You are on page 1of 32

PROJECT:VILLA

SECTION: COLD WATER PIPE SIZING


DATE: 31-07-2017

COLD WATER PIPE SIZING

I.1. Cold Water Flow Required and Riser Pipe Sizing- 01

Item Description Fixture No. U/Flow Rate(l/s)


1 Water Closet (Flush Valve) 10.00
2 Water Closet (Flush Tank) 29 5.00
3 Lavatory 29 2.00
4 Urinal (Flush Valve) 5.00
5 Urinal (Flush Tank) 2 3.00
6 Service Sink 3.00
7 Shower Head 9 4.00
8 Bathtub 9 4.00
9 Laundry 3.00
10 Hose Bib 9 2.00
TOTAL: 87

Total Sanitary Fixture : 87


Total Flow Rate : 299.0
Total Cold Water Flow Rate Required : 5.1

Pipe Sizing Calculated (OD) : 80


Velocity : 1.2
Pressure Drop : 400

I.2. Cold Water Flow Required and Main Pipe Sizing- 02

Item Description Fixture No. U/Flow Rate(l/s)


1 Water Closet (Flush Valve) 10.00
2 Water Closet (Flush Tank) 28 5.00
3 Lavatory 21 2.00
4 Urinal (Flush Valve) 5.00
5 Urinal (Flush Tank) 8 3.00
6 Service Sink 3 3.00
7 Shower Head 17 4.00
8 Bathtub 4.00
9 Laundry 2 3.00
10 Hose Bib 2.00
TOTAL: 79

Total Sanitary Fixture : 79


Total Flow Rate : 289.0
Total Cold Water Flow Rate Required : 5.0

Pipe Sizing Calculated (OD) : 80


Velocity : 1.2
Pressure Drop : 400

Page 1
Page 2
Page 3
T/Flow Rate(l/s)
0.00
145.00
58.00
0.00
6.00
0.00
36.00
36.00
0.00
18.00
299.000

Nos
l/s
l/s

mm
m/s
Pa/m

T/Flow Rate(l/s)
0.00
140.00
42.00
0.00
24.00
9.00
68.00
0.00
6.00
0.00
289.000

Nos
l/s
l/s

mm
m/s
Pa/m

Page 4
Page 5
Page 6
PROJECT:VILLA
SECTION: COLD WATER PIPE SIZING
DATE: 31-07-2017

COLD WATER PIPE SIZING


I. Ground Floor
I.1. Cold Water Flow Required and Main Pipe Sizing- 01

Item Description Fixture No. U/Flow Rate(l/s)


1 Water Closet (Flush Valve) 10.00
2 Water Closet (Flush Tank) 9 5.00
3 Lavatory 9 2.00
4 Urinal (Flush Valve) 5.00
5 Urinal (Flush Tank) 3.00
6 Service Sink 3.00
7 Shower Head 3 4.00
8 Bathtub 3 4.00
9 Laundry 3.00
10 Hose Bib 4 2.00
TOTAL: 28

Total Sanitary Fixture : 28


Total Flow Rate : 95.0
Total Cold Water Flow Rate Required : 2.6

Pipe Sizing Calculated (OD) : 65


Velocity : 1.2
Pressure Drop : 350

I.2. Cold Water Flow Required and Main Pipe Sizing- 02

Item Description Fixture No. U/Flow Rate(l/s)


1 Water Closet (Flush Valve) 10.00
2 Water Closet (Flush Tank) 8 5.00
3 Lavatory 6 2.00
4 Urinal (Flush Valve) 5.00
5 Urinal (Flush Tank) 2 3.00
6 Service Sink 2 3.00
7 Shower Head 4 4.00
8 Bathtub 4.00
9 Laundry 2 3.00
10 Hose Bib 2.00
TOTAL: 24

Total Sanitary Fixture : 24


Total Flow Rate : 86.0
Total Cold Water Flow Rate Required : 2.5

Pipe Sizing Calculated (OD) : 65


Velocity : 1.2
Pressure Drop : 350

Page 7
Page 8
Page 9
T/Flow Rate(l/s)
0.00
45.00
18.00
0.00
0.00
0.00
12.00
12.00
0.00
8.00
95.000

Nos
l/s
l/s

mm
m/s
Pa/m

T/Flow Rate(l/s)
0.00
40.00
12.00
0.00
6.00
6.00
16.00
0.00
6.00
0.00
86.000

Nos
l/s
l/s

mm
m/s
Pa/m

Page 10
Page 11
Page 12
PROJECT:VILLA
SECTION: COLD WATER PIPE SIZING
DATE: 31-07-2017

COLD WATER PIPE SIZING


I. Mezzanine Floor
I.1. Cold Water Flow Required and Main Pipe Sizing- 01

Item Description Fixture No. U/Flow Rate(l/s)


1 Water Closet (Flush Valve) 10.00
2 Water Closet (Flush Tank) 9 5.00
3 Lavatory 9 2.00
4 Urinal (Flush Valve) 5.00
5 Urinal (Flush Tank) 3.00
6 Service Sink 3.00
7 Shower Head 3 4.00
8 Bathtub 3 4.00
9 Laundry 3.00
10 Hose Bib 2.00
TOTAL: 24

Total Sanitary Fixture : 24


Total Flow Rate : 87.0
Total Cold Water Flow Rate Required : 2.0

Pipe Sizing Calculated (OD) : 50


Velocity : 1.2
Pressure Drop : 350

I.2. Cold Water Flow Required and Main Pipe Sizing- 02

Item Description Fixture No. U/Flow Rate(l/s)


1 Water Closet (Flush Valve) 10.00
2 Water Closet (Flush Tank) 6 5.00
3 Lavatory 4 2.00
4 Urinal (Flush Valve) 5.00
5 Urinal (Flush Tank) 2 3.00
6 Service Sink 3.00
7 Shower Head 4 4.00
8 Bathtub 4.00
9 Laundry 3.00
10 Hose Bib 2.00
TOTAL: 16

Total Sanitary Fixture : 16


Total Flow Rate : 60.0
Total Cold Water Flow Rate Required : 2.0

Pipe Sizing Calculated (OD) : 50


Velocity : 1.2
Pressure Drop : 300

Page 13
Page 14
Page 15
T/Flow Rate(l/s)
0.00
45.00
18.00
0.00
0.00
0.00
12.00
12.00
0.00
0.00
87.000

Nos
l/s
l/s

mm
m/s
Pa/m

T/Flow Rate(l/s)
0.00
30.00
8.00
0.00
6.00
0.00
16.00
0.00
0.00
0.00
60.000

Nos
l/s
l/s

mm
m/s
Pa/m

Page 16
Page 17
Page 18
PROJECT:VILLA
SECTION: COLD WATER PIPE SIZING
DATE: 31-07-2017

COLD WATER PIPE SIZING


I. First Floor
I.1. Cold Water Flow Required and Main Pipe Sizing- 01

Item Description Fixture No. U/Flow Rate(l/s)


1 Water Closet (Flush Valve) 10.00
2 Water Closet (Flush Tank) 9 5.00
3 Lavatory 9 2.00
4 Urinal (Flush Valve) 5.00
5 Urinal (Flush Tank) 3.00
6 Service Sink 3.00
7 Shower Head 3 4.00
8 Bathtub 3 4.00
9 Laundry 3.00
10 Hose Bib 2.00
TOTAL: 24

Total Sanitary Fixture : 24


Total Flow Rate : 87.0
Total Cold Water Flow Rate Required : 2.5

Pipe Sizing Calculated (OD) : 65


Velocity : 1.2
Pressure Drop : 350

I.2. Cold Water Flow Required and Main Pipe Sizing- 02

Item Description Fixture No. U/Flow Rate(l/s)


1 Water Closet (Flush Valve) 10.00
2 Water Closet (Flush Tank) 8 5.00
3 Lavatory 7 2.00
4 Urinal (Flush Valve) 5.00
5 Urinal (Flush Tank) 2 3.00
6 Service Sink 1 3.00
7 Shower Head 5 4.00
8 Bathtub 1 4.00
9 Laundry 3.00
10 Hose Bib 2.00
TOTAL: 24

Total Sanitary Fixture : 24


Total Flow Rate : 87.0
Total Cold Water Flow Rate Required : 2.5

Pipe Sizing Calculated (OD) : 65


Velocity : 1.2
Pressure Drop : 350

Page 19
Page 20
Page 21
T/Flow Rate(l/s)
0.00
45.00
18.00
0.00
0.00
0.00
12.00
12.00
0.00
0.00
87.000

Nos
l/s
l/s

mm
m/s
Pa/m

T/Flow Rate(l/s)
0.00
40.00
14.00
0.00
6.00
3.00
20.00
4.00
0.00
0.00
87.000

Nos
l/s
l/s

mm
m/s
Pa/m

Page 22
Page 23
Page 24
PROJECT:VILLA
SECTION: COLD WATER PIPE SIZING
DATE: 31-07-2017

COLD WATER PIPE SIZING


I. Second Floor
I.1. Cold Water Flow Required and Main Pipe Sizing- 02

Item Description Fixture No. U/Flow Rate(l/s)


1 Water Closet (Flush Valve) 10.00
2 Water Closet (Flush Tank) 6 5.00
3 Lavatory 4 2.00
4 Urinal (Flush Valve) 5.00
5 Urinal (Flush Tank) 2 3.00
6 Service Sink 3.00
7 Shower Head 4 4.00
8 Bathtub 4.00
9 Laundry 3.00
10 Hose Bib 2.00
TOTAL: 16

Total Sanitary Fixture : 16


Total Flow Rate : 60.0
Total Cold Water Flow Rate Required : 2.0

Pipe Sizing Calculated (OD) : 50


Velocity : 1.2
Pressure Drop : 300

Page 25
Page 26
T/Flow Rate(l/s)
0.00
30.00
8.00
0.00
6.00
0.00
16.00
0.00
0.00
0.00
60.000

Nos
l/s
l/s

mm
m/s
Pa/m

Page 27
Page 28
PROJECT:VILLA
SECTION: COLD WATER PIPE SIZING
DATE: 31-07-2017

COLD WATER PIPE SIZING


I. Roof Floor
I.1. Cold Water Flow Required and Main Pipe Sizing- 01

Item Description Fixture No. U/Flow Rate(l/s)


1 Water Closet (Flush Valve) 10.00
2 Water Closet (Flush Tank) 2 5.00
3 Lavatory 2 2.00
4 Urinal (Flush Valve) 5.00
5 Urinal (Flush Tank) 2 3.00
6 Service Sink 3.00
7 Shower Head 4.00
8 Bathtub 4.00
9 Laundry 3.00
10 Hose Bib 5 2.00
TOTAL: 11

Total Sanitary Fixture : 11


Total Flow Rate : 30.0
Total Cold Water Flow Rate Required : 1.3

Pipe Sizing Calculated (OD) : 40


Velocity : 1.2
Pressure Drop : 400

Page 29
Page 30
T/Flow Rate(l/s)
0.00
10.00
4.00
0.00
6.00
0.00
0.00
0.00
0.00
10.00
30.000

Nos
l/s
l/s

mm
m/s
Pa/m

Page 31
Page 32