You are on page 1of 8

Sysmex

UN-3000

Three Seperate Analyzers:


• UC-3500 (Chemistry)
• UF-5000 (Sediment)
Analyzer Combination • UD-10 (Digital Imaging)
Specimen Type: Urine and Body Fluid
Body Fluid Analysis Capable
UC-3500:
Test Strips in Bottle
- UC-Meditape 9A
- UC-Meditape 11 A
Saline

UD-10:
- UF-Cellsheath
- CellClean

Consumables

UF-5000:
- UF-Cellpack CR
- UF-Fluorocell CR
- UF-Cellpack SF
- UF-Fluorocell SF
- UF-Cellsheath
- Distilled Water
UC-3500:
100 Test Strips / Bottle
(Max of 3 Bottles On-board or 300 Strips)

Packaging
UF-5000:
- UF-Cellpack CR: 2L
- UF-Fluorocell CR: Cartridge
- UF-Cellpack SF: 2L
- UF-Fluorocell SF: Cartridge
- UF-Cellsheath
Liquid Reagents Yes
UTI Detection Yes

UF: Fluorescence Flow Cytometry with Blue


Semiconductor Laser
UC: Reflective Photometry -
Imaging and Image process by color CMOS
sensor
Measurement Technology UD: Dual Flow cell digital imaging

UF-5000: 105 samples/hour


UC-3500: 276 samples/hour
Throughput UD-10: 50 samples/hour
Storage 100,000 (with U-WAM)
STAT Function Yes
Cross-Check Function Yes

• cells/uL
Sediment Result Units • cells/hpf
• cells/lpf

• Conventional
Chemistry Result Units • Conventional with plus system
• SI
• SI with plus system
With Quantitative count for Bacteria
Time to First Result <1minute
Sample Loading Capacity 80 Samples

UF: 2ml
Minimum Sample in Tube UC: 1ml
UD: 1.6ml

Sysmex
UC-3500 /UD-10
Description UC: Urine Chemistry Analyzer
UD: Urine Digital Imaging Analyzer
UD: LED Source (Pulse emission) and CCD
Camera
Digital Camera Module

Measurement Principles Specific Gravity: Trasmission Refractometry


Color and Turbidity: Colorimetry
Optical Sensors:
Color CMOS Sensor
Throughput 276 Sample/Hour
Display Colored Touch Screen LCD
Max Sample Capacity 80 Samples
Calibrator Requires Reconstitution
Internal Calibration on each sample
Cassette Type Test-Strip Pads (Bottle Format)
Test-Strip Pads Packaging 100 Test-Strip Pads/ Bottle
UC-Meditape 9A
Test Menu Option UC-Meditape 11A
UC-Meditape 9A
Bilirubin
Glucose
Ketone
Leucocyte Esterase
Nitrite
Occult Blood (RBC / Hemoglobin)
pH
Protein
Urobilinogen

Strip Parameters

UC-Meditape 11A
Same as 9A
Albumin
Creatinine

Auto-Calculation Albumin-to-Creatinine Ratio


Protein-to-Creatinine Ratio

Color
Analyzer Parameter Turbidity
Specific Gravity

Sysmex
UF-5000
Specimen Type: Urine and Body Fluid
Body Fluid Analysis Capable

UF-5000:
- UF-Cellpack CR
Consumable - UF-Fluorocell CR
- UF-Cellpack SF
- UF-Fluorocell SF
- UF-Cellsheath
- Distilled Water
• RBC (red blood cell)
– Non-lysed RBC
• WBC (white blood cell)
– WBCc (white blood cell clump)
Sediment Parameters • BAC (bacteria)
• EPI (squamous epithelial cell)
• NEC (nonsquamous epithelial cell)
– Renal Tubular EC
– Transitional EC
• Hyaline Cast
• Pathological Cast
• Crystals
• Yeast-Like Cells (YLC)
• Mucus
•Sperm Cells

• RBC (red blood cell)


• WBC (white blood cell)
Body Fluid Parameters
• MN
• PMN
• TNC
• Bact
UTI Information Yes (with quantitative measurement of
bacterial count)
RBC Morphology Information Yes
Bacterial Gram Staining
Classification Yes
Siemens
Atellica 1500
Two Separate analyzers:
• CLINITEK Novus (Chemistry and Digital Imaging)
• Atellica UAS 800 (Sediment)

Urine Only
No
CLINITEK Novus:
Test Strips in Cassette
- Clinitek Novus 10 Cassette
- Clinitek Novus Pro Cassette

Attelica UAS 800:


- Cuvettes Only (Cartridge Type)

CLINITEK Novus:
450 Test Strips / Cartridge

Attelica UAS 800:


Cuvettes: 600 Cuvettes / Cartridge

None
Yes
Digital microscopy imaging with dual-focusing
mechanism to generate clear image

240 samples/hour

10,000 patient results including images


Yes
?

• cells/uL
• cells/hpf
• cells/lpf
• Conventional
• Conventional with plus system
• SI
• SI with plus system

< 4minutes
100 Samples

2.6mL

Siemens
CLINITEK Novus

Urine Chemistry and Digital Imaging Analyzer

LED and Colored CCD Camera that captures full


RGB Color spectrum to calculate color changes for
each parameters, instead of a 3-4 wavelengths
Specific Gravity and Clarity: Refractometry

Refractometry Method:
Calculates Clarity and Specific Gravity
240 Samples/Hour
Tiltable Colored Touch Screen
200 Samples (Clinitek Alone)
Ready-to-Use
True-Analyte Calibration / "Live Calibration"
Test-Strip Pads (Cassette Format)
450 Test Strip Pads/ Cassette
Clinitek Novus 10 Cassette
Clinitek Novus Pro 12 Cassette
Clinitek Novus 10 Cassette:
Bilirubin
Glucose
Ketone
Leucocyte Esterase
Nitrite • UC can differentiate Hemoglobin from RBC
Occult Blood • With Abnormal Discoloration Flagging
pH • Novus has "10" but Color is not clarified whether part
Protein of the strip or same as UC which is an analyzer
Urobilinogen parameter. Regardless if 9 or 10, both measure the same
Color number of parameters except that UC can differentiate
Clarity Hemoglobin from RBC. Not stated on Novus whether it
Specific Gravity can or not.
Clinitek Novus Pro 12 Cassette:
Same as Novus 10
Albumin
Creatinine

Albumin-to-Creatinine Ratio
Protein-to-Creatinine Ratio

Color*
Clarity
Specific Gravity

Siemens
Atellica AUS 800
Urine Only
No
Cuvettes Only
EC differentiation takes much information about
Associated Diseases and Clinical Departments. (Ex. RTEC
- Glomerulonephritis; Trans EC - Cystitis

• RBC (red blood cell)


• WBC (white blood cell)
– WBCc (white blood cell clump)
• BAC (bacteria)
– BACr (rod bacteria)
– BACc (coccus bacteria)
• EPI (squamous epithelial cell)
• NEC (nonsquamous epithelial cell)
• HYA (hyaline cast)
• PAT (pathological cast)
• CRY (crystal)
• YEA (yeast)
• MUC (mucus)
• SPRM (sperm)

None
Yes