You are on page 1of 1

GINOS ENGINEERS PTY LTD

Consulting Engineers
A.B.N. 82 082 586 178
FOUNDATION RECOMMENDATIONS
2nd floor, 185 Victoria Square
Adelaide SA 5000 CONSTRUCTION
PO Box 2756
Adelaide SA 5001
Telephone: (08) 8212 4900
Facsimile: (08) 8212 3829
Email: email@ginosengineers.com.au SR1

Job No 27831/F 06.08.15

Client WEEKS BUILDING GROUP VICTORIA


Proprietor R & K LOPEZ
Site LOT 14 NO 15 PITT STREET FAWKNER

Building DOUBLE STOREY ARTICULATED BRICK VENEER / RENDAPANEL RESIDENCE

Note: Footing details contained herein are to be read in conjunction with the footing layout plan prepared by the Engineer,
standard construction details and the Specifications for footing construction.
The footing type recommended is considered the most appropriate for the site and proposed building and in compliance with AS
2870 - 2011, Australian Standard Residential Slabs and Footings - Construction.

Footing Type: 1. RC Waffle Pod founded on firm natural ground via piers.
2. Slab on ground to be 120mm thick reinforced with SL92 fabric placed at
25mm from the top surfaces (u.n.o)

Footing Beam DxB Reinforcement Ligatures


Details
External

Internal REFER TO
ATTACHMENT
SR3/C

Attachments: SR2, FOOTING COMPUTATIONS, SPECIFICATION, WP5, WP6, WPS, BJ,


SRP, SP1, SDS, FC1, CSIRO NOTES (Owner’s Copy only), CJ/A, SR2-1/F,
SR3/C

Notes: 1. Design Wind Rating = W33 (N2)


Stormwater Drainage
It is extremely important for proper functioning of the recommended footings to ensure adequate stormwater disposal.
The site and drainage plan indicates minimum requirements for stormwater disposal.

General

It is imperative that the Owner is aware of his responsibilities with regard to site management. The Owner’s attention is drawn to
the CSIRO Division of Building Research pamphlet - “Guide to Home Owners on Foundation Maintenance and Footing
Performance”.