Checked by:
Date:
TSC Replacement MTS2 /MTS4
Description
TSC replacement
Disconnect the PSU Input power
Wear an antistatic wrist strap.
Take a note and disconnect all cables connected to the TSC.
Unscrew the TSC bottom and top screws.
Gently slide the TSC module and disconnect the ribbon cables connected at the back of the module.
Install the new module after connecting the back ribbon cable.
Screw the top and bottom screws to secure the module in place.
Connect all the front cables including the Power supply cable.
Start you terminal Emulator application on your Laptop.( Procomm Plus version 4.8)
Once the TSC has finished the boot sequence , connect your laptop to the TSC , log in , and type attrib
command to check
TSC Application: the40
R07 dw23versions.
BRC Application: R07 00 08
Take a note of these versions
NOTE: if these versions are wrong, follow the software download SDWL update for TSC -BR ,if not
continue.
E1 slots update
Reset the TSC by entering the command SC>reset
connect with Procomm Login: your name Password:factory
Type .e1config -siteLink dual ( don't forget the dot)
To the question Are you sure you want to continue ? Answer y
Type .e1config -DI off
To the question Are you sure you want to continue ? Answer y
Type .e1config -channel 1 -portNo 1 -tsPattern x x(MTS2) ou x x x (MTS4) (x x x ou xx are the E1
slots : example 13 14 for MTS2 or 1 2 3 for MTS4
To the question Are you sure you want to continue ? Answer y
Type .e1config -channel 1 -portNo 2 -tsPattern x x(MTS2) ou x x x (MTS4) (x x x or xx are the E1
slots)
Reset the TSC by entering the command SC:reset
Loading the config with the TESS application software.
To upload the configs from your PC launch the TESS application ver R07.02.01
WARNING :Make sure that Bank 1 is active for TSC and BR.
Remove the unwanted components with the command sc>can remove_mapping (exemple) PSU 2
JTGN050010
Check again the CAN config by using the command SC>can view_mapping_list
reset sc> then login with the factory password.
Check for the presence of Fans at the bottom of the MTS2 ou MTS4 racks.
Type the command PSU 1 set fan_config X X X ( 1 or 0 depending of the presence or not of fans)
Check config
verification IP
VSWR alarm
VSWR max alarm
Verification alim
PSU status
DPM status
WAT = Wide Area Trunking
BR replacement 0n MTS2/MTS4
Task No: Description
1 If possible remove power from the MTS 2 or 4 by switching off the Power
Supply Unit,To perform a hot swap of a Base Radio, do not turn off the
Power Supply. Connect a terminal to the Service Port and log in. Make
sure the Base Radio is not transmitting
by entering the MMI command:dekey
2 Unplug the cables at front of the Base Radio that you replace.
3 Remove the TORX screws securing the faulty module to the chassis;
these are located on the top and bottom of the front plate of the faulty
module. Save the screws for reuse.
4 Pull out the module
5 Insert the replacement Base Radio by aligning the side rails with the
appropriate rail guides inside the Base Radio chassis
6 Gently push the replacement module completely into the Base Radio
chassis assembly using the module handle(s).
7 Secure the replacement module using two TORX screws removed during
module removal.Tighten the screws to a torque of 2.7 Nm.
8 Reconnect the cables to the BR front plate.
9 Switch on the Power Supply Unit (You do not need do this if doing a
hotswap).
10 Setting and Accessing Base Radio Position Using Test Application
11 Connect your laptop to the BR
12 Connect to the BR with your name and the password motorola
13 Type reset at the BR login
14 Press escape to be in boot1 mode
15 Type tessapp to enter test app ode
16 Login with login -ufactory password : factory
17 In order to configure BR cabinet id in the Test Application, use the
following command at the command prompt: Radio.
18 Type : ci -oplatform -c<n>
19 where <n> is a number between 1 and 8 corresponding to the cabinet id
of the Base Radio.
20 In order to configure BR position id in the Test Application, use the
following command at the command
prompt:
21 Type pi -oplatform -p<n>
22 where <n> is a number between 1 and 8 corresponding to the position id
of the Base Radio.
23 Type the command reset -oplatform and wait for the BR reboot.
24 Check for the BR status from Zone watch and by making a few talkgroups
calls.
25 Base Radio Receiver Configuration in application mode
26 Connect your laptop to the BR
27 Connect to the BR with your name and the password motorola
28 Type get nvm_param rx1 atten_default and press Enter.
29 Type get nvm_param pa dekey_limit and press Enter.
30 Type get nvm_pram rx1 rx_dc_inj_usl and press Enter.
31 Login with login -ufactory password : factory
32 Type get nvm_pram rx1 rx_dc_inj_lsl and press Enter
33 Type get nvm_pram rx1 ad1_scaling6 and press Enter.
34 Type get nvm_pram rx1 rx_fru_config and press Enter.
35 One receiver antenna on RF 1
36 One receiver antenna on RF 2
37 Two receivers on RF Port 1 & 2
38 One receiver antenna on RF 3
39 Two receivers on RF Port 1 & 3
40 Two receivers on RF Port 2 & 3
42 Log out rom the BR and check the status from Zone watch and by making
a few talkgroups calls.
Checked by:
Date:
Alain Guédès 14 May 2011 ver 1.4
Complete
Note: You can procede to a BR replacement by switching off the BR
or by hot swapping method.