f5Linkage 3.

1 Document DB625-2725-00-01 Page 1 of 16

TECHNICAL DATA BOOK


for
2.725" RNQN STANDING VALVE
PW 625-2725-00-01

THIS DATA BOOK IS THE PROPERTY OF PETROLINE WELLSYSTEMS


LTD AND MAY NOT BE REPRODUCED IN WHOLE OR IN PART
WITHOUT PRIOR PERMISSION. IT CONTAINS CONFIDENTIAL
INFORMATION AND IS SUBMITTED FOR A SPECIFIC PURPOSE AND
THE RECIPIENT AGREES BY ACCEPTING IT NOT TO DISCLOSE ANY
INFORMATION REGARDING IT TO ANY UNAUTHORISED PERSON OR
USE IT FOR ANY OTHER PURPOSE THAN THAT IT WAS INTENDED
FOR. ALL PATENT RIGHTS HERETO ARE EXPRESSLY RESERVED BY
PETROLINE WELLSYSTEMS LTD.

PETROLINE WELLSYSTEMS LTD.,


OFFSHORE TECHNOLOGY PARK
CLAYMORE DRIVE
BRIDGE OF DON
ABERDEEN AB23 8GD
SCOTLAND UK
TEL: (01224) 423423 FAX: (01224) 423200

Prepared By gib1 02nd July 99


Rev 0001 Section 1 Page 1 of 3 Approved By adg1 02nd July 99
Linkage 3.1 Document DB625-2725-00-01 Page 2 of 16
PETROLINE WELLSYSTEMS LTD

TABLE OF CONTENTS

Section

Introduction 1

Technical Information for Standing Valve 2

Technical Drawing for Standing Valve 2

Assembly Drawing for Standing Valve 3

Parts List for Standing Valve 3

Assembly Instructions for Standing Valve 3

Assembly Drawing for Standing Valve Sub Assembly 3

Parts List for Standing Valve Sub Assembly 3

Assembly Instructions for Standing Valve Sub Assembly 3

Operating Requirements 4

General Illustration of Std. Valve in the Running Position. 4

General Illustration of Std. Valve in the Set Position. 4

General Illustration of Std. Valve in the Pulling Position. 4

Prepared By gib1 02nd July 99


Rev 0000 Section 1 Page 2 of 3 Approved By adg1 02nd July 99
Linkage 3.1 Document DB625-2725-00-01 Page 3 of 16
PETROLINE WELLSYSTEMS LTD

INTRODUCTION TO THE STANDING VALVE

The prime criteria for the development of this tool was to


significantly reduce the number of wireline runs required
during the completion of a well.

The Retractable No-Go Standing Valve provides a high


pressure test capability with a single wireline run. The
standing valve can be used both in Petroline’s QN nipple
profiles and in other manufacturer’s profiles.

The valve features:

* 5,000 to 10,000 psi pressure ratings as standard.

* Single run to set and retrieve.

* Hydraulic set capability (no downward jarring required


for high deviation wells).

* Not reliant on operator ability.

* Flow through capability.

The Standing Valve is designed to be set in the nipple


profile by hydraulic means, and no downward jarring is
required. The tool is therefore ideal for high deviation
applications and has been successfully run in wells up to 79
degrees deviation.

The equalisation section can be provided with a spring &


ball retainer to ensure a positive seat of the sealing ball if
required.

Prepared By gib1 02nd July 99


Rev 0000 Section 1 Page 3 of 3 Approved By adg1 02nd July 99
Linkage 3.1 Document DB625-2725-00-01 Page 4 of 16
PETROLINE WELLSYSTEMS LTD

TECHNICAL INFORMATION FOR 2.725" RNQN STANDING VALVE

Assembly Number : 625-2725-00-01

Pressure Rating : 10,000 psi

Setting Pressure Maximum Allowable : 2,200 psi

Setting Pressure Nominal Value : 1,900 psi

Metallic Material : 17/4 P.H. Stainless Steel

Metallic Material (Coil Springs) : N/A

Elastomer Material : Viton

Chevron Material : Glass Filled Teflon

Coatings (Stainless Steel) : Q.P.Q Process

Minium Tensile Strength : 42,750 lbs @ Equ. Section.

Fishing Neck Size : 1.750"

Flow Area : 0.31 sq in.

Equalising Assembly : 218-2000-00-05

Prepared By gib1 02nd July 99


Rev 0000 Section 2 Page 1 of 2 Approved By adg1 02nd July 99
Linkage 3.1 Document DB625-2725-00-01 Page 5 of 16
PETROLINE WELLSYSTEMS LTD

TECHNICAL ILLUSTRATION FOR 2.725" RNQN STANDING VALVE


Assembly No : 625-2725-00-01

Prepared By gib1 02nd July 99


Rev 0000 Section 2 Page 2 of 2 Approved By adg1 02nd July 99
Linkage 3.1 Document DB625-2725-00-01 Page 6 of 16
PETROLINE WELLSYSTEMS LTD

ASSEMBLY ILLUSTRATION FOR RNQN STANDING VALVE


Assembly Drawing No : A625-9999-014

Prepared By gib1 02nd July 99


Rev 0000 Section 3 Page 1 of 6 Approved By adg1 02nd July 99
Linkage 3.1 Document DB625-2725-00-01 Page 7 of 16
PETROLINE WELLSYSTEMS LTD

PARTS LIST FOR 2.725" RNQN STANDING VALVE

Assembly No : 625-2725-00-01 Ref. Assy. Dwg. A625-9999-014

Item Description Qty Part No


001 2.000" Std. Valve Sub Assembly 1 218-2000-00-05
002 Plunger 1 625-2635-02-45
003 Main Body 1 625-2725-01-45
004 Lock Out Keys 4 625-2725-03-45
005 Finger Sleeve 1 625-2635-05-45
006 Lock Down Collet 1 625-2635-04-45
007 Packing Barrel 1 625-2725-02-45
008 Bottom Sub 1 625-2635-07-45
009* Grub Screw (1/4"-20UNC x 1/4") 2 GS-020
010a* Elastomer (O-Ring) 1 OV-123-075
010b* Elastomer (Parbak Ring) 2 PB-123-N90
011a* Elastomer (O-Ring) 1 OV-218-075
011b* Elastomer (Parbak Ring) 2 PB-218-N90
012a* Elastomer (O-Ring) 1 OV-122-075
012b* Elastomer (Parbak Ring) 2 PB-122-N90
013* Shear Screw (1/4"-20UNC) 4 SS-011
014* Shear Screw (5/16"-18UNC) 3 SS-010
015* Shear Screw (1/4"-20UNC) 4 SS-005
016* 2.725" Chevron Packings 3 243-2725-BI-01
017 Male End Adaptor 1 245-2725-02-45
018 Female End Adaptor 1 245-2725-01-45

* Redress Kit : 625-2725-90-01


in cluding : 218-2000-90-05

Prepared By gib1 02nd July 99


Rev 0006 Section 3 Page 2 of 6 Approved By adg1 02nd July 99
Linkage 3.1 Document DB625-2725-00-01 Page 8 of 16
PETROLINE WELLSYSTEMS LTD

ASSEMBLY INSTRUCTIONS FOR RNQN STANDING VALVE


Ref. Assy. Dwg. A625-9999-014
General Instructions
Ensure all parts are clean.
Apply copperslip to all threads.
Apply grease to all sealing surfaces.
Do not wrench on No-Go finger area.
Back off all shear screws by a quarter turn.
Fig :- 001
Assembly Instructions
- Install Elastomer/s (Items 10 and 11) into the Lock Down Collet (Item 06) then slide Lock Down
Collet into the Plunger (Item 02), secure by installing required number of Shear Screws (Item 15).

- With the box thread facing upwards, install the Lock Out Keys (Item 04) into the windows on the
Main Body (Item 03). NB: A small amount of grease on the Keys will help retain them in the
windows. Ensure Keys are fitted the correct way round with the 30 internal taper face matching
30 taper on the Plunger assembly. See Fig :-001.

- Place the Plunger Assembly (Plunger first) down into the Main Body and lift the Body until it
bottoms out on the inner assembly. The shear screw holes should be lined up with the track, then
install the required number of the Shear Screws (Item 14).

- Insert Elastomer (Item 12) into the Plunger. Make-up the Sub-Assy (Item 01) to the Plunger
utilising a screw driver through the equalising ports, and then secure with Grub Screw.

- Slide the Finger Sleeve (Item 05) down into the Main Body until the shear screw holes line up with
the groove. Install Shear Screws (Item 13).

- Install the Packing Stack (Items 18, 16 and 17) respectively, onto the Packing Barrel (Item 07).
Thread the Packing Barrel into the Main Body and secure with Grub Screw (Item 09).

- Thread the Bottom Sub (Item 08) onto the Packing Barrel and secure with Grub Screw (Item 09).

Disassembly Instruction
- Remove all Grub Screws.

- Remove Bottom Sub and using the lead in angle on the lower end push against the Packing Barrel
end face to hence collapse the internal fingers of the Lock Down Collet back inside the Body.

- The remainder of the tool should be disassembled opposite to the assembly instructions.

- All parts should be inspected for damage and replaced as necessary

Prepared By gib1 02nd July 99


Rev 0000 Section 3 Page 3 of 6 Approved By adg1 02nd July 99
Linkage 3.1 Document DB625-2725-00-01 Page 9 of 16
PETROLINE WELLSYSTEMS LTD

ASSEMBLY ILLUSTRATION FOR STANDING VALVE


SUB ASSEMBLY
Assembly Drawing No : A218-2000-005

Prepared By gib1 02nd July 99


Rev 0000 Section 3 Page 4 of 6 Approved By adg1 02nd July 99
Linkage 3.1 Document DB625-2725-00-01 Page 10 of 16
PETROLINE WELLSYSTEMS LTD

PARTS LIST FOR STANDING VALVE SUB ASSEMBLY

Assembly No : 218-2000-00-05 Ref. Assy. Dwg. A218-2000-005

Item Description Qty Part No


001 Top Sub 1 218-2000-06-45
002 Inner Mandrel 1 218-2000-13-45
003 Connector 1 218-2000-12-45
004 Shear Sleeve 1 218-2000-11-45
005 Ball Seat 1 218-2000-10-45
006a* Elastomer (O-Ring) 3 OV-125-090
006b* Elastomer (Parbak Ring) 6 PB-125-N90
007* Grub Screw (1/4"-20UNC x 1/4") 3 GS-020
008* Shear Screw 4 SS-005
009 1" Steel Ball 1 SB-002

* Redress Kit : 218-2000-90-05

Prepared By gib1 02nd July 99


Rev 0004 Section 3 Page 5 of 6 Approved By adg1 02nd July 99
Linkage 3.1 Document DB625-2725-00-01 Page 11 of 16
PETROLINE WELLSYSTEMS LTD

ASSEMBLY INSTRUCTIONS FOR STANDING VALVE


SUB ASSEMBLY
Ref. Assy. Dwg. A218-2000-005

General Instructions
Ensure all parts are clean.
Apply copperslip to all threads.
Apply grease to all sealing surfaces.
Back off all shear screws by a quarter turn.

Assembly Instructions
- Install Elastomer/s (Item 06) into the Connector (Item 03) and Shear Sleeve (Item 04)
respectively. Slide the Shear Sleeve onto the Inner Mandrel (Item 02).

- Thread the Inner Mandrel onto the Connector. NB. The notch on the Connector OD should be
covered when the Inner Sleeve is fully made up. If this notch is visible continue threading until
it disappears under the Shear Sleeve, secure with Grub Screw (Item 07).

- Slide the Shear Sleeve down over the Connector until it locates on the square shoulder, install
Shear Screw (Item 08)

- Install Elastomer/s (Item 06) into the Ball Seat (Item 05). Install Steel Ball (Item 09) into the
Top Sub (Item 01). Thread the Top Sub onto the Shear Sleeve. This will automatically locate the
Steel Ball & Ball Seat in the correct position. Install Grub Screw (Item 07).

- The Standing Valve Sub Assembly can now be made up to the Main Assembly.

Disassembly Instructions
- Remove all Grub Screws.

- Disassembly should be opposite to the assembly instructions.

- On disassembly inspect all parts for damage and replace as necessary.

Prepared By gib1 02nd July 99


adg1
Rev 0000 Section 3 Page 6 of 6 Approved By 02nd July 99
Linkage 3.1 Document DB625-2725-00-01 Page 12 of 16
PETROLINE WELLSYSTEMS LTD

RUNNING/PULLING PROCEDURES FOR PETROLINE


RETRACTABLE NO-GO STANDING VALVES

The Petroline Retractable No-Go Standing Valve is run using standard wireline methods and can be
set either mechanically or hydraulically.

When setting the Retractable No-Go Standing Valve mechanically, make-up the Standing Valve to
the appropriate JDC or SB type Pulling Tool complete with brass pin. Lower the assembly into the
well bore until the No-Go Fingers on the Standing Valve make contact with the No-Go on the
Nipple Profile.

Downward jarring will cause the Shear Screws to shear and in turn will move the Inner Mandrel
down locking out the Locking Dogs and remove the support from the Retractable No-Go Fingers.
Further downward jarring will cause the Shear Pin in the Pulling Tool to shear. The toolstring can
now be retrieved from the wellbore.

When retrieving the Retractable No-Go Standing Valve lower the toolstring complete with the
appropriate JDC or SB type Pulling Tool into the wellbore and latch the Retractable No-Go Standing
Valve (an upward pull on the wireline will confirm latching).

Upward jarring will cause the equalisation screws and Inner Mandrel screws to shear and the
Standing Valve can now be retrieved from the wellbore.

If pressure testing is required in one run without shearing thr setting tool we recommend that the
Standing Valve is set hydraulically as follows:

Lower the Standing Valve in the wellbore, this should be done at a relatively steady
speed and care should be taken when passing through restrictions or when opening
the Spang Jars to prevent premature equalisation.

Once the Nipple is encountered 1 or 2 light downward taps should be applied to ensure the seals
have entered the seal bore then pressure can be applied.

1. If you require to stay on the device slack off 10· of wire approximately and apply the
Nominal Shear Out value of the Valve. Monitor the pressure for a few minutes then increase
up to the required test level. When the Standing Valve sets a slight reduction in pressure will
be seen at surface. On completion of test, jar upwards to equalise and unlock the Standing
Valve which can then be retrieved to surface.

Cont/,

Prepared By gib1 14/02/95


Rev 0000 Section 4 Page 1 of 5 Approved By mcg1 14/02/95
Linkage 3.1 Document DB625-2725-00-01 Page 13 of 16
PETROLINE WELLSYSTEMS LTD

RUNNING/PULLING PROCEDURES FOR PETROLINE


RETRACTABLE NO-GO STANDING VALVES

2. If you require to leave the Standing Valve in the Nipple slack off 10· wire apply the Nominal
Shear Out value of the Valve. Monitor the pressure for a few minutes then commence to jar
downwards, if during jarring the Valve is accidentally equalised pressure will be lost.

Monitor at all times when setting and if pressure does drop attempt to apply again. If indications are
that the Valve has been equalised jar up to retrieve.

NB: If pressure is lost cease downward jarring immediately, this may be in time to
prevent release of the running tool and will save unneeded wireline runs to
retrieve and reinstall the Valve.

Prepared By gib1 14/02/95


Rev 0000 Section 4 Page 2 of 5 Approved By mcg1 14/02/95
Linkage 3.1 Document DB625-2725-00-01 Page 14 of 16
PETROLINE WELLSYSTEMS LTD

TECHNICAL ILLUSTRATION OF RNQN STANDING VALVE


Drawing No : T990-9999-003

Retractable No-Go
Standing Valve
Shown in the
Run Position.

Prepared By gib1 14/02/95


Rev 0000 Section 4 Page 3 of 5 Approved By mcg1 14/02/95
Linkage 3.1 Document DB625-2725-00-01 Page 15 of 16
PETROLINE WELLSYSTEMS LTD

TECHNICAL ILLUSTRATION OF RNQN STANDING VALVE


Drawing No : T990-9999-009

Retractable No-Go
Standing Valve
Shown in the
Set Position.

Prepared By gib1 14/02/95


Rev 0000 Section 4 Page 4 of 5 Approved By mcg1 14/02/95
Linkage 3.1 Document DB625-2725-00-01 Page 16 of 16
PETROLINE WELLSYSTEMS LTD

TECHNICAL ILLUSTRATION OF RNQN STANDING VALVE


Drawing No : T990-9999-004

Retractable No-Go
Standing Valve
Shown in the
Retrieval Position.

Prepared By gib1 14/02/95


Rev 0000 Section 4 Page 5 of 5 Approved By mcg1 14/02/95