You are on page 1of 60

Mechanical

Level Switches
Form 912

SOR® mechanical level switches


are rugged, industrial products specifically
designed for versatility of application. This catalog
contains application and ordering data for float and
displacer-operated level switches. Switches are 200 Series
available with flanged or sealed chambers or
as insertion models.

Options available for each type of switch


include: switch type and number, housing type,
chamber material, process connections,
accessories, and more. Units may be
customized to suit customers’ needs.

Inside this catalog you will find solutions to


your level sensing puzzles. SOR mechanical
level switches have many configurations
available. If you don’t see what you need, we 100 Series
will engineer a solution for your application.

700 Series

• Five-year warranty
Features and Benefits

• ASME Section IX and AWS qualified welding system


• Designed to ANSI/ASME B31.1 and B31.3 guidelines
• Hermetically sealed switching mechanisms available
• Stainless steel switching mechanisms
• High-temperature capability
• Wide variety of explosion-proof housings
• Versatile switching mechanisms which retro-fit into other manufacturers’ units
• Worldwide listings and certifications
• Quick worldwide delivery
• Only ASTM grade materials with certified mill test reports used

sorinc.com Registered Quality System to ISO 9001:2008 913-888-2630


Mechanical
Level Switches

300
Top 700 Series
Mounted Top
Float Mounted
Displacer

Sealed Chamber Float


Flanged Chamber Float

200 Series
100 Series

208 Steam Trap Float

400 Series
Side Mounted Float

Form 912 sorinc.com


2/60 Registered Quality System to ISO 9001:2008 913-888-2630
Mechanical
Level Switches Table of Contents

Section Page

Principles...........................................................................................................4
Features and Benefits...................................................................................6
How to Order....................................................................................................8
Float Switches
100 Series Flanged External Cage................................................... 9
200 Series Sealed External Cage................................................... 14
108/208 Series Steam Condensate External Cage.................. 18
300 Series Top Insertion Mount...................................................... 20
400 Series Side Insertion Mount.................................................... 23
Displacer Switches
Models 741-743, 801, and 802 Flanged External Cage........... 26
Models 740, 803, and 804 Sealed External Cage..................... 30
700 Series Single-Stage Top Insertion Mount............................. 33
730 Series Dual-Stage Top Insertion Mount................................ 36
750 Series Triple-Stage Top Insertion Mount.............................. 40
Switching Mechanisms.............................................................................. 44
Switch Ratings ............................................................................................. 47
Housings......................................................................................................... 48
Accessories
Compatibility Chart............................................................................. 49
Test Certificates................................................................................... 50
High Temperature Selection............................................................. 51
CY and CZ Option Inspection Requirements.............................. 55
MC and TC Options........................................................................... 56
ASTM Material Designations............................................................ 57
Reference Charts
Specific Gravity of Water.................................................................. 58
Conversions......................................................................................... 59
Weights................................................................................................. 60

sorinc.com Form 912


913-888-2630 Registered Quality System to ISO 9001:2008 3/60
Mechanical
Level Switches Principles
Float-Operated Level Switches
Model Series 100, 200 and 300
The float rides on the process liquid surface,
precisely tracking liquid surface motion. Switching Element
Common
Rising liquid level lifts the float, sliding the attraction
Normally Open
sleeve up inside the enclosing tube and into the Normally Closed
magnetic field to actuate the electrical or
Pivot
pneumatic switch (signaling liquid presence).
Bias Spring

Subsequently, falling liquid level lowers the float, Magnet

drawing the attraction sleeve out of the magnetic Attraction Sleeve


Enclosing Tube
field to deactuate the electrical or pneumatic switch
(signaling liquid absence). Float-type level switches
are generally able to handle high-temperature Float
applications, and sometimes prove useful for close
interface detection. Level
Differential
Floats can operate up to three switching elements.
Independent switching levels may be obtained with Actuated Deactuated
tandem floats. Consult the factory for special float-
switching arrangements.

Float-Operated Level Switches


Model Series 108/208 and 400
The float rides on the process liquid surface, precisely tracking liquid surface motion.
Rising liquid level lifts the float via a pivot mechanism, sliding the attraction sleeve down inside
the enclosing tube and out of the magnetic field to deactuate the electrical or pneumatic switch
(signaling liquid presence).
Subsequently, falling liquid level lowers the float, drawing the attraction sleeve into the magnetic field
to actuate the electrical or pneumatic switch (signaling liquid absence). Float-type level switches are
generally able to handle high-temperature applications.

Switching Switching
Element Element
Actuated C Common Deactuated C Common
Magnetic NC Normally Closed NC Normally Closed
Magnetic
Field NO Normally Open NO Normally Open
Field
Engaged
Disengaged

Attraction Bias Spring Attraction Bias Spring


Sleeve Up Enclosing Tube Sleeve Enclosing Tube
Down
Counterweight

Level
Differential

Actuated Deactuated
Form 912 sorinc.com
4/60 Registered Quality System to ISO 9001:2008 913-888-2630
Mechanical
Level Switches Principles

Displacer-Operated Level Switches


Model Series 700, 730, 740, 750 and 800

Displacer controls offer alternative features to


the float-operated control. The sensor is a
Switching Element
weight (displacer), heavier than the liquid, that
Common
is suspended by a spring. When liquid contacts
Normally Open
the displacer, a buoyancy force is produced,
Normally Closed
which causes the effective weight of the
Pivot
displacer to change. This causes the spring to
Bias Spring
retract slightly to a new equilibrium position.
Magnet
When the spring retracts, the attraction sleeve
Attraction Sleeve
also moves upward into the field of the external
Enclosing Tube
magnet, thus overcoming the force of the bias
Extension Spring
spring and actuating the switching element.
Suspension Rod / Cable

This principle provides for narrow or wide Displacer

switching differential, and allows switching point


alteration by moving the displacer(s) up or down Level
Differential
the suspension cables.

Displacers may be arranged in combinations Actuated Deactuated


of narrow and wide differential to operate up
to three switching stages. Displacer controls
operate under higher pressure conditions than
float-operated switches.

sorinc.com Form 912


913-888-2630 Registered Quality System to ISO 9001:2008 5/60
Mechanical
Level Switches Features and Benefits

General
Features and Benefits

 Rugged carbon steel or stainless steel construction


 Five-year manufacturer’s warranty
 Quick, worldwide delivery
 All ASTM materials (see page 57)
 Quality management system is registered to ISO-9001:2000

Standard Chamber Materials


 All SOR level switch chambers are constructed using ASTM grade materials
with full material certification. Mill Test Reports are kept on file for all raw materials.
Copies are available upon request at the time of order placement.

Carbon Steel Construction


Chamber Center Section A106 Grade B
Flanges/Weld Fittings A105
Weld Cap A234-WPB
Studs/Nuts A193-B7/A194-2H

Stainless Steel Construction


Chamber Center Section A312-TP316/316L
Flanges/Weld Fittings A182-316/316L
Weld Cap A403-316/316L
Studs/Nuts A193-B7/A194-2H

Gaskets
 All standard models are provided with a Nitrile binder composite gasket that is
selected for its resistance to hydrocarbons and steam.
 For high-temperature, high-pressure or NACE-constructed units, a spiral-wound
gasket is used with 316SS wound-around Grafoil.
 Extreme high-pressure model 802 uses a soft-iron, ring-joint gasket on the chamber
head flange.

Internal Trim
 All sensing elements (floats and displacers) are constructed of either
316/316LSS or porcelain as a minimum.
 Attraction sleeves are available in 400SS as a standard, with 316/316LSS or

other exotic metals as an option.


 All other wetted internal parts are 316SS or better. Displacer springs are made

of Inconel 600.

Form 912 sorinc.com


6/60 Registered Quality System to ISO 9001:2008 913-888-2630
Mechanical
Level Switches Features and Benefits

Switching Mechanisms
Features and Benefits
SOR switching mechanisms are designed for use in punishing industrial conditions.
 All stainless steel construction - no aluminum or brass.

 Temperature ratings available from -65°F (–54°C) to 1000°F (538°C) on

dry, non–condensing services.


 Condensing service (steam) temperature ratings available up to 800°F (427°C),

and up to 1200°F (649°C) with protection (see page 52).


 Available switching mechanisms include hermetically sealed, standard open

contacts, or pneumatic contacts.


 Agency listings are available on most switch mechanisms: UL, CSA, ATEX

or SAA (Australia).

Switch Housings
All SOR switch housings are made from rugged castings. Materials are
copper-free aluminum or cast iron. A wide range of explosion-proof ratings and
agency listings are available.

Quality Assurance
SOR maintains a high level of quality throughout our corporation. Many quality
assurance features are built into our products.
 ISO 9001 certified engineering design and production system (certified

since 1993).
 Level-welded chambers designed to the guidelines of ASME B31.1 and

B31.3 (inspection certificate available – see page 55).


 All welders and weld procedures are qualified and maintained to

ASME Section IX.


 All ASTM grade materials used - Certified Mill Test Reports required on

all raw materials.

Product Support
SOR has a full-time engineering staff dedicated to solving your mechanical level
switch problems.
 Engineers and technicians are knowledgeable about sales and production
techniques, and are dedicated to providing the best solution to our customers
at the best price.

sorinc.com Form 912


913-888-2630 Registered Quality System to ISO 9001:2008 7/60
Mechanical
Level Switches How to Order

Model Number System

101 A-A1C-B-A1-N4-CRTT
Model Series Chamber Process Connection Internal Switch Housing Accessories
Material Trim Mechanism
Material

The level switch model number is divided into seven sections that individually specify the
components of an SOR level switch. This diagram illustrates the model number arrangement.
Select the component designators from the appropriate pages of this brochure. Standard
components and ratings are highlighted throughout the brochure for ease of use.
Each section includes a valid model number at the top of each listing of component designators.
The position of the designator listed below it will be shown in color for reference.

How to Order
Steps 1 through 5 are required; Step 6 is optional. Orders must have complete model numbers,
i.e. each component must have a designator.

Step 1: Select Model Series based on maximum working pressure and minimum
specific gravity.

Step 2: Select Chamber Material.

Step 3: Select Process Connection.

Step 4: Select Trim Material.

Step 5: Select Switch Mechanism & Housing. (Pages 44 through 48).

Step 6: Select Accessories as required for service. (Page 49).

Page Numbers for Selected Steps


741, 743, 740, 803
100 200 108/208 300 400 700 730 750
Step 802 and 804
Series Series Series Series Series Series Series Series
Series Series
1 9 14 18 20 23 26 30 33 36 40
2 10 15 18 20 23 26 30 33 36 40
3 10 15 18 21 24 27 31 34 37 41
4 10 15 18 21 24 27 31 34 37 41
5 44-48 44-48 44-48 44-48 44-48 44-48 44-48 44-48 44-48 44-48
6 49 49 49 49 49 49 49 49 49 49

Design and specifications are subject to change without notice. For latest revision, see www.sorinc.com.

Form 912 sorinc.com


8/60 Registered Quality System to ISO 9001:2008 913-888-2630
100 Series Step 1: Model Series
101 A-A1C-B-A1-N4-CRTT
The 100 Series mechanical liquid level switch is float operated with a flanged, serviceable external
chamber. Select the sensing unit from the following charts. Then refer to pages 44 through 50 for
switching elements, housings and accessories.
Select a model series from the charts below based on maximum operating pressure and minimum
specific gravity.
Maximum Working Pressure
See page 53 for pressure ratings at higher temperatures.

Model Chamber Pressure at Listed Temperature in psid (bar)*


Series Material 100°F (38°C) 200°F (93°C) 300°F (149°C) 350°F (177°C) 400°F (204°C) 450°F (232°C)
A106B 285 (19.7) 260 (17.9) 230 (15.9) 215 (14.8) 200 (13.8) 185 (12.8)
101
316SS 275 (18.9) 235 (16.2) 215 (14.8) 205 (14.1) 195 (13.4) 182 (12.6)
A106B 500 (34.5) 500 (34.5) 500 (34.5) 486 (33.5) 473 (32.6) 460 (31.7)
102
316SS 500 (34.5) 500 (34.5) 500 (34.5) 486 (33.5) 473 (32.6) 460 (31.7)
A106B 740 (51.0) 675 (46.6) 655 (45.2) 645 (44.5) 635 (43.8) 622 (42.9)
103
316SS 720 (49.7) 620 (42.8) 560 (38.6) 537 (37.0) 515 (35.5) 497 (34.3)
A106B 990 (68.2) 900 (62.0) 875 (60.3) 860 (59.2) 845 (58.2) 822 (56.6)
104
316SS 1000 (69.0) 1000 (69.0) 1000 (69.0) 973 (67.1) 946 (65.2) 920 (63.4)
A106B 285 (19.7) 280 (17.9) 230 (15.9) 215 (14.8) 200 (13.8) 185 (12.8)
109
316SS 275 (18.9) 235 (16.2) 215 (14.8) 205 (14.1) 195 (13.4) 182 (12.6)
A106B 285 (19.7) 260 (15.9) 230 (15.9) 215 (14.8) 200 (13.8) 185 (12.8)
121
316SS 275 (18.9) 235 (14.8) 215 (14.8) 205 (14.1) 195 (13.4) 182 (12.6)
A106B 350 (24.1) 350 (24.1) 350 (24.1) 340 (23.4) 331 (22.8) 322 (22.2)
122
316SS 350 (24.1) 350 (24.1) 350 (24.1) 340 (23.4) 331 (22.8) 322 (22.2)
A106B 740 (51.0) 675 (46.6) 655 (45.2) 645 (44.5) 635 (43.8) 622 (42.9)
123
316SS 720 (49.7) 620 (42.8) 560 (38.6) 537 (37.0) 515 (35.5) 497 (34.3)
A106B 1250 (86.2) 1250 (86.2) 1250 (86.2) 1216 (83.9) 1182 (81.5) 1150 (79.3)
124
316SS 1250 (86.2) 1250 (86.2) 1120 (77.2) 1075 (74.1) 1030 (71.0) 992 (68.2)

*Consult the factory for pressure ratings of units with Monel trim.

Minimum Specific Gravity


For Monel Trim please consult factory.
Minimum Specific Gravity
(Dual Switch, anti-vibration, pneumatic or extra-high temperature)
Model
Standard w/ ET or FE Option
Series
316SS / 400SS All 316SS 316SS / 400SS All 316SS
“B” Trim “C” Trim “B” Trim “C” Trim
101 0.52 (0.64) 0.56 (0.67) 0.56 (0.67) 0.60 (0.71)
102 0.62 (0.73) 0.66 (0.77) 0.65 (0.76) 0.69 (0.80)
103 0.51 (0.57) 0.53 (0.59) 0.53 (0.59) 0.55 (0.61)
104 0.62 (0.68) 0.64 (0.70) 0.64 (0.70) 0.66 (0.72)
109 0.38 (0.41) 0.39 (0.42) 0.39 (0.42) 0.40 (0.43)
121 0.66 (0.87) 0.73 (0.94) 0.72 (0.93) 0.79 (1.01)
122 0.66 (0.87) 0.73 (0.94) 0.72 (0.94) 0.79 (1.01)
123 0.93 - 0.98 - 0.99 - 1.04 -
124 0.94 - 0.99 - 1.00 - 1.05 -

sorinc.com Form 912


913-888-2630 Registered Quality System to ISO 9001:2008 9/60
100 Series Step 2: Chamber Material
101 A-A1C-B-A1-N4-CRTT
Select chamber material from the following chart. Maximum working pressure in the chart on page 9
is based on the material selected here. Consult the factory for alternative materials.

Designator Material
A A106 Grade B Carbon Steel with A105 and A234-WPB fittings
C A312-TP316/316L Stainless Steel with A182-316/316L and A403-316/316L fittings

Step 3: Process Connection


101 A-A1C-B-A1-N4-CRTT

Select a process connection size, style and designator from the chart below. Consult the factory for
variations. Flanged process connections may reduce the maximum working pressure of the unit.

NPT Socket Flange


Size Style
Thread Weld 150# 300# 600#
VH A1A A1B A1C A1D A1E VH VV
(Vertical/Horizontal) (Vertical/Vertical)
VV - - B1C B1D B1E
1”
VVD C1A C1B C1C C1D C1E
VVT - - D1C D1D D1E
VH A5A A5B A5C A5D A5E
VV - - B5C B5D B5E
1-1/2”
VVD C5A C5B C5C C5D C5E VVD VVT
VVT - - D5C D5D D5E (Vertical/Vertical/ (Vertical/Vertical/
Drain) Tee Drain)
VH A2A* A2B* A2C A2D A2E
VV - - B2C B2D B2E
2”
VVD C2A* C2B* C2C C2D C2E
VVT - - D2C D2D D2E

*Not available on Models 121 and 122.

Step 4: Trim Material


Select the internal trim material from the chart below. 101 A-A1C-B-A1-N4-CRTT
Consult the factory for pressure ratings on Monel trim.

Available with
Designator Float Material Attraction Sleeve
Chamber Material:

B 316/316L Stainless Steel 400 Stainless Steel A106 Carbon Steel (A) only

A106 Carbon Steel (A) or


C 316/316L Stainless Steel 316/316L Stainless Steel
316/316L Stainless Steel (C)
A106 Carbon Steel (A) or
M Monel 400 Monel 400
316/316L Stainless Steel (C)

Form 912 sorinc.com


10/60 Registered Quality System to ISO 9001:2008 913-888-2630
100 Series Calibration Dimensions

The charts below provide typical standard Set Points. As the specific gravity used on a level switch
changes, the Set Points will also change. These values are based on the specific gravity listed
and units with “B” trim and an A1 switch. For other materials or switches, please consult factory.
If a specific Set Point is needed, please use the “SC” option found in the accessories section of
this catalog.

Model 101 Model 102


Specific Specific
“B” “C” “B” “C”
Gravity Gravity
.52 3-1/4” 4-7/16” .62 2-3/4” 3-13/16”
1.0 5-1/4” 5-15/16” 1.0 4-7/16” 5-1/8”

Model 103 Model 104


Specific Specific
“B” “C” “B” “C”
Gravity Gravity
.51 3-1/4” 3-7/8” .62 3-3/8” 3-15/16”
1.0 4-13/16” 5-3/16” 1.0 4-5/8” 5”

Model 109 Model 121


Specific Specific
“B” “C” “B” “C”
Gravity Gravity
.38 4-3/4” 5-15/16” .66 2-11/16” 4-1/8”
1.0 7-1/4” 7-9/16” 1.0 3-13/16” 4-13/16”

Model 122 Model 123


Specific Specific
“B” “C” “B” “C”
Gravity Gravity
.66 2-1/2” 3-15/16” .93 2-7/8” 3-13/16”
1.0 3-5/8” 4-5/8” 1.0 3-3/16” 4-1/16”

Model 124
Specific
“B” “C”
Gravity
.94 2-7/8” 3-13/16”
1.0 3-1/8” 4”

sorinc.com Form 912


913-888-2630 Registered Quality System to ISO 9001:2008 11/60
100 Series Chamber Dimensions
DRAWING NU

Dimensions listed are for reference only and are expressed


MODEL #
as millimeters over inches. (Linear = mm/in.)
DRAWING NUMBER SALES ORDER
They are subject to change without notice. Contact
PURCHASE ORDER # certified drawings of particular models or if
SOR for 0390019
MODEL # SALES ORDER #
special
PURCHASE ORDER #
dimensions are required. LINE ITEM #

14
180.9 * MINIMUM
180.9 146.1 5.7
* MINIMUM OVERHEAD CLEARANCE 7.12 REQUIRED TO
7.12 5.75
101.6 REQUIRED TO REMOVE HOUSING COVER.
101.6
4.00 4.00

THIS DRAWING WAS CREATED USIN


W *228.6 *228.6 THE VERTICAL_MOUNT_ASSY AND
9.00 W 9.00 FILE 0390019.txt LOCATED ON THE
K:\$Engineering Services\Concept tex
L L THEN THE DRAWING WAS CHANGE
W
DRAFT ENTITIES.
W 14

14685 W 105TH ST LENEXA, KS 66215 USA ISO-9001


913-888-2630
ISO-9001 SORINC.COM
DRAWN BY PRODUCT CER
M SMITH ALL DIMEN
PRODUCT CERTIFICATION DRAWING UNLESS OT
D ALL DIMENSIONS ARE ±1/16 IN
CHECKED BY

J REHM LIN
H UNLESS OTHERWISE SPECIFIED G
ENGINEER APPROVAL
MM
LINEAR = J FIFE
IN
DATE
THIS DRAW
3/14/11 NO USE WHA
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR. HEREON, NOR
NO USE WHATSOEVER OF THE INFORMATION CONTAINED MADE WITHOU
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE TITLE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
DIM DWG 100 S
E 1" SW
TITLE
EXTERNAL CHAM
DIMONLY)
(VVT DWG 100 SERIES SERVICEABLE
EXTERNAL CHAMBER VH STYLE EO NUMBER: 5
F F
DRAWING NUMBER REV
EO NUMBER: 5090 SCALE: DRAWIN
0390019 3 DRAWING
DO NOT NUMBE
SCALE
SCALE: DRAWING SCALE
Drawing 0390019 Drawing 0390021
DWG SIZE
Model Name: MODEL NAME.DRAFT/3/0+ SHEET 1 OF 1
DO NOT SCALE PRINT A
MODEL # SALES ORDER #
Model Name: MODEL NAME.DRAFT/3/1+
PURCHASE ORDER #

180.9
7.12 146.1
* MINIMUM
5.75
101.6
REQUIRED TO RE
Housing** W 4.00

General Purpose N4
Explosion Proof N7 W *228.6
1” NPT
Explosion Proof B1 9.00
Explosion Proof B2 L
Pneumatic P1 (3) 1/4” NPT W

ATEX T6
Flame Proof S3 w/CL 14685
M20 x 1.5***
SAA S3 ISO-9001

Flame Proof S8 PRODUCT CERTIF


355.6 ALL DIMENSIO
14.00 UNLESS OTHE
LINEA

* Minimum 5-3/4’’ (146 mm) overhead THIS DRAWIN

clearance required to remove housing cover.


NO USE WHATSO
I HEREON, NOR RE
MADE WITHOUT T
** See Housing section (page 48). TITLE

*** M20 adapters are brass. Contact the factory DRAIN CONN
DIM DWG 100 SER
EXTERNAL CHAMB
1"NPT OR SW E
for alternate materials. EO NUMBER: 5090
F SCALE: DRAWING
DO NOT SCALE PRINT

Note: All process flange nipples are 1” standard.


Model Name: MODEL NAME.DRAFT/3/0+
Drawing 0390010

Form 912 sorinc.com


12/60 Registered Quality System to ISO 9001:2008 913-888-2630
100 Series Chamber Dimensions

1” Connection
D1, 2 E1, 2 F4 G H4 I2 L2
Model
inch mm inch mm inch mm inch mm inch mm inch mm inch mm
101 16-5/8 422
10-1/2 267 3-3/4 95 6-1/2 165 14 356 14 356 3-3/4 95
102 17-5/16 440
103 18 457
10-1/4 260 4-13/16 122 7-7/16 189 14 356 14 356 4-9/16 116
104 19-3/4 502
109 12-5/8 321 5-13/16 148 8-7/16 214 16 406 16 406 7-1/2 191 17-13/16 452
121 16-3/8 416
9 229 3-1/4 83 6 152 14 356 14 356 3-3/4 95
122 16-15/16 430
123 17-5/16 440
10-1/2 267 3-3/4 95 6-1/2 165 14 356 14 356 3-3/4 95
124 18-3/4 476

1-1/2” Connection
D1, 2 E1, 2 F4 G H4 I2 L2
Model
inch mm inch mm inch mm inch mm inch mm inch mm inch mm
101 16-5/8 422
10-1/2 267 4 102 6-1/2 165 14 356 14 356 3-3/4 95
102 17-5/16 440
103 18 457
10-1/4 260 5-1/16 129 7-7/16 189 14 356 14 356 4-9/16 116
104 19-3/4 502
109 13-1/16 332 6-1/16 154 8-7/16 214 16 406 16 406 7-1/2 191 17-13/16 452
121 16-3/8 416
9 229 3-1/2 89 6 152 14 356 14 356 3-3/4 95
122 16-15/16 430
123 17-5/16 440
10-1/2 267 4 102 6-1/2 165 14 356 14 356 3-3/4 95
124 18-3/4 476

2” Connection
D1, 2 E1, 2 F4 G H4 I2, 3 L2, 3
Model
inch mm inch mm inch mm inch mm inch mm inch mm inch mm
101 17-5/8 448
10-1/2 267 4-5/16 110 6-1/2 165 14 356 14 356 4-3/4 121
102 18-5/16 467
103 19 483
10-1/4 260 5-3/8 137 7-7/16 189 14 356 14 356 4-9/16 116
104 20-3/4 527
109 13-3/8 340 6-3/8 162 8-7/16 214 16 406 16 406 8-1/2 216 18-13/16 478
121 16-3/85 4165
- - - - 6 152 14 356 14 356 3-3/45 955
122 16-15/165 4305
123 18-5/16 465
10-1/2 267 4-5/16 110 6-1/2 165 14 356 14 356 4-3/4 121
124 19-3/4 502

Notes
1. Dimensions D and E apply to socket-weld connections only. Consult factory for NPT dimensions.
2. Consult factory for dimensions for materials other than carbon steel.
3. Applies to socket weld or NPT process connections only.
4. Consult the factory if weld neck process flanges are required. Dimensions may vary from those shown above.
5. Applies to flanged process connections only.

sorinc.com Form 912


913-888-2630 Registered Quality System to ISO 9001:2008 13/60
200 Series Step 1: Model Series
201 A-A1C-B-A1-N4-CRTT

The 200 Series mechanical level switch is float operated with a sealed, tamper-proof external
chamber. Select the sensing unit from the following charts. Then refer to pages 44 - 50 for switching
elements, housings and accessories.
Select a model series from the charts below based on maximum operating pressure and minimum
specific gravity.
Model Chamber Pressure at Listed Temperature in psig (bar)*
Maximum
Series Material Working
100°F (38°C) Pressure
200°F (93°C) 300°F (149°C) 350°F (177°C) 400°F (204°C) 450°F (232°C)
See pageA106B
53 for pressure ratings at higher temperatures.
201 225 (15.5) 225 (15.5) 225 (15.5) 219 (15.1) 213 (14.7) 207 (14.3)
316SS
A106B
202 300 (20.7) 300 (20.7) 300 (20.7) 292 (20.1) 284 (19.5) 276 (19.0)
316SS
A106B
203 500 (34.5) 500 (34.5) 500 (34.5) 486 (33.5) 473 (32.6) 460 (31.7)
316SS
A106B 1250 (86.2) 1216 (83.9) 1182 (81.5) 1150 (79.3)
204 1250 (86.2) 1250 (86.2)
316SS 1187 (81.9) 1139 (78.6) 1091 (75.2) 1052 (72.6)
A106B
205 750 (51.7) 750 (51.7) 750 (51.7) 729 (50.3) 709 (48.9) 690 (47.6)
316SS
A106B 1000 (68.9) 973 (67.1) 946 (65.2) 920 (63.4)
206 1000 (68.9) 1000 (68.9)
316SS 945 (65.2) 907 (62.6) 869 (59.9) 838 (57.8
A106B 1000 (68.9) 973 (67.1) 946 (65.2) 920 (63.4)
207 1000 (68.9) 1000 (68.9)
316SS 945 (65.2) 907 (62.6) 869 (59.9) 838 (57.8
A106B
209 450 (31.0) 450 (31.0) 450 (31.0) 438 (30.2) 426 (29.4) 414 (28.6)
316SS
A106B
221 350 (24.1) 350 (24.1) 350 (24.1) 340 (23.4) 331 (22.8) 322 (22.2)
316SS

*Consult the factory for pressure ratings of units with Monel trim.

Minimum Specific Gravity


For Monel Trim please consult factory.
Minimum Specific Gravity
(Dual Switch, anti-vibration, pneumatic or extra-high temperature)
Model Series Standard w/ ET or FE Option
316SS / 400SS “B” All 316SS 316SS / 400SS “B” All 316SS
Trim “C” Trim Trim “C” Trim
201 0.38 (0.44) 0.40 (0.46) 0.40 (0.44) 0.42 (0.48)
202 0.52 (0.63) 0.55 (0.67) 0.55 (0.66) 0.59 (0.70)
203 0.61 (0.72) 0.65 (0.76) 0.64 (0.75) 0.68 (0.79)
204 0.91 - 0.96 - 0.98 - 1.03 -
205 0.50 (0.56) 0.52 (0.58) 0.52 (0.58) 0.54 (0.60)
206 0.65 (0.75) 0.68 (0.79) 0.68 (0.79) 0.71 (0.82)
207 0.61 (0.67) 0.63 (0.69) 0.63 (0.69) 0.65 (0.71)
209 0.38 (0.41) 0.39 (0.42) 0.39 (0.42) 0.40 (0.43)
221 0.64 (0.86) 0.72 (0.93) 0.71 (0.92) 0.78 (0.99)

Form 912 sorinc.com


14/60 Registered Quality System to ISO 9001:2008 913-888-2630
200 Series Step 2: Chamber Material
201 A-A1C-B-A1-N4-CRTT
Select chamber material from the following chart. Maximum working pressure in the chart on
this page is based on the material selected here. Consult the factory for alternative materials.

Designator Material
A A106 Grade B Carbon Steel with A105 and A234-WPB fittings
C A312-TP316/316L Stainless Steel with A182-316/316L and A403-316/316L fittings

Step 3: Process Connection


201 A-A1C-B-A1-N4-CRTT
Select a process connection, size, style and rating from the chart below. Consult the factory for
variations. Flanged process connections may reduce the maximum working pressure of the unit.

NPT Socket Flange


Size Style
Thread Weld 150# 300# 600# VH VV
VH A1A A1B A1C A1D A1E (Vertical/Horizontal) (Vertical/Vertical)

VV - - B1C B1D B1E


1”
VVD C1A C1B C1C C1D C1E
VVT - - D1C D1D D1E
VH A5A A5B A5C A5D A5E
VV - - B5C B5D B5E
1-1/2” VVD VVT
VVD C5A C5B C5C C5D C5E (Vertical/Vertical/ (Vertical/Vertical/
VVT - - D5C D5D D5E Drain) Tee Drain)
VH A2A* A2B* A2C A2D A2E
VV - - B2C B2D B2E
2”
VVD C2A* C2B* C2C C2D C2E
VVT - - D2C D2D D2E

*Not available on Model 221.

Step 4: Trim Material


201 A-A1C-B-A1-N4-CRTT
Select the internal trim material from the chart below. Consult the factory for pressure ratings
on Monel trim.
Available with
Designator Float Material Attraction Sleeve
Chamber Material:

B 316/316L Stainless Steel 400 Stainless Steel A106 Carbon Steel (A) only

A106 Carbon Steel (A) or


C 316/316L Stainless Steel 316/316L Stainless Steel
316/316L Stainless Steel (C)
A106 Carbon Steel (A) or
M Monel 400 Monel 400
316/316L Stainless Steel (C)
sorinc.com Form 912
913-888-2630 Registered Quality System to ISO 9001:2008 15/60
200 Series Calibration Dimensions
The charts below provide typical standard Set Points. As the specific gravity used on
a level switch changes, the Set Points will also change. These values are based on the
High
specific gravity listed and units with “B” trim and an A1 switch. For other materials or Level

switches, please consult factory. If a specific Set Point is needed, please use the “SC” Low
Level

option found in the accessories section of this catalog.

Model 201 Model 202 Model 203


Specific Gravity “B” “C” Specific Gravity “B” “C” Specific Gravity “B” “C”
.38 3-3/16” 4” .52 3-1/4” 4-7/16” .61 3” 4-1/16”
1.0 5-3/16” 5-9/16” 1.0 5-1/4” 5-16/16” 1.0 4-3/4” 5-7/16”

Model 204 Model 205 Model 206


Specific Gravity “B” “C” Specific Gravity “B” “C” Specific Gravity “B” “C”
.91 3” 3-15/16” .50 3” 3-11/16” .65 3-1/2” 4-1/4”
1.0 3-3/8” 4-1/4” 1.0 4-11/16” 5” 1.0 4-5/8” 5-1/16”

Model 207 Model 209 Model 221


Specific Gravity “B” “C” Specific Gravity “B” “C” Specific Gravity “B” “C”
.61 3” 3-9/16” .38 4-3/4” 5-1/4” .64 2-9/16” 4-1/16”
1.0 4-5/16” 4-5/8” 1.0 7-1/4” 7-1/2” 1.0 3-13/16” 4-13/16”

Chamber Dimensions DRAWING NUMBER

0390660
MODEL # SALES ORDER #
PURCHASE ORDER #
Dimensions listed are for reference only and are expressed as millimeters over inches. (Linear = mm/in.)
LINE ITEM # 0390661
They are subject DRAWING NUMBER

to change without notice. Contact SOR


MODEL # for certified
* MINIMUM
146.1 drawings of particular models or if special
OVERHEAD CLEARANCE
SALES ORDER #dimensions are required.
DRAWING N
PURCHASE ORDER # 5.75 LINE ITEM #

180.9 REQUIRED TO REMOVE HOUSING COVER.


MODEL # SALES ORDER
7.12
180.9 PURCHASE ORDER # 146.1
101.6 * MINIMUM OVERHEAD CLEARANCE
4.00 7.12DRAWING WAS CREATED 5.75
THIS USING
REQUIRED TO REMOVE HOUSING COVER.
101.6 THE VERTICAL_MOUNT_ASSY AND TEXT 180.9 1
4.00 FILE 0390660.txt LOCATED ON THE * MINIMUM
7.12 5
*228.6 K:\$Engineering Services\Concept text files REQUIRED TO
9.00 THEN THE DRAWING WAS CHANGED TO 101.6 THIS DRAWING WAS CREATED U
W 4.00
DRAFT ENTITIES. THE VERTICAL_MOUNT_ASSY AN
L *228.6 FILE 0390661.txt LOCATED ON
W 9.00
K:\$Engineering Services\Concept
W L
*228.6 THEN THE DRAWING WAS CHAN
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630 9.00 DRAFT ENTITIES.
ISO-9001 SORINC.COM W W
DRAWN BY
L
M SMITH 14685 W 105TH ST LENEXA, KS 66215 USA
PRODUCT CERTIFICATION DRAWING 913-888-2630
D ALL DIMENSIONS ARE ±1/16 IN
CHECKED BY
ISO-9001 SORINC.COM W
J REHM
H UNLESS OTHERWISE SPECIFIED ENGINEER APPROVAL DRAWN BY
MM
LINEAR = J FIFE M SMITH 1
IN PRODUCT CERTIFICATION DRAWING
DATE CHECKED BY
ALL DIMENSIONS ARE ±1/16 IN
G 3/15/11 UNLESS OTHERWISE SPECIFIED
J REHM
ISO-900
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR. ENGINEER APPROVAL
MM
NO USE WHATSOEVER OF THE INFORMATION CONTAINED LINEAR = J FIFE
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE IN
DATE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
355.6 3/15/11 PRODUCT CE
ALL DIMEN
E Drawing 14.00
TITLE

DIM DWG 200 SERIES SEALED CHAMBER THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR. UNLESS O
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
VH L
0390660
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
F DRAWING NUMBER REV MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
EO1" SW 5090
NUMBER:
(VVTSCALE:
ONLY)DRAWING SCALE
0390660
Drawing 2
DWG SIZE
TITLE

DIM DWG 200 SERIES SEALED CHAMBER


F SHEET 1 OF 1 THIS DRA

Model Name: MODEL NAME.DRAFT/2/0+


DO NOT SCALE PRINT
0390661
A VV, VVT
EO NUMBER: 5090 DRAWING NUMBER I REV
NO USE WH
HEREON, NO
MADE WITHO
Reset Form 0390661 2
SCALE: DRAWING SCALE DWG SIZE
TITLE

SHEET 1 OF 1 DIM DWG 200


DO NOT SCALE PRINT A
VVD
Model Name: MODEL NAME.DRAFT/1/4+ DRAIN CONN E
Housing** W 1"NPT OR SW Drawing
Reset Form EO NUMBER:
F SCALE: DRAW
General Purpose N4 0390662 DO NOT SCALE

Explosion Proof N7
Model Name: MODEL NAME.DRAFT/1/3+

1” NPT
Explosion Proof B1
Explosion Proof B2
Note: All process flange nipples are 1” standard.
Pneumatic P1 (3) 1/4” NPT
ATEX T6 * Minimum 5-3/4’’ (146 mm) overhead clearance required to remove
Flame Proof S3 w/CL housing cover. (Linear = mm/in.)
M20 x 1.5*** ** See Housing section (page 48).
SAA S3
Flame Proof S8
*** M20 adapters are brass. Contact the factory for alternate materials.

Form 912 sorinc.com


16/60 Registered Quality System to ISO 9001:2008 913-888-2630
200 Series Chamber Dimensions

1” Connections
D1, 2 E1, 2 F4 G H4 I1, 2 L2
Model
inch mm inch mm inch mm inch mm inch mm inch mm inch mm
201 10-1/4 260 4-13/16 122 7-7/16 189 14 356 14 356 4-9/16 116 15-3/16 386
202
203 10-1/2 267 3-3/4 95 6-1/2 165 14 356 14 356 3-3/4 95 14-3/8 365
204
205
206 10-1/4 260 4-13/16 122 7-7/16 189 14 356 14 356 4-9/16 116 15-3/16 386
207
209 12-5/8 321 5-13/16 148 8-7/16 214 16 406 16 406 7-1/2 191 18-1/16 459
221 9 229 3-1/4 83 6 152 14 356 14 356 3-3/4 95 14-3/8 365

1-1/2” Connections
D2 E2 F4 G H4 I2 L2
Model
inch mm inch mm inch mm inch mm inch mm inch mm inch mm
201 10-1/4 260 4-13/16 122 7-7/16 189 14 356 14 356 4-9/16 116 15-3/16 386
202
203 10-1/2 267 4 102 6-1/2 165 14 356 14 356 3-3/4 95 14-3/8 365
204
205
206 10-1/4 260 5-1/16 129 7-7/16 189 14 356 14 356 4-9/16 116 15-3/16 386
207
209 13-1/16 332 6-1/16 154 8-7/16 214 16 406 16 406 7-1/2 191 18-1/16 459
221 9 229 3-1/2 89 6 152 14 356 14 356 3-3/4 95 14-3/8 365

2” Connections
D2 E2 F4 G H4 I2, 3 L2, 3
Model
inch mm inch mm inch mm inch mm inch mm inch mm inch mm
201 10-1/4 260 5-3/8 137 7-7/16 189 14 356 14 356 5-9/16 141 16-3/16 411
202
203 10-1/2 267 4-5/16 110 6-1/2 165 14 356 14 356 4-3/4 121 15-3/8 391
204
205
206 10-1/4 260 5-3/8 137 7-7/16 189 14 356 14 356 5-9/16 141 16-3/16 411
207
209 13-3/8 340 6-3/16 162 8-7/16 214 16 406 16 406 7-1/2 191 19-1/16 484
5 5
221 - - - - 6 152 14 356 14 356 3-3/4 95 14-3/8 365

Notes
1. Dimensions D and E apply to socket-weld connections only. Consult factory for NPT dimensions.
2. Consult factory for dimensions for materials other than carbon steel.
3. Applies to socket weld or NPT process connections only.
4. Consult the factory if weld neck process flanges are required. Dimensions may vary from those shown above.
5. Applies to flanged process connections only.

sorinc.com Form 912


913-888-2630 Registered Quality System to ISO 9001:2008 17/60
108/208 Series Step 1: Model Series
108 A-E1A-F-A1-N4-CRTT
The 108/208 Series mechanical level switches are float operated, horizontal mounted with sealed,
tamper-proof or flanged, serviceable chambers. Select the sensing unit from the following charts.
Then refer to pages 44 - 50 for switching elements, housings and accessories.
Select a model series from the charts below based on maximum operating pressure and minimum
specific gravity. See page 52 for pressure ratings at higher temperatures.

Model Chamber Pressure at Listed Temperature in psid (bar)


Series Material 100°F (38 C) 200°F (93°C) 300°F (149°C) 350°F (177°C) 400°F (204°C) 450°F (232°C)
A106B 740 (51.0) 675 (46.5) 655 (45.1) 645 (44.4) 635 (43.7) 622 (42.8)
108
316SS 720 (49.6) 620 (42.7) 560 (38.6) 537 (37.0) 515 (35.5) 497 (34.2)
A106B 1857 (128.0) 1857 (128.0) 1857 (128.0) 1857 (128.0) 1857 (128.0) 1857 (128.0)
208
316SS 2248 (155.0) 1937 (133.5) 1746 (120.3) 1644 (133.4) 1602 (110.4) 1548 (106.7)

Minimum Specific Gravity


For all model series on this page, single switch only is equal to .65.
Consult the factory for units used with specific gravity lower than .65.

Step 2: Chamber Material


108 A-E1A-F-A1-N4-CRTT
Select chamber material from the following chart. Maximum working pressure in the chart above is
based on the material selected here. Consult the factory for alternative materials.
Designator Material
A A106 Grade B Carbon Steel with A105 and A234-WPB fittings
C A312-TP316/316L Stainless Steel with A182-316/316L and A403-316/316L fittings

Step 3: Process Connection


Select a process connection style and size from the chart 108 A-E1A-F-A1-N4-CRTT
below. Consult the factory for variations. NPT connections
not recommended above 900°F.
Size Style NPT Thread
E1A NPT
1”
E1B SW
E5A NPT
1-1/2”
E5B SW
E2A NPT
2”
E2B SW

Step 4: Trim Material


Select the internal trim material from the chart below. 108 A-E1A-F-A1-N4-CRTT
Available with
Designator Float Material Attraction Sleeve
Chamber Material:
F 321 Stainless Steel 400 Stainless Steel A106 Carbon Steel (A) only
A106 Carbon Steel (A) or
G 321 Stainless Steel 316/316L Stainless Steel
316/316L Stainless Steel (C)

Form 912 sorinc.com


18/60 Registered Quality System to ISO 9001:2008 913-888-2630
108/208 Series Chamber Dimensions DRAWIN

MODEL # SALES ORD


Dimensions listed are for reference only and are expressed as millimeters over inches. (Linear = mm/in.)
PURCHASE ORDER #0390667
DRAWING NUMBER

They# are subject to change without notice. Contact SOR for certified
MODEL SALES ORDERdrawings
# of particular models or if MODEL
CONN
S
special dimensions are required.
PURCHASE ORDER # LINE ITEM #
180.9
CONNECTION
MODEL A B C 7.12
SIZE 101.6 208A
1
180.9 125.4 250.8 399.0 4.00 (CS)
7.12 1"
4.94 9.88 15.71
101.6
4.00 108A 128.5 257.0 402.1
1-1/2" *228.6
(CS) 5.06 10.12 15.83
9.00
138.2 276.4 411.7 208C
2" 1
5.44 10.88 16.21 (316SST)
Model 108 *228.6 120.7 241.3 394.2 THIS DRAWING WAS CREATED
1"
9.00 Model 208 9.50
4.75 15.52
W
THE HORIZ_MOUNT_ASSY AN
108C
1-1/2"
130.3 260.6 403.9 FILE 0390667.txt LOCATED ON
(316SST) 5.13 10.26 15.90 K:\$Engineering
C Services\ConceISO-9
A
W 2" B
143.0 186.0 416.6 THEN THE DRAWING WAS CH
5.63 11.25 16.40 DRAFT ENTITIES. PRODUCT
ALL DIM
14685 W 105TH ST LENEXA, KS 66215 USA UNLESS
C 913-888-2630
A ISO-9001 SORINC.COM
317.5
B 164.3
DRAWN BY
187.3 THIS D
12.50 M SMITH NO USE W
6.47 DRAWING
PRODUCT CERTIFICATION 7.38
CHECKED BY HEREON,
ALL DIMENSIONS ARE ±1/16 IN 500.0 MADE WIT
J REHM
UNLESS OTHERWISE SPECIFIED 19.69
ENGINEER APPROVAL
TITLE

MM
Drawing 0390666
LINEAR =
IN J FIFE
DIM DWG 20
MOUNT FLO
DATE

3/16/11 146.1 EO NUMBER


Housing** * OVERHEAD
W CLEARANCE
Drawing 0390667 200.8 187.3 THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
5.75 SCALE: DRA
NO USE WHATSOEVER OF THE INFORMATION CONTAINED REQUIRED TO REMOVE COVER.
7.91 7.38 General Purpose N4
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
DO NOT SC

573.1 MADE
Model WITHOUT THE
Name: MODEL EXPRESS WRITTEN PERMISSION OF SOR.
NAME.DRAFT/2/0+

22.56 Explosion Proof N7


TITLE
1” NPT
Explosion
DIM DWG 108 Proof
SERIES HORIZONITAL B1
MOUNT FLOAT OPERATED
146.1 Explosion Proof B2
* Minimum 5-3/4”
*
5.75(146 mm) overhead clearance
OVERHEAD CLEARANCE EO NUMBER: 5090 DRAWING NUMBER

0390667
REV

2
required to remove housing
REQUIRED cover. COVER. SCALE:
TO REMOVE Pneumatic
DRAWING SCALE P1 DWG SIZE (3) 1/4” NPT
SHEET 1 OF 1
** See Housing section (page 48). DO NOT SCALE PRINT A
Model Name: MODEL NAME.DRAFT/2/0+
*** M20 adapters are brass. Contact the factory ATEX T6
for alternate materials. Flame Proof S3 w/CL
M20 x 1.5***
SAA S3
Flame Proof S8
1” Connections
A B C
Model
inch mm inch mm inch mm
108 4-13/16 1
122 1
9-5/8 2
244 2
15-1/2 394
208 4-15/16 125 9-7/8 250 15-5/8 396

1-1/2” Connections
A1 B1 C1
Model
inch mm inch mm inch mm
108 5-1/16 129 10-1/8 258 15-3/4 401
208 5-1/16 129 10-1/8 258 15-3/4 401

2” Connections
A1 B1 C1
Model
inch mm inch mm inch mm
108 5-3/8 137 10-3/4 274 16-1/8 409
208 5-3/8 137 10-3/4 274 16-1/8 409

Notes 1. Dimensions valid for socket weld process connections.


Consult factory for threaded connection dimensions.

sorinc.com Form 912


913-888-2630 Registered Quality System to ISO 9001:2008 19/60
300 Series Step 1: Model Series
301 A-F1A-B-A1-N4-CRTT

The 300 series mechanical level switches are float-operated switches suitable for top-insertion
mounting. Select the sensing unit from the following charts. Then refer to pages 44 - 50 for
switching elements, housings and accessories. Select a model series from the charts below based
on maximum operating pressure and minimum specific gravity.

Model Pressure at Listed Temperature in psid (bar)*


Series 100°F (38°C) 200°F (93°C) 300°F (149°C) 350°F (177°C) 400°F (204°C) 450°F (232°C)
301 225 (15.5) 225 (15.5) 225 (15.5) 219 (15.1) 213 (14.6) 207 (14.2)
303 500 (34.4) 500 (34.4) 500 (34.4) 486 (33.5) 473 (32.6) 460 (31.7)
304 750 (51.7) 750 (51.7) 750 (51.7) 729 (50.2) 709 (48.8) 690 (47.5)

*Consult the factory for pressure ratings of units with Monel trim.

Minimum Specific Gravity


Minimum specific gravity will be lower for shorter insertion depths. Consult the factory.
Minimum Specific Gravity Single Switch
(Dual Switch, anti-vibration, pneumatic or extra-high temperature)
Model Series Insertion Depth
316SS / 400SS
All 316SS Trim (C) All Monel Trim (M)
Trim (B)
24” .40 (.45) .42 (.48) .48 (.54)
301
48” .44 (.49) .46 (.52) .53 (.59)
24” .68 (.79) .72 (.84) .82 (.93)
303
48” .75 (.87) .80 (.91) .91 (1.02)
24” .52 (.58) .55 (.61) .62 (.68)
304
48” .56 (.62) .59 (.65) .67 (.73)
*An insertion depth must be supplied at time of order on all 300 Series switches.

Step 2: Process Connection Material


301 A-F1A-B-A1-N4-CRTT
Select process connection material from the following chart.

Designator Material
A A106 Carbon Steel
C A182-TP316/316L Stainless Steel

Form 912 sorinc.com


20/60 Registered Quality System to ISO 9001:2008 913-888-2630
300 Series Step 3: Process Connection
301 A-F1A-B-A1-N4-CRTT

Select a process connection, size and designator from the chart below. Consult the factory for
variations. Flanged process connections may reduce the maximum working pressure of the unit.

Select Designator
NPT Flange
Size
Thread 150# 300# 600#
1” F1A - - -
2” F2A - - -
3” F3A F3C F3D F3E
4” - F4C F4D F4E
6” - F6C F6D F6E

NPT Mounting Flange Mounting

Note: It is important to consider the installation configuration when selecting the process
connection. Be sure that the float will fit through the process connection, or that the vessel has
access to attach the float from inside the vessel after instrument installation. See page 26 for float
dimensions.

Step 4: Trim Material


301 A-F1A-B-A1-N4-CRTT
Select the internal trim material from the chart below. Consult the factory for pressure ratings on
Monel trim.

Available with
Designator Float Material Attraction Sleeve
Chamber Material:

B 316/316L Stainless Steel 400 Stainless Steel A106 Carbon Steel (A) only

A106 Carbon Steel (A) or


C 316/316L Stainless Steel 316/316L Stainless Steel
316/316L Stainless Steel (C)
A106 Carbon Steel (A) or
M Monel 400 Monel 400
316/316L Stainless Steel (C)

sorinc.com Form 912


913-888-2630 Registered Quality System to ISO 9001:2008 21/60
300 Series Unit Dimensions
Dimensions in this catalog are for reference only. They may be changed without notice. Contact the
factory for certified drawings for a particular model number. Dimensions are expressed as millimeters
over inches. (Linear = mm/in.)
MODEL # Standard UnitsSALES ORDER # LINE ITEM # PURCHASE ORDER #
SALES PAGE
Tandem Float Units
1

DIMENSION C INSERTION DEPTH A


FLANGE 180.9
SIZE 7.12 FLANGE B
150 # 300 # 600 #
101.6
62.7 67.6 70.6 4.00 DIMENSION C SEE CHART
3"
2.47 2.66 2.78
62.7 70.6 77.0 ELECTRICAL CONNECTION W
4"
2.47 2.78 3.03
64.3 75.4 86.6
6" 2 FLOAT SIZE MODEL
2.53 2.97 3.41
139.7
301
5.50
*227.0 88.9 152.4
X 303
8.94 3.50 6.00
139.7
304
5.50
146.1
* MINIMUM OVERHEAD CLEARANCE
5.75
W
REQUIRED TO REMOVE HOUSING COVER

C PROCESS
CONNECTION
FLANGE B

14685 W 105TH ST LENEXA, KS 66215 USA


913-888-2630
A ISO-9001 SORINC.COM
DRAWN BY

K MITCHELL
PRODUCT CERTIFICATION DRAWING
FLOAT ALL DIMENSIONS ARE ±1/16 IN
CHECKED BY

M SMITH
UNLESS OTHERWISE SPECIFIED ENGINEER APPROVAL
MM
LINEAR = J FIFE
IN
DATE

17 JUN 2011
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
NOTES: HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.

Drawing 1. FLOAT SIZE IS BASED ON MINIMUM DIFFERENTIAL SETTING,


Drawing
MINIMUM LIQUID SPECIFIC GRAVITY, AND SINGLE SWITCH FUNCTION.
TITLE

DIM DWG 300 SERIES FLANGED


FLOAT OPERATED

0390053 0390007
DRAWING NUMBER REV
2 2. CAUTION MUST BE USED IN SELECTING MOUNTING NOZZLE PIPE EO NUMBER: 5090
SCHEDULE TO PROVIDE FLOAT INSERTION CLEARANCE. SCALE: 0.33
DO NOT SCALE PRINT
0390007

SHEET 1 OF 1
3
DWG SIZE

B
Drawing
Model Name: 0390007.ASSEM/2/3+
Reset Form 0390665
Minimum 5-3/4’’ (146 mm) overhead clearance required to remove housing cover.
** See Housing section (page 48). ***M20 adapters are brass.
Contact the factory for alternate materials.
Housing** W Standard Units
General Purpose N4 Minimum Maximum
Explosion Proof N7
1” NPT Series Float Size Insertion Insertion
Explosion Proof B1
Explosion Proof B2 mm inch mm inch
303 3-1/2 x 6” 114 4-1/2
Pneumatic P1 (3) 1/4” NPT
301 1219 48
ATEX T6 5-1/2” 108 4-1/4
304
Flame Proof S3 w/CL
M20 x 1.5***
SAA S3
Flame Proof S8

Tandem Float Units


High Insertion Low Insertion Differential
Series Float Size Minimum Maximum Minimum Maximum Minimum Maximum
mm inch mm inch mm inch mm inch mm inch mm inch
303 3-1/2 x 6” 114 4-1/2 1016 40 305 12 1219 48 203 8 1105 43-1/2
301
5-1/2” 108 4-1/4 1041 41 279 11 1219 48 178 7 1111 43-3/4
304
Notes
1. Standard Units: It is important to consider the installation configuration when selecting the process
connection. Be sure that the float will fit through the process connection, or that the vessel has access to
attach the float from inside the vessel after instrument installation.
2. Tandem Float Units: It is important to consider the installation configuration when selecting the process
connection. Be sure that the float will fit through the process connection. Tandem floats are not removable
and must be installed through the nozzle opening. Operating specific gravity and insertion depths must be
specified.
Form 912 sorinc.com
22/60 Registered Quality System to ISO 9001:2008 913-888-2630
400 Series Step 1: Model Series
401 A-G3A-B-A1-N4-CRTT
The 400 Series mechanical level switch is float operated suitable for horizontal-insertion mounting.
Select the sensing unit from the following charts. Then refer to pages 44 - 50 for switching
elements, housings and accessories.
Select a model series from the charts below based on maximum operating pressure and minimum
specific gravity.

Maximum Working Pressure


Model Chamber Pressure at Listed Temperature in psig (bar)*
Series Material 100°F (38°C) 200°F (93°C) 300°F (149°C) 350°F (177°C) 400°F (204°C) 450°F (232°C)
A106B
401 230 (15.8) 230 (15.8) 230 (15.8) 224 (15.4) 218 (15.0) 212 (14.6)
316SS
A106B
402 350 (24.1) 350 (24.1) 350 (24.1) 340 (23.4) 331 (22.8) 322 (22.2)
316SS
A106B 230 (15.8) 215 (14.8) 200 (13.7) 185 (12.7)
403 230 (15.8) 230 (15.8)
316SS 215 (14.8) 205 (14.1) 195 (13.4) 182 (12.5)
A106B
404 500 (34.4) 500 (34.4) 500 (34.4) 486 (33.5) 473 (32.6) 460 (31.7)
316SS
A106B 740 (51.0) 675 (46.5) 655 (46.1) 645 (44.4) 635 (43.7) 618 (42.6)
405
316SS 720 (49.6) 620 (42.7) 560 (38.6) 537 (37.0) 515 (35.5) 497 (34.2)
A106B 1250 (86.2) 1250 (86.2) 1216 (83.8) 1182 (81.5) 1150 (79.3)
406 1250 (86.2)
316SS 1240 (85.5) 1120 (77.2) 1075 (74.1) 1030 (71.0) 992 (68.4)

*Consult the factory for pressure ratings of units with Monel trim

Minimum Specific Gravity


Model Single Switch
401 .50
402 .90
403 .50
404 .60
405 .60
406 .60
Note: Insertion depth may affect minimum specific gravity.

Step 2: Chamber Material


401 A-G3A-B-A1-N4-CRTT
Select chamber material from the following chart. Maximum working pressure in the chart above is
based on the material selected here. Consult the factory for alternative materials.

Designator Material
A A106 Grade B Carbon Steel with A105 and A234-WPB fittings
C A312-TP316/316L Stainless Steel with A182-316/316L and A403-316/316L fittings

sorinc.com Form 912


913-888-2630 Registered Quality System to ISO 9001:2008 23/60
400 Series Step 3: Process Connection
401 A-G3A-B-A1-N4-CRTT
Select a process connection designator from the chart below based on style and size. Consult the factory for
variations. 3” flanged process connections may require the float to be installed from inside the process connection.
Float Connection Float Connection
Model Model
Size Designator Size Style Size Designator Size Style
NPT(M) 300# RF
401 3” G3A 3” 405 3 x 6” G3G 3” Weld Neck
Thread
Flange
NPT(M)
402 2-1/2” G7A 2-1/2” 300# RF
Thread
405 3 x 6” G4G 4” Weld Neck
150# RF Flange
403 3” G3F 3” Weld Neck
600# RF
Flange
406 3 x 6” G3H 3” Weld Neck
150# RF Flange
403 3” G4F 4” Weld Neck
600# RF
Flange
406 3 x 6” G4H 4” Weld Neck
NPT(M) Flange
404 3 x 6” G3A 3”
Thread
Step 4: Trim Material
401 A-G3A-B-A1-N4-CRTT
Select the internal trim material from the chart below. Consult the factory for pressure ratings on Monel trim.
Available with
Designator Float Material Attraction Sleeve
Chamber Material:
B 316/316L Stainless Steel 400 Stainless Steel A106 Carbon Steel (A) only
A106 Carbon Steel (A) or 316/316L
C 316/316L Stainless Steel 316/316L Stainless Steel
Stainless Steel (C)
A106 Carbon Steel (A) or 316/316L
M Monel 400 Monel 400
Stainless Steel (C)

Chamber Dimensions
Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory
for certified drawings for a particular model number. Dimensions are expressed as millimeters over inches.
(Linear = mm/in.)
Housing** W
General Purpose N4
Explosion Proof N7
Models 401, 402, 404 Models 403, 405, 406 Explosion Proof B1
1” NPT
Explosion Proof B2
Drawing Drawing
0390668 0390669 (3) 1/4”
MODEL # SALES ORDER # Pneumatic LINE ITEM # P1
PURCHASE ORDER #

NPT
217.5 N
8.56 1 MAXIMUM DIFFERENTIAL (D)
180.9
T6
FLANGED
NOZZLE LENGTH (N)
7.12
ATEX UNITS
101.6
S3
MODEL
51
2.0
102
4.0
152
6.0
203
8.0
254
10.0
4.00
Flame Proof M20229 x
w/CL
403
330
13.0 9.0
178
7.0
127
5.0
114
4.5
405** 1.5***
SAA S3
152 127
6.0 5.0
406**
*227.0
8.94 Flame Proof S8
**BASED ON 4" FLANGE SIZE

W CUSTOMER
STANDARD DIFFERENTIAL (D)
PROCESS
CONNECTION MODEL "D" @ MIN. S.G.
51
403
118.3 2.0
4.66 405
44.5

* Minimum 146.1 overhead clearance required to remove


1.75
406
D 1
5.75 housing cover. FLOAT 14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
SORINC.COM
ISO-9001

** See Housing section (page 48).


DRAWN BY

K MITCHELL
PROCESS PRODUCT CERTIFICATION DRAWING CHECKED BY
CONNECTION ALL DIMENSIONS ARE ±1/16 IN
J REHM
*** M20 adapters are brass. Contact the factory for alternate WELD NECK
FLANGE
UNLESS OTHERWISE SPECIFIED
LINEAR =
MM
IN
ENGINEER APPROVAL

J FIFE
DATE

materials. 263.5
457
18.0
08 APR 2011
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
10.38 NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE

Form 912 * MINIMUM


146.1
5.75
OVERHEAD CLEARANCE sorinc.com DIM DWG 403,405,406
FLOAT OPERATED
REQUIRED TO REMOVE HOUSING COVER. NOTES: EO NUMBER: 5090 DRAWING NUMBER REV

Registered Quality ELECTRICAL


System CONN. "W" : to ISO 9001:20081 913-888-2630
0390669 2

24/60 __________
Model Name: 0390669.ASSEM/1/5+
1. STANDARD DIFFERENTIAL. FOR MAXIMUM DIFFERENTIAL, SEE TABLE. SCALE: 0.33
DO NOT SCALE PRINT
SHEET 1 OF 1
DWG SIZE

Reset Form
400 Series Calibration Dimensions

Standard Differential (D)


Model “D” @ Minimum Specific Gravity
Note: With anti-vibration, extra-high
temperature and pneumatic switch,
401 minimum differential will increase.
402
3” (76 mm)
403
404
405
2-3/4” (70 mm)
406

Maximum Differential (D)


Differential Dimension “D” is calibrated to the minimum shown above as standard. Wider
differentials are available by placing an SC in the accessory section of the model number.
The charts below give the maximum differentials available.

NPT Units
Customer Mounting
Model
1/2 Coupling Full Coupling
401 12-3/8” (356 mm) 10-1/4” (292 mm)
402 8-7/8” (292 mm) 8-7/8” (292 mm)
404 12-3/8” (356 mm) 10-1/4” (292 mm)

Flanged Units
Customer Nozzle Length (N)
Model
2” (51 mm) 4” (102 mm) 6” (152 mm) 8” (203 mm) 10” (254 mm)
403 13” (330 mm) 9” (229 mm) 7” (178 mm) 5” (127 mm) 4-1/2” (114 mm)
405*
6” (152 mm) 5” (127 mm)
406*
*Based on 4-inch flange size.

sorinc.com Form 912


913-888-2630 Registered Quality System to ISO 9001:2008 25/60
741-743, 801
and 802 Series Step 1: Model Series
741 A-A1C -B-A1-N4-CRTT

The 741-743, 801 and 802 Series mechanical level switches are displacer-operated with flanged,
serviceable external chambers. Select the sensing unit from the following charts. Then refer to
pages 44 - 50 for switching elements, housings and accessories.
Select a model series from the charts below based on maximum operating pressure and minimum
specific gravity.

Maximum Working Pressure


Model Chamber
Pressure at Listed Temperature in psig (bar)*
Series Material 100°F (38°C) 200°F (93°C) 300°F (149°C) 350°F (177°C) 400°F (204°C) 450°F (232°C)

A106B 285 (19.7) 260 (17.4) 230 (15.8) 215 (14.8) 200 (13.7) 185 (12.7)
741
316SS 275 (18.9) 240 (16.5) 215 (14.8) 205 (14.1) 195 (13.4) 182 (12.5)

A106B 740 (51.0) 680 (46.9) 655 (45.1) 645 (44.4) 635 (43.7) 618 (42.6)
742
316SS 720 (49.6) 620 (42.7) 560 (38.6) 537 (37.0) 515 (35.5) 497 (34.2)

A106B 1480 (102.0) 1294 (89.2) 1166 (80.4) 1118 (77.1) 1070 (73.8) 1034 (71.3)
743
316SS 1440 (99.3) 1240 (85.5) 1120 (77.2) 1075 (74.1) 1025 (70.7) 990 (68.3)

A106B 1435 (98.9) 1294 (89.2) 1166 (80.4) 1118 (77.1) 1070 (73.8) 1034 (68.3)
801
316SS 1440 (94.3) 1240 (85.5) 1120 (77.2) 1075 (74.1) 1025 (70.7) 990 (68.3)

A106B 3376 (232.8) 3019 (208.2) 2721 (187.6) 2609 (179.9) 2497 (172.2) 2414 (166.4)
802
316SS 3504 (241.6) 3019 (208.2) 2721 (187.6) 2609 (179.9) 2497 (172.2) 2414 (166.4)

*Consult the factory for pressure ratings of units with Monel trim. Standard displacer units are
not available above 450°F (232°C).

Minimum Specific Gravity


Model Anti-Vibration
Standard
Series or Pneumatic
741
742
0.43 0.57
743
801
802 0.41 0.5

Step 2: Chamber Material


741 A-A1C-B-A1-N4-CRTT
Select chamber material from the following chart. Maximum working pressure in the chart above is
based on the material selected here. Consult the factory for alternate materials.
Designator Material
A A106 Grade B Carbon Steel with A105 and A234-WPB fittings
C A312-TP316/316L Stainless Steel with A182-316/316L and A403-316/316L fittings

Form 912 sorinc.com


26/60 Registered Quality System to ISO 9001:2008 913-888-2630
741-743, 801
and 802 Series Step 3: Process Connection
741 A-A1C-B-A1-N4-CRTT

Select a process connection size, style and designator from the chart below. Consult the factory for
variations. Flanged process connections may reduce the maximum working pressure of the unit.
Flange
NPT Socket
Size Style 150# 300# 600# 1500#
Thread Weld VH VV
RF RF RF RTJ
(Vertical/Horizontal) (Vertical/Vertical)
VH A1A A1B A1C A1D A1E A1T
VV - - B1C B1D B1E B1T
1”
VVD C1A C1B C1C C1D C1E C1T
VVT - - D1C D1D D1E D1T
VH A5A A5B A5C A5D A5E A5T
VV - - B5C B5D B5E B5T VVD VVT
1-1/2” (Vertical/Vertical/ (Vertical/Vertical/
VVD C5A C5B C5C C5D C5E C5T Drain) Tee Drain)
VVT - - D5C D5D D5E D5T
VH A2A* A2B* A2C A2D A2E A2T
VV - - B2C B2D B2E B2T
2”
VVD C2A* C2B* C2C C2D C2E C2T
VVT - - D2C D2D D2E D2T
*Not available on Models 741, 742, and 743.

Step 4: Trim Material


741 A-A1C-B-A1-N4-CRTT
Select the internal trim material from the chart below. Consult the factory for pressure ratings on
Monel trim.
Available with
Designator Displacer Material Attraction Sleeve
Chamber Material:

B 316/316L Stainless Steel 400 Stainless Steel A106 Carbon Steel (A) only

A106 Carbon Steel (A) or


C 316/316L Stainless Steel 316/316L Stainless Steel
316/316L Stainless Steel (C)
A106 Carbon Steel (A) or
M Monel 400 Monel 400
316/316L Stainless Steel (C)

sorinc.com Form 912


913-888-2630 Registered Quality System to ISO 9001:2008 27/60
741-743, 801
and 802 Series Calibration Dimensions

The charts below provide typical standard Set Points. As the specific gravity used on a level switch
changes, the Set Points will also change. These values are based on the specific gravity listed
and units with “B” trim and an A1 switch. For other materials or switches, please consult factory.
If a specific Set Point is needed, please use the “SC” option found in the accessories section of
this catalog.

Model 741, 742, 743, 801 Model 802


Specific Specific
“B” “C” “B” “C”
Gravity Gravity
.43 1-13/16” 4-5/8” .41 2-3/8” 5-5/16”
1.0 4-9/16” 6-1/16” 1.0 5-1/16” 6-7/16”

Chamber Dimensions DRAWING NUMBER

Dimensions listed are for reference only and are expressed


MODEL as
# millimeters
0390019
over inches. (Linear = mm/in.)
DRAWING NUMBER
SALES ORDER #

MODEL # They are subject to change without notice. Contact SOR for certified drawings of particular models or if
PURCHASE ORDER #
SALES ORDER #

special dimensions are required.


PURCHASE ORDER # LINE ITEM #

146.1
180.9 * MINIMUM
180.9 146.1 5.75
* MINIMUM OVERHEAD CLEARANCE 7.12 REQUIRED TO REM
7.12 5.75
101.6 REQUIRED TO REMOVE HOUSING COVER. 101.6
4.00 4.00

THIS DRAWING WAS CREATED USING


W *228.6 THE *228.6
VERTICAL_MOUNT_ASSY AND TEXT
9.00 W 9.00
FILE 0390019.txt LOCATED ON THE
K:\$Engineering Services\Concept text files
L L
THEN THE DRAWING WAS CHANGED TO
W
DRAFT ENTITIES.
W 14685

14685 W 105TH ST LENEXA, KS 66215 USA ISO-9001


913-888-2630
ISO-9001 SORINC.COM
PRODUCT CERTIF
DRAWN BY
ALL DIMENSIO
M SMITH UNLESS OTHE
PRODUCT CERTIFICATION DRAWING
D ALL DIMENSIONS ARE ±1/16 IN
CHECKED BY
LINEA
J REHM G
H UNLESS OTHERWISE SPECIFIED ENGINEER APPROVAL
MM
LINEAR = J FIFE
IN
DATE THIS DRAWING
NO USE WHATSOE
3/14/11 HEREON, NOR REP
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR. MADE WITHOUT TH
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
TITLE
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR. DIM DWG 100 SERI
E TITLE 1" SW EXTERNAL CHAMBE
(VVT
DIM DWG 100 SERIES ONLY)
SERVICEABLE EO NUMBER: 5090
F Drawing 0390019 EXTERNAL CHAMBER VH STYLE F Drawing 0390021 DRAWING NUMBER

0390010
DRAWING NUMBER REV SCALE: DRAWING S
EO NUMBER: 5090 MODEL # SALES ORDER #
0390019 3 DO NOT SCALE PRINT
SCALE: DRAWING PURCHASE ORDER # LI
Model Name: SCALE
MODEL NAME.DRAFT/3/0+ DWG SIZE
SHEET 1 OF 1
DO NOT SCALE PRINT A 180.9
Model Name: MODEL NAME.DRAFT/3/1+ 7.12 146.1
* MINIMUM OVERHEA
5.75
101.6
REQUIRED TO REMOVE HOU
4.00

Note: All process flange nipples are 1” standard.


W *228.6
Housing** W 9.00

L
General Purpose N4
W
Explosion Proof N7
1” NPT
Explosion Proof B1
Explosion Proof B2 * Minimum 5-3/4’’ (146 mm) 14685 W 105TH ST
913
overhead clearance required ISO-9001 SOR

Pneumatic P1 (3) 1/4” NPT


to remove housing cover. PRODUCT CERTIFICATION DRA
355.6
** See Housing section. 14.00
ALL DIMENSIONS ARE ±1/1
UNLESS OTHERWISE SPECIF

(Page 48.) LINEAR =


MM
IN
ATEX T6 *** M20 adapters are brass.
Flame Proof S3 w/CL Contact the factory for
THIS DRAWING IS THE EXCLUSI
NO USE WHATSOEVER OF THE IN
I
M20 x 1.5*** HEREON, NOR REPRODUCTION IN
MADE WITHOUT THE EXPRESS WRI

SAA S3 alternate materials. TITLE

DIM DWG 100 SERIES SERVICEAB


DRAIN CONN
Flame Proof S8 1"NPT OR SW E EXTERNAL CHAMBER VVD STYLE

Drawing 0390010
DRAWING
EO NUMBER: 5090
F SCALE: DRAWING SCALE
SH
DO NOT SCALE PRINT

Form 912 Model Name: MODEL NAME.DRAFT/3/0+ sorinc.com


28/60 Registered Quality System to ISO 9001:2008 913-888-2630
741-743, 801
and 802 Series Chamber Dimensions

1” Connections
D1, 2 E1, 2 F4 G H4 I2 L2
Model
inch mm inch mm inch mm inch mm inch mm inch mm inch mm
741 19-5/16 491
742 13 330 3-1/4 83 6 152 16 406 16 406 3-3/4 95 19-1/2 495
743 19-7/8 505
801 11-1/2 292 3-3/4 95 3-3/4 95 20-1/4 514
8 203 16 406 16 406
802 12-3/4 324 3-7/8 98 6-3/4 171 20-3/4 527

1-1/2” Connections
D2 E2 F4 G H4 I2 L2
Model
inch mm inch mm inch mm inch mm inch mm inch mm inch mm
741 19-5/16 491
742 13 330 3-1/2 89 6 152 16 406 16 406 3-3/4 95 19-1/2 495
743 19-7/8 505
801 11-9/16 294 3-3/4 95 20-1/4 514
4 102 8 203 16 406 16 406
802 12-7/8 327 6-3/4 171 20-3/4 527

2” Connections
D2 E2 F4 G H4 I2, 3 L2, 3
Model
inch mm inch mm inch mm inch mm inch mm inch mm inch mm
741 19-5/165 4915
742 - - - - 6 152 16 406 16 406 3-3/45 955 19-1/25 4955
743 19-7/85 5055
801 11-11/16 297 4-3/4 121 21-1/4 540
4-5/16 110 8 203 16 406 16 406
802 13-3/16 335 7-3/4 197 21-5/16 541

Notes
1. Dimensions D and E apply to socket-weld connections only. Consult factory for NPT dimensions.
2. Consult factory for dimensions for materials other than carbon steel.
3. Applies to socket weld or NPT process connections only.
4. Consult the factory if weld neck process flanges are required. Dimensions may vary from those shown above.
5. Applies to flanged process connections only.

sorinc.com Form 912


913-888-2630 Registered Quality System to ISO 9001:2008 29/60
740, 803 and 804 Series Step 1: Model Series
740 A-A1C-B-A1-N4-CRTT

The 740, 803, and 804 Series mechanical level switches are displacer operated with sealed,
tamper-proof external chambers. Select the sensing unit from the following charts. Then refer to
pages 44 - 50 for switching elements, housings and accessories.
Select a model series from the charts below based on maximum operating pressure and minimum
specific gravity.

Maximum Working Pressure

Model Chamber Pressure at Listed Temperature in psig (bar)*


Series Material 100°F (38°C) 200°F (93°C) 300°F (149°C) 350°F (177°C) 400°F (204°C) 450°F (232°C)

A106B
740 1480 (102.0) 1294 (89.2) 1166 (80.4) 1118 (77.1) 1070 (73.8) 1034 (71.3)
316SS

A106B
803 1480 (102.0) 1294 (89.2) 1166 (80.4) 1118 (77.1) 1070 (73.8) 1034 (71.3)
316SS

A106B 3376 (232.8)


804 3019 (208.2) 2721 (187.6) 2609 (179.9) 2497 (172.2) 2414 (166.4)
316SS 3504 (241.6)

* Consult the factory for pressure ratings of units with Monel trim. Standard displacer units are not available
over 450oF (232oC).

Minimum Specific Gravity


Model Anti-Vibration
Standard
Series or Pneumatic
740
0.43 0.57
803
804 0.41 0.50

Step 2: Chamber Material


740 A-A1C-B-A1-N4-CRTT
Select chamber material from the following chart. Maximum working pressure in the chart above is
based on the material selected here. Consult the factory for alternative materials.

Designator Material
A A106 Grade B Carbon Steel with A105 and A234-WPB fittings
C A312-TP316/316L Stainless Steel with A182-316/316L and A403-316/316L fittings

Form 912 sorinc.com


30/60 Registered Quality System to ISO 9001:2008 913-888-2630
740, 803 and 804 Series Step 3: Process Connection
740 A-A1C-B-A1-N4-CRTT
Select a process connection size, style and designator from the chart below. Consult the factory for
variations. Flanged process connections may reduce the maximum working pressure of the unit.
Flange
NPT Socket VH VV
Size Style 150# 300# 600# 1500#
Thread Weld (Vertical/Horizontal) (Vertical/Vertical)
RF RF RF RTJ
VH A1A A1B A1C A1D A1E A1T
VV - - B1C B1D B1E B1T
1”
VVD C1A C1B C1C C1D C1E C1T
VVT - - D1C D1D D1E D1T
VH A5A A5B A5C A5D A5E A5T
VV - - B5C B5D B5E B5T VVD VVT
1-1/2” (Vertical/Vertical/ (Vertical/Vertical/
VVD C5A C5B C5C C5D C5E C5T
Drain) Tee Drain)
VVT - - D5C D5D D5E D5T
VH A2A* A2B* A2C A2D A2E A2T
VV - - B2C B2D B2E B2T
2”
VVD C2A* C2B* C2C C2D C2E C2T
VVT - - D2C D2D D2E D2T
*Not available on Model 740.
Step 4: Trim Material
740 A-A1C-B-A1-N4-CRTT
Select the internal trim material from the chart below. Consult the factory for pressure ratings
on Monel trim.
Available with
Designator Displacer Material Attraction Sleeve
Chamber Material:

B 316/316L Stainless Steel 400 Stainless Steel A106 Carbon Steel (A) only

A106 Carbon Steel (A) or


C 316/316L Stainless Steel 316/316L Stainless Steel
316/316L Stainless Steel (C)
A106 Carbon Steel (A) or
M Monel 400 Monel 400
316/316L Stainless Steel (C)

Calibration Dimensions
The charts below provide typical standard Set Points. As the specific gravity used on a level switch
changes, the Set Points will also change. These values are based on the specific gravity listed
and units with “B” trim and an A1 switch. For other materials or switches, please consult factory.
If a specific Set Point is needed, please use the “SC” option found
in the accessories section of this catalog.

Model 740, 803 Model 804


Specific Specific
“B” “C” “B” “C”
Gravity Gravity
.43 1-13/16” 4-5/8” .41 2-3/8” 5-5/16”
1.0 4-9/16” 6-1/16” 1.0 5-1/16” 6-7/16”

sorinc.com Form 912


913-888-2630 Registered Quality System to ISO 9001:2008 31/60
DRAWING NUMBER

0390661

740, 803 and 804 Series Chamber Dimensions


MODEL #
PURCHASE ORDER #
SALES ORDER #

Dimensions listed are for reference only and are expressed as millimeters 180.9
7.12
* MINIMUM
146.1
5.75
OVERH
REQUIRED TO REMOVE H
over inches. (Linear = mm/in.) They are subject to change without notice. 101.6
4.00

Contact SOR for certified drawings of particular models or if special


DRAWING NUMBER

0390660
MODEL # SALES ORDER #
dimensions are required. PURCHASE ORDER # W
*228.6
LINE ITEM # 9.00
L
146.1
* MINIMUM OVERHEAD CLEARANCE
5.75
W
REQUIRED TO REMOVE HOUSING COVER.
180.9
Housing** W 7.12
14685 W 105TH
9
ISO-9001
101.6
General Purpose N4 4.00 THIS DRAWING WAS CREAT
PRODUCT CERTIFICATION

Explosion Proof N7 G THE VERTICAL_MOUNT_AS


ALL DIMENSIONS ARE ±
UNLESS OTHERWISE SP
1” NPT FILE 0390660.txt LOCATED MM
Explosion Proof B1 *228.6
LINEAR =
K:\$Engineering Services\Co IN

Explosion Proof B2 W 9.00 THEN THE DRAWING WAS


THIS DRAWING IS THE EXC

L
DRAFT ENTITIES.
NO USE WHATSOEVER OF TH
HEREON, NOR REPRODUCTIO
DRAWING NUMBER
MADE WITHOUT THE EXPRESS
1" SW TITLE
0390662
MODEL #(VVT ONLY)
Pneumatic P1 (3) 1/4” NPT W PURCHASE ORDER #
F
SALES ORDER
DIM DWG
VV, VVT
200# SERIES SEALED
LIN
14685 W 105TH ST LENEXA, KS 66215 USA EO NUMBER: 5090 DRA

Drawing 0390661
913-888-2630
SORINC.COM
ISO-9001 180.9
SCALE: DRAWING
* MINIMUM
146.1 SCALE
OVERHEA
ATEX T6 Model Name: MODEL NAME.DRAFT/1/4+
DRAWN BY 7.12 5.75
DO NOT SCALE PRINT

REQUIRED TO REMOVE HOU


M101.6
SMITH
Flame Proof S3 w/CL D
PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
CHECKED BY
4.00
M20 x 1.5*** H UNLESS OTHERWISE SPECIFIED
J REHM
ENGINEER APPROVAL
MM
SAA S3 LINEAR =
IN J FIFE
*228.6
DATE

Flame Proof S8 W THIS DRAWING IS THE EXCLUSIVE LPROPERTY OF SOR.


3/15/11
9.00

NO USE WHATSOEVER OF THE INFORMATION CONTAINED


HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE

* Minimum 5-3/4’’ (146 mm) overhead


MADE WITHOUT THE EXPRESS WRITTEN PERMISSIONW OF SOR.
E TITLE

clearance required to remove housing cover. Drawing 0390660 DIM DWG 200 SERIES SEALED CHAMBER
VH
14685 W 105TH ST
913-
F
** See Housing section (page 48). DRAWING NUMBER REV ISO-9001 SOR
EO NUMBER: 5090
0390660 2
*** M20 adapters are brass. Contact the factory SCALE: DRAWING SCALE
DO NOT SCALE PRINT
355.6
SHEET
14.001 OF 1
DWG SIZE

A
PRODUCT CERTIFICATION DRA
ALL DIMENSIONS ARE ±1/1
UNLESS OTHERWISE SPECIF
for alternate materials. Model Name: MODEL NAME.DRAFT/2/0+ LINEAR =
MM
IN
Reset Form
THIS DRAWING IS THE EXCLUSI
NO USE WHATSOEVER OF THE INF
I HEREON, NOR REPRODUCTION IN
MADE WITHOUT THE EXPRESS WRIT
TITLE

Note: All process flange nipples are 1” standard.


DIM DWG 200 SERIES SEALED CH
VVD
DRAIN CONN
1"NPT OR SW
E
Drawing 0390662 EO NUMBER: 5090 DRAWING

1” Connection F SCALE: DRAWING SCALE


DO NOT SCALE PRINT
SH

Model Name: MODEL NAME.DRAFT/1/3+

D1, 2 E1, 2 F4 G H4 I2 L2
Model
inch mm inch mm inch mm inch mm inch mm inch mm inch mm
740 13 330 3-1/4 83 6 152 16 406 16 406 3-3/4 95 20-1/4 514
803 11-1/2 292 3-3/4 95 3-3/4 95 20-1/4 514
8 203 16 406 16 406
804 12-3/4 324 3-7/8 98 6-3/4 171 21-3/4 552

1-1/2” Connection
D2 E2 F4 G H4 I2 L2
Model
inch mm inch mm inch mm inch mm inch mm inch mm inch mm
740 13 330 3-1/2 89 6 152 16 406 16 406 3-3/4 95 20-1/4 514
803 11-9/16 294 4 102 3-3/4 95 20-1/4 514
8 203 16 406 16 406
804 12-7/8 327 4 102 6-3/4 171 21-3/4 552

2” Connection
D2 E2 F4 G H4 I2, 3 L2, 3
Model
inch mm inch mm inch mm inch mm inch mm inch mm inch mm
5 5 5
740 - - - - 6 152 16 406 16 406 3-3/4 95 20-1/4 5145
803 11-11/16 297 4-5/16 110 4-3/4 121 20-1/4 514
8 203 16 406 16 406
804 13-3/16 335 4-5/16 110 7-3/4 197 21-3/4 552
Notes
1. Dimensions D and E apply to socket-weld connections only. Consult factory for NPT dimensions.
2. Consult factory for dimensions for materials other than carbon steel.
3. Applies to socket weld or NPT process connections only.
4. Consult the factory if weld neck process flanges are required. Dimensions may vary from those shown above.
5. Applies to flanged process connections only.
Form 912 sorinc.com
32/60 Registered Quality System to ISO 9001:2008 913-888-2630
700 Series Step 1: Model Series
702 A-F7A-B-A1-N4-CRTT
The 700 Series mechanical level switches are single-stage, displacer-operated switches suitable
for top-insertion tank mounting. Select the sensing unit from the following charts. Then refer to
pages 44 - 50 for switching elements, housings and accessories.
Select a model series from the charts below based on maximum operating pressure and minimum
specific gravity. Minimum specific gravity is based on single switch. Anti-vibration and pneumatic
switches have higher minimum specific gravities.

Maximum Working Pressure


Minimum Pressure Rating - psig (bar)
Model Connection Displacer Connection
Specific Function
Series Style Material Material 100°F (38°C) 450°F (232°C)
Gravity
701 0.51 Porcelain All 1000 (69) 750 (52)
NPT
702 0.45 SS All 1000 (69) 750 (52)
Narrow A105 285 (20) 185 (13)
703 0.51 Flange Porcelain
Differential 316SS 275 (19) 182 (13)
A105 285 (20) 185 (13)
704 0.45 Flange SS
316SS 275 (19) 182 (13)
705 Porcelain All 1000 (69) 750 (52)
NPT
706 SS All 1000 (69) 750 (52)
Wide A105 285 (20) 185 (13)
707 0.50 Flange Porcelain
Differential 316SS 275 (20) 182 (13)
A105 285 (20) 185 (13)
708 Flange SS
316SS 275 (19) 182 (13)

Displacer units are not available over 450°F (232°C).


*An operating specific gravity is required for models 705 through 708 at time of order.

Step 2: Process Connection Material


702 A -F7A-B-A1-N4-CRTT

Select a process connection material from the chart below. Maximum working pressure in the chart
above is based on the material selected here. Consult the factory for alternative materials.

Designator Material
A A105 Carbon Steel fittings or flanges
C A182-TP316/316L Stainless Steel fittings or flanges

sorinc.com Form 912


913-888-2630 Registered Quality System to ISO 9001:2008 33/60
700 Series Step 3: Process Connection
702 A -F7A-B-A1-N4-CRTT
Select a process connection style, size and rating from the chart below. Consult the factory for
variations. Flanged process connections may reduce the maximum working pressure of the unit.

Model
Size Style
701 702 703 704 705 706 707 708
2-1/2” NPT F7A F7A - - F7A F7A - -
NPT F3A F3A - - F3A F3A - -
3” 150# RF Flange - - F3C F3C - - F3C F3C
300# RF Flange - - F3D F3D - - F3D F3D
150# RF Flange - - F4C F4C - - F4C F4C
4”
300# RF Flange - - F4D F4D - - F4D F4D
150# RF Flange - - F6C F6C - - F6C F6C
6”
300# RF Flange - - F6D F6D - - F6D F6D

Step 4: Trim Material


702 A -F7A-B-A1-N4-CRTT
Select the internal trim material from the chart below.

Displacer Attraction Construction Model


Material Sleeve Material 701 702 703 704 705 706 707 708
316/316L SS 400SS A only - B - B - B - B
316/316L SS 316/316L SS A or C - C - C - C - C
Porcelain 400SS A only P - P - P - P -
Porcelain 316/316L SS A or C R - R - R - R -
Standard displacer spring material is Inconel 600.

Form 912 sorinc.com


34/60 Registered Quality System to ISO 9001:2008 913-888-2630
700 Series Unit Dimensions
Dimensions in this catalog are for reference only. They may be changed without notice. Contact the
factory for certified drawings for a particular model number. Dimensions are expressed as millimeters
over inches. (Linear = mm/in.)
Model 701/703 Model 702/704
2-1/2” NPT/Flanged 2-1/2” NPT/Flanged
MODEL # SALES ORDER # LINE ITEM # PURCHASE ORDER #

MODEL #
Narrow Differential SALES ORDER #
Narrow Differential
LINE ITEM # PURCHASE ORDER #
SALES PAGE 1 * MINIMUM
146.1
5.75
OVERHEAD CLEARANCE REQUIRED
TO REMOVE HOUSING COVER.
NPT A
180.9 180.9
180.9 180.9
7.12 7.12
7.12 7.12 B
FLANGE
101.6
4.00
101.6 101.6
4.00 4.00 Narrow Differential
101.6
DIMENSION
4.00 C
Models 701-704:
SEE CHART

Actuation DIMENSION
differential
D is approximately
SEE CHART

1-7/16’’ @ Specific
ELECTRICAL CONNECTION W Gravity of 1.0 @ 100°F.
*227.0 *227.0
*227.0 8.94 8.94 DIMENSION C
*227.0
8.94 8.94
W FLANGE
W SIZE
Wide Differential Models 705-708:
PROCESS
CONNECTION 150 # 300 # 600 #PROCESS
CONNECTION
W 2-1/2 NPT(M)(STD) 62.7 67.6 70.6 FLANGED
W
Actuation differential is 77.0
adjustable from
3 NPT(M)(OPT) 3"
2.47 2.66 2.78
PROCESS
PROCESS 62.7 70.6
CONNECTION 4"
D
CONNECTION
NPT A 84.9
C FLANGE B approximately
62.7
2.47 6"
64.3 9–1/2”
2.47 2.78
75.4
3.03
86.6
3.34
(minimum @ Specific Gravity of 1.0 @100°F)
2.53 2.97 3.41
MINIMUM MINIMUM
DIMENSION D
3048 229 3048 229

MINIMUM
120.0
316 SST
9.0
MINIMUM
229
to available
120.0
316 SST cable
2-1/2 NPTM length.
9.0 84.9
3.34 ELECTRICAL CONN. "W" : __________
229 CABLE
3048 CABLE 87.9
3048 9.0 3 NPTM
9.0 120.0 3.46
120.0 316 SST
316 SST HIGH 146.1 HIGH 14685 W 105TH ST LENEXA, KS 66215 USA
CABLE
190.5 * MINIMUM OVERHEAD CLEARANCE 913-888-2630
CABLE 190.5 5.75
7.50 SWITCHCOVER SORINC.COM
SWITCH REQUIRED
7.50 TO REMOVE HOUSING ISO-9001

ACTUATION ACTUATION DRAWN BY


14685 W 105TH ST LENEXA, KS 66215 USA
316 SST
LOW
316 SST
DISPLACER ISO-9001
Housing**
913-888-2630
LOW
SORINC.COM
W PRODUCT CERTIFICATION DRAWING
ALL DIMENSIONS ARE ±1/16 IN
JFIXSEN
CHECKED BY

DISPLACER HIGH UNLESS OTHERWISE SPECIFIED


JKENT
HIGH ENGINEER APPROVAL

General Purpose N4
DRAWN BY
MM
K MITCHELL LINEAR = SBOAL
IN
SWITCH 195.6 SWITCH PRODUCT CERTIFICATION DRAWING CHECKED BY DATE
195.6
ACTUATION 7.70 63.5 ACTUATION Explosion
UNLESSProof
ALL 63.5
N7
DIMENSIONS ARE ±1/16 IN
OTHERWISE SPECIFIED
J REHM 2/4/03
7.70
2.50 2.50 MM
ENGINEER APPROVAL
1” NPT THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
LOW
MODEL 702
LOW Explosion ProofLINEAR =
IN
MODEL 704
B1 R SAVERINO
DATE
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
SCALE 0.2 Explosion Proof SCALE 0.2 B2
27 JUL 2011
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
TITLE

NO USE WHATSOEVER OF THE INFORMATION CONTAINED DIM DWG 702, 704

Drawing 0390670 Drawing 0390671 HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
NARROW DIFFERENTIAL
EO NUMBER: 4441 DRAWING NUMBER REV
65.7 PORCELAIN
Pneumatic P1 (3) 1/4” SCALE:
NPT0.20
TITLE
65.7 PORCELAIN DIMENSION DRAWING 701, 703
0390671 1
2.59 DISPLACER 2.59 DISPLACER DWG SIZE
NARROW DIFFERENTIAL SHEET 1 OF 1
DRAWING NUMBER REV
DO NOT SCALE PRINT B
Model Name: 0390671_704.ASSEM/1/4+ MODEL 703 EO NUMBER: 4441
MODEL 701 0390670 1 Reset Form
SCALE 0.25 SCALE 0.25 SCALE: 0.25
ATEX DO NOT SCALE PRINT
T6
SHEET 1 OF 1
B
DWG SIZE

Model Name: 0390670.ASSEM/1/7+


Flame Proof S3 w/CL
Reset Form
M20 x 1.5***
Model 705/707 Model 706/708 SAA S3
2-1/2” NPT/Flanged 2-1/2” NPT/Flanged Flame Proof S8
Wide Differential Wide Differential
* Minimum 5-3/4’’ (146 mm) overhead clearance
required to remove housing cover.
** See Switch Housing section (page 48).
*** M20 adapters are brass. Contact the factory for
alternate materials.

Drawing 0390672 Drawing 0390673

sorinc.com Form 912


913-888-2630 Registered Quality System to ISO 9001:2008 35/60
730 Series Step 1: Model Series
731 A-F7A-B-A2-N4-CRTT

The 730 Series mechanical liquid level switches are dual-stage, displacer-operated switches
suitable for top-insertion tank mounting. Select the sensing unit from the following charts. Then
refer to pages 44 - 50 for switching elements, housings and accessories.
Select a model series from the charts below based on maximum operating pressure and minimum
specific gravity.

Maximum Working Pressure


Minimum Pressure Rating - psig (bar)
Model Connection Displacer Connection
Specific Function
Series Style Material Material 100°F (38°C) 450°F (232°C)
Gravity
730 0.72 Porcelain All 1000 (69) 750 (52)
NPT
731 0.64 SS All 1000 (69) 750 (52)
Narrow A105 285 (20) 185 (13)
732 0.72 Flange Porcelain
Differential 316SS 275 (19) 182 (13)
A105 285 (20) 185 (13)
733 0.64 Flange SS
316SS 275 (19) 182 (13)
734 Porcelain All 1000 (69) 750 (52)
NPT
735 SS All 1000 (69) 750 (52)
Wide A105 285 (20) 185 (13)
736 0.64 Flange Porcelain
Differential 316SS 275 (20) 182 (13)
A105 285 (20) 185 (13)
737 Flange SS
316SS 275 (19) 182 (13)

Displacer units are not available over 450oF (232oC).


*An operating specific gravity is required for all 730 series at time of order.

Step 2: Process Connection Material


731 A -F7A-B-A2-N4-CRTT
Select a process connection material from the chart below. Maximum working pressure in the chart
above is based on the material selected here. Consult the factory for alternative materials.

Designator Material
A A106 Carbon Steel fittings or flanges
C A182-TP316/316L Stainless Steel fittings or flanges

Form 912 sorinc.com


36/60 Registered Quality System to ISO 9001:2008 913-888-2630
730 Series Step 3: Process Connection
731 A -F7A-B-A2-N4-CRTT
Select a process connection style, size and rating from the chart below. Consult the factory for
variations. Flanged process connections may reduce the maximum working pressure of the unit.

Model
Size Style
730 731 732 733 734 735 736 737
2-1/2” NPT F7A F7A - - F7A F7A - -
NPT F3A F3A - - F3A F3A - -
3” 150# RF Flange - - F3C F3C - - F3C F3C
300# RF Flange - - F3D F3D - - F3D F3D
150# RF Flange - - F4C F4C - - F4C F4C
4”
300# RF Flange - - F4D F4D - - F4D F4D
150# RF Flange - - F6C F6C - - F6C F6C
6”
300# RF Flange - - F6D F6D - - F6D F6D

Step 4: Trim Material


731 A -F7A-B-A2-N4-CRTT
Select the internal trim material from the chart below.

Displacer Attraction Construction Model


Material Sleeve Material 730 731 732 733 734 735 736 737
316/316L SS 400SS A only - B - B - B - B
316/316L SS 316/316L SS A or C - C - C - C - C
Porcelain 400SS A only P - P - P - P -
Porcelain 316/316L SS A or C R - R - R - R -

Standard displacer spring material is Inconel 600.

sorinc.com Form 912


913-888-2630 Registered Quality System to ISO 9001:2008 37/60
730 Series Unit Dimensions
Dimensions in this catalog are for reference only. They may be changed without notice. Contact the
factory for certified drawings for a particular model number. Dimensions are expressed as millimeters
over inches. (Linear = mm/in.)

Model 730/732 Model 731/733


2-1/2” NPT/Flanged 2-1/2” NPT/Flanged
Narrow Differential Narrow Differential SALES PAGE 1
MODEL # SALES ORDER # LINE ITEM # PURCHASE ORDER #
MODEL # SALES ORDER # LINE ITEM # PURCHASE ORDER #

180.9 180.9 NPT A


180.9 180.9 146.1
7.12 7.12 * MINIMUM OVERHEAD CLEARANCE REQUIRED
7.12 7.12 5.75
101.6 101.6 FLANGE B TO REMOVE HOUSING COVER.
4.00 101.6
4.00 101.6
4.00 4.00
DIMENSION C SEE CHART

DIMENSION D SEE CHART

*227.0 *227.0 ELECTRICAL CONNECTION W


*227.0 *227.0
8.94 8.94 8.94
8.94
DIMENSION C
W W
W W FLANGE
SIZE PROCESS
PROCESS 150 # 300 # CONNECTION
600 #
C
CONNECTION
D FLANGED
2-1/2 NPT(M) 62.7 67.6 70.6
PROCESS 3"
2.47 2.66 2.78
PROCESS CONNECTION
62.7 70.6 77.0
CONNECTION FLANGE B 4"
2.47 2.78 3.03
NPT A 62.7
84.9 2.47 64.3 75.4 86.6
3.34 6"
MINIMUM MINIMUM 2.53 2.97
MINIMUM 3.41
229 MINIMUM
229 229 DIMENSION D229
3048 9.0 3048 9.0 3048 9.0
120.0 3048
120.0 9.0 84.9
120.0 2-1/2 NPTM
316 SST 120.0
316 SST 3.34
316 SST
CABLE 316 SST
CABLE
CABLE CABLE 3 NPTM Housing**
87.9
3.46
W
HIGH 146.1
HIGH * MINIMUM OVERHEAD CLEARANCE
HIGH
HIGH 316 SST
5.75 General Purpose
316 SSTCOVER
REQUIRED TO REMOVE HOUSING
N4 ELECTRICAL CONN. "W" : __________
DISPLACER DISPLACER
PORCELAIN PORCELAIN HIGH
Explosion Proof
14685 W 105TH ST LENEXA, KS 66215 USA N7
DISPLACER DISPLACER
LOW
913-888-2630
1”
14685 W 105TH ST NPT
LENEXA, KS 66215 USA

HIGH
LOW LOWHIGH LOW HIGH
ISO-9001
Explosion Proof
SORINC.COM
DRAWN BY
B1 913-888-2630
SORINC.COM
ISO-9001
SWITCH HIGH SWITCH SWITCH
ACTUATION SWITCH ACTUATION
ACTUATION
ACTUATION
PRODUCT Explosion Proof
CERTIFICATION DRAWING
LOW
LOWALL DIMENSIONS ARE ±1/16 IN
K MITCHELL
CHECKED BY

M SMITH
B2 PRODUCT CERTIFICATION DRAWING JFIXSEN DRAWN BY

CHECKED BY
HIGH HIGH SWITCH UNLESS OTHERWISE SPECIFIED ENGINEER APPROVAL ALL DIMENSIONS ARE ±1/16 IN
JKENT
HIGH MM UNLESS OTHERWISE SPECIFIED
ACTUATION LINEAR =
IN J FIFE ENGINEER APPROVAL
195.6 DATE LINEAR =
MM
SBOAL
195.6
Pneumatic P1 (3) 1/4” NPT
7.70 IN
21 JUN 2011 DATE
7.70 THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR. 2/4/03
LOW LOW NO USE WHATSOEVER OF THE INFORMATION CONTAINED
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
LOW LOW LOW HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
SWITCH SWITCH LOW MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
ACTUATION ACTUATION SWITCH TITLE

65.7
ACTUATION
63.5 NARROW DIFFERENTIAL ATEX
DIMENSION DRAWING 730, 732
T6 DIM DWG 731, 733
TITLE

2.50 65.7 DRAWING NUMBER REV NARROW DIFFERENTIAL


Flame Proof S3 w/CL
EO NUMBER: 5090
2.59 2.59 63.5
MODEL 730 MODEL 731 0390677 3 EO NUMBER: 4441 DRAWING NUMBER REV
MODEL 732 2.50
SCALE: 0.20
SCALE 0.2 SCALE 0.2
M20SHEET
x0390678
1.5*** 1
DWG SIZE
SCALE 0.2 DO NOT SCALEMODEL 733SHEET 1 OF 1 SCALE: 0.20
Drawing 0390677 Drawing 0390678
PRINT B DWG SIZE

SCALE 0.2 1 OF 1
SAA S3
Model Name: 0390672.ASSEM/1/6+ DO NOT SCALE PRINT B
Model Name: 0390673.ASSEM/1/7+
Reset Form
Reset Form
Flame Proof S8

* Minimum 5-3/4’’ (146 mm) overhead clearance


Model 734/736 Model 735/737 required to remove housing cover.
2-1/2” NPT/Flanged 2-1/2” NPT/Flanged ** See Switch Housing section (page 48).
Wide Differential Wide Differential *** M20 adapters are brass. Contact the factory for
alternate materials.

Drawing 0390679 Drawing 0390680

Form 912 sorinc.com


38/60 Registered Quality System to ISO 9001:2008 913-888-2630
730 Series Specific Gravity Ranges

Optional Switching Arrangements


Dual-stage, wide differential switches may be ordered with switching arrangements different from
those shown on page 38. To order, select the desired arrangement below and add SC to the
accessory section of the model number. At the time of order, specify the required arrangement
number. Porcelain displacers are shown for pictorial purposes only.

Arrangement 1 Arrangement 2 Arrangement 4 Arrangement 5 Arrangement 6

Switch Position

sorinc.com Form 912


913-888-2630 Registered Quality System to ISO 9001:2008 39/60
750 Series Step 1: Model Series
751 A-F7A-B-A3-N1-CRTT

The 750 Series mechanical level switches are three-stage, displacer-operated switches suitable for
top-insertion tank mounting. Select the sensing unit from the following charts. Then refer to pages
44 - 50 for switching elements, housings and accessories.

Maximum Working Pressure


Minimum Pressure Rating - psig (bar)
Model Connection Displacer Connection
Specific Function
Series Style Material Material 100°F (38°C) 450°F (232°C)
Gravity
750 0.96 Porcelain All 1000 (69) 750 (52)
NPT
751 0.85 SS All 1000 (69) 750 (52)
Narrow A105 285 (20) 185 (13)
752 0.96 Flange Porcelain
Differential 316SS 275 (19) 182 (13)
A105 285 (20) 185 (13)
753 0.85 Flange SS
316SS 275 (19) 182 (13)
754 0.96 Porcelain All 1000 (69) 750 (52)
NPT
755 0.95 SS All 1000 (69) 750 (52)
Wide A105 285 (20) 185 (13)
756 0.96 Flange Porcelain
Differential 316SS 275 (20) 182 (13)
A105 285 (20) 185 (13)
757 0.95 Flange SS
316SS 275 (19) 182 (13)

Displacer units are not available over 450oF (232oC).


*An operating specific gravity is required for all 750 series at time of order.

Step 2: Process Connection Material


751 A -F7A-B-A3-N1-CRTT
Select a process connection material from the chart below. Maximum working pressure in the chart
above is based on the material selected here. Consult the factory for alternative materials.

Designator Material
A A105 Carbon Steel fittings or flanges
C A182-TP316/316L Stainless Steel fittings or flanges

Form 912 sorinc.com


40/60 Registered Quality System to ISO 9001:2008 913-888-2630
750 Series Step 3: Process Connection
751A -F7A-B-A3-N1-CRTT

Select a process connection style, size and rating from the chart below. Consult the factory for
variations. Flanged process connections may reduce the maximum working pressure of the unit.

Model
Size Style
750 751 752 753 754 755 756 757
2-1/2” NPT F7A F7A - - F7A F7A - -
NPT F3A F3A - - F3A F3A - -
3” 150# RF Flange - - F3C F3C - - F3C F3C
300# RF Flange - - F3D F3D - - F3D F3D
150# RF Flange - - F4C F4C - - F4C F4C
4”
300# RF Flange - - F4D F4D - - F4D F4D
150# RF Flange - - F6C F6C - - F6C F6C
6”
300# RF Flange - - F6D F6D - - F6D F6D

Step 4: Trim Material


751 A -F7A-B-A3-N1-CRTT
Select the internal trim material from the chart below.

Displacer Attraction Construction Model


Material Sleeve Material 750 751 752 753 754 755 756 757
316/316L SS 400SS A only - B - B - B - B
316/316L SS 316/316L SS A or C - C - C - C - C
Porcelain 400SS A only P - P - P - P -
Porcelain 316/316L SS A or C R - R - R - R -

Standard displacer spring material is Inconel 600.

sorinc.com Form 912


913-888-2630 Registered Quality System to ISO 9001:2008 41/60
750 Series Dimensions

Dimensions in this catalog are for reference only. They may be changed without notice. Contact the
factory for certified drawings for a particular model number. Dimensions are expressed as millimeters
over inches. (Linear = mm/in.)

Model 750/752 Model 751/753 Model 754/756 Model 755/757


2-1/2” NPT/Flanged 2-1/2” NPT/Flanged 2-1/2” NPT/Flanged 2-1/2” NPT/Flanged
SALES PAGE 1
MODEL # SALES ORDER # LINE ITEM # PURCHASE ORDER #

NPT A
180.9 180.9
7.12 7.12 FLANGE B
101.6 101.6
4.00 4.00 DIMENSION C SEE CHART

DIMENSION D SEE CHART

ELECTRICAL CONNECTION W
*306.4
*306.4 12.06
12.06
DIMENSION C
W
W PROCESS
FLANGE
PROCESS CONNECTION SIZE
CONNECTION FLANGE B 150 # 300 # 600 #
NPT A C
D 62.7 67.6 70.6
3"
2.47 2.66 2.78
62.7 70.6 77.0
4"
3048 MINIMUM 3048 MINIMUM 2.47 2.78 3.03
120.0 229 120.0 229 64.3 75.4 86.6
316 SST 316 SST 9.0 6"
9.0 2.53 2.97 3.41
CABLE CABLE
DIMENSION D

HIGH HIGH 84.9


2-1/2 NPTM
3.34
87.9
3 NPTM
3.46
TOP LOW LOW 222.3
TOP * MINIMUM OVERHEAD CLEARANCE
SWITCH SWITCH 8.75
ACTUATION ACTUATION REQUIRED TO REMOVE HOUSING COVER
HIGH HIGH 316 SST
316 SST DISPLACER 14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
DISPLACER SORINC.COM
ISO-9001

MIDDLE LOW LOW DRAWN BY


MIDDLE K MITCHELL
SWITCH SWITCH PRODUCT CERTIFICATION DRAWING CHECKED BY

ACTUATION ALL DIMENSIONS ARE ±1/16 IN


ACTUATION J REHM
HIGH HIGH UNLESS OTHERWISE SPECIFIED ENGINEER APPROVAL
MM
190.5 LINEAR = R SAVERINO
190.5 IN
DATE
7.50 7.50 27 JUL 2011
LOW LOW THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
BOTTOM BOTTOM NO USE WHATSOEVER OF THE INFORMATION CONTAINED
SWITCH SWITCH HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
ACTUATION ACTUATION TITLE
63.5 63.5 DIMENSION DRAWING 751, 753
2.50 2.50 NARROW DIFFERENTIAL
MODEL 751 MODEL 753 DRAWING NUMBER REV

Drawing 0390681 Drawing 0390682 Drawing 0390683 Drawing 0390684


EO NUMBER: 5123
SCALE 0.15 SCALE 0.15 0390682 3
SCALE: 0.15 DWG SIZE
SHEET 1 OF 1
DO NOT SCALE PRINT B
Model Name: 0390682.ASSEM/2/0
Reset Form

* Minimum 8-3/4’’ (222 mm) overhead clearance required to remove housing cover.

Housing** W
Explosion Proof B5
General Purpose N1 1” NPT
Explosion Proof N8
** See Switch Housing
section (Page 48).

Form 912 sorinc.com


42/60 Registered Quality System to ISO 9001:2008 913-888-2630
750 Series Specific Gravity Ranges

Optional Switching Arrangements


Three-stage, wide differential switches may be ordered with switching arrangements different
from those shown on page 39. To order, select the desired arrangement below and add SC to
the accessory section of the model number. At the time of order, specify the required arrangement
number. Porcelain displacers are shown for pictorial purposes only.
Arrangement B Arrangement C Arrangement D Arrangement E Arrangement F

Arrangement G Arrangement H Switch Position

sorinc.com Form 912


913-888-2630 Registered Quality System to ISO 9001:2008 43/60
Mechanical
Level Switches Switching Mechanisms

SOR switching mechanisms are designed for use in harsh industrial atmospheres. SOR offers a
variety of electrical and pneumatic switching mechanism types to fit a wide range of applications.
The basic types of switch mechanisms available are listed below. See page 47 for specifications.

All SOR switching mechanisms are constructed from stainless steel and other durable
manufactured materials. Each mechanism is individually calibrated and inspected to insure
accuracy and repeatability. See below for the benefits and application of each switch type.
All mechanisms are interchangeable with most competitor units.

Standard Dry-Contact Switches


Types A, B, C, E
Standard dry-contact switches have open mechanisms and
exposed switching elements. These switching mechanisms are
easy to maintain. Visual confirmation of operation is obvious.
Dry-contact switch mechanisms are recommended for most level
switch applications and are available in SPDT and DPDT switch
arrangements.

Dry-Contact Switch Mechanisms feature:


 High-load carrying capacity
 High-quality phenolic insulator
 Vibration resistance

 Versatility of application

Mini-Hermetically Sealed Switches


Types L, S, T, V
Mini-hermetically sealed switches have a hermetically sealed
switch element on an exposed mechanism. Good for high-
temperature service and normal applications that require
hermetically sealed contacts.

Mini-Hermetically Sealed Switch Mechanisms feature:


 Rugged stainless steel construction

 Class I Group A rating for use in hazardous areas

 Vibration resistance

 High operating temperature limits

Anti-Vibration Switches
Types D and R
Anti-Vibration Switches employ two magnets to provide
vibration protection. Dual magnets prevent false trips by
providing a positive mechanical lock to the enclosing tube
when the switch is in any position.
(Type T switches are mini-hermetically sealed units with
dual magnets.)

Form 912 sorinc.com


44/60 Registered Quality System to ISO 9001:2008 913-888-2630
Mechanical
Level Switches Switching Mechanisms

Pneumatic Switch
Type J
Pneumatic switches are available for applications that prohibit
electrical switching or where electricity is not available.

Pneumatic switches feature:


 Three-way aluminum valve

 Anti-vibration design

 1/4" NPT ports in 316SS for additional

corrosion resistance

Extra-High Temperature Switch


Type Y
The Y Series level switch mechanism is designed to
operate normally under extremely high-temperature
conditions. Constructed of stainless steel, ceramic, and
oxidation-resistant alloys, the Y Series is designed to
counteract the warping and seizure normally associated with
this type of mechanism in high temperatures. The Y Series
switch is especially well suited for power plant conditions.
Y Series Switch Mechanisms feature:
 Mica/glass insulation on wires and switches

 Stainless steel and ceramic switch element

and terminal block


 Switch mechanism rated at 800°F (427°C)

continuous process temperature


• Can be combined with external temperature
protection to function in temperatures up to
1200°F (649°C)
• Dual magnets for vibration protection

sorinc.com Form 912


913-888-2630 Registered Quality System to ISO 9001:2008 45/60
Mechanical
Level Switches Switching Mechanisms
741A -A1C-B-A1-N4-CRTT
Select the switch mechanism from the chart below.

SPDT DPDT Available


3-Way
Switch Type Single Pole Double Pole Agency
Valve
Double Throw Double Throw Listings
Switching Stages Single Dual Triple Single Dual Triple Single

ATEX
CSA

SAA
UL
Switching Description Switch Designator
Standard Dry Contact A1 A2 A3 A4 A5 A8 - l l l l
High-Temperature Dry Contact B1 B2 B3 B4 B5 B8 - l l l l
Gold Contact C1 C2 C3 C4 C5 C8 - l l l l

Anti-Vibration Dry Contact1 D11 - - D41 - - - l l l l


High-Amperage DC Service E1 E2 E3 E4 E5 E8 - l l l l

Standard Mini-Hermetically Sealed L1 L2 L3 L4 L5 L8 - l l l l

1 1 1
Anti-Vibration Gold Contact R1 - - R4 - - - l l l l

Gold Contact Mini-Hermet S1 S2 S3 S4 S5 S8 - l l l l


Anti-Vibration Mini-Hermet1 T11 - - T41 - - - l l l l
High-Temperature Mini-Hermet V1 V2 V3 V4 V5 V8 - l l l

Extra-High Temperature (Ceramic) Y11 - - Y41 - - - l l l l


Pneumatic Non-Bleed with 316SS - - - - - - J01,2
Fittings
Available with models:
Series 100-200-300-740-800 l l l l l l l l l
Series 108/208-400 l l l l l l l
Series 700 l l l l l l l

Series 730 l l l l l l
Series 750 l l l
(enclosures N1, N8 or B5 only)

Notes
1. These switches use two magnets and must be considered dual mechanisms when figuring minimum
specific gravity.
2. Pneumatic switching mechanisms must be specified with P1 housing.

Form 912 sorinc.com


46/60 Registered Quality System to ISO 9001:2008 913-888-2630
Mechanical
Level Switches Switch Ratings

Resistive Amperage Inductive Amperage

110-130VDC

210-250VDC

110-130VDC

210-250VDC
110-130VAC

210-250VAC

110-130VAC

210-250VAC
Minimum Maximum

20-30VDC

20-30VDC
Switch Designator
Temperature1 Temperature2

A Standard Dry Contact 15 15 5 .5 .25 15 15 5 .4 .13 -15°F (-26°C) 250°F (121°C)


Hi-Temperature Dry
B 5 5 1.5 .5 - 5 5 1 .25 - -15°F (-26°C) 400°F (204°C)
Contact
C Gold Contact 1 - 1 - - 1 - .5 - - -15°F (-26°C) 250°F (121°C)
D Anti-Vibration 15 15 5 .5 .25 15 15 5 .4 .13 -15°F (-26°C) 250°F (121°C)
E High-Amp DC - - 10 10 3 - - 10 10 3 -15°F (-26°C) 250°F (121°C)
Mini- DPDT 5 5 5 .5 - 5 5 2.5 .25 -
L5 Hermetically -15°F (-26°C) 250°F (121°C)
Sealed SPDT 11 11 5 .5 .25 11 11 2.5 .25 .13
Anti-Vibration Gold
R 1 - 1 - - 1 - .5 - - -15°F (-26°C) 250°F (121°C)
Contact
Gold Contact Mini-
S 1 - 1 - - 1 - .5 - - -15°F (-26°C) 250°F (121°C)
Hermet

Anti-Vibration DPDT 5 5 5 .5 - 5 5 2.5 .25 - -15°F (-26°C) 250°F (121°C)


T5
Mini-Hermet SPDT 11 11 5 .25 .25 11 11 2.5 .5 .13 -15°F (-26°C) 250°F (121°C)
High-Temperature
V 5 5 1.5 .5 - 5 5 1 .25 - -15°F (-26°C) 400°F (204°C)
Mini-Hermet
Extra-High Temperature
Y 1 1 1 .4 - 1 1 .4 - - -40°F (-40°C) 800°F (427°C)
(Ceramic) Note 3

Non-bleed 3-way aluminum valve body.


J4 Pneumatic 316SS
Buna-N O-Rings 5F (-15°C) 200°F (93°C)
Fittings
150 psig maximum supply, 24CFM @ 100 psig

Notes
1. Minimum ambient temperature at which the switch mechanism will operate normally. This may vary
according to actual climatic conditions. Actual minimum process temperature may be much lower.
Consult the factory for details.
2. Maximum process temperature at which the switch mechanism will operate normally. This can be increased
according to the type of process. Refer to pages 51 - 52 for more details.
3. -40°F Temperature rating with no icing.
4. Pneumatic switches must be used with clean, dry air or gas.
5. These switch designators have higher current rating for SPDT than DPDT.

sorinc.com Form 912


913-888-2630 Registered Quality System to ISO 9001:2008 47/60
Mechanical
Level Switches Housings
741A -A1C-B-A1-N4-CRTT
SOR housings are designed to protect the switching mechanisms from harsh environmental
conditions, as well as protecting the surrounding atmosphere from potential ignition sources. The
basic types of housings are listed below.
General Purpose, NEMA 4 Housings
are heavy duty cast aluminum. All housings are
rated NEMA 4 (IP65) as a minimum.

Explosion-Proof Housings
are available in aluminum or cast iron. Explosion-Proof ratings include
Class I, Group B, C, D; Division 1 & 2, and EEx d IIC T6 (ATEX) and
Ex d IIC T6 (SAA).

Pneumatic Switch Housings


are required for use with a pneumatic switching mechanism. These
enclosures are General Purpose, NEMA 4 (IP65) only.
NEMA 4X Housings
are standard in aluminum. Cast iron enclosures can be rated NEMA 4X by adding epoxy
coating.

Switch Housings
Select the housings from the chart below.

Agencies Available with Models

100, 200, 300

108, 208, 400


Designator Description Enclosure Rating2

740, 800

750’s
730’s
700’s
ATEX
CSA

SAA
UL

B1 Aluminum Groups B, C, & D £ £ £ £ £ £ £

B22 Cast Iron Groups B, C, & D £ £ £ £ £ £ £

B5 Aluminum Extended Groups B, C, & D £ £

N1 Aluminum Extended NEMA 4, 4X £ £

N4 Aluminum NEMA 4, 4X £ £ £ £ £ £ £
2
N6 Cast Iron Double Hub Groups C & D £ £ £ £ £ £

N7 Aluminum Groups C & D £ £ £ £ £ £ £

N8 Aluminum Extended Groups C & D £ £


1
P1 Aluminum Pneumatic NEMA 4, 4X £ £ £ £

Ex d IIC T6 (SAA)
S3 Aluminum £ n £ £ £ £ £
EEx d IIC T6 (ATEX)
S82 Cast Iron Ex d IIC T6 (SAA) n £ £ £ £ £
2
T6 Cast Iron EEx d IIC T6 (ATEX) n £ £ £ £ £

— Available
 — Standard (Agency listing accessory designator is not needed.)
1. P1 housing must be used with pneumatic switch mechanisms.
2. All cast iron housings can be rated NEMA 4X by adding PY to the accessory section of the model number.

Form 912 sorinc.com


48/60 Registered Quality System to ISO 9001:2008 913-888-2630
Mechanical
Level Switches Accessories
SOR accessories are provided for customizing the level switches in this 741A -A1C-B-A1-N4-CRTT
catalog according to the requirements of the application. Place accessory designator(s) from the table below at the
end of the model number. Check the compatibility chart below for correct use of each accessory.
Accessory Compatibility Chart
Model Series

Description 741-743 740


108/
100 200 300 400 801 803 700 730 750
208
802 804
AF1 Air Filter & Gauge l l l l l l l l
FE Finned Extention l l l l
CL ATEX Approved for S3 Hsg l l l l l l l l l
CN7 Conduit Reducer M20 x 1.5 l l l l l l l l l l
CP7 Conduit Reducer 1/2” NPT l l l l l l l l l l
CR7 Conduit Reducer 3/4” NPT l l l l l l l l l l
CS2 CSA Certification l l l l l l l l l l
CV Canadian Registration Number (CRN) l l l l l l l l l l
CY Certificate of Conformance l l l l l l
(power plant piping, ANSI 31.1)
CZ3 Certificate of Conformance l l l l l l
(petrochemical piping, ANSI 31.3)
DN Special Drain Connection l l l l
EC8 Extra Chamber Connection C/F C/F C/F C/F C/F
ET5 Temperature Extension l l l l l l l l l l
FE Finned Extention l l l l
GG Sealed Conduit l l l l l l l l l
ID9 Interface Detection l l l l l
KK Housing Breather Drain l l l l l l l l l l
MC4 Manual Check l l
MR Mill Test Report l l l l l l l l l l
MT Mag Particle Examination l l l l l l
NC NACE Construction l l l l l l l l l l
PP Fiber Tag l l l l l l l l l l
PT Dye Penetration Examination l l l l l l
PY Powder coat epoxy coating. No coating on
stainless steel parts or plated screws. l l l l l l l l l l
(500 hrs. salt spray)
RR SS Tag wired to housing l l l l l l l l l l
RT Radiograph Examination l l l l l l
SC10 Special Calibration C/F C/F C/F C/F C/F C/F C/F C/F C/F C/F
SD11 Special Dimensions C/F C/F C/F C/F C/F
SL12 Special Cable Length l l l
TC4 Tru-Check l l
TF Tandem Floats C/F C/F l
TT Oversized Nameplate for customer tagging l l l l l l l l l l
UT Ultrasonic Examination l l l l l l
VV Fungicidal Varnish l l l l l l l l l l
WC Water Column Unit C/F
WV2 UL Listed l l l l l l l l l
YY Epoxy Coating (enclosure only) l l l l l l l l l l
Notes C/F = Consult the Factory
1. Pneumatic switching mechanisms only (P1) 6. Not available with agency-listed housings.
2. Consult switch and housing sections for agency availability. 7. Not available with T6 and S3 (ATEX) housings.
3. Process media must be known prior to manufacture. Different 8. Need connection size, type, and location on chamber.
processes (service categories) require different quality 9. The upper and lower specific gravity required to determine functionality.
inspection procedures. Consult the factory for details. 10. Operating specific gravity, Set Point (referenced from upper
4. Appropriate for Model Series 701 through 704 and 730 process connection) and if Set Point is rising or falling are required.
through 733. See page 55 for details. Not available with NACE. 11. Specific details of chamber dimensional changes.
5. See high-temperature selection for application. 12. Length of cable required (10 ft. is standard).
sorinc.com Form 912
913-888-2630 Registered Quality System to ISO 9001:2008 49/60
Mechanical
Level Switches Test Certificates

Float Operated Switches


Certificates C1 C2 C3 C4 C5 C6 C7 B2 B3 B5 B6 B7 A2 A3 A4 A7 A8 A9
Series 100 Calibration ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿
Hydrostatic
Series 200 Pressure Test
¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿

Series 220 Inspection


Report
¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿ ¿
Series 300 Compliance /
Conformance
¿ ¿ ¿ ¿ ¿ ¿ ¿
Series 400
Dielectric Test ¿ ¿ ¿
Series Insulation
108/208 Resistance
¿ ¿ ¿ ¿ ¿ ¿

QA Test Report ¿ ¿ ¿ ¿

Displacer Operated Switches


Certificates C1 C3 C4 C5 C6 C7 B5 B6 B7
Calibration ¿ ¿ ¿ ¿
Inspection Report ¿ ¿ ¿ ¿
Series 700, 730, 750
Compliance / Conformance ¿ ¿
*Series 740
Dielectric Test ¿ ¿
*Series 800
Insulation Resistance ¿ ¿ ¿

QA Test Report ¿
*These products also have Certificate C2 - Hydrostatic Pressure Test.

Form 912 sorinc.com


50/60 Registered Quality System to ISO 9001:2008 913-888-2630
Mechanical
Level Switches High Temperature Selection
SOR level switches can accommodate high-temperature applications up to 1200oF (649oC).
These temperatures may be safely reached by a proper combination of chamber material, switch
mechanism and temperature extension. Refer to page 52 to select the proper components for your
process temperature. DRAWING NUMBER

ET Accessory MODEL #
PURCHASE ORDER #
SALES ORDER #

The straight temperature extension provides physical distance 201 A -A1C-B-A1-N4-ET TT


between the process and the switching mechanism. It is 180.9 * MINIMUM
146.1
5.75
constructed of a straight piece of pipe welded between the 7.12 REQUIRED TO REM
101.6
chamber and enclosing tube connection. 4.00

How It Works
The straight temperature extension is designed to remove the
SWITCH
switch from direct radiant heat in dry heat processes. Consult ENCLOSURE
*228.6
the chart on page 52 for application. 9.00

To Specify 14685 W

ISO-9001

Add Accessory Designator ET to the end of the SOR level W


switch model number per the selection chart on the next page. PRODUCT CERTIFICA
ALL DIMENSIONS
TEMPERATURE UNLESS OTHERW
EXTENSION
The ET accessory automatically matches the material and LINEAR =

rating of the specified level switch chamber. This option can THIS DRAWING IS

be supplied on SOR level switches Series 100, 200, 300 NO USE WHATSOEVE
HEREON, NOR REPRO
MADE WITHOUT THE E
and 400. CHAMBER/PROCESS
TITLE

CONNECTION DIM DWG STRAIGHT T


EO NUMBER: 5090
Drawing 0390676 SCALE: DRAWING SCA
FE Accessories DO NOT SCALE PRINT

201 A -A1C-B-A1-N4-FE TT
Model Name: MODEL NAME.DRAFT/2/0+

The finned temperature extension is designed to protect the electrical portion of a level switch
from heat damage due to condensing processes. When used in combination with high-temperature switch
mechanisms, this option allows operation in process temperatures up to 1200oF (649oC).
How It Works
The finned temperature extension condenses process steam and
reduces its heat before it can reach the switching mechanism.
The design reduces steam to its saturation temperature in the
enclosing tube, protecting the switching mechanism from
deterioration due to high temperatures. The process
pressure dictates the saturation temperature, see page 58.
To Specify
Add Accessory Designator FE to the end of the SOR
level switch model number per the selection chart on the
next page.
The finned temp. extension automatically matches the material
and rating of the specified level switch chamber. These options
can be supplied on SOR level switches series 100, 200,108/208,
300 and 400.

Note: For proper cooling, temp. extensions must not be insulated


or placed inside an enclosed structure. High ambient temperatures
(over 100oF/38oC), intense direct sunlight, or heat loading from
adjacent piping or vessels will affect cooling performance.
Consult the factory if any of these conditions exist.

sorinc.com Form 912


913-888-2630 Registered Quality System to ISO 9001:2008 51/60
Mechanical
Level Switches High Temperature Selection
There are two sections to the chart, Steam Heat and Dry Heat. Fundamental differences in condensing
(steam) and non-condensing (dry) heat require different methods of protection.
Steam Heat processes carry it’s heat with the vapor. These processes effectively heat every portion of their
enclosure. To reduce the heat effects of condensing processes, we must either condense or physically block
the vapor. SOR uses a condensing system to avoid the sealing problems associated with blocking the steam.
Dry Heat processes transfer heat through direct conduction. Heat is only passed to the areas where they
touch the enclosure. Therefore, radiant heat is the only concern with these processes. This may be resolved by
adding distance between the process and the protected portion of the control.
To use the selection chart, first select the column that represents the desired maximum temperature. Select
a chamber material that is allowable in the chosen column. Move down to the proper process type section,
Steam Heat or Dry Heat. Within that section, select a switch mechanism from those listed in the chosen
column. The symbol will indicate if a temperature reduction device is required.

High Temperature Selection Chart

≤ 1200oF (649 oC)


≤ 1050oF (566oC)
≤ 1000oF (538oC)

≤ 1100oF (593oC)

≤ 1150oF (621oC)
≤ 750oF (399oC)
≤ 650oF (343oC)
≤ 500oF (260oC)

≤ 900oF (482oC)
≤ 550oF (288oC)

≤ 850oF (454oC)
≤ 450oF (232oC)

≤ 950oF (510oC)
≤ 800oF (427oC)
≤ 700oF (371oC)
≤ 600oF(316oC)
0-400oF (204oC)
Designator

Features

Chamber Material (Select one)


A106B Carbon Steel A
304/304LSS
316/316LSS C

A333 GR.6
­ ­ ­ ­ ­ ­ ­
A335-P11 Chrome Moly ­­­­­­­­­­­ ­­­­­­­­­­­ ­­­­­­­­­­­ ­­­­­­­­­­­ ­­­­­­­­­­­ ­­­­­­­­­­­ ­­­­­­­­­­­ ­­­­­­­­­­­­
A335-P91 ­­­­­­­­­­­

Hastelloy C ­ ­
­ ­
­ ­ ­ ­ ­ ­­­­­­­­­­­ ­­­­­­­­­­­
Alloy-20 ­­­­­­­­­­ ­­­­­­­­­­ ­­­­­­­­­­ ­­­­­­­­­­­ ­ ­
­­­­­­­­­­­ ­ ­­­­­­­­­­­ ­
­­­­­­­­­­­ ­­­­­­­­­­­
Monel-400 ­­­­­­­­­­­ ­­­­­­­­­­

Steam Heat Applications

Switch Mechanism (Select one)


Hi-Temp Dry Contact
B/V n l l v v
or Mini-Hermet

Hi-Temperature Ceramic/SS Y n n n n n n n n n v v v v v v v v

Dry Heat Applications

Switch Mechanism (Select one)


Hi-Temp Mini-Hermet
B/V n l l l l
or Dry Contact
Hi-Temperature Ceramic/SS Y n n n n n n n n n l l l l
For proper cooling, temperature extensions and finned extensions must not be insulated or placed inside an enclosed structure. High ambi-
ent temperatures (over 100ºF/38ºC), intense direct sunlight or heat loading from adjacent piping or vessels will affect cooling
performance. Consult the factory if any of these conditions exist.
n = Switch Only v = Finned Extension l = Temperature Extension

Form 912 sorinc.com


52/60 Registered Quality System to ISO 9001:2008 913-888-2630
Mechanical
Level Switches High Temperature Selection

Float Switch Pressure Ratings (in psi) above 450°F (232°C)

Higher temperatures available with other materials.


Consult with the factory.
500°F 550°F 600°F 650°F 700°F 750°F
Model Material
(260°C) (288°C) (316°C) (343°C) (371°C) (399°C)
101 CS & SS 170 155 140 125 110 95
102 CS & SS 447 435 423 411 400 389
CS 600 575 550 535 535 505
103
SS 480 465 450 445 430 425
104 CS & SS 894 870 846 823 800 778
CS 600 575 550 535 535 505
108
SS 480 465 450 445 430 425
109 CS & SS 170 155 140 125 110 95
121 CS & SS 170 155 140 125 110 95
122 CS & SS 313 304 296 288 280 272
201 CS & SS 201 196 190 185 180 175
202 CS & SS 268 261 254 247 240 233
203 CS & SS 447 435 423 411 400 389
204 CS & SS 1118 1087 1057 1029 1000 972
205 CS & SS 671 652 634 617 600 584
206 CS & SS 894 870 846 823 800 778
207 CS & SS 894 870 846 823 800 778
CS 1857 1857 1857 1857 1783 1610
208
SS 1495 1453 1411 1387 1351 1339
209 CS & SS 403 391 381 370 360 350
221 CS & SS 313 304 296 288 280 272

sorinc.com Form 912


913-888-2630 Registered Quality System to ISO 9001:2008 53/60
Mechanical Examination and Testing
Level Switches Requirements
741A -A1C-B-A1-CYCRTT
Certificate of Conformance
Specify either a CY or CZ option in the accessory section of the model number for a certificate of conformance.
Designator Certificate of Conformance to
CY ASME/ANSI B31.1 Power Piping
CZ ASME/ANSI B31.3 Petrochemical Piping
If certification to B31.3 is required, SOR must know the fluid category per the chart below. Refer to the
ASME/ANSI B31.3 Fluid Category Section to determine the applicable category.

ANSI/ASME B31.3 Fluid Category


Normal A fluid service not subject to the following four categories.
Category D A fluid service in which all of the following apply:
1. The fluid handled is non-flammable, non-toxic, and not damaging to human skin.
2. The design gage pressure does not exceed 150 psi.
3. The design temperature is between -20°F and 366°F.
Category M A fluid service in which the potential for personnel exposure is judged to be
significant and in which a single exposure to a very small quantity of a toxic fluid,
caused by leakage, can produce serious irreversible harm to persons on breathing
or bodily contact, even when prompt restorative measures are taken.
Severe Cyclic A fluid service with high-cycle rates that cause extreme stress on components.
High Pressure Pressure in excess of that allowed by the ASME B16.5 Class 2500 rating for the
specified temperature and material group or any piping so designated by the customer.

Weld Examination
When CY or CZ is specified, SOR performs examination to meet these codes. This includes visual
inspection and ultrasonic, X-ray, magnetic particle or dye penetrant testing as required by ASME
B31.1 or B31.3. If CY or CZ is not selected but examination is required, accessories UT (ultrasonic),
RT (X-ray), MT (magnetic particle) or PT (dye penetrant) can be added to the model number to
include this testing.

Hydrostatic Testing
SOR performs a hydrostatic pressure test on all welded chambers at 1.5 times the design pressure
for three minutes. CY and CZ options and Hydrotest Certificates include a hydrostatic pressure test
at 1.5 times the design pressure for ten minutes as required by ASME B31.1 and B31.3 codes. A
hydrostatic test certificate is also available as an accessory. See Test Certificates, Form 1254.

Form 912 sorinc.com


54/60 Registered Quality System to ISO 9001:2008 913-888-2630
Mechanical
Level Switches MC and TC Options
702A-AIC-B-A1-MC-CRTT
Manual Check (MC) and Tru-Check (TC) options permit manual actuation of vertical displacer level
switches, addressing EPA and OSHA safety requirements. The standard 30-foot stainless steel
chain allows manual actuation from the tank base, eliminating potentially hazardous trips to the top
of the tank. Specify either an MC or TC option by placing the designator in the accessory section of
the model number.

Designator Application
TC Tanks or vessels pressurized to 100 psi
MC Atmospheric vented tanks or vessels

These options are available on SOR level switch Series 701 through 704 and 730 through 733. MC and
TC option available on carbon steel units only. Series 730 through 733 are more sensitive to both high
and low SG values. Please consult factory before ordering the MC or TC options for these models.
How It Works
Pulling the handle transfers downward motion to the actuator lever by means of the beaded
stainless steel chain. The resultant motion lifts the entire level sensing assembly which moves
the attraction sleeve and actuates the switching element to simulate a high-level condition.
Switching action for alarm, shutdown or control is verified.

Dimensions
SALES ORDER # LINE ITEM # PURCHASE ORDER #

Product Specifications
101.6 393.7
4.00 15.50
Pressure Range
TC (Tru-Check) *0 to 100 psi
MC (Manual Check) 0 psi (vented to atmosphere)

W *Maximum pressure for entire level sensing assembly


*456.4
17.97 is 100 psi with Tru-Check installed.

229.4
9.03 Temperature Range -40 to 300°F (–40 to 150°C)
Wetted Parts
Ball Chrome Plated Brass
PROCESS
CONNECTION
Seal Teflon
2-1/2 NPTM OR
4" 150# FLANGE Spring 146.1 Spring Steel
* MINIMUM OVERHEAD CLEARANCE
(NOT SHOWN) 5.75
Body 1018COVER
REQUIRED TO REMOVE HOUSING Steel
ELECTRICAL
CUSTOMER Design and specifications are subject to change
CONNECTION "W" without notice.
SPECIFIED
DIMENSION
For latest revision, see www.sorinc.com.
14685 W 105TH ST LENEXA, KS 66215 USA
913-888-2630
316 SST ISO-9001 SORINC.COM
CABLE HANDLE DRAWN BY

K MITCHELL
PRODUCT CERTIFICATION DRAWING CHECKED BY
ALL DIMENSIONS ARE ±1/16 IN
M SMITH
UNLESS OTHERWISE SPECIFIED ENGINEER APPROVAL
MM
LINEAR = J FIFE
IN
DATE

DISPLACER 16 MAY 2011


THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SOR.
NO USE WHATSOEVER OF THE INFORMATION CONTAINED
HEREON, NOR REPRODUCTION IN WHOLE OR PART MAY BE
MADE WITHOUT THE EXPRESS WRITTEN PERMISSION OF SOR.
TITLE

DIM DWG 700 SERIES W/MANUAL CHECK


DRAWING NUMBER REV
EO NUMBER: 5116
0390674 3
Drawing 0390674 SCALE: 0.20
SHEET 1 OF 1
DWG SIZE

DO NOT SCALE PRINT B


74.ASSEM/1/5+
sorinc.com Form
Reset 912
Form

913-888-2630 Registered Quality System to ISO 9001:2008 55/60


Mechanical
Level Switches ASTM Material Designations

SOR uses all ASTM grade materials in the construction of mechanical level switches. The following chart
lists the specific ASTM (or UNS) materials that are normally used for each component in our switches.
Consult the factory if you do not see the specific material required for your application.
ANSI B36.10 ANSI B16.9 ANSI B36.10 ANSI B16.5
Temperature
Material Seamless Butt Weld Screwed/Socket
Flanges Range
Pipe Fitting Fitting
Carbon Steel A106B A234-WPB A105 A105 -20°F to 800°F
304/304LSS 2
A312-T304 A403-WP304 A182-F304 A182-F304 -425°F to 750°F
316/316LSS A312-T316 A403-WP316 A182-F316 A182-F316 -325°F to 750°F
Low Temperature 2

A333 Gr. 6 A420-WPL6 A350-LF2 A350-LF2 -50°F to 700°F


Carbon Steel
1-1/4% Chrome2
A335-P11 A234-WPL11 A182-F11 A182-F11 -20°F to 1100°F
1/2% Moly
Hastelloy-C2762
B6221 B366/B564 B366/B564 B366/B564 -325°F to 800°F
N10276
Alloy-202
B4641 B366/B962 B366/B462 B366/B462 -325°F to 800°F
N08020
Monel 4002
B-1651 B366/B564 B366/B564 B366/B564 -325°F to 900°F
N04400
Duplex SS2 A-790 A-815 A182-F51 A182-F51 -60°F to 600°F
2-1/4% Chrome 2

A335-P22 A335-P22 A182-F22 A182-F22 -20°F to 1100°F


1% Moly
9% Chrome
1% Moly A335-P91 A234-WP91 A182-F91 A182-F91 -20°F to 1200°F
Vanadium

Notes
1. UNS numbers are given in parenthesis for special alloys.
2. These materials are available by special order only.

Flange Face Finishes


The most common flange face finishes are shown. SOR standard flange finishes are
highlighted.
Raised Face Flanges (RF)
All raised-face flange finishes are given as a range. AARH (Average Arithmetic Root Height) values are
given with their metric equivalent.

AARH (µin.) 1000-2000 500-1000 250-500 125-250 63-125 32-63 16-32


Ra (µm) 25-50 12.5-25 6.3-12.5 3.2-6.3 1.6-3.2 0.8-1.6 0.4-0.8

Ring Tight Joint Flanges (RTJ)


The side surfaces of RTJ gasket surfaces shall not exceed 63µ” (1.6µm) roughness per ANSI B16.5.

Form 912 sorinc.com


56/60 Registered Quality System to ISO 9001:2008 913-888-2630
Mechanical
Level Switches Specific Gravity of Water

The specific gravity of water changes depending on its temperature and pressure. The chart below
lists properties of saturated steam. Saturated steam is the state where water is in transition between
liquid and vapor. The chart provides the process temperature with the associated pressure and spe-
cific gravity of the condensate water. If a water application has a high temperature and low pressure,
condensate will only be present at the temperature that corresponds to the maximum pressure.
Select the proper row based on the temperature and pressure, and read the specific gravity.
Figures are based on saturated steam.

Boiling Boiling Boiling


Vacuum Specific Pressure Specific Pressure Specific
Temperature Temperature Temperature
Inches Hg Gravity psig Gravity psig Gravity
F° F° F°
32 29.74 .9999 212 0.0 .96 450 407.0 .82
40 29.67 1.0000 220 2.49 .96 460 451.2 .81
50 29.56 .9997 230 6.08 .95 470 498.8 .80
60 29.40 .9990 240 10.27 .95 480 550.1 .80
70 29.18 .9980 250 15.13 .94 490 605.2 .79
80 28.89 .9966 260 20.14 .94 500 664.3 .78
90 28.50 .9950 270 27.17 .93 510 728.3 .77
100 27.99 .9931 280 34.52 .93 520 795.3 .76
110 27.33 .9909 290 42.87 .92 530 868.3 .76
120 26.48 .9886 300 52.30 .92 540 945.3 .74
130 25.40 .9860 310 63.00 .91 550 1028.3 .73
140 24.04 .9832 320 75.00 .91 560 1116.3 .71
150 22.35 .9803 330 89.3 .91 570 1209.3 .70
160 20.27 .9772 340 103.3 .90 580 1308.3 .69
170 17.72 .9730 350 119.9 .89 590 1414.3 .68
180 14.63 .9704 360 138.3 .88 600 1529.3 .67
190 10.91 .9668 370 158.5 .88 610 1644.3 .66
200 6.46 .9631 380 180.9 .87 620 1769.3 .65
210 1.17 .9592 390 205.4 .86 630 1902.3 .63
400 232.3 .86 640 2042.3 .62
410 261.6 .85 650 2190.3 .60
420 293.4 .84 660 2346.3 .58
430 328.4 .84 670 2511.3 .56
440 366.2 .83 680 2690 .49
690 2883 .48
700 3075 .44
705 3189 .32

sorinc.com Form 912


913-888-2630 Registered Quality System to ISO 9001:2008 57/60
Mechanical
Level Switches Conversions

General English-to-Metric unit conversions are listed below.

Pressure
To Convert from: To: Use this formula:
Bar Pounds per Square Inch (psi) bar x 14.504 = psi
Kilo Pascals (kPa) Pounds per Square Inch (psi) kPa x 0.145 = psi
Mega Pascals (MPa) Pounds per Square Inch (psi) MPa x 145 = psi
Kilograms per cm2 (kg/cm2) Pounds per Square Inch (psi) kg/cm2 x 14.223 = psi
Pounds per Square Inch (psi) Bar psi ÷ 14.504 = bar
Pounds per Square Inch (psi) Kilo Pascals (kPa) psi ÷ 0.145 = kPa
Pounds per Square Inch (psi) Mega Pascals (MPa) psi ÷ 145 = MPa
Pounds per Square Inch (psi) Kilograms per cm2 (kg/cm2) psi ÷ 14.223 = kg/cm2

Specific Gravity
To Convert from: To: Use this formula:
Kilograms per meter3 (kg/m3) Specific Gravity (SG) kg/m3 x 0.001 = SG
Pounds per foot3 (lb/ft3) Specific Gravity (SG) lb/ft3 ÷ 62.4 = SG
Degrees API Specific Gravity (SG) 141.5 ÷ (API +131.5) = SG
Specific Gravity (SG) Kilograms per meter3 (kg/m3) SG x 1000 = kg/m3
Specific Gravity (SG) Pounds per foot3 (lb/ft3) SG x 62.4 = lb/ft3
Specific Gravity (SG) Degrees API (141.5 ÷ SG) - 131.5 = API

Length
To Convert from: To: Use this formula:
millimeters (mm) Inches (in.) mm ÷ 25.4 = in.
meters (m) Feet (ft.) m x 3.281 = ft.
Inches (in.) millimeters (mm) in. x 25.4 = mm
Feet (ft.) meters (m) ft. ÷ 3.281 =m

Temperature
To Convert from: To: Use this formula:
Degrees Fahrenheit (°F) Degrees Centigrade (°C) (°F - 32) ÷ 1.8 = °C
Degrees Centigrade (°C) Degrees Fahrenheit (°F) (1.8 x °C) + 32 = °F

Fluid Flow Rates


To Convert from: To: Use this formula:
Feet per Second (FPS) Gallons per Minute (GPM) FPS x 448.83 x A1 = GPM
Kilograms per Hour (kg/H) Gallons per Minute (GPM) (kg/H ÷ kg/m3) x 4.403 = GPM
Meters per Second (m/s) Gallons per Minute (GPM) m/s x A2 x 15,852 = GPM
Cubic meters per Hour (m3/hr) Gallons per Minute (GPM) m3/hr ÷ 0.2271 = GPM
Gallons per Minute (GPM) Feet per Second (FPS) GPM ÷ (448.83 x A1) = FPS
Gallons per Minute (GPM) Kilograms per Hour (kg/H) GPM x kg/m3 ÷ 4.403 = kg/H
Gallons per Minute (GPM) Meters per Second (m/s) GPM ÷ (A2 x 15,852) = m/s
Gallons per Minute (GPM) Cubic meters per Hour (m3/hr) GPM ÷ 4.4 = m3/hr

Variables:
A1 = Area of pipe in square feet (ft2)
A2 = Area of pipe in square meters (m2)
kg/m3 = Specific gravity in kilograms/cubic meter

Form 912 sorinc.com


58/60 Registered Quality System to ISO 9001:2008 913-888-2630
Mechanical
Level Switches Weights
The approximate shipping weights shown below are for standard models. Weights will vary based
on pipe size, length and flange size. Consult the factory for the weight of a specific unit.

Floats Displacers
Model pounds kilograms Page Model pounds kilograms Page
101* 55 25 12 701 18 8.5 36
102* 80 37 12 702 18 8.5 36
103* 130 60 12 703 30 13.5 36
108 130 59 21 704 30 13.5 36
109* 125 53 12 705 20 9 36
121* 40 18 12 706 30 9 36
122* 50 23 12 707 32 14.5 36
123* 80 36 12 708 32 14.5 36
124* 90 42 12 730 20 9 39
201* 45 20.5 17 731 20 9 39
202* 26 12 17 732 32 14.5 39
203* 26 12 17 733 32 14.5 39
204* 26 12 17 734 22 10 39
205* 45 20.5 17 735 22 10 39
206* 45 20.5 17 736 34 15.5 39
207* 45 20.5 17 737 34 15.5 39
208 89 22 17 740* 28 12.5 33
209* 62 29 17 741* 48 22 29
221* 22 10 17 742* 60 27 29
301 12 5.5 23 743* 68 31 29
303 12 5.5 23 750 24 11 43
304 12 5.5 23 751 24 11 43
401 15 7 26 752 36 16 43
402 12 5.5 26 753 36 16 43
403 28 12.5 26 754 26 12 43
404 15 7 26 755 26 12 43
405 12 19 26 756 38 17 43
406 70 32 26 757 38 17 43
801* 115 51 29
802 185 82 29
803* 35 16 33
804 50 22.5 33
*Add weights from the table below to the base model weight for VV, VVT, or VH configurations
with flanges.

VV, VVT and VH Additional Weights


150# 300# 600#
Size
pounds kilograms pounds kilograms pounds kilograms
1” 5 2.5 8 4 9 4.5
1-1/2” 8 4 15 7 15 7
2” 12 5.5 16 7.5 18 8.5

Weights shown in this table include two flanges, pipe nipples, and fittings.
Note: Consult the factory for additional weight due to accessories or non-standard requirements.
sorinc.com Form 912
913-888-2630 Registered Quality System to ISO 9001:2008 59/60
SOR offers a full line of commercial-grade process instruments.
®

echOsonix ®

Level Transmitters

Pressure
Temperature
Flow
Switches
Level
Switches

Level Temperature
Switches

Flow

Pressure
Switches

Process Instrumentation

We Deliver Quality On Time

SOR Inc. SOR Europe, Ltd. SOR - China


14685 West 105th Street Farren Court Room 903, No. 10 Building
Lenexa, Kansas 66215 Cowfold Wan Da Plaza
West Sussex RH13 8BP No. 93 Jian Guo Road
Phone 913-888-2630 United Kingdom Chao Yang District
Toll Free 800-676-6794 Beijing, China 100022
Fax 913-888-0767 Phone +44 (0) 1403 864000
Fax +44 (0) 1403 864040 Phone +86 (10) 5820 8767
sorinc.com Fax +86 (10) 58 20 8770

Registered
Form 912 Quality System to ISO 9001:2008 sorinc.com
Form 912 (07.11) ©2011 SOR Inc.
60/60 Registered Quality System to ISO 9001:2008 913-888-2630