EMS DATA ACQUISITION AND


Electric Power / Controls MANAGEMENT (LVDAM-EMS)
0.2 kW MODEL 9062

GENERAL DESCRIPTION
The Lab-Volt Data Acquisition and Management for The LVDAM-EMS system consists of a data
Electromechanical Systems (LVDAM-EMS), acquisition interface (DAI) module and the Lab-Volt
Model 9062, is a computer-based system for measuring, software Data Acquisition and Management for
observing, and analyzing electrical and mechanical Electromechanical Systems (LVDAM-EMS). The
parameters in electric power systems and power LVDAM-EMS system is an add-on to several Lab-Volt
electronics circuits. It allows training in various areas, systems, such as the 0.2-kW Electromechanical Training
such as electric power technology, AC/DC machines, System, Model 8001, the Power Electronics Training
and power electronics, using modern and versatile System, Model 8032, and the 0.2-kW Electric Power
measuring instruments. The user guide (P/N 36221-E0) Transmission Training System, Model 8055. It is a
provided with the LVDAM-EMS system allows students standard feature of the Lab-Volt Computer-Assisted
to become familiar with the instruments quickly. 0.2-kW Electromechanical Training System, Model 8006.

(732) 938-2000 / 800-LAB-VOLT, FAX: (732) 774-8573, E-MAIL: us@labvolt.com


(418) 849-1000 / 800-LAB-VOLT, FAX: (418) 849-1666, E-MAIL: ca@labvolt.com
INTERNET: http: //www.labvolt.com
EMS DATA ACQUISITION AND MANAGEMENT (LVDAM-EMS)
MODEL 9062

Data Acquisition Interface The DAI module is available in two versions:


The Data Acquisition Interface (DAI) module consists of Models 9062-1 and 9062-B. The DAI module,
isolation and data acquisition units. The isolation unit Model 9062-1, is enclosed in a half-height standard EMS
converts high-level voltages and currents measured in module. This version requires 24-V AC power available
electric power systems and power electronics circuits in the Lab-Volt training systems mentioned above. The
into low-level signals, and routes these signals to the DAI module, Model 9062-B, is a bench-top version with
data acquisition unit. The data acquisition unit converts a built-in power supply. It can be powered from any
the low-level signals into digital numbers (data) that are standard wall outlet.
sent to the personal computer that runs the LVDAM- Interconnection between the DAI module and the
EMS software. computer is made through a standard USB cable
The DAI module has isolated voltage and current included with the module.
inputs fitted with 4-mm banana safety jacks, which can
LVDAM-EMS Software
be connected to AC or DC power circuits. Low-level
inputs for torque and speed measurement can be The LVDAM-EMS software consists of a set of
connected to the Prime Mover / Dynamometer, conventional and specialized instruments that run on an
Model 8960, which provides output signals proportional IBM®-compatible personal computer under the
to torque and speed. Eight software-programmable, low- Microsoft® Windows® operating environment. Each
level, auxiliary analog inputs allow measurement of instrument appears as a window on the computer
additional circuit parameters. Two analog outputs, also screen. The conventional instruments include AC/DC
software-programmable, allow direct control of the Prime voltmeters and ammeters, power meters, and an eight-
Mover / Dynamometer, or of the Power Electronics channel oscilloscope. The specialized instruments
modules to which they are connected. All inputs and include a six-channel phasor analyzer, a harmonic
outputs are protected against wrong connections and analyzer, a spectrum analyzer, torque, speed, and
overvoltage/overcurrent conditions. The user guide mechanical power meters, and six user-programmable
included with the DAI module provides detailed meters. The LVDAM-EMS software is also provided with
information about the module operation. data-recording and graph-plotting facilities. The various
instruments are briefly described in the next section of
this datasheet.

LVDAM-EMS INSTRUMENTS
Metering
The Metering window can include up to eighteen meters,
which can be configured for measuring voltage and
current, electrical power (active, reactive, and apparent),
torque, speed, mechanical power, etc. The voltage and
current meters have several modes of operation that
allow measurement of the mean (DC) value, RMS value,
crest factor, RMS value of a particular harmonic (up to
the 15th), RMS value of the harmonics, and total
harmonic distortion (THD). Six of the eighteen meters
are user-programmable for access to a larger variety of
functions, allowing measurement of power factor,
efficiency, impedance, frequency, energy, phase shift,
etc. The arrangement (layout) of the meters in the
Metering window can be customized by the user.
Data Table and Graph
The values indicated by the various meters in the
Metering window, as well as values measured by the
other instruments in LVDAM-EMS, can be recorded in
the Data Table window with a click of the mouse. The
values recorded in the Data Table can be saved to a file
(ASCII-formatted file). The recorded data can also be
used to plot graphs by selecting which parameter(s) to
plot in the Graph window. This allows lab results to be
plotted quickly and easily. More sophisticated graphs
can be created by exporting the contents of the Data
Table window to any popular spreadsheet program, such
as Microsoft® Excel® directly through the Windows®
Clipboard.

Oscilloscope
The Oscilloscope can display up to eight waveforms
simultaneously. The waveforms are displayed using
different colors to simplify identification. Each channel
has independent vertical controls similar to those found
on conventional oscilloscopes. An automatic scale-
setting function allows the sensitivity of each channel to
be set automatically according to the magnitude of the
observed parameter. The time base and trigger controls
are similar to those found on most oscilloscopes to
simplify adjustment. The RMS value, average value, and
frequency of each of the observed parameters can be
displayed in a table in the Oscilloscope window. Two
vertical cursors can be activated to perform precise
measurements at particular points on the displayed
waveforms. The Oscilloscope has two memories for
saving the displayed waveforms.
EMS DATA ACQUISITION AND MANAGEMENT (LVDAM-EMS)
MODEL 9062

Phasor Analyzer
The innovative Phasor Analyzer allows students to
analyze AC power circuits with the phasors related to
voltages and currents instead of the values and
waveforms of these voltages and currents. Circuit
voltages and currents can be monitored easily for
relative amplitudes and phase differences simply by
looking at their respective phasors on the Phasor
Analyzer display. This produces a unique and dynamic
display of the voltages and currents in a circuit
(especially in three-phase circuits) that cannot be
obtained with conventional instruments. The RMS value,
phase angle, and frequency of the voltage or current
related to each phasor is displayed in a table in the
Phasor Analyzer window.

Harmonic Analyzer
The Harmonic Analyzer allows observation and analysis
of the harmonic components in voltages and currents.
The fundamental frequency can be set to the AC power
network frequency, set manually by the user, or set
automatically to the frequency of the fundamental
component of the selected voltage or current. The
number of harmonic components displayed can be
varied between 5 and 40. The harmonic components of
the selected voltage or current can be displayed using a
vertical scale graduated in either absolute or relative
values. Various vertical scale settings are available. A
group of data displays in the Harmonic Analyzer
indicates the values of the DC component, fundamental
component, and harmonic components of the selected
voltage or current, as well as the total harmonic
distortion (THD). Vertical and horizontal cursors can be
activated to perform precise measurements at particular
points on the display.
Spectrum Analyzer
The Spectrum Analyzer allows frequency-domain
observation and analysis of voltages and currents. It is
a frequency-selective instrument that measures the level
of the frequency components in the selected voltage or
current, and displays the results on a graduated screen.
The vertical scale of the screen can be either linear or
logarithmic. The center frequency is set manually or
using the Seek function which searches for the next
frequency component in the observed spectrum. Various
frequency spans can be selected to display the observed
frequency spectrum. Vertical and horizontal cursors can
be activated to perform precise measurements at
particular points on the frequency spectrum displayed on
the graduated screen. The Spectrum Analyzer has two
memories for saving frequency spectra.
EMS DATA ACQUISITION AND MANAGEMENT (LVDAM-EMS)
MODEL 9062

SPECIFICATIONS
Model 9062 – Data Acquisition Interface 120/208 V – 60 Hz 220/380 V – 50 Hz 240/415 V – 50 Hz
Voltage Inputs (3) Range (software programmable) !400 to +400 V,
!750 to +750 V, !200 to +200 V
!100 to +100 V
Frequency Bandwidth DC to 10 kHz
Accuracy 1%
Isolation 750 V
Current Inputs (3) Range (software programmable) !12 to +12 A,
!6 to +6 A, !1.5 to +1.5 A
!3 to +3 A
Frequency Bandwidth DC to 10 kHz
Accuracy 1%
Torque Input Range !3 to +3 NAm (!27 to +27 lbfAin)
Torque-to-Voltage Ratio 0.3 NAm / V (2.66 lbfAin / V)
Accuracy 0.1% of reading ±1 bit
Speed Input Range !5000 to +5000 r/min.
Speed-to-Voltage Ratio 500 r/min. / V
Accuracy 0.1% of reading ±1 bit
Auxiliary Analog Inputs (8) Voltage Range !10 to +10 V
Type of Measured Parameter user selectable through software
Parameter-to-Voltage Ratio user determined through software
Accuracy 0.1% of reading ±1 bit
Synchronization Input Level TTL
Analog Outputs (2) Voltage Range !10 to +10 V
A/D Converter Number of Multiplexed Channels 16
Resolution 12 bits
Multiple-Channel Maximum Sampling Rate 180 ksamples/s
D/A Converter Number 2
Resolution 12 bits
USB Port Interconnection Cable Length 3.0 m
Power Requirement Model 9062-1 24 V – 0.4 A – 50/60 Hz
Model 9062-B 120 V – 0.2 A – 60 Hz 220 V – 0.1 A – 50 Hz 240 V – 0.1 A – 50 Hz
Physical Characteristics Dimensions (H x W x D): Model 9062-1 154 x 287 x 440 mm (6.1 x 11.3 x 17.3 in)
Model 9062-B 162 x 330 x 300 mm (6.4 x 13.0 x 11.8 in)
Net Weight: Model 9062-1 7.2 kg (15.9 lb)
Model 9062-B 5.0 kg (11.0 lb)
LVDAM-EMS Software 120/208 V – 60 Hz 220/380 V – 50 Hz 240/415 V – 50 Hz
Metering Number of Meters 18
Sampling Window 250 ms of software adjusted (11.4 to 819 ms)
Sampling Frequency (each meter) 3.84 kHz or
3.2 kHz or software adjusted
software adjusted
(625.3 Hz to 11.2 kHz)
625.3 Hz to 11.2 kHz
Display Type digital or analog, user selectable through software
Oscilloscope Number of Channels 8
Vertical Sensitivity 2 V/div. to 200 V/div.
Time Base 0.2 ms/div. to 10 s/div.
Sampling Window 20 x selected time base
Sampling Frequency 301 samples per measured parameter per horizontal sweep, up to a
maximum of 180 kHz
SPECIFICATIONS (cont'd)
LVDAM-EMS Software (cont'd) 120/208 V – 60 Hz 220/380 V – 50 Hz 240/415 V – 50 Hz
Phasor Analyzer Sensitivity 2 V/div. to 100 V/div., 5 V/div. to 200 V/div.,
0.1 A/div. to 5 A/div. 0.05 A/div. to 2 A/div.
Sampling Window software adjusted (17.1 to 307 ms)
Sampling Frequency (each phasor) software adjusted (1.667 to 30 kHz)
Harmonic Analyzer Fundamental-Frequency Range 1 Hz to 200 Hz
Number of Harmonic Components 5 to 40, user selectable through software
Vertical Scale (relative scale) 0.1%/div. to 10%/div.
Vertical Scale (absolute scale) 0.5 V/div. to 50 V/div., 0.01 A/div. to 1 A/div.
Sampling Window software adjusted (10 ms to 15 s)
Sampling Frequency software adjusted (120 Hz to 180 kHz)
Spectrum Analyzer Frequency Range DC to 5 kHz
Frequency Resolution 1.22 Hz
Frequency Span 20 Hz/div. to 1 kHz/div.
Maximum Input 100 mV to 1000 V, 2.5 mA to 25 A
Sampling Window 0.8192 s
Sampling Frequency 10 kHz

PERSONAL COMPUTER REQUIREMENTS


A Pentium-type personal computer with USB port, running under one of the following Microsoft® operating systems,
Windows® 98, Windows® 2000, Windows® Millennium or Windows® XP, is required.

ORDERING NUMBERS
120/208 V – 60 Hz 220/380 V – 50 Hz 240/415 V – 50 Hz
ENGLISH FRENCH SPANISH ENGLISH FRENCH SPANISH ENGLISH
9062-10 9062-11 9062-12 9062-15 9062-16 9062-17 9062-15
9062-B0 9062-B1 9062-B2 9062-B5 9062-B6 9062-B7 9062-BA
36221-E0 36221-E1 36221-E2 36221-E0 36221-E1 36221-E2 36221-E0
Table 1. Equipment Ordering Numbers
Reflecting Lab-Volt's commitment to high quality standards in product, design, development, production, installation, and service, our manufacturing and distribution
facility has received the ISO 9001 certification.

Lab-Volt reserves the right to make product improvements at any time and without notice and is not responsible for typographical errors. Lab-Volt recognizes all product
names used herein as trademarks or registered trademarks of their respective holders. © Lab-Volt 2007. All rights reserved.