A 2382 I/S CASING


A
14065 RF TO HEATER CL 2232 I/S LINING
13815 RF TO HEATER CL
1 OFF 610x610 BOLTED 6134 6134
MAINTENANCE DOOR 3059
PER TRANSITION OUTLET J

2096 I/S CASING


1946 I/S LINING
DUCT 2100
O2A
AA
PT

300
B TT
B
150
BIH EL+19313
APH OUTLET CL 150
FGS
BIH EL+16388 TRANSITION EXIT DUCT
1896

300
J
T.O CONVECTION
SECTION AA-AA
BIH EL+15738
J AA SCALE 1 : 50
C PROCESS INLET
C
AA AA
1029

N1 ~ N8

BIH EL+14764
STEAM COIL
OUTLET R.F. N18

D D
3838

BIH EL+14458 13661 13962


STEAM COIL
INLET R.F. N17 1432 1432 BIH EL+13150
(TYP) (TYP) CROSSOVER OUT

BIH EL+12550
U/S CONVECTION
E
2500

D E

(TYP)
500

455
D
BIH EL+10050
U/S RADIANT
BB ARCH C BB
FGS N.S
TT N.S TT N.S TT N.S TT N.S TT N.S
BIH EL+9595
FGS F.S JUMPOVER OUT/
F TT F.S TT F.S TT F.S TT F.S TT F.S F
327 CLEAR 327 CLEAR CROSSOVER IN
(COLD) TOP OF TOP OF TOP OF TOP OF TOP OF (COLD)
DUCT DUCT DUCT DUCT DUCT
RADIANT PANEL
BIH EL+6292 TSTC PAD HORIZONTAL SPLICE 2
7612

B 400
PROCESS OUTLET (TYP LAST EXTERNAL
2 TUBES JUMPOVER
N9 , N11 , N13 & N15 OFF EACH

6656
PASS)

G BIH EL+5987 G
PROCESS OUTLET 400
N10 , N12 , N14 & N16 RADIANT PANEL
HORIZONTAL SPLICE 1
280

280
BIH EL+4012
RADIANT SIDE WALL
OBSERVATION DOORS CL
280
1574

BIH EL+2438 BIH EL+2939


1000

H U/S RADIANT H
JUMPOVER IN
FLOOR

501
A
762

BA BA
2438

BIH EL+1676 4 OFF N.S TSTC TOTAL 28 OFF (14 OFF PER
U/S BASE PLT RADIANT) FORCED DRAFT
1676

LOW Nox COMBINATION


4 OFF OPP.S TSTC FIRED BURNERS AND 2 OFF
BIH EL+0 GAS & SOUR GAS BURNERS
J CLIENT EL+26700 J
GRADE
570 1671 1448 400 1694 1471 924 747 1671 1271 400 1671 1671 747 924 1471 1694 400 1448 1671 570 1396

4089 4089 4089 4089 4089 4089


896 TO 896 TO
O/S CASING 24534 O/S CASING
26326

14470 RF TO HEATER CL 15 OFF SIDE WALL


VERTICAL

OBSERVATION DOOR
RADIANT

K 14730 RF TO HEATER CL K
AT N.S RADIANT
SPLICE
PANEL

(SOUTH FACE)
15 OFF AT F.S RADIANT
(NORTH FACE)

B.I.H
AS PER 709-BIHS-280
1 2 3 4 5 6 7
HEATER
CL
NOTES BOUSTEAD INTERNATIONAL HEATERS Ltd.
L DRAWING TITLE
1. BIH EL+ 0.00 EQUIVALENT TO CLIENT GRADE EL+ 26700.00. L
2. ALL DIMENSIONS SHALL BE VERIFIED AND ANY GENERAL ARRANGEMENT
PIPE RACK REMOVED FOR CLARITY 3.
DISCREPANCIES SHALL BE REFERRED TO BIH FOR RESOLUTION.
ALL DIMENSIONS IN MILLIMETRES UNLESS OTHERWISE STATED. SHEET 1 OF 5
4. REFER 09 SERIES DRAWINGS FOR LADDERS AND PLATFORMS SERVICE
CRUDE HEATER 1F-1
ELEVATION VIEW ON A / 1-7 5.
GENERAL ARRANGEMENTS.
THIS DRAWING SHOULD BE READ IN CONJUNCTION WITH FOR
VIEW ON SOUTH FACE LOOKING NORTH DRAWING(S):
• 709-02B,C,D & E
• 709-03A DRAWN DATE CHECKED DATE APPROVED DATE
• 709-09A LWC 10.12.15 RJS 17.12.15 PSB 29.01.16
M PROCESS DESIGN DATE STRUCTURAL DESIGN DATE
FILENAME: K:\CAD\709 SYNERGY\GA\709-02A & 2B SHEET SCALE: 1:60 ORIGINAL SIZE: A1 DO NOT SCALE NOTE: THIS DRAWING IS THE PROPERTY OF BOUSTEAD REVIEW REVIEW M
REV. 3 BY DATE CHECKED DATE DESIGN REVIEW DATE APPROVED DATE REV. 2 BY DATE CHECKED DATE DESIGN REVIEW DATE APPROVED DATE REV. 1 BY DATE CHECKED DATE DESIGN REVIEW DATE APPROVED DATE INTERNATIONAL HEATERS LTD. BURGESS HILL, SUSSEX, U.K. AND (IF APPLICABLE) (IF APPLICABLE)
- - - - - - - - - - - - - - - - - - - - - - - - SHALL NOT BE TRACED, PHOTOGRAPHED, PHOTOSTATED OR IH 17.12.15 MDS 01.02.16
REPRODUCED IN ANY MANNER NOR USED FOR ANY PURPOSE
- - - WHATSOEVER EXCEPT BY WRITTEN PERMISSION OF BOUSTEAD JOB DRAWING REV
INTERNATIONAL HEATERS LTD. NUMBER 709 NO. 709-02A 0