TILING 09 30 00

®
Custom Building Products

1. Product Name
LevelQuikª RS Rapid Setting Self-Leveling
Underlayment

2. Manufacturer
Custom Building Products
13001 Seal Beach Blvd.
Seal Beach, CA 90740-2757
(800) 272-8786
(562) 598-8808
Fax: (800) 200-7765
E-mail: contactus@cpbmail.net
www.custombuildingproducts.com

3. Product Description
BASIC USE
• Laminated flooring surfaces that require drainage
LevelQuikª RS helps level interior and exterior
COMPOSITION & MATERIALS • This product is not meant for use as a wear
floors prior to the installation of ceramic tile,
surface
natural stone, resilient flooring, carpet, wood LevelQuik is a dry, proprietary blend of
and other floor coverings. This quick setting copolymers, portland cement and inorganic
4. Technical Data
underlayment can be applied to 1" (2.54 cm) materials.
ASTM International (ASTM)
thick in one pour and seeks its own level in
SIZES • ASTM C627 Standard Test Method for
minutes. With proper installation, the use of
LevelQuik RS underlayment is offered in 50 lb Evaluating Ceramic Floor Tile Installation
LevelQuik RS can achieve an extra heavy rat-
(22.68 kg) bags. Systems Using the Robinson-Type Floor
ing for high impact use in food plants, dairies,
BENEFITS Tester
breweries and kitchens. Formulated using
• ASTM F1869 Standard Test Method for
Controlled Cure Technology«, LevelQuik RS • Can be applied from featheredge to 1" (2.5
Measuring Moisture Vapor Emission Rate of
helps eliminate installation problems such as cm) thick in a single pour
Concrete Subfloor Using Anhydrous
bond failure, crumbling, mildew and staining • Reduces bond failure, mildew and crum-
Calcium Chloride
of resilient flooring caused by the free mois- bling of resilient flooring
ture found in traditional underlayments. • Cures fast and develops high early strength American National Standards Institute (ANSI) -
for quick installation ANSI A108/A118 American National Standards
Substrates for LevelQuik RS include:
• Rated for extra heavy use on wood sub- for the Installation of Ceramic Tile
• Concrete
• Cement backer boards floors with joists to 24" (61 cm) per ASTM Resilient Floor Covering Institute (RFCI) -
• WonderBoardª C627 Recommended Work Practices for Removal
• Exterior grade plywood (interior) with joists • Protected by MoldGardª Technology to of Resilient Floor Coverings
to 24" (61 cm) o.c. resist mold and mildew growth
Tile Council of North America (TCNA) - TCA
• Existing ceramic tile, pavers, brick LIMITATIONS Handbook for Ceramic Tile Installation, TCA
• Stone • Do not use over lightweight concrete, gyp- Method EJ171
• Concrete terrazzo sum underlayment. For special preparation
• Well bonded sheet vinyl TECHNICAL PROPERTIES
of these surfaces, RedGardª Waterproofing
• Cutback adhesive (non-water soluble) and Anti-Fracture Membrane is required. See Table 1.
Flooring types include: See Section 5, Lightweight & Gypsum
Cement Underlayment 5. Installation
• Ceramic tile, pavers, brick
• Stone, terrazzo • Do not use over oriented strand board PREPARATORY WORK
• Carpet (OSB), particle board, hardwood floors, par- General Surface Preparation
• Wood, parquet quet floors or metal Surfaces must be structurally sound, clean, dry
• Vinyl composition tile (VCT) • Do not use when the temperature is below and free from grease, oil, dirt and other cont-
• Sheet vinyl flooring 50 degree F (10 degrees C) or on sloped aminants that would prevent a good bond.

SPEC-DATA ª and MANU-SPEC ª are registered trademarks of Reed Elsevier Inc. The ten part SPEC-DATA format conforms to the editorial style
of The Construction Specifications Institute and is used with their permission. The manufacturer is responsible for technical accuracy. ©2008 Reed Construction Dataª. All Rights Reserved.
TILING 09 30 00

®
Custom Building Products

Ambient temperature, surfaces and materials TABLE 1 TECHNICAL PROPERTIES


should be maintained at temperatures higher
than 50 degrees F (10 degrees C). Property Results
Moisture vapor transmission should be less Flow time 10 minutes
than 4 lb (1.8 kg) per 1000 ft2 (92.9 m2) per day
Pot life @ 70 degrees F (21 degrees C) 30 minutes
in accordance with ASTM F1869 or equivalent.
If vapor transmission exceeds the recom- ASTM C191
mended maximum, contact Custom Building Initial set@ 70 degrees F (21 degrees C) 90 minutes
Products Technical Services for further assis- ASTM C191
tance. Final set@ 70 degrees F (21 degrees C) 3 1/2 hours
Cementitious Surfaces Walkable hardness after final set 2 - 4 hours
Concrete or plaster surfaces must be fully Drying time before covering installation
cured and must accept water penetration. Ceramic tile and stone 4 hours
Test by sprinkling water on various areas of Impervious floor coverings 14 hours
the substrate. If water penetrates, then a
ASTM C109
good bond can be achieved; if water beads, Compressive strength
surface contaminants are present, and loss of 1 day cure 2400 psi (1.65 MPa)
adhesion may occur. Contaminants should be 28 day cure 4400 psi (3.03 MPa)
mechanically removed before installation.
ASTM C109
Concrete must be free of efflorescence and
Flexural strength
not subject to hydrostatic pressure. Concrete 28 day cure 1100 psi (7.58 MPa)
slabs should have a broomed or brushed fin-
ASTM C627
ish to enhance the bond. Smooth concrete
Robinson-type floor test Extra heavy rating
slabs must be roughened to ensure a good
bond.
is normally less than 1 hour. Extremely porous adhesive residue, as harmful dust may result.
Lightweight, Gypsum based Underlayments surfaces may require 2 coats. Never use adhesive removers or solvents, as
Lightweight or gypsum based underlayments At this point, RedGard can be applied to they soften the adhesive and may cause it to
must first be treated with RedGard the primed lightweight or gypsum based sur- penetrate into the concrete. Adhesive
Waterproofing & Anti-Fracture Membrane face. Refer to the individual product data residue must be wet scraped to the finished
and must obtain a minimum of 2000 psi (1.37 sheet or packaging directions for application surface of the concrete, leaving only the
MPa) compressive strength at the manufac- instructions. Expansion joints must be installed transparent staining from the glue. To deter-
turer's recommended cure time. in accordance with local building codes and mine desirable results, do a test bond area
The underlayment must be sufficiently dry ANSI/TCNA guidelines. See TCNA EJ171 for before starting. For further details, refer to the
and properly cured to the manufacturer's detailed specifications. RFCI Pamphlet, Recommended Work
specifications for permanent, non-moisture Practices for Removal of Resilient Floor
Plywood Substrates
permeable coverings. Coverings.
Plywood floors, including those under resilient
Surfaces to be tiled must be structurally
flooring, must be structurally sound and must Priming
sound and subject to deflection not to
meet all ANSI and deflection requirements. Prime all surfaces with LevelQuik Latex Primer
exceed the current ANSI standards. Surfaces
For questions about proper subfloor installa- before application.
must be dry and free of all grease, oil, dirt,
tion, call Custom Building Products. METHODS
dust curing compounds, waxes, sealers, efflo-
For a metal lath, fasten every 6" - 8" (15 - 20
rescence, old adhesive residue and other Mixing
cm) with fasteners that have a galvanized or
compounds that may prevent a good bond. Mix the entire 50 lb (22.68 kg) bag of powder
corrosion resistant coating. For a 23/32" (18.2
All lightweight concrete and gypsum based with 6 1/2 quarts (6.1 L) of clean, cool water.
mm) plywood subfloor with 24" (61 cm) o.c.
underlayment surfaces to receive RedGard Slowly add powder to the water while mixing
joists, the metal lath must be a minimum of 2.5
must be primed with properly applied manu- with a heavy duty 1/2" (13 mm) electric drill
lb/yd2 (1.13 kg/m2). All plywood seams should
facturer's sealer or with a primer coat of and mixing paddle at 500 RPM. Thoroughly
RedGard, consisting of 1 part RedGard diluted be gapped 1/8" (3 mm) and protected by mix for 2 minutes to a lump-free consistency.
with 4 parts clean, cool water. Mix in a clean placing a minimum 1.5" (38 mm) bond break-
er tape over the gaps. Application
pail at low speed until a lump free solution is Apply LevelQuik Primer with a paintbrush, short
obtained. The primer can be brushed, rolled Cutback Adhesive over Concrete nap roller or soft push broom. Apply a thin
or sprayed to achieve an even coat. Apply Adhesive layers must be removed, as they even coat and allow to dry approximately 2
primer coat to the floor at a rate of 300 ft2 reduce mortar bond strength to cement sur- hours to a clear film. Pour or pump, and then
(27.9 m2) per gallon of reduced material. faces. Use extreme caution, as adhesives may spread with a long-handled gauged spreader.
Drying time will depend on site conditions, but contain asbestos fibers. Do not sand or grind LevelQuik RS will seek its own level during the

SPEC-DATA ª and MANU-SPEC ª are registered trademarks of Reed Elsevier Inc. The ten part SPEC-DATA format conforms to the editorial style
of The Construction Specifications Institute and is used with their permission. The manufacturer is responsible for technical accuracy. ©2008 Reed Construction Dataª. All Rights Reserved.
TILING 09 30 00

®
Custom Building Products

first 10 minutes. For featheredging and touch 8. Maintenance


up, use a smoothing tool. LevelQuik RS can be Properly installed product requires no special
applied to 1" (2.5 cm) thick in one application; maintenance.
if a second layer is required, install immediate-
ly after the first layer has set to a walkable 9. Technical Services
hardness. If the first layer has dried over 12 For technical assistance, contact Custom
hours, reprime before the second application. Building Products or visit the website:
For installation on wood subfloors with joists to www.custombuildingproducts.com.
24" (61 cm) o.c., apply a 1/2" (13 mm) thick layer
of LevelQuik RS over 3/4" (19 mm) exterior 10. Filing Systems
grade plywood with a with a minimum of 2.5# • Reed First Sourceª
properly fastened metal lath. • MANU-SPECª
Curing • Additional product information is available
LevelQuik RS dries to a walkable hardness in 2 from the manufacturer upon request.
- 4 hours. For ceramic tile and stone, allow 4
hours; for impervious floor coverings, allow 14
hours. Drying times can vary with temperature
and humidity. Test for moisture content before
applying vinyl or wood flooring.
Coverage
LevelQuik RS covers 50 ft2 per 50 lbs (4.65
M2/22.68 kg) at a 1/8" (3 mm) thickness.
Cleaning
Clean with water before the material dries.
PRECAUTIONS
This product contains Portland cement and
free silica. Wear rubber gloves and eye pro-
tection. Avoid eye contact or prolonged con-
tact with skin and wash thoroughly after han-
dling. If eye contact occurs, flush with water
for 15 minutes and consult a physician.
BUILDING CODES
Installation must comply with the requirements
of all applicable local, state and federal code
jurisdictions.

6. Availability & Cost


Contact the manufacturer or visit the
www.custombuildingproducts.com website
for information about product cost and avail-
ability.

7. Warranty
Warranties cover all interior and exterior resi-
dential and commercial installation systems.
System must be installed to industry and
Custom Building Products published specifica-
tions and use the full system of specified prod-
ucts. Surface preparation material selection is
optional depending on project requirements.
This warranty is not transferable.
For details and complete warranty informa-
tion, visit the Custom Building Products web-
site: www.custombuildingproducts.com.

SPEC-DATA ª and MANU-SPEC ª are registered trademarks of Reed Elsevier Inc. The ten part SPEC-DATA format conforms to the editorial style
of The Construction Specifications Institute and is used with their permission. The manufacturer is responsible for technical accuracy. ©2008 Reed Construction Dataª. All Rights Reserved.

You might also like