You are on page 1of 7

circular tube SHORT circular COLUMN DESIGN

dia of outer = 1050 mm


inner dia = 1000 mm D = 1000 mm
stress = 217 MN/M^2 FCK = 70 N/mm2
area = 80503.31 mm2 FY = 500 N/mm2
P = 17469.2 KN
AG = 785398.2 mm2
ASC = 31415.93 mm2

AC = AG - ASC
= 753982.2

P = 0.4FCK AC+0.67 FY ASC


= 31635838 N
P = 31635.8 KN

total load capacity = 49105.1 KN


4%
AREA OF STEEL 31415.93
circular tube SHORT circular COLUMN DESIGN

dia of outer = 1060 mm


inner dia = 1000 mm D = 1000
stress = 300 MN/M^2 FCK = 70
area = 97075.21 mm2 FY = 500
P = 29122.6 KN
AG = 785398.2
ASC = 31415.93

AC = AG - ASC
= 753982.2

P = 0.4FCK AC+0.67 FY ASC


= 31635838
P = 31635.8

total load capacity = 60758.4 KN


UMN DESIGN

mm
N/mm2
N/mm2

mm2 4%
mm2 AREA OF STEEL 31415.93

0.4FCK AC+0.67 FY ASC


N
KN