Service Colour Connections Weight
type life NC life NO and casing (kg)

EHGT 230 IP20 > 50,000 > 100,000 Light grey 5 pole 0.200
cycles cycles plastic
EHGT 120 IP20 > 50,000 > 100,000 Light grey 5 pole 0.200 EHGT 230
cycles cycles plastic

DCSM DC switch module is used in conjunction with a thermostat, hygrostat or a pressure


regulator for switching DC currents up to 16A. The IP rating is IP20 and the housing
is UL94 V-O light grey plastic.

Reference Operating Maximum Service Contact Connections Dimensions


voltage switching life resistance H x W x D mm
current (kg)
DCSM 24 24V DC 16A DC >100,000 < 10m Ohm 6 pole 67 x 50 x 46: 0.85
20~28V DC cycles

DCSM 48 48V DC 16A DC >100,000 < 10m Ohm 6 pole 67 x 50 x 46: 0.85
38~56V DC cycles
DCSM 24

Page 66
ANTI-CONDENSATION HEATERS FROM 10 WATTS TO 400 WATTS
FOR ENCLOSURES AND CONTROL PANELS

Comprehensive ranges of anti-condensation heaters for a wide


range of applications and enclosure sizes.

NCHW range: PTC resistor, self regulating with wire connections.


With power ratings from 10W~30W.

NCHT range: PTC resistor, self regulating with terminals.


With power ratings of 15W~150W.

FCHT range: PTC resistor, self regulating with wire connections.


With 2 power ratings of 250W and 400W.

Fast and simple installation.


All with mounting for 35mm DIN EN 50022 rail. NCHW 30
Images are not to scale

NCHW series of anti condensation heaters with wire connections with power ratings from
10W~30W. The heater is constructed from anodised extruded aluminium and the heater ele-
ment is a PTC resistor with temperature limiting. Fitting position is with a vertical airflow and
connections at the bottom.

Reference Voltage Heating Protection Connections Size in mm NCHT 100


capacity W x D x H : (kg)
in Watts

NCHW 10 110~250V AC or DC 10 IP44 Class 1 300mm silicon cable 50 x 25 x 52 : 0.10

NCHW 20 110~250V AC or DC 20 IP44 Class 1 300mm silicon cable 50 x 25 x 60 : 0.20

NCHW 30 110~250V AC or DC 30 IP44 Class 1 300mm silicon cable 50 x 25 x 70 : 0.20

NCHT series of anti-condensation heaters with terminal connections with power ratings from
15W~150W. The heater is constructed from anodised extruded aluminium and the heater
element is a PTC resistor with temperature limiting. Fitting position is with a vertical airflow
and connections at the bottom.

Reference Voltage Heating Protection Terminal Size in mm


capacity connections W x D x H: (kg)
in Watts (solid wire)

NCHT 15 120-250V AC or DC 15 IP20 Class I 0.50-2.5mm sq 70 x 60 x 75: 0.30

NCHT 30 120-250V AC or DC 30 IP20 Class I 0.50-2.5mm sq 70 x 60 x 75: 0.30

NCHT 45 120-250V AC or DC 45 IP20 Class I 0.50-2.5mm sq 70 x 60 x 75: 0.30


FCHT 400
NCHT 60 120-250V AC or DC 60 IP20 Class I 0.50-2.5mm sq 70 x 60 x 75: 0.30
NCHT 75 120-250V AC or DC 75 IP20 Class I 0.50-2.5mm sq 70 x 60 x 75: 0.30
NCHT 100 120-250V AC or DC 100 IP20 Class I 0.50-2.5mm sq 70 x 60 x 145: 0.50
NCHT 150 120-250V AC or DC 150 IP20 Class I 0.50-2.5mm sq 70 x 60 x 145: 0.50

FCHT series of fan assisted anti-condensation heaters with terminal connections with power
ratings of 250W and 400W. The heater is constructed from anodised extruded aluminium
and the heater element is a PTC resistor with temperature safety cut out. Maximum surface
temperature is 75 deg C and fitting position is with vertical airflow and connections at the
bottom.

Reference Voltage Heating Protection Connections Size in mm


capacity in W x D x H: (kg)
Watts
FCHT 250 230V 50/60Hz 250W IP20 Class I Terminals 85 x 100 x 182: 1.10
FCHT 400 230V 50/60Hz 400W IP20 Class I Terminals 85 x 100 x 222: 1.40

Page 67
FAN ASSISTED ANTI-CONDENSATION HEATERS FROM 800 WATT TO 1500 WATT
FOR ENCLOSURES AND CONTROL PANELS

A comprehensive range of fan assisted anti-condensation heaters


for a wide variety of applications and enclosure sizes.

MCHT range: PTC resistor heater element.


Four power ratings of 800W, 1000W, 1200W and 1500W.

Supply voltages 110V 50Hz and 230V 50Hz.

For mounting on 35mm DIN rail to EN 50022.


Terminal block connections to V-0 (black).

With fast and simple installation.


IP20 rated and CE marked.

MCHT 1000. 230

MCHT series of fan assisted anti condensation heaters with terminal connections and power ratings of 800W, 1000W, 1200W
and 1500W.
Supplied in either 110V 50Hz or 230V 50HZ versions. The heater is Class I earthed metal work with an extruded aluminium and
anodised outer casing. The heater element is a PTC resistor with a temperature safety fuse in case of fan failure.

The axial fan is ball bearing and has a service life is 50,000 hours at 25 deg C and fitting position is with a vertical airflow and terminal
block connections at the bottom. The terminal block is 2.5mm sq. Air flow rate is 35 cu m/hour free flowing.

Reference Description Voltage (Hz) Heating Airflow Operating and Size in mm


and maximum capacity in Free flow storage L x W x H : (kg)
current Watts temperature

MCHT 800. 110 Fan heater 110V 50Hz 800 35 cu m/hr -25 deg C 168 x 146 x 132
with thermal fuse 8 Amps to 1.5kg
+70 deg C

MCHT 800. 230 Fan heater 230V 50Hz 800 35 cu m/hr -25 deg C 168 x 146 x 132
with thermal fuse 8 Amps to 1.5kg
+70 deg C

MCHT 1000. 110 Fan heater 110V 50Hz 1000 35 cu m/hr -25 deg C 168 x 146 x 132
with thermal fuse 9 Amps to 1.5kg
+70 deg C

MCHT 1000. 230 Fan heater 230V 50Hz 1000 35 cu m/hr -25 deg C 168 x 146 x 132
with thermal fuse 9 Amps to 1.5kg
+70 deg C

MCHT 1200. 110 Fan heater 110V 50Hz 1200 35 cu m/hr -25 deg C 168 x 146 x 132
with thermal fuse 12 Amps to 1.5kg
+70 deg C

MCHT 1200. 230 Fan heater 230V 50Hz 1200 35 cu m/hr -25 deg C 168 x 146 x 132
with thermal fuse 12 Amps to 1.5kg
+70 deg C

MCHT 1500. 110 Fan heater 110V 50Hz 1500 35 cu m/hr -25 deg C 168 x 146 x 132
with thermal fuse 13 Amps to 1.5kg
+70 deg C

MCHT 1500. 230 Fan heater 230V 50Hz 1500 35 cu m/hr -25 deg C 168 x 146 x 132
with thermal fuse 13 Amps to 1.5kg
+70 deg C

Page 68
BLUE SECTION

ETE is a leading UK transformer manufacturer as well as a key national distributor for a comprehensive range of
electrical power products for the controls and automation markets.
Our ranges of transformer and control panel accessories compliment our three main product categories of transformers
and wound components, power electronics and thermal management products.

Contents summary

Transformer and panel


accessories

 Yuasa batteries

 Battery modules & battery holders

 Hinged windows to IP65

 DIN rail sockets & industrial plugs


& sockets

 Panel & enclosure lighting

 Various transformer & panel accessories

 Distribution blocks for 1ph and 3ph

 DIN rail, bus bar insulators & bus bar

 Sheet steel enclosures from IP22 to IP65

 Transformer enclosures for outdoor use

 ….and much more

Page 69 ETE ...........in complete control of power


SUB INDEX

ETE’s transformer and panel accessories completes our comprehensive ranges of electrical power products.
Our technical team is ready to assist in the selection and pricing of your requirements whatever the quantity.
Many products are available ex stock either direct or via our extensive network of UK distributors.

Contents detail

Transformer and panel accessories

Page 71 NP series of Yuasa valve regulated lead acid batteries

Page 72 Additional Yuasa battery ranges for various applications

Page 73 Battery modules, battery holders and battery packs

Page 74 Yu-Power intelligent battery chargers and accessories using micro processor controlled technology

Page 75 IP65 front panel hinged windows with or without back boxes plus DIN rail brackets

Page 76 DIN rail mounted sockets and industrial plugs and sockets to IP44 and IP67

Page 77 Panel and enclosure lighting (fluorescent from 4 watts to 21 watts) and lead extensions for lighting

Page 78 Panel and enclosure lighting (LED series from 7 watts to 10 watts) and 5 watt magnetic unit

Page 79 DB series of distribution blocks in 1ph and 3ph

Page 80 UK series of 2 and 4 pole distribution blocks

Page 81 DIN rail and DIN rail brackets, DIN rail cut and punch service and engraving service

Page 82 Bus bar insulators and copper bus bar either plain or cut to length and fabricated

Page 83 Transformer accessories and control panel accessories

Page 84 Sheet steel enclosures from IP22 to IP65

Page 85 Sheet steel enclosures from IP23 to IP55

Page 86 Transformer enclosures for outdoor use to IP55

Page 70 ETE ...........in complete control of power


NP SERIES OF YUASA VALVE REGULATED LEAD ACID BATTERIES

Maintenance free rechargeable batteries.


In 6V from 1Ah to 12Ah & 12V from 0.8Ah to 65Ah.

Superb recovery from deep discharge.


No fear of electrolyte leakage regardless of orientation.
Multipurpose float or cyclic use.
Superior energy density.
Lead calcium grids for extended life.
Control of gas generation using oxygen recombination
technology.

APPLICATIONS INCLUDE:
Control systems, standby power systems, emergency lighting, alarm systems, UPS control and medical equipment.

The NP series of valve regulated lead acid batteries cover a wide range of sizes to suit general applications.
Their unique sealed construction ensures no electrolyte leakage from either the case or the terminals.
Dependant on the average depth of discharge, over one thousand discharge/charge cycles can be expected. The
expected life is five years in float standby mode. The extremely low self discharge rate allows the batteries to be stored
for up to one year at normal ambient temperatures without any permanent loss of capacity.

Operating temperature range;


Charge -15 to +50 deg C, Discharge –20 to +60 deg C and Storage –20 to +50 deg C (fully charged battery).

Reference Nominal Nominal capacity Length Width Height O/A Weight Terminals
voltage (20H.R.) (Ah) mm mm mm (kg)
(V)
NP 1-6 6 1.0 51 42.5 54.5 0.25 Faston tab 187

NP 1.2-6 6 1.2 97 25 54.5 0.31 Faston tab 187

NP 2.8-6 6 2.8 134 34 64 0.57 Faston tab 187

NP 4-6 6 4.0 70 47 105.5 0.87 Faston tab 187

NP 7-6 6 7.0 151 34 97.5 1.32 Faston tab 187

NP 10-6 6 10.0 151 50 97.5 1.93 Faston tab 187/250

NP 12-6 6 12.0 151 50 97.5 2.05 Faston 250

NP 0.8-12 12 0.8 96 25 61.5 0.35 VHR-2N

NP 1.2-12 12 1.2 97 48 54.5 0.58 Faston tab 187

NP 2-12 12 2.0 150 20 89/85 0.70 Faston tab 187

NP 2.1-12 12 2.1 178 34 64 0.82 Faston tab 187

NP 2.3-12 12 2.3 178 34 64 0.95 Faston tab 187

NP 2.8-12 12 2.8 134 67 64 1.12 Faston tab 187

NP 3.2-12 12 3.2 134 67 64 1.20 Faston tab 187

NP 4-12 12 4.0 90 70 106 1.75 Faston tab 187/250

NP 7-12 12 7.0 151 65 97.5 2.65 Faston tab 187/250

NP12-12 12 12.0 161 98 97.5 4.05 Faston 250

NP 17-12 I 12 17.0 181 76 167 6.10 M5 screw

NP 18-12 12 18.0 180 76 167 6.20 M5 bolt and nut

NP 24-12 I 12 24.0 166 175 125 9.00 M5 screw

NP 38-12 I 12 38.0 197 165 170 14.2 M5 screw

NP 65-12 I 12 65.0 350 166 174 23.00 M6 screw

Page 3
Page 71
ADDITIONAL YUASA BATTERY RANGES FOR VARIOUS APPLICATIONS

Valve regulated lead acid batteries


NPC series, NPL series, EN series, ENL series.
SWL series, TEV series.
ENL-FT front terminal type.
REC 10-12.
UXF, UFH and UXL series.
Y series.
Other types
NiCd series of cylindrical nickel cadmium batter-
ies.
NiMh series of cylindrical metal hydride batteries.

APPLICATIONS INCLUDE:
UPS and back up power, standby power systems, emergency lighting, alarm systems and medical equipment.

Yuasa are one of the world’s largest manufacturers and suppliers of valve regulated lead acid batteries with global
manufacturing plants and an extensive marketing and distribution network throughout the UK and Europe.

The Yuasa ranges provide one of the widest choices of types from a single source.

A comprehensive range of battery types for a wide variety of applications.


For detailed technical specifications go to www.yuasa-battery.co.uk or contact our sales department.

Series Voltage / Ah Applications

NPC series 12V Wheelchairs, golf trolleys, lawn mowers, lights, toy cars, sprayers,
17Ah, 24Ah, 30Ah, 38Ah and 65Ah (20 hr rate) photovoltaics, robots, communications, electric tools, pumps, measuring
instruments, automatic guided vehicles, magnetic lifts
NPL series 6 V 130Ah & 200 Ah Security and fire, UPS, telecoms and emergency lighting
12V 24Ah, 38Ah, 65Ah, 78Ah
and 100Ah (20 hr rate)
EN series 4V 80Ah,100Ah & 140Ah (10 hr to 1.85vpc) Standby applications including telecommunications, UPS,
6V 80Ah, 100Ah & 160Ah (10 hr to 1.85vpc) emergency lighting

ENL series 2V 320Ah & 480Ah (10 hr to 1.85vpc) Standby applications including telecommunications, UPS,
4V 160Ah, 6V 100Ah & 160Ah (10 hr to 1.85vpc) emergency lighting

SWL series 6V and 12V high capacity High power and high discharge capacity

TEV series 12V High capacity Wheelchairs, golf trolleys, lawn mowers, lights, toy cars, sprayers,
photovoltaics, robots, communications, electric tools, pumps, measuring
instruments, automatic guided vehicles, magnetic lifts
ENL-FT 12V 100Ah (10 hr to 1.80vpc) Standby applications including telecommunications, UPS,
front terminal emergency lighting

REC 10-12 12V 10Ah (20 hr rate) General use

UXF, UXH & 2V, 6V and 12V For high density applications and 48V 19in and 23in rack systems
UXL series

Y series 2V, 4V, 6V, 12V Standby applications including alarms, emergency lighting & general use

NiCd Cylindrical Nickel Cadmium General use: high capacity, miniature

NiMH Cylindrical Metal Halide General use: high capacity, miniature

Page 72
BATTERY MODULES
BATTERY HOLDERS AND BATTERY PACKS

Battery modules for use with ‘all-in-one’ and standard battery


chargers.

Four hole fixing via M4 screws.


Protection to IP20.
Short circuit protected via 25A fuse.

Battery holders and replacement batteries.

A range of battery modules from 12V 3.2Ah to 24V 12Ah for use in conjunction with all in one chargers and standard battery chargers.
Mounting is direct to a panel back plate via 4 x M4 screws. All units are fully short circuit protected with a 25A fuse. The operational
ambient temperature range is +5 to +40 deg C. Storage temperature is -20 to +50 deg C. The protection class is IP20.
Also separate battery holders and replacement batteries.

Battery modules

Battery module DC Output End of charge Trickle Maximum Self discharge Dimensions Weight
reference DC voltage charge charging rate mm (kg)
DC V current LxWxH
BM12:3.2 12V 3.2Ah 13.7V (20 deg C) 13.5V DC (30 deg C) 0.30A 20 deg C 105 x 85 x 135 1.50
13.25V DC (40 deg C) 15% per month
BM12:7 12V 7.0Ah 13.7V (20 deg C) 13.5V DC (30 deg C) 0.80A 20 deg C 105 x 120 x 180 2.60
13.25V DC (40 deg C) 15% per month
BM12:9 12V 9.1Ah 13.7V (20 deg C) 13.5V DC (30 deg C) 1.0A 20 deg C 105 x 120 x 180 2.60
13.25V DC (40 deg C) 15% per month
BM24:1.2 24V 1.2Ah 27.5V (20 deg C) 27V DC (30 deg C) 0.30A 20 deg C 170 x 75 x 100 1.60
26.5V DC (40 deg C) 15% per month
BM24:3.2 24V 3.2Ah 27.5V (20 deg C) 27V DC (30 deg C) 0.80A 20 deg C 170 x 85 x 140 3.10
26.5V DC (40 deg C) 15% per month
BM24:7 24V 7.0Ah 27.5V (20 deg C) 27V DC (30 deg C) 1.7A 20 deg C 170 x 120 x 150 5.20
26.5V DC (40 deg C) 15% per month
BM24:12 24V 12Ah 27.5V (20 deg C) 27V DC (30 deg C) 2.8A 20 deg C 230 x 120 x 150 7.60
26.5V DC (40 deg C) 15% per month

Battery module buffering times


Battery module Buffering time (min) Buffering time (min) Buffering time (min) Buffering time (min) Buffering time
reference Load 1.5A Load 3.0A Load 5.0A Load 7.0A (min)
Load 10A

BM12:3.2 120 60 30 20 10
BM12:7 250 120 80 50 30
BM12:9 360 150 100 70 None
BM24:1.2 40 20 15 25 None
BM24:3.2 120 60 30 20 10

BM24:7 250 120 80 50 30

BM24:12 400 200 140 100 60

Battery holders and replacement batteries


Battery holder Description Yuasa NP or Y series Description
reference battery reference(s)
BH 12:3.2 Battery holder only for battery 12V 3.2Ah NP 3.2-12 1 x 12V 3.2Ah
BH 12:7 Battery holder only for battery 12V 7.0Ah NP 7-12 1 x 12V 7.0Ah
BH 12:9 Battery holder only for battery 12V 9.0Ah Y 9-12 1 x 12V 9.0Ah
BH 24:1.2 Battery holder only for battery 24V 1.2Ah 2 x NP 1.2-12 2 x 12V 1.2Ah for 24V
BH 24:3.2 Battery holder only for battery 24V 3.2Ah 2 x NP 3.2-12 2 x 12V 3.2Ah for 24V
BH 24:7 Battery holder only for battery 24V 7.0Ah 2 x NP 7-12 2 x 12V 7.0Ah for 24V
BH 24:12 Battery holder only for battery 24V 12Ah 2 x NP 12-12 2 x 12V 12Ah for 24V

Page 73
YU-POWER INTELLIGENT BATTERY CHARGERS AND ACCESSORIES
USING MICRO PROCESSOR CONTROLLED TECHNOLOGY

Intelligent battery chargers using multi-stage


proportional timing technology.
Ambient temperature range 0 to +40 deg C.
Humidity 90% non condensing.

For indoor use only.


For use with lead acid batteries only.
Ready for connection to UK mains sockets.

These chargers utilise multi-stage proportional timing technology to ensure safe and efficient charging of lead acid batteries. The
use of this technology ensures the best balance of maximum state of charge, without damaging the battery before switching to float
charging mode. Once in float charge mode the charger will charge whilst using an ECO mode to save power. The intelligence of
these chargers is further demonstrated by employing a combination of cut off systems, which prevents over charging of the battery.
Within the Yu-Power range there are charger types suitable for VRLA, car and motorcycle batteries.

A range of special fixing brackets for DIN rail or chassis mounting is available for all types.

Charger Input V Output V Output V Output Dimensions in mm Input Output Battery For battery
reference at 50HZ DC DC current L x W x H : kg connector connector charging chemistry
absorption float A capacity

YPC09A 230V 14.4V 13.3~13.6V 0.9A 95.5 x 66 x 87.5 : 0.51 UK 1.2m Up to 20Ah All lead acid
12MC Plug top Power lead MC types
Vehicle
trailer/clips
YPC2A6 220~260V 7.2V 6.83V 2.0A 140 x 65 x 42 : 0.45 1.8m 1.2m 6 to 20Ah All lead acid
Power lead Power lead types
UK plug Vehicle
trailer/clips
YPC2A12 220~260V 14.4V 13.65V 2.0A 140 x 65 x 42 : 0.45 1.8m 1.2m 6 to 20Ah All lead acid
Power lead Power lead types
UK plug Vehicle
trailer/clips
YPC4A12 220~260V 14.4V 13.65V 4.0A 164 x 85 x 55 : 0.62 1.8m 1.2m 12 to 40Ah All lead acid
Power lead Power lead types
UK plug YPCCLIP

YPC8A12 220~260V 14.4V 13.65V 8.0A 190 x 92 x 55 : 0.86 1.8m 1.2m 30 to 100Ah All lead acid
Power lead Power lead types
UK plug YPCCLIP

YPC4A24 220~260V 28.8V 27.3V 4.0A 190 x 92 x 55 : 0.86 1.8m 1.2m 12 to 40Ah All lead acid
Power lead Power lead types
UK plug YPCCLIP

12 Volt battery checker

Reference Input voltage Dimensions in mm Input Input Suitable battery For battery
L x W x H : (kg) connector adaptors capacity range chemistry

YPCTESTMC 3V to 14V AC 46 x 20 x 13: 0.01 Vehicle Vehicle trailer Any 12V Ah All lead acid
trailer to clips MC types

Accessories

Reference Accessory type Supplied with charger type

YPCCLIP Torbury to clips adaptor YPC4A12, YPC8A12, YPC4A24

YPCCLIPMC Motorcycle plug to clips adaptor YPC09A 12MC, YPC2A6, YPC2A12,

YPCPK Torbury to Powakaddy adaptor YPC4A12, YPC8A12, YPC4A24

YPCRINGMC Motorcycle plug to ring connectors with fuse

Page 74
IP65 FRONT PANEL HINGED WINDOWS
WITH OR WITHOUT BACK BOXES PLUS DIN RAIL BRACKETS

A comprehensive range of high quality hinged windows.


With or without back boxes.
For front panel mounting of MCBs, fuse modules and DIN rail components.

In 4 module, 6 module, 8 module and 12 module options.

Plus full range of DIN rail brackets for easy mounting of components.

A complete range of front panel mounted hinged windows for mounting MCB, fuse and DIN rail mounted modules. With and without
back boxes. Back box mounting offers a high quality assembly and wiring finish.
Protection is to IP65, with high impact moulded transparent cover and supplied with optional DIN rail brackets for component
mounting if required.

Reference Description No of MCB No of locking Cut out size Overall size


modules screws and fixings in mm in mm

APEK 90042 4 way hinged window with back box 4 2 77 L x 64 H : 4 holes 91 L x 98 H

APEK90062 6 way hinged window with back box 6 2 112 L x 64 H: 6 holes 122 L x 98 H

APEK 90082 8 way hinged window with back box 8 2 147 L x 64 H: 6 holes 163 L x 98 H

APEK 90122 12 way hinged window with back box 12 3 220L x 64 H: 6 holes 234 L x 98 H

APEK 90023 2 way hinged window without back box 2 2 39 L x 64H: 4 holes 60 L x 98 H

APEK 90043 4 way hinged window without back box 4 2 77 L x 64 H: 4 holes 91 L x 98 H

APEK 90063 6 way hinged window without back box 6 2 112 L x 64 H: 6 holes 122 L x 98 H

APEK 90083 8 way hinged window without back box 8 2 147 L x 64 H: 6 holes 163 L x 98 H

APEK 90123 12 way hinged window without back box 12 3 220L x 64 H: 6 holes 234 L x 98 H

APEK 2DIN 2 module bracket with DIN rail 2 n/a n/a Fits 2 module unit

APEK 4DIN 4 module bracket with DIN rail 4 n/a n/a Fits 4 module unit

APEK6DIN 6 module bracket with DIN rail 6 n/a n/a Fits 6 module unit

APEK8DIN 8 module bracket with DIN rail 8 n/a n/a Fits 8 module unit

APEK12DIN 12 module bracket with DIN rail 12 n/a n/a Fits 12 module unit

Page 75
DIN RAIL MOUNTED SOCKETS
AND INDUSTRIAL PLUGS AND SOCKETS TO IP44 AND IP67

A comprehensive range of high quality DIN rail mounted sockets to various


national standards.

A comprehensive range of high quality industrial plugs and sockets to


BS EN 60309-1 (BS 4343).
In 110V, 230~240V and 400~420V AC from 16A to 32A.
Protection to IP44 and IP67.

A range of DIN rail mounted sockets for power tools, instruments and for output
supplies from control panels. MARL 1412.UK

Reference Voltage & Standard Connections Protection Dimensions


current L x W x H mm: (kg)

MARL1412.UK 250V 16A UK 3 pole Class I, 53 x 82 x 60:0.10


2.5mm sq IP20
MARL1412.I 250V 16A Schuko 3 pole Class I, 53 x 82 x 60:0.10
2.5mm sq IP20
MARL1412.F 250V 16A France 3 pole Class I, 53 x 82 x 60:0.10
2.5mm sq IP20
ALFA SOCKET01 250V 16A Germany 3 pole Class I, 92 x 57 x 51:0.10
2.5mm sq IP20
ALFA SOCKET02 250V 16A Italy 3 pole Class I, 92 x 57 x 51:0.10
2.5mm sq IP20
ALFA SOCKET03 250V 16A France 3 pole Class I, 92 x 57 x 51:0.10
2.5mm sq IP20
ALFA SOCKET04 125V 16A Euro- 3 pole Class I, 92 x 57 x 51:0.10
American 2.5mm sq IP20 Industrial plugs and sockets to
ALFA SOCKET05 250V 16A Spain 3 pole Class I, 92 x 57 x 51:0.10 IP44 and IP67
2.5mm sq IP20

Comprehensive range of BS EN 60309-1 (BS4343) IP44 and IP67 plugs and sockets in 110V, 230~240V and 400~420V in both
16A and 32A versions.

Reference Description of socket IP Rating Size Reference Description of plug IP Rating Size
for angled and colour in mm for suitable plug and colour in mm
panel socket coding coding

PS44.110.16.2PE 110V 16A 2P + E IP44 64 x 74 PP44.110.16.2PE 110V 16A 2P + E IP44 130 L O/A
PS44.230.16.2PE 230V 16A 2P + E IP44 64 x 74 PP44.230.16.2PE 230V 16A 2P + E IP44 130 L O/A

PS44.400.16.3PE 400V 16A 3P + E IP44 70 x 85 PP44.400.16.3PE 400V 16A 3P + E IP44 130 L O/A

PS44.400.16.3PNE 400V 16A 3P + N + E IP44 80 x 97 PP44.400.16.3PNE 400V 16A 3P + N + E IP44 130 L O/A
PS44.110.32.2PE 110V 32A 2P + E IP44 92 x 100 PP44.110.32.2PE 110V 32A 2P + E IP44 160 L O/A

PS44.230.32.2PE 230V 32A 2P + E IP44 92 x 100 PP44.230.32.2PE 230V 32A 2P + E IP44 160 L O/A

PS44.400.32.3PE 400V 32A 3P + E IP44 92 x 100 PP44.400.32.3PE 400V 32A 3P + E IP44 160 L O/A

PS44.400.32.3PNE 400V 32A 3P + N + E IP44 92 x 100 PP44.400.32.3PNE 400V 32A 3P + N + E IP44 160 L O/A

PS67.110.16.2PE 110V 16A 2P + E IP67 92 x 100 PP67.110.16.2PE 110V 16A 2P + E IP67 130 L O/A

PS67.230.16.2PE 230V 16A 2P + E IP67 92 x 100 PP67.230.16.2PE 230V 16A 2P + E IP67 130 L O/A

PS67.400.16.3PE 400V 16A 3P + E IP67 92 x 100 PP67.400.16.3PE 400V 16A 3P + E IP67 130 L O/A

PS67.400.16.3PNE 400V 16A 3P + N + E IP67 92 x 100 PP67.400.16.3PNE 400V 16A 3P + N + E IP67 130 L O/A

PS67.110.32.2PE 110V 32A 2P + E IP67 92 x 100 PP67.110.32.2PE 110V 32A 2P + E IP67 160 L O/A

PS67.230.32.2PE 230V 32A 2P + E IP67 92 x 100 PP67.230.32.2PE 230V 32A 2P + E IP67 160 L O/A

PS67.400.32.3PE 400V 32A 3P + E IP67 92 x 100 PP67.400.32.3PE 400V 32A 3P + E IP67 160 L O/A

PS67.400.32.3PNE 400V 32A 3P + N + E IP67 92 x 100 PP67.400.32.3PNE 400V 32A 3P + N + E IP67 160 L O/A

Page 76
PANEL AND ENCLOSURE LIGHTING
FLUORESCENT SERIES FROM 4 WATTS TO 21 WATTS AND EXTENSION LEADS

Fluorescent series from 4 Watts to 21 Watts.


In lengths from 156mm to 871mm.

High brightness and compact design with on/off switch.


Voltage range 110~130V AC or 220~240V AC.
With opal cover as standard, striate cover also available
for volume orders.
Long life, non-flicker.

2 metre extensions for both fluorescent


and LED lighting are available.

A comprehensive range of fluorescent lighting for a wide range of panel and enclosure lighting applications.
The LK-Y5D series are fluorescent lamps with high light output with low power consumption. They are compact and easy
to install, with some units suitable for multiple chain connection.
The standard cover colour is opal with striate cover colour available on request .

Two types suitable for connection to a 110~130V 50Hz or 220~240V 50Hz supply voltage.
LK-Y5 fluorescent series

Reference Power Voltage and Hz Power factor IP rating Colour temperature Dimensions
rating PF L x W x H mm
LK-Y5D04 110 A* 4W 100~130V 50Hz 0.55 IP20 2700/6500K 156 x 24 x 40

LK-Y5D04 240 A* 4W 220~240V 50Hz 0.55 IP20 2700/6500K 156 x 24 x 40

LK-Y5D06 110 A* 6W 100~130V 50Hz 0.55 IP20 2700/6500K 255 x 24 x 40

LK-Y5D06 240 A* 6W 220~240V 50Hz 0.55 IP20 2700/6500K 255 x 24 x 40


LK-Y5D08 110 A* 8W 100~130V 50Hz 0.55 IP20 2700/6500K 309 x 24 x 40
LK-Y5D08 240 A* 8W 220~240V 50Hz 0.55 IP20 2700/6500K 309 x 24 x 40
LK-Y5D12 110 A* 12W 100~130V 50Hz 0.55 IP20 2700/6500K 486 x 24 x 40
LK-Y5D12 240 A* 12W 220~240V 50Hz 0.55 IP20 2700/6500K 486 x 24 x 40
LK-Y5D14 110 A* 14W 100~130V 50Hz 0.55 IP20 2700/6500K 571 x 24 x 40
LK-Y5D14 240 A* 14W 220~240V 50Hz 0.55 IP20 2700/6500K 571 x 24 x 40
LK-Y5D18 110 A* 18W 100~130V 50Hz 0.95 IP20 2700/6500K 731 x 24 x 40
LK-Y5D18 240 A* 18W 220~240V 50Hz 0.95 IP20 2700/6500K 731 x 24 x 40
LK-Y5D21 110 A* 21W 100~130V 50Hz 0.95 IP20 2700/6500K 871 x 24 x 40
LK-Y5D21 240 A* 21W 220~240V 50Hz 0.95 IP20 2700/6500K 871 x 24 x 40

* Suffix A is for standard opal colour, suffix B is for striate colour (also available for volume orders).

Two types of lead extensions for both fluorescent and LED lighting units.
Both are 2 metres long, extending the connection of the fluorescent lamps from 150mm and the LED lamps
from 200mm.

Reference Power rating

LK-FLR 02 2m connection for fluorescent lamps including cable


and plug
LK-LED 02 2m connection for LED lamps including cable
and plug

Page 77
PANEL AND ENCLOSURE LIGHTING
LED SERIES FROM 4 WATTS TO 10 WATTS AND 5 WATT MAGNETIC LED LIGHTING

LED series from 7 Watts to 14 Watts.

No strobe effect, no infra-red & UV.


Voltage range 110~240V AC.
With opal cover.
Typical life >50,000 hours.

LK-025 magnetic series.


5 Watt rating.

A comprehensive range of LED lighting for a wide range of panel and enclosure lighting applications.
The LK-L5X series are LED lamps with high quality LED chips as the light source.
There is no strobe effect, no infra-red and UV and the light output is radiation free. The LED chips are cold light type,
impact resistant and shockproof. The units are easy to install and are interlockable to extend their length .

They have an excellent operational lifespan with typical life of 50,000 hours.
LK-L5X LED series

Reference Power Voltage and Hz LED (pcs) IP rating Light output Dimensions
rating (in lm) Length in mm

LK-L5X4A* 4W 110~240V 50/60Hz 38 IP20 3000/6400 lm 309

LK-L5X5A* 5W 110~240V 50/60Hz 52 IP20 3000/6400 lm 486

LK-L5X6A* 6W 110~240V 50/60Hz 60 IP20 3000/6400 lm 571

LK-L5X9A* 9W 110~240V 50/60Hz 80 IP20 3000/6400 lm 731

LK-L5X10A* 10W 110~240V 50/60Hz 102 IP20 3000/6400 lm 871

* Suffix A is for standard opal colour, suffix B is for striate colour (also available for volume orders).

Two types of LED panel lamps with non-slip rubberised


magnets for moving within steel enclosures or with
standard screw fixing. Available in AC and DC versions.
Multiple lamps can be connected together.
Very long service life of 60,000 hours at 20 deg C.
Power rating 5 Watts, with on/off switch.
Casing is robust transparent plastic

LK-025 LED series

Reference Fixing Voltage and Hz or DC Ambient IP rating Light output Dimensions


temperature & Class (in Lm) L + magnet/screw centres
LK-025 AC M Magnets 90~265V AC 50/60Hz -30 to +60 IP20 290 lm 351 x 250mm
deg C Class II
LK-025 DC M Magnets 20~60V DC -30 to +60 IP20 290 lm 351 x 250mm
deg C Class II
LK-025 AC F Screw 90~265V AC 50/60Hz -30 to +60 IP20 290 lm 351 x 250mm
deg C Class II
LK-025 DC F Screw 20~60V DC -30 to +60 IP20 290 lm 351 x 250mm
deg C Class II

Page 78
DB SERIES OF DISTRIBUTION BLOCKS
FROM 80 AMPS TO 400 AMPS 1PH AND 125AMPS TO 175 AMPS 3PH

Wide range of single pole units from 80~400 Amps.


Three phase units in 125A &175A.

DIN rail or chassis mounted with screws.


IP20 rated with hinged and removable cover.
High conductivity with excellent electrical contacts.
Compact design.
Modular design for other 3ph modules.
CE marked and RoHS compliant.

Ex stock availability with competitive pricing.

A comprehensive range of single pole distribution blocks for DIN rail mounting or chassis mounting from
80~400 Amps. There are also two 3ph options in 125A and 175A.
DB 80A, DB 125A and DB 175A units can be parallel connected using jumper cables.
The UL flammability class is UL 94 V-0, the rated impulse voltage is 2.5kV and the pollution grade is Grade 3.
The voltage rating is up to 690V. The peak short circuit current ratings are DB 80A-22kA, DB 125A~175A-30kA
and DB 250A~DB 400A-51kA.
The output connection listed include stranded and solid cable, flexible bus bar and flexible cable with wire ended
ferrules to DIN 46228-1.
All units have high quality connections for good conductivity.

Stripping lengths for input connections are M5/M6: 9~12mm, M8: 14~15mm, M10:15~16mm M12/M16: 27-29mm.
Stripping lengths for output connections are DB 80A: 9~12mm and all other sizes 10~12mm.

For full Nm and torque settings for installation please contact our sales department.

Reference Description Current 1 pole input Output Input hole size Dimensions
rating in cable CSA connections and diameter in mm
Amps stranded or solid Output hole sizes LxWxH
& maximum and flexible and diameters
voltage bus bar
DB 80A 80A 1 pole input 80A 690V 1 x 2.5~16mm sq 6.8mm M6 66 x 30.2 x 48
4 x 2.5~6mm sq 4.5mm M5
2 x 2.5~16mm sq 6.8mm M6
DB 125A 125A 1 pole input 125A 690V 1 x 10~35mm sq 10mm M8 75 x 40 x 50
1 x 6~16mm sq 6.8mm M6
8 x 2.5~16mm sq 6.8mm M6

DB 175A 160A 1 pole input 175A 690V 1 x 16~70mm sq 12mm M10 75 x 40 x 50


1 x 6~16mm sq 6.8mm M6
8 x 2.5~16mm sq 6.8mm M6
DB 250A 250A 1 pole input 250A 690V 1 x 35~120mm sq 15mm M12 96 x 46.8 x 51.5
2 x 2.5~35mm sq 9mm M10
5 x 2.5~16mm 6.8mm M6
4 x 2.5~10mm sq 6.1mm M5
DB 400A 400A 1 pole input 400A 690V 1 x 95~185mm sq 19mm M16 96 x 46.8 x 51.5
2 x 2.5~35mm sq 9mm M10
5 x 2.5~16mm 6.8mm M6
4 x 2.5~10mm sq 6.1mm M5

DB 3P 125A 125A 3 pole input 125A 690V 3 x 10~35mm sq 10mm M8 75.5 x 85 x 50


18 x 2.5~16mm sq 6.1mm M6

DB 3P 175A 175A 3 pole input 175A 690V 3 x 16~70mm sq 12mm M10 75.5 x 85 x 50
18 x 2.5~16mm sq 6.1mm M6

Page 79
UK SERIES OF 2 AND 4 POLE DISTRIBUTION BLOCKS
AT 500V 100 AMPS AND 500V 160AMPS

Wide range of 2 pole and 4 pole distribution blocks.

DIN rail or chassis mounted with screws.


To EN 60947-1 and CE compliant.
With main removable cover and removable phase covers.
High conductivity with excellent electrical contacts.
Compact design.
UK 207, UK 407, UK 411 and UK 415 500V 100A
UK 412 500V 160A.

Ex stock availability with competitive pricing .

A comprehensive range of 2 pole and 4 distribution blocks for DIN rail mounting or chassis mounting with ratings of
500V 100A on units UK 207, UK 407, UK 411 and UK 415. The unit UK 412 is rated at 500V 160A.
The maximum rated short circuit current for all types is 20kA.

They are all fitted with clear protective screens between each of the phases and at the base of the distribution block.

A transparent cover is fitted over the terminations and this can be removed for access to the terminals for screw
tightening.
All terminal strips are brass with excellent electrical contacts.

The ambient temperature range is –20 deg C to +40 deg C.

All units are suitable for mounting on 35mm x 7.5mm DIN rail and 35mm x 15mm DIN rail.

Reference No of Current rating Input Cable size Output Cable size Dimensions
poles to cable Input cable input in mm
& cable IEC 60947-1 size Solid or multi-core sizes Solid or multi-core LxHxD
entries & V max to IEC cable cable
per pole

UK 207 2 pole 500V 100A 1 x 16mm sq 6mm sq~16mm sq 1.5mm sq~6mm sq 94 x 50 x44
1 x 25mm sq 10mm sq~25mm sq
7 way 5 x 6mm sq

UK 407 4 pole 500V 100A 3 x 16mm sq 6mm sq~16mm sq 1.5mm sq~6mm sq 109 x 50 x 85
1 x 25mm sq 10mm sq~25mm sq
7 way 5 x 6mm sq

UK 411 4 pole 500V 100A 3 x 16mm sq 6mm sq~16mm sq 1.5mm sq~6mm sq 147 x 50 x 85
1 x 25mm sq 10mm sq~25mm sq
11 way 7 x 6mm sq

UK 415 4 pole 500V 100A 3 x 16mm sq 6mm sq~16mm sq 1.5mm sq~6mm sq 182 x 50 x 85
1 x 25mm sq 10mm sq~25mm sq
15 way 11 x 6mm sq

UK 412 4 pole 500V 160A 3 x 25mm sq 10mm sq~25mm sq 2.5mm sq~16mm sq 170 x 90 x 70
1 x 50mm sq 10mm sq~50mmsq
12 way 8 x 16mm sq

Page 80
EX STOCK RANGE OF DIN RAIL AND ANGLED DIN RAIL SUPPORT BRACKETS
ENGRAVING SERVICE FOR NAMEPLATES AND TERMINAL BOARDS

Full range of DIN rail either plain or slotted.


To EN 50 022, EN 50 035 and EN 50 045.
Zinc plated with centre line for ease of drilling.

Supplied in 1m or 2m lengths.

Can be cut and punched to customer requirements.

A range of DIN rail available from stock in six types.


All steel DIN rails are bright zinc plated with aluminium rail also available.
Supplied in lengths of 1m and 2m with minimum order quantities of 10 pcs per type

Reference Plain or Description EN standard Material and finish Material


slotted thickness

TS 15-5.5 Plain 15mm W x 5.5mm H EN 50 045 Steel with bright zinc plating 1mm

TS 15-5.5 SL Slotted 15mm W x 5.5mm H EN 50 045 Steel with bright zinc plating 1mm

TS 35-7.5 Plain 35mm W x 7.5mm H EN 50 022 Steel with bright zinc plating 1mm

TS 35-7.5 SL Slotted 35mm W x 7.5mm H EN 50 022 Steel with bright zinc plating 1mm

TS 35-15 Plain 35mm W x 15mm H EN 50 022 Steel with bright zinc plating 1.5mm

TS 35-15 SL Slotted 35mm W x 15mm H EN 50 022 Steel with bright zinc plating 1.5mm

TS 32 Plain G rail 32mm x 15mm H EN 50 035 Steel with bright zinc plating 1.5mm

TS 32 SL Slotted G rail 32mm x 15mm H EN 50 035 Steel with bright zinc plating 1.5mm

AL 35-7.5 SL Slotted 35mm W x 7.5mm H EN 50 022 Aluminium 1.1mm

AL 35-15 SL Slotted 35mm W x 15mm H EN 50 022 Aluminium 1.5mm

Cut and punch service:

We can cut and punch the TS 15-5.5, TS 35-7.5 and TS 35-15 standard
DIN rails to customer own requirements up to 1m
lengths in both plain or slotted in steel and aluminium.
Angled support bracket for DIN rail

Part number TSTW


Support bracket for DIN rail, accepts all types
Material thickness 2mm available from stock

Engraving service for nameplates and terminal boards.

Dependant on size, quantities and complexity we can engrave name


plates or terminal boards to customer requirements.

Materials for normal nameplates include aluminium and traffolyte.

Materials for terminal boards include SRBP and Class F polyester


board.

Contact our sales for more details.

Page 81
BUS BAR INSULATORS
AND COPPER BUS BAR EITHER PLAIN OR CUT TO LENGTH AND FABRICATED

Full range of high quality bus bar insulators.

From 6mm to 10mm screw fixing.


Voltage withstand from 6kV to 25kV.

Heights from 25mm to 76mm.


With high tensile strength and torque strength.

A full range of high quality bus bar insulators available from stock.
Screw sizes are from M6 to M10 with voltage withstand from 6kV to 25kV.
Supplied in boxes of 10 pcs.

Reference Screw size Voltage Tensile strength Torque strength Dimensions


diam x L withstand OD x ID x H : Weight in g
SM 25 M6 x 9mm 6kV 500 lbs 6 lbs 27 x 23 x 25mm : 28 g
SM 30 M8 x 10mm 8kV 550 lbs 8 lbs 32 x 26 x 30mm : 44 g
SM 35 M8 x 10mm 10kV 800 lbs 10 lbs 32 x 28 x 35mm: 50 g
SM 40 M8 x 12mm 12kV 650 lbs 10 lbs 40 x 34 x 40mm : 86 g
SM 45 M10 x 13mm 15kV 1000 lbs 20 lbs 37 x 29 x 45mm : 70 g
SM 51 M8 x 12mm 15V 1000 lbs 20 lbs 36 x 29 x 51mm : 83 g
SM 60 M10 x 22mm 25kV 1500 lbs 40 lbs 44 x 32.5 x 60mm : 170 g
SM 76 M10 x 12mm 25kV 1500 lbs 40 lbs 50 x 36 x 76mm : 233 g

High conductivity copper bus bar to BS EN 13601


Variety of standard sizes in stock in 1m lengths

Can be cut to size and punched and fabricated


to customer requirements
Other non standard sizes available

High conductivity copper bus bar with 12 sizes available from stock in 1m lengths.
All types have a radius edge and are burr free.

Special bus bars can be cut to length and fabricated from the standard sizes or from non-stock special sizes. These can
be punched with holes and slots and folded to drawing. Prices available on request.

Standard bus bar sizes available from stock

Reference CSA in sq mm Size Size Current rating at


metric mm Imperial inches 3000A/ sq inch or 4.65A/ sq mm
CBB 50 50.4 15.875 x 3.175 5/8 x 1/8 200 Amps
CBB 60 60.5 19.05 x 3.175 3/4 x 1/8 275 Amps
CBB 80 80.6 25.4 x 3.175 1 x 1/8 350 Amps
CBB100 100.8 31.75 x 3.175 1 1/4 x 1/8 450 Amps
CBB 120 120.0 20 x 6 n/a 550 Amps
CBB 150 150.0 25 x 6 n/a 650 Amps
CBB 180 180.0 30 x 6 n/a 800 Amps
CBB 240 240.0 40 x 6 n/a 1000 Amps
CBB 300 300.0 50 x 6 n/a 1300 Amps
CBB 360 360.0 60 x 6 n/a 1500 Amps
CBB 450 450.0 75 x 6 n/a 2000 Amps
CBB 600 600.0 100 x 6 n/a 2750 Amps

Page 82
TRANSFORMER ACCESSORIES
AND CONTROL PANEL ACCESSORIES

Various accessories for transformers, enclosures or control panels:

GA 35 DIN rail adaptor for rail mounting of transformers.


Fuse terminals for transformers from 250V~500V up to 32A.

A4 wiring/document holder for control panels.


Control panel pressure equaliser.
Door switch for controlling lighting.

IP55 filter fan protection hoods to EN60529/10:91.


GA 35 DIN rail adaptor

The GA35 DIN rail adaptor is for mounting standard stock transformers and Images are not to scale
custom built transformers from 25VA to 150VA to DIN rail.

Reference Description Application


GA 35 DIN Din rail fixing bracket For 25VA to 150VA 1ph transformers

The TK 4SI and TK 4SI-32 are specialist transformer fuse terminals for fuse rat-
ings from 250V~500V and from 250mA to 10A.
The FM1038 fuse modules are DIN rail mounted fuse holders for up to 500V
and current ratings from 10A to 32A.
Transformer fuse options

Reference Description Ratings

TK 4SI 5mm x 20mm transformer fuse 250V 250mA up to 10A


Cable size 2.5mm sq
TK 4SI-32 6.3mm x 32mm transformer fuse 500V 1A up to 10A
Cable size 4.0mm sq
FM1038 10mm x 38mm fuse 500V 10A to 32A
Cable size 10mm sq

General enclosure or control panel accessories:


A4 document holder with either screw fixing or adhesive tape fixing.
WJ-1 document holder
PA 65 control panel pressure equaliser permits a controlled change in pressure
and avoids the entry of dust and water.
Door switch with 500mm white cable
PA 65 pressure equaliser
Reference Description Size in mm

WJ-1 A4 diagram/document holder 263 H x 263 W x 30 D

PA 65 Panel pressure equaliser to IP45 65.5 mm diam.


x 30.5mm D
LK4315 Control panel door switch With 500mm cable

Filter fan or exhaust filter hoods to increase IP protection from IP54 to IP55. LK4315 door switch
Supplied in steel and finished in powder coating to RAL 7035.

Reference Description Size in mm

PH10.IP55 To increase filter fan and exhaust filter 195 W x 255 H x 55 D


ratings to IP55
PH20.IP55 To increase filter fan and exhaust filter 325 W x 425 H x 60 D
rating to IP55 PH20 IP55 cover
PH30.IP55 To increase filter fan and exhaust filter 410 W x 540 H x 110 D
rating to IP55

Page 83
SHEET STEEL ENCLOSURES FROM IP22 TO IP65

Three ranges of sheet steel enclosures for housing of transformers


and power equipment.

EPH range of small, low cost enclosures to IP22.

EPN range of floor or wall mounted enclosures to IP23.

ERY range of IP65 enclosures in three types: For either wall or floor
mounting or for portable applications.
EPH enclosure

Images are not to scale


EPH range of small, low cost, ventilated sheet steel enclosures to IP22.
Standard finish is hammer grey and fixing is via four internal fixing points.

Reference L W H Fixing Wiring method


EPH 1 120 95 115 Base mounting 20mm cable entries
EPH 2 145 120 135 Base mounting 20mm cable entries

EPH 3 165 140 150 Base mounting 20mm cable entries

EPN range of universal and ventilated sheet steel enclosures to IP23.


Standard finish is hammer grey and fixing is either floor or wall mounting.
Enclosures up to IP54 in this style also available on request.

Reference L L W H Fixing Wiring method


(ID) (OD) (IP 23 )
EPN 1 127 197 114 194 Floor or wall mounting 20mm cable entries

EPN 2 152 220 152 223 Floor or wall mounting 20mm cable entries

EPN 3 189 270 177 244 Floor or wall mounting 20mm cable entries
EPN enclosure
EPN 4 254 338 215 270 Floor or wall mounting 20mm cable entries

EPN 5 280 350 242 353 Floor or wall mounting 20mm cable entries

EPN 6 305 384 305 454 Floor or wall mounting 20mm cable entries

EPN 7 362 438 334 480 Floor or wall mounting 20mm cable entries

ERY range of fully welded, gasket sealed, sheet enclosures to IP65.


Standard finish is hammer grey and there are three options for mounting,
either W (wall), F (floor) or P (portable with lifting handles).

Reference L W W H Fixing Wiring


(OD) /W or /F /P(OD) method
ERY 3/W (or /F or /P) 293 395 293 353 /W wall /F floor 20mm
or /P portable cable entries
ERY 4/W (or /F or /P) 344 446 344 480 /W wall /F floor 20mm
or /P portable cable entries
ERY 5/W (or /F or /P) 427 529 427 520 /W wall /F floor 20mm
or /P portable cable entries
ERY 6/W (or /F or /P) 554 656 554 640 /W wall /F floor 20mm ERY enclosure
or /P portable cable entries

Page 84
SHEET STEEL ENCLOSURES FROM IP23 TO IP55

Three ranges of sheet steel enclosures for housing transformers and Images are not to scale
power equipment.

ETS range of floor mounting enclosures from IP23 to IP55.

ETT range of floor mounting enclosures from IP23 to IP55.

HDE range of floor mounted enclosures from IP20 to IP55.


ETS and ETT ranges of ventilated sheet enclosures to IP23.
Standard finish is hammer grey and fixing is floor mounting.
Enclosures in IP44, IP54 and IP55 also available in this style on request.
Cable gland plates are fitted to the sides of the enclosure.

Reference L L W W H H Fixing Cooling method


(ID) (OD) (ID) (OD) (ID) (OD)

ETS 1 350 400 350 400 550 600 Adjustable skids Raised lid/open base
ETS 2 400 450 450 500 650 700 Adjustable skids Raised lid/open base
ETS enclosure
ETS 3 550 600 450 500 750 800 Adjustable skids Raised lid/open base

ETT 2 400 420 200 230 400 450 Adjustable skids Raised lid/open base
ETT 3 500 525 350 400 500 550 Adjustable skids Raised lid/open base
ETT 4 600 625 400 454 600 650 Adjustable skids Raised lid/open base
ETT 5 740 770 485 535 760 810 Adjustable skids Raised lid/open base
ETT 6 800 850 600 650 700 775 Adjustable skids Raised lid/open base
ETT 7 1000 1150 700 750 800 875 Adjustable skids Raised lid/open base
ETT 8 1000 1050 800 850 900 975 Adjustable skids Raised lid/open base
ETT 9 1250 1300 800 850 1250 1325 Adjustable skids Raised lid/open base

HDE range of high quality heavy duty, ventilated, sheet enclosures to IP55.
Standard finish is RAL 7035 and fixing is floor mounting. The steel thickness
gives the enclosures a high degree of stability and venting is via a perforated
steel base and unique vent notches under the lid.
Enclosures in IP44, IP54 and IP55 also available in this style on request.
Cable gland plates are fitted to the front and rear of the enclosure.
Ideal for use in conjunction with outdoor enclosures.
ETT enclosure
Reference L L W W H H Fixing Fixing Steel
(ID) (OD) (ID) (OD) (ID) (OD) centres slots thickness
Adjustable x 4x

HDE 110 460 550 400 500 480 510 289~137 x 460 15 x 11 3
HDE 120 520 610 450 550 560 590 349~197 x 510 15 x 11 3
HDE 130 520 610 340 440 420 450 349~197 x 400 15 x 11 3

HDE 140 580 670 400 500 480 510 409~257 x 460 15 x 11 3
HDE 150 680 770 450 550 560 590 509~357 x 510 15 x 11 3
HDE 160 765 855 530 630 620 650 616~332 x 590 15 x 11 3
HDE 170 960 1050 660 760 690 730 812~428 x 720 15 x 11 4
HDE 180 1060 1150 760 860 800 840 891~407 x 820 15 x 11 4
HDE 190 1250 1340 760 860 1250 1290 1081~497 x 820 15 x 11 4
HDE 210 660 750 490 590 590 630 470~406 x 550 15 x 11 4
HDE 220 750 840 400 500 800 840 512~448 x 460 15 x 11 4
HDE 230 850 940 550 650 730 770 590~518 x 610 15 x 11 4
HDE 240 1000 1090 500 600 1000 1040 632~568 x 560 15 x 11 4 HDE enclosure
HDE 250 1200 1290 700 800 1100 1140 812~748 x 760 15 x 11 4

Page 85
TRANSFORMER ENCLOSURES FOR OUTDOOR USE TO IP55

Images are not to scale

A comprehensive range of outdoor transformer enclosures.

Materials include GRP with high U values/thermal performance.

Various fire ratings from 1/2 hour to1 hour.

Various core materials to reduce noise levels and attenuation.

IP rating up to IP55.

Totally bespoke ranges of outdoor use transformer/utility enclosures.


Any size configuration and shape can be produced with lifting eyes
fitted for ease of installation.

Various finishes and colours available on request. Ventilation for


cooling is integral to the design and doors are fully lockable.

Full site preparation and installation can be offered throughout the


whole UK and Northern Ireland. Installers hold a minimum CSCS
and electrical engineers are NIC/EIC registered.

Types include:

Single door utility cabinets


Single skin double door utility cabinets
Large single skin double door utility cabinets
Large double door utility cabinets with 12mm ply core
Double sided, double door utility cabinets

Enclosure type and description Dimensions Door opening


in mm in mm

ET0 to ET6A From 705 H x 225 W


Single door utility cabinets 860 H x 340 W x 200 D to
To 895 H x 705 W
1160 H x 925 W x 600 D

ET6 to ET12 From 870 H x 865 W


Single skin double door utility cabinets 1270 H x 1065 W x 480 D to
To 1310 H x 1735 W
1585 H x 2020 W x 800 D

ET13 to ET16 From 1760 H x 1760 W


Large single skin double door utility 2000 H x 2000 W x 500 D
cabinets To
2000 H x 2000 W x 2000 D

ET17 to ET20 From 1760 H x 1760 W


Large double door utility cabinets 2000 H x 2000 W x 500 D
with 12mm ply core To
2000 H x 2000 W x 2000 D

DET2 to DET8 From 705 H x 225 W


Double sided, double door utility 650 H x 550 W x 800 D to
enclosures To 1090 H x 955 W
1250 H x 1300 W x 800 D

Page 86
GUIDE TO IP RATINGS
PROTECTION OF PERSONS AND THE PROTECTION OF EQUIPMENT

An IP rating is used when specifying the protection of enclosures and covers for electrical or electronic equipment,
from dust, solid objects and fluids.

The first number refers to the protection against dust and solid objects, and the second number refers to the protection
against fluids and moisture.

Protection against solid objects and dust Protection against fluids

First digit Definition Second digit Definition

X Protection unspecified X Protection unspecified


(not stated) (not stated)

0 Non protected 0 Non protected

1 Protection of the back of the hand against 1 Protection against drops of water falling vertically
accidental access to hazardous parts, and
protection of equipment against objects
larger than 50mm.

2 Protection of fingers against access to 2 Protection against drops of water falling vertically
hazardous parts and protection of when the object is tilted up to 15 degrees from
equipment against objects larger than the vertical.
12.5mm.

3 Protection of persons holding tools or wires 3 Protection against spraying water up to


(larger than 2.5mm diameter) and 60 degrees from the vertical.
protection of equipment against objects
larger than 2.5mm.

4 Protection of persons holding small tools or 4 Protection against splashing and spraying water
wires (larger than 1mm diameter) and from all practical directions with limited ingress
protection of equipment against objects permitted.
larger than 1mm.

5 Protection against entry of dust in sufficient 5 Protection against low pressure jets of water
quantity to interfere with the satisfactory from all practical directions with limited ingress
operation of the equipment. permitted.

6 Complete protection against the entry of 6 Protection against heavy seas or a strong jet of
dust. water from all practical directions: e.g. for use on
ships decks.

7 Protection against the effects of immersion


between 15cm and 1m depth.

8 Protection against long periods of immersion


under pressure.
(tests subject to agreement).

Page 87
GUIDE TO HAZARDOUS AREAS
FOR THE USE OF ELECTRICAL EQUIPMENT IN EXPLOSIVE ATMOSPHERES

There is a potential risk of explosion where dangerous mixtures of flammable materials, gas and air, dust and air
or vapours and air exist.

The necessity to remove the sources of ignition for these mixtures or combinations is essential.
Electrical equipment has to be designed, tested and certified before it can be used in these hazardous areas.

Classification of the area

All process plants are divided into either Zones (European or IEC) or Divisions (North American), this is dependent upon the type of
potentially explosive atmosphere present.

Classification Definition of the zone or area Classification


European or IEC North America
Zone 0 (gases) An area where a potentially explosive mixture is Class I Division 1 (gases)
present either continuously or for long periods
Zone 20 (dusts) Class II Division 1 (dusts)

Zone 1 (gases) An area where a potentially explosive mixture Class I Division 1 (gases)
can occur in normal operations
Zone 21 (dusts) Class II Division 1 (dusts)

Zone 2 (gases) An area where a potentially explosive mixture is Class I Division 2 (gases)
not likely to occur during normal operations, but
if it does occur it exists only for short periods
Zone 22 (dusts) Class II Division 2 (dusts)
Class III Division 1 (fibres)
Class III Division 2 (fibres)

Groups of potentially explosive gases, plus dusts and fibres

There are two main gas groups, Group I for underground mining where methane and coal dust are present, and Group II where
gases occur in surface industries allowing equipment to be designed to less onerous tolerances.

Type of gas European or IEC gas group North American gas group
(or material)
Methane I -
Acetylene IIC A
Hydrogen IIC B
Ethylene IIB C
Propane IIA D
Metal dust - E
Coal dust - F
Grain dust - G

Temperature related surfaces that can ignite potentially explosive gases, dusts and fibres

Electrical equipment that can reach high operational temperatures must be classified according to the maximum surface
temperature. This is based on an ambient temperature of 40 degrees Centigrade.

Temperature European North Temperature European North Temperature European North


or IEC American or IEC American or IEC American
450 deg C T1 T1 215 deg C - T2D 135 deg C T4 T4
300 deg C tT2 tT2 200 deg C tT3 T3 120 deg C - T4A
3
280 deg C - T2A 180 deg C - T3A 100 deg C - T5
260 deg C - T2B 165 deg C - T3B 85 deg C - T6
230 deg C - T2C 160 deg C - T3C - - -

Page 88
GLOSSARY OF TERMS

GENERAL
Ambient temperature range
The specified temperature range within which the device is designed to operate.
Efficiency
The ratio of output power to input power expressed as a percentage.
Power de-rating
The required reduction in output power of a device where the specified ambient temperature range is exceeded.
Power factor: (cos-phi)
The ratio of real power to apparent power due to the non sinusoidal shape of the input current.

TRANSFORMERS

VA, kVA and MVA power ratings


The combination of output voltage and output current is the VA rating. Where multiple outputs occur the overall VA
rating is the total VA of all the output windings, kVA is kilovolt amperes. 1kVA is 1000VA and 1MVA is 1000KVA.
Double wound transformer or isolation transformer
A transformer with at least two windings, providing isolation between the input and output circuits.
Autotransformer
A single winding transformer with no isolation between input and output circuits. These transformers can be used
where input and output voltages are very close and space is at a premium.
Input voltage(s)
The supply voltage to the transformer (or primary winding).
Output voltage(s)
The output or load voltage(s) from the transformer (or secondary winding).
Off load and full load
Off load is the where the input to the transformer is powered but no load is being taken. Full load is where the full
rated power of the transformer is being taken.
Insulation class (from Classification of Insulating Materials)
Class Y: 90 deg C rating
Class A: 105 deg C rating
Class E: 120 deg C rating
Class B: 130 deg C rating
Class F: 155 deg C rating
Class H: 180 deg C rating
Class C: above 180 deg C rating
Class I and Class II transformers
Class I: A transformer in which protection against electric shock does not rely on insulation only, but where
provision for earthing is provided and required.
Class II: A transformer in which protection against electric shock does not rely on basic insulation only, but where
double or reinforced insulation is provided. There is no provision for earthing.

POWER SUPPLIES

Transformer rectifier
A combination of conventional transformer and rectifier to convert AC to DC
Switched mode power supply
A power supply that switches the power to a high frequency to reduce size and weight. AC-DC takes AC power and
converts it to DC power. DC-DC takes DC power of one voltage and converts it to DC power of another voltage.

RFI FILTERS

EMC
Electromagnetic compatibility.
RFI
Radio frequency interference.
Residential standard and industrial standard
Residential standard to EN 50081-1, industrial standard to EN 50081-2.

Page 89
February 2016
Catalogue reference
EPP 0216

Eastern Transformers & Equipment Ltd


Units H1 & H2 Overland Business Park
Sudbury Road, Great Whelnetham
Bury St Edmunds, Suffolk, England IP30 0UL

Tel +44 (0) 1284 388033 Fax +44 (0) 1284 386969
Email info@ete.co.uk

For the latest version of our catalogue visit our website

www.ete.co.uk
Go to bottom of home page
PDF downloads

Your local area distributor

electrical power products

You might also like