You are on page 1of 82

RHEEM THERMAL

MECHANICAL AND PROCESS WATER HEATING & CHILLING

HIGH AMBIENT HOT WATER

HIGH TEMPERATURE HOT WATER

HOT WATER TO CHILLED WATER

HYDRONIC HEATING

AQUACULTURE

POOL AND SPA HEATING


Materials and data subject to change without notice due to ongoing product improvements.
Rheem Thermal, Accent Air and Raypak are divisions of Rheem Australia Pty Ltd.

HEAD OFFICE

Rheem Thermal Systems Group


21 Atkinson Street, Liverpool,
New South Wales, 2170 Australia
Sales: 1300 132 950
Service: 02 8706 8400
Intl: +61 2 8706 8400
Email: sales@rheemthermal.com.au
Web: www.rheemthermal.com.au
DA_RTSG_08/16
1

ABN: 21 098 823 511


RHEEM THERMAL SYSTEMS GROUP INSTALL A
WHY CHOOSE RHEEM THERMAL?

There are many critically important reasons as to why you should choose Rheem Thermal to
UNDERSTANDING assist you with your water heating needs.

HOT WATER IS WHAT


But these can be condensed to one simple element - trust.
RHEEM DOES BEST You can trust that you will receive quality product that is supported by one of Australia’s most recognised and respected brands,
which has served the Australian market since 1939. Rheem in turn is owned by Paloma, the world’s largest hot water company.

Rheem is the premier commercial water heater company in Australia. You can trust that the product design meets all Australian Standards. It will be fully compliant for electrical safety.
Our reputation is built on a trust we have developed with specifiers, installers
and users in over 40 years of servicing the commercial water heating industry. You can trust that the product has been designed to work at optimal efficiency in your application and in your climate. For heat
pumps, Rheem has a full psychrometric test laboratory where we are able to develop our designs in controlled conditions from
Rheem’s Commercial and Industrial product range is extensive and covers Solar and Heat Pump, Gas Storage and -10°C to 50°C ambient.
Continuous Flow, Raypak Hot Water, Boiling Water and Electric and Warm Water.
You can trust that we do not have a one size fits all mentality.

You can trust that we have designed and manufactured the product to achieve benchmark minimum performance standards. Our
Rheem Thermal Systems Group product represents the best that we can do. We could build product more cheaply but we won’t. Our over-riding commitment is to
Specialist solutions for niche markets efficiency, robustness, compliance and safety.

Rheem’s Thermal Systems Group is a newly created specialist arm of the broader Rheem business. The Group represents an You can trust where the product comes from.
exciting mix of innovative gas and electric heat pump hot water technology, focusing on niche markets. The Group comprises the
Raypak and Accent Divisions of Rheem and reflects a combined sixty years of local market experience and product excellence. We manufacture our Raypak gas heaters in Melbourne and our Accent heat pumps in Sydney.
These companies have routinely undertaken some of Australia’s and Asia’s most high profile and bespoke projects and the merg-
ing of the unique skill sets and technology expertise under the Rheem Thermal banner will see a further extension of the combined You can talk to us before your heater is built. We will learn your application and help ensure that the end product achieves your
focus on high efficiency and innovative hot water solutions. target outcomes. In many cases, we will have the option to modify the product and customize its build to the specific needs of
your project.
Both Accent and Raypak are specialist manufacturers with their production facilities being in Sydney and Melbourne respectively.
While the companies have a long history in the Australian market, the Accent and Raypak products likewise have an equally strong You can trust that in the event that the product needs technical or service support that we will be here for the long haul. We will
international record as evidenced by projects such as the heating and cooling of the Bangkok Aquatic Centre for the Asian Games have expert product designers on hand, factory technicians and the long-established service network that you would expect from
undertaken in 1998. Today, the development of international markets is a key focus of the Rheem Thermal Group and its product companies with a combined 60+ years specialization in gas and heat pump water heating.
base includes high ambient, hot water heat pump technology, specifically-designed and developed using the Research and
Development excellence of Rheem for the Asian market.

TM

AS 3498
Lic WMKA 00153
Lic WMKA 00177
Lic WMKA 00299
Lic WMKA 00500
Lic WMKA 21434
Lic WMKA 21549
Australian Quality Lic WMKA 21766
SAI Global
Standard ISO 9001
AS/NZS 2712
Lic SMK 0757
Lic SMK 1048
Lic SMKP 21548
SAI Global

rheemthermal.com.au 1
CONTENTS

4-5 Rheem Thermal Range

6 Rheem Thermal Systems Group Range of Products pages

8 Mechanical and Process Water Heating and Chilling

10 High Temperature Hot Water

12 Hot Water to Chilled Water

14 Hydronic Heating

16 Aquaculture Water Heating and Chilling

18 Residential Pool and Spa Gas and Heat Pump Heating

20 Commercial and Aquatic Centre Pool Heating

22 Elite Sports

24 Dehumidifiers

26 Rheem IQ ®

27 Case Study 1

28 Case Study 2

29 Case Study 3

30 Case Study 4

31 Case Study 5

32 Case Study 6

33 Case Study 7 & 8

34 Case Study 9

35 Case Study 10, 11 & 12

36 Installation Schematics

37 Clearances
Rheem Thermal heating and cooling systems feature in some of Australia and Asia’s most prestigious projects:
From top: Sydney Opera House; Harbourview Hotel, Macau; Houn Salmon; Macua Harbour, Sydney Cricket Ground.

2 rheemthermal.com.au 3
THE RHEEM THERMAL RANGE

Air-to-Water Heat Pumps: large office buildings and supermarkets synonymous with the heating of Design Options Include: 1980. This process can be repeated
to more diverse uses in manufacturing, Australian pools and spas. In a market to be provided with a double dipped
The Accent Air-to-Water heat pump mining and primary industry. Mechanical obsessed with lowest cost, these brands Heating Only Units: coil. Copper Fins on Copper Coil: In
transfers heat from air, providing the hot and chilled water is typically supplied continue to reflect a commitment to corrosive environments the aluminium
advantages of a solar heater without the to fan coils for space heating and cooling quality, performance and true value. The heating only heat pump provides fins will show the first sign of corrosion
need for direct solar gain to a collector. while process needs are more often high efficiency water heating, giving to the evaporator. The use of copper fins
While the rate of transfer is highest on direct water uses. Commercial and Aquatic Centre Pool maximum operating cost reduction and provides the ultimate protection.
warm days, heat gain is even made Heating: reliability.
in sub zero temperatures or overnight High Ambient Hot Water Heating:
providing the potential for year round Rheem is clearly the Australian market Heating & Cooling: Unit Construction:
heating. The Accent heat pump technology lends leader in the heating of large pools.
itself perfectly to Asian markets where the The reverse cycle heat pump provides Marine grade aluminium, stainless steel
Ground-Sourced Heat Pumps: high air temperatures and high humidity Both the Accent and Raypak brands are water heating and cooling. This unique or zinc annealed powder coated cabinets
translates to water heating at very high internationally-recognised in this field. ability is used in a variety of applications are available.
The ground absorbs nearly half the efficiency. The region’s most prestigious projects but most commonly for space
thermal energy reaching the earth from are included in a proud history including conditioning and comfort control in Horizontal discharge design or remote
the sun. The Accent heat pump can High Temperature Hot Water: heating and cooling for the Pan Pacs, buildings and homes via the provision discharge fans are available on models
harness this energy for both heating Commonwealth Games, Asian Games of cooled or heated water to fan coils or up to 100kW output. Horizontal discharge
and cooling by a ground loop. As the Accent’s specialist focus and research and Pacific Games. floor coils. This design is also commonly models can be stacked to reduce plant
ground remains at a relatively constant capability means that it can offer high used in aquaculture and for pool heating foot print or enable installation in low
temperature, the heat pump operates at efficiency heat pump hot water up to Elite Sports: and cooling. head height building overhang areas.
stable high efficiency. 65°C leaving water temperature.
Virtually all of Australia’s major stadiums Chilling only: Units can also be made to connect to
Water-to-Water Heat Pumps: Hot Water to Chilled Water: include Accent elite sports range of ducting for internal installations by the
heater/chillers. In water-to-water design, As a chiller, the unit provides cold water use of high static fans. Ducted models
Like the ground, water provides a Often coupled to a building’s chilled these units simultaneously provide for applications as diverse as pond are designed to discharge the cold air
relatively constant heat source. Water water ring main, this water-to-water type heating and chilling to separate recovery temperature maintenance for aquaculture outside of the plant room.
sources can vary from ground water to heat pump series achieves benchmark ice baths and hot spas. Alternatively, through to chilled water coils for air
lakes, streams and even the ocean. The levels of energy efficiency by providing Accent’s air-to-water units can be conditioning systems.
water-to-water unit is compact, quiet and the dual functions of hot and chilled water dedicated heaters or chillers or reverse Specialist Treatments
harnesses nature’s energy for hot water supply. cycle for water temperatures between Twin Heat Exchanger: for Noise Sensitive
and swimming pool heating. 8°C to 40°C. Environments:
Hydronic Heating: The twin heat exchanger model provides
Direct connection and Closed Loop Dehumidification: automated heating between two Accent offers various options in fan
Natural Gas and Propane Pool Typically providing hot water at mid range separate tasks from the single unit. selection making the unit the quietest
Heaters: temperatures for home and building The Accent DH Series is designed for Most commonly, this approach provides heat pump available. This includes the
comfort heating via either a hydronic the control of relative humidity in indoor efficient split temperature heating use of larger blade fans at low speed or
Raypak has been the world’s leading loop or radiators, this range of high spaces and particularly, for residential or between pool and spa. unit design including axi-top fans. Other
manufacturer of copper finned boilers for efficiency heat pumps has also been commercial indoor swimming pools. specific acoustic treatments are available
over fifty years. We have sold the Raypak used in primary industry applications Plunge Pool: such as compressor jackets, added case
gas pool and spa heater in Australia such as piggeries, poultry farming and lining and hoods. Specialist acoustic
since 1969 and began local manufacture greenhouses. Project Driven: The Accent heat pump can uniquely louvres on air intake and pods for air
under licence in 1983. This atmospheric provide cooling to one application while discharge are also used where required
product has been the tradesman’s Aquaculture Water Heating and In addition to standard product, Accent rejecting heat to another. This is most on larger capacity systems.
choice for decades because of the Chilling: has the ability to custom-design commonly used for resorts, day spas
simplicity of design and reliability of and manufacture its heat pumps to and sports training centres to provide
operation. Aquaculture (aqua farming) is another meet specific project needs. This hot and cold plunge pools. All Weather Performance:
specialist niche for Rheem Thermal manufacturing flexibility, range of design
product. Our client base extends from options and the willingness of its skilled Automatic defrost either by hot gas by-
Rheem Thermal’s Major Areas market leading commercial operators design team to work with consultants Specialist Treatments for pass or reverse cycle de-ice is standard
of Market Application are: to government research facilities in and end clients in application evaluation Corrosive Environments/ on every Accent heat pump. Accent’s
Australia and internationally and with a and design sees it produce project- Anti-Corrosion Evaporator advanced de-ice control allows the heat
Mechanical and Process Water range of seafood extending from kingfish driven results and benchmark outcomes Treatments: pump to continue performing in low
Heating and Chilling: to lobster, from barramundi to abalone. in energy efficiency, which form the ambient temperature conditions.
foundation of its market reputation and The standard coil is treated with Rheem
The Accent high efficiency heat pump is Residential Pool and Spa Gas and success. Cote™ anti corrosion treatment. This
used to provide electrically-generated Heat Pump Heating: is a total immersion coating and has
low cost hot water in many specialist been tested and exceeded a 5000
applications, ranging from hospitals, The Accent and Raypak brands are hours salt spray test to AS 2331.32 –

4 rheemthermal.com.au 5
MECHANICAL AND PROCESS
WATER HEATING AND CHILLING

High Efficiency Heat Pump Water Heating Hot Water (HW) Series - Air-to-Water type
Max.
The name Rheem is clearly synonymous with water heating. Rheem is a global brand and would be best known for residential gas FLA Rated Load
Leaving Min CB Heating
Water
Weight
Dimensions (mm)
storage and continuous flow hot water heaters. But with a product range which includes the Accent heat pump, Rheem Thermal’s MODEL Electrical (Full Load Amps 10°C
Water size kW
Power COP Airflow L/S Flowrate
(kg)
Length x Width x
Amps) SST / 51°SCT L/S Height
focus is on providing high thermal efficiency with hot water across a broad spectrum of commercial and industrial applications. temp. °C
HW13.5-1 1 Ph/240V/50Hz 18.6 13.5 61 25 13.6 2.9 4.8 680 0.5 80 1000 x 475 x 1150
Capability HW23-1 1 Ph/240V/50Hz 27.3 20.7 61 32 23.4 5.1 4.6 1600 0.9 110 1150 x 565 x 980
HW23-3 3 Ph/415V/50Hz 12.5 9.6 61 16 23.6 5.0 4.7 1600 0.9 110 1150 x 565 x 980
The Accent product range suits small commercial through to large-scale industrial uses, with a broad capacity spread and the HW27-3 3 Ph/415V/50Hz 16.0 12.7 61 20 27.3 6.0 4.5 2500 1.1 120 1450 x 700 x 825
capability to provide hot water up to 61°C (HW Series), chill to 8°C (CH Series) or to provide reverse cycle functionality, using HW37-3 3 Ph/415V/50Hz 19.0 15.5 61 25 37.0 7.6 4.9 2500 1.5 170 1750 x 800 x 825
Refrigerant R407c. Typically, these units operate at a temperature differential of around 6°K but the hydraulic layout of the unit can HW50-3 3 Ph/415V/50Hz 24.2 19.0 61 40 49.6 10.6 4.7 4700 2.0 240 1750 x 800 x 1015
be altered to allow for higher temperature rise at a lower water flow rate. HW64-3 3 Ph/415V/50Hz 33.6 27.7 61 40 64.0 13.9 4.6 4700 2.6 260 1750 x 800 x 1215
HW86 3 Ph/415V/50Hz 41.6 32.6 61 50 86.7 17.8 4.9 4700 3.4 430 1900 x 1000 x 1215
The units are of both air-to-water and water-to-water type. In air-to-water design, the operating condition (ambient) range is -8°C to HW99-3 3 Ph/415V/50Hz 47.0 36.6 61 60 99.3 20.6 4.8 7335 3.9 800 2210 x 1610 x 2020
45°C. In water-to-water type, the minimum entering water temperature on the secondary side is 8°C, with a maximum leaving water HW128-3 3 Ph/415V/50Hz 67.2 55.4 61 80 128.0 27.8 4.6 9400 5.1 820 2200 x 1610 X 2270
temperature on the primary side of 61°C. HW149-3 3 Ph/415V/50Hz 72.8 57.0 61 80 148.9 31.7 4.7 14100 5.9 1200 3462 x 1610 x 2290
HW192-3 3 Ph/415V/50Hz 103.2 85.5 61 120 192.0 42.9 4.5 18800 7.6 1300 3462 x 1610 x 2290
Efficiency HW256-3 3 Ph/415V/50Hz 134.4 110.8 61 150 256.0 55.6 4.6 18800 10.2 1700 3462 x 1962 x 2290
HW340-3 3 Ph/415V/50Hz 163.7 127.1 61 180 339.9 74.9 4.5 29300 13.5 2050 3462 x 1962 x 2290
Fine tuning of system performance in our world class psychrometric test facility has led to co-efficients of performance of up to 4.9
Design conditions Hot side 39°C water inlet
inlet, 45°C water outlet @ 51°C SCT,
SCT 20°C Ambient,
Ambient 60% RH @ 10°C SST.
SST
at nominal conditions, with higher efficiencies leading directly to reduced energy consumption, lowered demand and improved
recovery rates.
Hot Water (HWC) Series – Water-to-Water type
Range FLA Rated Load
Max Min CB Heating Heating Heating
Heating
Cooling Cooling Cooling
Cooling
Combined
Model Voltage (Full Load Amps 2°C
LWT °C size kW Power COP
Water
kW Power COP
Water
COP
Amps) SST / 51°SCT Flowrate L/S Flowrate L/S
The range is extensive and diverse and ranges from single compressor models at 14KW nominal output to quad compressor
HWC23 3 Ph/380-
models up to 340kW. Technical data for a cross-section of the range is given on the following page. Contact would be welcomed on 10.7 8.3 61 16 17.3 4.7 3.7 0.7 12.6 4.7 2.7 0.6 6.4
415V/50Hz
other capacity and design configuration options. HWC27 3 Ph/380-
13.2 10.3 61 20 21.1 5.4 3.9 0.8 15.7 5.4 2.9 0.8 6.8
415V/50Hz
Extra Features HWC37 3 Ph/380-
16.6 13.1 61 20 29.1 7.0 4.1 1.2 22.1 7.0 3.1 1.1 7.3
415V/50Hz
Fully upgradable to Rheem IQ® tariff intelligent control and BMS interface. Capable of compressor staging with optional power HWC49 3 Ph/380-
21.8 16.6 61 25 38.9 9.3 4.2 1.6 29.5 9.3 3.2 1.4 7.3
415V/50Hz
factor correction.
HWC64 3 Ph/380-
31.2 25.2 61 40 50.1 12.6 4.0 2.0 37.5 12.6 3.0 1.8 7.0
415V/50Hz
HWC85 3 Ph/380-
DIMENSIONAL 37.9 28.2 61 50 66.6 16.6 4.0 2.6 50.0 16.6 3.0 2.4 7.0
415V/50Hz
DRAWING OF HWC98 3 Ph/380-
ACCENT MODEL 43.6 33.1 61 50 77.8 18.7 4.2 3.1 59.1 18.7 3.2 2.8 7.3
415V/50Hz
HW340 HWC128 3 Ph/380-
62.4 50.4 61 80 100.2 25.2 4.0 4.0 75.0 25.2 3.0 3.6 7.0
415V/50Hz
HWC149 3 Ph/380-
65.4 49.7 61 80 116.6 28.0 4.2 4.7 88.6 28.0 3.2 4.2 7.3
415V/50Hz
HWC192 3 Ph/380-
93.6 75.7 61 100 150.3 37.8 4.0 6.0 112.5 37.8 3.0 5.4 7.0
415V/50Hz
HWC256 3 Ph/380-
124.8 100.9 61 150 200.4 50.4 4.0 8.0 150.1 50.4 3.0 7.2 7.0
415V/50Hz
HWC340 3 Ph/380-
151.6 112.6 61 160 266.3 66.2 4.0 10.4 200.1 66.2 3.0 9.6 7.0
415V/50Hz

Design conditions Hot side 39°C water inlet SCT Cold side 12°C water inlet,
inlet, 45°C water outlet and 51°C SCT, inlet 7°C water outlet and 2°C SST.
SST

Government Offices
Offices, Anne St
St, Brisbane - 300kW building loop heating

6 rheemthermal.com.au 7
HIGH AMBIENT HOT WATER

Hot Water for high volume users in Asia High ambient hot water heat pumps - R407c Models for 61°C water

The Accent HA Series has been specifically designed to provide hot water for large volume users in Asian markets. The high Rated Load Max.Leaving Water
FLA (Full Min CB Heating Weight Dimensions (mm) Length
temperatures and high humidity so characteristic of much of Asia provides a perfect setting for high efficiency heat pumps to Model Load Amps)
Amps 12°C Water temp.
size kW
Power COP Airflow L/S Flowrate
(kg) x Width x Height
SST / 51°SCT °C L/S
produce hot water. This warmth provides a constant heat source for a heat pump, which extracts this heat and converts this to water
heating at high efficiency, lowering electrical usage and demand. HW25HA-3HG 12.5 9.6 61 20 25.4 5.0 5.1 1600 1.01 100 1150 x 565 x 980
HW30HA-3HG 16.0 12.8 61 20 29.1 6.0 4.8 2300 1.16 120 1150 x 565 x 980
Capability HW40HA-3HG 19.0 15.5 61 25 39.4 7.6 5.2 2300 1.57 170 1750 x 800 x 825
HW50HA-3HG 24.2 19.0 61 40 52.6 10.6 5.0 4700 2.09 290 1800 x 800 x 1220
The Accent High Ambient (HA) range includes two series, units using R407c for hot water heating up to 61°C and R134a for heating HW65HA-3HG 33.6 27.7 61 63 68.0 13.9 4.9 4700 2.71 300 1800 x 800 x 1220
up to 65°C. Given the warm, moist ambient temperatures of the intended tropical locales for installation, the standard design of HW80HA-3HG 35.6 28.6 61 63 78.7 15.3 5.1 4700 3.13 400 1750 x 1175 x 1215
the HA units excludes a de-ice capacity and is recommended for a minimum operating ambient of 15°CDB. But recognising that HW105HA-3HG 47.0 36.6 61 63 105.3 20.7 5.1 7335 4.19 600 2210 x 1175 x 1300
countries such as Hong Kong can see low overnight temperatures, the addition of hot gas de-ice is provided as an option. The HW135HA-3HG 65.8 54.0 61 80 136.0 27.3 5.0 7335 5.41 650 2210 x 1175 x 1300
designation (HG) indicates that hot gas deice is fitted and the minimum operating ambient lowers to -5°C.

Efficiency High ambient hot water heat pumps - R134a models for 65°C water

Rated Load Max.Leaving Water


Dedicated product development for the Asian market, with the tropical conditions replicated in Rheem’s world class psychrometric Model
FLA (Full
Amps 12°C Water temp.
Min CB Heating
Power COP Airflow L/S Flowrate
Weight Dimensions (mm) Length
test facility has led to co-efficients of performance of up to 5.2, with higher efficiencies leading directly to reduced energy Load Amps) size kW (kg) x Width x Height
SST / 51°SCT °C L/S
consumption, lowered demand and improved recovery rates.
HW20DHA-3HG 12.8 9.6 65 20 20.4 4.1 5.0 1600 0.80 100 1150 x 565 x 980
HW35DHA-3HG 20.2 14.5 65 32 35.0 7.0 5.0 2300 1.40 170 1750 x 800 x 825
Range
HW48DHA-3HG 27.9 23.9 65 40 47.6 10.1 4.7 4700 1.90 300 1800 x 800 x 1220
HW62DHA-3HG 31.1 24.1 65 40 62.0 12.8 4.9 4700 2.47 400 2050 x 800 x 1510
The range is extensive and diverse and ranges from single compressor models at 20KW nominal output (heating) to dual
HW124DHA-3HG 60.8 46.8 65 80 124.0 25.0 5.0 7335 4.93 650 2200 x 1400 x 1330
compressor models up to 136kW. Technical data for a cross-section of the range is given on the following page. Contact would be
welcomed on other capacity and design configuration options. Design conditions - 39°C EWT, 45°C LWT @51°SCT, 30°C Ambient, 60% RH @ 10°C SST
Power supply 380 -415V / 50 Hz / 3 phase
Extra Features The above models are also available without de-ice capabilty for temperate locations (recommended minimum ambient of 15°C DB)

Purpose designed refrigeration system for high ambient locations. Full commercial construction with marine grade aluminium
case and Rheem Cote® anti-corrosion treatment of evaporators. Digital controls and upgradable to Rheem IQ® including BMS
connectivity. Available with or without deice capacity (hot gas injection).

DIMENSIONAL
DRAWING OF
ACCENT MODEL
HW65HA

Macua, China - location of multiple Accent heat pump installations


Macua

8 rheemthermal.com.au 9
HIGH TEMPERATURE HOT WATER

Hot Water to 65°C using R134a High Temperature Hot Water Series (DHT) - R134a models for 65°C water
Max.
Rheem’s specialist focus and research capability has it devoted to the achievement of higher water temperatures without FLA Rated Load Water Dimensions (mm)
Leaving Min CB Heating Design Airflow Weight
Model Electrical (Full Load Amps 10°C Power COP Flowrate Length x Width x
compromise to efficiency. The extension of the Accent’s heat pump’s operating range to 65°C leaving water temperature broadens Amps) SST / 51°SCT
Water temp. size kW TD L/S
L/S
(kg)
Height
°C
the application of this technology and delivers high efficiency to new segments of the hot water market.
HW20DHT-3 3 Ph/415V/50Hz 12.8 9.6 65 20 19.1 4.0 4.7 6 1600 0.8 100 1150 x 565 x 980
Capability HW90DHT-3 3 Ph/415V/50Hz 54.5 46.5 65 100 89.2 19.5 4.6 6 7335 3.6 800 2200 x 1400 x 1330
HW134DHT-3 3 Ph/415V/50Hz 83.8 71.8 65 100 133.8 30.1 4.5 6 14100 5.3 1250 3462 x 1962 x 2040
The Accent High Temperature range sees the use of Refrigerant R134a for heating up to 65°C. In their standard design, the units HW179DHT-3 3 Ph/415V/50Hz 111.8 95.7 65 150 178.3 40.1 4.5 6 18800 7.1 1500 3462 x 1962 x 2040
include deice by hot gas injection and are suitable for minimum operating ambients to -5°C. The range is capable of meeting small Design conditions - 39°C EWT, 45°C LWT @51°SCT, 30°C Ambient, 60% RH @ 10°C SST
residential needs up to the large hot water loads of commercial buildings in heating and space conditioning, with a recovery ability
of up to 4,000 litres per hour (based on a 40°C temperature rise).

Efficiency

Dedicated product development both in the field and in Rheem’s world class psychrometric test facility has led to co-efficients of
performance of between 4.7 to 5.0 at rating conditions, with higher efficiencies leading directly to reduced energy consumption,
lowered demand and improved recovery rates.

Range DIMENSIONAL DIMENSIONAL


DRAWING OF DRAWING OF
ACCENT MODEL ACCENT MODEL
The range is extensive and diverse and ranges from single compressor models at 20KW nominal output (heating) to dual HW179DHT-3
HW90DHT-3
compressor models up to 190kW. Technical data for a cross-section of the range is given on the following page. Contact would be
welcomed on other capacity and design configuration options.

Extra Features

Purpose designed refrigeration system for high ambient locations. Full commercial construction with marine grade aluminium
case and Rheem Cote® anti-corrosion treatment of evaporators. Digital controls and upgradable to Rheem IQ® including BMS
connectivity.

Vinpearl Nha Trang Resort


Resort, Vietnam - site of multiple Accent hot water and pool heaters

10 rheemthermal.com.au 11
HOT WATER TO CHILLED WATER

Ultra efficiency in hot water and chilled water supply Hot Water to Chilled Water Series (HWC) - Cold Side 20 °C EWT
FLA Rated Load Heating Cooling
The Accent HWC Series achieves unparalleled levels of energy efficiency by simultaneously providing high efficiency hot water Model Electrical (Full Load Amps 10°C
Max Min CB Heating Heating Heating
Water
Cooling Cooling Cooling
Water
Combined
LWT °C size kW Power COP kW Power COP COP
and chilling, via water-to-water heat pump design. Most commonly with the unit connected to the condenser water ring main of a Amps) SST / 51°SCT Flowrate L/S Flowrate L/S
building, the primary function is hot water heating. But with heat transfer to a storage tank, the by-product is chilled water which HWC23 3 Ph/380-
10.7 8.4 61 20 23.6 4.7 5.0 0.9 18.9 4.7 4.0 0.9 9.1
lowers load to the building chiller. 415V/50Hz
HWC27 3 Ph/380-
13.2 10.4 61 20 27.3 5.5 5.0 1.1 21.3 5.5 3.9 1.0 8.9
415V/50Hz
Capability
HWC37 3 Ph/380-
16.6 13.1 61 20 37.0 7.0 5.3 1.5 29.9 7.0 4.3 1.4 9.5
415V/50Hz
The Accent Hot Water to Chilled Water (HWC) range includes units using R407c for hot water heating up to 61°C, with a minimum HWC49 3 Ph/380-
entering water temperature on the building loop of 12°C, giving a return water temperature of 7°C. Warmer temperatures to the ring 21.8 16.6 61 25 49.6 9.4 5.3 2.0 40.3 9.4 4.3 1.9 9.6
415V/50Hz
main or water source see the heat transfer and efficiencies improve. The ambient temperature of the installation location has no HWC64 3 Ph/380-
31.2 25.3 61 40 64.0 12.7 5.0 2.6 51.3 12.7 4.0 2.5 9.1
impact on the performance of this type of plant, with the units being compact and suitable for indoor or external installation. 415V/50Hz
HWC85 3 Ph/380-
37.9 28.4 61 50 84.8 16.9 5.0 3.4 68.0 16.9 4.0 3.2 9.1
Efficiency 415V/50Hz
HWC98 3 Ph/380-
43.6 33.2 61 50 99.3 18.7 5.3 3.9 80.5 18.7 4.3 3.8 9.6
415V/50Hz
The ability of these units to provide a dual efficiency sees combined COPs of up to 9.6. The efficiency in hot water production is in
HWC128 3 Ph/380-
the range of 5.0 to 5.3 and this leads to substantial savings in energy use and heating cost. The savings are magnified where the 62.4 50.6 61 80 128.0 25.4 5.0 5.1 102.6 25.4 4.0 4.9 9.1
415V/50Hz
cooling by-product lessens a building’s chilling load. COPs in cooling are in the range of 3.9 to 4.3. HWC149 3 Ph/380-
65.4 49.8 61 80 148.9 28.1 5.3 5.9 120.8 28.1 4.3 5.8 9.6
415V/50Hz
Range HWC192 3 Ph/380-
93.6 75.9 61 100 192.0 38.1 5.0 7.7 154.0 38.1 4.0 7.4 9.1
415V/50Hz
The range is extensive and covers single compressor models between 17kW nominal HWC256 3 Ph/380-
124.8 101.2 61 150 256.0 50.8 5.0 10.2 205.3 50.8 4.0 9.8 9.1
415V/50Hz
output (heating) to quad compressor models up to 339kW. Technical data for a cross-
HWC340 3 Ph/380-
section of the range is given on the following page. Contact would be welcomed on 415V/50Hz
151.6 113.5 61 160 339.2 67.4 5.0 13.5 271.8 67.4 4.0 13.0 9.1
other capacity and design configuration options.
Design conditions Hot side 39°C water inlet
inlet, 45°C water outlet and 51°C SCT,
SCT Cold side 20°C water inlet,
inlet 15°C water outlet and 10°C SST
SST.

Extra Features
Hot Water to Chilled Water Series (HWC) - Cold Side 12°C EWT
Copper heat exchanger either side, single-wall but with optional vented design. Flow
switch protection. Multiple safeties including low temperature freeze protection on the Hong Kong - A successful market for the Accent heat pump FLA Rated
R t d Load
L d H tii
Heating C li
Cooling
M
Max Mi
Min CB H i
Heating H i
Heating H i
Heating C li
Cooling C li
Cooling C li
Cooling C bi d
Combined
Model Voltage (Full Load Amps 2°C Water Water
chilled water side. Full commercial construction with marine grade aluminium case. Amps) SST / 51°SCT
LWT °C size kW Power COP
Flowrate L/S
kW Power COP
Flowrate L/S
COP
Digital controls and upgradable to Rheem IQ® including BMS connectivity. HWC23 3 Ph/380-
10.7 8.3 61 20 17.3 4.7 3.7 0.7 12.6 4.7 2.7 0.6 6.4
415V/50Hz
HWC27 3 Ph/380-
13.2 10.3 61 20 21.1 5.4 3.9 0.8 15.7 5.4 2.9 0.8 6.8
415V/50Hz

DIMENSIONAL HWC37 3 Ph/380-


16.6 13.1 61 20 29.1 7.0 4.1 1.2 22.1 7.0 3.1 1.1 7.3
415V/50Hz
DRAWING OF
HWC49 3 Ph/380-
ACCENT MODEL 415V/50Hz
21.8 16.6 61 25 38.9 9.3 4.2 1.6 29.5 9.3 3.2 1.4 7.3
HWC340
HWC64 3 Ph/380-
31.2 25.2 61 40 50.1 12.6 4.0 2.0 37.5 12.6 3.0 1.8 7.0
415V/50Hz
HWC85 3 Ph/380-
37.9 28.2 61 50 66.6 16.6 4.0 2.6 50.0 16.6 3.0 2.4 7.0
415V/50Hz
HWC98 3 Ph/380-
43.6 33.1 61 50 77.8 18.7 4.2 3.1 59.1 18.7 3.2 2.8 7.3
415V/50Hz
HWC128 3 Ph/380-
62.4 50.4 61 80 100.2 25.2 4.0 4.0 75.0 25.2 3.0 3.6 7.0
415V/50Hz
HWC149 3 Ph/380-
65.4 49.7 61 80 116.6 28.0 4.2 4.7 88.6 28.0 3.2 4.2 7.3
415V/50Hz
HWC192 3 Ph/380-
93.6 75.7 61 100 150.3 37.8 4.0 6.0 112.5 37.8 3.0 5.4 7.0
415V/50Hz
HWC256 3 Ph/380-
124.8 100.9 61 150 200.4 50.4 4.0 8.0 150.1 50.4 3.0 7.2 7.0
415V/50Hz
HWC340 3 Ph/380-
151.6 112.6 61 160 266.3 66.2 4.0 10.4 200.1 66.2 3.0 9.6 7.0
415V/50Hz
Design conditions Hot side 39°C water inlet, 45°C water outlet and 51°C SCT, Cold side 12°C water inlet, 7°C water outlet and 2°C SST.

12 rheemthermal.com.au 13
HYDRONIC HEATING

A clean and silent approach to space heating Hydronic Heating (HW and HWW) Series
M ax
Max. Water
Hydronic heating provides a luxurious form of space heating for homes and commercial buildings, with heated water circulated FLA Ratedd LLoadd
R
Leaving Min Heating Airflow Weight Dimensions (mm)
MODEL Amps 10°C
either via underfloor loops or radiators. Hydronic heating creates constant temperature distribution and its radiant heating warms Electrical (Full Load Water Power COP Flowrate Length x Width x
CB size kW L/S (kg) Height
objects rather than air by natural convection, giving great heating efficiency and comfort. Amps) SST / 51°SCT L/S
temp. °C

Capability Air-to-Water Type


HW13.5-1 1 Ph/240V/50Hz 18.6 13.5 61 25 13.6 2.8 4.8 680 0.5 80 1000 x 475 x 1150
The Accent hydronic heat pump uses R407c and is available in both air-to-water and ground-sourced/water-to-water design. Air-to- HW23-1 1 Ph/240V/50Hz 27.3 20.7 61 32 23.4 5.1 4.6 1600 0.9 110 1150 x 565 x 980
water type is suitable for an operating range between 0°C to 40°C ambient. The use of water-to-water design (with the water source HW23-3 3 Ph/415V/50Hz 12.5 9.6 61 16 23.6 5.0 4.8 1600 0.9 110 1150 x 565 x 980
may be a dam, river or canal) or ground-coupled type (where the fluid is typically a water/glycol mix which is circulated in a closed
HW50-3 3 Ph/415V/50Hz 24.2 19.0 61 40 49.6 10.6 4.7 4700 2.0 240 1750 x 800 x 1015
ground loop) allows the use of heat pumps in cold climate zones where sub-zero ambient temperatures would otherwise preclude
this technology. For a water-sourced unit, the minimum entering water temperature to the heat pump’s secondary side would be Design conditions Hot side 39°C water inlet, 45°C water outlet @ 51°C SCT, 20°C Ambient, 60% RH @ 10°C SST
12°C, with the leaving water at 7°C. These parameters lower to 0°C/-5°C for water circulating in a closed ground-loop given that the
Ground-Sourced and Water-to-Water Type
risk of freezing is eliminated by the use of glycol. These units are capable of heating water up to 61°C but are also manufactured as
HWW23 3 Ph/415V/50Hz 10.7 8.4 61 20 27.0 5.0 5.0 - 0.9 100 900 * 700 * 625
reverse cycle to provide a potential for space heating and cooling.
HWW37 3 Ph/415V/50Hz 16.6 13.1 61 20 37.0 7.0 5.3 - 1.5 170 1400* 700 * 775
HWW49 3 Ph/415V/50Hz 21.8 16.6 61 25 49.6 9.4 5.3 - 1.9 230 1750 * 800 * 825
Efficiency
HWW64 3 Ph/415V/50Hz 31.2 25.3 61 40 64.0 12.7 5.0 - 2.5 300 1750 * 800 * 825

The efficiency of these units in hot water production is in the range of 2.5 to 5.0, with this figure varying depending on the Design conditions Hot side 39°C water inlet, 45°C water outlet and 51°C SCT, Cold side 20°C water inlet, 15°C water outlet and 10°C SST.
temperature requirements of the application as well as the temperature of the heat source.

Range

Our residential range focuses on home space heating with single phase options to a nominal heating capacity of 23kW and three
phase options to 50kW. The commercial range includes units up to 339kW. Technical data for a cross-section of the range is given
on the following page. Contact would be welcomed on other capacity and design configuration options.

Breadth of use
DIMENSIONAL DIMENSIONAL
The standard function of these units is to provide comfort space heating and cooling but the robustness and versatility of the Accent DRAWING OF DRAWING OF
design has seen use in a wide variety of applications, particularly in primary industries ACCENT MODEL ACCENT MODEL
HW23-3 HWW23
(such as piggeries and poultry sheds) and agriculture (greenhouse heating).

Extra Features

Heat exchangers can be stainless steel plate or copper shell-in-tube. Copper shell-
in-tube may be upgraded to cupro-nickel, either side, single-wall or with optional
vented design. Flow switch protection. Multiple safeties including low temperature
freeze protection on the chilled water side. Full commercial construction with marine
grade aluminium case. Digital controls and upgradable to Rheem IQ® including BMS
connectivity.

Gold
G ld C
Coastt A
Aquatic
ti CCentre
t - 2018 C
Commonwealth
lth G
Games V
Venue

14 rheemthermal.com.au 15
AQUACULTURE WATER HEATING
AND CHILLING

Industry-focused design and an unparalleled track record Chiller Models High Temperature
FLA Rated Load Min Cooling Airflow Water Water Weight Dimensions (mm)
Rheem has been at the forefront of providing purpose-designed plant for the heating and cooling of water for the aquaculture MODEL Electrical (Full Load Amps 10°C Power COP Flowrate connection Length x Width x
industry for two decades. The products vary from large Raypak gas boilers providing tank heating via secondary heat exchange to Amps) SST / 51°SCT CB size kW L/S L/S size mm (kg) Height
directly connected Accent high efficiency heat pumps, providing both water heating and cooling. CHW12-1 1 Ph/240V/50 Hz 19.4 12.6 25 11.7 2.7 4.3 1600 2.8 40 80 1150 x 565 x 980
CHW13.5-1 1 Ph/240V/50 Hz 21.9 15.5 32 13.6 3.1 4.3 1600 2.8 40 85 1150 x 565 x 980
Capability CHW21-3 3 Ph/415V/50 Hz 12.9 8.8 20 20.7 4.4 4.7 1835 2.8 40 145 1487 x 615 x 990
CHW43-3 3 Ph/415V/50 Hz 24.2 17.4 32 43.1 9.4 4.6 4500 2.8 40 240 1750 x 800 x 1015
Accent heat pump’s and chillers meet a diversity of aquaculture needs, with a capability to heat or chill tank and seawater from CHW55-3 3 Ph/415V/50 Hz 33.6 25.9 40 55.1 12.4 4.5 4700 2.8 40 260 1750 x 800 x 1215
6°C to 40°C. The range is available in both air-to-water and water-to-water design and for direct or indirect connection. Air-to-water
type is suitable for most locations, with an ambient temperature operating range between 0°C to 40°C. The use of water-to-water Design conditions 27°C leaving water temperature 27°C ambient temperature 45°C SCT and 10°C SST
design allows the use of heat pumps in cold climate zones where sub-zero ambient temperatures would otherwise be problematic.
The Accent units may be designed for heating only, reverse cycle heating and cooling or as chillers. The Raypak closed loop boiler Chiller Models Low Temperature
provides a robust gas option with high temperature hot water circulated for heating via a secondary heat exchanger.
FLA Rated Load Min Cooling Airflow Water Water Weight Dimensions (mm)
MODEL Electrical (Full Load Amps 10°C Power COP Flowrate connection Length x Width x
Efficiency Amps) SST / 51°SCT CB size kW L/S L/S size mm (kg) Height
CHW8.5-1 1 Ph/240V/50 Hz 19.4 13.0 25 8.6 2.8 3.1 1600 2.8 40 80 1150 x 565 x 980
With application temperatures typically maintained in the range of 24°C to 27°C, the Accent heat pump can work to COPs of up to CHW10-1 1 Ph/240V/50 Hz 21.7 15.2 32 10.2 3.1 3.3 1600 2.8 40 85 1150 x 565 x 980
6.0. COPs in heating are lower at colder ambients and are also lower when the plant is operated for water chilling. CHW15-3 3 Ph/415V/50 Hz 12.9 8.7 20 15.3 4.4 3.5 1835 2.8 40 145 1487 x 615 x 990
CHW32-3 3 Ph/415V/50 Hz 24.2 17.3 32 32.0 9.3 3.4 4500 2.8 40 240 1750 x 800 x 1015
Range CHW40-3 3 Ph/415V/50 Hz 33.6 25.8 40 40.7 12.2 3.3 4500 2.8 40 260 1750 x 800 x 1215

The Accent unit has broad application in aquaculture with capacity options ranging from plug-connected heat pump heaters at 9kW Design conditions 7°C leaving water temperature 27°C ambient temperature 45°C SCT and 2°C SST
output up to 339kW heating capacity for large-scale aqua farming projects. Technical data for a cross-section of the range is given
on the following page. Contact would be welcomed on other capacity and design configuration options.

Breadth of use

The versatility is enormous with uses made for aquaculture and aquascience ranging across fish species such as barramundi,
salmon, tuna and trout to shellfish such as abalone, lobsters and prawns, both in Australia and internationally. DIMENSIONAL DIMENSIONAL
DRAWING OF DRAWING OF
Extra Features ACCENT MODEL ACCENT MODEL
CHW10-1 CHW55-3

Full commercial construction with marine grade aluminium case and Rheem Cote® anti-corrosion treatment of the evaporator.
Titanium heat exchangers in direct connection units. Digital controls and upgradable to Rheem IQ® including BMS connectivity.

Huon Salmon, Tasmania - hatchery water chilling to 8°C

16 rheemthermal.com.au 17
RESIDENTIAL POOL AND SPA
GAS AND HEAT PUMP HEATING

65 years experience and Australia’s most trusted brands Residential Pool and Spa Heat Pumps
FLA Rated load Minimum
The Accent and Raypak brands are synonymous with the heating of Australian pools and spa and between them, represent over 65 Heating Power (Full amps @ circuit
Water
Design
Design Water
Weight
Dimensions (mm)
years market history. This experience is reflected in a broad product range, built to perform under all conditions, with unparalleled Model Electrical
Capacity input
COP
Load 10°C SST & breaker
Flow
TD
Pressure Connection
(kg)
Length x Width x
L/S drop Size (mm) Height
expertise in design and application which can be trusted to find the right solution for each individual project. Amps) 45°C SCT size
RA5356 1 Ph/240V/50Hz 23.0 3.6 6.4 29.0 21.8 40 2.5 2.2 48 50 137 876 x 876 x 978
Capability RA6356 1 Ph/240V/50Hz 28.0 4.9 5.8 36.2 26.8 40 2.5 2.7 48 50 141 876 x 876 x 1080
RA6358 3 Ph/415V/50Hz 28.0 4.9 5.8 13.1 10.1 20 2.5 2.7 62 50 141 876 x 876 x 1080
Rheem gas and heat pump product has the capability to heat the biggest or smallest of residential pools or spas, for season RA8358 3 Ph/415V/50Hz 32.0 5.6 5.7 15.1 12.0 20 2.5 3.1 62 50 162 876 x 876 x 1080
extension through to year-round constant heating. Our heat pumps are carefully matched to a pool’s heat load to ensure constant RTHP010-1 1 Ph/240V/50Hz 9.2 1.8 5.2 9.6 8.4 16 1.5 1.4 40 40 70 1000 x 475 x 800
temperature maintenance whilst Raypak gas provides the capability for rapid heating – giving virtual on-demand heating of spas RTHP015-1 1 Ph/240V/50Hz 14.1 2.5 5.7 19.1 11.8 25 1.5 2.2 40 40 80 1085 x 530 x 1150
and same-day responsiveness for most pools. RTHP024-1 1 Ph/240V/50Hz 24.5 4.6 5.4 27.3 18.6 40 2.8 2.1 40 40 110 1150 x 565 x 980
RTHP026-1 1 Ph/240V/50Hz 25.5 4.6 5.6 27.3 18.6 40 2.8 2.2 40 40 145 1487 x 615 X 990
Efficiency RTHP024-3 3 Ph/415V/50Hz 24.9 4.4 5.7 11.9 8.9 20 2.8 2.1 40 40 110 1150 x 565 x 980
RTHP026-3 3 Ph/415V/50Hz 25.8 4.4 5.9 11.9 8.8 20 2.8 2.2 40 40 145 1487 x 615 X 990
Whilst the market is full of grey noise in relation to efficiency, Rheem stands clearly as the true and verifiable benchmark. The Rheem Selecting the right
RTHP030-3 3 Ph/415V/50Hz 28.2 size
5.0 gas
5.6 heater
15.6 for
10.8 your
20 pool2.8or spa
2.4 heating
40 requirements
40 155 1487 x 615 X 990
RA Series carries AHRI Certification of compliance to the Florida Minimum Energy Performance Standard requiring a minimum COP
of 4.0 at 10°C ambient. Although this is an American Standard, Accent has voluntarily adopted this same design requirement for its
Premium Range. The outstanding heat capture of these units when the outside air is cold translates to market-leading COPs of up Residential Pool and Spa Gas Heaters
to 6.5 as the air warms to 27°C, reducing energy use and saving heating costs. Raypak’s atmospheric type gas heaters operate at
Nominal Rating Approximate Dimensions Connections
82% efficiency, equal to any heater in its category. Indoor Installations
Natural Gas Propane Gas All Models Gas Water
Model Flue
Range Input Output Input Output Height Width Depth Weight
mm mm Diameter
Height Overall
MJ/h kW MJ/h kW mm mm mm kgs mm
mm
The Rheem heat pump is available from plug-connected units at 7-10kW heating output to hard-wired single and three options up 131 Spartan 120 24 117 24 860 440 650 35 20 40 NA NA
to 28kW. The standard design is air-to-water type but water-to-water type is also available. The Raypak gas range begins with the
200 Residential 196 44 185 41 1085 530 650 70 20 50 175 1550
Spartan 131 spa heater and extends to the highly powerful Residential Model PO430, giving an unrivalled 94kW heating capacity.
Technical data for a cross-section of the range is given on the following page. Contact would be welcomed on other capacity and 280 Residential 278 62 261 58 1085 640 650 75 20 50 200 1550
design configuration options. 350 Residential 343 76 323 72 1085 730 650 85 20 50 225 1605
430 Residential 420 94 369 88 1085 870 650 90 20 50 250 1605
Extra Features

The Rheem Premium heat pump includes a full commercial construction with marine grade aluminium case, Rheem Cote® anti-corrosion Temperature Rise per Hour (Spa)
treatment of the evaporator, titanium heat exchangers, digital controls and upgradable to Rheem IQ® including BMS connectivity. The Spa Volume (Litres) DIMENSIONAL
Model
imported Rheem Classic Series is built tough with Rheem’s exclusive DuraSteel cabinet, power defrost and full onboard diagnostics. DRAWING OF
2000 3000 4000 5000
Raypak gas offers the reliability of atmospheric burner design and the robustness of powder coated all metal construction. ACCENT MODEL
131 Spartan 10º 6º 5º 4º RTHP015-1
200 Residential 17º 12º 9º 7º
280 Residential 25º 17º 12º 10º
350 Residential 32º 21º 16º 12º
430 Residential 38º 26º 19º 15º

Temperature Rise over 24 hours (Pool)


Model Pool Surface Area (m2)
20 40 60 80 100
131 Spartan
200 Residential 21º 15º 10º 8º 6º
280 Residential 26º 20º 14º 10º 8º
350 Residential 32º 25º 18º 13º 10º
430 Residential 34º 27º 20º 15º 12º

Note: Temperature rise is provided as a guide only and is based on outdoor


installations and an average wind speed of 2.2km/h and depth of 1.3m.
Temperature rise will be greater with indoor installations or lower with
higher wind speeds.

18 rheemthermal.com.au 19
COMMERCIAL AND AQUATIC
CENTRE POOL HEATING

Trust, Experience and Commitment Commercial and Aquatic Centre Heat Pumps
Nominal Nominal Working Water
Rheem is the premier name in the heating of commercial pools in Australia and Asia. Our reputation is built on a trust developed with Nominal No: of Min. CB Water Flow No: of Weight Dimensions (mm) Length x
Model Heating
power input Comp
Amps per
Size (l/s)
Press. Drop
Fans
Connection
(kg) Width x Height
specifiers, installers and users over a combined 65 years history in the Australian market with our Raypak gas heater and the Accent Capacity Phase (kPa) Size (mm)
pool heat pump. The products are now truly international with an installation spread from the United Arab Emirates, South Africa and RTHP040-3 39 6.7 1 14 25 2.8 40 2 40 170 1750 x 800 x 825
India through to most countries of South East Asia with the prestige of having provided heating and cooling for major international RTHP051-3 51 9.4 1 17 40 2.8 40 2 40 230 1750 x 800 x 1015
competitions such as the Commonwealth Games, Pan Pacs, Asian Games and most recently, the Pacific Games. The confidence RTHP065-3 66 12.4 1 26 40 2.8 40 2 40 300 1750 x 800 x 1215
in the Rheem name, the expertise and experience of our people and our commitment to locally based research and development HWP80-3 95 17.4 2 38 63 5.6 90 4 40 650 1735 x 1600 x 825
creates an unbeatable mix. HWP100-3 118 22.2 2 45 63 5.6 90 4 80 800 2200 x 1610 x 2020
HWP120-3 142 26.2 2 60 80 5.6 80 4 80 850 2200 x 1610 x 2270
Capability
HWP150-3 177 32.8 3 68 80 8.4 90 6 80 1200 3462 x 1962 x 2040
HWP180-3 213 39.3 3 87 100 8.4 90 6 80 1350 3462 x 1962 x 2290
Rheem gas and heat pump product has the capability and flexibility to meet the needs of any project, whether they be major aquatic
HWP200-3 235 43.5 4 90 100 11.2 90 8 80 1500 3462 x 1962 x 2040
centres or resort pools. Raypak gas provides heating, either by direct connection to the pool water or by the provision of a closed
HWP250-3 280 52.2 4 110 120 11.2 90 8 80 1700 3462 x 1962 x 2290
loop design, heating indirectly via a secondary heat exchanger. Accent heat pumps have the versatility to provide heating, heating
HWP300-3 354 64.8 4 148 160 11.2 90 8 80 2000 3462 x 1962 x 2290
and cooling or chilling only.
N t Heat
Note: H t pump input
i t and
d output
t t varies
i with
ith ambient
bi t (air-on)
( i ) conditions.
diti The
Th Nominal
N i l Heating
H ti C Capacity
it shown
h above
b iis th
the nominal
i l summer performance,
f being
b i att an air-
i
Efficiency on temperature of 27°CDB, 18°CWB (ambient air temperature), at 50% RH, with an entering water temperature of 27°C.

Rheem’s Accent Commercial Heat Pump stands at the forefront of product design and reflects an ongoing commitment to true and
verifiable high efficiency performance. COPs measured at full load are in the range of 5.4 to 5.9 with ratings at the common market
standard of 27°C ambient, but most importantly Accent’s design focuses on maintaining efficiency at colder air-on temperatures
and is evident in the large total evaporator area which characterizes the Accent design. Raypak’s atmospheric type gas heaters Residential Pool and Spa Gas Heaters
operate at 82% efficiency, equal to any heater in its category.
Nominal Rating Approximate Dimensions Connections
Indoor Installations
Natural Gas Propane Gas All Models Gas Water
Range Model Flue Height
Input Output Input Output Height Width Depth Weight
mm mm Diameter Overall
MJ/h kW MJ/h kW mm mm mm kgs
Our heat pumps are available in multiple capacity steps up to a maximum 354kW heating in both air-to-water and water-to-water mm mm
type. Raypak gas is available from 539MJ to a massive 4224MJ input, equivalent to 960kW heating as a single unit for direct or 127 Premium 110 25 103 23 895 580 280 42 20 40 125 1100
indirect connection. Technical data for a cross-section of the range is given on the following page. Contact would be welcomed on 167 Premium 163 36 154 34 905 390 610 67 20 40 150 1470
other capacity and design configuration options.
280 Premium 278 62 261 58 1085 640 650 75 20 50 200 1550
Extra Features 430 Premium 420 94 369 88 1085 870 650 90 20 50 250 1605

Full commercial heat pump construction with marine grade aluminium case, Rheem Cote® anti-corrosion treatment of the
evaporator, titanium heat exchangers, Rheem IQ® control including BMS connectivity. Raypak Commercial Gas B-Type design Temperature Rise per Hour (Spa) Temperature Rise over 24 hours (Pool)
includes a cupronickel heat exchanger, bronze headers, exclusive stainless steel burner design and flow sensing protection to water Model Spa Volume (Litres) Pool Surface Area (m2)
flow. Both ranges are characterised by ready access to parts, technical support and easy serviceability. 2000 3000 4000 5000 20 40 60 80 100
127 Premium 10º 6º 5º 4º
167 Premium 14º 9º 7º 6º
280 Premium 25º 17º 12º 10º 26º 20º 14º 10º 8º
430 Premium 38º 26º 19º 15º 34º 27º 20º 15º 12º

Note: Temperature rise is provided as a guide only and is based on outdoor installations and an average wind speed of
2.2km/h and depth of 1.3m. Temperature rise will be greater with indoor installations or lower with higher wind speeds.

Taurama A
T Aquatic
ti CCentre,
t Papua
P New
N Guinea
G i

20 rheemthermal.com.au 21
ELITE SPORTS

The choice of champions Elite Sports - Reverse Cycle Heat/Cool


TTotal
t l heat
h t RLA (R
((Rated
Rated
t d T t l
Total Di
Dimen sions
i
Dimensions ( )
(mm)
Rheem is the most trusted source of water heating and chilling for Australia’s elite athletes and high-level commercial sports with its Model rejection Power COP
FLA (F
(Fullll
Load
Fl
Flowrate Mi
Min CB
Cooling Power COP
RLA (R
(Ratedd Fl
Flowrate W i h
Weight
Length x Width x
technologies involved in hot and cold recovery pools and baths for virtually every landmark training venue or sporting arena. Our Load Amps) (L/S) size Load Amps) (L/S) (kg)
kW Amps) kW Height
installation list covers a who’s who of Australian sport and covers iconic stadiums such as the Sydney Cricket Ground, Ballymore RTCH25-3HC 24.3 4.3 5.7 12.5 8.7 2.8 20 14.7 3.8 3.9 8.0 2.8 100 1150 x 565 x 980
Stadium, Blundstone Arena and the redeveloped Adelaide Oval to Olympic-focused facilities such as the Australian Institute of RTCH38-3HC 38.3 6.7 5.7 19.0 14.4 2.8 20 25.2 6.0 4.17 13.7 2.8 170 1750 x 800 x 825
Sport. RTHC51-3HC 51.3 9.4 5.5 24.2 17.4 2.8 40 33.7 8.4 4 16.2 2.8 230 1750 x 800 x 1015
RTHC66-3HC 66.3 12.4 5.4 33.6 25.9 2.8 40 43.0 11.1 3.89 24.6 2.8 300 1750 x 800 x 1215
Capability
Design conditions: Ambient 27°C DB 60% RH, Heating 27°C EWT 10°C SST & 45°C SCT, Cooling 10°C EWT 2°C SST & 40°C SCT
Power supply 380 -415V / 50 Hz / 3 phase
Accent technology provides a capability to heat or chill from 6°C to 40°C. The range is available in both air-to-water and water-
to-water design and for direct or indirect connection. Air-to-water type is suitable for most locations, with an ambient temperature
operating range between 0°C to 40°C. The use of water-to-water design covers all operating conditions and allows the simultaneous
heating of a hot pool as a by-product of the chilling of the cold pool, all from a single unit. The Accent unit may be designed for
heating only, reverse cycle heating and cooling or as chilling only. The Raypak gas heater provides a robust high capacity option for
rapid temperature boosting or hot pool heating.

Efficiency

Benchmark efficiency levels are maintained by the specialist design of the units supplied for elite sport heating and cooling, with the
units featuring increased heat exchanger capacity, enlarged evaporators and specialist control.

Range

While the formal range of heat pumps and chillers extends to 60kW heating and 50kW chilling, Rheem has the capability to custom-
design and build larger systems. Likewise, while our Raypak gas plant used in the elite sports heating would typically be in the range
of 62kW to 94kW, higher capacity options are also available. Technical data for a cross-section of the range is given on the following
page. Contact would be welcomed on other capacity and design configuration options.
North Adelaide Football Club High Performance Centre plunge pools

Breadth of use 1400


DIMENSIONAL DIMENSIONAL
Rheem chillers and heater options for ice baths and hot recovery pools are not limited to elite sports and their use extends to resorts, DRAWING OF DRAWING OF
health clubs and homes. ACCENT MODEL ACCENT MODEL
RTCH25-3HC 700 HWW20
Extra Features

Full commercial construction with marine grade aluminium case and Rheem Cote® anti-corrosion treatment of the evaporator. 32mm COPPER

Titanium heat exchangers. Digital controls and upgradable to Rheem IQ® including BMS connectivity. Possible inclusion of remote WATER PIPES

condenser to plunge-pool design. Possible manufacture in split design where ventilation is an issue. Gas plant available as direct or TOP VIEW

indirect connection.

700

ACCESS ACCESS ACCESS


PANEL PANEL PANEL
WATER IN

WATER IN

WATER OUT
WATER OUT

65 190 190 65
FRONT VIEW END VIEW

1400 700

680 655

25

Greater
G t W Western
t Sydney
S d Giants
Gi t AFL High
Hi h Performance
P f C
Centre
t plunge
l pools
l BACK VIEW END VIEW

22 rheemthermal.com.au 23
DEHUMIDIFIERS

Controlling relative humidity in pool halls DH Series Dehumidifiers


Moisture Max
Controlling relative humidity in a pool hall is critical for the comfort of bathers but just as importantly, it is critical for the health FLA RLA
Min Removal
Approx Total Sensible
Space Dimensions (mm)
of the space as a workplace or place of fun and enjoyment but also for the integrity of the building. Accent’s dual heritage in air (Full (Run Outlet Heat Cooling Supply Air Weight
Model Electrical
Load Load
CB Power @24°C
Temp Rejection Capacity
Heat
L/S (kg)
Length x Width x
conditioning and pool heating means that it has a unique skill set to provide energy-efficient solutions into the aquatic sector for size 60% RH Capacity Height
Amps) Amps) °C kW kW
litres/hr kW
space condition control via refrigerant dehumidification.
DH300 1 Ph/415V/50Hz 23.7 16.5 32 3.0 7 33 12 4.5 7.5 500 150 1050 x 1050 x 615
Capability DH500 3 Ph/415V/50Hz 16.6 13.6 20 6.0 12 33 20 7.5 12.5 900 200 1600 x 1250 x 725
DH800 3 Ph/415V/50Hz 27.4 22.7 32 10.0 18 33 28 12.5 15 1500 300 1600 x 1405 x 1055
Accent’s DH Series Dehumidifiers are typically designed to maintain the relative humidity inside pool halls at the ideal band of 50-
DH1200 3 Ph/415V/50Hz 26.8 21 32 9.7 27 33 47 18.5 25 2250 450 1855 x 1605 x 1200
65%. The units are for indoor installation with recirculation of the return air from the pool hall at a temperature range of 20°C to 35°C.
The moisture removal capability of the range extends from 7 litres/hour to 39 litres/hour at 24°C/60% RH.
DEHUMIDIFIER WITH REMOTE CONDENSER
Efficiency
AND POOL CONDENSER
Dehumidification control of a pool hall provides substantial energy efficiency, in contrast to the alternative method of make-up and
exhaust. Up to 80% of the energy value held in the warm moist air of the pool hall is recovered and used by the DH unit either for
space heating or as a secondary source of pool water heating.

Range

The range extends from 3HP to 12HP options. Technical data for a cross-section of the range is given on the following page. Contact
would be welcomed on other capacity and design configuration options.

Breadth of use

While the design of our plant is modular to allow larger-scale project use, Rheem dehumidification is best suited to smaller pool
centres such as swim schools and hotel and resort facilities. Residential use is also common. Code requirements vary by area and
can impact on application.

Extra Features
DIMENSIONAL
DRAWING OF
Full commercial construction with marine grade aluminium case and Rheem Cote® anti-corrosion treatment of the coils. Digital ACCENT MODEL
controls. Optional upgrade to remote evaporator to allow heat rejection to outdoors and the provision of a cooling function. Optional DH800
pool condenser allows heat recovery to pool water heating.

DIMENSIONAL
DRAWING OF
ACCENT MODEL
DH800-RC

Ian Thorpe Aquatic Centre


Centre, Sydney

24 rheemthermal.com.au 25
®
RHEEM IQ CASE STUDY 1

Rheem’s new tariff optimising intelligent control


Rheem Thermal has a clear and ongoing commitment to locally based research and development. A key motivator in this work is
the achievement of ever improving efficiency thresholds in the energy use of our products. But while improved energy efficiency
has clear environmental benefits for the planet, it is also critical that efficiency gains translate to reductions in electricity billing.
Rheem IQ® bridges this gap and provides a tariff intelligence to the running of Rheem heat pumps so to provide least cost heating.

Electricity pricing is increasingly structured on a time-of-use and/or demand basis. This means that the electricity price per kWh
changes potentially by time-of-day and day of the week. The variance in operating cost of electrical equipment between peak and
off peak times can be up to four times.

Rheem IQ® creates programming logic to optimise off peak and shoulder pricing operation by slight movements of the target
water temperature.

The most directly applicable use of Rheem IQ® is in pool heating, where cheaply produced off peak heat contribution is effec-
tively stored in the pool. Differing temperature parameters are available in each tariff period with the intention of peak operation is
postponed or avoided to the maximum extent feasible, consistent with the desire for the temperature of the pool at different times
of the day and weekend.

HEAT PUMP POOL HEATING COSTS BY HOUR*

Best time to save

Moderate savings
SYDNEY OPERA HOUSE
Peak price

Creating a sustainable future proposition, in that it bears a constant but assists with the task of chilling, or
*Costs shown are indicative only. These represent the heating cost per for an architectural icon cooling load due to the lighting and dispersing heat out of the building. When
hour of a Rheem Pool Heat Pump Model RTHP015-1 at nominal condi-
tions. Electricity prices applied are as Published Rates for Origin Energy people loads. The building draws water you combine the efficiencies in hot water
for NSW Domestic TOU Powersmart effective 8/1/16. The comparative When it comes to challenging retrofits,
heating cost for Domestic connection would be approx $0.56/hour. Elec- from Sydney Harbour through large and chilling, the Accent unit is operating
Weekends & Public Holidays Week Days
tricity pricing varies by State and contact with local retailers should be
made to validate rates applicable to any particular case.
few can match the task of helping the capacity heat exchangers and uses it to at a COP of above 7.0, making the system
Sydney Opera House win a prestigious transfer heat (generated by chillers, which a crucial component of the energy ef-
4 Star Green Star rating from the Green keep the internal spaces at the desired ficiency improvements which led to the 4
Building Council of Australia. temperature) to the harbour. So the key Star Green Star performance rating.
The time clock graphics clearly show the basis on which the Rheem tariff intelligence is question became: how could the heat
able to achieve substantial reductions in heating costs and save money. Completed in 1973, Australia’s most generated by the chillers also be used The project was unique and required con-
iconic structure required a series of to improve energy efficiency and make a siderable direct involvement by Rheem in
Achieving a balance of off peak and shoulder electricity use will see pool heating costs energy efficiency improvements in order powerful case for green credentials? the application design. The expertise Ac-
almost halved compared with connection to the standard flat rate. to see it become one of the few World cent has in water heat pump design, and
Heritage buildings to be awarded green A unique dual benefit solution particularly around water-to-water-type
Saving Pump Costs certification. Two key areas to be ad- Rheem commissioned the installation of heat pumps, proved to be invaluable.
dressed was the generation of internal hot two Accent water-to-water hot water heat
The potential for saving in heating costs is extended to the recirculating pump. Rheem IQ ® water and the ability to remove heat from pumps deep within the Opera House Features
has the potential to control power to the water pump, so that the savings extend to the total the building. structure in July 2015. Both units were
heating system. The pump will operate only for those hours needed for heating and in line designed to extract heat from the air con- • Opera House has reduced energy use
with the run profile determined by the intelligent controller to minimise heating costs. Rheem was asked to take part in the ditioning condenser water loop at high by more than 10% over the past 5 years.
ambitious project in late 2014, due to efficiency for use in heating the building’s • 2 Accent Models HWW50
Advanced Operational Control and User Interrogation Features its extensive array of hot water system hot water storage capacity.
expertise. Not surprisingly, the task wasn’t
The tariff intelligence of the controller is only one of the new features offered, with the functionality extending to outdoor fan control, a simple one. In carrying out that task, the condenser
circulating pump control, de-ice management, alarm logging and PCo connectivity. For example, the BMS interface capability of water is cooled, so the heat pump not
the unit will allow direct interrogation, status checking and performance data review. The Opera House represents a unique only provides high efficiency hot water

26 rheemthermal.com.au 27
CASE STUDY 2 CASE STUDY 3

TAURAMA AQUATIC CENTRE, PORT HOLIDAY INN RESORT BARUNA BALI


MORESBY, PAPUA NEW GUINEA

As host nation of the 2015 Pacific Games, international competition. Features The Holiday Inn Resort Baruna Bali is phase hotel owners expressed their per day and save in excess of 80% of the
the Papua New Guinea Government built in a traditional low-rise Balinese desire to incorporate the latest high ef- energy used by a traditional hot water
commissioned the construction of the Rheem’s strong heritage with major inter- • 3 Accent Models HWP250 style, complementing its beachfront ficiency water heating systems into the system.
Taurama Aquatic Centre and Indoor national competition pools which com- • Reverse cycle design setting. In 2008 the resort underwent a hydraulic design. This resulted in the
Sports Complex as a sporting facility to menced with the heating and cooling of • 500KW cooling load major renovation and refurbishment and installation of the first and largest hot The Accent heat pumps were an ideal
international competition standards for the Bangkok Aquatic Centre in Thailand opened for business in March 2009. All water hybrid solar/ heat pump system in choice for boosting in this climate. COP’s
• 300kW heating load
swimming, volleyball, basketball and a for the 1998 Asian Games was clearly major mechanical, hydraulic and electri- Indonesia. of 4-5 are experienced. Traditionally when
variety of other indoor sports. recognised with the project consultants • 3,500,000 litres of water cal services were replaced and upgraded solar pre-heat systems are installed
directly specifying three Accent pool heat • Site Commissioning by Accent with the latest high efficiency systems The system design features solar pre- electric or gas boost heaters are used to
Accent was involved from early stages pump models HWP250 to meet the esti- available heat, consisting of Rheem solar col- boost in times of less solar gain. Boost-
in the design of a heat pump system mated total pool cooling load of 500kW lectors and storage feeding into a heat ing with a heat pump reduces the energy
with reverse cycle capability to provide and heating load of 300kW. This system Features pump and storage boost system. In the a traditional electric or gas heater would
both heating and cooling of the centre’s was commissioned by Accent in May event solar gain is reduced by inclement use to boost the water by 75-80% mak-
Olympic standard 50m competition pool 2015 and the pools were successfully • 192 Rheem solar collectors weather the heat pump system auto- ing this the most energy efficient system
and separate 25m warm up pool, which held at 27°C during the competition. • 11 Accent hot water heat pumps matically boosts the water ensuring an available.
together have a combined water volume • 63 Rheem storage tanks uninterrupted hot water supply to guests
of 3,500,000 litres. and facilities within the resort. The system was supplied and installed
• 5 separate hot water zones
by PT Dewata Vulcanindo of Indonesia.
With an average daily temperature in Port • Design capacity 60,000L per day Some 192 Rheem solar collectors, 11
Moresby for July of 29.2°C, the critical • Savings in excessive 80% Accent hot water heat pumps and
challenge for these outdoor pools was 63 Rheem storage tanks were installed
to ensure the achievement of a water The resort has some 195 rooms with a servicing 5 separate hot water zones. The
temperature of between 25 to 28°C (77 to number of kitchens, bars, laundry, gym system was designed to Intercontinental
82°F) in line with the rules set by FINA for and day spa facilities. During the design design parameters to deliver 60,000L

28 rheemthermal.com.au 29
CASE STUDY 4 CASE STUDY 5

GOLD COAST AQUATIC CENTRE NORTH SYDNEY OLYMPIC POOL

Rheem was contacted by commercial “A key requirement was to achieve lower The heat pumps also include Building North Sydney Olympic Pool is a well and strainers on the inlet side of the units Swimplex of Sydney, Australia.
pool specialists, Trisley Hydraulic Servic- energy and running costs,” says Paul Maintenance Control (BMS) capabilities. known Sydney landmark, being situated to prevent fouling. Heat is extracted from
es, with a clear brief: a new pool heating Stevenson from Stevenson + Associates. This enables the operators to control and under the Sydney Harbour Bridge with the sea water and returned back to the Accent pioneered this type of technology
system was needed to heat almost nine “And a secondary requirement was for interrogate the units in relation to a broad the adjoining Luna Park. In 1999 in a harbour. in Australia and remains at the forefront of
million litres of water at the Gold Coast an ecologically sustainable development range of operating parameters, including major environmental initiative, the heating product innovation taking its experience
Aquatic Centre. (ESD) and lower emissions. checking operation, data logging of heat system for the pool was upgraded from Significant energy savings have been and expertise to the world. Other projects
pump performance, monitoring tempera- gas boiler to high efficiency electric heat achieved with the additional capital of note include the Australian Institute of
The new system was part of a major, The heat pumps included upgrades to tures etc. pump. required to install the heat pumps being sport Alpine Training Centre in Thredbo
$41 million upgrade of the centre, which cope with the highly exposed coastal po- recovered through energy cost savings NSW. In this project ground tempera-
was needed to bring the facilities up to sition and included full marine-grade alu- A revolutionary feature is the hot and cold North Sydney Council had a goal to install in the first 3-4 years. ture is used as the heat source. Ground
international competition standards for minium construction and the unit’s evapo- recovery pool system design, which is a system that was energy efficient and temperature remains relatively stable
2014 Pan Pacific Masters Games and, ul- rators are treated with Rheem Cote®. one of the showpiece components of the innovative, The NSW Sustainable Energy Accent custom-manufactured water throughout the year and provides an ideal
timately, the Gold Coast Commonwealth Rheem’s engineering ability and flexibility project. The Rheem water-to-water heat Development Authority also played a key to water heat pumps for this project with heat source in cold climates. air-to-water
Games being held in April 2018. in manufacture to customise its product pump simultaneously heats the hot pool role in sponsoring the transfer to high ef- a nominal capacity up to 375kW each with heat pumps are not suitable in such cli-
to site-specific needs is shown in the from the energy recovered from chilling of ficiency technology. a total installed capacity of 1100kW. water- mates due to heat pump capacity de-rate
The centre includes an existing 50m, 25m response to the specific visual and noise the cold pool. to-water heat pumps were the ideal choice that occurs during severe winter ambient
and diving pools, in addition to the new requirements of the project. The cases of While heat pumps in Australia are typi- for the site due to limitations on avail- temperatures.
50m competition pool, indoor learn-to- the heat pumps were powder coated in a Features: cally of air-to-water design, the project able space. Equivalent air-to-water heat
swim pool and a splash pool. The work champagne colour to allow them to blend team saw the potential for a water-to- pumps would have taken up more than
also included the heating and chilling of in with the enclosure designs. Low noise • 1900kW total heat pump capacity water hot water heat pump system. The 10 times the space required for water-to-
hot and cold athlete recovery pools. fans were used and the structural frames • Air-to-water and water-to-water plant relatively constant temperature of the water heat pumps. This high efficiency
In line with the specification released by of the units were modified to allow the • 9,000,000 litres of water harbour provides a perfect heat source heat pump system continues to operate
aquatics consultants, Stevenson & Associ- integration of large acoustic louvers, so for water-to-water heat pumps. Harbour today providing ongoing significant energy
ates, Rheem provided eight Accent Air heat to achieve targets in relation to reduced • Specialist upgrades for visual, noise, water is pumped through the heat pump savings to North Sydney Council. The
pumps with a total capacity of 1900KW. noise at pool deck. controls and corrosion-resistance heat exchangers, with sacrificial anodes system was supplied and installed by

30 rheemthermal.com.au 31
CASE STUDY 6 CASE STUDY 7 CASE STUDY 8

HUON AQUACULTURE ROYAL HOBART UNIVERSITY OF WOLLONGONG


HOSPITAL iC INNOVATION CAMPUS

The Huon Aquaculture Group in Tasma- fish live in optimum conditions and will Features: Accent’s involvement in the major Engineering Services Up- The Innovation Campus (iC) is a world-class, award-winning
nia is globally recognised as being the go to sea healthy and in peak condition. • Two Accent Models CHW50 grades of the Royal Hobart Hospital (RHH) beginning in 1999 research and commercial precinct developed by the University
premium producer of fresh and smoked The small amount of water exchanged in • Chilling ability to 8°C was one its early success stories. A Performance Contract of Wollongong (UOW) – one of Australia’s leading research and
salmon products. For this business, the hatchery each day gets used in other was entered into between the Honeywell organisation and the teaching universities.
• Specialist fan speed and head pressure
there’s no more vital task than providing areas of the farm through composting, Government of Tasmania. Systems and services upgraded as
control
the constant water heating or chilling land spreading and irrigation. part of the project included the installation of Accent hot water iC is a centre of Australian innovation and research excellence,
required for optimum fish stock growth. • Upgraded heat exchanger capacity heat pumps to replace redundant electrode boilers and site- as home to a number of UOW’s leading research institutes
The project brief required the chill- wide heating water reticulation. working to develop solutions to some of the great scientific,
For a recent application at one of its ing plant to be able to vary the water engineering and social issues of the 21st century.
key hatcheries, the company turned to temperatures in the tanks from 7 to 14°C The upgrades were completed in August 1999 with the energy
Rheem for a specialist, large capacity month-by-month depending on where guarantee period commencing in late July. The guarantee was Rheem’s involvement is hot water supply to a three level com-
chiller. The task encompassed a total the fish were in their growth cycle. then for a reduction in energy costs of some $300,000 per mercial office building within the campus, with multiple small
volume of 330,000 litres and 260 square annum. fan coil units used for heating and cooling. Water is supplied at
metres of exposed water area to support Rheem commissioned the installation 55°C.
9,000 kg of fish. All this is maintained of two Accent 50kW chillers in early The heat pumps were installed in groups of up to four units
within 12 x 22,000-litre tanks (housed 2015. The plant includes titanium heat across four buildings of the campus. The units were linked to Features:
within an insulated room). The system exchangers so there is no risk any leach- hot water storage of up to 10,000 litre tanks for provision of a • Accent HW250
also includes a 40,000-litre bio filter. ing of chemicals into the water from the tank temperature up to 65°C. Detailed monitoring of hot water
Huon Aquaculture is committed to materials at the contact point. • BMS connectivity
usage was undertaken, with a maximum hourly use of some
rigorous environmental standards. The 3,400 litres being shown for GEHA building and with continu- • Compressor staging
facility uses a full recirculation system, ously strong hot water demand of an average 2,000 litres/hour
which means it reuses 95-99 per cent over the 10 hour period from 9AM to 7PM.
of the water needed, which ensures the
Features:
• 13 Accent hot water heat pump Models HW42

32 rheemthermal.com.au 33
CASE CASE CASE
CASE STUDY 9 STUDY 10 STUDY 11 STUDY 12

CABLE BEACH CLUB RESORT & SPA ADELAIDE OVAL FLEURIEU REGIONAL HARBOURVIEW
REDEVELOPMENT AQUATIC CENTRE HOTEL – MACAU

The award winning Cable Beach Club investigate options. Economic evalua- for the laundry equal to the estimated The redevelopment of the iconic Adelaide The Fleurieu Regional Aquatic Centre will The Harbourview Macau boasts an exqui-
Resort & Spa at Broome in Western Aus- tion clearly favoured the use of a reverse cost of heat pump operation for pool Oval has been one of Australia’s most provide the Fleurieu Peninsula communi- site architectural style reminiscent of 18th
tralia welcomed its first guests in 1988 cycle air-to-water heat pump. Likewise, heating and cooling. lauded projects in delivering a modern ties with a modern sport and recreation century Prague. This meant the specif-
and began a twenty year history with the heat pump approach provided the spectacular stadium that is at forefront of facility when opened in March 2017. The ics of the pool and hot water heating
Rheem in 1996 with the installation of a unique benefit of the dual capacity for The heat pump system was installed and structural and building services engineer- centre has already received national solutions for its 389 guest rooms and 55
unique pool heating and cooling system. heating or cooling. commissioned by Accent prior to Easter ing, whilst retaining the sense of history. recognition for community partnership and suites was a critical aspect of the overall
1997. Guest reaction to the “Cool Pool” collaboration. design.
While Broome’s climate is glorious for the The installation of the two Accent models was immediate and greatly increased The project includes five Accent chiller
majority of the year, management faced HWP50 also provided the opportunity to utilisation and much direct positive feed- models CH20-3 providing chilled water The centre includes a 25M, program and In response to the design requirements,
an unusual problem with its outdoor tackle the ongoing operating cost of the back to Cable Beach management. for ice baths used for player and athlete warm water pools and includes an innova- Rheem commissioned the installation of
Ocean Pool. resort laundry. Refrigerant gas desuper- recovery sessions. Physical restrictions tive mix of technology with a clear focus on three 300-kilowatt hot water heat pumps
heaters were added to each compressor Features: in terms of the placement of plant meant sustainability and energy efficiency. Pool and two 60-kilowatt heat pumps for the
The pool is free form with a total area of the two heat pumps. these units were custom designed and heating is provided by direct connection indoor swimming pool.
of around 405m2 and water volume of • Two Accent pool heat pump Models built by Rheem as “splits”, with the remote Accent heat pumps. Space heating and
some 540m3. The pool was unheated The desuperheater captured the heat of HWP50 condensers installed up to 50m from the conditioning is provided by air handling
and in winter could fall as low as 17°C to the refrigeration circuit and transferred • Heat recovery to each compressor, plant room units. plant with water at 45°C provided by an
20°C. In contrast, during the hot summer this to the hot water storage tanks serving 800kW Accent’s mechanical hot water
• Two 3,000 litre hot water storage tanks,
period, the water temperature reached the laundry. heat pump system.
pumps and controls
35°C making it far too warm for comfort-
able swimming. The value of the heat reclaim (preheating
some 6,000 litres of water overnight to
The owner engaged Ove Arup Engi- between 60°C to 63°C), equated to a
neering Consultants from Sydney to reduction in gas heating costs

34 rheemthermal.com.au 35
INSTALLATION SCHEMATICS CLEARANCES

MINIMUM CLEARANCES REQUIRED


TYPICAL POOL INSTALLATION FOR POOL HEAT PUMPS

FIGURE: 1 - RTHP010 & RTHP015 FIGURE: 2 - RTHP026

FIGURE: 3 - RTHP024 TO RTHP040 FIGURE: 4 - RTHP051 & RTHP065

FIGURE: 5 - 5356 TO 8358


TYPICAL HOT WATER INSTALLATION

NOTE:
HOT WATER FLOW
TO BUILDING 1) The above drawings represent standard units.
contact Rheem Thermal Systems Group if further
information is required on special built units.
HOT 2) When using multiple units allow 2000mm gap
WATER between the evaporator coils.
RETURN
FROM
BUILDING

HEAT PUMP

3Ø 415 V a.c. TANK THERMOSTAT STORAGE TANKS RECIRCULATION BOOST HEATER


SENSOR (GAS OR ELECTRIC)

COLD WATER
SUPPLY
HEAT PUMP

3Ø 415 V a.c. PRIMARY PUMP

36 rheemthermal.com.au 37


,ŝŐŚŵďŝĞŶƚ,ŽƚtĂƚĞƌŚĞĂƚƉƵŵƉƐƋƵŝĐŬƌĞĨĞƌĞŶĐĞŐƵŝĚĞ
ZϰϬϳĐŵŽĚĞůƐǁŝƚŚŚŽƚŐĂƐŝŶũĞĐƚŝŽŶĚĞͲŝĐĞ͘

DĂdž͘>ĞĂǀŝŶŐ ŽƉƉĞƌ
ZĂƚĞĚ>ŽĂĚ ZĞůĂƚŝǀĞ tĂƚĞƌ ŝŵĞŶƐŝŽŶƐ;ŵŵͿ
tĂƚĞƌ ŵďŝĞŶƚ DŝŶ ,ĞĂƚŝŶŐ EŽ͗ŽĨ ŝƌĨůŽǁ ǁĂƚĞƌ tĞŝŐŚƚ
DŽĚĞů sŽůƚĂŐĞ WŚĂƐĞ̴ ,Ğƌƚnj &>;&Ƶůů>ŽĂĚŵƉƐͿ ŵƉƐϭϮΣ ŚƵŵŝĚŝƚLJ WŽǁĞƌ KW &ůŽǁƌĂƚĞ >ĞŶŐƚŚdžtŝĚƚŚdž
ƚĞŵƉĞƌĂƚƵƌĞ Σ ƐŝnjĞ Ŭt ĨĂŶƐ >ͬ^ ĐŽŶŶĞĐƚŝŽŶ ;ŬŐͿ
^^dͬϱϭΣ^d й >ͬ^ ,ĞŝŐŚƚ
Σ ƐŝnjĞŵŵ
,tϮϱ,Ͳϯ,' ϯϴϬͲϰϭϱ ϯ ϱϬ ϭϭ͘ϵϯ ϵ͘ϲϰ ϲϭ ϯϬ ϲϬ ϮϬ Ϯϱ͘ϰϯ ϰ͘ϵϴ ϱ͘ϭϭ Ϯ ϭϲϬϬ ϭ͘Ϭ ϯϮ ϭϬϬ ϭϭϱϬdžϱϲϱdžϵϴϬ
,tϰϬ,Ͳϯ,' ϯϴϬͲϰϭϱ ϯ ϱϬ ϭϴ͘ϵϲ ϭϱ͘ϰϲ ϲϭ ϯϬ ϲϬ Ϯϱ ϯϵ͘ϯϱ ϳ͘ϱϵ ϱ͘ϭϴ Ϯ ϮϯϬϬ ϭ͘ϱϳ ϱϬ͘ϴ ϭϳϬ ϭϳϱϬdžϴϬϬdžϴϮϱ
,tϱϬ,Ͳϯ,' ϯϴϬͲϰϭϱ ϯ ϱϬ Ϯϰ͘Ϯ ϭϵ͘Ϭϭ ϲϭ ϯϬ ϲϬ ϰϬ ϱϮ͘ϲϰ ϭϬ͘ϱϴ ϰ͘ϵϴ Ϯ ϰϳϬϬ Ϯ͘ϭ ϱϬ͘ϴ ϮϵϬ ϭϴϬϬdžϴϬϬdžϭϮϮϬ
,tϲϱ,Ͳϯ,' ϯϴϬͲϰϭϱ ϯ ϱϬ ϯϯ͘ϲ Ϯϳ͘ϳϬ ϲϭ ϯϬ ϲϬ ϲϯ ϲϴ͘Ϭϭ ϭϯ͘ϵϯ ϰ͘ϴϴ Ϯ ϰϳϬϬ Ϯ͘ϳϭ ϱϬ͘ϴ ϯϬϬ ϭϴϬϬdžϴϬϬdžϭϮϮϬ
,tϴϬ,Ͳϯ,' ϯϴϬͲϰϭϱ ϯ ϱϬ ϯϱ͘ϲ Ϯϴ͘ϲ ϲϭ ϯϬ ϲϬ ϲϯ ϳϴ͘ϳ ϭϱ͘ϯ ϱ͘ϭϰ Ϯ ϰϳϬϬ ϯ͘ϭϯ ϲϱ ϰϬϬ ϭϳϱϬdžϭϭϳϱdžϭϮϭϱ
,tϭϬϱ,Ͳϯ,' ϯϴϬͲϰϭϱ ϯ ϱϬ ϰϳ ϯϲ͘ϲϮ ϲϭ ϯϬ ϲϬ ϲϯ ϭϬϱ͘Ϯϴ ϮϬ͘ϲϰ ϱ͘ϭϬ Ϯ ϳϯϯϱ ϰ͘ϭϵ ϲϱ ϲϬϬ ϮϮϭϬdžϭϭϳϱdžϭϯϬϬ
,tϭϯϱ,Ͳϯ,' ϯϴϬͲϰϭϱ ϯ ϱϬ ϲϱ͘ϴ ϱϰ͘Ϭ ϲϭ ϯϬ ϲϬ ϭϬϬ ϭϯϲ͘ϬϮ Ϯϳ͘ϯϰ ϰ͘ϵϴ Ϯ ϳϯϯϱ ϱ͘ϰϭ ϲϱ ϲϱϬ ϮϮϭϬdžϭϭϳϱdžϭϯϬϬ

ZϰϬϳĐŵŽĚĞůƐǁŝƚŚŽƵƚĚĞͲŝĐĞ͘

DĂdž͘>ĞĂǀŝŶŐ ŽƉƉĞƌ
ZĂƚĞĚ>ŽĂĚ ZĞůĂƚŝǀĞ tĂƚĞƌ ŝŵĞŶƐŝŽŶƐ;ŵŵͿ
tĂƚĞƌ ŵďŝĞŶƚ DŝŶ ,ĞĂƚŝŶŐ EŽ͗ŽĨ ŝƌĨůŽǁ ǁĂƚĞƌ tĞŝŐŚƚ
DŽĚĞů sŽůƚĂŐĞ WŚĂƐĞ̴ ,Ğƌƚnj &>;&Ƶůů>ŽĂĚŵƉƐͿ ŵƉƐϭϮΣ ŚƵŵŝĚŝƚLJ WŽǁĞƌ KW &ůŽǁƌĂƚĞ >ĞŶŐƚŚdžtŝĚƚŚdž
ƚĞŵƉĞƌĂƚƵƌĞ Σ ƐŝnjĞ Ŭt ĨĂŶƐ >ͬ^ ĐŽŶŶĞĐƚŝŽŶ ;ŬŐͿ
^^dͬϱϭΣ^d й >ͬ^ ,ĞŝŐŚƚ
Σ ƐŝnjĞŵŵ
,tϮϱ,Ͳϯ
,tϮϱ, ϯ ϯϴϬͲϰϭϱ
ϯϴϬ ϰϭϱ ϯ ϱϬ ϭϭ ϵϯ
ϭϭ͘ϵϯ ϵ ϲϰ
ϵ͘ϲϰ ϲϭ ϯϬ ϲϬ ϮϬ Ϯϱ͘ϰϯ
Ϯϱ ϰϯ ϰ͘ϵϴ
ϰ ϵϴ ϱ͘ϭϭ
ϱ ϭϭ Ϯ ϭϲϬϬ ϭϬ
ϭ͘Ϭ ϯϮ ϭϬϬ ϭϭϱϬdžϱϲϱdžϵϴϬ
ϭϭϱϬ dž ϱϲϱ dž ϵϴϬ
,tϰϬ,Ͳϯ ϯϴϬͲϰϭϱ ϯ ϱϬ ϭϴ͘ϵϲ ϭϱ͘ϰϲ ϲϭ ϯϬ ϲϬ Ϯϱ ϯϵ͘ϯϱ ϳ͘ϱϵ ϱ͘ϭϴ Ϯ ϮϯϬϬ ϭ͘ϱϳ ϱϬ͘ϴ ϭϳϬ ϭϳϱϬdžϴϬϬdžϴϮϱ
,tϱϬ,Ͳϯ ϯϴϬͲϰϭϱ ϯ ϱϬ Ϯϰ͘Ϯ ϭϵ͘Ϭϭ ϲϭ ϯϬ ϲϬ ϰϬ ϱϮ͘ϲϰ ϭϬ͘ϱϴ ϰ͘ϵϴ Ϯ ϰϳϬϬ Ϯ͘ϭ ϱϬ͘ϴ ϮϵϬ ϭϴϬϬdžϴϬϬdžϭϮϮϬ
,tϲϱ,Ͳϯ ϯϴϬͲϰϭϱ ϯ ϱϬ ϯϯ͘ϲ Ϯϳ͘ϳϬ ϲϭ ϯϬ ϲϬ ϲϯ ϲϴ͘Ϭϭ ϭϯ͘ϵϯ ϰ͘ϴϴ Ϯ ϰϳϬϬ Ϯ͘ϳϭ ϱϬ͘ϴ ϯϬϬ ϭϴϬϬdžϴϬϬdžϭϮϮϬ
,tϴϬ,Ͳϯ ϯϴϬͲϰϭϱ ϯ ϱϬ ϯϱ͘ϲ Ϯϴ͘ϲ ϲϭ ϯϬ ϲϬ ϲϯ ϳϴ͘ϳ ϭϱ͘ϯ ϱ͘ϭϰ Ϯ ϰϳϬϬ ϯ͘ϭϯ ϲϱ ϰϬϬ ϭϳϱϬdžϭϭϳϱdžϭϮϭϱ
,tϭϬϱ,Ͳϯ ϯϴϬͲϰϭϱ ϯ ϱϬ ϰϳ ϯϲ͘ϲϮ ϲϭ ϯϬ ϲϬ ϲϯ ϭϬϱ͘Ϯϴ ϮϬ͘ϲϰ ϱ͘ϭϬ Ϯ ϳϯϯϱ ϰ͘ϭϵ ϲϱ ϲϬϬ ϮϮϭϬdžϭϭϳϱdžϭϯϬϬ
,tϭϯϱ,Ͳϯ ϯϴϬͲϰϭϱ ϯ ϱϬ ϲϱ͘ϴ ϱϰ͘Ϭ ϲϭ ϯϬ ϲϬ ϭϬϬ ϭϯϲ͘ϬϮ Ϯϳ͘ϯϰ ϰ͘ϵϴ Ϯ ϳϯϯϱ ϱ͘ϰϭ ϲϱ ϲϱϬ ϮϮϭϬdžϭϭϳϱdžϭϯϬϬ

ZϭϯϰĂŵŽĚĞůƐǁŝƚŚŚŽƚŐĂƐŝŶũĞĐƚŝŽŶĚĞͲŝĐĞ͘

DĂdž͘>ĞĂǀŝŶŐ
ZĂƚĞĚ>ŽĂĚ ZĞůĂƚŝǀĞ tĂƚĞƌ tĂƚĞƌ ŝŵĞŶƐŝŽŶƐ;ŵŵͿ
tĂƚĞƌ ŵďŝĞŶƚ DŝŶ ,ĞĂƚŝŶŐ EŽ͗ŽĨ ŝƌĨůŽǁ tĞŝŐŚƚ
DŽĚĞů sŽůƚĂŐĞ WŚĂƐĞ ,Ğƌƚnj &>;&Ƶůů>ŽĂĚŵƉƐͿ ŵƉƐϭϮΣ ŚƵŵŝĚŝƚLJ WŽǁĞƌ KW &ůŽǁƌĂƚĞ ĐŽŶŶĞĐƚŝŽŶ >ĞŶŐƚŚdžtŝĚƚŚdž
ƚĞŵƉĞƌĂƚƵƌĞ Σ ƐŝnjĞ Ŭt ĨĂŶƐ >ͬ^ ;ŬŐͿ
^^dͬϱϭΣ^d й >ͬ^ ƐŝnjĞŵŵ ,ĞŝŐŚƚ
Σ
,tϮϬ,Ͳϯ,' ϯϴϬͲϰϭϱ ϯ ϱϬ ϭϰ͘ϰϴ ϭϬ͘ϭϰ ϲϱ ϯϬ ϲϬ ϮϬ ϮϬ͘ϰ ϰ͘Ϭϲϲ ϱ͘ϬϮ Ϯ ϭϲϬϬ Ϭ͘ϴϭ ϯϮ ϭϬϬ ϭϭϱϬdžϱϲϱdžϵϴϬ
,tϯϱ,Ͳϯ,' ϯϴϬͲϰϭϱ ϯ ϱϬ Ϯϯ͘ϰϴ ϭϯ͘ϵ ϲϱ ϯϬ ϲϬ ϯϮ ϯϱ͘ϬϮ ϲ͘ϴϳ ϱ͘ϭ Ϯ ϮϯϬϬ ϭ͘ϯϵ ϯϮ ϭϳϬ ϭϳϱϬdžϴϬϬdžϴϮϱ
,tϰϴ,Ͳϯ,' ϯϴϬͲϰϭϱ ϯ ϱϬ ϯϰ͘ϱϮ Ϯϰ͘ϴϰ ϲϱ ϯϬ ϲϬ ϰϬ ϰϳ͘ϲ ϵ͘ϰϲ ϰ͘ϵϰ Ϯ ϯϲϮϮ ϭ͘ϴϵ ϱϬ͘ϴ ϯϬϬ ϭϴϬϬdžϴϬϬdžϭϮϮϬ

ZϭϯϰĂŵŽĚĞůƐǁŝƚŚŽƵƚĚĞͲŝĐĞ͘

DĂdž͘>ĞĂǀŝŶŐ
ZĂƚĞĚ>ŽĂĚ ZĞůĂƚŝǀĞ tĂƚĞƌ tĂƚĞƌ ŝŵĞŶƐŝŽŶƐ;ŵŵͿ
tĂƚĞƌ ŵďŝĞŶƚ DŝŶ ,ĞĂƚŝŶŐ EŽ͗ŽĨ ŝƌĨůŽǁ tĞŝŐŚƚ
DŽĚĞů sŽůƚĂŐĞ WŚĂƐĞ ,Ğƌƚnj &>;&Ƶůů>ŽĂĚŵƉƐͿ ŵƉƐϭϮΣ ŚƵŵŝĚŝƚLJ WŽǁĞƌ KW &ůŽǁƌĂƚĞ ĐŽŶŶĞĐƚŝŽŶ >ĞŶŐƚŚdžtŝĚƚŚdž
ƚĞŵƉĞƌĂƚƵƌĞ Σ ƐŝnjĞ Ŭt ĨĂŶƐ >ͬ^ ;ŬŐͿ
^^dͬϱϭΣ^d й >ͬ^ ƐŝnjĞŵŵ ,ĞŝŐŚƚ
Σ
,tϮϬ,Ͳϯ ϯϴϬͲϰϭϱ ϯ ϱϬ ϭϰ͘ϰϴ ϭϬ͘ϭϰ ϲϱ ϯϬ ϲϬ ϮϬ ϮϬ͘ϰ ϰ͘Ϭϲϲ ϱ͘ϬϮ Ϯ ϭϲϬϬ Ϭ͘ϴϭ ϯϮ ϭϬϬ ϭϭϱϬdžϱϲϱdžϵϴϬ
,tϯϱ,Ͳϯ ϯϴϬͲϰϭϱ ϯ ϱϬ Ϯϯ͘ϰϴ ϭϯ͘ϵ ϲϱ ϯϬ ϲϬ ϯϮ ϯϱ͘ϬϮ ϲ͘ϴϳ ϱ͘ϭ Ϯ ϮϯϬϬ ϭ͘ϯϵ ϯϮ ϭϳϬ ϭϳϱϬdžϴϬϬdžϴϮϱ
,tϰϴ,Ͳϯ ϯϴϬͲϰϭϱ ϯ ϱϬ ϯϰ͘ϱϮ Ϯϰ͘ϴϰ ϲϱ ϯϬ ϲϬ ϰϬ ϰϳ͘ϲ ϵ͘ϰϲ ϰ͘ϵϰ Ϯ ϯϲϮϮ ϭ͘ϴϵ ϱϬ͘ϴ ϯϬϬ ϭϴϬϬdžϴϬϬdžϭϮϮϬ

DĂŶƵĨĂĐƚƵƌĞĚŝŶƵƐƚƌĂůŝĂďLJĐĐĞŶƚ ^ƵŵŵĂƌLJ,ŝŐŚŵďŝĞŶƚŚŽƚǁĂƚĞƌƋƵŝĐŬƌĞĨĞƌĞŶĐĞŐƵŝĚĞ͘džůƐdž
dŚŝƐƉĂŐĞŝƐůĞĨƚďůĂŶŬŝŶƚĞŶƚŝŽŶĂůůLJ͘
HOT WATER HEAT PUMP SPECIFICATIONS HW25HA-3HG COP GRAPH HW25HA-3HG

ELECTRICAL INPUT
Voltage/Phase 380 - 415 Volts / 3 Phase / 50 Hz
,tKW'ƌĂƉŚ
Full Load Amps Per Phase 11.93 Amps ϴ ϯϬ

ĂƉĂĐŝƚLJͬWŽǁĞƌ;ŬtͿ
Min. Circuit Size 20.0 Amps Ϯϱ
ϲ
Refrigerant R407C ϮϬ

KW
Nominal Heating capacity 25.43 kW  ϰ ϭϱ
Power input 4.98 kW ϭϬ
COP 5.11 Ϯ
ϱ
Noise Level 69 dBa @ 3 m
Ϭ Ϭ
Rated Load Amps @ 12°C SST / 51°C SCT 9.64 Amps
Ϭ ϭϬ ϮϬ ϯϬ ϰϬ ϱϬ
TECHNICAL DATA.
 Compressor Fan ŵďŝĞŶƚdĞŵƉĞƌĂƚƵƌĞ;ΣͿ
Make Copeland EBM-Papst
Type Scroll 20012 Axial KW ,ĞĂƚŝŶŐĂƉĂĐŝƚLJ;ŬtͿ WŽǁĞƌ;ŬtͿ
Number Per Unit 1 2
FLA (Full Load Amps) 10.65 Amps 0.64 Amps (Each)
Voltage / Phase 380 - 415 / 3 220 - 240 / 1
Pole/RPM 2/2,900 6/890
Air Flow N/A 1600 L/s
HEAT EXCHANGER (Water Side)
Type of Water Tube Copper
Design Shell and Tube
Flow Rate Excl. By Pass 1.01 L/s
UNIT CLEARANCES HW25HA-3HG
Max. Outlet Water Temp 61°C
Design Pressure Drop 80 kPa Direction Description Minimum Clearance Required
Max. Operating Pres. 2,450 kPa 1 Evaporator Coil 1000mm**
GENERAL INFORMATION 2 Water Connections 500mm
Water Connections 32mm Copper 3 Plain Back Nil
Drain 20mm PVC 4 Compressor Access 850mm
5 Top – Fan Discharge 3500mm
Defrost Hot Gas Injection
Cabinet Construction 1.2mm Stucco Aluminium **When units placed side by side allow 2000mm clearance between evaporator coils.
Approx. shipping weight 100 kg Rating Conditions: 30°C ambient, 60% RH, 39°C Water in, 45°C Water out
Size L x W x H 1150mm x 565mm x 980mm

Manufactured In Australia by Accent


      
Unit specifications subject to change without notice. ABN 28 062 383 224
,KdtdZ,dWhDW^W/&/d/KE^ ,tϰϬ,Ͳϯ,' KW'ZW, ,tϰϬ,Ͳϯ,'

>dZ/>/EWhd
Voltage/Phase 380 - 415 Volts / 3 Phase / 50 Hz ,tKW'ƌĂƉŚ
FLA Amps Per Phase 18.96 Amps
Min. Circuit Size 25.0 Amps ϴ ϱϬ

ĂƉĂĐŝƚLJͬWŽǁĞƌ;ŬtͿ
Refrigerant R407C ϲ ϰϬ
Nominal Heating Capacity 39.35 kW ϯϬ

KW
Power input 7.59 kW ϰ
ϮϬ
COP 5.18 Ϯ ϭϬ
Noise Level 62 dBa @ 3 m
Rated Load Amps @ 12°C SST / 51°C SCT 15.46 amps Ϭ Ϭ
d,E/>d͘ Ϭ ϭϬ ϮϬ ϯϬ ϰϬ ϱϬ
 ŽŵƉƌĞƐƐŽƌ &ĂŶ ŵďŝĞŶƚdĞŵƉĞƌĂƚƵƌĞ;ΣͿ
Make Copeland EBM-Papst
Type Scroll 20016 Axial KW ,ĞĂƚŝŶŐĂƉĂĐŝƚLJ;ŬtͿ WŽǁĞƌ;ŬtͿ
Number Per Unit 1 2
FLA ( Full Load Amps) 16.6 Amps 1.18 Amps (Each)
Voltage / Phase 380 - 415 / 3 220 – 240 / 1
Pole/RPM 2/2,900 6/890
Air Flow N/A 2300 L/s
,dy,E'Z;tĂƚĞƌ^ŝĚĞͿ
Type of Water Tube Copper
Design Shell in Tube
Flow Rate Excl. By Pass 1.57 l/s
Max. Outlet Temperature 61°C
Design Pressure Drop 80 kPa hE/d>ZE^ ,tϰϬ,Ͳϯ,'
Max. Operating Pres. 2450 kPa ŝƌĞĐƚŝŽŶ ĞƐĐƌŝƉƚŝŽŶ DŝŶŝŵƵŵůĞĂƌĂŶĐĞZĞƋƵŝƌĞĚ
'EZ>/E&KZDd/KE
1 Evaporator Coil 1000mm**
Water Connections 50.8 mm Copper
2 Water Connections 500mm
Drain 20mm PVC 3 Plain Back Nil
Defrost Hot Gas Injection 4 Compressor Access 850mm
Cabinet Construction 1.2mm Stucco Aluminium 5 Top – Fan Discharge 3500mm
Approx. shipping weight 220 kg
**When units placed side by side allow 2000mm clearance between evaporator coils.
Size L x W x H 1750mm x 800mm x 825mm
Rating Conditions: 30°C ambient, 60% RH, 39°C Water in, 45°C Water out

Manufactured In Australia by Accent

Unit specifications subject to change without notice. ABN 28 062 383 224
HOT WATER HEAT PUMP SPECIFICATIONS HW50HA-3HG COP GRAPH HW50HA-3HG

ELECTRICAL INPUT
Voltage/Phase 380 - 415 Volts / 3 Phase / 50 Hz ,tKW'ƌĂƉŚ
Full Load Amps Per Phase 24.2 Amps
Min. Circuit Size 40.0 Amps ϴ ϲϬ

ĂƉĂĐŝƚLJͬWŽǁĞƌ;ŬtͿ
Refrigerant R407C ϳ ϱϬ
ϲ
Nominal Heating capacity 52.64 kW ϰϬ
ϱ
Power input 10.58 kW

KW
ϰ ϯϬ
COP 4.98
ϯ ϮϬ
Noise Level 69 dBa @ 3 m
Ϯ
Rated Load Amps @ 12°C SST / 51°C SCT 19.01 Amps ϭϬ
ϭ
TECHNICAL DATA.
Ϭ Ϭ
Compressor Fan
Ϭ ϭϬ ϮϬ ϯϬ ϰϬ ϱϬ
Make Copeland EBM-Papst
Type Scroll 20018 Axial ŵďŝĞŶƚdĞŵƉĞƌĂƚƵƌĞ;ΣͿ
Number Per Unit 1 2
FLA (Full Load Amps) 21.8 Amps 1.2 Amps (Each) KW ,ĞĂƚŝŶŐĂƉĂĐŝƚLJ;ŬtͿ WŽǁĞƌ;ŬtͿ
Voltage / Phase 380 - 415 / 3 380 – 415 / 3
Pole/RPM 2/2,900 6/890
Air Flow N/A 4700 L/s
HEAT EXCHANGER (Water Side)
Type of Water Tube Copper
Design Shell and Tube
Flow Rate Excl. By Pass 2.1 L/s
Max. Outlet Water Temp 61°C
Design Pressure Drop 80 kPa
UNIT CLEARANCES HW50HA-3HG
Max. Operating Pres. 2,450 kPa
GENERAL INFORMATION Direction Description Minimum Clearance Required
Water Connections 50.8 mm Copper 1 Evaporator Coil 1000mm**
Drain 20mm Aluminium 2 Water Connections 500mm
Defrost Hot Gas Injection 3 Plain Back Nil
4 Compressor Access 850mm
Cabinet Construction 1.2mm Stucco Aluminium
5 Top – Fan Discharge 3500mm
Approx. shipping weight 290 kg
Size L x W x H 1800 x 800 x 1220 mm **When units placed side by side allow 2000mm clearance between evaporator coils.
Rating Conditions: 30°C ambient, 60% RH, 39°C Water in, 45°C Water out

Manufactured In Australia by Accent

Unit specifications subject to change without notice. ABN 28 062 383 224
HOT WATER HEAT PUMP SPECIFICATIONS HW65HA-3HG COP GRAPH HW65HA-3HG

ELECTRICAL INPUT
Voltage/Phase 380 - 415 Volts / 3 Phase / 50 Hz
,tKW'ƌĂƉŚ
Full Load Amps Per Phase 33.6 Amps ϴ ϴϬ

ĂƉĂĐŝƚLJͬWŽǁĞƌ;ŬtͿ
Min. Circuit Size 63.0 Amps ϳ ϳϬ
Refrigerant R407C Ambient 30°C Ambient 20°C ϲ ϲϬ
Nominal Heating capacity 68.01 kW 60.03 kW ϱ ϱϬ

KW
Power input 13.93 kW 13.8 kW ϰ ϰϬ
ϯ ϯϬ
COP 4.88 4.35
Ϯ ϮϬ
Noise Level 69 dBa @ 3 m
ϭ ϭϬ
Rated Load Amps @ 12°C SST / 51°C SCT 27.7 Amps
Ϭ Ϭ
TECHNICAL DATA.
Ϭ ϭϬ ϮϬ ϯϬ ϰϬ ϱϬ
Compressor Fan
Make Copeland Ziehl-ebm ŵďŝĞŶƚdĞŵƉĞƌĂƚƵƌĞ;ΣͿ
Type Scroll 20056 Axial
Number Per Unit 1 2 KW ,ĞĂƚŝŶŐĂƉĂĐŝƚLJ;ŬtͿ WŽǁĞƌ;ŬtͿ
FLA (Full Load Amps) 31.2 Amps 1.2 Amps (Each)
Voltage / Phase 380 - 415 / 3 380 - 415 /3
Pole/RPM 2/2,900 6/890
Air Flow N/A 4700 L/s
HEAT EXCHANGER (Water Side)
Type of Water Tube Copper
Design Shell and Tube
Flow Rate Excl. By Pass 2.71 L/s
Max. Outlet Water Temp 61°C
UNIT CLEARANCES HW65HA-3HG
Design Pressure Drop 80 kPa
Max. Operating Pres. 2,450 kPa Direction Description Minimum Clearance Required
GENERAL INFORMATION 1 Evaporator Coil 1000mm**
Water Connections 50.8 mm Copper 2 Water Connections 500mm
Drain 20mm Aluminium 3 Plain Back Nil
4 Compressor Access 850mm
Defrost Hot gas injection
5 Top – Fan Discharge 3500mm
Cabinet Construction 1.2mm Stucco Aluminium
**When units placed side by side allow 2000mm clearance between evaporator coils.
Approx. shipping weight 300 kg Rating Conditions: 30°C ambient, 60% RH, 39°C Water in, 45°C Water out
Size L x W x H 1800 x 800 x 1220 mm
Manufactured In Australia by Accent

Unit specifications subject to change without notice. ABN 28 062 383 224
HOT WATER HEAT PUMP SPECIFICATIONS HW80HA-3HG COP GRAPH HW80HA-3HG

ELECTRICAL INPUT
Voltage/Phase 380 - 415 Volts / 3 Phase / 50 Hz
,tKW'ƌĂƉŚ
Full Load Amps Per Phase 35.6 Amps ϴ ϭϬϬ

ĂƉĂĐŝƚLJͬWŽǁĞƌ;ŬtͿ
Min. Circuit Size 63.0 Amps ϳ
ϴϬ
Refrigerant R407C ϲ
ϱ ϲϬ

KW
Nominal Heating capacity 78.7 kW
ϰ
Power input 15.3 kW ϯ ϰϬ
COP 5.14 Ϯ
ϮϬ
Noise Level 69 dBa @ 3 m ϭ
Rated Load Amps @ 12°C SST / 51°C SCT 28.6 Amps Ϭ Ϭ
TECHNICAL DATA. Ϭ ϭϬ ϮϬ ϯϬ ϰϬ ϱϬ
Compressor Fan
ŵďŝĞŶƚdĞŵƉĞƌĂƚƵƌĞ;ΣͿ
Make Copeland EBM- Papst
Type Scroll 20016 Axial KW ,ĞĂƚŝŶŐĂƉĂĐŝƚLJ;ŬtͿ WŽǁĞƌ;ŬtͿ
Number Per Unit 2 2
FLA ( Full Load Amps) 16.6 Amps (Each) 1.2 Amps (Each)
Voltage / Phase 380 - 415 / 3 380 – 415 / 3
Pole/RPM 2/2,900 6/890
Air Flow N/A 4700 L/s
HEAT EXCHANGER (Water Side)
Type of Water Tube Copper
Design Shell and Tube
Flow Rate Excl. By Pass 3.13 L/s
Max. Outlet Water Temp 61°C UNIT CLEARANCES HW80HA-3HG
Design Pressure Drop 80 kPa
Direction Description Minimum Clearance Required
Max. Operating Pres. 2,450 kPa
1 Evaporator Coil 1000mm**
GENERAL INFORMATION
2 Water Connections 500mm
Water Connections 65 mm Copper
3 Evaporator Coil 1000mm**
Drain 20mm Aluminium 4 Compressor Access 850mm
Defrost Hot Gas Injection 5 Top – Fan Discharge 3500mm
Cabinet Construction 1.2mm Stucco Aluminium **When units placed side by side allow 2000mm clearance between evaporator coils.
Approx. shipping weight 400 kg Rating Conditions: 30°C ambient, 60% RH, 39°C Water in, 45°C Water out

Size L x W x H 1900 x 1000 x 1215 mm

Manufactured In Australia by Accent

Unit specifications subject to change without notice. ABN 28 062 383 224
HOT WATER HEAT PUMP SPECIFICATIONS HW105HA-3HG COP GRAPH HW105HA-3HG

ELECTRICAL INPUT
Voltage/Phase 380 - 415 Volts / 3 Phase / 50 Hz
,tKW'ƌĂƉŚ
Full Amps Per Phase 47 Amps ϴ ϭϰϬ

ĂƉĂĐŝƚLJͬWŽǁĞƌ;ŬtͿ
Min. Circuit Size 63.0 Amps ϳ ϭϮϬ
ϲ ϭϬϬ
Refrigerant R407C
ϱ
ϴϬ

KW
Nominal Heating capacity 105.28 kW ϰ
Power input 20.64 kW ϲϬ
ϯ
COP 5.10 Ϯ ϰϬ
Noise Level 69 dBa @ 3 m ϭ ϮϬ
Rated Load Amps @ 12°C SST / 51°C SCT 36.62 Amps Ϭ Ϭ
TECHNICAL DATA. Ϭ ϭϬ ϮϬ ϯϬ ϰϬ ϱϬ
Compressor Fan ŵďŝĞŶƚdĞŵƉĞƌĂƚƵƌĞ;ΣͿ
Make Copeland Zeihl- Abegg
Type Scroll 20018 Axial KW ,ĞĂƚŝŶŐĂƉĂĐŝƚLJ;ŬtͿ WŽǁĞƌ;ŬtͿ
Number Per Unit 2 2
FLA (Full Load Amps) 21.8 Amps (Each) 1.7 Amps (Each)
Voltage / Phase 380 - 415 / 3 380 - 415 / 3
Pole/RPM 2/2,900 6/890
Air Flow N/A 7335 L/s
HEAT EXCHANGER (Water Side)
Type of Water Tube Copper
Design Shell and Tube
Flow Rate 4.19 L/s
Max. Outlet Water Temp 61°C UNIT CLEARANCES HW105HA-3HG
Design Pressure Drop 80 kPa
Direction Description Minimum Clearance Required
Max. Operating Pres. 2,450 kPa
1 Evaporator Coil 1000mm**
GENERAL INFORMATION
2 Water Connections 500mm
Water Connections 65 mm Copper
3 Evaporator Coil 1000mm**
Drain 20mm Aluminium 4 Compressor Access 850mm
Defrost Hot Gas Injection 5 Top – Fan Discharge 3500mm
Cabinet Construction 1.2mm Stucco Aluminium
Approx. shipping weight 600 kg **When units placed side by side allow 2000mm clearance between evaporator coils.
Rating Conditions: 30°C ambient, 60% RH, 39°C Water in, 45°C Water out
Size L x W x H 2130 x 1130 x 1220 mm

Manufactured In Australia by Accent

Unit specifications subject to change without notice. ABN 28 062 383 224
HOT WATER HEAT PUMP SPECIFICATIONS HW135HA-3HG COP GRAPH HW135HA-3HG
Date: 13/7/2015
ELECTRICAL INPUT
Voltage/Phase 380 - 415 Volts / 3 Phase / 50 Hz
,tKW'ƌĂƉŚ
Full Amps Per Phase 65.8 Amps ϴ ϭϲϬ

ĂƉĂĐŝƚLJͬWŽǁĞƌ;ŬtͿ
Min. Circuit Size 100.0 Amps ϳ ϭϰϬ
ϲ ϭϮϬ
Refrigerant R407C
ϱ ϭϬϬ

KW
Nominal Heating capacity 136.02 kW ϰ ϴϬ
Power input 27.34 kW ϯ ϲϬ
COP 4.98 Ϯ ϰϬ
Noise Level 69 dBa @ 3 m ϭ ϮϬ
Rated Load Amps @ 12°C SST / 51°C SCT 54.0 Amps Ϭ Ϭ
TECHNICAL DATA. Ϭ ϭϬ ϮϬ ϯϬ ϰϬ ϱϬ
Compressor Fan ŵďŝĞŶƚdĞŵƉĞƌĂƚƵƌĞ;ΣͿ
Make Copeland Zeihl- Abegg
Type Scroll 20056 Axial KW ,ĞĂƚŝŶŐĂƉĂĐŝƚLJ;ŬtͿ WŽǁĞƌ;ŬtͿ
Number Per Unit 2 2
FLA (Full Load Amps) 31.2 Amps (Each) 1.7 Amps (Each)
Voltage / Phase 380 - 415 / 3 380 - 415 / 3
Pole/RPM 2/2,900 6/890
Air Flow N/A 7335 L/s
HEAT EXCHANGER (Water Side)
Type of Water Tube Copper
Design Shell and Tube
Flow Rate 5.41 L/s
Max. Outlet Water Temp 61°C UNIT CLEARANCES HW135HA-3HG
Design Pressure Drop 80 kPa
Direction Description Minimum Clearance Required
Max. Operating Pres. 2,450 kPa
GENERAL INFORMATION 1 Evaporator Coil 1000mm**
2 Water Connections 500mm
Water Connections 65 mm Copper
3 Evaporator Coil 1000mm**
Drain 20mm Aluminium
4 Compressor Access 850mm
Defrost Hot Gas Injection 5 Top – Fan Discharge 3500mm
Cabinet Construction 1.2mm Stucco Aluminium
Approx. shipping weight 650 kg **When units placed side by side allow 2000mm clearance between evaporator coils.
Rating Conditions: 30°C ambient, 60% RH, 39°C Water in, 45°C Water out
Size L x W x H 2210 x 1175 x 1300 mm

Manufactured In Australia by Accent

Unit specifications subject to change without notice. ABN 28 062 383 224
HOT WATER HEAT PUMP SPECIFICATIONS HW25HA-3 COP GRAPH HW25HA-3

ELECTRICAL INPUT
Voltage/Phase 380 - 415 Volts / 3 Phase / 50 Hz
,tKW'ƌĂƉŚ
Full Load Amps Per Phase 11.93 Amps ϴ ϯϬ

ĂƉĂĐŝƚLJͬWŽǁĞƌ;ŬtͿ
Min. Circuit Size 20.0 Amps Ϯϱ
ϲ
Refrigerant R407C ϮϬ

KW
Nominal Heating capacity 25.43 kW ϰ ϭϱ
Power input 4.98 kW ϭϬ
Ϯ
COP 5.11 ϱ
Noise Level 69 dBa @ 3 m Ϭ Ϭ
Rated Load Amps @ 12°C SST / 51°C SCT 9.62 Amps Ϭ ϭϬ ϮϬ ϯϬ ϰϬ ϱϬ
TECHNICAL DATA.
Compressor Fan ŵďŝĞŶƚdĞŵƉĞƌĂƚƵƌĞ;ΣͿ
Make Copeland EBM-Papst
KW ,ĞĂƚŝŶŐĂƉĂĐŝƚLJ;ŬtͿ WŽǁĞƌ;ŬtͿ
Type Scroll 20012 Propeller
Number Per Unit 1 2
FLA (Full Load Amps) 10.65 Amps 0.64 Amps (Each)
Voltage / Phase 380 - 415 / 3 220 - 240 / 1
Pole/RPM 2/2,900 6/890
Air Flow N/A 1600 L/s
HEAT EXCHANGER (Water Side)
Type of Water Tube Copper
Design Shell and Tube
Flow Rate Excl. By Pass 1.01 L/s
Max. Outlet Water Temp 61°C UNIT CLEARANCES HW25HA-3
Design Pressure Drop 80 kPa Direction Description Minimum Clearance Required
Max. Operating Pres. 2,450 kPa
1 Evaporator Coil 1000mm**
GENERAL INFORMATION
2 Water Connections 500mm
Water Connections 32mm Copper
3 Plain Back Nil
Drain 20mm PVC 4 Compressor Access 850mm
Minimum Ambient 15°C 5 Top – Fan Discharge 3500mm
Cabinet Construction 1.2mm Stucco Aluminium
Approx. shipping weight 100 kg **When units placed side by side allow 2000mm clearance between evaporator coils.
Rating Conditions: 30°C ambient, 60% RH, 39°C Water in, 45°C Water out
Size L x W x H 1150mm x 565mm x 980mm

Manufactured In Australia by Accent

Unit specifications subject to change without notice. ABN 28 062 383 224
,KdtdZ,dWhDW^W/&/d/KE^ ,tϰϬ,Ͳϯ KW'ZW, ,tϰϬ,Ͳϯ

>dZ/>/EWhd
Voltage/Phase 380 - 415 Volts / 3 Phase / 50 Hz
,tKW'ƌĂƉŚ
Full Load Amps Per Phase 18.96 Amps ϴ ϱϬ

ĂƉĂĐŝƚLJͬWŽǁĞƌ;ŬtͿ
Min. Circuit Size 25.0 Amps ϰϬ
ϲ
Refrigerant R407C
ϯϬ

KW
Nominal Heating Capacity 39.35 kW ϰ
ϮϬ
Power input 7.59 kW
Ϯ ϭϬ
COP 5.18
Noise Level 62 dBa @ 3 m Ϭ Ϭ
Rated Load Amps @ 12°C SST / 51°C SCT 15.46 amps Ϭ ϭϬ ϮϬ ϯϬ ϰϬ ϱϬ
d,E/>d͘
ŵďŝĞŶƚdĞŵƉĞƌĂƚƵƌĞ;ΣͿ
 ŽŵƉƌĞƐƐŽƌ &ĂŶ
Make Copeland Ziehl-ebm
KW ,ĞĂƚŝŶŐĂƉĂĐŝƚLJ;ŬtͿ WŽǁĞƌ;ŬtͿ
Type Scroll 20016 Axial
Number Per Unit 1 2
FLA (Full Load Amps) 16.6 Amps 0.84 Amps (Each)
Voltage / Phase 380 - 415 / 3 220 – 240 / 1
Pole/RPM 2/2,900 6/890
Air Flow N/A 2300 L/s
,dy,E'Z;tĂƚĞƌ^ŝĚĞͿ
Type of Water Tube Copper
Design Shell in Tube
Flow Rate Excl. By Pass 1.57 l/s
Max. Outlet Temperature 61°C hE/d>ZE^ ,tϰϬ,Ͳϯ
Design Pressure Drop 80 kPa
ŝƌĞĐƚŝŽŶ ĞƐĐƌŝƉƚŝŽŶ DŝŶŝŵƵŵůĞĂƌĂŶĐĞZĞƋƵŝƌĞĚ
Max. Operating Pres. 2450 kPa
'EZ>/E&KZDd/KE 1 Evaporator Coil 1000mm**
Water Connections 50.8 mm Copper 2 Water Connections 500mm
3 Plain Back Nil
Drain 20mm PVC
4 Compressor Access 850mm
Minimum Ambient Temperature 15°C
5 Top – Fan Discharge 3500mm
Cabinet Construction 1.2mm Stucco Aluminium
Approx. shipping weight 220 kg **When units placed side by side allow 2000mm clearance between evaporator coils.
Rating Conditions: 30°C ambient, 60% RH, 39°C Water in, 45°C Water out
Size L x W x H 1750mm x 800mm x 825mm

Manufactured In Australia by Accent

Unit specifications subject to change without notice. ABN 28 062 383 224
HOT WATER HEAT PUMP SPECIFICATIONS HW50HA-3 COP GRAPH HW50HA-3

ELECTRICAL INPUT
Voltage/Phase 380 - 415 Volts / 3 Phase / 50 Hz
,tKW'ƌĂƉŚ
Full Load Amps Per Phase 24.2 Amps ϴ ϲϬ

ĂƉĂĐŝƚLJͬWŽǁĞƌ;ŬtͿ
Min. Circuit Size 40.0 Amps ϳ ϱϬ
Refrigerant R407C ϲ
ϱ ϰϬ
Nominal Heating capacity 52.64 kW

KW
ϰ ϯϬ
Power input 10.58 kW
ϯ ϮϬ
COP 4.98 Ϯ
Noise Level 69 dBa @ 3 m ϭ ϭϬ
Rated Load Amps @ 12°C SST / 51°C SCT 19.01 Amps Ϭ Ϭ
TECHNICAL DATA. Ϭ ϭϬ ϮϬ ϯϬ ϰϬ ϱϬ
Compressor Fan
Make Copeland EBM-Papst ŵďŝĞŶƚdĞŵƉĞƌĂƚƵƌĞ;ΣͿ
Type Scroll 20018 Axial
KW ,ĞĂƚŝŶŐĂƉĂĐŝƚLJ;ŬtͿ WŽǁĞƌ;ŬtͿ
Number Per Unit 1 2
FLA (Full Load Amps) 21.8 Amps 1.2 Amps (Each)
Voltage / Phase 380 - 415 / 3 380 – 415 / 3
Pole/RPM 2/2,900 6/890
Air Flow N/A 4700 L/s
HEAT EXCHANGER (Water Side)
Type of Water Tube Copper
Design Shell and Tube
Flow Rate Excl. By Pass 2.1 L/s
Max. Outlet Water Temp 61°C UNIT CLEARANCES HW50HA-3
Design Pressure Drop 80 kPa
Direction Description Minimum Clearance Required
Max. Operating Pres. 2,450 kPa
GENERAL INFORMATION 1 Evaporator Coil 1000mm**
2 Water Connections 500mm
Water Connections 50.8 mm Copper
3 Plain Back Nil
Drain 20mm Aluminium
4 Compressor Access 850mm
Minimum Ambient 15°C 5 Top – Fan Discharge 3500mm
Cabinet Construction 1.2mm Stucco Aluminium
Approx. shipping weight 290 kg **When units placed side by side allow 2000mm clearance between evaporator coils.
Rating Conditions: 30°C ambient, 60% RH, 39°C Water in, 45°C Water out
Size L x W x H 1800 x 800 x 1220 mm

Manufactured In Australia by Accent

Unit specifications subject to change without notice. ABN 28 062 383 224
HOT WATER HEAT PUMP SPECIFICATIONS HW65HA-3 COP GRAPH HW65HA-3

ELECTRICAL INPUT
Voltage/Phase 380-415 Volts / 3 Phase / 50 Hz
,tKW'ƌĂƉŚ
Full Load Amps Per Phase 33.6 Amps ϴ ϴϬ

ĂƉĂĐŝƚLJͬWŽǁĞƌ;ŬtͿ
Min. Circuit Size 63.0 Amps ϳ ϳϬ
Refrigerant R407C ϲ ϲϬ
ϱ ϱϬ
Nominal Heating capacity 67.98 kW

KW
ϰ ϰϬ
Power input 13.48 kW
ϯ ϯϬ
COP 5.04 Ϯ ϮϬ
Noise Level 69 dBa @ 3 m ϭ ϭϬ
Rated Load Amps @ 12°C SST / 51°C SCT 28.62 Amps Ϭ Ϭ
TECHNICAL DATA. Ϭ ϭϬ ϮϬ ϯϬ ϰϬ ϱϬ
Compressor Fan
Make Copeland EBM-Papst ŵďŝĞŶƚdĞŵƉĞƌĂƚƵƌĞ;ΣͿ
Type Scroll 20056 Axial
KW ,ĞĂƚŝŶŐĂƉĂĐŝƚLJ;ŬtͿ WŽǁĞƌ;ŬtͿ
Number Per Unit 1 2
FLA ( Full Load Amps) 31.2 Amps 1.2 Amps (Each)
Voltage / Phase 380-415 / 3 380-415 / 3
Pole/RPM 2/2,900 6/890
Air Flow N/A 3622 L/s
HEAT EXCHANGER (Water Side)
Type of Water Tube Copper
Design Shell and Tube
Flow Rate Excl. By Pass 2.7 L/s
Max. Outlet Water Temp 61°C UNIT CLEARANCES HW65HA-3
Design Pressure Drop 80 kPa
Direction Description Minimum Clearance Required
Max. Operating Pres. 2,450 kPa
GENERAL INFORMATION 1 Evaporator Coil 1000mm**
2 Water Connections 500mm
Water Connections 50.8 mm Copper
3 Plain Back Nil
Drain 20mm Aluminium
4 Compressor Access 850mm
Minimum Ambient Temperature 15°C 5 Top – Fan Discharge 3500mm
Cabinet Construction 1.2mm Stucco Aluminium
Approx. shipping weight 300 kg **When units placed side by side allow 2000mm clearance between evaporator coils.
Rating Conditions: 30°C ambient, 60% RH, 39°C Water in, 45°C Water out
Size L x W x H 1800 x 800 x 1220 mm

Manufactured In Australia by Accent

Unit specifications subject to change without notice. ABN 28 062 383 224
HOT WATER HEAT PUMP SPECIFICATIONS HW80HA-3 COP GRAPH HW80HA-3

ELECTRICAL INPUT
Voltage/Phase 380 - 415 Volts / 3 Phase / 50 Hz
,tKW'ƌĂƉŚ
Full Load Amps Per Phase 35.6 Amps ϴ ϭϬϬ

ĂƉĂĐŝƚLJͬWŽǁĞƌ;ŬtͿ
Min. Circuit Size 63.0 Amps ϳ
ϴϬ
ϲ
Refrigerant R407C
ϱ ϲϬ

KW
Nominal Heating capacity 78.7 kW
ϰ
Power input 15.3 kW ϯ ϰϬ
COP 5.14 Ϯ
ϮϬ
Noise Level 69 dBa @ 3 m ϭ
Rated Load Amps @ 12°C SST / 51°C SCT 28.6 Amps Ϭ Ϭ
TECHNICAL DATA. Ϭ ϭϬ ϮϬ ϯϬ ϰϬ ϱϬ
Compressor Fan ŵďŝĞŶƚdĞŵƉĞƌĂƚƵƌĞ;ΣͿ
Make Copeland EBM- Papst
Type Scroll 20016 Axial KW ,ĞĂƚŝŶŐĂƉĂĐŝƚLJ;ŬtͿ WŽǁĞƌ;ŬtͿ
Number Per Unit 2 2
FLA (Full Load Amps) 16.6 Amps (Each) 1.2 Amps (Each)
Voltage / Phase 380 - 415 / 3 380 – 415 / 3
Pole/RPM 2/2,900 6/890
Air Flow N/A 4700 L/s
HEAT EXCHANGER (Water Side)
Type of Water Tube Copper
Design Shell and Tube
Flow Rate Excl. By Pass 3.13 L/s
Max. Outlet Water Temp 61°C UNIT CLEARANCES HW80HA-3
Design Pressure Drop 80 kPa Direction Description Minimum Clearance Required
Max. Operating Pres. 2,450 kPa
1 Evaporator Coil 1000mm**
GENERAL INFORMATION
2 Water Connections 500mm
Water Connections 65 mm Copper 3 Evaporator Coil 1000mm**
Drain 20mm Aluminium 4 Compressor Access 850mm
Minimum Ambient 15°C 5 Top – Fan Discharge 3500mm
Cabinet Construction 1.2mm Stucco Aluminium
**When units placed side by side allow 2000mm clearance between evaporator coils.
Approx. shipping weight 400 kg Rating Conditions: 30°C ambient, 60% RH, 39°C Water in, 45°C Water out
Size L x W x H 1750 x 1175 x 1215 mm

Manufactured In Australia by Accent

Unit specifications subject to change without notice. ABN 28 062 383 224
HOT WATER HEAT PUMP SPECIFICATIONS HW105HA-3 COP GRAPH HW105HA-3

ELECTRICAL INPUT
Voltage/Phase 380 - 415 Volts / 3 Phase / 50 Hz
,tKW'ƌĂƉŚ
Full Load Amps Per Phase 47.0 Amps ϴ ϭϰϬ

ĂƉĂĐŝƚLJͬWŽǁĞƌ;ŬtͿ
Min. Circuit Size 63.0 Amps ϳ ϭϮϬ
ϲ ϭϬϬ
Refrigerant R407C
ϱ
ϴϬ

KW
Nominal Heating capacity 105.28 kW ϰ
Power input 20.64 kW ϲϬ
ϯ
COP 5.10 Ϯ ϰϬ
Noise Level 69 dBa @ 3 m ϭ ϮϬ
Rated Load Amps @ 12°C SST / 51°C SCT 36.62 Amps Ϭ Ϭ
TECHNICAL DATA. Ϭ ϭϬ ϮϬ ϯϬ ϰϬ ϱϬ
Compressor Fan ŵďŝĞŶƚdĞŵƉĞƌĂƚƵƌĞ;ΣͿ
Make Copeland Zeihl- Abegg
Type Scroll 20018 Propeller KW ,ĞĂƚŝŶŐĂƉĂĐŝƚLJ;ŬtͿ WŽǁĞƌ;ŬtͿ
Number Per Unit 2 2
FLA (Full Load Amps) 21.8 Amps (Each) 1.7 Amps (Each)
Voltage / Phase 380 - 415 / 3 380 - 415 / 3
Pole/RPM 2/2,900 6/890
Air Flow N/A 7335 L/s
HEAT EXCHANGER (Water Side)
Type of Water Tube Copper
Design Shell and Tube
Flow Rate 4.19 L/s
Max. Outlet Water Temp 61°C UNIT CLEARANCES HW105HA-3
Design Pressure Drop 80 kPa
Direction Description Minimum Clearance Required
Max. Operating Pres. 2,450 kPa
1 Evaporator Coil 1000mm**
GENERAL INFORMATION
2 Water Connections 500mm
Water Connections 65 mm Copper
3 Evaporator Coil 1000mm**
Drain 20mm Aluminium 4 Compressor Access 850mm
Minimum Ambient 15°C 5 Top – Fan Discharge 3500mm
Cabinet Construction 1.2mm Stucco Aluminium
Approx. shipping weight 600 kg **When units placed side by side allow 2000mm clearance between evaporator coils.
Rating Conditions: 30°C ambient, 60% RH, 39°C Water in, 45°C Water out
Size L x W x H 2210 x 1175 x 1300 mm

Manufactured In Australia by Accent

Unit specifications subject to change without notice. ABN 28 062 383 224
HOT WATER HEAT PUMP SPECIFICATIONS HW135HA-3 COP GRAPH HW135HA-3

ELECTRICAL INPUT
Voltage/Phase 380 - 415 Volts / 3 Phase / 50 Hz
,tKW'ƌĂƉŚ
Full Load Amps Per Phase 65.8 Amps ϴ ϭϲϬ

ĂƉĂĐŝƚLJͬWŽǁĞƌ;ŬtͿ
Min. Circuit Size 100.0 Amps ϳ ϭϰϬ
ϲ ϭϮϬ
Refrigerant R407C
ϱ ϭϬϬ

KW
Nominal Heating capacity 136.02 kW ϰ ϴϬ
Power input 27.34 kW ϯ ϲϬ
COP 4.98 Ϯ ϰϬ
Noise Level 69 dBa @ 3 m ϭ ϮϬ
Rated Load Amps @ 12°C SST / 51°C SCT 54.0 Amps Ϭ Ϭ
TECHNICAL DATA. Ϭ ϭϬ ϮϬ ϯϬ ϰϬ ϱϬ
Compressor Fan ŵďŝĞŶƚdĞŵƉĞƌĂƚƵƌĞ;ΣͿ
Make Copeland Zeihl- Abegg
Type Scroll 20056 Axial KW ,ĞĂƚŝŶŐĂƉĂĐŝƚLJ;ŬtͿ WŽǁĞƌ;ŬtͿ
Number Per Unit 2 2
FLA ( Full Load Amps) 31.2 Amps (Each) 1.7 Amps (Each)
Voltage / Phase 380 - 415 / 3 380 - 415 / 3
Pole/RPM 2/2,900 6/890
Air Flow N/A 7335 L/s
HEAT EXCHANGER (Water Side)
Type of Water Tube Copper
Design Shell and Tube
Flow Rate 5.41 L/s
Max. Outlet Water Temp 61°C UNIT CLEARANCES HW135HA-3
Design Pressure Drop 80 kPa
Direction Description Minimum Clearance Required
Max. Operating Pres. 2,450 kPa
GENERAL INFORMATION 1 Evaporator Coil 1000mm**
2 Water Connections 500mm
Water Connections 65 mm Copper
3 Evaporator Coil 1000mm**
Drain 20mm Aluminium
4 Compressor Access 850mm
Minimum Ambient 15°C 5 Top – Fan Discharge 3500mm
Cabinet Construction 1.2mm Stucco Aluminium
Approx. shipping weight 650 kg **When units placed side by side allow 2000mm clearance between evaporator coils.
Rating Conditions: 30°C ambient, 60% RH, 39°C Water in, 45°C Water out
Size L x W x H 2210 x 1175 x 1300 mm

Manufactured In Australia by Accent

Unit specifications subject to change without notice. ABN 28 062 383 224
HOT WATER HEAT PUMP SPECIFICATIONS HW20DHA-3HG COP GRAPH HW20DHA-3HG

ELECTRICAL INPUT
Voltage/Phase 380 - 415 Volts / 3 Phase / 50 Hz
,tKW'ƌĂƉŚ
Full Load Amps Per Phase 14.48 Amps ϴ Ϯϱ

ĂƉĂĐŝƚLJͬWŽǁĞƌ;ŬtͿ
Min. Circuit Size 20.0 Amps ϮϬ
ϲ
Refrigerant R134a ϭϱ

KW
Nominal Heating capacity 20.4 kW  ϰ
ϭϬ
Power input 4.066 kW Ϯ ϱ
COP 5.02
Noise Level 69 dBa @ 3 m Ϭ Ϭ
Rated Load Amps @ 12°C SST / 51°C SCT 10.14 Amps Ϭ ϭϬ ϮϬ ϯϬ ϰϬ ϱϬ
TECHNICAL DATA. ŵďŝĞŶƚdĞŵƉĞƌĂƚƵƌĞ;ΣͿ
 Compressor Fan
Make Copeland EBM-Papst KW ,ĞĂƚŝŶŐĂƉĂĐŝƚLJ;ŬtͿ WŽǁĞƌ;ŬtͿ
Type Scroll 20014 Axial
Number Per Unit 1 2
FLA (Full Load Amps) 13.2 Amps 0.64 Amps (Each)
Voltage / Phase 380 - 415 / 3 220 - 240 / 1
Pole/RPM 2/2,900 6/890
Air Flow N/A 1600 L/s
HEAT EXCHANGER (Water Side)
Type of Water Tube Copper
Design Shell and Tube
Flow Rate Excl. By Pass 0.81 L/s
Max. Outlet Water Temp 65°C
UNIT CLEARANCES HW20DHA-3HG
Design Pressure Drop 80 kPa
Direction Description Minimum Clearance Required
Max. Operating Pres. 2,450 kPa
GENERAL INFORMATION 1 Evaporator Coil 1000mm**
Water Connections 32mm Copper 2 Water Connections 500mm
Drain 20mm PVC 3 Plain Back Nil
4 Compressor Access 850mm
Defrost Hot Gas Injection
5 Top – Fan Discharge 3500mm
Cabinet Construction 1.2mm Stucco Aluminium
Approx. shipping weight 100 kg **When units placed side by side allow 2000mm clearance between evaporator coils.
Size L x W x H 1150mm x 565mm x 980mm Rating Conditions: 30°C ambient, 60% RH, 39°C Water in, 45°C Water out

Manufactured In Australia by Accent


      
Unit specifications subject to change without notice. ABN 28 062 383 224
,KdtdZ,dWhDW^W/&/d/KE^ ,tϯϱ,Ͳϯ,' KW'ZW, ,tϯϱ,Ͳϯ,'

>dZ/>/EWhd
Voltage/Phase 380 - 415 Volts / 3 Phase / 50 Hz
,tKW'ƌĂƉŚ
Full Load Amps Per Phase 23.48 Amps ϴ ϱϬ

ĂƉĂĐŝƚLJͬWŽǁĞƌ;ŬtͿ
Min. Circuit Size 32 Amps ϰϬ
ϲ
Refrigerant R134a
ϯϬ

KW
Nominal Heating Capacity 35.02 kW  ϰ
ϮϬ
Power input 6.87 kW
Ϯ ϭϬ
COP 5.10
Noise Level 62 dBa @ 3 m Ϭ Ϭ
Rated Load Amps @ 12°C SST / 51°C SCT 13.9 amps Ϭ ϭϬ ϮϬ ϯϬ ϰϬ ϱϬ
d,E/>d͘
ŵďŝĞŶƚdĞŵƉĞƌĂƚƵƌĞ;ΣͿ
 ŽŵƉƌĞƐƐŽƌ &ĂŶ
Make Copeland EBM-Papst
^^d ,ĞĂƚŝŶŐĂƉĂĐŝƚLJ;ŬtͿ WŽǁĞƌ;ŬtͿ
Type Scroll 20018 Axial
Number Per Unit 1 2
FLA (Full Load Amps) 21.8 Amps 0.84 Amps (Each)
Voltage / Phase 380 - 415 / 3 220 - 240 / 1
Pole/RPM 2/2,900 6/890
Air Flow N/A 2300 L/s
,dy,E'Z;tĂƚĞƌ^ŝĚĞͿ
Type of Water Tube Copper
Design Shell in Tube
Flow Rate Excl. By Pass 1.39 l/s
Max. Outlet Temperature 65°C hE/d>ZE^ ,tϯϱ,Ͳϯ,'
Design Pressure Drop 80 kPa
ŝƌĞĐƚŝŽŶ ĞƐĐƌŝƉƚŝŽŶ DŝŶŝŵƵŵůĞĂƌĂŶĐĞZĞƋƵŝƌĞĚ
Max. Operating Pres. 2450 kPa
'EZ>/E&KZDd/KE 1 Evaporator Coil 1000mm**
Water Connections 32 mm Copper 2 Water Connections 500mm
3 Plain Back Nil
Drain 20mm PVC
4 Compressor Access 850mm
Defrost Hot Gas Injection
5 Top – Fan Discharge 3500mm
Cabinet Construction 1.2mm Stucco Aluminium
Approx. shipping weight 170 kg **When units placed side by side allow 2000mm clearance between evaporator coils.
Rating Conditions: 30°C ambient, 60% RH, 39°C Water in, 45°C Water out
Size L x W x H 1750mm x 800mm x 825mm

Manufactured In Australia by Accent


      
Unit specifications subject to change without notice. ABN 28 062 383 224
HOT WATER HEAT PUMP SPECIFICATIONS HW48DHA-3HG COP GRAPH HW48DHA-3HG

ELECTRICAL INPUT
Voltage/Phase 380 - 415 Volts / 3 Phase / 50 Hz
,tKW'ƌĂƉŚ
Full Load Amps Per Phase 34.52 Amps ϴ ϲϬ

ĂƉĂĐŝƚLJͬWŽǁĞƌ;ŬtͿ
Min. Circuit Size 40 Amps ϳ ϱϬ
Refrigerant R134a ϲ
ϱ ϰϬ
Nominal Heating capacity 47.6 kW 

KW
ϰ ϯϬ
Power input 9.46 kW
ϯ ϮϬ
COP 4.94 Ϯ
Noise Level 69 dBa @ 3 m ϭ ϭϬ
Rated Load Amps @ 12°C SST / 51°C SCT 24.84 Amps Ϭ Ϭ
TECHNICAL DATA. Ϭ ϭϬ ϮϬ ϯϬ ϰϬ ϱϬ
 Compressor Fan
Make Copeland EBM-Papst
ŵďŝĞŶƚdĞŵƉĞƌĂƚƵƌĞ;ΣͿ
Type Scroll 20056 Propeller
KW ,ĞĂƚŝŶŐĂƉĂĐŝƚLJ;ŬtͿ WŽǁĞƌ;ŬtͿ
Number Per Unit 1 2
FLA (Full Load Amps) 31.2 Amps 1.2 Amps (Each)
Voltage / Phase 380 - 415 / 3 380 - 415 / 3
Pole/RPM 2/2,900 6/890
Air Flow N/A 4700 L/s
HEAT EXCHANGER (Water Side)
Type of Water Tube Copper
Design Shell and Tube
Flow Rate Excl. By Pass 1.89 L/s
Max. Outlet Water Temp 65°C UNIT CLEARANCES HW48DHA-3HG
Design Pressure Drop 80 kPa
Direction Description Minimum Clearance Required
Max. Operating Pres. 2,450 kPa
GENERAL INFORMATION 1 Evaporator Coil 1000mm**
2 Water Connections 500mm
Water Connections 50.8 mm Copper
3 Plain Back Nil
Drain 20mm Aluminium 4 Compressor Access 850mm
Defrost Hot Gas Injection 5 Top – Fan Discharge 3500mm
Cabinet Construction 1.2mm Stucco Aluminium
Approx. shipping weight 300 kg **When units placed side by side allow 2000mm clearance between evaporator coils.
Rating Conditions: 30°C ambient, 60% RH, 39°C Water in, 45°C Water out
Size L x W x H 1800 x 800 x 1220 mm

Manufactured In Australia by Accent


      
Unit specifications subject to change without notice. ABN 28 062 383 224
HOT WATER HEAT PUMP SPECIFICATIONS HW20DHA-3 COP GRAPH HW20DHA-3

ELECTRICAL INPUT
Voltage/Phase 380 - 415 Volts / 3 Phase / 50 Hz
,tKW'ƌĂƉŚ
Full Load Amps Per Phase 14.48 Amps ϴ Ϯϱ

ĂƉĂĐŝƚLJͬWŽǁĞƌ;ŬtͿ
Min. Circuit Size 20.0 Amps ϮϬ
ϲ
Refrigerant R134a ϭϱ

KW
Nominal Heating capacity 20.4 kW  ϰ
ϭϬ
Power input 4.066 kW Ϯ ϱ
COP 5.02
Noise Level 69 dBa @ 3 m Ϭ Ϭ
Rated Load Amps @ 12°C SST / 51°C SCT 10.14 Amps Ϭ ϭϬ ϮϬ ϯϬ ϰϬ ϱϬ
TECHNICAL DATA. ŵďŝĞŶƚdĞŵƉĞƌĂƚƵƌĞ;ΣͿ
 Compressor Fan
Make Copeland EMB-Papst KW ,ĞĂƚŝŶŐĂƉĂĐŝƚLJ;ŬtͿ WŽǁĞƌ;ŬtͿ
Type Scroll Axial
Number Per Unit 1 2
FLA (Full Load Amps) 13.2 Amps 0.64 Amps (Each)
Voltage / Phase 380 - 415 / 3 220 – 240 / 1
Pole/RPM 2/2,900 6/890
Air Flow N/A 1600 L/s
HEAT EXCHANGER (Water Side)
Type of Water Tube Copper
Design Shell and Tube
Flow Rate Excl. By Pass 0.81 L/s
Max. Outlet Water Temp 65°C
UNIT CLEARANCES HW20DHA-3
Design Pressure Drop 80 kPa
Direction Description Minimum Clearance Required
Max. Operating Pres. 2,450 kPa
GENERAL INFORMATION 1 Evaporator Coil 1000mm**
Water Connections 32mm Copper 2 Water Connections 500mm
Drain 20mm PVC 3 Plain Back Nil
4 Compressor Access 850mm
Minimum Ambient 15°C
5 Top – Fan Discharge 3500mm
Cabinet Construction 1.2mm Stucco Aluminium
Approx. shipping weight 100 kg **When units placed side by side allow 2000mm clearance between evaporator coils.
Size L x W x H 1150mm x 565mm x 980mm Rating Conditions: 30°C ambient, 60% RH, 39°C Water in, 45°C Water out

Manufactured In Australia by Accent


      
Unit specifications subject to change without notice. ABN 28 062 383 224
,KdtdZ,dWhDW^W/&/d/KE^ ,tϯϱ,Ͳϯ KW'ZW, ,tϯϱ,Ͳϯ

>dZ/>/EWhd
Voltage/Phase 380 – 415 Volts / 3 Phase / 50 Hz
,tKW'ƌĂƉŚ
Full Load Amps Per Phase 23.48 Amps ϴ ϱϬ

ĂƉĂĐŝƚLJͬWŽǁĞƌ;ŬtͿ
Min. Circuit Size 32.0 Amps ϰϬ
ϲ
Refrigerant R134a
ϯϬ

KW
Nominal Heating Capacity 35.02 kW  ϰ
ϮϬ
Power input 6.87 kW
Ϯ ϭϬ
COP 5.10
Noise Level 62 dBa @ 3 m Ϭ Ϭ
Rated Load Amps @ 12°C SST / 51°C SCT 13.9 amps Ϭ ϭϬ ϮϬ ϯϬ ϰϬ ϱϬ
d,E/>d͘
ŵďŝĞŶƚdĞŵƉĞƌĂƚƵƌĞ;ΣͿ
 ŽŵƉƌĞƐƐŽƌ &ĂŶ
Make Copeland Ziehl-ebm
^^d ,ĞĂƚŝŶŐĂƉĂĐŝƚLJ;ŬtͿ WŽǁĞƌ;ŬtͿ
Type Scroll 20018 Propeller
Number Per Unit 1 2
FLA (Full Load Amps) 21.8 Amps 0.84 Amps (Each)
Voltage / Phase 380 - 415 / 3 220 - 240 / 1
Pole/RPM 2/2,900 6/890
Air Flow N/A 2300 L/s
,dy,E'Z;tĂƚĞƌ^ŝĚĞͿ
Type of Water Tube Copper
Design Shell in Tube
Flow Rate Excl. By Pass 1.39 l/s
Max. Outlet Temperature 65°C hE/d>ZE^ ,tϯϱ,Ͳϯ
Design Pressure Drop 80 kPa
ŝƌĞĐƚŝŽŶ ĞƐĐƌŝƉƚŝŽŶ DŝŶŝŵƵŵůĞĂƌĂŶĐĞZĞƋƵŝƌĞĚ
Max. Operating Pres. 2450 kPa
'EZ>/E&KZDd/KE 1 Evaporator Coil 1000mm**
Water Connections 32 mm Copper 2 Water Connections 500mm
3 Plain Back Nil
Drain 20mm PVC
4 Compressor Access 850mm
Minimum Ambient Temperature 15°C
5 Top – Fan Discharge 3500mm
Cabinet Construction 1.2mm Stucco Aluminium
Approx. shipping weight 170 kg **When units placed side by side allow 2000mm clearance between evaporator coils.
Rating Conditions: 30°C ambient, 60% RH, 39°C Water in, 45°C Water out
Size L x W x H 1750mm x 800mm x 825mm

Manufactured In Australia by Accent


      
Unit specifications subject to change without notice. ABN 28 062 383 224
HOT WATER HEAT PUMP SPECIFICATIONS HW48DHA-3 COP GRAPH HW48DHA-3

ELECTRICAL INPUT
Voltage/Phase 380 - 415 Volts / 3 Phase / 50 Hz
,tKW'ƌĂƉŚ
Full Load Amps Per Phase 34.52 Amps ϴ ϲϬ

ĂƉĂĐŝƚLJͬWŽǁĞƌ;ŬtͿ
Min. Circuit Size 40.0 Amps ϳ ϱϬ
Refrigerant R134a ϲ
ϱ ϰϬ
Nominal Heating capacity 47.6 kW 

KW
ϰ ϯϬ
Power input 9.46 kW
ϯ ϮϬ
COP 4.94 Ϯ
Noise Level 69 dBa @ 3 m ϭ ϭϬ
Rated Load Amps @ 12°C SST / 51°C SCT 24.84 Amps Ϭ Ϭ
TECHNICAL DATA. Ϭ ϭϬ ϮϬ ϯϬ ϰϬ ϱϬ
 Compressor Fan
Make Copeland EBM-Papst ŵďŝĞŶƚdĞŵƉĞƌĂƚƵƌĞ;ΣͿ
Type Scroll 20056 Propeller
KW ,ĞĂƚŝŶŐĂƉĂĐŝƚLJ;ŬtͿ WŽǁĞƌ;ŬtͿ
Number Per Unit 1 2
FLA (Full Load Amps) 31.2 Amps 1.2 Amps (Each)
Voltage / Phase 280 - 415 / 3 380 – 415 / 3
Pole/RPM 2/2,900 6/890
Air Flow N/A 4700 L/s
HEAT EXCHANGER (Water Side)
Type of Water Tube Copper
Design Shell and Tube
Flow Rate Excl. By Pass 1.89 L/s
Max. Outlet Water Temp 65°C UNIT CLEARANCES HW48DHA-3
Design Pressure Drop 80 kPa
Direction Description Minimum Clearance Required
Max. Operating Pres. 2,450 kPa
GENERAL INFORMATION 1 Evaporator Coil 1000mm**
2 Water Connections 500mm
Water Connections 50.8 mm Copper
3 Plain Back Nil
Drain 20mm Aluminium
4 Compressor Access 850mm
Minimum Ambient Temperature 15°C 5 Top – Fan Discharge 3500mm
Cabinet Construction 1.2mm Stucco Aluminium
Approx. shipping weight 300 kg **When units placed side by side allow 2000mm clearance between evaporator coils.
Rating Conditions: 30°C ambient, 60% RH, 39°C Water in, 45°C Water out
Size L x W x H 1800 x 800 x 1220 mm

Manufactured In Australia by Accent


      
Unit specifications subject to change without notice. ABN 28 062 383 224

You might also like