You are on page 1of 4

A77 BATTERY CHARGER /

BATTERY ELIMINATOR

WHY LA MARCHE
>>> Industry Leader In Custom Design Solutions For Over 70 Years
>>> Flexibility of Choice: Technology, Performance, Size, Cost
>>> Complete DC Solutions for your Mission Critical Needs
>>> Ability to Blend the Latest Innovative Technology with
field Proven Reliability

>>> Made in USA


Smart Microprocessor

2015
INTERNATIONAL
BUILDING

C
CODE

IBC

Controlled SCR Technology


1012 SEISMIC CERTIFIED
2006 2009 2012

The La Marche Model A77 Series Battery Charger is


engineered for the demanding requirements of
User Friendly
Switchgear, Process Control, Oil Exploration and other
Interface DC power applications. Powered by Microprocessor
Controlled SCR technology, the A77 Series Battery
Charger / Battery Eliminator has ±0.25% DC voltage
Fault Tolerant regulation from no load to full load over the specified
input voltage, frequency and ambient temperature
ranges. These chargers are available in DC output
voltages of 12, 24, 48, 130*, and 260* VDC with DC
Self-Diagnostics and output currents from 6 amps and above.
System Protection * Can be used on 125V and 250V applications respectively

Secure Remote Monitoring COMPLIANCE


and Communications UL 1012 / CUL / CSA / CE
-----------------------------------
ABS
-----------------------------------
Digitally Configurable NEMA PE5
-----------------------------------
Parameters EMC: IEC 61000-4
-----------------------------------
Conducted Susceptibility:
IEEE / ANSI C37.90.1 / IEEE C62.41 /
Advanced Data Logging IEC 60001.4.5 / IEEE-472
-----------------------------------
Radiated & Conducted Emission:
CENELEC EN 55011 / EN55022 /
FCC Part 15B CFR 47 / ICES-003
NERC PRC-005 -----------------------------------
Seismic / IBC
-----------------------------------

La Marche Mfg (A U.S. Company) | 106 Bradrock Drive, Des Plaines, IL 60018 | Tel: 001.847.299.1188
sales@lamarchemfg.com | www.lamarchemfg.com
PROTECT THE DC SYSTEM AND BATTERY
MAINTAIN CLEAN AC
POWER LINES LOW THD
12 PULSE RECTIFICATION DIGITAL AC POWER MONITORING
A77 Chargers are offered in a 12 A77 Chargers monitor AC power lines in

12
12
Pulse SCR arrangement in order to
12
single phase and three phase installations
and report voltages and currents of all
pulse pulse
immensely reduce the Total

PULSE Harmonic Distortion to less than


10%.
phases individually. All readings
displayed on the digital LCD display,
are

reported through multiple communications


protocols and logged into the data logging file.

5% THDi AC GENERATOR OPERATION


Three Phase A77 Chargers can further A77 is immune to distortions in the

5% reduce the THDi to even less than 5%


on the AC power line with the input
generators output power and maintains a
steady DC power for the battery and loads.

THDi THD filter. A77 chargers are capable of LOAD SHARING


when powered by multiple generators and
power sources

PROTECT YOUR CHARGING SYSTEM!


DIGITAL GROUND CHARGER SELF
DETECTION DIAGNOSTICS
Constantly monitor any ground faults that may occur in Avoid systems faults! A77 detects and responds to
the DC system and receive an alarm. A77 Chargers internal operation faults, equipment and battery
provide the capability to disable or digitally adjust the overheat conditions, and charging system faults.
sensitivity of the ground detection system!
REVERSE POLARITY
SHORT CIRCUIT
PROTECTION A77 Battery charger is self-protected against reverse
polarity connection when supported with this feature.
A77 Battery Chargers are immune against short circuit
faults. The La Marche Battery Charger has the ability to
restore a completely discharged battery. BATTERY TEST
x

The A77 charger performs a periodic battery continuity


test on the battery in the DC system.
PROTECT YOUR BATTERY!
Protect the battery and Loads by shutting down the charger in case a high voltage exists
HIGH DC VOLTAGE
in the DC bus. A77 chargers are also capable of sending a signal to trip the AC feeder
PROTECTION
breaker in the system!

Protect your batteries from overcharging and overheating by automatically


DIGITAL adjusting the output of the charger according to the temperature of the battery. A77
TEMPERATURE Chargers provide the capability to specify the temperature adjustment rate based on the
COMPENSATION battery’s manufacturer data. A77 also detects if a battery temperature probe is
open/short and sends an alarm signal.

COMPLETELY A77 Chargers are capable of reconditioning completely discharged batteries. A77 brings
DISCHARGED BATTERY the battery voltage back to normal levels.

BATTERY ELECTROLYTE A77 Battery Charger can communicate with many commercial Battery Electrolyte
ALARMS sensors and provide an alarm in case of any faults detected by the sensor

A77 Battery Charger can communicate with many commercial Hydrogen sensors. in case
of detecting high levels of Hydrogen in the system
HYDROGEN DETECTION » A77 provides two levels of protection based on the level of hydrogen that’s detected;
ALARMS it either tapers down the output power to the battery or completely shut down the system
» Provides an Alarm
» Capable of turning ON a fan if applicable

AUTOMATIC MANUAL Help protecting your battery against sulfation by periodically equalizing the battery. A77
BATTERY EQUALIZATION Chargers are also capable of driving an Equalize condition ventilation fan.
MODES

MONITOR YOUR DC SYSTEM!

ADVANCED REMOTE ACCESS ALARM CONTACTS


DATA LOGGING A77 Chargers allow the user to Communicate system faults to your
This series is equipped with a unique remotely monitor the system and DC system controller through A77’s
time & event based data-log with a receive alarms and status notification dry alarm contacts
battery backup for real-time-clock of the condition of the system. The
» Control the operation of those
stamp, to a removable micro-SD advanced communications card
contacts between Latching or
card. This allows trending the health utilizes multiple communications
non-latching
of your DC system, and knowledge protocols such as DNP3.0, Modbus,
» Easily perform a periodic test on
of the history leading up to the IEC 61850 and SNMP while main-
the alarm contacts and verify their
event. taining a high level of security in
operation
accordance with NERC require-
ments.
DC SYSTEM MODULAR ENCLOSURE
Hydrogen Sensor

Load DC Center Water Level Sensor

HVAC
Battery Informer

A77 Battery
Battery/Load Breaker
Charger
Panels

Batteries

Modular Enclosure
(IP 65)

La Marche Modular Enclosures are designed to protect electrical and electronic equipment in a
MODULAR variety of different fields and applications. Each enclosure provides full protection from dirt, dust,
ENCLOSURES moisture, oil and other contaminants.

La Marche Stationary Battery Informer (BI) is a breakthrough in technology. This tester can be
installed in any battery system. The BI can determine the condition of your batteries under load
BATTERY without disrupting the system operation. The battery and charger are never disconnected from the
INFORMER load even during the test. The intelligent tester control circuit will not allow testing to take place while
the batteries are being used in an emergency situation or if they are recharging from a recent
discharge. It will also signal if the tester has failed and/or the charging system is inoperative.

La Marche LDC delivers the highest level of circuit protection and offers a robust and innovative
configuration that simplifies any installation. It is available for 24V, 48V and 130-Volt system with the
LOAD DC
option to include a main breaker. The LDC breakers are 2-pole, 250 VDC and minimum 10 kAIC
CENTER
rated. Loads are connected directly to the breaker, in order to establish a more secure and reliable
connection.

Incorporating thermal cooling with an enclosure can lengthen system life and increase the reliability
THERMAL
of the system. La Marche offers different solutions with fans, vents or HVAC to accommodate
MANAGEMENT different environments.

HYDROGEN Battery compartment can be equipped with a hydrogen sensor. Form C contacts will trigger at 1%
SENSOR and 2 % hydrogen concentrations and initiate a forced battery charger shutdown

BATTERY ELECTROLYTE The battery electrolyte level monitoring system saves money by continuously monitoring electrolyte
WATER SENSOR level and eliminating the need for scheduled periodic testing & maintenance.

BREAKER La Marche Disconnect Circuit Breaker Panel is designed to provide a quick and convenient method
PANELS to disconnect a battery, a load or a charger from the DC power system.

La Marche Relay Rack Mounted Battery Trays are beneficial if floor space is confined and batteries
BATTERY are to be mounted directly in the DC power system equipment racks. There are 19" or 23" rack
TRAYS configurations with 500lb capacity for 19" trays and 600lb capacity for 23" trays.