Diagnosis Report (DR)


VIBRATION ANALYSIS
Intelligenc e in As s et Health
Co llec t/Entry: 02/12/2019 Analys is : 02/12/2019 Nº: 00000459

Plant: COCA-COLA BEVERAGES - PHILIPPINES - ILOILO


Equipment Location
AUXILIARY -> WATER TREATMENT -> RAW WATER PUMP NO. 1, FROM CISTERN -> CISTERN MOTOR NO.1

Diagnosis
Element Failures Det ec t ed Co mpo nent spec if ic at io n Po sit io n
BASE STRUCTURAL LOOSENESS NON DRIVE END

Spectrum used for diagnosis Tendency Curve

Prognosis
Rec o mmended
Recommended action int ervent io n t ime

THE VIBRATION LEVEL INCREASED AT 1 X MACHINE SPEED FREQUENCY. IT IS NORMALLY CAUSED BY DETERIORATED 3 Week(s)
GROUNDING, OR LOOSE HOLD-DOWN BOLTS AT THE BASE. CHECK THESE ITEMS AND GIVE A FEEDBACK TO SEMEQ BEFORE THE
NEXT VIBRATION MEASURMENTS ARE TAKEN.

Analysed by: THIAGO EDUARDO TEIXEIRA Appro ved by: ALEXANDRE DA COSTA PAES

For cus t ome r us e only


PS M/W.O . Interventio n Date Time s pent o n interventio n Equipment do wntime Pe rs on re s pons ible for inte rve ntion

- - - - -

Feedbac k Repo rt (FR)


01. Was the found defect the same as the diagnosed defect? ()Yes ()No, there was no defect ()No, not match.
02. Is the specification of the defective component completly correct? ()Yes ()No
03. Was the indicated position of the defective component correct? ()Yes ()No
04. Was any other intervention performed, in addition to the recommended intervention? ()No ()Yes

Def ec t t ype c lassif ic at io n agreed bet ween SEMEQ/COCA-COLA BEVERAGES - PHILIPPINES - ILOILO

()Success ()Imprecision ()Virtual Defect

Classif ic at io n
analysis agreed
by:
PHILIPPINES - ILOILO S EM EQ

IT.01.03 * FO R030 04/05/19 9 8