SPECIFICATION & RATE - 2010

PART I
SH: LAYING OF CONDUIT & FIXING ACCESSORIES
BEFORE CONCRETING
Sl. No Qty Specification Unit Rate
100 Supply and laying medium gauge PVC conduit conforming to IS
9537/1983 Part III n roof slab, jointing the pipes with PVC
solvent cement, tying & fixing the conduit firmly with the re-
inforcement etc. as required.

a 20 mm m 34.00
b 25 mm m 42.00
c 32 mm m 62.00
d 40 mm m 96.00
101 Supply and laying heavy gauge PVC conduit conforming to IS
9537/1983 Part III in roof slab, jointing the pipes with PVC
solvent cement, tying & fixing the conduit firmly with the re-
inforcement etc. as required.

a 20 mm m 41.00
b 25 mm m 51.00
c 32 mm m 75.00
d 40 mm m 106.00
102 Supply and fixing the following normal size PVC accessories
conforming to IS 3419/1988 along with the PVC conduits laid in
concrete
a1 20 mm one way terminal junction box E 31.00
a2 20 mm two way through junction box E 32.00
a3 20 mm two way angle junction box E 32.00
a4 20 mm three way tee junction box E 34.00
a5 20 mm four way intersection junction box E 36.00
a6 20 mm two way branch - U junction box E 42.00
a7 20 mm two way branch - Y junction box E 43.00
a8 20 mm two way branch - H junction box E 45.00

b1 25 mm one way terminal junction box E 35.00


b2 25 mm two way through junction box E 36.00
b3 25 mm two way angle junction box E 36.00
b4 25 mm three way tee junction box E 39.00
b5 25 mm four way intersection junction box E 41.00
103 Supply and fixing the following deep PVC accessories
conforming to IS 3419/1988 along with the PVC conduits laid in
concrete
a1 20 mm one way terminal junction box E 41.00
a2 20 mm two way through junction box E 42.00
a3 20 mm two way angle junction box E 42.00
a4 20 mm three way tee junction box E 43.00
a5 20 mm four way intersection junction box E 45.00

b1 25 mm one way terminal junction box E 45.00


b2 25 mm two way through junction box E 47.00
b3 25 mm two way angle junction box E 47.00
b4 25 mm three way tee junction box E 49.00
b5 25 mm four way intersection junction box E 52.00

c1 32 mm one way terminal junction box E 46.00


c2 32 mm two way through junction box E 49.00
c3 32 mm two way angle junction box E 49.00
c4 32 mm three way tee junction box E 52.00
c5 32 mm four way intersection junction box E 56.00

d1 Rigid PVC fan box with 20/25 mm KO E 50.00


d2 MS rod type fan clamp E 52.00
d3 MS fan box with fan clamp E 70.00
104 Supply and laying 16 SWG MS conduit conforming to relevant IS
specifications in roof slab, tying & fixing the conduit firmly with
the re-inforcement etc. as required.
a 20 mm m 71.00
b 25 mm m 92.00
c 32 mm m 99.00
105 Supply and fixing the following normal size MS accessories
conforming to relevant ISS along with the MS conduits laid in
concrete
a 20 mm junction box - 1/2 way E 28.00
106 Supply and fixing the following sizes of MS box made out of 1.60
mm MS sheet painted with 2 coats of enamel paint over a coat of
red oxide primer (without front cover) en-route the conduit as
junction boxes

a 75 x 75 x 50 mm E 70.00
b 100 x 100 x 50 mm E 81.00
c 100 x 125 x 50 mm E 92.00
d 125 x 150 x 50 mm E 102.00
e 125 x 200 x 50 mm E 121.00
f 125 x 250 x 50 mm E 141.00
g 125 x 300 x 50 mm E 162.00
h 150 x 150 x 50 mm E 127.00
i 150 x 200 x 50 mm E 152.00
j 200 x 250 x 50 mm E 215.00
k 200 x 300 x 50 mm E 245.00
l 250 x 300 x 50 mm E 286.00
m 250 x 375 x 50 mm E 336.00
n 250 x 500 x 50 mm E 427.00
107 Supply and fixing the following sizes of modular type recess
mounting metal box (group - A, without cover) en-route the
conduit as junction boxes
a 1 / 2 module E 43.00
b 3 module E 49.00
c 4 module E 58.00
d 5 module E 62.00
e 6 module E 81.00
f 8 module E 104.00
g 10 module E 109.00
h 12 module E 129.00
l 18 module E 157.00

108 Supply and fixing the following sizes of modular type recess
mounting metal box (group - B, without cover) en-route the
conduit as junction boxes
a 1 / 2 module E 49.00
b 3 module E 54.00
c 4 module E 63.00
d 5 module E 63.00
e 6 module E 91.00
f 8 module E 110.00
g 10 module E 116.00
h 12 module E 162.00
l 18 module E 183.00
109 Supply and fixing the following sizes of phenolic laminated sheet
as front cover to the existing MS boxes.
a 75 x 75 x 3 mm round / square E 18.00
b 100 x 100 x 3 mm E 21.00
c 100 x 125 x 3 mm E 22.00
d 125 x 150 x 3 mm E 29.00
e 125 x 200 x 3 mm E 32.00
f 125 x 250 x 3 mm E 36.00
g 125 x 300 x 3 mm E 39.00
h 150 x 150 x 3 mm E 28.00
i 150 x 200 x 3 mm E 35.00
j 200 x 250 x 3 mm E 46.00
k 200 x 300 x 3 mm E 55.00
l 250 x 300 x 3 mm E 64.00
m 250 x 375 x 6 mm E 136.00
n 250 x 500 x 6 mm E 177.00
110 Supply and drawing the following sizes of GI guide wire in the
existing conduit
a 18 SWG m 1.30
b 16 SWG m 2.00
c 14 SWG m 2.70
d 12 SWG m 4.70

PART II
WIRING POINTS
Wiring points with PVC conduit, MS box & piano type
120 accessories
Supply and wiring points according to IS 732-1989 using rigid
PVC conduit of minimum size 20 mm conforming to IS 9537 part
III 1983 and with suitable size specials conforming to IS 3419-
1988, fixing the conduit using metal saddles spacing not
exceeding 50 cm or concealed suitably and with 1.00 sq mm FR
PVC insulated stranded single core copper conductor cable 650V
grade, and continuous earthing with 1.5 Sq.mm green coloured
FR PVC insulated stranded single core copper conductor cable
650V grade, generally conforming to IS 694-1990 ,required qty
of copper earth socket, brass bolt and nut crimping/ soldering etc
complete with suitable size metal switch boxes with sheet
thickness 1.63mm, 50mm deep, neatly painted with enamel paint,
3mm thick phenolic laminated sheet front cover (6 mm sheets for
boxes of size 375x300 mm and above) fixed with steel screws,
cup washers etc.upto and including 6A piano type SP switches
and making good the surface of wall, colour washing etc.
complete. All the terminations in the switch boards and DB's
shall be tinned and the wires shall be drawn and fixed along the
periphery of the box using suitable ties, tie mounts etc as
required.

Short point rates


a1 Single control light point with 6A, 3 plate ceiling rose E 530.00
a2 Twin control light point with 6A, 3 plate ceiling rose E 816.00
a3 Single control light point with 6A, 5 pin plug socket mounted on
suitable size MS box with phenolic laminated front cover in place
of ceiling rose E 663.00
a4 Single control light point without ceiling rose E 501.00
a5 Twin control light point without ceiling rose E 775.00
a6 Single control ceiling fan point with 6A, 3 plate ceiling rose &
with regulator box suitable for mounting resistance type
regulator. E 646.00
a7 Single control ceiling fan point with 6 A, 3 plate ceiling rose &
with socket type electronic regulator. E 808.00
a8 Call bell point with piano type 6 A bell push at one end and 6 A,
3 plate ceiling rose at other end E 532.00
a9 Combined plug point with 6 A, 5 pin plug socket controlled by 6
A switch in the same switch board as that of light points.
E 237.00
Medium point rates
b1 Single control light point with 6A, 3 plate ceiling rose E 638.00
b2 Twin control light point with 6A, 3 plate ceiling rose E 977.00
b3 Single control light point with 6A, 5 pin plug socket mounted on
suitable size MS box with phenolic laminated front cover in place
of ceiling rose E 788.00
b4 Single control light point without ceiling rose E 609.00
b5 Twin control light point without ceiling rose E 936.00
b6 Single control ceiling fan point with 6A, 3 plate ceiling rose &
with regulator box suitable for mounting resistance type
regulator. E 743.00
b7 Single control ceiling fan point with 6 A, 3 plate ceiling rose &
with socket type electronic regulator. E 912.00
b8 Call bell point with piano type 6 A bell push at one end and 6 A,
3 plate ceiling rose at other end E 640.00
b9 Combined plug point with 6 A, 5 pin plug socket controlled by 6
A switch in the same switch board as that of light points.
E 279.00
Long point rates
c1 Single control light point with 6A, 3 plate ceiling rose E 754.00
c2 Twin control light point with 6A, 3 plate ceiling rose E 1157.00
c3 Single control light point with 6A, 5 pin plug socket mounted on
suitable size MS box with phenolic laminated front cover in place
of ceiling rose E 919.00
c4 Single control light point without ceiling rose E 698.00
c5 Twin control light point without ceiling rose E 1080.00
c6 Single control ceiling fan point with 6A, 3 plate ceiling rose &
with regulator box suitable for mounting resistance type
regulator. E 863.00
c7 Single control ceiling fan point with 6 A, 3 plate ceiling rose &
with socket type electronic regulator. E 1034.00
c8 Call bell point with piano type 6 A bell push at one end and 6 A,
3 plate ceiling rose at other end E 756.00
c9 Combined plug point with 6 A, 5 pin plug socket controlled by 6
A switch in the same switch board as that of light points.
E 308.00
Wiring points through existing PVC conduit and with MS box
& piano type accessories
121 Supply and wiring points according to IS 732-1989 through the
existing conduit with 1.00 sq mm PVC insulated stranded single
core copper conductor cable 650V grade,and continuous earthing
with 1.5 Sq.mm green coloured FR PVC insulated stranded
single core copper conductor cable 650V grade, generally
conforming to IS 694-1990 complete with suitable size metal
switch boxes with sheet thickness 1.63mm, 50mm deep, neatly
painted with enamel paint, 3mm thick phenolic laminated sheet
front cover (6 mm sheets for boxes of size 375x300 mm and
above) fixed with steel screws, cup washers etc. up to and
including 6A piano type SP switches and making good the surface
of wall, colour washing etc. complete. All the terminations in the
switch boards and DB's shall be tinned and the wires shall be
drawn and fixed along the periphery of the box using suitable
ties, tie mounts etc as required.

Short point rates


a1 Single control light point with 6A, 3 plate ceiling rose E 357.00
a2 Twin control light point with 6A, 3 plate ceiling rose E 556.00
a3 Single control light point with 6A, 5 pin plug socket mounted on
suitable size MS box with phenolic laminated front cover in place
of ceiling rose E 465.00
a4 Single control light point without ceiling rose E 330.00
a5 Twin control light point without ceiling rose E 508.00
a6 Single control ceiling fan point with 6A, 3 plate ceiling rose &
with regulator box suitable for mounting resistance type
regulator. E 451.00
a7 Single control ceiling fan point with 6 A, 3 plate ceiling rose &
with socket type electronic regulator. E 620.00
a8 Call bell point with piano type 6 A bell push at one end and 6 A,
3 plate ceiling rose at other end E 359.00
a9 Combined plug point with 6 A, 5 pin plug socket controlled by 6
A switch in the same switch board as that of light points.
E 255.00
Medium point rates
b1 Single control light point with 6A, 3 plate ceiling rose E 423.00
b2 Twin control light point with 6A, 3 plate ceiling rose E 654.00
b3 Single control light point with 6A, 5 pin plug socket mounted on
suitable size MS box with phenolic laminated front cover in place E 542.00
of ceiling rose
b5 Twin control light point without ceiling rose E 423.00
b6 Single control ceiling fan point with 6A, 3 plate ceiling rose &
with regulator box suitable for mounting resistance type
regulator. E 514.00
b7 Single control ceiling fan point with 6 A, 3 plate ceiling rose &
with socket type electronic regulator. E 683.00
b8 Call bell point with piano type 6 A bell push at one end and 6 A,
3 plate ceiling rose at other end E 424.00
b9 Combined plug point with 6 A, 5 pin plug socket controlled by 6
A switch in the same switch board as that of light points.
E 279.00
Long point rates
c1 Single control light point with 6A, 3 plate ceiling rose E 490.00
c2 Twin control light point with 6A, 3 plate ceiling rose E 760.00
c3 Single control light point with 6A, 5 pin plug socket mounted on
suitable size MS box with phenolic laminated front cover in place E 618.00
c4 of ceiling
Single rose light point without ceiling rose
control E 463.00
c5 Twin control light point without ceiling rose E 728.00
c6 Single control ceiling fan point with 6A, 3 plate ceiling rose &
with regulator box suitable for mounting resistance type
regulator. E 583.00
c7 Single control ceiling fan point with 6 A, 3 plate ceiling rose &
with socket type electronic regulator. E 754.00
c8 Call bell point with piano type 6 A bell push at one end and 6 A,
3 plate ceiling rose at other end E 492.00
c9 Combined plug point with 6 A, 5 pin plug socket controlled by 6
A switch in the same switch board as that of light points.
E 326.00

Wiring points with PVC conduit, modular box with white front
plate & modular type accessories (Group A)
122 Supply and wiring points according to IS 732-1989 using rigid
PVC conduit of minimum size 20 mm conforming to IS 9537 part
III 1983 and with suitable size specials conforming to IS 3419-
1988, fixing the conduit using metal saddles spacing not
exceeding 50 cm or concealed suitably and with 1.00 sq mm PVC
insulated stranded single core copper conductor cable 650V
grade,and continuous earthing with 1.5 Sq.mm green coloured
FR PVC insulated stranded single core copper conductor cable
650V grade, generally conforming to IS 694-1990 complete with
suitable size modular type metal switch boxes, modular type front
plates (white) etc. up to and including 6 A modular type SP
switches and making good the surface of wall, colour washing
etc. complete. All the terminations in the switch boards and DB's
shall be tinned and the wires shall be drawn and fixed along the
periphery of the box using suitable ties, tie mounts etc as
required. (Group A modular accessories)

Short point rates


a1 Single control light point with 6A, 3 plate ceiling rose E 551.00
a2 Twin control light point with 6A, 3 plate ceiling rose E 874.00
a3 Single control light point with 6A, 5 pin plug socket mounted on
modular type metal box with front plate in place of ceiling rose
E 738.00
a4 Single control light point without ceiling rose E 521.00
a5 Twin control light point without ceiling rose E 838.00
a6 Single control ceiling fan point with 6 A, 3 plate ceiling rose &
with socket size stepped electronic regulator. E 921.00
a7 Call bell point with piano type 6 A bell push at one end and 6 A,
3 plate ceiling rose at other end E 560.00
a8 Combined plug point with 6 A, 5 pin plug socket controlled by 6
A switch in the same switch board as that of light points.
E 370.00

Medium point rates


b1 Single control light point with 6A, 3 plate ceiling rose E 658.00
b2 Twin control light point with 6A, 3 plate ceiling rose E 1031.00
b3 Single control light point with 6A, 5 pin plug socket mounted on
modular type metal box with front plate in place of ceiling rose
E 857.00
b4 Single control light point without ceiling rose E 628.00
b5 Twin control light point without ceiling rose E 995.00
b6 Single control ceiling fan point with 6 A, 3 plate ceiling rose &
with socket size stepped electronic regulator. E 1020.00
b7 Call bell point with piano type 6 A bell push at one end and 6 A,
3 plate ceiling rose at other end E 667.00
b8 Combined plug point with 6 A, 5 pin plug socket controlled by 6
A switch in the same switch board as that of light points.
E 376.00
Long point rates
c1 Single control light point with 6A, 3 plate ceiling rose E 773.00
c2 Twin control light point with 6A, 3 plate ceiling rose E 1211.00
c3 Single control light point with 6A, 5 pin plug socket mounted on
modular type metal box with front plate in place of ceiling rose
E 987.00
c4 Single control light point without ceiling rose E 743.00
c5 Twin control light point without ceiling rose E 1176.00
c6 Single control ceiling fan point with 6 A, 3 plate ceiling rose &
with socket size stepped electronic regulator. E 1160.00
c7 Call bell point with piano type 6 A bell push at one end and 6 A,
3 plate ceiling rose at other end E 782.00
c8 Combined plug point with 6 A, 5 pin plug socket controlled by 6
A switch in the same switch board as that of light points.
E 432.00
Wiring points through existing conduit & with modular box
with white front plate and modular type accessories (Group A)

123 Supply and wiring points according to IS 732-1989 through the


existing conduit with 1.00 sq mm PVC insulated stranded single
core copper conductor cable 650V grade, and continuous
earthing with 1.5 Sq.mm green coloured FR PVC insulated
stranded single core copper conductor cable 650V grade,
generally conforming to IS 694-1990 complete with suitable size
modular type metal switch boxes, modular type front plates
(white) etc. up to and including 6 A modular type SP switches
and making good the surface of wall, colour washing etc.
complete. All the terminations in the switch boards and DB's
shall be tinned and the wires shall be drawn and fixed along the
periphery of the box using suitable ties, tie mounts etc as
required. (Group A modular accessories)

Short point rates


a1 Single control light point with 6A, 3 plate ceiling rose E 377.00
a2 Twin control light point with 6A, 3 plate ceiling rose E 614.00
a3 Single control light point with 6A, 5 pin plug socket mounted on
modular type metal box with front plate in place of ceiling rose
E 540.00
a4 Single control light point without ceiling rose E 351.00
a5 Twin control light point without ceiling rose E 581.00
a6 Single control ceiling fan point with 6 A, 3 plate ceiling rose &
with socket size stepped electronic regulator. E 736.00
a7 Call bell point with piano type 6 A bell push at one end and 6 A,
3 plate ceiling rose at other end E 386.00
a8 Combined plug point with 6 A, 5 pin plug socket controlled by 6
A switch in the same switch board as that of light points.
E 370.00
Medium point rates
b1 Single control light point with 6A, 3 plate ceiling rose E 442.00
b2 Twin control light point with 6A, 3 plate ceiling rose E 711.00
b3 Single control light point with 6A, 5 pin plug socket mounted on
modular type metal box with front plate in place of ceiling rose
E 611.00
b4 Single control light point without ceiling rose E 417.00
b5 Twin control light point without ceiling rose E 681.00
b6 Single control ceiling fan point with 6 A, 3 plate ceiling rose &
with socket size stepped electronic regulator. E 791.00
b7 Call bell point with piano type 6 A bell push at one end and 6 A,
3 plate ceiling rose at other end E 451.00
b8 Combined plug point with 6 A, 5 pin plug socket controlled by 6
A switch in the same switch board as that of light points.
E 376.00
Long point rates
c1 Single control light point with 6A, 3 plate ceiling rose E 510.00
c2 Twin control light point with 6A, 3 plate ceiling rose E 817.00
c3 Single control light point with 6A, 5 pin plug socket mounted on
modular type metal box with front plate in place of ceiling rose
E 686.00
c4 Single control light point without ceiling rose E 482.00
c5 Twin control light point without ceiling rose E 784.00
c6 Single control ceiling fan point with 6 A, 3 plate ceiling rose &
with socket size stepped electronic regulator. E 874.00
c7 Call bell point with piano type 6 A bell push at one end and 6 A,
3 plate ceiling rose at other end E 519.00
c8 Combined plug point with 6 A, 5 pin plug socket controlled by 6
A switch in the same switch board as that of light points.
E 432.00
Wiring points with PVC conduit, modular box with white/ off
white front plate & modular type accessories (Group B)
124 Supply and wiring points according to IS 732-1989 using rigid
PVC conduit of minimum size 20 mm with specials conforming
to IS 9537 part III 1983 and with suitable size specials
conforming to IS 3419-1988, fixing the conduit using metal
saddles spacing not exceeding 50 cm or concealed suitably and
with 1.00 sq mm PVC insulated stranded single core copper
conductor cable 650V grade, and continuous earthing with 1.5
Sq.mm green coloured FR PVC insulated stranded single core
copper conductor cable 650V grade, generally conforming to IS
694-1990 complete with suitable size modular type metal switch
boxes, modular type front plates (white or off white) etc. up to
and including 6 A modular type SP switches and making good the
surface of wall, colour washing etc. complete. All the
terminations in the switch boards and DB's shall be tinned and the
wires shall be drawn and fixed along the periphery of the box
using suitable ties, tie mounts etc as required. (Group B modular
accessories)

Short point rates


a1 Single control light point with 6A, 3 plate ceiling rose E 588.00
a2 Twin control light point with 6A, 3 plate ceiling rose E 926.00
a3 Single control light point with 6A, 5 pin plug socket mounted on
modular type metal box with front plate in place of ceiling rose
E 843.00
a4 Single control light point without ceiling rose E 558.00
a5 Twin control light point without ceiling rose E 917.00
a6 Single control ceiling fan point with 6 A, 3 plate ceiling rose &
with socket size stepped electronic regulator. E 1056.00
a7 Call bell point with piano type 6 A bell push at one end and 6 A,
3 plate ceiling rose at other end E 609.00
a8 Combined plug point with 6 A, 5 pin plug socket controlled by 6
A switch in the same switch board as that of light points.
E 453.00
Medium point rates
b1 Single control light point with 6A, 3 plate ceiling rose E 697.00
b2 Twin control light point with 6A, 3 plate ceiling rose E 1088.00
b3 Single control light point with 6A, 5 pin plug socket mounted on
modular type metal box with front plate in place of ceiling rose
E 964.00
b4 Single control light point without ceiling rose E 667.00
b5 Twin control light point without ceiling rose E 1079.00
b6 Single control ceiling fan point with 6 A, 3 plate ceiling rose &
with socket size stepped electronic regulator. E 1164.00
b7 Call bell point with piano type 6 A bell push at one end and 6 A,
3 plate ceiling rose at other end E 719.00
b8 Combined plug point with 6 A, 5 pin plug socket controlled by 6
A switch in the same switch board as that of light points.
E 459.00
Long point rates
c1 Single control light point with 6A, 3 plate ceiling rose E 811.00
c2 Twin control light point with 6A, 3 plate ceiling rose E 1293.00
c3 Single control light point with 6A, 5 pin plug socket mounted on
modular type metal box with front plate in place of ceiling rose
E 1093.00
c4 Single control light point without ceiling rose E 781.00
c5 Twin control light point without ceiling rose E 1257.00
c6 Single control ceiling fan point with 6 A, 3 plate ceiling rose &
with socket size stepped electronic regulator. E 1306.00
c7 Call bell point with piano type 6 A bell push at one end and 6 A,
3 plate ceiling rose at other end E 833.00
c8 Combined plug point with 6 A, 5 pin plug socket controlled by 6
A switch in the same switch board as that of light points.
E 516.00
Wiring points through existing PVC conduit & with modular
box with white/ off white front plate and modular type
accessories (Group B)
125 Supply and wiring points according to IS 732-1989 through the
existing conduit with 1.00 sq mm PVC insulated stranded single
core copper conductor cable 650V grade, and continuous
earthing with 1.5 Sq.mm green coloured FR PVC insulated
stranded single core copper conductor cable 650V grade,
generally conforming to IS 694-1990 complete with suitable size
modular type metal switch boxes, modular type front plates
(white or off white) etc. up to and including 6 A modular type SP
switches and making good the surface of wall, colour washing
etc. complete. All the terminations in the switch boards and DB's
shall be tinned and the wires shall be drawn and fixed along the
periphery of the box using suitable ties, tie mounts etc as
required. (Group B modular accessories)

Short point rates


a1 Single control light point with 6A, 3 plate ceiling rose E 411.00
a2 Twin control light point with 6A, 3 plate ceiling rose E 693.00
a3 Single control light point with 6A, 5 pin plug socket mounted on
modular type metal box with front plate in place of ceiling rose
E 645.00
a4 Single control light point without ceiling rose E 387.00
a5 Twin control light point without ceiling rose E 660.00
a6 Single control ceiling fan point with 6 A, 3 plate ceiling rose &
with socket size stepped electronic regulator. E 872.00
a7 Call bell point with piano type 6 A bell push at one end and 6 A,
3 plate ceiling rose at other end E 436.00
a8 Combined plug point with 6 A, 5 pin plug socket controlled by 6
A switch in the same switch board as that of light points.
E 453.00
Medium point rates
b1 Single control light point with 6A, 3 plate ceiling rose E 481.00
b2 Twin control light point with 6A, 3 plate ceiling rose E 794.00
b3 Single control light point with 6A, 5 pin plug socket mounted on
modular type metal box with front plate in place of ceiling rose
E 719.00
b4 Single control light point without ceiling rose E 456.00
b5 Twin control light point without ceiling rose E 765.00
b6 Single control ceiling fan point with 6 A, 3 plate ceiling rose &
with socket size stepped electronic regulator. E 934.00
b7 Call bell point with piano type 6 A bell push at one end and 6 A,
3 plate ceiling rose at other end E 503.00
b8 Combined plug point with 6 A, 5 pin plug socket controlled by 6
A switch in the same switch board as that of light points.
E 459.00
Long point rates
c1 Single control light point with 6A, 3 plate ceiling rose E 548.00
c2 Twin control light point with 6A, 3 plate ceiling rose E 898.00
c3 Single control light point with 6A, 5 pin plug socket mounted on
modular type metal box with front plate in place of ceiling rose
E 792.00
c4 Single control light point without ceiling rose E 520.00
c5 Twin control light point without ceiling rose E 865.00
c6 Single control ceiling fan point with 6 A, 3 plate ceiling rose &
with socket size stepped electronic regulator. E 1025.00
c7 Call bell point with piano type 6 A bell push at one end and 6 A,
3 plate ceiling rose at other end E 569.00
c8 Combined plug point with 6 A, 5 pin plug socket controlled by 6
A switch in the same switch board as that of light points.
E 516.00
PART III
SH: CARRIAGE AND ERECTION OF LIGHT FITTINGS

Conveyance & installation charges only


200 Conveyance, installation, testing and commissioning of pre-wired
fluorescent light fittings with all accessories and fluorescent
lamps of all types directly on wall and giving connections with
16/0.20 mm 3 core PVC insulated and sheathed round copper
conductor flex wire or extending the original wiring and giving
connections as required
E 92.50
201 Conveyance installation testing and commissioning of pre-wired
fluorescent fittings of all types complete with all accessories and
fluorescent lamps etc. directly on wall or ceiling with T.W round
block neatly painted to suit the fitting and giving connection with
required length of 16/0.20mm 3 core copper conductor flex wire
conforming to relevant ISS or extending the original wiring and
giving connections as required.

E 116.50
202 Conveyance, installation, testing and commissioning of pre-wired
fluorescent fitting of all types complete with all accessories and
fluorescent lamps etc. directly on wall/ ceiling using 2 nos. C/U
shaped brackets made from 20 x 3 mm MS flat, painting the flat
iron bracket and giving connections with required length of
16/0.20mm 3 core copper conductor flex wire conforming to
relevant ISS or extending the original wiring and giving
connection etc. as required.
E 123.00
203 Conveyance, installation, testing and commissioning of pre-wired
fluorescent fitting of all types complete with all accessories and
fluorescent lamps etc. directly on wall using 2 nos. flat iron
brackets made from 25x6mm flat iron, painting the flat iron
bracket and giving connections with required length of
16/0.20mm 3 core copper conductor flex wire conforming to
relevant ISS or extending the original wiring and giving
connection etc. as required.
E 159.00
204 Conveyance, installation, testing and commissioning of pre-wired
fluorescent fitting of all types complete with all accessories and
fluorescent lamps etc. suspended from ceiling using 2 nos steel
chain (16 SWG or nearest available size) of length not exceeding
30 cm properly hooked to steel hooks anchored to the ceiling and
giving connections with required length of 16/0.20mm 3 core
copper conductor flex wire conforming to relevant ISS or
extending the original wiring and giving connection etc. as
required.

E 98.50
205 Conveyance installation testing and commissioning of 600 x 600
mm pre-wired fluorescent fitting of all types complete with all
accessories and fluorescent lamps etc. suspended from ceiling
using 4 nos steel chain (16 SWG or nearest available size) of
length not exceeding 30 cm properly hooked to steel hooks
anchored to the ceiling and giving connections with required
length of 16/0.20mm 3 core copper conductor flex wire
conforming to relevant ISS or extending the original wiring and
giving connection etc. as required.

E 109.00
206 Supplying and providing extra steel chain (16 SWG) 2 x 1.00 m
long with 16/0.20 mm 3 core copper conductor flex wire
conforming to relevant ISS or with the extended original wiring
and giving connection etc. as required.
E 61.50
207 Supplying and providing extra steel chain (16 SWG) 4 x 1.00 m
long with 16/0.20 mm 3 core copper conductor flex wire
conforming to relevant ISS or with the extended original wiring
and giving connection etc. as required.
E 89.00
208 Conveyance, installation, testing and commissioning of pre-wired
fluorescent fittings of all types complete with all accessories and
fluorescent lamps etc. including supplying and fixing ball and
socket arrangements on T.W round block, suspension down rod
of 19 mm dia MS conduit up to 2x30cm length including painting
and wiring the down rod with 16/0.20mm 3 core round copper
conductor flex wire conforming to relevant ISS or extending the
original wiring and giving connections etc. a required.

E 244.00
209 Supplying and providing extra H.G conduit down rod of 19 mm
dia 2 x 1.00 m long with 16/0.20 mm 3 core copper conductor
flex wire conforming to relevant ISS or with the extended
original wiring and giving connection etc. as required.

m 177.00
210 Conveyance, installation, testing and commissioning of pre-wired
fluorescent fittings of all types complete with all accessories and
fluorescent lamps etc. including supplying and fixing ball and
socket arrangements on T.W round block, suspension down rod
of 16 mm dia MS conduit up to 2x30cm length including painting
and wiring the down rod with 16/0.20mm 3 core round copper
conductor flex wire conforming to relevant ISS or extending the
original wiring and giving connections etc. a required.

E 236.00
211 Supplying and providing extra H.G conduit down rod of 16 mm
dia 2 x 1.00 m long with 16/0.20 mm 3 core copper conductor
flex wire conforming to relevant ISS or with the extended
original wiring and giving connection etc. as required.

m 118.00
212 Conveyance, installation, testing and commissioning of surface
mounting down light fittings of all types directly on ceiling
including giving connections with required length of 16/0.20 mm
3 core round copper conductor flex wire conforming to relevant
ISS or with the extended original wiring etc as required

E 50.00
213 Conveyance, installation, testing and commissioning of recess
mounting down light fittings of all types directly in the existing
opening on the false - ceiling including giving connections with
required length of 16/0.20 mm 3 core round copper conductor
flex wire conforming to relevant ISS or with the extended
original wiring etc as required
E 30.00
214 Conveyance, installation, testing and commissioning of
ornamental type wall light fittings of all types directly on wall
including giving connections with required length of 16/0.20 mm
3 core round copper conductor flex wire conforming to relevant
ISS or with the extended original wiring, making good the
damages, colour washing etc as required

E 45.00
215 Conveyance, installation, testing and commissioning of foot light/
skirt light fittings of all types directly on wall including cutting
necessary holes, giving connections with the extended original
wiring, making good the damages, colour washing etc as required

E 75.00
216 Conveyance, installation, testing and commissioning of post-top
lantern/ outdoor type FTL/ CFL fittings of all types directly on
the existing pipe/ pole and giving connections with the existing
wiring etc as required
E 42.00
217 Conveyance, installation, testing and commissioning of T 5
outdoor light fitting with 4 Nos lamps/ SV/ MH/ CDMT light
fittings with all accessories and lamp etc. of all types directly on
the existing pipe/ pole including giving connections with the
existing wiring etc as required
E 88.50
218 Supply, conveyance and erection of the following sizes of 'B'
class GI pipe in single section for post top lantern fittings of all
types (excluding excavation & concrete base) and painting with
2 coats of synthetic enamel paint over a coat of zinc chromate
primer etc. as required.
a 32 mm dia m 176.00
b 40 mm dia m 210.00
c 50 mm dia m 251.00
219 Supply, fabrication, conveyance and fixing the following sizes of
B class GI pipe bent to shape / cut and welded to shape and
fixing the same to wall / parapet using clamps as noted along with
each size, painting with 2 coats of synthetic enamel paint over a
coat of zinc chromate primer, making good the damages, colour
washing etc as required (for the installation of outdoor light
fittings).

a 25 mm dia with HG company fabricated clamps m 224.00


b 32 mm dia with clamps made from 20 x 3 mm MS flat m 249.00
c 40 mm dia with clamps made from 20 x 3 mm MS flat m 287.00
d 50 mm dia with clamps made from 25 x 3 mm MS flat m 329.00
Supply & installation of fluorescent fittings directly on wall

225 Supply conveyance, installation, testing and commissioning the


following types of fluorescent light fittings with all accessories
and fluorescent lamps directly on wall and giving connections
with 16/0.20 mm 3 core PVC insulated and sheathed round
copper conductor flex wire or extending the original wiring and
giving connections as required
A Fluorescent tube light fitting with lamp holder, APF electronic
ballast suitable for continuous operation with THD <10%, power
factor >0.98, RoHS compliant, duly wired up for use on 230 V
AC supply . The fittings shall be made from CRCA MS sheet of
minimum thickness 0.50 mm nominal thickness inside & outside.

a1 Suitable for single 28 W T5 lamp E 1402.00


a2 Suitable for twin 28 W T5 lamps E 2015.00
B Fluorescent tube light fitting with lamp holder, electronic ballast
suitable for continuous operation with THD <10% duly wired up
for use on 230 V AC supply . The fittings shall be made from
CRCA MS sheet of minimum thickness 0.50 mm nominal
thickness inside & outside.
b1 Suitable for single 28 W T5 lamp E 1033.00
b2 Suitable for twin 28 W T5 lamps E 1525.00
C Fluorescent tube light fitting with bi-directional reflector
complete with lamp holder, APF electronic ballast suitable for
continuous operation with THD <10%, power factor >0.98, RoHS
compliant, duly wired up for use on 230 V AC supply . The
fittings shall be made from CRCA MS sheet of minimum
thickness 0.50 mm nominal thickness inside & outside.

c1 Suitable for single 28 W T5 lamp E 1606.00


c2 Suitable for twin 28 W T5 lamps E 2260.00
D Fluorescent tube light fitting with bi-directional reflector
complete with lamp holder, electronic ballast suitable for
continuous operation with THD <10%, duly wired up for use on
230 V AC supply . The fittings shall be made from CRCA MS
sheet of minimum thickness 0.50 mm nominal thickness inside &
outside.
d1 Suitable for single 28 W T5 lamp E 1319.00
d2 Suitable for twin 28 W T5 lamps E 1770.00

Supply & installation of fluorescent fittings on TW round block

226 Supply, conveyance installation testing and commissioning of


pre-wired fluorescent fittings of the following types complete
with all accessories and fluorescent lamps etc. directly on wall or
ceiling with T.W round block neatly painted to suit the fitting and
giving connection with required length of 16/0.20mm 3 core
copper conductor flex wire conforming to relevant ISS and giving
connections as required.
A Fluorescent tube light fitting with lamp holder, APF electronic
ballast suitable for continuous operation with THD <10%, power
factor >0.98, RoHS compliant, duly wired up for use on 230 V
AC supply . The fittings shall be made from CRCA MS sheet of
minimum thickness 0.50 mm nominal thickness inside & outside.

a1 Suitable for single 28 W T5 lamp E 1426.00


a2 Suitable for twin 28 W T5 lamps E 2039.00
B Fluorescent tube light fitting with lamp holder, electronic ballast
suitable for continuous operation with THD <10% duly wired up
for use on 230 V AC supply . The fittings shall be made from
CRCA MS sheet of minimum thickness 0.50 mm nominal
thickness inside & outside.

b1 Suitable for single 28 W T5 lamp E 1057.00


b2 Suitable for twin 28 W T5 lamps E 1549.00
C Fluorescent tube light fitting with bi-directional reflector
complete with lamp holder, APF electronic ballast suitable for
continuous operation with THD <10%, power factor >0.98, RoHS
compliant, duly wired up for use on 230 V AC supply . The
fittings shall be made from CRCA MS sheet of minimum
thickness 0.50 mm nominal thickness inside & outside.

c1 Suitable for single 28 W T5 lamp E 1630.00


c2 Suitable for twin 28 W T5 lamps E 2284.00
D Fluorescent tube light fitting with bi-directional reflector
complete with lamp holder, electronic ballast suitable for
continuous operation with THD <10%, duly wired up for use on
230 V AC supply . The fittings shall be made from CRCA MS
sheet of minimum thickness 0.50 mm nominal thickness inside &
outside.

d1 Suitable for single 28 W T5 lamp E 1343.00


d2 Suitable for twin 28 W T5 lamps E 1794.00

Supply & installation of fluorescent fittings on 'C/U' shaped flat


iron bracket
227 Supply, conveyance, installation, testing and commissioning of
pre-wired fluorescent fitting of the following types complete with
all accessories and fluorescent lamps etc. directly on wall using 2
nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the
flat iron bracket and giving connections with required length of
16/0.20mm 3 core copper conductor flex wire conforming to
relevant ISS or extending the original wiring and giving
connection etc. as required.

A Fluorescent tube light fitting with lamp holder, APF electronic


ballast suitable for continuous operation with THD <10%, power
factor >0.98, RoHS compliant, duly wired up for use on 230 V
AC supply . The fittings shall be made from CRCA MS sheet of
minimum thickness 0.50 mm nominal thickness inside & outside.

a1 Suitable for single 28 W T5 lamp E 1432.00


a2 Suitable for twin 28 W T5 lamps E 2045.00
B Fluorescent tube light fitting with lamp holder, electronic ballast
suitable for continuous operation with THD <10% duly wired up
for use on 230 V AC supply . The fittings shall be made from
CRCA MS sheet of minimum thickness 0.50 mm nominal
thickness inside & outside.

b1 Suitable for single 28 W T5 lamp E 1064.00


b2 Suitable for twin 28 W T5 lamps E 1555.00
C Fluorescent tube light fitting with bi-directional reflector
complete with lamp holder, APF electronic ballast suitable for
continuous operation with THD <10%, power factor >0.98, RoHS
compliant, duly wired up for use on 230 V AC supply . The
fittings shall be made from CRCA MS sheet of minimum
thickness 0.50 mm nominal thickness inside & outside.

c1 Suitable for single 28 W T5 lamp E 1636.00


c2 Suitable for twin 28 W T5 lamps E 2290.00
D Fluorescent tube light fitting with bi-directional reflector
complete with lamp holder, electronic ballast suitable for
continuous operation with THD <10%, duly wired up for use on
230 V AC supply . The fittings shall be made from CRCA MS
sheet of minimum thickness 0.50 mm nominal thickness inside &
outside.

d1 Suitable for single 28 W T5 lamp E 1350.00


d2 Suitable for twin 28 W T5 lamps E 1800.00

Supply & installation of fluorescent fittings on flat iron bracket

228 Supply, conveyance, installation, testing and commissioning of


pre-wired fluorescent fitting of the following types complete with
all accessories and fluorescent lamps etc. directly on wall using 2
nos. flat iron brackets made from 25x6mm flat iron, painting the
flat iron bracket and giving connections with required length of
16/0.20mm 3 core copper conductor flex wire conforming to
relevant ISS or extending the original wiring and giving
connection etc. as required.

A Fluorescent tube light fitting with lamp holder, APF electronic


ballast suitable for continuous operation with THD <10%, power
factor >0.98, RoHS compliant, duly wired up for use on 230 V
AC supply . The fittings shall be made from CRCA MS sheet of
minimum thickness 0.50 mm nominal thickness inside & outside.

a1 Suitable for single 28 W T5 lamp E 1468.00


a2 Suitable for twin 28 W T5 lamps E 2081.00
B Fluorescent tube light fitting with lamp holder, electronic ballast
suitable for continuous operation with THD <10% duly wired up
for use on 230 V AC supply . The fittings shall be made from
CRCA MS sheet of minimum thickness 0.50 mm nominal
thickness inside & outside.

b1 Suitable for single 28 W T5 lamp E 1100.00


b2 Suitable for twin 28 W T5 lamps E 1591.00
C Fluorescent tube light fitting with bi-directional reflector
complete with lamp holder, APF electronic ballast suitable for
continuous operation with THD <10%, power factor >0.98, RoHS
compliant, duly wired up for use on 230 V AC supply . The
fittings shall be made from CRCA MS sheet of minimum
thickness 0.50 mm nominal thickness inside & outside.
c1 Suitable for single 28 W T5 lamp E 1672.00
c2 Suitable for twin 28 W T5 lamps E 2326.00
D Fluorescent tube light fitting with bi-directional reflector
complete with lamp holder, electronic ballast suitable for
continuous operation with THD <10%, duly wired up for use on
230 V AC supply . The fittings shall be made from CRCA MS
sheet of minimum thickness 0.50 mm nominal thickness inside &
outside.

d1 Suitable for single 28 W T5 lamp E 1386.00


d2 Suitable for twin 28 W T5 lamps E 1836.00

Supply & installation of fluorescent fittings suspended on steel


chain
229 Supply, conveyance, installation, testing and commissioning of
pre-wired fluorescent fitting of the following types complete with
all accessories and fluorescent lamps etc. suspended from ceiling
using 2 nos steel chain of length not exceeding 30 cm properly
hooked to steel hooks anchored to the ceiling and giving
connections with required length of 16/0.20mm 3 core copper
conductor flex wire conforming to relevant ISS or extending the
original wiring and giving connection etc. as required.

A Fluorescent tube light fitting with lamp holder, APF electronic


ballast suitable for continuous operation with THD <10%, power
factor >0.98, RoHS compliant, duly wired up for use on 230 V
AC supply . The fittings shall be made from CRCA MS sheet of
minimum thickness 0.50 mm nominal thickness inside & outside.

a1 Suitable for single 28 W T5 lamp E 1408.00


a2 Suitable for twin 28 W T5 lamps E 2021.00
B Fluorescent tube light fitting with lamp holder, electronic ballast
suitable for continuous operation with THD <10% duly wired up
for use on 230 V AC supply . The fittings shall be made from
CRCA MS sheet of minimum thickness 0.50 mm nominal
thickness inside & outside.

b1 Suitable for single 28 W T5 lamp E 1039.00


b2 Suitable for twin 28 W T5 lamps E 1531.00
C Fluorescent tube light fitting with bi-directional reflector
complete with lamp holder, APF electronic ballast suitable for
continuous operation with THD <10%, power factor >0.98, RoHS
compliant, duly wired up for use on 230 V AC supply . The
fittings shall be made from CRCA MS sheet of minimum
thickness 0.50 mm nominal thickness inside & outside.

c1 Suitable for single 28 W T5 lamp E 1612.00


c2 Suitable for twin 28 W T5 lamps E 2266.00
D Fluorescent tube light fitting with bi-directional reflector
complete with lamp holder, electronic ballast suitable for
continuous operation with THD <10%, duly wired up for use on
230 V AC supply . The fittings shall be made from CRCA MS
sheet of minimum thickness 0.50 mm nominal thickness inside &
outside.

d1 Suitable for single 28 W T5 lamp E 1325.00


d2 Suitable for twin 28 W T5 lamps E 1776.00
E Surface mounting decorative fluorescent tube light fitting (Cat-2)
complete with lamp holder, APF electronic ballast suitable for
continuous operation with THD <10%, power factor >0.98, RoHS
compliant, duly wired up for use on 230 V AC supply

e1 Suitable for single 28 W T5 lamp E 2053.00


e2 Suitable for twin 28 W T5 lamps E 2446.00
Suitable for twin 28 W T5 lamps with housing of high technology
e3 form E 4106.00
F Surface mounting decorative fluorescent tube light fitting (Cat-2)
complete with lamp holder, electronic ballast suitable for
continuous operation with THD <10%, duly wired up for use on
230 V AC supply

f1 Suitable for single 28 W T5 lamp E 1766.00


f2 Suitable for twin 28 W T5 lamps E 2773.00
Suitable for twin 28 W T5 lamps with housing of high technology
f3 form E 3616.00

230 Supply, conveyance, installation, testing and commissioning of


pre-wired fluorescent fitting of the following types complete with
all accessories and fluorescent lamps etc. suspended from ceiling
using 4 nos steel chain of length not exceeding 30 cm properly
hooked to steel hooks anchored to the ceiling and giving
connections with required length of 16/0.20mm 3 core copper
conductor flex wire conforming to relevant ISS or extending the
original wiring and giving connection etc. as required.
A Surface mounting decorative fluorescent tube light fitting (Cat-2)
complete with lamp holder, APF electronic ballast suitable for
continuous operation with THD <10%, power factor >0.98, RoHS
compliant, duly wired up for use on 230 V AC supply

a1 Suitable for single 28 W T5 lamp E 2064.00


a2 Suitable for twin 28 W T5 lamps E 2456.00
Suitable for twin 28 W T5 lamps with housing of high technology
a3 form E 4116.00
B Surface mounting decorative fluorescent tube light fitting (Cat-2)
complete with lamp holder, electronic ballast suitable for
continuous operation with THD <10%, duly wired up for use on
230 V AC supply

b1 Suitable for single 28 W T5 lamp E 1777.00


b2 Suitable for twin 28 W T5 lamps E 2784.00
Suitable for twin 28 W T5 lamps with housing of high technology
b3 form E 3626.00
C Recess mounting decorative fluorescent tube light fitting (Cat-2)
complete with lamp holder, APF electronic ballast suitable for
continuous operation with THD <10%, power factor >0.98, RoHS
compliant, duly wired up for use on 230 V AC supply.

c1 Suitable for twin 28 W T5 lamps E 4304.00


c2 Suitable for 4 Nos 14 W T5 lamps E 5116.00
D Recess mounting decorative fluorescent tube light fitting (Cat-2)
complete with lamp holder, electronic ballast suitable for
continuous operation with THD <10%, duly wired up for use on
230 V AC supply.

d1 Suitable for twin 28 W T5 lamps E 3814.00


d2 Suitable for 4 Nos 14 W T5 lamps E 4462.00
E Recess mounting decorative direct - indirect fluorescent tube light
fitting complete with lamp holder, APF electronic ballast suitable
for continuous operation with THD <10%, power factor >0.98,
RoHS compliant, duly wired up for use on 230 V AC supply.

e1 Suitable for 4 Nos 14 W T5 lamps E 4993.00


F Recess mounting decorative direct - indirect fluorescent tube light
fitting complete with lamp holder, electronic ballast suitable for
continuous operation with THD <10%, duly wired up for use on
230 V AC supply.

f1 Suitable for 4 Nos 14 W T5 lamps E 4339.00


Supply & installation of fluorescent fittings suspended on ball
& socket arrangement with 19 mm down rod
231 Supply, conveyance, installation, testing and commissioning of
pre-wired fluorescent fittings of the following types complete
with all accessories and fluorescent lamps etc. including
supplying and fixing ball and socket arrangements on T.W round
block, suspension down rod of 19mm dia MS conduit up to
2x30cm length including painting and wiring the down rod with
16/0.20mm 3 core round copper conductor flex wire conforming
to relevant ISS or extending the original wiring and giving
connections etc. a required.

A Fluorescent tube light fitting with lamp holder, APF electronic


ballast suitable for continuous operation with THD <10%, power
factor >0.98, RoHS compliant, duly wired up for use on 230 V
AC supply without fluorescent tubes. The fittings shall be made
from CRCA MS sheet of minimum thickness 0.50 mm nominal
thickness inside & outside.

a1 Suitable for single 28 W T5 lamp E 1533.00


a2 Suitable for twin 28 W T5 lamps E 2166.00
B Fluorescent tube light fitting with lamp holder, electronic ballast
suitable for continuous operation with THD <10% duly wired up
for use on 230 V AC supply without fluorescent tubes. The
fittings shall be made from CRCA MS sheet of minimum
thickness 0.50 mm nominal thickness inside & outside.

b1 Suitable for single 28 W T5 lamp E 1185.00


b2 Suitable for twin 28 W T5 lamps E 1676.00
C Fluorescent tube light fitting with bi-directional reflector
complete with lamp holder, APF electronic ballast suitable for
continuous operation with THD <10%, power factor >0.98, RoHS
compliant, duly wired up for use on 230 V AC supply without
fluorescent tubes. The fittings shall be made from CRCA MS
sheet of minimum thickness 0.50 mm nominal thickness inside &
outside.

c1 Suitable for single 28 W T5 lamp E 1757.00


c2 Suitable for twin 28 W T5 lamps E 2411.00
D Fluorescent tube light fitting with bi-directional reflector
complete with lamp holder, electronic ballast suitable for
continuous operation with THD <10%, duly wired up for use on
230 V AC supply without fluorescent tubes. The fittings shall be
made from CRCA MS sheet of minimum thickness 0.50 mm
nominal thickness inside & outside.

d1 Suitable for single 28 W T5 lamp E 1471.00


d2 Suitable for twin 28 W T5 lamps E 1921.00
Supply & installation of fluorescent fittings suspended on ball
& socket arrangement with 16 mm down rod
232 Supply, conveyance, installation, testing and commissioning of
pre-wired fluorescent fittings of the following types complete
with all accessories and fluorescent lamps etc. including
supplying and fixing ball and socket arrangements on T.W round
block, suspension down rod of 16 mm dia MS conduit up to
2x30cm length including painting and wiring the down rod with
16/0.20mm 3 core round copper conductor flex wire conforming
to relevant ISS or extending the original wiring and giving
connections etc. a required.

A Fluorescent tube light fitting with lamp holder, APF electronic


ballast suitable for continuous operation with THD <10%, power
factor >0.98, RoHS compliant, duly wired up for use on 230 V
AC supply without fluorescent tubes. The fittings shall be made
from CRCA MS sheet of minimum thickness 0.50 mm nominal
thickness inside & outside.

a1 Suitable for single 28 W T5 lamp E 1545.00


a2 Suitable for twin 28 W T5 lamps E 2158.00
B Fluorescent tube light fitting with lamp holder, electronic ballast
suitable for continuous operation with THD <10% duly wired up
for use on 230 V AC supply without fluorescent tubes. The
fittings shall be made from CRCA MS sheet of minimum
thickness 0.50 mm nominal thickness inside & outside.

b1 Suitable for single 28 W T5 lamp E 1177.00


b2 Suitable for twin 28 W T5 lamps E 1668.00
C Fluorescent tube light fitting with bi-directional reflector
complete with lamp holder, APF electronic ballast suitable for
continuous operation with THD <10%, power factor >0.98, RoHS
compliant, duly wired up for use on 230 V AC supply without
fluorescent tubes. The fittings shall be made from CRCA MS
sheet of minimum thickness 0.50 mm nominal thickness inside &
outside.

c1 Suitable for single 28 W T5 lamp E 1749.00


c2 Suitable for twin 28 W T5 lamps E 2403.00
D Fluorescent tube light fitting with bi-directional reflector
complete with lamp holder, electronic ballast suitable for
continuous operation with THD <10%, duly wired up for use on
230 V AC supply without fluorescent tubes. The fittings shall be
made from CRCA MS sheet of minimum thickness 0.50 mm
nominal thickness inside & outside.

d1 Suitable for single 28 W T5 lamp E 1463.00


d2 Suitable for twin 28 W T5 lamps E 1913.00
E Surface mounting decorative fluorescent tube light fitting (Cat-2)
complete with lamp holder, APF electronic ballast suitable for
continuous operation with THD <10%, power factor >0.98, RoHS
compliant, duly wired up for use on 230 V AC supply

e1 Suitable for single 28 W T5 lamp E 2191.00


e2 Suitable for twin 28 W T5 lamps E 2583.00
Suitable for twin 28 W T5 lamps with housing of high technology
e3 form E 4243.00
F Surface mounting decorative fluorescent tube light fitting (Cat-2)
complete with lamp holder, electronic ballast suitable for
continuous operation with THD <10%, duly wired up for use on
230 V AC supply

f1 Suitable for single 28 W T5 lamp E 1904.00


f2 Suitable for twin 28 W T5 lamps E 2911.00
Suitable for twin 28 W T5 lamps with housing of high technology
f3 form E 3753.00
G Recess mounting decorative fluorescent tube light fitting (Cat-2)
complete with lamp holder, APF electronic ballast suitable for
continuous operation with THD <10%, power factor >0.98, RoHS
compliant, duly wired up for use on 230 V AC supply.
g1 Suitable for twin 28 W T5 lamps E 4431.00
g2 Suitable for 4 Nos 14 W T5 lamps E 5243.00
H Recess mounting decorative fluorescent tube light fitting (Cat-2)
complete with lamp holder, electronic ballast suitable for
continuous operation with THD <10%, duly wired up for use on
230 V AC supply.

h1 Suitable for twin 28 W T5 lamps E 3941.00


h2 Suitable for 4 Nos 14 W T5 lamps E 4589.00
I Recess mounting decorative direct - indirect fluorescent tube light
fitting complete with lamp holder, APF electronic ballast suitable
for continuous operation with THD <10%, power factor >0.98,
RoHS compliant, duly wired up for use on 230 V AC supply.

i1 Suitable for 4 Nos 14 W T5 lamps E 5120.00


J Recess mounting decorative direct - indirect fluorescent tube light
fitting complete with lamp holder, electronic ballast suitable for
continuous operation with THD <10%, duly wired up for use on
230 V AC supply.

j1 Suitable for 4 Nos 14 W T5 lamps E 4466.00

Supply & installation of Batten, Bracket & BH fittings


240 Supply and fixing angle / straight brass lined skirt type, bakelite
batten holder without shade and giving connection etc as required
E 60.00
241 Supplying and fixing cast Aluminium bracket with square base,
nipple with 12.70mm holder threads, projection 127mm, stove
enameled with brass bracket holder on suitable size painted MS
box with phenolic laminated sheet front cover and giving
connections with required length of 16/0.20mm PVC insulated
and PVC sheathed 2 core round copper conductor flex wire
conforming to relevant ISS or with the extended original wiring,
earthing the MS box, making good the surface of wall, colour
washing etc as required.

E 260.00
242 Supplying and fixing cast Aluminium bracket with round base,
nipple with 12.70mm holder threads, projection 130mm stove
enameled with brass bracket holder on suitable size painted MS
box with phenolic laminated sheet front cover and giving
connections with required length of 16/0.20mm PVC insulated
and PVC sheathed 2 core round copper conductor flex wire
conforming to relevant ISS or with the extended original wiring,
earthing the MS box, making good the surface of wall, colour
washing etc as required.

E 269.00
243 Supply and fixing shades of the following types of shades on
existing batten / pendent/bracket fittings as required
a 200mm EI conical shade E 40.00
b 250mm EI conical shade E 45.00
c 200mm polished aluminium shade. E 64.50
d 250mm polished aluminium shade. E 77.50
e 200 mm Plastic sill shade E 24.50
244 Supply and fixing cast aluminium elliptical shaped bulk head
fitting with front clear glass and mesh guard suitable for 5 to 14
W CFL to wall / ceiling including giving connections with
required length of 16/0.20mm PVC insulated and PVC sheathed 3
core round copper conductor flex wire conforming to relevant ISS
or extending the original wiring and making good the surface as
required.
E 419.00
245 Supply and fixing cast aluminium square shaped bulk head fitting
with front clear glass and mesh guard suitable for 5 to 14 W CFL
to wall / ceiling including giving connections with required length
of 16/0.20mm PVC insulated and PVC sheathed 3 core round
copper conductor flex wire conforming to relevant ISS or
extending the original wiring and making good the surface as
required.
E 447.00
246 Supply and fixing cast aluminium stove enameled bulk head
fitting with deep drawn anodised aluminium body, epoxy powder
coated, heat resistant prismatic glass cover suitable for 9 W CFL
to wall / ceiling including giving connections with required length
of 16/0.20mm PVC insulated and PVC sheathed 3 core round
copper conductor flex wire conforming to relevant ISS or
extending the original wiring and making good the surface as
required.
E 779.00
250 Supply and providing the following types and power rated lamps
in the existing fittings as required
a1 Dwarf size 5 W BC / ES / E14 retrofit CFL E 132.00
a2 Dwarf size 8 W BC / ES / E14 retrofit CFL E 139.00
a3 Dwarf size 11 W BC / ES / E14 retrofit CFL E 150.00
a4 Dwarf size 14 W BC / ES / E14 retrofit CFL E 168.00

b1 Normal size 8 W BC / ES retrofit CFL E 139.00


b2 Normal size 11 W BC / ES retrofit CFL E 145.00
b3 Normal size 14 W BC / ES retrofit CFL E 156.00
b4 Normal size 15 W BC / ES retrofit CFL E 156.00
b5 Normal size 18 W BC / ES retrofit CFL E 203.00
b6 Normal size 20 W BC / ES retrofit CFL E 203.00
b7 Normal size 23 W BC / ES retrofit CFL E 239.00
b8 Normal size 26 W BC / ES retrofit CFL E 274.00

c1 Higher size 35 W BC / ES retrofit CFL E 415.00


c2 Higher size 45 W BC / ES retrofit CFL E 615.00
c3 Higher size 65 W BC / ES retrofit CFL E 674.00
c4 Higher size 85 W BC / ES retrofit CFL E 745.00
d1 Spiral 7 W BC / ES retrofit CFL E 197.00
d2 Spiral 9 W BC / ES retrofit CFL E 197.00
d3 Spiral 11 W BC / ES retrofit CFL E 227.00
d4 Spiral 13 W BC / ES retrofit CFL E 235.00
d5 Spiral 15 W BC / ES retrofit CFL E 239.00
d6 Spiral 20 W BC / ES retrofit CFL E 262.00
d7 Spiral 23 W BC / ES retrofit CFL E 285.00
d8 Spiral 26 W BC / ES retrofit CFL E 279.00

f1 Globe 15 W BC retrofit CFL E 415.00


f2 Globe 20 W BC retrofit CFL E 504.00
Supply & installation of outdoor light fittings on buildings

260 Supply, conveyance, installation, testing and commissioning of


pre-wired fluorescent fitting of the following types complete with
all accessories and fluorescent lamps etc. in the existing GI pipe
and giving connections with required length of 16/0.20mm 3 core
copper conductor flex wire conforming to relevant ISS or
extending the original wiring and giving connection etc. as
required.

A Fluorescent street light fitting with aluminium housing, stove


enameled CRCA sheet steel reflector cover, acrylic cover
complete with lamp holder, APF electronic ballast suitable for
continuous operation with THD <10%, power factor >0.98, RoHS
compliant, duly wired up for use on 230 V AC supply.

a1 Suitable for single 28 W T5 lamp E 1677.00


a2 Suitable for twin 28 W T5 lamp E 2292.00
a3 Suitable for 4 Nos 14 W T5 lamps E 6772.00
a4 Suitable for 4 Nos 24 W T5 lamps E 6795.00
B Fluorescent street light fitting with aluminium housing, stove
enameled CRCA sheet steel reflector cover, acrylic cover
complete with lamp holder, electronic ballast suitable for
continuous operation with THD <10%, duly wired up for use on
230 V AC supply

b1 Suitable for single 28 W T5 lamp E 1392.00


b2 Suitable for twin 28 W T5 lamp E 1801.00
b3 Suitable for 4 Nos 14 W T5 lamps E 6118.00
b4 Suitable for 4 Nos 24 W T5 lamps E 6141.00
C Fluorescent street light fitting with FRP housing, stove enameled
CRCA sheet steel reflector cover, acrylic cover complete with
lamp holder, APF electronic ballast suitable for continuous
operation with THD <10%, power factor >0.98, RoHS compliant,
duly wired up for use on 230 V AC supply

c1 Suitable for 4 Nos 14 W T5 lamps E 6853.00


c2 Suitable for 4 Nos 24 W T5 lamps E 7081.00
D Fluorescent street light fitting with FRP housing, stove enameled
CRCA sheet steel reflector cover, acrylic cover complete with
lamp holder, electronic ballast suitable for continuous operation
with THD <10%, duly wired up for use on 230 V AC supply

d1 Suitable for 4 Nos 14 W T5 lamps E 6199.00


d2 Suitable for 4 Nos 24 W T5 lamps E 6508.00
265 Supply, conveyance, installation, testing and commissioning of
single piece integral luminaire suitable for roadway installation
with die-cast aluminium housing with top opening in powder
coated finish with POT optics reflector, toughened glass cover
(IP 65 protection) control gear and lamp holder suitable for the
following types of lamps pre-wired up to the terminal block
including supply and providing suitable lamps in the existing GI
pipe and giving connections with the extended original wiring
and giving connection etc. as required of the following types and
ratings.
a1 70W SV lamp E 2943.00
a2 150W SV lamp E 4214.00
a3 250W SV lamp E 5093.00
a4 400W SV lamp E 6152.00

b1 70W Metal Halide lamp E 3283.00


b2 150W Metal Halide lamp E 4848.00
b3 250W Metal Halide lamp E 5092.00
b4 400W Metal Halide lamp E 7432.00

c1 70W CDMT lamp E 4697.00


c2 150W CDMT lamp E 5850.00
c3 250W CDMT lamp E 6132.00
266 Supply, conveyance, installation, testing and commissioning of
single piece integral luminaire suitable for roadway installation
with die-cast aluminium housing with top opening in powder
coated finish with POT optics reflector, toughened glass cover
(IP 66 protection) control gear and lamp holder suitable for the
following types of lamps pre-wired up to the terminal block
including supply and providing suitable lamps in the existing GI
pipe and giving connections with the extended original wiring
and giving connection etc. as required of the following types and
ratings.
a1 70W SV lamp E 4187.00
a2 150W SV lamp E 4885.00
a3 250W SV lamp E 7045.00
a4 400W SV lamp E 8605.00

b1 250W Metal Halide lamp E 9350.00


b2 400W Metal Halide lamp E 9159.00

c1 150W CDMT lamp E 6603.00


c2 250W CDMT lamp E 10685.00

PART IV
SH: CARRIAGE AND ERECTION OF FAN
300 Supply and installation of suitable size MS rod type fan clamp as
per IS 732 as required. E 92.50
301 Supply and installation of suitable size MS belt type fan clamp
fabricated from MS flat (2 pieces) as per IS 732 as required.
E 140.00
302 Conveyance installation testing and commissioning ceiling fan of
all sizes using standard accessories including resistance type
regulator, wiring the down rod with 16/0.20mm PVC insulated
and PVC sheathed 650/1100V grade 3 core round copper
conductor flex wire or extending the original wiring etc. as
required.
E 91.00
303 Conveyance installation testing and commissioning ceiling fan of
all sizes using standard accessories excluding resistance type
regulator, wiring the down rod with 16/0.20mm PVC insulated
and PVC sheathed 650/1100V grade 3 core round copper
conductor flex wire or extending the original wiring etc. as
required.
E 88.00
304 Conveyance , installation , testing and commissioning of ceiling
fans of all sizes on suitable size HG 300mm long GI/ WI pipe
including cutting, threading, drilling and painting the rod, wiring
the down rod with required length of 16/0.20mm PVC insulated
and PVC sheathed 650/1100V grade 3 core copper conductor
flex wire or with the original wiring extended including supply of
down rod excluding shackle insulator and suspension
arrangements as required.
E 133.00
305 Supply and providing every additional length of down rod of
suitable size heavy gauge GI / WI pipe with 16/0.20mm PVC
insulated and PVC sheathed 3 core round copper conductor flex
wire conforming in relevant ISS or with original wiring extended
including painting as required.
m 91.00
306 Extra for cutting threading and drilling of GI/WI pipe heavy
gauge down rod for ceiling fan etc. as required (for reducing the E 21.00
rod length)
307 Supply, conveyance, installation, testing and commissioning of
ceiling fans of the following sizes using standard accessories
including resistance type regulator, wiring the down rod with
16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3
core round copper conductor flex wire or with extended original
wiring etc. as required.
a1 900 mm sweep (Category A) E 1275.00
b1 1200 mm sweep (Category A) E 1285.00
c1 1400 mm sweep (Category A) E 1370.00
a2 900 mm sweep (Category B) E 1611.00
b2 1200 mm sweep (Category B) E 1656.00
c2 1400 mm sweep (Category B) E 1771.00
308 Supply, conveyance, installation, testing and commissioning of
ceiling fans of the following sizes using standard accessories
excluding resistance type regulator, wiring the down rod with
16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3
core round copper conductor flex wire or with extended original
wiring etc. as required.
a1 900 mm sweep (Category A) E 1217.00
b1 1200 mm sweep (Category A) E 1227.00
c1 1400 mm sweep (Category A) E 1312.00
a2 900 mm sweep (Category B) E 1554.00
b2 1200 mm sweep (Category B) E 1598.00
c2 1200 mm sweep (Category B)- 5 star rated E 1752.00
d2 1400 mm sweep (Category B) E 1713.00
310 Conveyance, installation, testing and commissioning wall
mounting fan of all sizes using mounting brackets supplied along
with the fan and giving connection with existing wire. E 61.00
311 Supply, conveyance, installation, testing and commissioning wall
mounting fan of the following sizes using mounting brackets
supplied along with the fan and giving connection with existing
wire.

a 300 mm sweep E 1536.00


b 400 mm sweep E 1693.00
312 Charges for cutting holes suitable for accommodating exhaust
fans of sizes up to 305 mm sweep including plastering, colour
washing etc. as required. E 196.00
313 Charges for cutting holes suitable for accommodating exhaust
fans of sizes exceeding 305 mm sweep up to 450 mm including
plastering, colour washing etc. as required.
E 265.00
314 Conveyance, installation, testing and commissioning of exhaust
fans of size up to 450 mm in the existing opening, fixing
necessary bolt and nuts, making good the damages etc. as
required including giving connections with required length of
24/0.20mm PVC insulated and PVC sheathed 3 core round
copper conductor flex wire conforming to relevant ISS.

E 206.00
315 Supply, conveyance, installation, testing and commissioning of
the following sizes of exhaust fans in the existing opening, fixing
necessary bolt and nuts, making good the damages etc. as
required including giving connections with required length of
24/0.20mm PVC insulated and PVC sheathed 3 core round
copper conductor flex wire conforming to relevant ISS.

a1 150 mm, single phase, light duty exhaust fan in plastic body with
self opening louvers E 1301.00
a2 200 mm, single phase, light duty exhaust fan in plastic body with
self opening louvers E 1414.00
a3 250 mm, single phase, light duty exhaust fan in plastic body with
self opening louvers E 1473.00
a4 225 mm, single phase light duty exhaust fan in metal frame
(Group A) E 1261.00
a5 225 mm, single phase light duty exhaust fan in metal frame
(Group B) E 1561.00
a6 300/ 305 mm, single phase light duty exhaust fan in metal frame
(Group A) E 1333.00
a7 300/ 305 mm, single phase light duty exhaust fan in metal frame
(Group B) E 1672.00
a8 305 mm, single phase, heavy duty, 900 rpm exhaust fan in metal
frame E 2506.00
a9 305 mm, single phase, heavy duty, 1400 rpm exhaust fan in metal
frame E 2506.00
a10 380 mm, single phase, heavy duty, 900 rpm exhaust fan in metal E 2980.00
a11 frame
380 mm, single phase, heavy duty, 1400 rpm exhaust fan in metal E 3024.00
a12 frame
450 mm, single phase, heavy duty, 900 rpm exhaust fan in metal E 3674.00
a13 frame
450 mm, single phase, heavy duty, 1400 rpm exhaust fan in metal E 4042.00
frame PART V
SH: ERECTION OF CALL BELL
320 Supply and fixing the following types of superior quality 250V
A.C call bell on existing M.S. box and giving connections with
required length of 3 core, 16 / 0.20mm 650/1100V grade PVC
insulated and PVC sheathed round copper conductor flex wire
conforming to relevant ISS or with the extended original wiring,
earthing the MS box and making good the surface as required.

a Buzzer E 60.00
b Call bell E 70.00
c Ding Dong bell E 109.00
d Musical bell with bird sound E 140.00
e Musical bell with multiple tunes E 192.00
f DC operated remote controlled bell E 575.00
g Gong bell - 75 mm - without MS box E 519.00
h Gong bell - 100 mm - without MS box E 617.00
i Gong bell - 150 mm - without MS box E 715.00
j Gong bell - 225 mm - without MS box E 1106.00
k Gong bell - 300 mm - without MS box E 1314.00
l Bell indicator Way 197.00
PART VI
SH: SUB MAIN WIRING
330 Supply and fixing the following sizes of PVC Conduit
conforming to IS 9537 / 1983 part III along with all required
accessories on surface including making good the damages etc as
required.

a1 20 mm dia light gauge m 59.00


a2 25 mm dia light gauge m 70.00
a3 32 mm dia light gauge m 89.00
a4 40 mm dia light gauge m 130.00
a5 50 mm dia light gauge m 180.00

b1 20 mm dia medium gauge m 63.00


b2 25 mm dia medium gauge m 73.00
b3 32 mm dia medium gauge m 98.00
b4 40 mm dia medium gauge m 139.00
b5 50 mm dia medium gauge m 188.00

c1 20 mm dia heavy gauge m 70.00


c2 25 mm dia heavy gauge m 83.00
c3 32 mm dia heavy gauge m 112.00
c4 40 mm dia heavy gauge m 149.00
c5 50 mm dia heavy gauge m 207.00
331 Supply and fixing the following sizes of PVC Conduit
conforming to IS 9537 / 1983 part III along with all required
accessories in recess including cutting the wall and making good
the damages etc as required.
a1 20 mm dia light gauge m 83.00
a2 25 mm dia light gauge m 94.00
a3 32 mm dia light gauge m 115.00
a4 40 mm dia light gauge m 157.00
a5 50 mm dia light gauge m 205.00

b1 20 mm dia medium gauge m 87.00


b2 25 mm dia medium gauge m 97.00
b3 32 mm dia medium gauge m 124.00
b4 40 mm dia medium gauge m 166.00
b5 50 mm dia medium gauge m 213.00

c1 20 mm dia heavy gauge m 94.00


c2 25 mm dia heavy gauge m 107.00
c3 32 mm dia heavy gauge m 138.00
c4 40 mm dia heavy gauge m 176.00
c5 50 mm dia heavy gauge m 232.00
332 Supply and fixing the following sizes of PVC Oval Conduit along
with all required accessories in surface / recess including cutting
the wall and making good the damages in case of recessed
conduit as required.
a 16 mm dia m 50.00
b 20 mm dia m 54.00
c 25 mm dia m 63.00
333 Supplying and clamping the following sizes of corrugated PVC
flexible conduit with necessary compression gland with locking
ring and check nut at termination pointed using suitable size GI /
painted MS saddles spacing not exceeding 60 cms on surface
including making good the damages, colour washing etc. as
required.

a 10 mm dia m 35.00
a 16 mm dia m 36.00
b 20 mm dia m 40.00
c 25 mm dia m 50.00
d 32 mm dia m 67.00
e 40 mm dia m 80.00
f 50 mm dia m 112.00
334 Supply and fixing the following sizes of heavy duty best quality
16 gauge (1.63 mm) black stove enameled (both inside and
outside) M.S. conduit with inspection type specials conforming to
IS 3837 in surface/ recess using suitable size GI/ painted M.S.
saddles spacing not exceeding 60 cams including making good
the damages colour washing etc. as required.

a 20 mm dia m 135.00
b 25 mm dia m 160.00
c 32 mm dia m 151.00
Supply & drawing copper wires
340 Supply and drawing 650/1100 V grade PVC insulated stranded
single core copper conductor cables conforming to IS 694 part I
1990 in the existing surface / recess conduit as required including
giving necessary connections of the following sizes.

a1 1.00 sq mm 1 run m 34.50


a2 1.00 sq mm 2 run m 45.00
a3 1.00 sq mm 3 run m 55.00
a4 1.00 sq mm 4 run m 66.00
a5 1.00 sq mm 5 run m 76.00
a6 1.00 sq mm 6 run m 87.00
a7 1.00 sq mm 7 run m 97.00
a8 1.00 sq mm 8 run m 108.00
a9 1.00 sq mm 9 run m 118.00
a10 1.00 sq mm 10 run m 129.00

b1 1.50 sq mm 1 run m 40.00


b2 1.50 sq mm 2 run m 55.00
b3 1.50 sq mm 3 run m 71.00
b4 1.50 sq mm 4 run m 87.00
b5 1.50 sq mm 5 run m 102.00
b6 1.50 sq mm 6 run m 118.00
b7 1.50 sq mm 7 run m 134.00
b8 1.50 sq mm 8 run m 149.00
b9 1.50 sq mm 9 run m 165.00
b10 1.50 sq mm 10 run m 181.00

c1 2.50 sq mm 1 run m 49.00


c2 2.50 sq mm 2 run m 74.00
c3 2.50 sq mm 3 run m 98.00
c4 2.50 sq mm 4 run m 123.00
c5 2.50 sq mm 5 run m 148.00
c6 2.50 sq mm 6 run m 173.00
c7 2.50 sq mm 7 run m 197.00
c8 2.50 sq mm 8 run m 22.00
c9 2.50 sq mm 9 run m 247.00
c10 2.50 sq mm 10 run m 272.00

d1 4.00 sq mm 1 run m 61.00


d2 4.00 sq mm 2 run m 98.00
d3 4.00 sq mm 3 run m 135.00
d4 4.00 sq mm 4 run m 172.00
d5 4.00 sq mm 5 run m 209.00
d6 4.00 sq mm 6 run m 246.00
d7 4.00 sq mm 7 run m 283.00
d8 4.00 sq mm 8 run m 320.00
d9 4.00 sq mm 9 run m 357.00
d10 4.00 sq mm 10 run m 393.00

e1 6.00 sq mm 1 run m 82.00


e2 6.00 sq mm 2 run m 140.00
e3 6.00 sq mm 3 run m 198.00
e4 6.00 sq mm 4 run m 255.00
e5 6.00 sq mm 5 run m 313.00
e6 6.00 sq mm 6 run m 371.00
e7 6.00 sq mm 7 run m 430.00
e8 6.00 sq mm 8 run m 488.00
e9 6.00 sq mm 9 run m 546.00
e10 6.00 sq mm 10 run m 604.00

f1 10.00 sq mm 1 run m 120.00


f2 10.00 sq mm 2 run m 217.00
f3 10.00 sq mm 3 run m 313.00
f4 10.00 sq mm 4 run m 409.00
f5 10.00 sq mm 5 run m 506.00
f6 10.00 sq mm 6 run m 602.00
f7 10.00 sq mm 7 run m 700.00
f8 10.00 sq mm 8 run m 796.00
f9 10.00 sq mm 9 run m 892.00
f10 10.00 sq mm 10 run m 989.00
g1 16.00 sq mm 2 run m 329.00
g2 16.00 sq mm 3 run m 481.00
g3 16.00 sq mm 4 run m 653.00
g4 16.00 sq mm 6 run m 938.00

h1 25 sq. mm. 2 run m 513.00


h2 25 sq. mm. 3 run m 757.00
h3 25 sq. mm. 4 run m 1001.00
h4 25 sq. mm. 6 run m 1489.00

i1 35 sq. mm. 2 run m 668.00


i2 35 sq. mm. 3 run m 990.00
i3 35 sq. mm. 4 run m 1312.00
i4 35 sq. mm. 6 run m 1957.00

j1 50 sq. mm. 2 run m 958.00


j2 50 sq. mm. 3 run m 1425.00
j3 50 sq. mm. 4 run m 1892.00
j4 50 sq. mm. 6 run m 2826.00
341 Supply and drawing the following sizes of multi-core PVC
insulated & PVC sheathed 650/1100 V grade copper conductor
round flexible cables conforming to IS 694 part I 1960 in the
existing surface / recess conduit as required including giving
necessary connections of the following sizes.

a1 2 core 0.50 sq. mm. m 33.00


a2 2 core 0.75 sq. mm. m 38.00
a3 2 core 1.00 sq. mm. m 43.00
a4 2 core 1.50 sq. mm. m 53.00
a5 2 core 2.50 sq. mm. m 75.00
a6 2 core 4.00 sq. mm. m 106.00
a7 2 core 6.00 sq. mm. m 165.00
a8 2 core 10.00 sq. mm. m 260.00

b1 3 core 0.50 sq. mm. m 38.00


b2 3 core 0.75 sq. mm. m 45.00
b3 3 core 1.00 sq. mm. m 52.00
b4 3 core 1.50 sq. mm. m 65.00
b5 3 core 2.50 sq. mm. m 98.00
b6 3 core 4.00 sq. mm. m 140.00
b7 3 core 6.00 sq. mm. m 208.00
b8 3 core 10.00 sq. mm. m 342.00

c1 4 core 0.50 sq. mm. m 44.00


c2 4 core 0.75 sq. mm. m 54.00
c3 4 core 1.00 sq. mm. m 64.00
c4 4 core 1.50 sq. mm. m 82.00
c5 4 core 2.50 sq. mm. m 124.00
c6 4 core 4.00 sq. mm. m 179.00
c7 4 core 6.00 sq. mm. m 271.00
c8 4 core 10.00 sq. mm. m 444.00
342 Supply and drawing PVC insulated & sheathed 650/1100 V grade
3 core copper conductor flat cable for submersible pump motor
conforming to IS 694 part I 1990 as required including giving
necessary connections of the following sizes.

a 1.50 sq. mm m 64.00


b 2.50 sq. mm m 92.00
c 4.00 sq. mm m 136.00
d 6.00 sq. mm m 197.00
e 10.00 sq. mm. m 323.00
f 16.00 sq. mm. m 515.00
g 25.00 sq. mm. m 840.00
h 35.00 sq. mm. m 1197.00
i 50.00 sq. mm. m 1611.00
343 Supplying & Drawing the following types of UTP Cable
conforming to relevant standards through the existing conduit and
giving connections as required
a Cat 5E UTP Cable m 31.00
b Cat 6 UTP Cable m 44.00
344 Supplying & Drawing the following types of T.V Co-axial Cable
conforming to relevant standards through the existing conduit

a RG 59 cable m 33.00
b RG 11 cable m 37.00
c RG 6 cable m 60.00
345 Supplying & Drawing unarmored PVC insulated and & PVC
sheathed copper conductor Telephone Pair Cable conforming to
ITD specification for indoor application through the existing
conduit

a 1 Pair m 19.00
b 2 Pair m 25.00
c 3 Pair m 29.00
d 4 Pair m 35.00
e 5 Pair m 40.00
f 6 Pair m 46.00
g 8 Pair m 55.00
h 10 Pair m 64.00
i 20 Pair m 116.00
j 50 Pair m 275.00
PART VII
SH: S& F MS BOXES
350 Supplying and fixing the following sizes of M.S. Boxes made out
of 1.60 mm thick sheet painted grey (both inside and outside ) in
surface/ recess including phenolic laminated sheet covers of
thicknesses noted along with screwed to the box as front cover
with steel screws, cup washers etc. making good the surface,
painting /colour washing etc. as required.

50 mm deep
a1 75 mm x 75 mm x 50 mm with 3 mm sheet E 127.00
a2 100 mm x 100 mm x 50mm with 3 mm sheet E 141.00
a3 100 mm x 125 mm x 50mm with 3 mm sheet E 153.00
a4 125 mm x 150 mm x 50mm with 3 mm sheet E 170.00
a5 125 mm x 200 mm x 50mm with 3 mm sheet E 203.00
a6 125 mm x 250 mm x 50 mm with 3 mm sheet E 227.00
a7 125 mm x 300 mm x 50 mm with 3 mm sheet E 254.00
a8 150 mm x 150 mm x 50 mm with 3 mm sheet E 198.00
a9 150 mm x 200 mm x 50 mm with 3 mm sheet E 237.00
a10 200 mm x 250 mm x 50 mm with 3 mm sheet E 312.00
a11 200 mm x 300 mm x 50 mm with 3 mm sheet E 350.00
a12 250 mm x 300 mm x 50 mm with 3 mm sheet E 400.00
a13 250 mm x 375 mm x 50 mm with 6mm sheet E 527.00
a14 250 mm x 500 mm x 50 mm with 6mm sheet E 659.00
a15 300 mm x 300 mm x 50 mm with 6mm sheet E 511.00
a16 300 mm x 600 mm x 50 mm with 6mm sheet E 882.00
a17 375 mm x 375 mm x 50 mm with 6mm sheet E 706.00
a18 375 mm x 500 mm x 50 mm with 6mm sheet E 902.00
a19 375 mm x 600 mm x 50 mm with 6mm sheet E 1047.00
a20 500 mm x 600 mm x 50 mm with 6mm sheet E 1323.00
75 mm deep
b1 75 mm x 75 mm x 75 mm with 3 mm sheet E 143.00
b2 100 mm x 100 mm x 75mm with 3 mm sheet E 160.00
b3 100 mm x 125 mm x 75mm with 3 mm sheet E 176.00
b4 125 mm x 150 mm x 75mm with 3 mm sheet E 197.00
b5 125 mm x 200 mm x 75mm with 3 mm sheet E 234.00
b6 125 mm x 250 mm x 75 mm with 3 mm sheet E 265.00
b7 125 mm x 300 mm x 75 mm with 3 mm sheet E 297.00
b8 150 mm x 150 mm x 75 mm with 3 mm sheet E 229.00
b9 150 mm x 200 mm x 75 mm with 3 mm sheet E 274.00
b10 200 mm x 250 mm x 75 mm with 3 mm sheet E 360.00
b11 200 mm x 300 mm x 75 mm with 3 mm sheet E 404.00
b12 250 mm x 300 mm x 75 mm with 3 mm sheet E 459.00
b13 250 mm x 375 mm x 75 mm with 6mm sheet E 595.00
b14 250 mm x 500 mm x 75 mm with 6mm sheet E 740.00
b15 300 mm x 300 mm x 75 mm with 6mm sheet E 577.00
b16 300 mm x 600 mm x 75 mm with 6mm sheet E 978.00
b17 375 mm x 375 mm x 75 mm with 6mm sheet E 787.00
b18 375 mm x 500 mm x 75 mm with 6mm sheet E 997.00
b19 375 mm x 600 mm x 75 mm with 6mm sheet E 1152.00
b20 500 mm x 600 mm x 75 mm with 6mm sheet E 1440.00
100 mm deep
c1 75 mm x 75 mm x 100 mm with 3 mm sheet E 158.00
c2 100 mm x 100 mm x 100mm with 3 mm sheet E 181.00
c3 100 mm x 125 mm x 100mm with 3 mm sheet E 199.00
c4 125 mm x 150 mm x 100mm with 3 mm sheet E 223.00
c5 125 mm x 200 mm x 100mm with 3 mm sheet E 267.00
c6 125 mm x 250 mm x 100 mm with 3 mm sheet E 301.00
c7 125 mm x 300 mm x 100 mm with 3 mm sheet E 338.00
c8 150 mm x 150 mm x 100 mm with 3 mm sheet E 261.00
c9 150 mm x 200 mm x 100 mm with 3 mm sheet E 310.00
c10 200 mm x 250 mm x 100 mm with 3 mm sheet E 408.00
c11 200 mm x 300 mm x 100 mm with 3 mm sheet E 461.00
c12 250 mm x 300 mm x 100 mm with 3 mm sheet E 517.00
c13 250 mm x 375 mm x 100 mm with 6mm sheet E 662.00
c14 250 mm x 500 mm x 100 mm with 6mm sheet E 820.00
c15 300 mm x 300 mm x 100 mm with 6mm sheet E 642.00
c16 300 mm x 600 mm x 100 mm with 6mm sheet E 1075.00
c17 375 mm x 375 mm x 100 mm with 6mm sheet E 867.00
c18 375 mm x 500 mm x 100 mm with 6mm sheet E 1094.00
c19 375 mm x 600 mm x 100 mm with 6mm sheet E 1257.00
c20 500 mm x 600 mm x 100 mm with 6mm sheet E 1558.00
PART VIII
SH: S& F PIANO TYPE ACCESSORIES
360 Supplying and fixing the following piano type accessories in the
phenolic laminated front cover of existing MS box including
providing necessary holes and giving connections etc. as
required.

a1 6A 1 way switch E 34.00


a2 6A 2 way switch E 36.50
a3 16A 1 way switch E 74.50
a4 16A 1 way switch with Neon E 90.50
a5 16A 2 way switch E 84.00
b1 6A bell push E 36.00
b2 Neon Indicator E 36.00

c1 6A 2 Pin socket E 34.00


c2 6A 2 Pin socket suitable for English Pin E 39.00
c3 6 A 3 pin socket E 39.50
c4 6 A 5 pin socket E 41.00
c5 6 A 5 pin socket suiting English pin ( round & square) also E 46.00
c6 16 A 3 pin socket E 73.00
c7 6/13 A international socket E 60.00
c8 6/16 A universal socket E 76.00

d1 6 A 3 pin switch socket combined flush type E 65.00


d2 16 A 3 pin switch socket combined flush type E 105.00
d3 6/16 A switch socket combined flush type E 107.00
d4 6/16 A switch socket combined flush type with neon E 118.00

e1 6 A 3 pin plug top E 31.00


e2 16 A 3 pin plug top E 47.00
e3 16 A 3 pin plug top with fuse E 49.00
e4 6 A 3 pin plug top unbreakable (polycarbonate) E 38.00
e5 16 A 3 pin plug top unbreakable (polycarbonate) E 53.00

f1 2 Plate ceiling rose E 35.00


f2 3 Plate ceiling rose E 36.00

g1 3 pin telephone socket E 36.00


g2 3 pin telephone top E 34.00
g3 RJ 11 telephone jack (2 lines) E 61.00
g4 RJ 11 telephone jack (4 lines) E 71.00
g5 RJ 11 telephone jack (2 lines) with shutter E 54.00

h1 TV antenna socket – switch size E 42.50


h2 TV antenna socket – size E 46.00

i1 Step fan regulator – switch size E 220.00


i2 Step fan regulator – socket size E 237.00
PVC gang box E
361 Supplying and fixing the following sizes of PVC gang box in
surface/ recess making good the surface, painting /colour
washing etc. as required.
a PVC Gang box 1 way E 21.00
b PVC Gang box 2 way E 24.50
Industrial plug & socket
362 Supply and fixing SP & N metal case enclosure with 2 pole and
earth plug socket with pin suitable for incorporating , SP MCB
(excluding cost of SP MCB) in surface/ recess including giving
necessary connections, making good the damages etc. as required.

a 250V, 10A, 2 pole and earth E 752.00


b 250V, 20A, 2 pole and earth E 777.00
PART IX
SH: S& F CABLE MANAGEMENT SYSTEM
PVC Cable management system - 50 x 50 mm & 100 x 50 mm

370 Supply and fixing 50 x 50 mm PVC Cable Management System


with base and lid along with the following accessories
conforming to IEC 61084/ BS 476 & 4678 on surface / recess
including cutting the wall and making good the damages in case
of recessed installation as required.

a 50 x 50 mm CMS with base & lid m 354.00


b External Angle 90° E 94.00
c Flat Angle 90° E 87.50
d Internal Angle 90° E 91.00
e Internal Coupler E 65.50
f Flat cross E 291.00
g End Cap E 62.50
h Flanged Coupler E 99.00
i Joint cover E 46.50
j Special Internal angle 45° E 161.00
k Special External angle 45° E 161.00
l Special Flat angle 45° E 161.00
m External Tee E 160.00
n Flat Tee E 87.50
p Internal Tee E 160.00
q Cable Retainer E 37.50
r Wall plate for internal angle E 62.50
371 Supply and fixing 100 x 50 mm PVC Cable Management System
with base and lid along with the following accessories
conforming to IEC 61084/ BS 476 & 4678 on surface / recess
including cutting the wall and making good the damages in case
of recessed installation as required.

a 100 x 50 mm CMS with base & lid m 623.00


b Cable divider E 78.00
c External Angle 90° E 100.00
d Flat Angle 90° E 90.00
e Internal Angle 90° E 91.00
f Internal Coupler E 56.00
g Flat cross E 302.00
h End Cap E 65.50
i Flanged Coupler E 124.00
j Joint cover E 68.50
k Special Internal angle 45° E 302.00
l Special External angle 45° E 208.00
m Special Flat angle 45° E 208.00
n External Tee E 302.00
p Flat Tee E 83.00
q Internal Tee E 302.00
r Cable Retainer E 31.00
s 1 to 3 module mounting box E 101.00
t 4 to 5 module mounting box E 116.00
u Spacer box E 27.50
v 3 / 5 module under box divider E 28.00
w Wall plate for internal angle E 62.50
x Mini Trunking adapter E 30.50
y MCB/RCD Housing E 220.00
z Reducer 100 x 50 to 50 x 50 mm E 173.00
PART X
SH: SUPPLY & FIXING MODULAR ACCESSORIES
(GROUP - A)
Group A modular accessories - S & F boxes
380 Supply & Fixing the following types/ sizes of boxes suitable for
modular accessories in surface/ recess including making good the
damages, colour washing etc as required ( Group A)

a1 1 module moulded plastic box in recess E 83.00


a2 2 module moulded plastic box in recess E 83.00
a3 3 module moulded plastic box in recess E 88.00
a4 4 module moulded plastic box in recess E 94.00
a5 5 module moulded plastic box in recess E 107.00
a6 6 module moulded plastic box in recess E 112.00
a7 8 module moulded plastic box in recess E 130.00
a8 10 module moulded plastic box in recess E 149.00
a9 12 module moulded plastic box in recess E 155.00
a10 16 module moulded plastic box in recess E 166.00
a11 18 module moulded plastic box in recess E 181.00

b1 1 module moulded plastic box on surface E 101.00


b2 2 module moulded plastic box on surface E 101.00
b3 3 module moulded plastic box on surface E 107.00
b4 4 module moulded plastic box on surface E 107.00
b5 5 module moulded plastic box on surface E 111.00
b6 6 module moulded plastic box on surface E 123.00
b7 8 module moulded plastic box on surface E 151.00
b8 9 module moulded plastic box on surface E 165.00
b9 10 module moulded plastic box on surface E 147.00
b10 12 module moulded plastic box on surface E 173.00
b11 16 module moulded plastic box on surface E 166.00
b12 18 module moulded plastic box on surface E 184.00

c1 1 module metal box in recess E 94.00


c2 2 module metal box in recess E 94.00
c3 3 module metal box in recess E 101.00
c4 4 module metal box in recess E 110.00
c5 5 module metal box in recess E 116.00
c6 6 module metal box in recess E 136.00
c7 8 module metal box in recess E 159.00
c8 9 module metal box in recess E 170.00
c9 10 module metal box in recess E 174.00
c10 12 module metal box in recess E 193.00
c11 16 module metal box in recess E 183.00
c12 18 module metal box in recess E 223.00

d1 12 module metal box on surface E 310.00


d2 18 module metal box on surface E 320.00
Group A modular accessories - S & F front plates
381 Supply & Fixing the following types/ sizes of front plates on the
existing modular boxes. (Group A)
a1 1 module white E 49.00
a2 2 module white E 51.00
a3 3 module white E 61.00
a4 4 module white E 68.00
a5 5 module white E 69.00
a6 6 module white E 94.00
a7 8 module white E 118.00
a8 9 module white E 113.00
a9 10 module white E 112.00
a10 12 module white E 142.00
a11 16 module white E 128.00
a12 18 module white E 177.00
Group A modular accessories - S & F accessories
382 Supply and Fixing the following modular switches & accessories
in the existing front plates and giving necessary connections as
required (Group A)
a1 6 A SP 1 way switch E 52.00
a2 6 A SP 2 way switch E 62.00
a3 6 A SP 1 way switch with indicator E 65.00
a4 6 A SP 2 way switch with indicator E 76.00

b1 6 A SP 1 way bell push E 61.00


b2 6 A SP 1 way bell push with indicator E 80.00
b3 16 A SP 1 way bell push E 86.00
b4 16 A SP 1 way bell push with indicator E 106.00

c1 16 A SP 1 way switch E 74.00


c2 16 A SP 2 way switch E 84.00
c3 16 A SP 1 way switch with indicator E 83.00
E
d1 20 A DP switch with indicator E 122.00
d2 32 A DP switch with indicator E 129.00

e1 6 A to 32 A modular type SP MCB E 102.00


e2 6 A to 32 A modular type DP MCB E 240.00

f1 32 A DP Load break switches ( Isolators) E 218.00


f2 50 A DP Load break switches ( Isolators) E 237.00

g1 Heavy duty plug and socket unit for flush mounting comprising
of appropriately rated SP MCB, 25 A socket and 25 A plug top
with indicator along with mounting plate E 376.00
g2 Heavy duty plug and socket unit for flush mounting comprising
of appropriately rated SP MCB, 25 A socket and 25 A plug top
with indicator along with mounting plate and plastic mounting
box.
E 415.00

h1 Single phase Motor starter (16 A with current setting of 0.6 – 1 A


for 1/8 HP motor, 0.9 – 1.5 A for 1/4 HP motor, 1.2 – 2 A for 1/3
HP motor, 2.0 -2.5 A for 1/2 HP motor, 3.0 – 5 A for 3/4 HP
motor, 4.75 – 7.5 A for 1 TR A/C, 7 – 11 A for 1.5 TR A/C )

E 277.00
h2 Single phase Motor starter (20 A with current setting of 11A to
18 A for 2 Ton A/C) E 287.00
h3 Single phase Motor starter (25 A with current setting of 16A to
25 A for 2.5 Ton A/C) E 309.00

i1 A/C Power units flush type with suitably rated MCB and suitably
rated motor starter along with 25 A illuminated plug and socket
with front plate etc., suitable for 1.5 TR A/C, 2TR A/C or 2.5 TR
A/C
E 777.00
i2 A/C Power units flush type with suitably rated MCB and suitably
rated motor starter along with 25 A illuminated plug and socket
with front plate etc., suitable for 1.5 TR A/C, 2TR A/C or 2.5 TR
A/C but without MCB
E 528.00
i3 A/C Power units box type with suitably rated MCB and suitably
rated motor starter along with 25 A illuminated plug and socket
with front plate, mounting box etc., for direct fitting to wall
suitable for 1.5 TR A/C, 2TR A/C or 2.5 TR A/C

E 856.00
i4 Complete unit of 20 A Starter unit and 25 A socket with 4 module
plate and surface box for 4 HP motor. E 484.00
i5 Complete unit of 20 A Starter unit and 25 A socket with 4 module
plate and surface box for 4 HP motor but without MCB
E 597.00

j1 6 A charger socket 2 module for mobile charger, lap top E 55.00


j2 6 A Universal socket E 112.00
j3 6 A, 2 / 3 pin socket E 75.00
j4 6 / 16 A combined socket E 109.00
j5 13 A 3 pin socket suitable for flat pin E 121.00
j6 6 / 10 / 13 A international sockets for all pins E 120.00
j7 25 A Universal socket E 128.00
j8 Shaver socket E 204.00

k1 RJ 11 Telephone Jack E 65.00


k2 2 Line RJ 11 Telephone Jack E 88.00
k3 CAT 6 RJ 45 Computer Jack E 338.00
k4 CAT 5E RJ 45 Computer Jack E 280.00

l1 6 A 3 pin plug top E 30.00


l2 6 A 3 pin plug top with indicator E 38.00
l3 16 A 3 pin plug top E 35.00
l4 16 A 3 pin plug top with indicator E 55.00
l5 25 A 3 pin plug top with indicator E 64.00

m1 Buzzer E 74.00
m2 Electronic buzzer - 1M E 98.00
m3 Electronic buzzer - 2M E 120.00
m4 Bulbul Bell 2 module E 131.00

n1 TV Coaxial Socket outlet – 1M E 65.00


n2 Flex out let / chord out let – 1M E 51.00

p1 16A fuse unit – 1M E 62.00


p2 Neon Indicator – red 1M E 43.00
p3 Neon Indicator – Orange 1M E 43.00
p4 Neon Indicator – Amber 1M E 39.00
p5 Neon Indicator – Green 1M E 39.00

q1 100 W step regulator- type 1 M E 253.00


q2 100 W step regulator- type 2 M E 289.00

r1 32 A DP mains on off with key tag E 2087.00


r2 Key tag with key ring E 50.00
r3 3 way neutral link for modular boxes E 62.00

s1 Blank plate 1 M E 12.00


s2 Blank plate 2 M E 25.00
s3 Blank plate 4 M E 21.00
PART XI
SH: SUPPLY & FIXING MODULAR ACCESSORIES
(GROUP B)
Group B modular accessories - S & F boxes
385 Supply & Fixing the following types/ sizes of boxes suitable for
modular accessories in surface/ recess including making good the
damages, colour washing etc as required (Group B)

a1 1 module moulded plastic box in recess E 94.00


a2 2 module moulded plastic box in recess E 94.00
a3 3 module moulded plastic box in recess E 96.00
a4 4 module moulded plastic box in recess E 105.00
a5 6 module moulded plastic box in recess E 124.00
a6 8 module moulded plastic box in recess E 146.00
a7 9 module moulded plastic box in recess E 146.00
a8 12 module moulded plastic box in recess E 176.00
a9 18 module moulded plastic box in recess E 203.00

b1 1 module moulded plastic box on surface E 120.00


b2 2 module moulded plastic box on surface E 120.00
b3 3 module moulded plastic box on surface E 126.00
b4 4 module moulded plastic box on surface E 144.00
b5 5 module moulded plastic box on surface E 172.00
b6 6 module moulded plastic box on surface E 153.00
b7 8 module moulded plastic box on surface E 178.00
b8 9 module moulded plastic box on surface E 152.00
b9 10 module moulded plastic box on surface E 231.00
b10 12 module moulded plastic box on surface E 193.00
b11 16 module moulded plastic box on surface E 191.00

c1 1 module metal box in recess E 101.00


c2 2 module metal box in recess E 101.00
c3 3 module metal box in recess E 106.00
c4 4 module metal box in recess E 115.00
c5 5 module metal box in recess E 118.00
c6 6 module metal box in recess E 146.00
c7 8 module metal box in recess E 166.00
c8 9 module metal box in recess E 185.00
c9 10 module metal box in recess E 182.00
c10 12 module metal box in recess E 226.00
c11 16 module metal box in recess E 209.00
c12 18 module metal box in recess E 250.00
c13 24 module metal box in recess E 246.00

d1 12 module metal box on surface E 310.00


d2 18 module metal box on surface E 322.00
Group B modular accessories - S & F front plates
386 Supply & Fixing the following types/ sizes of front plates on the
existing modular boxes. (Group B)
a1 1 module white/ off-white E 68.00
a2 2 module white/ off-white E 69.00
a3 3 module white/ off-white E 78.00
a4 4 module white/ off-white E 86.00
a5 5 module white/ off-white E 98.00
a6 6 module white/ off-white E 1185.00
a7 8 module white/ off-white E 150.00
a8 9 module white/ off-white E 195.00
a9 10 module white/ off-white E 174.00
a10 12 module white/ off-white E 191.00
a11 16 module white/ off-white E 217.00
a12 18 module white/ off-white E 243.00
a13 24 module white/ off-white E 292.00
b1 1 module metallic gold E 293.00
b2 2 module metallic gold E 302.00
b3 3 module metallic gold E 312.00
b4 4 module metallic gold E 338.00
b5 5 module metallic gold E 347.00
b6 8 module metallic gold E 417.00

c1 1 module metallic (pearl, chroma or brushed steel) E 153.00


c2 2 module metallic (pearl, chroma or brushed steel) E 161.00
c3 3 module metallic (pearl, chroma or brushed steel) E 171.00
c4 4 module metallic (pearl, chroma or brushed steel) E 197.00
c5 5 module metallic (pearl, chroma or brushed steel) E 205.00
c6 8 module metallic (pearl, chroma or brushed steel) E 285.00

Group B modular accessories - S & F Accessories


387 Supply and Fixing the following modular switches & accessories
in the existing front plates and giving necessary connections as
required (Group B)
a1 6 A SP 1 way switch E 81.00
a2 6 A SP 2 way switch E 95.00
a3 6 A SP 1 way switch with indicator E 103.00
a4 6 A SP 2 way switch with indicator E 136.00

b1 6 A SP 1 way bell push E 103.00


b2 10 A SP 1 way bell push E 99.00
b3 10 A SP 1 way bell push with indicator E 105.00
b4 6 A SP 1 way bell push with indicator E 107.00
b5 3 module decorative bell push E 148.00

c1 10 A SP 1 way switch 1 module E 77.00


c2 10 A SP 1 way switch 2 module E 109.00
c3 10 A SP 1 way switch with indicator E 92.00
c4 10 A SP 2 way switch 1 module E 93.00
c5 10 A SP 2 way switch 2 module E 121.00

d1 16 A SP 1 way switch E 119.00


d2 16 A SP 2 way switch E 136.00
d3 16 A SP 2 way switch with indicator E 166.00
d4 16 A SP 1 way switch with indicator E 135.00

e1 20 A SP 1 way switch E 166.00


e2 20 A SP 2 way switch E 264.00
f1 25 A SP 1 way switch E 126.00
f2 20 A DP switch E 173.00
f3 25 A DP switch with indicator E 282.00
f4 20 A DP switch with indicator E 228.00
f5 25 A DP modular MCB E 419.00
f6 32 A DP switch with indicator E 287.00

g1 Motor starter switch (6 A to 10 A) E 294.00


g2 Motor starter switch (9 A to 15 A) E 305.00
g3 Motor starter switch (16 A to 25 A) E 324.00
g4 Motor starter switch (16 A) E 335.00
g5 Motor starter switch (20 A) E 348.00
g6 Motor starter switch (25 A) E 348.00

h1 16A Power unit with 4 module plate, 16A starter, 16A socket and
16 A plug top E 671.00
h2 20A Power unit with 4 module plate, 20A starter, 20A socket and
20 A plug top E 671.00
h3 25A Power unit with 4 module plate, 25A starter, 25A socket and
25 A plug top E 671.00

i1 6 A charger socket 2 module for mobile charger, lap top E 103.00


i2 6A 3 pin shuttered socket E 113.00
i3 6 A Universal socket E 120.00
i4 6 A, 2 / 3 pin shuttered socket E 119.00
i5 6 / 16 A combined shuttered socket E 169.00
i6 13 A 3 pin shuttered socket suitable for flat pin E 187.00
i7 6 / 10 / 13 A international sockets for all pins E 165.00
i8 10 / 25 A 3 pin Socket E 178.00
i9 20 A 3 pin shuttered socket E 186.00
i10 25 A 3 pin shuttered socket E 203.00
i11 Shaver socket, 110 / 230 V AC with transformer - 4 M E 1074.00

j1 RJ 11 Telephone Jack with shutter E 88.50


j2 2 Line RJ 11 Telephone Jack with shutter E 113.00
j3 Twin RJ 11 Telephone Jack E 100.00

k1 CAT 6 RJ 45 Computer Jack E 360.00


k2 CAT 5E RJ 45 Computer Jack E 215.00
k3 RJ 45 Frame E 88.00

l1 6 A 3 pin plug top E 81.00


l2 16 A 3 pin plug top E 122.00
l3 13A 3 pin plug top with fuse E 129.00
l4 25 A 3 pin plug top with indicator E 129.00

m1 Electronic Chime – 2M E 120.00


m2 Buzzer E 139.00

n1 Neon Indicator – red 1M E 68.00


n2 Neon Indicator – Amber 1M E 71.00
n3 Neon Indicator – Green 1M E 71.00

p1 TV Coaxial Socket outlet – 1M E 88.50


p2 TV cable / Flex out let – 1M E 69.50

q1 6A fuse unit – 1M E 106.00


q2 16A fuse unit – 1M E 108.00

r 100 W Step type fan regulator - 2 M E 375.00

s1 Speaker volume control – 2 M E 312.00


s2 Light Control 300W 2 M E 253.00
s3 Light Control 400W 4 M E 413.00
s4 Light Control 1000W 4 M E 532.00

t1 Energy key switch with Tag – 3M E 401.00


t2 Key tag E 76.00
t3 Electronic key tag ( card operated) E 1310.00
t4 16A DP key card switch E 2218.00
t5 Secret Key 16 A 1 way – 1M E 86.00
t6 20 A energy key tag switch with time delay – 3M E 102.00
t7 Hotel key fob switch 20A without key fob E 579.00
t8 Key fob for 20 A key fob switch E 115.00
t9 Key fob switch 100VA with 30 second delay E 2238.00
t10 Key fob for 100VA with 30 second delay switch E 767.00
t11 “Do not disturb” indicator lamp 1 + 1 module E 762.00
t12 Internal control unit for “Do not disturb” indicator lamp 1 + 1
module E 673.00

u1 Pre-wired 10M horizontal plate assembled with 3 Intel Sockets


controlled by 16A Indicator switch E 1024.00
u2 Pre-wired 10M horizontal plate assembled with 3Nos 6 / 16A
Sockets controlled by 16A Indicator switch E 984.00
u3 Pre-wired 10M horizontal plate assembled with 4 Nos 6A Sockets
controlled by 16A Indicator switch E 984.00
v1 6 A SPN MCB 2 module E 2192.00
v2 10 A SPN MCB 2 module E 2192.00
v3 16 A SPN MCB 2 module E 2192.00
v4 16 A, 30 mA SPN RCBO 2 M E 3633.00
v5 16 A 250 V AC voltage surge protector E 3633.00
v6 Replacement module for voltage surge protector E 1827.00

w1 Blank plate 1 M E 18.50


w2 Blank plate 2 M E 29.00
w3 Blank plate 4 M E 24.00

PART XII
SH: SUPPLY & FIXING MCB DBs & ACCESSORIES
S & F Enclosures for MCB DB
390 Supply and installation of sheet steel, phosphatised and painted,
dust and vermin proof enclosure of MCB DB including copper
/brass bus bar, neutral link, earth bus and DIN rail suitable for
fixing MCB/ isolator etc. fixed on wall using suitable anchor
bolts or fixed in recess including cutting hole on the wall ,
making good the damages, colour washing etc. as required

a1 SP enclosure for independent mounting of MCB E 270.00


a2 DP enclosure for independent mounting of MCB E 207.00
a3 TP enclosure for independent mounting of MCB/ RCCB/ RCBO
E 217.00
a4 FP enclosure for independent mounting of MCB/ RCCB/ RCBO
E 229.00

b1 4 way single phase double cover (IP 42/43) E 879.00


b2 6 way single phase double cover (IP 42/43) E 995.00
b3 8 way single phase double cover (IP 42/43) E 1131.00
b4 10 way single phase double cover (IP 42/43) E 1421.00
b5 12 way single phase double cover (IP 42/43) E 1465.00
b6 14 way single phase double cover (IP 42/43) E 1754.00
b7 16 way single phase double cover (IP 42/43) E 1775.00

c1 4 way single phase double cover (IP 54) E 2615.00


c2 6 way single phase double cover (IP 54) E 2960.00
c3 8 way single phase double cover (IP 54) E 3044.00
c4 10 way single phase double cover (IP 54) E 3387.00
c5 12 way single phase double cover (IP 54) E 3504.00
c6 14 way single phase double cover (IP 54) E 3754.00
c7 16 way single phase double cover (IP 54) E 3862.00

d1 4 way (8+12) - three phase double cover (IP 42/43) E 2056.00


d2 6 way (8+18) - three phase double cover (IP 42/43) E 2537.00
d3 8 way (8+24) - three phase double cover (IP 42/43) E 3113.00
d4 12 way (8+36) - three phase double cover (IP 42/43) E 4234.00
d5 16 way (8+48) - three phase double cover (IP 42/43) E

e1 4 way (8+12) - three phase double cover (IP 54) E 5849.00


e2 6 way (8+18) - three phase double cover (IP 54) E 6999.00
e3 8 way (8+24) - three phase double cover (IP 54) E 7638.00
e4 12 way (8+36) - three phase double cover (IP 54) E 10613.00

f1 4 way (8+12) - double cover TPN vertical DB with provision for


fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP
MCB as outgoing (IP 42/43) E 4402.00
f2 6 way (8+18) - double cover TPN vertical DB with provision for
fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP
MCB as outgoing (IP 42/43) E 5498.00
f3 8 way (8+24) - double cover TPN vertical DB with provision for
fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP
MCB as outgoing (IP 42/43) E 5572.00
f4 12 way (8+36) - double cover TPN vertical DB with provision for
fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP
MCB as outgoing (IP 42/43) E 6861.00

g1 4 way (8+12) - double cover TPN vertical DB with provision for


fixing MCCB as incomer and SP/ TP MCB as outgoing (IP
42/43) E 5498.00
g2 6 way (8+18) - double cover TPN vertical DB with provision for
fixing MCCB as incomer and SP/ TP MCB as outgoing (IP
42/43) E 5970.00
g3 8 way (8+24) - double cover TPN vertical DB with provision for
fixing MCCB as incomer and SP/ TP MCB as outgoing (IP
42/43) E 6400.00
g4 12 way (8+36) - double cover TPN vertical DB with provision for
fixing MCCB as incomer and SP/ TP MCB as outgoing (IP
42/43) E 7421.00

h1 4 way (8+12) - double cover TPN vertical DB with provision for


fixing 250A MCCB as incomer and SP/ TP MCB as outgoing (IP
42/43) E 9458.00
h2 6 way (8+18) - double cover TPN vertical DB with provision for
fixing 250A MCCB as incomer and SP/ TP MCB as outgoing (IP
42/43) E 10265.00
h3 8 way (8+24) - double cover TPN vertical DB with provision for
fixing 250A MCCB as incomer and SP/ TP MCB as outgoing (IP
42/43) E 11096.00
h4 12 way (8+36) - double cover TPN vertical DB with provision for
fixing 250A MCCB as incomer and SP/ TP MCB as outgoing (IP
42/43) E 11591.00

i1 4 way (8+12) - double cover TPN vertical DB with provision for


fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP
MCB as outgoing (IP 54) E 8256.00
i2 6 way (8+18) - double cover TPN vertical DB with provision for
fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP
MCB as outgoing (IP 54) E 9408.00
i3 8 way (8+24) - double cover TPN vertical DB with provision for
fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP
MCB as outgoing (IP 54) E 9975.00
i4 12 way (8+36) -double cover TPN vertical DB with provision for
fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP
MCB as outgoing (IP 54) E 13238.00

j1 4 way (8+12) - double cover TPN vertical DB with provision for


fixing 125A MCCB as incomer and SP/ TP MCB as outgoing (IP
54) E 9472.00
j2 6 way (8+18) - double cover TPN vertical DB with provision for
fixing 125A MCCB as incomer and SP/ TP MCB as outgoing (IP
54) E 10571.00
j3 8 way (8+24) - double cover TPN vertical DB with provision for
fixing 125A MCCB as incomer and SP/ TP MCB as outgoing (IP
54) E 11440.00
j4 12 way (8+36) -double cover TPN vertical DB with provision for
fixing 125A MCCB as incomer and SP/ TP MCB as outgoing (IP
54) E 15175.00

k1 4 way (8+12) - double cover TPN vertical DB with provision for


fixing 250A MCCB as incomer and SP/ TP MCB as outgoing (IP
54) E 13277.00
k2 6 way (8+18) - double cover TPN vertical DB with provision for
fixing 250A MCCB as incomer and SP/ TP MCB as outgoing (IP
54) E 14442.00
k3 8 way (8+24) - double cover TPN vertical DB with provision for
fixing 250A MCCB as incomer and SP/ TP MCB as outgoing (IP
54) E 15235.00
k4 12 way (8+36) -double cover TPN vertical DB with provision for
fixing 250A MCCB as incomer and SP/ TP MCB as outgoing (IP
54) E 17503.00

391 Supply and installation of the following accessories suitable for


50 Hz , AC supply conforming to IS 8828-1995/ IEC 60898 of
the following current ratings in the existing enclosure and giving
connections as required

S & F Mini break isolators


a1 25 A double pole mini break isolator E 309.00
a2 32 A double pole mini break isolator E 332.00
a3 40 A double pole mini break isolator E 332.00
a4 63 A double pole mini break isolator E 410.00
a5 80 A double pole mini break isolator E 528.00
a6 100 A double pole mini break isolator E 548.00
a7 125 A double pole mini break isolator E 565.00

b1 25 A triple pole mini break isolator E 511.00


b2 32 A triple pole mini break isolator E 539.00
b3 40 A triple pole mini break isolator E 589.00
b4 63 A triple pole mini break isolator E 667.00
b5 80 A triple pole mini break isolator E 763.00
b6 100 A triple pole mini break isolator E 824.00
b7 125 A triple pole mini break isolator E 880.00

c1 25 A four pole mini break isolator E 607.00


c2 32 A four pole mini break isolator E 607.00
c3 40 A four pole mini break isolator E 679.00
c4 63 A four pole mini break isolator E 746.00
c5 80 A four pole mini break isolator E 876.00
c6 100 A four pole mini break isolator E 911.00
c7 125 A four pole mini break isolator E 983.00
S & F change-over switches
d1 20 A, single pole, change over switch 2 way E 855.00
d2 20 A, double pole, change over switch 2 way 400V AC E 1667.00
d3 20 A, 2 pole, 2 way, 400V AC change over switch with centre
OFF E 1760.00
S & F RCBO
e1 6 A, 30 mA, 2 pole, 2 module RCBO E 2260.00
e2 10 A, 30 mA, 2 pole, 2 module RCBO E 2260.00
e3 16 A, 30 mA, 2 pole, 2 module RCBO E 2260.00
e4 40 A, 30 mA, 2 pole, 2 module RCBO E 2701.00

f1 6 A, 30 mA, 2 pole, 4 module RCBO E 2280.00


f2 10 A, 30 mA, 2 pole, 4 module RCBO E 2259.00
f3 16 A, 30 mA, 2 pole, 4 module RCBO E 2227.00
f4 25 A, 30 mA, 2 pole, 4 module RCBO E 2227.00
f5 32 A, 30 mA, 2 pole, 4 module RCBO E 2358.00
f6 40 A, 30 mA, 2 pole, 4 module RCBO E 2731.00
f7 63 A, 30 mA, 2 pole, 4 module RCBO E 3139.00

g1 6 A, 100 mA, 2 pole, 2 module RCBO E 2259.00


g2 10 A, 100 mA, 2 pole, 2 module RCBO E 2259.00
g3 16 A, 100 mA, 2 pole, 2 module RCBO E 2259.00
g4 25 A, 100 mA, 2 pole, 2 module RCBO E 2259.00
g5 32 A, 100 mA, 2 pole, 2 module RCBO E 2259.00
g6 40 A, 100 mA, 2 pole, 2 module RCBO E 2701.00

h1 6 A, 100 mA, 2 pole, 4 module RCBO E 2641.00


h2 10 A, 100 mA, 2 pole, 4 module RCBO E 2617.00
h3 16 A, 100 mA, 2 pole, 4 module RCBO E 2580.00
h4 25 A, 100 mA, 2 pole, 4 module RCBO E 2580.00
h5 32 A, 100 mA, 2 pole, 4 module RCBO E 2580.00
h6 40 A, 100 mA, 2 pole, 4 module RCBO E 2779.00
h7 63 A, 100 mA, 2 pole, 4 module RCBO E 3187.00

S & F RCCB
i1 25 A, 2 pole, 30 mA RCCB E 1754.00
i2 40 A, 2 pole, 30 mA RCCB E 1853.00
i3 63 A, 2 pole, 30 mA RCCB E 2282.00
i4 80 A, 2 pole, 30 mA RCCB E 3966.00
i5 100 A, 2 pole, 30 mA RCCB E 4054.00
i6 125 A, 2 pole, 30 mA RCCB E 6485.00

j1 25 A, 4 pole, 30 mA RCCB E 2279.00


j2 40 A, 4 pole, 30 mA RCCB E 2317.00
j3 63 A, 4 pole, 30 mA RCCB E 2651.00
j4 80 A, 4 pole, 30 mA RCCB E 4420.00
j5 100 A, 4 pole, 30 mA RCCB E 4616.00
j6 125 A, 4 pole, 30 mA RCCB E 7008.00

k1 25 A, 2 pole, 100 mA RCCB E 1747.00


k2 40 A, 2 pole, 100 mA RCCB E 1837.00
k3 63 A, 2 pole, 100 mA RCCB E 2368.00
k4 80 A, 2 pole, 100 mA RCCB E 4054.00
k5 100 A, 2 pole, 100 mA RCCB E 4054.00
k6 125 A, 2 pole, 100 mA RCCB E 6485.00

l1 25 A, 4 pole, 100 mA RCCB E 2249.00


l2 40 A, 4 pole, 100 mA RCCB E 2249.00
l3 63 A, 4 pole, 100 mA RCCB E 2569.00
l4 80 A, 4 pole, 100 mA RCCB E 4504.00
l5 100 A, 4 pole, 100 mA RCCB E 4616.00
l6 125A, 4 pole, 100 mA RCCB E 7008.00

m1 25 A, 2 pole, 300 mA RCCB E 1801.00


m2 40 A, 2 pole, 300 mA RCCB E 1837.00
m3 63 A, 2 pole, 300 mA RCCB E 2368.00
m4 80 A, 2 pole, 300 mA RCCB E 4054.00
m5 100 A, 2 pole, 300 mA RCCB E 4054.00
m6 125 A, 2 pole, 300 mA RCCB E 6485.00

n1 25 A, 4 pole, 300 mA RCCB E 2204.00


n2 40 A, 4 pole, 300 mA RCCB E 2332.00
n3 63 A, 4 pole, 300 mA RCCB E 2539.00
n4 80 A, 4 pole, 300 mA RCCB E 4504.00
n5 100 A, 4 pole, 300 mA RCCB E 4616.00
n6 125 A, 4 pole, 300 mA RCCB E 7008.00

S & F SP MCB
p1 6 A to 32 A, 10 kA, SP MCB (B curve) E 167.00
p2 40 A, 10 kA, SP MCB (B curve) E 328.00
p3 50 A and 63 A, 10 kA, SP MCB (B curve) E 392.00

q1 0.50 A to 4 A, 10 kA, SP MCB (C curve) E 250.00


q2 6 A to 32 A, 10 kA, SP MCB (C curve) E 184.00
q3 40 A, 10 kA, SP MCB (C curve) E 342.00
q4 50 A and 63 A, 10 kA, SP MCB (C curve) E 403.00
q5 80 A, 10 kA, SP MCB (C curve) E 1558.00
q6 100 A, 10 kA, SP MCB (C curve) E 1785.00
q7 125 A, 10 kA, SP MCB (C curve) E 2006.00

r1 0.50 A to 4 A, 10 kA, SP MCB (D curve) E 281.00


r2 6 A to 32 A, 10 kA, SP MCB (D curve) E 244.00
r3 40 A, 10 kA, SP MCB (D curve) E 402.00
r4 50 A and 63 A, 10 kA, SP MCB (D curve) E 424.00
S & F DP MCB
s1 0.50 A to 4 A, 10 kA, DP MCB (B curve) E
s2 6 A to 32 A, 10 kA, DP MCB (B curve) E 481.00
s3 40 A, 10 kA, DP MCB (B curve) E 648.00
s4 50 A and 63 A, 10 kA, DP MCB (B curve) E 724.00

t1 0.50 A to 4 A, 10 kA, DP MCB (C curve) E 644.00


t2 6 A to 32 A, 10 kA, DP MCB (C curve) E 526.00
t3 40 A, 10 kA, DP MCB (C curve) E 692.00
t4 50 A and 63 A, 10 kA, DP MCB (C curve) E 824.00
t5 80 A, 10 kA, DP MCB (C curve) E 2999.00
t6 100 A, 10 kA, DP MCB (C curve) E 3588.00
t7 125 A, 10 kA, DP MCB (C curve) E 3942.00

u1 0.50 A to 4 A, 10 kA, DP MCB (D curve) E 707.00


u2 6 A to 32 A, 10 kA, DP MCB (D curve) E 570.00
u3 40 A, 10 kA, DP MCB (D curve) E 827.00
u4 50 A and 63 A, 10 kA, DP MCB (D curve) E 891.00
S & F TP MCB
v1 0.50 A to 4 A, 10 kA, TP MCB (B curve) E
v2 6 A to 32 A, 10 kA, TP MCB (B curve) E 684.00
v3 40 A, 10 kA, TP MCB (B curve) E 931.00
v4 50 A and 63 A, 10 kA, TP MCB (B curve) E 1069.00

w1 0.50 A to 4 A, 10 kA, TP MCB (C curve) E 869.00


w2 6 A to 32 A, 10 kA, TP MCB (C curve) E 774.00
w3 40 A, 10 kA, TP MCB (C curve) E 1042.00
w4 50 A and 63 A, 10 kA, TP MCB (C curve) E 1223.00
w5 80 A, 10 kA, TP MCB (C curve) E 4333.00
w6 100 A, 10 kA, TP MCB (C curve) E 5520.00
w7 125 A, 10 kA, TP MCB (C curve) E 6250.00

x1 0.50 A to 4 A, 10 kA, TP MCB (D curve) E 999.00


x2 6 A to 32 A, 10 kA, TP MCB (D curve) E 873.00
x3 40 A, 10 kA, TP MCB (D curve) E 1199.00
x4 50 A and 63 A, 10 kA, TP MCB (D curve) E 1334.00
S & F FP MCB
y1 0.50 A to 4 A, 10 kA, 4 pole MCB (B curve) E
y2 6 A to 32 A, 10 kA, 4 pole MCB (B curve) E 989.00
y3 40 A, 10 kA, 4 pole MCB (B curve) E 1256.00
y4 50 A and 63 A, 10 kA, 4 pole MCB (B curve) E 1417.00

z1 0.50 A to 4 A, 10 kA, 4 pole MCB (C curve) E 1256.00


z2 6 A to 32 A, 10 kA, 4 pole MCB (C curve) E 1122.00
z3 40 A, 10 kA, 4 pole MCB (C curve) E 1379.00
z4 50 A and 63 A, 10 kA, 4 pole MCB (C curve) E 1547.00
z5 63 A, 10 kA, 4 pole MCB (C curve) E
z6 80 A, 10 kA, 4 pole MCB (C curve) E 5936.00
z7 100 A, 10 kA, 4 pole MCB (C curve) E 7946.00
z8 125 A, 10 kA, 4 pole MCB (C curve) E 8985.00

aa1 0.50 A to 4 A, 10 kA, 4 pole MCB (D curve) E 1356.00


aa2 6 A to 32 A, 10 kA, 4 pole MCB (D curve) E 1145.00
aa3 40 A, 10 kA, 4 pole MCB (D curve) E 1590.00
aa4 50 A and 63 A, 10 kA, 4 pole MCB (D curve) E 1674.00
S & F common accessories for MCB/ Isolator/ RCD
395 Supply and installation of the following types of common
accessories for MCB/ isolator/ RCD etc conforming to relevant
ISS in the existing enclosure and giving connections as required

a1 Auxiliary change over switch 6A, 250 V, AC 1/2 M E 544.00


a2 Fault signaling change over switch 6A, 250 V, AC 1/2 M E 639.00
a3 Auxiliary change over switch which can be modified to a fault 1021.00
signaling switch 6A, 250 V, AC 1/2 M E
a4 Auxiliary change over switch + fault signaling switch which can 1755.00
be modified to 2 auxiliary change over switches 1 M E
a5 Shunt trip - 12 to 48 V AC/ DC - I module E 1471.00
a6 Shunt trip - 110 to 415 V AC & 110 V to 125 V DC - I module
E 1471.00
a7 Remote control trip for DP/ TP/ FP MCB with auxiliary change
over and fault signaling unit - 230 V AC, 3 M E 15847.00
a8 Minimum voltage trips Time delay adjustable from 0 to 300 ms 1273.00
24 V DC 1 M / 48 V DC 1 M / 230 V AC 1 M E
S & F RCBO (Hpi earth leakage, over load & short circuit
protection)
396 Supply and installation of the following RCBO (Hpi earth
leakage, over load & short circuit protection with enhanced
immunity to unwanted tripping in environment with disturbances
(eg. DG sets, computers, printers, thyristors etc) suitable for 50
Hz AC supply in the existing enclosure and giving connections as
required

a1 25 A, 2 pole, RCBO 30 mA 2 module (Group B) E 5268.00


a2 32 A, 2 pole, RCBO 30 mA 2 module (Group B) E 5536.00
a3 40 A, 2 pole, RCBO 30 mA 2 module (Group B) E 6527.00
S & F RCCB (Hpi earth leakage protection)
397 Supply and installation of the following RCCB (Hpi earth leakage
protection with enhanced immunity to unwanted tripping in
environment with disturbances (eg. DG sets, computers, printers,
thyristors etc) suitable for 50 Hz AC supply conforming to IS
12640 part I / IEC 661008 part I, in the existing enclosure and
giving connections as required

a1 25 A, 2 pole, 30 mA E 3956.00
a2 40 A, 2 pole, 30 mA E 4145.00
a3 63 A, 2 pole, 30 mA E 42428.00

c1 25 A, 4 pole, 30 mA E 4375.00
c2 40 A, 4 pole, 30 mA E 4534.00
c3 63 A, 4 pole, 30 mA E 4653.00
c4 80 A, 4 pole, 30 mA E

S & F power contactors suitable for mounting on MCB DB

398 Supply and installation of the following types of 250 V, 50 Hz


AC power contactors suitable for mounting on MCB DB and
giving connections as required
a Nominal rating 16 A - 2 NO - 2 pole E
b Nominal rating 20 A - 2 NO - 2 pole E 1119.00
c Nominal rating 20 A - 2 NC - 2 pole E 1118.00
d Nominal rating 40 A - 2 NO - 2 pole E 1942.00
e Nominal rating 40 A - 3 NO - 3 pole E 3180.00
S & F ammeters suitable for mounting on MCB DB
399 Supply and installation of the following types of ammeters
suitable for mounting on MCB DB and giving connections as
required
a Direct connection to AC/ DC (0-30 A) - 4 module E 3038.00
b Connected using a -/5 A CT - 4 module E 3038.00
c Measuring dial for ammeter E 183.00
S & F CTs for mounting on MCB DB
400 Supply and installation of the following types of CTs suitable for
mounting on MCB DB and giving connections as required

a 50 / 5 A E 1389.00
b 100 / 5 A E 1852.00
d 200 / 5 A E 1915.00
e 300 / 5 A E 1915.00
f 400 / 5 A E 1920.00
g 600 / 5 A E 1920.00
h 800 / 5 A E 2855.00
i 1000 / 5 A E 3228.00
j 1200 / 5 A E 3764.00
S & F voltmeters for mounting on MCB DB
401 Supply and installation of the following types of voltmeters and
selector switches suitable for mounting on MCB DB and giving
connections as required
a 0 - 500 V, AC/ DC - 4 module, analogue type voltmeter E 3179.00
b 0 - 500 V/ 0 - 1200 V AC - 4 module, digital A/M or V/M E 8046.00
c 4 position ammeter selector switch - 3 M E 3325.00
d 5 position volt meter selector switch - 3 M E 3049.00
e 7 position volt meter selector switch - 3 M E 3214.00
S & F MOTOR PROTECTION CIRCUIT BREAKERS (MPCB)

405 Supply and installation of the following types of MPCBs (gives


protection against overload & shot circuit to 3 phase motors) in
the existing MCB DB/ fabricated enclosure and giving
connections as required

a1 With nominal rating of 0.16 A & adjustable thermal range of 0.10


- 0.16 A 2761.00
a2 With nominal rating of 0.25 A & adjustable thermal range of 0.16
- 0.25 A 2761.00
a3 With nominal rating of 0.40 A & adjustable thermal range of 0.25
- 0.40 A 2761.00
a4 With nominal rating of 0.63 A & adjustable thermal range of 0.40
- 0.63 A 2813.00
a5 With nominal rating of 1.00 A & adjustable thermal range of
0..63 - 1.00 A 2844.00
a6 With nominal rating of 1.60 A & adjustable thermal range of 1.00
- 1.60 A 3127.00
a7 With nominal rating of 2.50 A & adjustable thermal range of 1.60
- 2.5 A 3127.00
a8 With nominal rating of 4.00 A & adjustable thermal range of 2.50
- 4.00 A 3127.00
a9 With nominal rating of 6.30 A & adjustable thermal range of 4.00
- 6.30 A 3127.00
a10 With nominal rating of 10 A & adjustable thermal range of 6.30 3242.00
- 10 A
a11 With nominal rating of 16 A & adjustable thermal range of 10 - 3546.00
16 A
a12 With nominal rating of 20 A & adjustable thermal range of 16 - 3546.00
20 A
a13 With nominal rating of 25 A & adjustable thermal range of 20 - 3650.00
25 A

PART XIII
SH: SUPPLY & FIXING ISOLATORS, SDF & COS
410 Supply and installation of switch gear units in sheet steel
enclosure complete with handle assembly, door interlock and pad
locking arrangement of the following ratings on existing angle
iron frame work or directly to wall using necessary bolts & nuts,
fixing the unit to wall, making good the damages, colour washing
etc. including giving necessary connections as required.
(excluding cost of HRC fuse links in case of SDF/ SDFCO)

AC 23 A duty TP/ TPN SDU in sheet steel enclosure


a1 32 A, 415 V, 50 Hz, AC 23 A duty, TP/ TPN switch disconnector
unit E 2005.00
a2 40 A, 415 V, 50 Hz, AC 23 A duty, TP/ TPN switch disconnector
unit E 2085.00
a3 63 A, 415 V, 50 Hz, AC 23 A duty, TP/ TPN switch disconnector
unit E 2316.00
a4 80A, 415 V, 50 Hz, AC 23 A duty, TP/ TPN switch disconnector
unit E 2439.00
a5 100 A, 415 V, 50 Hz, AC 23 A duty, TP/ TPN switch
disconnector unit E 3594.00
a6 125 A, 415 V, 50 Hz, AC 23 A duty, TP/ TPN switch
disconnector unit E 4039.00
a7 160 A, 415 V, 50 Hz, AC 23 A duty, TP/ TPN switch
disconnector unit E 5030.00
a8 200 A, 415 V, 50 Hz, AC 23 A duty, TP/ TPN switch
disconnector unit E 5631.00
a9 250 A, 415 V, 50 Hz, AC 23 A duty, TP/ TPN switch
disconnector unit E 6838.00
a10 315 A, 415 V, 50 Hz, AC 23 A duty, TP/ TPN switch
disconnector unit E 7909.00
a11 400 A, 415 V, 50 Hz, AC 23 A duty, TP/ TPN switch
disconnector unit E 10178.00
a12 630 A, 415 V, 50 Hz, AC 23 A duty, TP/ TPN switch
disconnector unit E 12871.00
AC 23 A duty 4 pole SDU in sheet steel enclosure
b1 32 A, 415 V, 50 Hz, AC 23 A duty, 4 pole switch disconnector
unit E 1825.00
b2 40 A, 415 V, 50 Hz, AC 23 A duty, 4 pole switch disconnector
unit E 1903.00
b3 63 A, 415 V, 50 Hz, AC 23 A duty, 4 pole switch disconnector
unit E 2113.00
b4 80A, 415 V, 50 Hz, AC 23 A duty, 4 pole switch disconnector
unit E 2774.00
b5 100 A, 415 V, 50 Hz, AC 23 A duty, 4 pole switch disconnector
unit E 3858.00
b6 125 A, 415 V, 50 Hz, AC 23 A duty, 4 pole switch disconnector
unit E 4309.00
b7 160 A, 415 V, 50 Hz, AC 23 A duty, 4 pole switch disconnector
unit 5116.00
b8 200 A, 415 V, 50 Hz, AC 23 A duty, 4 pole switch disconnector
unit E 6103.00
b9 250 A, 415 V, 50 Hz, AC 23 A duty, 4 pole switch disconnector
unit E 7731.00
b10 315 A, 415 V, 50 Hz, AC 23 A duty, 4 pole switch disconnector
unit 8707.00
b11 400 A, 415 V, 50 Hz, AC 23 A duty, 4 pole switch disconnector
unit E 11213.00
b12 630 A, 415 V, 50 Hz, AC 23 A duty, 4 pole switch disconnector
unit E 13339.00
AC 23 A duty TPN SDF in sheet steel enclosure for DIN fuse

c1 32 A, 415 V, 50 Hz, AC 23 A duty, TPN SDF for DIN fuse E 2604.00


c2 63 A, 415 V, 50 Hz, AC 23 A duty, TPN SDF for DIN fuse E 3240.00
c3 80 A, 415 V, 50 Hz, AC 23 A duty, TPN SDF for DIN fuse E 4492.00
c4 100 A, 415 V, 50 Hz, AC 23 A duty, TPN SDF for DIN fuse
E 5178.00
c5 125 A, 415 V, 50 Hz, AC 23 A duty, TPN SDF for DIN fuse
E 5939.00
c6 160 A, 415 V, 50 Hz, AC 23 A duty, TPN SDF for DIN fuse
E 7317.00
c7 200 A, 415 V, 50 Hz, AC 23 A duty, TPN SDF for DIN fuse
E 7736.00
c8 250 A, 415 V, 50 Hz, AC 23 A duty, TPN SDF for DIN fuse
E 9787.00
c9 315 A, 415 V, 50 Hz, AC 23 A duty, TPN SDF for DIN fuse
E 11240.00
c10 400 A, 415 V, 50 Hz, AC 23 A duty, TPN SDF for DIN fuse
E 13070.00
c11 500 A, 415 V, 50 Hz, AC 23 A duty, TPN SDF for DIN fuse
E 17940.00
c12 630 A, 415 V, 50 Hz, AC 23 A duty, TPN SDF for DIN fuse E 20127.00
AC 23 A duty TPN SDF in sheet steel enclosure for BS fuse

d1 32 A, 415 V, 50 Hz, AC 23 A duty, TPN SDF for BS fuse E 2148.00


d2 63 A, 415 V, 50 Hz, AC 23 A duty, TPN SDF for BS fuse E 2636.00
d3 100 A, 415 V, 50 Hz, AC 23 A duty, TPN SDF for BS fuse E 4769.00
d4 125 A, 415 V, 50 Hz, AC 23 A duty, TPN SDF for BS fuse E 5325.00
d5 160 A, 415 V, 50 Hz, AC 23 A duty, TPN SDF for BS fuse E 7128.00
d6 200 A, 415 V, 50 Hz, AC 23 A duty, TPN SDF for BS fuse E 7495.00
d7 250 A, 415 V, 50 Hz, AC 23 A duty, TPN SDF for BS fuse E 8760.00
d8 315 A, 415 V, 50 Hz, AC 23 A duty, TPN SDF for BS fuse E 10523.00
d9 400 A, 415 V, 50 Hz, AC 23 A duty, TPN SDF for BS fuse E 12843.00
d10 630 A, 415 V, 50 Hz, AC 23 A duty, TPN SDF for BS fuse E 20728.00
AC 23 A duty FP SDF in sheet steel enclosure for DIN fuse

e1 32 A, 415 V, 50 Hz, AC 23 A duty, 4 pole SDF for DIN fuse E 2932.00


e2 63 A, 415 V, 50 Hz, AC 23 A duty, 4 pole SDF for DIN fuse E 3432.00
e3 100 A, 415 V, 50 Hz, AC 23 A duty, 4 pole SDF for DIN fuse
E 6163.00
e4 125 A, 415 V, 50 Hz, AC 23 A duty, 4 pole SDF for DIN fuse
E 6421.00
e5 160 A, 415 V, 50 Hz, AC 23 A duty, 4 pole SDF for DIN fuse
E 8273.00
e6 200 A, 415 V, 50 Hz, AC 23 A duty, 4 pole SDF for DIN fuse
E 9131.00
e7 250 A, 415 V, 50 Hz, AC 23 A duty, 4 pole SDF for DIN fuse
E 9785.00
e8 315 A, 415 V, 50 Hz, AC 23 A duty, 4 pole SDF for DIN fuse
E 13507.00
e9 400 A, 415 V, 50 Hz, AC 23 A duty, 4 pole SDF for DIN fuse
E 13680.00
e10 630 A, 415 V, 50 Hz, AC 23 A duty, 4 pole SDF for DIN fuse
E 22622.00
AC 23 A duty FP SDF in sheet steel enclosure for BS fuse

f1 32 A, 415 V, 50 Hz, AC 23 A duty, 4 pole SDF for BS fuse E 2909.00


f2 63 A, 415 V, 50 Hz, AC 23 A duty, 4 pole SDF for BS fuse E 3432.00
f3 100 A, 415 V, 50 Hz, AC 23 A duty, 4 pole SDF for BS fuse E 5638.00
f4 125 A, 415 V, 50 Hz, AC 23 A duty, 4 pole SDF for BS fuse E 6421.00
f5 160 A, 415 V, 50 Hz, AC 23 A duty, 4 pole SDF for BS fuse E 8167.00
f6 200 A, 415 V, 50 Hz, AC 23 A duty, 4 pole SDF for BS fuse E 9131.00
f7 250 A, 415 V, 50 Hz, AC 23 A duty, 4 pole SDF for BS fuse E 9785.00
f8 315 A, 415 V, 50 Hz, AC 23 A duty, 4 pole SDF for BS fuse E 12773.00
f9 400 A, 415 V, 50 Hz, AC 23 A duty, 4 pole SDF for BS fuse E 14082.00
f10 630 A, 415 V, 50 Hz, AC 23 A duty, 4 pole SDF for BS fuse E 23881.00
AC 23 A duty FP on-load COS in sheet steel enclosure
g1 40A, 415 V, 50 Hz, AC 23 A duty, 4 pole on-load change over
switch 4824.00
g2 63 A, 415 V, 50 Hz, AC 23 A duty, 4 pole on-load change over
switch E 4833.00
g3 80 A, 415 V, 50 Hz, AC 23 A duty, 4 pole on-load change over
switch 5867.00
g4 100 A, 415 V, 50 Hz, AC 23 A duty, 4 pole on-load change over
switch E 7079.00
g5 125 A, 415 V, 50 Hz, AC 23 A duty, 4 pole on-load change over
switch E 8690.00
g6 160 A, 415 V, 50 Hz, AC 23 A duty, 4 pole on-load change over
switch E 9304.00
g7 200 A, 415 V, 50 Hz, AC 23 A duty, 4 pole on-load change over
switch E 10767.00
g8 250 A, 415 V, 50 Hz, AC 23 A duty, 4 pole on-load change over
switch E 15186.00
g9 315 A, 415 V, 50 Hz, AC 23 A duty, 4 pole on-load change over
switch E 15713.00
g10 400 A, 415 V, 50 Hz, AC 23 A duty, 4 pole on-load change over
switch E 22860.00
g11 630 A, 415 V, 50 Hz, AC 23 A duty, 4 pole on-load change over
switch E 26157.00
AC 23 A duty FP on-load SDF Change Over in sheet steel
enclosure.
h1 125 A, 415 V, 50 Hz, AC 23 A duty, 4 pole on-load switch
disconnector fuse change over E 10455.00
h2 200 A, 415 V, 50 Hz, AC 23 A duty, 4 pole on-load switch
disconnector fuse change over E 20032.00
h3 250 A, 415 V, 50 Hz, AC 23 A duty, 4 pole on-load switch
disconnector fuse change over E 21236.00
h4 315 A, 415 V, 50 Hz, AC 23 A duty, 4 pole on-load switch
disconnector fuse change over E 21719.00
h5 400 A, 415 V, 50 Hz, AC 23 A duty, 4 pole on-load switch
disconnector fuse change over E 32002.00
h6 630 A, 415 V, 50 Hz, AC 23 A duty, 4 pole on-load switch
disconnector fuse change over E 38144.00
S & F Frame-work for fixing SDU/ SDF/ COS
411 Fabrication, supply, conveyance and fixing frame work made out
of suitable size angle iron/ flat cut and welded to shape of
suitable size painted with 2 coats of synthetic enamel paint over a
coat of red oxide primer & with drilled holes to mount the switch
gear, fixed to wall using suitable size anchor bolts or grouted to
wall, making good the damages, colour washing etc as required

Kg 95.50
412 Fabrication, supply, conveyance and fixing cable entry/ wire way
box made out 1.60 mm CRCA sheet of suitable size to match the
switch gear and enabling the cables to be connected without
strain, painted with 2 coats of synthetic enamel paint over a coat
of red oxide primer & with drilled holes and mounting to the
switch gear etc as required.
Kg 101.00
413 Fabrication, supply, conveyance and fixing cable entry/ wire way
box made out 1.60 mm CRCA sheet of suitable size to match the
switch gear and enabling the cables to be connected without
strain, powder coated after subjecting to 7 tank process & with
drilled holes and mounting to the switch gear etc as required.

Kg 129.00
PART XIV
SH: CABLING
Laying of power cable in original position with sand cushioning
& protective covering (in ordinary soil)
520 Laying of one number PVC insulated and PVC sheathed
armoured power cable of 1.1KV grade of the following sizes in
ground including excavation of trench of size 35 x 75 cm, sand
cushioning up to a height of 25cm (80+170mm), providing
protective covering with country burnt bricks laid breadth wise,
refilling the trench etc. as required (in ordinary soil).

a Cable size not exceeding 25 sq mm m 294.00


b Cable size exceeding 25 sq mm but not exceeding 120 sq mm
m 305.00
c Cable size exceeding 120 sq mm but not exceeding 400 sq mm
m 316.00
Laying of power cable in additional position with sand
cushioning & protective covering (in ordinary soil)
521 Laying of one number additional PVC insulated and PVC
sheathed armoured power cable of 1.1KV grade of the following
sizes in ground in the same trench in one tier horizontal formation
including widening the trench by 20 cm, sand cushioning up to
height of 25cm, providing protective covering with country burnt
bricks laid breadth wise, refilling the trench etc. as required (in
ordinary soil).

a Cable size not exceeding 25 sq mm m 179.00


b Cable size exceeding 25 sq mm but not exceeding 120 sq mm
m 185.00
c Cable size exceeding 120 sq mm but not exceeding 400 sq mm
m 190.00
Laying of power cable in original position without sand
cushioning & protective covering (in ordinary soil)
522 Laying of one number PVC insulated and PVC sheathed
armoured power cable of 1.1KV grade of the following sizes in
ground including excavation of trench of size 35 x 75 cm,
refilling the trench etc. as required but excluding sand cushioning
and protective covering (in ordinary soil).

a Cable size not exceeding 25 sq mm m 70.00


b Cable size exceeding 25 sq mm but not exceeding 120 sq mm
m 82.00
c Cable size exceeding 120 sq mm but not exceeding 400 sq mm
m 93.00
Laying of power cable in additional position without sand
cushioning & protective covering (in ordinary soil)
523 Laying of one number additional PVC insulated and PVC
sheathed armoured power cable of 1.1KV grade of the following
sizes in ground in the same trench in one tier horizontal formation
including widening the trench by 20 cm, refilling the trench etc.
as required but excluding sand cushioning and protective
covering (in ordinary soil)

a Cable size not exceeding 25 sq mm m 38.00


b Cable size exceeding 25 sq mm but not exceeding 120 sq mm
m 43.00
c Cable size exceeding 120 sq mm but not exceeding 400 sq mm
m 49.00
Laying of power cable in original position with sand cushioning
& protective covering (in hard soil)
524 Laying of one number PVC insulated and PVC sheathed
armoured power cable of 1.1KV grade of the following sizes in
ground including excavation of trench of size 35 x 75 cm, sand
cushioning up to a height of 25cm (80+170mm), providing
protective covering with country burnt bricks laid breadth wise,
refilling the trench etc. as required (in hard soil).

a Cable size not exceeding 25 sq mm m 315.00


b Cable size exceeding 25 sq mm but not exceeding 120 sq mm
m 326.00
c Cable size exceeding 120 sq mm but not exceeding 400 sq mm
m 337.00
Laying of power cable in additional position with sand
cushioning & protective covering (in hard soil)
525 Laying of one number additional PVC insulated and PVC
sheathed armoured power cable of 1.1KV grade of the following
sizes in ground in the same trench in one tier horizontal formation
including widening the trench by 20 cm, sand cushioning up to
height of 25cm, providing protective covering with country burnt
bricks laid breadth wise, refilling the trench etc. as required (in
hard soil).

a Cable size not exceeding 25 sq mm m 191.00


b Cable size exceeding 25 sq mm but not exceeding 120 sq mm
m 197.00
c Cable size exceeding 120 sq mm but not exceeding 400 sq mm
m 202.00
Laying of power cable in original position without sand
cushioning & protective covering (in hard soil)
526 Laying of one number PVC insulated and PVC sheathed
armoured power cable of 1.1KV grade of the following sizes in
ground including excavation of trench of size 35 x 75 cm,
refilling the trench etc. as required but excluding sand cushioning
and protective covering (in hard soil).

a Cable size not exceeding 25 sq mm m 91.50


b Cable size exceeding 25 sq mm but not exceeding 120 sq mm
m 103.00
c Cable size exceeding 120 sq mm but not exceeding 400 sq mm
m 114.00
Laying of power cable in additional position without sand
cushioning & protective covering (in hard soil)
527 Laying of one number additional PVC insulated and PVC
sheathed armoured power cable of 1.1KV grade of the following
sizes in ground in the same trench in one tier horizontal formation
including widening the trench by 20 cm, refilling the trench etc.
as required but excluding sand cushioning and protective
covering (in hard soil)

a Cable size not exceeding 25 sq mm m 50.00


b Cable size exceeding 25 sq mm but not exceeding 120 sq mm
m 55.00
c Cable size exceeding 120 sq mm but not exceeding 400 sq mm
m 61.00
Laying of power cable in original position with sand cushioning
& protective covering (in ordinary rocky soil)
528 Laying of one number PVC insulated and PVC sheathed
armoured power cable of 1.1KV grade of the following sizes in
ground including excavation of trench of size 35 x 75 cm, sand
cushioning up to a height of 25cm (80+170mm), providing
protective covering with country burnt bricks laid breadth wise,
refilling the trench etc. as required (in ordinary rocky - soft
laterite soil).

a Cable size not exceeding 25 sq mm m 355.00


b Cable size exceeding 25 sq mm but not exceeding 120 sq mm
m 366.00
c Cable size exceeding 120 sq mm but not exceeding 400 sq mm
m 377.00
Laying of power cable in additional position with sand
cushioning & protective covering (in ordinary rocky soil)

529 Laying of one number additional PVC insulated and PVC


sheathed armoured power cable of 1.1KV grade of the following
sizes in ground in the same trench in one tier horizontal formation
including widening the trench by 20 cm, sand cushioning up to
height of 25cm, providing protective covering with country burnt
bricks laid breadth wise, refilling the trench etc. as required (in
ordinary rocky - soft laterite soil).
a Cable size not exceeding 25 sq mm m 214.00
b Cable size exceeding 25 sq mm but not exceeding 120 sq mm
m 219.00
c Cable size exceeding 120 sq mm but not exceeding 400 sq mm
m 225.00
Laying of power cable in original position without sand
cushioning & protective covering (in ordinary rocky soil)

530 Laying of one number PVC insulated and PVC sheathed


armoured power cable of 1.1KV grade of the following sizes in
ground including excavation of trench of size 35 x 75 cm,
refilling the trench etc. as required but excluding sand cushioning
and protective covering (in ordinary rocky - soft laterite soil).

a Cable size not exceeding 25 sq mm m 131.00


b Cable size exceeding 25 sq mm but not exceeding 120 sq mm
m 143.00
c Cable size exceeding 120 sq mm but not exceeding 400 sq mm
m 154.00
531 Laying of power cable in additional position without sand
cushioning & protective covering (in ordinary rocky soil)
a Cable size not exceeding 25 sq mm m 72.00
b Cable size exceeding 25 sq mm but not exceeding 120 sq mm
m 78.00
c Cable size exceeding 120 sq mm but not exceeding 400 sq mm
m 83.00
Laying of power cable through pipe
532 Laying of one number PVC insulated and PVC sheathed
armoured power cable of 1.1KV grade of the following sizes in
the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as
required.

a Cable size not exceeding 25 sq mm m 29.50


b Cable size exceeding 25 sq mm but not exceeding 400 sq mm
m 41.00
Laying of power cable in masonry open duct
533 Laying of one No. PVC insulated and PVC sheathed armoured
power cable of 1.1 KV grade of the following sizes in the existing
masonry open duct as required.
a Cable size not exceeding 25 sq mm m 24.00
b Cable size exceeding 25 sq mm but not exceeding 400 sq mm
m 32.00
Laying & clamping of power cable
534 Laying and clamping of 1 no. PVC insulated and PVC sheathed
armoured power cable, 1.1 KV grade of the following sizes using
clamps noted along with the cables, spacing of clamps not
exceeding 60cms, making good the damages , colour washing etc.
as required.

2 Core cable
a1 2 core cable of size not exceeding 4 sq mm with company
fabricated saddles m 37.00
a2 2 core cable of size exceeding 4 sq mm but not exceeding 16 sq
mm with company fabricated saddles m 40.50
a3 2 core cable of size exceeding 16 sq mm but not exceeding 35 sq
mm with company fabricated saddles m 49.00
a4 2 core cable of size exceeding 35 sq mm but not exceeding 95 sq
mm with company fabricated saddles m 56.00
a5 2 core cable of size exceeding 95 sq mm but not exceeding 185 sq
mm with company fabricated saddles m 66.00
a6 2 core cable of size exceeding 185 sq mm but not exceeding 400
sq mm with clamps fabricated from 25 x 3 mm MS flat m 89.50
3 Core cable
b1 3 core cable of size not exceeding 4 sq mm with company
fabricated saddles m 37.00
b2 3 core cable of size exceeding 4 sq mm but not exceeding 16 sq
mm with company fabricated saddles m 40.50
b3 3 core cable of size exceeding 16 sq mm but not exceeding 35 sq
mm with company fabricated saddles m 49.00
b4 3 core cable of size exceeding 35 sq mm but not exceeding 70 sq
mm with company fabricated saddles m 56.00
b5 3 core cable of size exceeding 70 sq mm but not exceeding 120 sq
mm with company fabricated saddles m 66.00
b6 3 core cable of size exceeding 120 sq mm but not exceeding 400
sq mm with clamps fabricated from 25 x 3 mm MS flat m 89.50
3.5 Core cable
c1 3.5 core cable of size exceeding 16 sq mm but not exceeding 35
sq mm with company fabricated saddles m 49.00
c2 3.5 core cable of size exceeding 25 sq mm but not exceeding 50
sq mm with company fabricated saddles m 56.00
c3 3.5 core cable of size exceeding 50 sq mm but not exceeding 95
sq mm with company fabricated saddles m 66.00
c4 3.5 core cable of size exceeding 95 sq mm but not exceeding 120
sq mm with clamps fabricated from 25 x 3 mm MS flat m 73.00
c5 3.5 core cable of size exceeding 120 sq mm but not exceeding
400 sq mm with clamps fabricated from 25 x 3 mm MS flat
m 89.50
4 Core cable
d1 4 core cable of size not exceeding 6 sq mm with company
fabricated saddles. m 40.50
d2 4 core cable of size exceeding 6 sq mm but not exceeding 25 sq
mm with company fabricated saddles m 49.00
d3 4 core cable of size exceeding 25 sq mm but not exceeding 50 sq
mm with company fabricated saddles m 56.00
d4 4 core cable of size exceeding 50 sq mm but not exceeding 95 sq
mm with company fabricated saddles m 66.00
d5 4 core cable of size exceeding 95 sq mm but not exceeding 120 sq
mm with company fabricated saddles m 73.00
d6 4 core cable of size exceeding 120 sq mm but not exceeding 400
sq mm with clamps fabricated from 25 x 3 mm MS flat m 89.50
Supply & laying Aluminium power cable 1.1 KV grade in
original position with sand cushioning & protective covering in
ordinary soil
535 Supply & laying of one number PVC insulated and PVC sheathed
armoured aluminium power cable of 1.1KV grade of the
following sizes in ground including excavation of trench of size
35 x 75 cm, sand cushioning up to a height of 25cm
(80+170mm), providing protective covering with country burnt
bricks laid breadth wise, refilling the trench etc. as required (in
ordinary soil).

a1 2 core 4 sq mm m 375.00
a2 2 core 6 sq mm m 394.00
a3 2 core 10 sq mm m 402.00
a4 2 core 16 sq mm m 410.00
a5 2 core 25 sq mm m 423.00
a6 2 core 35 sq mm m 463.00
a7 2 core 50 sq mm m 508.00
a8 2 core 70 sq mm m 570.00
a9 2 core 95 sq mm m 629.00
a10 2 core 120 sq mm m 693.00
a11 2 core 150 sq mm m 784.00
a12 2 core 185 sq mm m 889.00
a13 2 core 240 sq mm m 4048.00
a14 2 core 300 sq mm m 1213.00
a15 2 core 400 sq mm m 1437.00

b1 3 core 4 sq mm m 383.00
b2 3 core 6 sq mm m 409.00
b3 3 core 10 sq mm m 420.00
b4 3 core 16 sq mm m 434.00
b5 3 core 25 sq mm m 467.00
b6 3 core 35 sq mm m 526.00
b7 3 core 50 sq mm m 582.00
b8 3 core 70 sq mm m 668.00
b9 3 core 95 sq mm m 752.00
b10 3 core 120 sq mm m 848.00
b11 3 core 150 sq mm m 976.00
b12 3 core 185 sq mm m 1119.00
b13 3 core 240 sq mm m 1356.00
b14 3 core 300 sq mm m 1590.00
b15 3 core 400 sq mm m 1917.00

c1 3.5 core 25 sq mm m 499.00


c2 3.5 core 35 sq mm m 546.00
c3 3.5 core 50 sq mm m 625.00
c4 3.5 core 70 sq mm m 724.00
c5 3.5 core 95 sq mm m 822.00
c6 3.5 core 120 sq mm m 958.00
c7 3.5 core 150 sq mm m 1073.00
c8 3.5 core 185 sq mm m 1255.00
c9 3.5 core 240 sq mm m 1518.00
c10 3.5 core 300 sq mm m 1788.00
c11 3.5 core 400 sq mm m 2168.00

d1 4 core 4 sq mm m 402.00
d2 4 core 6 sq mm m 422.00
d3 4 core 10 sq mm m 426.00
d4 4 core 16 sq mm m 460.00
d5 4 core 25 sq mm m 510.00
d6 4 core 35 sq mm m 574.00
d7 4 core 50 sq mm m 658.00
d8 4 core 70 sq mm m 770.00
d9 4 core 95 sq mm m 885.00
d10 4 core 120 sq mm m 1012.00
d11 4 core 150 sq mm m 1171.00
d12 4 core 185 sq mm m 1369.00
d13 4 core 240 sq mm m 1675.00
d14 4 core 300 sq mm m 1988.00
d15 4 core 400 sq mm m 2428.00
Supply & laying Aluminium power cable 1.1 KV grade in
additional position with sand cushioning & protective covering
in ordinary soil
536 Supply & laying of one number additional PVC insulated and
PVC sheathed armoured aluminium power cable of 1.1KV grade
of the following sizes in ground in the same trench in one tier
horizontal formation including widening the trench by 20 cm,
sand cushioning up to height of 25cm, providing protective
covering with country burnt bricks laid breadth wise, refilling the
trench etc. as required (in ordinary soil).

a1 2 core 4 sq mm m 261.00
a2 2 core 6 sq mm m 280.00
a3 2 core 10 sq mm m 288.00
a4 2 core 16 sq mm m 296.00
a5 2 core 25 sq mm m 309.00
a6 2 core 35 sq mm m 344.00
a7 2 core 50 sq mm m 389.00
a8 2 core 70 sq mm m 451.00
a9 2 core 95 sq mm m 509.00
a10 2 core 120 sq mm m 573.00
a11 2 core 150 sq mm m 659.00
a12 2 core 185 sq mm m 764.00
a13 2 core 240 sq mm m 923.00
a13 2 core 300 sq mm m 1088.00
a14 2 core 400 sq mm m 1312.00

b1 3 core 4 sq mm m 269.00
b2 3 core 6 sq mm m 295.00
b3 3 core 10 sq mm m 306.00
b4 3 core 16 sq mm m 320.00
b5 3 core 25 sq mm m 353.00
b6 3 core 35 sq mm m 406.00
b7 3 core 50 sq mm m 463.00
b8 3 core 70 sq mm m 548.00
b9 3 core 95 sq mm m 633.00
b10 3 core 120 sq mm m 729.00
b11 3 core 150 sq mm m 580.00
b12 3 core 185 sq mm m 994.00
b13 3 core 240 sq mm m 1231.00
b14 3 core 300 sq mm m 1465.00
b15 3 core 400 sq mm m 1792.00

c1 3.5 core 25 sq mm m 385.00


c2 3.5 core 35 sq mm m 427.00
c3 3.5 core 50 sq mm m 505.00
c4 3.5 core 70 sq mm m 605.00
c5 3.5 core 95 sq mm m 703.00
c6 3.5 core 120 sq mm m 839.00
c7 3.5 core 150 sq mm m 948.00
c8 3.5 core 185 sq mm m 1130.00
c9 3.5 core 240 sq mm m 1393.00
c10 3.5 core 300 sq mm m 1662.00
c11 3.5 core 400 sq mm m 2043.00

d1 4 core 4 sq mm m 289.00
d2 4 core 6 sq mm m 308.00
d3 4 core 10 sq mm m 312.00
d4 4 core 16 sq mm m 346.00
d5 4 core 25 sq mm m 396.00
d6 4 core 35 sq mm m 454.00
d7 4 core 50 sq mm m 538.00
d8 4 core 70 sq mm m 651.00
d9 4 core 95 sq mm m 766.00
d10 4 core 120 sq mm m 893.00
d11 4 core 150 sq mm m 1046.00
d12 4 core 185 sq mm m 1244.00
d13 4 core 240 sq mm m 1550.00
d14 4 core 300 sq mm m 1863.00
d15 4 core 400 sq mm m 2302.00
Supply & laying Aluminium power cable 1.1 KV grade in
original position without sand cushioning & protective covering
in ordinary soil
537 Supply & laying of one number PVC insulated and PVC sheathed
armoured aluminium power cable of 1.1KV grade of the
following sizes in ground including excavation of trench of size
35 x 75 cm, refilling the trench etc. as required but excluding
sand cushioning and protective covering (in ordinary soil).

a1 2 core 4 sq mm m 153.00
a2 2 core 6 sq mm m 172.00
a3 2 core 10 sq mm m 180.00
a4 2 core 16 sq mm m 189.00
a5 2 core 25 sq mm m 201.00
a6 2 core 35 sq mm m 242.00
a7 2 core 50 sq mm m 287.00
a8 2 core 70 sq mm m 349.00
a9 2 core 95 sq mm m 407.00
a10 2 core 120 sq mm m 471.00
a11 2 core 150 sq mm m 563.00
a12 2 core 185 sq mm m 668.00
a13 2 core 240 sq mm m 827.00
a14 2 core 300 sq mm m 992.00
a15 2 core 400 sq mm m 1215.00

b1 3 core 4 sq mm m 161.00
b2 3 core 6 sq mm m 187.00
b3 3 core 10 sq mm m 198.00
b4 3 core 16 sq mm m 212.00
b5 3 core 25 sq mm m 245.00
b6 3 core 35 sq mm m 304.00
b7 3 core 50 sq mm m 360.00
b8 3 core 70 sq mm m 446.00
b9 3 core 95 sq mm m 531.00
b10 3 core 120 sq mm m 627.00
b11 3 core 150 sq mm m 754.00
b12 3 core 185 sq mm m 989.00
b13 3 core 240 sq mm m 1134.00
b14 3 core 300 sq mm m 1369.00
b15 3 core 400 sq mm m 1695.00

c1 3.5 core 25 sq mm m 277.00


c2 3.5 core 35 sq mm m 325.00
c3 3.5 core 50 sq mm m 403.00
c4 3.5 core 70 sq mm m 503.00
c5 3.5 core 95 sq mm m 623.00
c6 3.5 core 120 sq mm m 737.00
c7 3.5 core 150 sq mm m 851.00
c8 3.5 core 185 sq mm m 1033.00
c9 3.5 core 240 sq mm m 1296.00
c10 3.5 core 300 sq mm m 1566.00
c11 3.5 core 400 sq mm m 1946.00

d1 4 core 4 sq mm m 181.00
d2 4 core 6 sq mm m 200.00
d3 4 core 10 sq mm m 204.00
d4 4 core 16 sq mm m 238.00
d5 4 core 25 sq mm m 288.00
d6 4 core 35 sq mm m 352.00
d7 4 core 50 sq mm m 436.00
d8 4 core 70 sq mm m 548.00
d9 4 core 95 sq mm m 664.00
d10 4 core 120 sq mm m 791.00
d11 4 core 150 sq mm m 949.00
d12 4 core 185 sq mm m 1231.00
d13 4 core 240 sq mm m 1454.00
d14 4 core 300 sq mm m 1766.00
d15 4 core 400 sq mm m 2206.00
Supply & laying Aluminium power cable 1.1 KV grade in
additional position without sand cushioning & protective
covering in ordinary soil
538 Supply and laying of one number additional PVC insulated and
PVC sheathed armoured aluminium power cable of 1.1KV grade
of the following sizes in ground in the same trench in one tier
horizontal formation including widening the trench by 20 cm,
refilling the trench etc. as required but excluding sand cushioning
and protective covering (in ordinary soil)

a1 2 core 4 sq mm m 120.00
a2 2 core 6 sq mm m 139.00
a3 2 core 10 sq mm m 147.00
a4 2 core 16 sq mm m 156.00
a5 2 core 25 sq mm m 169.00
a6 2 core 35 sq mm m 203.00
a7 2 core 50 sq mm m 248.00
a8 2 core 70 sq mm m 310.00
a9 2 core 95 sq mm m 368.00
a10 2 core 120 sq mm m 433.00
a11 2 core 150 sq mm m 519.00
a12 2 core 185 sq mm m 624.00
a13 2 core 240 sq mm m 783.00
a14 2 core 300 sq mm m 948.00
a15 2 core 400 sq mm m 1171.00

b1 3 core 4 sq mm m 128.00
b2 3 core 6 sq mm m 154.00
b3 3 core 10 sq mm m 165.00
b4 3 core 16 sq mm m 180.00
b5 3 core 25 sq mm m 212.00
b6 3 core 35 sq mm m 266.00
b7 3 core 50 sq mm m 322.00
b8 3 core 70 sq mm m 408.00
b9 3 core 95 sq mm m 492.00
b10 3 core 120 sq mm m 588.00
b11 3 core 150 sq mm m 710.00
b12 3 core 185 sq mm m 854.00
b13 3 core 240 sq mm m 1090.00
b14 3 core 300 sq mm m 1325.00
b15 3 core 400 sq mm m 1651.00

c1 3.5 core 25 sq mm m 244.00


c2 3.5 core 35 sq mm m 286.00
c3 3.5 core 50 sq mm m 365.00
c4 3.5 core 70 sq mm m 464.00
c5 3.5 core 95 sq mm m 562.00
c6 3.5 core 120 sq mm m 698.00
c7 3.5 core 150 sq mm m 807.00
c8 3.5 core 185 sq mm m 989.00
c9 3.5 core 240 sq mm m 1252.00
c10 3.5 core 300 sq mm m 1522.00
c11 3.5 core 400 sq mm m 1902.00

d1 4 core 4 sq mm m 148.00
d2 4 core 6 sq mm m 168.00
d3 4 core 10 sq mm m 172.00
d4 4 core 16 sq mm m 206.00
d5 4 core 25 sq mm m 255.00
d6 4 core 35 sq mm m 314.00
d7 4 core 50 sq mm m 398.00
d8 4 core 70 sq mm m 510.00
d9 4 core 95 sq mm m 625.00
d10 4 core 120 sq mm m 752.00
d11 4 core 150 sq mm m 905.00
d12 4 core 185 sq mm m 1103.00
d13 4 core 240 sq mm m 1410.00
d14 4 core 300 sq mm m 1722.00
d15 4 core 400 sq mm m 2162.00
Supply & laying Aluminium power cable 1.1 KV grade in
original position with sand cushioning & protective covering in
hard soil
539 Supply & laying of one number PVC insulated and PVC sheathed
armoured aluminium power cable of 1.1KV grade of the
following sizes in ground including excavation of trench of size
35 x 75 cm, sand cushioning up to a height of 25cm
(80+170mm), providing protective covering with country burnt
bricks laid breadth wise, refilling the trench etc. as required (in
hard soil).

a1 2 core 4 sq mm m 396.00
a2 2 core 6 sq mm m 415.00
a3 2 core 10 sq mm m 423.00
a4 2 core 16 sq mm m 431.00
a5 2 core 25 sq mm m 444.00
a6 2 core 35 sq mm m 484.00
a7 2 core 50 sq mm m 529.00
a8 2 core 70 sq mm m 591.00
a9 2 core 95 sq mm m 650.00
a10 2 core 120 sq mm m 714.00
a11 2 core 150 sq mm m 805.00
a12 2 core 185 sq mm m 910.00
a13 2 core 240 sq mm m 1069.00
a14 2 core 300 sq mm m 1234.00
a15 2 core 400 sq mm m 1458.00

b1 3 core 4 sq mm m 404.00
b2 3 core 6 sq mm m 430.00
b3 3 core 10 sq mm m 441.00
b4 3 core 16 sq mm m 455.00
b5 3 core 25 sq mm m 488.00
b6 3 core 35 sq mm m 547.00
b7 3 core 50 sq mm m 603.00
b8 3 core 70 sq mm m 689.00
b9 3 core 95 sq mm m 773.00
b10 3 core 120 sq mm m 869.00
b11 3 core 150 sq mm m 997.00
b12 3 core 185 sq mm m 1140.00
b13 3 core 240 sq mm m 1377.00
b14 3 core 300 sq mm m 1611.00
b15 3 core 400 sq mm m 1938.00

c1 3.5 core 25 sq mm m 520.00


c2 3.5 core 35 sq mm m 568.00
c3 3.5 core 50 sq mm m 646.00
c4 3.5 core 70 sq mm m 745.00
c5 3.5 core 95 sq mm m 843.00
c6 3.5 core 120 sq mm m 979.00
c7 3.5 core 150 sq mm m 1094.00
c8 3.5 core 185 sq mm m 1276.00
c9 3.5 core 240 sq mm m 1539.00
c10 3.5 core 300 sq mm m 1809.00
c11 3.5 core 400 sq mm m 2189.00

d1 4 core 4 sq mm m 423.00
d2 4 core 6 sq mm m 443.00
d3 4 core 10 sq mm m 447.00
d4 4 core 16 sq mm m 481.00
d5 4 core 25 sq mm m 531.00
d6 4 core 35 sq mm m 595.00
d7 4 core 50 sq mm m 679.00
d8 4 core 70 sq mm m 791.00
d9 4 core 95 sq mm m 906.00
d10 4 core 120 sq mm m 1033.00
d11 4 core 150 sq mm m 1192.00
d12 4 core 185 sq mm m 1390.00
d13 4 core 240 sq mm m 1696.00
d14 4 core 300 sq mm m 2009.00
d15 4 core 400 sq mm m 2449.00
Supply & laying Aluminium power cable 1.1 KV grade in
additional position with sand cushioning & protective covering
in hard soil
540 Supply & laying of one number additional PVC insulated and
PVC sheathed armoured aluminium power cable of 1.1KV grade
of the following sizes in ground in the same trench in one tier
horizontal formation including widening the trench by 20 cm,
sand cushioning up to height of 25cm, providing protective
covering with country burnt bricks laid breadth wise, refilling the
trench etc. as required (in hard soil).

a1 2 core 4 sq mm m 273.00
a2 2 core 6 sq mm m 292.00
a3 2 core 10 sq mm m 300.00
a4 2 core 16 sq mm m 308.00
a5 2 core 25 sq mm m 321.00
a6 2 core 35 sq mm m 356.00
a7 2 core 50 sq mm m 401.00
a8 2 core 70 sq mm m 463.00
a9 2 core 95 sq mm m 521.00
a10 2 core 120 sq mm m 585.00
a11 2 core 150 sq mm m 671.00
a12 2 core 185 sq mm m 776.00
a13 2 core 240 sq mm m 935.00
a14 2 core 300 sq mm m 1100.00
a15 2 core 400 sq mm m 1324.00

b1 3 core 4 sq mm m 281.00
b2 3 core 6 sq mm m 307.00
b3 3 core 10 sq mm m 318.00
b4 3 core 16 sq mm m 332.00
b5 3 core 25 sq mm m 365.00
b6 3 core 35 sq mm m 418.00
b7 3 core 50 sq mm m 475.00
b8 3 core 70 sq mm m 560.00
b9 3 core 95 sq mm m 645.00
b10 3 core 120 sq mm m 741.00
b11 3 core 150 sq mm m 862.00
b12 3 core 185 sq mm m 1006.00
b13 3 core 240 sq mm m 1243.00
b14 3 core 300 sq mm m 1477.00
b15 3 core 400 sq mm m 1804.00

c1 3.5 core 25 sq mm m 397.00


c2 3.5 core 35 sq mm m 439.00
c3 3.5 core 50 sq mm m 517.00
c4 3.5 core 70 sq mm m 617.00
c5 3.5 core 95 sq mm m 715.00
c6 3.5 core 120 sq mm m 851.00
c7 3.5 core 150 sq mm m 960.00
c8 3.5 core 185 sq mm m 1142.00
c9 3.5 core 240 sq mm m 1405.00
c10 3.5 core 300 sq mm m 1674.00
c11 3.5 core 400 sq mm m 2055.00

d1 4 core 4 sq mm m 301.00
d2 4 core 6 sq mm m 320.00
d3 4 core 10 sq mm m 324.00
d4 4 core 16 sq mm m 358.00
d5 4 core 25 sq mm m 408.00
d6 4 core 35 sq mm m 466.00
d7 4 core 50 sq mm m 550.00
d8 4 core 70 sq mm m 663.00
d9 4 core 95 sq mm m 778.00
d10 4 core 120 sq mm m 905.00
d11 4 core 150 sq mm m 1058.00
d12 4 core 185 sq mm m 1256.00
d13 4 core 240 sq mm m 1562.00
d14 4 core 300 sq mm m 1875.00
d15 4 core 400 sq mm m 2314.00
Supply & laying Aluminium power cable 1.1 KV grade in
original position without sand cushioning & protective covering
in hard soil
541 Supply & laying of one number PVC insulated and PVC sheathed
armoured aluminium power cable of 1.1KV grade of the
following sizes in ground including excavation of trench of size
35 x 75 cm, refilling the trench etc. as required but excluding
sand cushioning and protective covering (in hard soil).

a1 2 core 4 sq mm m 174.00
a2 2 core 6 sq mm m 193.00
a3 2 core 10 sq mm m 201.00
a4 2 core 16 sq mm m 210.00
a5 2 core 25 sq mm m 222.00
a6 2 core 35 sq mm m 263.00
a7 2 core 50 sq mm m 308.00
a8 2 core 70 sq mm m 370.00
a9 2 core 95 sq mm m 428.00
a10 2 core 120 sq mm m 492.00
a11 2 core 150 sq mm m 584.00
a12 2 core 185 sq mm m 689.00
a13 2 core 240 sq mm m 848.00
a14 2 core 300 sq mm m 1013.00
a15 2 core 400 sq mm m 1236.00

b1 3 core 4 sq mm m 182.00
b2 3 core 6 sq mm m 208.00
b3 3 core 10 sq mm m 219.00
b4 3 core 16 sq mm m 233.00
b5 3 core 25 sq mm m 266.00
b6 3 core 35 sq mm m 325.00
b7 3 core 50 sq mm m 381.00
b8 3 core 70 sq mm m 467.00
b9 3 core 95 sq mm m 552.00
b10 3 core 120 sq mm m 648.00
b11 3 core 150 sq mm m 775.00
b12 3 core 185 sq mm m 919.00
b13 3 core 240 sq mm m 1155.00
b14 3 core 300 sq mm m 1390.00
b15 3 core 400 sq mm m 1716.00

c1 3.5 core 25 sq mm m 298.00


c2 3.5 core 35 sq mm m 346.00
c3 3.5 core 50 sq mm m 424.00
c4 3.5 core 70 sq mm m 524.00
c5 3.5 core 95 sq mm m 634.00
c6 3.5 core 120 sq mm m 758.00
c7 3.5 core 150 sq mm m 872.00
c8 3.5 core 185 sq mm m 1054.00
c9 3.5 core 240 sq mm m 1317.00
c10 3.5 core 300 sq mm m 1587.00
c11 3.5 core 400 sq mm m 1967.00

d1 4 core 4 sq mm m 202.00
d2 4 core 6 sq mm m 221.00
d3 4 core 10 sq mm m 225.00
d4 4 core 16 sq mm m 259.00
d5 4 core 25 sq mm m 309.00
d6 4 core 35 sq mm m 373.00
d7 4 core 50 sq mm m 457.00
d8 4 core 70 sq mm m 569.00
d9 4 core 95 sq mm m 685.00
d10 4 core 120 sq mm m 812.00
d11 4 core 150 sq mm m 970.00
d12 4 core 185 sq mm m 1168.00
d13 4 core 240 sq mm m 1475.00
d14 4 core 300 sq mm m 1787.00
d15 4 core 400 sq mm m 2227.00
Supply & laying Aluminium power cable 1.1 KV grade in
additional position without sand cushioning & protective
covering in hard soil
542 Laying of one number additional PVC insulated and PVC
sheathed armoured aluminium power cable of 1.1KV grade of
the following sizes in ground in the same trench in one tier
horizontal formation including widening the trench by 20 cm,
refilling the trench etc. as required but excluding sand cushioning
and protective covering (in hard soil)
a1 2 core 4 sq mm m 132.00
a2 2 core 6 sq mm m 151.00
a3 2 core 10 sq mm m 159.00
a4 2 core 16 sq mm m 168.00
a5 2 core 25 sq mm m 181.00
a6 2 core 35 sq mm m 215.00
a7 2 core 50 sq mm m 260.00
a8 2 core 70 sq mm m 322.00
a9 2 core 95 sq mm m 380.00
a10 2 core 120 sq mm m 445.00
a11 2 core 150 sq mm m 531.00
a12 2 core 185 sq mm m 636.00
a13 2 core 240 sq mm m 795.00
a14 2 core 300 sq mm m 960.00
a15 2 core 400 sq mm m 1183.00

b1 3 core 4 sq mm m 140.00
b2 3 core 6 sq mm m 166.00
b3 3 core 10 sq mm m 177.00
b4 3 core 16 sq mm m 192.00
b5 3 core 25 sq mm m 224.00
b6 3 core 35 sq mm m 278.00
b7 3 core 50 sq mm m 334.00
b8 3 core 70 sq mm m 420.00
b9 3 core 95 sq mm m 504.00
b10 3 core 120 sq mm m 600.00
b11 3 core 150 sq mm m 722.00
b12 3 core 185 sq mm m 866.00
b13 3 core 240 sq mm m 1102.00
b14 3 core 300 sq mm m 1337.00
b15 3 core 400 sq mm m 1663.00
c1 3.5 core 25 sq mm m 256.00
c2 3.5 core 35 sq mm m 298.00
c3 3.5 core 50 sq mm m 377.00
c4 3.5 core 70 sq mm m 476.00
c5 3.5 core 95 sq mm m 574.00
c6 3.5 core 120 sq mm m 710.00
c7 3.5 core 150 sq mm m 819.00
c8 3.5 core 185 sq mm m 1001.00
c9 3.5 core 240 sq mm m 1264.00
c10 3.5 core 300 sq mm m 1534.00
c11 3.5 core 400 sq mm m 1914.00

d1 4 core 4 sq mm m 160.00
d2 4 core 6 sq mm m 180.00
d3 4 core 10 sq mm m 184.00
d4 4 core 16 sq mm m 218.00
d5 4 core 25 sq mm m 267.00
d6 4 core 35 sq mm m 326.00
d7 4 core 50 sq mm m 410.00
d8 4 core 70 sq mm m 522.00
d9 4 core 95 sq mm m 637.00
d10 4 core 120 sq mm m 764.00
d11 4 core 150 sq mm m 917.00
d12 4 core 185 sq mm m 1115.00
d13 4 core 240 sq mm m 1422.00
d14 4 core 300 sq mm m 1734.00
d15 4 core 400 sq mm m 2174.00
Supply & laying Aluminium power cable 1.1 KV grade in
original position with sand cushioning & protective covering in
ordinary rocky soil
543 Supply & laying of one number PVC insulated and PVC sheathed
armoured aluminium power cable of 1.1KV grade of the
following sizes in ground including excavation of trench of size
35 x 75 cm, sand cushioning up to a height of 25cm
(80+170mm), providing protective covering with country burnt
bricks laid breadth wise, refilling the trench etc. as required (in
ordinary rocky - soft laterite soil).
a1 2 core 4 sq mm m 436.00
a2 2 core 6 sq mm m 454.00
a3 2 core 10 sq mm m 462.00
a4 2 core 16 sq mm m 471.00
a5 2 core 25 sq mm m 484.00
a6 2 core 35 sq mm m 524.00
a7 2 core 50 sq mm m 569.00
a8 2 core 70 sq mm m 631.00
a9 2 core 95 sq mm m 689.00
a10 2 core 120 sq mm m 753.00
a11 2 core 150 sq mm m 845.00
a12 2 core 185 sq mm m 950.00
a13 2 core 240 sq mm m 1109.00
a14 2 core 300 sq mm m 1274.00
a15 2 core 400 sq mm m 1497.00

b1 3 core 4 sq mm m 443.00
b2 3 core 6 sq mm m 469.00
b3 3 core 10 sq mm m 480.00
b4 3 core 16 sq mm m 495.00
b5 3 core 25 sq mm m 528.00
b6 3 core 35 sq mm m 586.00
b7 3 core 50 sq mm m 643.00
b8 3 core 70 sq mm m 728.00
b9 3 core 95 sq mm m 813.00
b10 3 core 120 sq mm m 909.00
b11 3 core 150 sq mm m 1036.00
b12 3 core 185 sq mm m 1180.00
b13 3 core 240 sq mm m 1416.00
b13 3 core 300 sq mm m 1651.00
b14 3 core 400 sq mm m 1978.00

c1 3.5 core 25 sq mm m 559.00


c2 3.5 core 35 sq mm m 607.00
c3 3.5 core 50 sq mm m 686.00
c4 3.5 core 70 sq mm m 785.00
c5 3.5 core 95 sq mm m 883.00
c6 3.5 core 120 sq mm m 1019.00
c7 3.5 core 150 sq mm m 1134.00
c8 3.5 core 185 sq mm m 1315.00
c9 3.5 core 240 sq mm m 1578.00
c10 3.5 core 300 sq mm m 1848.00
c11 3.5 core 400 sq mm m 2228.00

d1 4 core 4 sq mm m 463.00
d2 4 core 6 sq mm m 483.00
d3 4 core 10 sq mm m 487.00
d4 4 core 16 sq mm m 521.00
d5 4 core 25 sq mm m 571.00
d6 4 core 35 sq mm m 635.00
d7 4 core 50 sq mm m 718.00
d8 4 core 70 sq mm m 831.00
d9 4 core 95 sq mm m 946.00
d10 4 core 120 sq mm m 1073.00
d11 4 core 150 sq mm m 1232.00
d12 4 core 185 sq mm m 1429.00
d13 4 core 240 sq mm m 1736.00
d13 4 core 300 sq mm m 2049.00
d14 4 core 400 sq mm m 2488.00

Supply & laying Aluminium power cable 1.1 KV grade in


additional position with sand cushioning & protective covering
in ordinary rocky soil
544 Supply & laying of one number additional PVC insulated and
PVC sheathed armoured aluminium power cable of 1.1KV grade
of the following sizes in ground in the same trench in one tier
horizontal formation including widening the trench by 20 cm,
sand cushioning up to height of 25cm, providing protective
covering with country burnt bricks laid breadth wise, refilling the
trench etc. as required (in ordinary rocky - soft laterite soil).

a1 2 core 4 sq mm m 296.00
a2 2 core 6 sq mm m 314.00
a3 2 core 10 sq mm m 322.00
a4 2 core 16 sq mm m 331.00
a5 2 core 25 sq mm m 344.00
a6 2 core 35 sq mm m 379.00
a7 2 core 50 sq mm m 424.00
a8 2 core 70 sq mm m 486.00
a9 2 core 95 sq mm m 544.00
a10 2 core 120 sq mm m 608.00
a11 2 core 150 sq mm m 694.00
a12 2 core 185 sq mm m 799.00
a13 2 core 240 sq mm m 958.00
a14 2 core 300 sq mm m 1123.00
a15 2 core 400 sq mm m 1346.00

b1 3 core 4 sq mm m 303.00
b2 3 core 6 sq mm m 329.00
b3 3 core 10 sq mm m 341.00
b4 3 core 16 sq mm m 355.00
b5 3 core 25 sq mm m 388.00
b6 3 core 35 sq mm m 441.00
b7 3 core 50 sq mm m 497.00
b8 3 core 70 sq mm m 583.00
b9 3 core 95 sq mm m 667.00
b10 3 core 120 sq mm m 764.00
b11 3 core 150 sq mm m 885.00
b12 3 core 185 sq mm m 1029.00
b13 3 core 240 sq mm m 1265.00
b14 3 core 300 sq mm m 1500.00
b15 3 core 400 sq mm m 1827.00

c1 3.5 core 25 sq mm m 419.00


c2 3.5 core 35 sq mm m 462.00
c3 3.5 core 50 sq mm m 540.00
c4 3.5 core 70 sq mm m 640.00
c5 3.5 core 95 sq mm m 738.00
c6 3.5 core 120 sq mm m 873.00
c7 3.5 core 150 sq mm m 983.00
c8 3.5 core 185 sq mm m 1164.00
c9 3.5 core 240 sq mm m 1427.00
c10 3.5 core 300 sq mm m 1697.00
c11 3.5 core 400 sq mm m 2077.00

d1 4 core 4 sq mm m 323.00
d2 4 core 6 sq mm m 343.00
d3 4 core 10 sq mm m 347.00
d4 4 core 16 sq mm m 381.00
d5 4 core 25 sq mm m 431.00
d6 4 core 35 sq mm m 489.00
d7 4 core 50 sq mm m 573.00
d8 4 core 70 sq mm m 685.00
d9 4 core 95 sq mm m 801.00
d10 4 core 120 sq mm m 927.00
d11 4 core 150 sq mm m 1080.00
d12 4 core 185 sq mm m 1278.00
d13 4 core 240 sq mm m 1585.00
d14 4 core 300 sq mm m 1897.00
d15 4 core 400 sq mm m 2337.00
Supply & laying Aluminium power cable 1.1 KV grade in
original position without sand cushioning & protective covering
in ordinary rocky soil
545 Supply & laying of one number PVC insulated and PVC sheathed
armoured aluminium power cable of 1.1KV grade of the
following sizes in ground including excavation of trench of size
35 x 75 cm, refilling the trench etc. as required but excluding
sand cushioning and protective covering (in ordinary rocky - soft
laterite soil).

a1 2 core 4 sq mm m 214.00
a2 2 core 6 sq mm m 233.00
a3 2 core 10 sq mm m 241.00
a4 2 core 16 sq mm m 249.00
a5 2 core 25 sq mm m 262.00
a6 2 core 35 sq mm m 302.00
a7 2 core 50 sq mm m 347.00
a8 2 core 70 sq mm m 410.00
a9 2 core 95 sq mm m 468.00
a10 2 core 120 sq mm m 532.00
a11 2 core 150 sq mm m 623.00
a12 2 core 185 sq mm m 729.00
a13 2 core 240 sq mm m 887.00
a14 2 core 300 sq mm m 1052.00
a15 2 core 400 sq mm m 1276.00

b1 3 core 4 sq mm m 222.00
b2 3 core 6 sq mm m 248.00
b3 3 core 10 sq mm m 259.00
b4 3 core 16 sq mm m 273.00
b5 3 core 25 sq mm m 306.00
b6 3 core 35 sq mm m 365.00
b7 3 core 50 sq mm m 427.00
b8 3 core 70 sq mm m 514.00
b9 3 core 95 sq mm m 601.00
b10 3 core 120 sq mm m 699.00
b11 3 core 150 sq mm m 815.00
b12 3 core 185 sq mm m 959.00
b13 3 core 240 sq mm m 1195.00
b14 3 core 300 sq mm m 1429.00
b15 3 core 400 sq mm m 1756.00

c1 3.5 core 25 sq mm m 338.00


c2 3.5 core 35 sq mm m 386.00
c3 3.5 core 50 sq mm m 464.00
c4 3.5 core 70 sq mm m 563.00
c5 3.5 core 95 sq mm m 661.00
c6 3.5 core 120 sq mm m 797.00
c7 3.5 core 150 sq mm m 912.00
c8 3.5 core 185 sq mm m 1094.00
c9 3.5 core 240 sq mm m 1357.00
c10 3.5 core 300 sq mm m 1627.00
c11 3.5 core 400 sq mm m 2007.00

d1 4 core 4 sq mm m 242.00
d2 4 core 6 sq mm m 261.00
d3 4 core 10 sq mm m 265.00
d4 4 core 16 sq mm m 299.00
d5 4 core 25 sq mm m 349.00
d6 4 core 35 sq mm m 413.00
d7 4 core 50 sq mm m 497.00
d8 4 core 70 sq mm m 609.00
d9 4 core 95 sq mm m 724.00
d10 4 core 120 sq mm m 851.00
d11 4 core 150 sq mm m 1010.00
d12 4 core 185 sq mm m 1208.00
d13 4 core 240 sq mm m 1514.00
d14 4 core 300 sq mm m 1827.00
d15 4 core 400 sq mm m 2267.00
Supply & laying Aluminium power cable 1.1 KV grade in
additional position without sand cushioning & protective
covering in ordinary rocky soil
546 Laying of one number additional PVC insulated and PVC
sheathed armoured aluminium power cable of 1.1KV grade of
the following sizes in ground in the same trench in one tier
horizontal formation including widening the trench by 20 cm,
refilling the trench etc. as required but excluding sand cushioning
and protective covering (in ordinary rocky - soft laterite soil)

a1 2 core 4 sq mm m 155.00
a2 2 core 6 sq mm m 174.00
a3 2 core 10 sq mm m 182.00
a4 2 core 16 sq mm m 190.00
a5 2 core 25 sq mm m 203.00
a6 2 core 35 sq mm m 238.00
a7 2 core 50 sq mm m 283.00
a8 2 core 70 sq mm m 345.00
a9 2 core 95 sq mm m 403.00
a10 2 core 120 sq mm m 467.00
a11 2 core 150 sq mm m 553.00
a12 2 core 185 sq mm m 658.00
a13 2 core 240 sq mm m 817.00
a14 2 core 300 sq mm m 982.00
a15 2 core 400 sq mm m 1206.00

b1 3 core 4 sq mm m 163.00
b2 3 core 6 sq mm m 189.00
b3 3 core 10 sq mm m 200.00
b4 3 core 16 sq mm m 214.00
b5 3 core 25 sq mm m 247.00
b6 3 core 35 sq mm m 300.00
b7 3 core 50 sq mm m 357.00
b8 3 core 70 sq mm m 442.00
b9 3 core 95 sq mm m 527.00
b10 3 core 120 sq mm m 623.00
b11 3 core 150 sq mm m 745.00
b12 3 core 185 sq mm m 888.00
b13 3 core 240 sq mm m 1125.00
b14 3 core 300 sq mm m 1359.00
b15 3 core 400 sq mm m 1686.00

c1 3.5 core 25 sq mm m 279.00


c2 3.5 core 35 sq mm m 321.00
c3 3.5 core 50 sq mm m 399.00
c4 3.5 core 70 sq mm m 499.00
c5 3.5 core 95 sq mm m 597.00
c6 3.5 core 120 sq mm m 733.00
c7 3.5 core 150 sq mm m 842.00
c8 3.5 core 185 sq mm m 1024.00
c9 3.5 core 240 sq mm m 1287.00
c10 3.5 core 300 sq mm m 1557.00
c11 3.5 core 400 sq mm m 1937.00

d1 4 core 4 sq mm m 183.00
d2 4 core 6 sq mm m 202.00
d3 4 core 10 sq mm m 206.00
d4 4 core 16 sq mm m 240.00
d5 4 core 25 sq mm m 290.00
d6 4 core 35 sq mm m 349.00
d7 4 core 50 sq mm m 432.00
d8 4 core 70 sq mm m 545.00
d9 4 core 95 sq mm m 660.00
d10 4 core 120 sq mm m 787.00
d11 4 core 150 sq mm m 940.00
d12 4 core 185 sq mm m 1138.00
d13 4 core 240 sq mm m 1444.00
d14 4 core 300 sq mm m 1757.00
d15 4 core 400 sq mm m 2197.00

Supply & laying Aluminium power cable 1.1 KV grade through


pipe
547 Supply & laying of one number PVC insulated and PVC sheathed
armoured aluminium power cable of 1.1KV grade of the
following sizes in the existing RCC/ HUME / STONE WARE/
GI/ DWC pipe as required.

a1 2 core 4 sq mm m 112.00
a2 2 core 6 sq mm m 131.00
a3 2 core 10 sq mm m 139.00
a4 2 core 16 sq mm m 148.00
a5 2 core 25 sq mm m 160.00
a6 2 core 35 sq mm m 201.00
a7 2 core 50 sq mm m 246.00
a8 2 core 70 sq mm m 308.00
a9 2 core 95 sq mm m 366.00
a10 2 core 120 sq mm m 430.00
a11 2 core 150 sq mm m 510.00
a12 2 core 185 sq mm m 616.00
a13 2 core 240 sq mm m 774.00
a14 2 core 300 sq mm m 939.00
a15 2 core 400 sq mm m 1163.00

b1 3 core 4 sq mm m 120.00
b2 3 core 6 sq mm m 146.00
b3 3 core 10 sq mm m 157.00
b4 3 core 16 sq mm m 171.00
b5 3 core 25 sq mm m 204.00
b6 3 core 35 sq mm m 263.00
b7 3 core 50 sq mm m 319.00
b8 3 core 70 sq mm m 405.00
b9 3 core 95 sq mm m 489.00
b10 3 core 120 sq mm m 586.00
b11 3 core 150 sq mm m 702.00
b12 3 core 185 sq mm m 846.00
b13 3 core 240 sq mm m 1082.00
b14 3 core 300 sq mm m 1316.00
b15 3 core 400 sq mm m 1643.00

c1 3.5 core 25 sq mm m 236.00


c2 3.5 core 35 sq mm m 284.00
c3 3.5 core 50 sq mm m 362.00
c4 3.5 core 70 sq mm m 462.00
c5 3.5 core 95 sq mm m 560.00
c6 3.5 core 120 sq mm m 695.00
c7 3.5 core 150 sq mm m 799.00
c8 3.5 core 185 sq mm m 981.00
c9 3.5 core 240 sq mm m 1244.00
c10 3.5 core 300 sq mm m 1514.00
c11 3.5 core 400 sq mm m 1894.00

d1 4 core 4 sq mm m 140.00
d2 4 core 6 sq mm m 159.00
d3 4 core 10 sq mm m 163.00
d4 4 core 16 sq mm m 197.00
d5 4 core 25 sq mm m 247.00
d6 4 core 35 sq mm m 311.00
d7 4 core 50 sq mm m 395.00
d8 4 core 70 sq mm m 507.00
d9 4 core 95 sq mm m 623.00
d10 4 core 120 sq mm m 749.00
d11 4 core 150 sq mm m 897.00
d12 4 core 185 sq mm m 1095.00
d13 4 core 240 sq mm m 1401.00
d14 4 core 300 sq mm m 1714.00
d15 4 core 400 sq mm m 2154.00
Supply & laying Aluminium power cable 1.1 KV grade in
masonry open duct
548 Supply & laying of one No. PVC insulated and PVC sheathed
armoured aluminium power cable of 1.1 KV grade of the
following sizes in the existing masonry open duct as required.

a1 2 core 4 sq mm m 107.00
a2 2 core 6 sq mm m 125.00
a3 2 core 10 sq mm m 133.00
a4 2 core 16 sq mm m 142.00
a5 2 core 25 sq mm m 155.00
a6 2 core 35 sq mm m 192.00
a7 2 core 50 sq mm m 237.00
a8 2 core 70 sq mm m 299.00
a9 2 core 95 sq mm m 357.00
a10 2 core 120 sq mm m 421.00
a11 2 core 150 sq mm m 502.00
a12 2 core 185 sq mm m 607.00
a13 2 core 240 sq mm m 766.00
a14 2 core 300 sq mm m 931.00
a15 2 core 400 sq mm m 1154.00

b1 3 core 4 sq mm m 114.00
b2 3 core 6 sq mm m 140.00
b3 3 core 10 sq mm m 151.00
b4 3 core 16 sq mm m 166.00
b5 3 core 25 sq mm m 199.00
b6 3 core 35 sq mm m 254.00
b7 3 core 50 sq mm m 311.00
b8 3 core 70 sq mm m 397.00
b9 3 core 95 sq mm m 481.00
b10 3 core 120 sq mm m 577.00
b11 3 core 150 sq mm m 693.00
b12 3 core 185 sq mm m 837.00
b13 3 core 240 sq mm m 1073.00
b14 3 core 300 sq mm m 1308.00
b15 3 core 400 sq mm m 1635.00

c1 3.5 core 25 sq mm m 230.00


c2 3.5 core 35 sq mm m 275.00
c3 3.5 core 50 sq mm m 354.00
c4 3.5 core 70 sq mm m 453.00
c5 3.5 core 95 sq mm m 551.00
c6 3.5 core 120 sq mm m 687.00
c7 3.5 core 150 sq mm m 791.00
c8 3.5 core 185 sq mm m 972.00
c9 3.5 core 240 sq mm m 1235.00
c10 3.5 core 300 sq mm m 1505.00
c11 3.5 core 400 sq mm m 1885.00

d1 4 core 4 sq mm m 134.00
d2 4 core 6 sq mm m 154.00
d3 4 core 10 sq mm m 158.00
d4 4 core 16 sq mm m 192.00
d5 4 core 25 sq mm m 242.00
d6 4 core 35 sq mm m 303.00
d7 4 core 50 sq mm m 387.00
d8 4 core 70 sq mm m 499.00
d9 4 core 95 sq mm m 614.00
d10 4 core 120 sq mm m 741.00
d11 4 core 150 sq mm m 889.00
d12 4 core 185 sq mm m 1086.00
d13 4 core 240 sq mm m 1393.00
d14 4 core 300 sq mm m 1705.00
d15 4 core 400 sq mm m 2145.00
Supply, laying & clamping of Aluminium power cable 1.1 KV
grade
549 Supply, laying and clamping of 1 no. PVC insulated and PVC
sheathed armoured aluminium power cable, 1.1 KV grade of the
following sizes using clamps noted along with the cables, spacing
of clamps not exceeding 60cms, making good the damages ,
colour washing etc. as required.

a1 2 core 4 sq mm with factory made clamp m 120.00


a2 2 core 6 sq mm with factory made clamp m 140.00
a3 2 core 10 sq mm with factory made clamp m 148.00
a4 2 core 16 sq mm with factory made clamp m 157.00
a5 2 core 25 sq mm with factory made clamp m 177.00
a6 2 core 35 sq mm with factory made clamp m 206.00
a7 2 core 50 sq mm with factory made clamp m 257.00
a8 2 core 70 sq mm with factory made clamp m 319.00
a9 2 core 95 sq mm with factory made clamp m 377.00
a10 2 core 120 sq mm with factory made clamp m 450.00
a11 2 core 150 sq mm with factory made clamp m 530.00
a12 2 core 185 sq mm with factory made clamp m 635.00
a13 2 core 240 sq mm with fabricated MS clamps (25 x 3 mm) m 828.00
a14 2 core 300 sq mm with fabricated MS clamps (25 x 3 mm) m 993.00
a15 2 core 400 sq mm with fabricated MS clamps (25 x 3 mm) m 1216.00

b1 3 core 4 sq mm with factory made clamp m 128.00


b2 3 core 6 sq mm with factory made clamp m 155.00
b3 3 core 10 sq mm with factory made clamp m 166.00
b4 3 core 16 sq mm with factory made clamp m 180.00
b5 3 core 25 sq mm with factory made clamp m 221.00
b6 3 core 35 sq mm with factory made clamp m 268.00
b7 3 core 50 sq mm with factory made clamp m 331.00
b8 3 core 70 sq mm with factory made clamp m 417.00
b9 3 core 95 sq mm with factory made clamp m 509.00
b10 3 core 120 sq mm with factory made clamp m 605.00
b11 3 core 150 sq mm with fabricated MS clamps (25 x 3 mm) m 749.00
b12 3 core 185 sq mm with fabricated MS clamps (25 x 3 mm) m 891.00
b13 3 core 240 sq mm with fabricated MS clamps (25 x 3 mm) m 1125.00
b14 3 core 300 sq mm with fabricated MS clamps (25 x 3 mm) m 1357.00
b15 3 core 400 sq mm with fabricated MS clamps (25 x 3 mm) m 1681.00

c1 3.5 core 25 sq mm with factory made clamp m 253.00


c2 3.5 core 35 sq mm with factory made clamp m 296.00
c3 3.5 core 50 sq mm with factory made clamp m 374.00
c4 3.5 core 70 sq mm with factory made clamp m 481.00
c5 3.5 core 95 sq mm with factory made clamp m 580.00
c6 3.5 core 120 sq mm with fabricated MS clamps (25 x 3 mm) m 732.00
c7 3.5 core 150 sq mm with fabricated MS clamps (25 x 3 mm) m 845.00
c8 3.5 core 185 sq mm with fabricated MS clamps (25 x 3 mm) m 1025.00
c9 3.5 core 240 sq mm with fabricated MS clamps (25 x 3 mm) m 1285.00
c10 3.5 core 300 sq mm with fabricated MS clamps (25 x 3 mm) m 1552.00
c11 3.5 core 400 sq mm with fabricated MS clamps (25 x 3 mm) m 1929.00

d1 4 core 4 sq mm with factory made clamp m 151.00


d2 4 core 6 sq mm with factory made clamp m 170.00
d3 4 core 10 sq mm with factory made clamp m 180.00
d4 4 core 16 sq mm with factory made clamp m 214.00
d5 4 core 25 sq mm with factory made clamp m 264.00
d6 4 core 35 sq mm with factory made clamp m 329.00
d7 4 core 50 sq mm with factory made clamp m 412.00
d8 4 core 70 sq mm with factory made clamp m 527.00
d9 4 core 95 sq mm with factory made clamp m 642.00
d10 4 core 120 sq mm with fabricated MS clamps (25 x 3 mm) m 786.00
d11 4 core 150 sq mm with fabricated MS clamps (25 x 3 mm) m 950.00
d12 4 core 185 sq mm with fabricated MS clamps (25 x 3 mm) m 1148.00
d13 4 core 240 sq mm with fabricated MS clamps (25 x 3 mm) m 1455.00
d14 4 core 300 sq mm with fabricated MS clamps (25 x 3 mm) m 1767.00
d15 4 core 400 sq mm with fabricated MS clamps (25 x 3 mm) m 2207.00
Supply & laying copper power cable 1.1 KV grade
Supply & laying of copper power cable 1.1 KV grade in original
position with sand cushioning & protective covering in ordinary
soil
550 Supply & laying of one number PVC insulated and PVC sheathed
armoured copper power cable of 1.1KV grade of the following
sizes in ground including excavation of trench of size 35 x 75 cm,
sand cushioning up to a height of 25cm (80+170mm), providing
protective covering with country burnt bricks laid breadth wise,
refilling the trench etc. as required (in ordinary soil).
a1 2 core 4 sq mm m 460.00
a2 2 core 6 sq mm m 513.00
a3 2 core 10 sq mm m 625.00
a4 2 core 16 sq mm m 751.00

b1 3 core 4 sq mm m 507.00
b2 3 core 6 sq mm m 582.00
b3 3 core 10 sq mm m 750.00
b4 3 core 16 sq mm m 919.00
b5 3 core 25 sq mm m 1359.00
b6 3 core 35 sq mm m 1753.00
b7 3 core 50 sq mm m 2261.00
b8 3 core 70 sq mm m 3041.00
b9 3 core 95 sq mm m 4103.00
b10 3 core 120 sq mm m 5072.00
b11 3 core 150 sq mm m 6183.00
b12 3 core 185 sq mm m 7611.00
b13 3 core 240 sq mm m 9920.00
b14 3 core 300 sq mm m 12197.00
b15 3 core 400 sq mm m 15598.00

c1 3.5 core 25 sq mm m 1564.00


c2 3.5 core 35 sq mm m 1967.00
c3 3.5 core 50 sq mm m 2597.00
c4 3.5 core 70 sq mm m 3501.00
c5 3.5 core 95 sq mm m 4731.00
c6 3.5 core 120 sq mm m 5965.00
c7 3.5 core 150 sq mm m 7082.00
c8 3.5 core 185 sq mm m 8858.00
c9 3.5 core 240 sq mm m 11348.00
c10 3.5 core 300 sq mm m 14132.00
c11 3.5 core 400 sq mm m 18004.00

d1 4 core 4 sq mm m 560.00
d2 4 core 6 sq mm m 659.00
d3 4 core 10 sq mm m 855.00
d4 4 core 16 sq mm m 1114.00
d5 4 core 25 sq mm m 1698.00
d6 4 core 35 sq mm m 2217.00
d7 4 core 50 sq mm m 2892.00
d8 4 core 70 sq mm m 3957.00
Supply & laying of copper power cable 1.1 KV grade in
additional position with sand cushioning & protective covering
in ordinary soil
551 Supply & laying of one number additional PVC insulated and
PVC sheathed armoured copper power cable of 1.1KV grade of
the following sizes in ground in the same trench in one tier
horizontal formation including widening the trench by 20 cm,
sand cushioning up to height of 25cm, providing protective
covering with country burnt bricks laid breadth wise, refilling the
trench etc. as required (in ordinary soil).

a1 2 core 4 sq mm m 346.00
a2 2 core 6 sq mm m 399.00
a3 2 core 10 sq mm m 511.00
a4 2 core 16 sq mm m 637.00

b1 3 core 4 sq mm m 393.00
b2 3 core 6 sq mm m 468.00
b3 3 core 10 sq mm m 636.00
b4 3 core 16 sq mm m 805.00
b5 3 core 25 sq mm m 1245.00
b6 3 core 35 sq mm m 1633.00
b7 3 core 50 sq mm m 2141.00
b8 3 core 70 sq mm m 2921.00
b9 3 core 95 sq mm m 3983.00
b10 3 core 120 sq mm m 4952.00
b11 3 core 150 sq mm m 6058.00
b12 3 core 185 sq mm m 7486.00
b13 3 core 240 sq mm m 9795.00
b13 3 core 300 sq mm m 12072.00
b14 3 core 400 sq mm m 15473.00

c1 3.5 core 25 sq mm m 1450.00


c2 3.5 core 35 sq mm m 1848.00
c3 3.5 core 50 sq mm m 2477.00
c4 3.5 core 70 sq mm m 3382.00
c5 3.5 core 95 sq mm m 4612.00
c6 3.5 core 120 sq mm m 5845.00
c7 3.5 core 150 sq mm m 6957.00
c8 3.5 core 185 sq mm m 8733.00
c9 3.5 core 240 sq mm m 11223.00
c10 3.5 core 300 sq mm m 14007.00
c11 3.5 core 400 sq mm m 17879.00
d1 4 core 4 sq mm m 446.00
d2 4 core 6 sq mm m 545.00
d3 4 core 10 sq mm m 741.00
d4 4 core 16 sq mm m 1000.00
d5 4 core 25 sq mm m 1584.00
d6 4 core 35 sq mm m 2097.00
d7 4 core 50 sq mm m 2773.00
d8 4 core 70 sq mm m 3837.00
Supply & laying of copper power cable 1.1 KV grade in original
position without sand cushioning & protective covering in
ordinary soil
552 Supply & laying of one number PVC insulated and PVC sheathed
armoured copper power cable of 1.1KV grade of the following
sizes in ground including excavation of trench of size 35 x 75 cm,
refilling the trench etc. as required but excluding sand cushioning
and protective covering (in ordinary soil).

a1 2 core 4 sq mm m 238.00
a2 2 core 6 sq mm m 292.00
a3 2 core 10 sq mm m 403.00
a4 2 core 16 sq mm m 530.00

b1 3 core 4 sq mm m 285.00
b2 3 core 6 sq mm m 360.00
b3 3 core 10 sq mm m 528.00
b4 3 core 16 sq mm m 698.00
b5 3 core 25 sq mm m 1137.00
b6 3 core 35 sq mm m 1531.00
b7 3 core 50 sq mm m 2039.00
b8 3 core 70 sq mm m 2819.00
b9 3 core 95 sq mm m 3881.00
b10 3 core 120 sq mm m 4850.00
b11 3 core 150 sq mm m 5961.00
b12 3 core 185 sq mm m 7390.00
b13 3 core 240 sq mm m 9699.00
b14 3 core 300 sq mm m 11975.00
b15 3 core 400 sq mm m 15377.00

c1 3.5 core 25 sq mm m 1343.00


c2 3.5 core 35 sq mm m 1746.00
c3 3.5 core 50 sq mm m 2375.00
c4 3.5 core 70 sq mm m 3280.00
c5 3.5 core 95 sq mm m 4510.00
c6 3.5 core 120 sq mm m 5743.00
c7 3.5 core 150 sq mm m 6861.00
c8 3.5 core 185 sq mm m 8637.00
c9 3.5 core 240 sq mm m 11127.00
c10 3.5 core 300 sq mm m 13911.00
c11 3.5 core 400 sq mm m 17783.00

d1 4 core 4 sq mm m 339.00
d2 4 core 6 sq mm m 437.00
d3 4 core 10 sq mm m 633.00
d4 4 core 16 sq mm m 892.00
d5 4 core 25 sq mm m 1476.00
d6 4 core 35 sq mm m 1995.00
d7 4 core 50 sq mm m 2670.00
d8 4 core 70 sq mm m 3735.00
Supply & laying of copper power cable 1.1 KV grade in
additional position without sand cushioning & protective
covering in ordinary soil
553 Laying of one number additional PVC insulated and PVC
sheathed armoured copper power cable of 1.1KV grade of the
following sizes in ground in the same trench in one tier horizontal
formation including widening the trench by 20 cm, refilling the
trench etc. as required but excluding sand cushioning and
protective covering (in ordinary soil)

a1 2 core 4 sq mm m 227.00
a2 2 core 6 sq mm m 281.00
a3 2 core 10 sq mm m 392.00
a4 2 core 16 sq mm m 519.00

b1 3 core 4 sq mm m 274.00
b2 3 core 6 sq mm m 350.00
b3 3 core 10 sq mm m 518.00
b4 3 core 16 sq mm m 687.00
b5 3 core 25 sq mm m 1127.00
b6 3 core 35 sq mm m 1521.00
b7 3 core 50 sq mm m 2028.00
b8 3 core 70 sq mm m 2808.00
b9 3 core 95 sq mm m 3870.00
b10 3 core 120 sq mm m 4839.00
b11 3 core 150 sq mm m 5950.00
b12 3 core 185 sq mm m 7379.00
b13 3 core 240 sq mm m 9688.00
b14 3 core 300 sq mm m 11964.00
b15 3 core 400 sq mm m 15366.00

c1 3.5 core 25 sq mm m 1332.00


c2 3.5 core 35 sq mm m 1735.00
c3 3.5 core 50 sq mm m 2364.00
c4 3.5 core 70 sq mm m 3269.00
c5 3.5 core 95 sq mm m 4499.00
c6 3.5 core 120 sq mm m 5732.00
c7 3.5 core 150 sq mm m 6850.00
c8 3.5 core 185 sq mm m 8626.00
c9 3.5 core 240 sq mm m 11116.00
c10 3.5 core 300 sq mm m 13900.00
c11 3.5 core 400 sq mm m 17772.00

d1 4 core 4 sq mm m 328.00
d2 4 core 6 sq mm m 427.00
d3 4 core 10 sq mm m 623.00
d4 4 core 16 sq mm m 882.00
d5 4 core 25 sq mm m 1466.00
d6 4 core 35 sq mm m 1984.00
d7 4 core 50 sq mm m 2660.00
d8 4 core 70 sq mm m 3724.00
Supply & laying of copper power cable 1.1 KV grade in original
position with sand cushioning & protective covering in hard soil

554 Supply & laying of one number PVC insulated and PVC sheathed
armoured copper power cable of 1.1KV grade of the following
sizes in ground including excavation of trench of size 35 x 75 cm,
sand cushioning up to a height of 25cm (80+170mm), providing
protective covering with country burnt bricks laid breadth wise,
refilling the trench etc. as required (in hard soil).

a1 2 core 4 sq mm m 481.00
a2 2 core 6 sq mm m 534.00
a3 2 core 10 sq mm m 646.00
a4 2 core 16 sq mm m 772.00

b1 3 core 4 sq mm m 528.00
b2 3 core 6 sq mm m 603.00
b3 3 core 10 sq mm m 771.00
b4 3 core 16 sq mm m 940.00
b5 3 core 25 sq mm m 1380.00
b6 3 core 35 sq mm m 1774.00
b7 3 core 50 sq mm m 2282.00
b8 3 core 70 sq mm m 3062.00
b9 3 core 95 sq mm m 4124.00
b10 3 core 120 sq mm m 5093.00
b11 3 core 150 sq mm m 6204.00
b12 3 core 185 sq mm m 7632.00
b13 3 core 240 sq mm m 9941.00
b13 3 core 300 sq mm m 12218.00
b14 3 core 400 sq mm m 15619.00

c1 3.5 core 25 sq mm m 1585.00


c2 3.5 core 35 sq mm m 1988.00
c3 3.5 core 50 sq mm m 2618.00
c4 3.5 core 70 sq mm m 3522.00
c5 3.5 core 95 sq mm m 4752.00
c6 3.5 core 120 sq mm m 5986.00
c7 3.5 core 150 sq mm m 7103.00
c8 3.5 core 185 sq mm m 8879.00
c9 3.5 core 240 sq mm m 11369.00
c10 3.5 core 300 sq mm m 14153.00
c11 3.5 core 400 sq mm m 18025.00

d1 4 core 4 sq mm m 581.00
d2 4 core 6 sq mm m 680.00
d3 4 core 10 sq mm m 876.00
d4 4 core 16 sq mm m 1135.00
d5 4 core 25 sq mm m 1719.00
d6 4 core 35 sq mm m 2238.00
d7 4 core 50 sq mm m 2913.00
d8 4 core 70 sq mm m 3978.00
Supply & laying of copper power cable 1.1 KV grade in
additional position with sand cushioning & protective covering
in hard soil
555 Supply & laying of one number additional PVC insulated and
PVC sheathed armoured copper power cable of 1.1KV grade of
the following sizes in ground in the same trench in one tier
horizontal formation including widening the trench by 20 cm,
sand cushioning up to height of 25cm, providing protective
covering with country burnt bricks laid breadth wise, refilling the
trench etc. as required (in hard soil).

a1 2 core 4 sq mm m 358.00
a2 2 core 6 sq mm m 411.00
a3 2 core 10 sq mm m 523.00
a4 2 core 16 sq mm m 649.00

b1 3 core 4 sq mm m 405.00
b2 3 core 6 sq mm m 480.00
b3 3 core 10 sq mm m 648.00
b4 3 core 16 sq mm m 817.00
b5 3 core 25 sq mm m 1257.00
b6 3 core 35 sq mm m 1646.00
b7 3 core 50 sq mm m 2153.00
b8 3 core 70 sq mm m 2933.00
b9 3 core 95 sq mm m 3995.00
b10 3 core 120 sq mm m 4964.00
b11 3 core 150 sq mm m 6070.00
b12 3 core 185 sq mm m 7498.00
b13 3 core 240 sq mm m 9807.00
b14 3 core 300 sq mm m 12084.00
b15 3 core 400 sq mm m 15485.00

c1 3.5 core 25 sq mm m 1462.00


c2 3.5 core 35 sq mm m 1860.00
c3 3.5 core 50 sq mm m 2489.00
c4 3.5 core 70 sq mm m 3394.00
c5 3.5 core 95 sq mm m 4624.00
c6 3.5 core 120 sq mm m 5857.00
c7 3.5 core 150 sq mm m 6969.00
c8 3.5 core 185 sq mm m 8745.00
c9 3.5 core 240 sq mm m 11235.00
c10 3.5 core 300 sq mm m 14019.00
c11 3.5 core 400 sq mm m 17891.00

d1 4 core 4 sq mm m 458.00
d2 4 core 6 sq mm m 557.00
d3 4 core 10 sq mm m 753.00
d4 4 core 16 sq mm m 1012.00
d5 4 core 25 sq mm m 1596.00
d6 4 core 35 sq mm m 2109.00
d7 4 core 50 sq mm m 2785.00
d8 4 core 70 sq mm m 3849.00
Supply & laying of copper power cable 1.1 KV grade in original
position without sand cushioning & protective covering in hard
soil
556 Supply & laying of one number PVC insulated and PVC sheathed
armoured copper power cable of 1.1KV grade of the following
sizes in ground including excavation of trench of size 35 x 75 cm,
refilling the trench etc. as required but excluding sand cushioning
and protective covering (in hard soil).

a1 2 core 4 sq mm m 259.00
a2 2 core 6 sq mm m 313.00
a3 2 core 10 sq mm m 424.00
a4 2 core 16 sq mm m 551.00

b1 3 core 4 sq mm m 306.00
b2 3 core 6 sq mm m 381.00
b3 3 core 10 sq mm m 549.00
b4 3 core 16 sq mm m 719.00
b5 3 core 25 sq mm m 1159.00
b6 3 core 35 sq mm m 1552.00
b7 3 core 50 sq mm m 2060.00
b8 3 core 70 sq mm m 2840.00
b9 3 core 95 sq mm m 3902.00
b10 3 core 120 sq mm m 4871.00
b11 3 core 150 sq mm m 5982.00
b12 3 core 185 sq mm m 7411.00
b13 3 core 240 sq mm m 9720.00
b13 3 core 300 sq mm m 11996.00
b14 3 core 400 sq mm m 15398.00

c1 3.5 core 25 sq mm m 1364.00


c2 3.5 core 35 sq mm m 1767.00
c3 3.5 core 50 sq mm m 2396.00
c4 3.5 core 70 sq mm m 3301.00
c5 3.5 core 95 sq mm m 4531.00
c6 3.5 core 120 sq mm m 5764.00
c7 3.5 core 150 sq mm m 6882.00
c8 3.5 core 185 sq mm m 8658.00
c9 3.5 core 240 sq mm m 11148.00
c10 3.5 core 300 sq mm m 13932.00
c11 3.5 core 400 sq mm m 17804.00

d1 4 core 4 sq mm m 360.00
d2 4 core 6 sq mm m 458.00
d3 4 core 10 sq mm m 654.00
d4 4 core 16 sq mm m 913.00
d5 4 core 25 sq mm m 1497.00
d6 4 core 35 sq mm m 2016.00
d7 4 core 50 sq mm m 2691.00
d8 4 core 70 sq mm m 3756.00
Supply & laying of copper power cable 1.1 KV grade in
additional position without sand cushioning & protective
covering in hard soil
557 Laying of one number additional PVC insulated and PVC
sheathed armoured copper power cable of 1.1KV grade of the
following sizes in ground in the same trench in one tier horizontal
formation including widening the trench by 20 cm, refilling the
trench etc. as required but excluding sand cushioning and
protective covering (in hard soil)

a1 2 core 4 sq mm m 239.00
a2 2 core 6 sq mm m 293.00
a3 2 core 10 sq mm m 386.00
a4 2 core 16 sq mm m 531.00

b1 3 core 4 sq mm m 286.00
b2 3 core 6 sq mm m 362.00
b3 3 core 10 sq mm m 530.00
b4 3 core 16 sq mm m 699.00
b5 3 core 25 sq mm m 1139.00
b6 3 core 35 sq mm m 1533.00
b7 3 core 50 sq mm m 2040.00
b8 3 core 70 sq mm m 2821.00
b9 3 core 95 sq mm m 3882.00
b10 3 core 120 sq mm m 4851.00
b11 3 core 150 sq mm m 5962.00
b12 3 core 185 sq mm m 7391.00
b13 3 core 240 sq mm m 9700.00
b14 3 core 300 sq mm m 11976.00
b15 3 core 400 sq mm m 15378.00

c1 3.5 core 25 sq mm m 1344.00


c2 3.5 core 35 sq mm m 1747.00
c3 3.5 core 50 sq mm m 2376.00
c4 3.5 core 70 sq mm m 3281.00
c5 3.5 core 95 sq mm m 4511.00
c6 3.5 core 120 sq mm m 5744.00
c7 3.5 core 150 sq mm m 6862.00
c8 3.5 core 185 sq mm m 8638.00
c9 3.5 core 240 sq mm m 11128.00
c10 3.5 core 300 sq mm m 13912.00
c11 3.5 core 400 sq mm m 17784.00

d1 4 core 4 sq mm m 340.00
d2 4 core 6 sq mm m 439.00
d3 4 core 10 sq mm m 635.00
d4 4 core 16 sq mm m 894.00
d5 4 core 25 sq mm m 1478.00
d6 4 core 35 sq mm m 1996.00
d7 4 core 50 sq mm m 2672.00
d8 4 core 70 sq mm m 3736.00
Supply & laying of copper power cable 1.1 KV grade in original
position with sand cushioning & protective covering in ordinary
rocky soil
558 Supply & laying of one number PVC insulated and PVC sheathed
armoured copper power cable of 1.1KV grade of the following
sizes in ground including excavation of trench of size 35 x 75 cm,
sand cushioning up to a height of 25cm (80+170mm), providing
protective covering with country burnt bricks laid breadth wise,
refilling the trench etc. as required (in ordinary rocky - soft
laterite soil).

a1 2 core 4 sq mm m 520.00
a2 2 core 6 sq mm m 574.00
a3 2 core 10 sq mm m 686.00
a4 2 core 16 sq mm m 812.00

b1 3 core 4 sq mm m 568.00
b2 3 core 6 sq mm m 643.00
b3 3 core 10 sq mm m 811.00
b4 3 core 16 sq mm m 980.00
b5 3 core 25 sq mm m 1420.00
b6 3 core 35 sq mm m 1814.00
b7 3 core 50 sq mm m 2322.00
b8 3 core 70 sq mm m 3102.00
b9 3 core 95 sq mm m 4164.00
b10 3 core 120 sq mm m 5132.00
b11 3 core 150 sq mm m 6244.00
b12 3 core 185 sq mm m 7672.00
b13 3 core 240 sq mm m 9981.00
b14 3 core 300 sq mm m 12258.00
b15 3 core 400 sq mm m 15659.00

c1 3.5 core 25 sq mm m 1625.00


c2 3.5 core 35 sq mm m 2028.00
c3 3.5 core 50 sq mm m 2657.00
c4 3.5 core 70 sq mm m 3562.00
c5 3.5 core 95 sq mm m 4792.00
c6 3.5 core 120 sq mm m 6025.00
c7 3.5 core 150 sq mm m 7143.00
c8 3.5 core 185 sq mm m 8919.00
c9 3.5 core 240 sq mm m 11409.00
c10 3.5 core 300 sq mm m 14193.00
c11 3.5 core 400 sq mm m 18065.00

d1 4 core 4 sq mm m 621.00
d2 4 core 6 sq mm m 720.00
d3 4 core 10 sq mm m 916.00
d4 4 core 16 sq mm m 1175.00
d5 4 core 25 sq mm m 1759.00
d6 4 core 35 sq mm m 2277.00
d7 4 core 50 sq mm m 2953.00
d8 4 core 70 sq mm m 4018.00
Supply & laying of copper power cable 1.1 KV grade in
additional position with sand cushioning & protective covering
in ordinary rocky soil
559 Supply & laying of one number additional PVC insulated and
PVC sheathed armoured copper power cable of 1.1KV grade of
the following sizes in ground in the same trench in one tier
horizontal formation including widening the trench by 20 cm,
sand cushioning up to height of 25cm, providing protective
covering with country burnt bricks laid breadth wise, refilling the
trench etc. as required (in ordinary rocky - soft laterite soil).

a1 2 core 4 sq mm m 380.00
a2 2 core 6 sq mm m 434.00
a3 2 core 10 sq mm m 546.00
a4 2 core 16 sq mm m 672.00

b1 3 core 4 sq mm m 428.00
b2 3 core 6 sq mm m 503.00
b3 3 core 10 sq mm m 671.00
b4 3 core 16 sq mm m 840.00
b5 3 core 25 sq mm m 1280.00
b6 3 core 35 sq mm m 1668.00
b7 3 core 50 sq mm m 2176.00
b8 3 core 70 sq mm m 2956.00
b9 3 core 95 sq mm m 4018.00
b10 3 core 120 sq mm m 4987.00
b11 3 core 150 sq mm m 6092.00
b12 3 core 185 sq mm m 7521.00
b13 3 core 240 sq mm m 9830.00
b14 3 core 300 sq mm m 12106.00
b15 3 core 400 sq mm m 15508.00

c1 3.5 core 25 sq mm m 1485.00


c2 3.5 core 35 sq mm m 1883.00
c3 3.5 core 50 sq mm m 2512.00
c4 3.5 core 70 sq mm m 3417.00
c5 3.5 core 95 sq mm m 4646.00
c6 3.5 core 120 sq mm m 5880.00
c7 3.5 core 150 sq mm m 6992.00
c8 3.5 core 185 sq mm m 8768.00
c9 3.5 core 240 sq mm m 11258.00
c10 3.5 core 300 sq mm m 14042.00
c11 3.5 core 400 sq mm m 17914.00

d1 4 core 4 sq mm m 481.00
d2 4 core 6 sq mm m 580.00
d3 4 core 10 sq mm m 776.00
d4 4 core 16 sq mm m 1035.00
d5 4 core 25 sq mm m 1619.00
d6 4 core 35 sq mm m 2132.00
d7 4 core 50 sq mm m 2807.00
d8 4 core 70 sq mm m 3872.00
Supply & laying of copper power cable 1.1 KV grade in original
position without sand cushioning & protective covering in
ordinary rocky soil
560 Supply & laying of one number PVC insulated and PVC sheathed
armoured copper power cable of 1.1KV grade of the following
sizes in ground including excavation of trench of size 35 x 75 cm,
refilling the trench etc. as required but excluding sand cushioning
and protective covering (in ordinary rocky - soft laterite soil).

a1 2 core 4 sq mm m 299.00
a2 2 core 6 sq mm m 352.00
a3 2 core 10 sq mm m 464.00
a4 2 core 16 sq mm m 590.00

b1 3 core 4 sq mm m 346.00
b2 3 core 6 sq mm m 421.00
b3 3 core 10 sq mm m 589.00
b4 3 core 16 sq mm m 758.00
b5 3 core 25 sq mm m 1198.00
b6 3 core 35 sq mm m 1592.00
b7 3 core 50 sq mm m 2100.00
b8 3 core 70 sq mm m 2880.00
b9 3 core 95 sq mm m 3942.00
b10 3 core 120 sq mm m 4911.00
b11 3 core 150 sq mm m 6022.00
b12 3 core 185 sq mm m 7450.00
b13 3 core 240 sq mm m 9759.00
b13 3 core 300 sq mm m 12036.00
b14 3 core 400 sq mm m 15437.00

c1 3.5 core 25 sq mm m 1403.00


c2 3.5 core 35 sq mm m 1806.00
c3 3.5 core 50 sq mm m 2436.00
c4 3.5 core 70 sq mm m 3340.00
c5 3.5 core 95 sq mm m 4570.00
c6 3.5 core 120 sq mm m 5804.00
c7 3.5 core 150 sq mm m 6921.00
c8 3.5 core 185 sq mm m 8697.00
c9 3.5 core 240 sq mm m 11188.00
c10 3.5 core 300 sq mm m 13971.00
c11 3.5 core 400 sq mm m 17843.00

d1 4 core 4 sq mm m 399.00
d2 4 core 6 sq mm m 498.00
d3 4 core 10 sq mm m 694.00
d4 4 core 16 sq mm m 953.00
d5 4 core 25 sq mm m 1537.00
d6 4 core 35 sq mm m 2056.00
d7 4 core 50 sq mm m 2731.00
d8 4 core 70 sq mm m 3796.00
Supply & laying of copper power cable 1.1 KV grade in
additional position without sand cushioning & protective
covering in ordinary rocky soil
561 Laying of one number additional PVC insulated and PVC
sheathed armoured copper power cable of 1.1KV grade of the
following sizes in ground in the same trench in one tier horizontal
formation including widening the trench by 20 cm, refilling the
trench etc. as required but excluding sand cushioning and
protective covering (in ordinary rocky - soft laterite soil)

a1 2 core 4 sq mm m 262.00
a2 2 core 6 sq mm m 316.00
a3 2 core 10 sq mm m 427.00
a4 2 core 16 sq mm m 554.00

b1 3 core 4 sq mm m 309.00
b2 3 core 6 sq mm m 384.00
b3 3 core 10 sq mm m 552.00
b4 3 core 16 sq mm m 722.00
b5 3 core 25 sq mm m 1161.00
b6 3 core 35 sq mm m 1555.00
b7 3 core 50 sq mm m 2063.00
b8 3 core 70 sq mm m 2843.00
b9 3 core 95 sq mm m 3905.00
b10 3 core 120 sq mm m 4874.00
b11 3 core 150 sq mm m 5985.00
b12 3 core 185 sq mm m 7414.00
b13 3 core 240 sq mm m 9722.00
b14 3 core 300 sq mm m 11999.00
b15 3 core 400 sq mm m 15400.00

c1 3.5 core 25 sq mm m 1367.00


c2 3.5 core 35 sq mm m 1770.00
c3 3.5 core 50 sq mm m 2399.00
c4 3.5 core 70 sq mm m 3304.00
c5 3.5 core 95 sq mm m 4533.00
c6 3.5 core 120 sq mm m 5767.00
c7 3.5 core 150 sq mm m 6884.00
c8 3.5 core 185 sq mm m 8661.00
c9 3.5 core 240 sq mm m 11151.00
c10 3.5 core 300 sq mm m 13934.00
c11 3.5 core 400 sq mm m 17807.00

d1 4 core 4 sq mm m 363.00
d2 4 core 6 sq mm m 461.00
d3 4 core 10 sq mm m 657.00
d4 4 core 16 sq mm m 916.00
d5 4 core 25 sq mm m 1500.00
d6 4 core 35 sq mm m 2019.00
d7 4 core 50 sq mm m 2694.00
d8 4 core 70 sq mm m 3759.00
Supply & laying of copper power cable 1.1 KV grade through
existing pipe
562 Supply & laying of one number PVC insulated and PVC sheathed
armoured copper power cable of 1.1KV grade of the following
sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC
pipe as required.

a1 2 core 4 sq mm m 197.00
a2 2 core 6 sq mm m 251.00
a3 2 core 10 sq mm m 362.00
a4 2 core 16 sq mm m 489.00

b1 3 core 4 sq mm m 244.00
b2 3 core 6 sq mm m 319.00
b3 3 core 10 sq mm m 487.00
b4 3 core 16 sq mm m 656.00
b5 3 core 25 sq mm m 1096.00
b6 3 core 35 sq mm m 1490.00
b7 3 core 50 sq mm m 1998.00
b8 3 core 70 sq mm m 2778.00
b9 3 core 95 sq mm m 3840.00
b10 3 core 120 sq mm m 4809.00
b11 3 core 150 sq mm m 5909.00
b12 3 core 185 sq mm m 7337.00
b13 3 core 240 sq mm m 9646.00
b14 3 core 300 sq mm m 11923.00
b15 3 core 400 sq mm m 15324.00

c1 3.5 core 25 sq mm m 1302.00


c2 3.5 core 35 sq mm m 1705.00
c3 3.5 core 50 sq mm m 2334.00
c4 3.5 core 70 sq mm m 3239.00
c5 3.5 core 95 sq mm m 4468.00
c6 3.5 core 120 sq mm m 5702.00
c7 3.5 core 150 sq mm m 6808.00
c8 3.5 core 185 sq mm m 8584.00
c9 3.5 core 240 sq mm m 11075.00
c10 3.5 core 300 sq mm m 13858.00
c11 3.5 core 400 sq mm m 17730.00
d1 4 core 4 sq mm m 298.00
d2 4 core 6 sq mm m 396.00
d3 4 core 10 sq mm m 592.00
d4 4 core 16 sq mm m 851.00
d5 4 core 25 sq mm m 1435.00
d6 4 core 35 sq mm m 1954.00
d7 4 core 50 sq mm m 2629.00
d8 4 core 70 sq mm m 3694.00
Supply & laying of copper power cable 1.1 KV grade in the
masonry open duct
563 Supply & laying of one No. PVC insulated and PVC sheathed
armoured copper power cable of 1.1 KV grade of the following
sizes in the existing masonry open duct as required.

a1 2 core 4 sq mm m 191.00
a2 2 core 6 sq mm m 245.00
a3 2 core 10 sq mm m 356.00
a4 2 core 16 sq mm m 483.00

b1 3 core 4 sq mm m 238.00
b2 3 core 6 sq mm m 314.00
b3 3 core 10 sq mm m 482.00
b4 3 core 16 sq mm m 651.00
b5 3 core 25 sq mm m 1091.00
b6 3 core 35 sq mm m 1482.00
b7 3 core 50 sq mm m 1990.00
b8 3 core 70 sq mm m 2770.00
b9 3 core 95 sq mm m 3832.00
b10 3 core 120 sq mm m 4800.00
b11 3 core 150 sq mm m 5901.00
b12 3 core 185 sq mm m 7329.00
b13 3 core 240 sq mm m 9638.00
b14 3 core 300 sq mm m 11914.00
b15 3 core 400 sq mm m 15316.00

c1 3.5 core 25 sq mm m 1296.00


c2 3.5 core 35 sq mm m 1696.00
c3 3.5 core 50 sq mm m 2326.00
c4 3.5 core 70 sq mm m 3230.00
c5 3.5 core 95 sq mm m 4460.00
c6 3.5 core 120 sq mm m 5693.00
c7 3.5 core 150 sq mm m 6800.00
c8 3.5 core 185 sq mm m 8576.00
c9 3.5 core 240 sq mm m 11066.00
c10 3.5 core 300 sq mm m 13850.00
c11 3.5 core 400 sq mm m 17722.00

d1 4 core 4 sq mm m 292.00
d2 4 core 6 sq mm m 391.00
d3 4 core 10 sq mm m 587.00
d4 4 core 16 sq mm m 846.00
d5 4 core 25 sq mm m 1430.00
d6 4 core 35 sq mm m 1945.00
d7 4 core 50 sq mm m 2621.00
d8 4 core 70 sq mm m 3686.00
Supply, laying & clamping of copper power cable 1.1 KV grade

564 Supply, laying and clamping of 1 no. PVC insulated and PVC
sheathed armoured copper power cable, 1.1 KV grade of the
following sizes using clamps noted along with the cables, spacing
of clamps not exceeding 60cms, making good the damages ,
colour washing etc. as required.

a1 2 core 4 sq mm m 205.00
a2 2 core 6 sq mm m 260.00
a3 2 core 10 sq mm m 371.00
a4 2 core 16 sq mm m 498.00

b1 3 core 4 sq mm m 252.00
b2 3 core 6 sq mm m 328.00
b3 3 core 10 sq mm m 496.00
b4 3 core 16 sq mm m 665.00
b5 3 core 25 sq mm m 1113.00
b6 3 core 35 sq mm m 1496.00
b7 3 core 50 sq mm m 2010.00
b8 3 core 70 sq mm m 2790.00
b9 3 core 95 sq mm m 3860.00
b10 3 core 120 sq mm m 4829.00
b11 3 core 150 sq mm m 5907.00
b12 3 core 185 sq mm m 7322.00
b13 3 core 240 sq mm m 9609.00
b14 3 core 300 sq mm m 11864.00
b15 3 core 400 sq mm m 15233.00

c1 3.5 core 25 sq mm m 1318.00


c2 3.5 core 35 sq mm m 1717.00
c3 3.5 core 50 sq mm m 2346.00
c4 3.5 core 70 sq mm m 3258.00
c5 3.5 core 95 sq mm m 4488.00
c6 3.5 core 120 sq mm m 5738.00
c7 3.5 core 150 sq mm m 6797.00
c8 3.5 core 185 sq mm m 8556.00
c9 3.5 core 240 sq mm m 11023.00
c10 3.5 core 300 sq mm m 13780.00
c11 3.5 core 400 sq mm m 17616.00

d1 4 core 4 sq mm m 307.00
d2 4 core 6 sq mm m 405.00
d3 4 core 10 sq mm m 609.00
d4 4 core 16 sq mm m 868.00
d5 4 core 25 sq mm m 1452.00
d6 4 core 35 sq mm m 1971.00
d7 4 core 50 sq mm m 2647.00
d8 4 core 70 sq mm m 3714.00

Laying of control cable in original position with sand


cushioning & protective covering (in ordinary soil)
570 Laying of one number PVC insulated and PVC sheathed
armoured control cable of 1.1KV grade of the following sizes in
ground including excavation of trench of size 35 x 75 cm, sand
cushioning up to a height of 25cm (80+170mm), providing
protective covering with country burnt bricks laid breadth wise,
refilling the trench etc. as required (in ordinary soil).

a Cable size not exceeding 1.50 sq mm 19 core m 294.00


b Cable size not exceeding 2.50 sq mm 14 core m 294.00
c Cable size exceeding 1.50 sq mm 19 core but not exceeding 1.50
sq mm 61 core m 305.00
d Cable size exceeding 2.50 sq mm 14 core but not exceeding 2.50
sq mm 61 core m 305.00
Laying of control cable in additional position with sand
cushioning & protective covering (in ordinary soil)
571 Laying of one number additional PVC insulated and PVC
sheathed armoured control cable of 1.1KV grade of the following
sizes in ground in the same trench in one tier horizontal formation
including widening the trench by 20 cm, sand cushioning up to
height of 25cm, providing protective covering with country burnt
bricks laid breadth wise, refilling the trench etc. as required (in
ordinary soil).

a Cable size not exceeding 1.50 sq mm 19 core m 179.00


b Cable size not exceeding 2.50 sq mm 14 core m 179.00
c Cable size exceeding 1.50 sq mm 19 core but not exceeding 1.50
sq mm 61 core m 185.00
d Cable size exceeding 2.50 sq mm 14 core but not exceeding 2.50
sq mm 61 core m 185.00
Laying of control cable in original position without sand
cushioning & protective covering (in ordinary soil)
572 Laying of one number PVC insulated and PVC sheathed
armoured control cable of 1.1KV grade of the following sizes in
ground including excavation of trench of size 35 x 75 cm,
refilling the trench etc. as required but excluding sand cushioning
and protective covering (in ordinary soil).

a Cable size not exceeding 1.50 sq mm 19 core m 70.00


b Cable size not exceeding 2.50 sq mm 14 core m 70.00
c Cable size exceeding 1.50 sq mm 19 core but not exceeding 1.50
sq mm 61 core m 82.00
d Cable size exceeding 2.50 sq mm 14 core but not exceeding 1.50
sq mm 61 core m 82.00
Laying of control cable in additional position without sand
cushioning & protective covering (in ordinary soil)
573 Laying of one number additional PVC insulated and PVC
sheathed armoured control cable of 1.1KV grade of the following
sizes in ground in the same trench in one tier horizontal formation
including widening the trench by 20 cm, refilling the trench etc.
as required but excluding sand cushioning and protective
covering (in ordinary soil)

a Cable size not exceeding 1.50 sq mm 19 core m 38.00


b Cable size not exceeding 2.50 sq mm 14 core m 38.00
c Cable size exceeding 1.50 sq mm 19 core but not exceeding 1.50
sq mm 61 core m 43.00
d Cable size exceeding 2.50 sq mm 14 core but not exceeding 1.50
sq mm 61 core m 43.00
Laying of control cable in original position with sand
cushioning & protective covering (in hard soil)
574 Laying of one number PVC insulated and PVC sheathed
armoured control cable of 1.1KV grade of the following sizes in
ground including excavation of trench of size 35 x 75 cm, sand
cushioning up to a height of 25cm (80+170mm), providing
protective covering with country burnt bricks laid breadth wise,
refilling the trench etc. as required (in hard soil).

a Cable size not exceeding 1.50 sq mm 19 core m 315.00


b Cable size not exceeding 2.50 sq mm 14 core m 315.00
c Cable size exceeding 1.50 sq mm 19 core but not exceeding 1.50
sq mm 61 core m 326.00
d Cable size exceeding 2.50 sq mm 14 core but not exceeding 1.50
sq mm 61 core m 326.00
Laying of control cable in additional position with sand
cushioning & protective covering (in hard soil)
575 Laying of one number additional PVC insulated and PVC
sheathed armoured control cable of 1.1KV grade of the following
sizes in ground in the same trench in one tier horizontal formation
including widening the trench by 20 cm, sand cushioning up to
height of 25cm, providing protective covering with country burnt
bricks laid breadth wise, refilling the trench etc. as required (in
hard soil).

a Cable size not exceeding 1.50 sq mm 19 core m 191.00


b Cable size not exceeding 2.50 sq mm 14 core m 191.00
c Cable size exceeding 1.50 sq mm 19 core but not exceeding 1.50
sq mm 61 core m 197.00
d Cable size exceeding 2.50 sq mm 14 core but not exceeding 1.50
sq mm 61 core m 197.00
Laying of control cable in original position without sand
cushioning & protective covering (in hard soil)
576 Laying of one number PVC insulated and PVC sheathed
armoured control cable of 1.1KV grade of the following sizes in
ground including excavation of trench of size 35 x 75 cm,
refilling the trench etc. as required but excluding sand cushioning
and protective covering (in hard soil).

a Cable size not exceeding 1.50 sq mm 19 core m 92.00


b Cable size not exceeding 2.50 sq mm 14 core m 92.00
c Cable size exceeding 1.50 sq mm 19 core but not exceeding 1.50
sq mm 61 core m 103.00
d Cable size exceeding 2.50 sq mm 14 core but not exceeding 1.50
sq mm 61 core m 103.00
Laying of control cable in additional position without sand
cushioning & protective covering (in hard soil)
577 Laying of one number additional PVC insulated and PVC
sheathed armoured control cable of 1.1KV grade of the following
sizes in ground in the same trench in one tier horizontal formation
including widening the trench by 20 cm, refilling the trench etc.
as required but excluding sand cushioning and protective
covering (in hard soil)

a Cable size not exceeding 1.50 sq mm 19 core m 50.00


b Cable size not exceeding 2.50 sq mm 14 core m 50.00
c Cable size exceeding 1.50 sq mm 19 core but not exceeding 1.50
sq mm 61 core m 55.00
d Cable size exceeding 2.50 sq mm 14 core but not exceeding 1.50
sq mm 61 core m 55.00
Laying of control cable in original position with sand
cushioning & protective covering (in ordinary rocky soil)

578 Laying of one number PVC insulated and PVC sheathed


armoured control cable of 1.1KV grade of the following sizes in
ground including excavation of trench of size 35 x 75 cm, sand
cushioning up to a height of 25cm (80+170mm), providing
protective covering with country burnt bricks laid breadth wise,
refilling the trench etc. as required (in ordinary rocky - soft
laterite soil).

a Cable size not exceeding 1.50 sq mm 19 core m 355.00


b Cable size not exceeding 2.50 sq mm 14 core m 355.00
c Cable size exceeding 1.50 sq mm 19 core but not exceeding 1.50
sq mm 61 core m 366.00
d Cable size exceeding 2.50 sq mm 14 core but not exceeding 1.50
sq mm 61 core m 366.00
Laying of control cable in additional position with sand
cushioning & protective covering (in ordinary rocky soil)

579 Laying of one number additional PVC insulated and PVC


sheathed armoured control cable of 1.1KV grade of the following
sizes in ground in the same trench in one tier horizontal formation
including widening the trench by 20 cm, sand cushioning up to
height of 25cm, providing protective covering with country burnt
bricks laid breadth wise, refilling the trench etc. as required (in
ordinary rocky - soft laterite soil).

a Cable size not exceeding 1.50 sq mm 19 core m 214.00


b Cable size not exceeding 2.50 sq mm 14 core m 214.00
c Cable size exceeding 1.50 sq mm 19 core but not exceeding 1.50
sq mm 61 core m 219.00
d Cable size exceeding 2.50 sq mm 14 core but not exceeding 1.50
sq mm 61 core m 219.00
Laying of control cable in original position without sand
cushioning & protective covering (in ordinary rocky soil)

580 Laying of one number PVC insulated and PVC sheathed


armoured control cable of 1.1KV grade of the following sizes in
ground including excavation of trench of size 35 x 75 cm,
refilling the trench etc. as required but excluding sand cushioning
and protective covering (in ordinary rocky - soft laterite soil).

a Cable size not exceeding 1.50 sq mm 19 core m 131.00


b Cable size not exceeding 2.50 sq mm 14 core m 131.00
c Cable size exceeding 1.50 sq mm 19 core but not exceeding 1.50
sq mm 61 core m 142.00
d Cable size exceeding 2.50 sq mm 14 core but not exceeding 1.50
sq mm 61 core m 142.00
Laying of control cable in additional position without sand
cushioning & protective covering (in ordinary rocky soil)

581 Laying of one number additional PVC insulated and PVC


sheathed armoured control cable of 1.1KV grade of the following
sizes in ground in the same trench in one tier horizontal formation
including widening the trench by 20 cm, refilling the trench etc.
as required but excluding sand cushioning and protective
covering (in ordinary rocky - soft laterite soil)

a Cable size not exceeding 1.50 sq mm 19 core m 72.00


b Cable size not exceeding 2.50 sq mm 14 core m 72.00
c Cable size exceeding 1.50 sq mm 19 core but not exceeding 1.50
sq mm 61 core m 78.00
d Cable size exceeding 2.50 sq mm 14 core but not exceeding 1.50
sq mm 61 core m 78.00
Laying of control cable through existing pipe
582 Laying of one number PVC insulated and PVC sheathed
armoured control cable of 1.1KV grade of the following sizes in
the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as
required.

a Cable size not exceeding 1.50 sq mm 19 core m 29.00


b Cable size not exceeding 2.50 sq mm 14 core m 29.00
c Cable size exceeding 1.50 sq mm 19 core but not exceeding 1.50
sq mm 61 core m 41.00
d Cable size exceeding 2.50 sq mm 14 core but not exceeding 1.50
sq mm 61 core m 41.00
Laying of control cable in existing masonry open duct
583 Laying of one No. PVC insulated and PVC sheathed armoured
control cable of 1.1 KV grade of the following sizes in the
existing masonry open duct as required.
a Cable size not exceeding 1.50 sq mm 19 core m 24.00
b Cable size not exceeding 2.50 sq mm 14 core m 24.00
c Cable size exceeding 1.50 sq mm 19 core but not exceeding 1.50
sq mm 61 core m 32.00
d Cable size exceeding 2.50 sq mm 14 core but not exceeding 1.50
sq mm 61 core m 32.00
Laying & clamping of control cable
584 Laying and clamping of 1 no. PVC insulated and PVC sheathed
armoured power cable, 1.1 KV grade of the following sizes using
clamps noted along with the cables, spacing of clamps not
exceeding 60cms, making good the damages, colour washing etc.
as required.

a Cable size not exceeding 4 core 1.50/ 2.50 sq mm using factory


made saddles m 27.00
b Cable size exceeding 4 core but not exceeding 7 core 1.50/ 2.50
sq mm using factory made saddles m 32.00
c Cable size exceeding 7 core but not exceeding 10 core 1.50/ 2.50
sq mm using factory made saddles m 56.00
d Cable size exceeding 10 core but not exceeding 14 core 1.50/
2.50 sq mm using factory made saddles m 63.00
e Cable size exceeding 14 core but not exceeding 25 core 1.50/
2.50 sq mm using factory made saddles m 67.00
f Cable size exceeding 25 core but not exceeding 37 core 1.50/
2.50 sq mm using factory made saddles m 78.00
g Cable size exceeding 37 core but not exceeding 44 core 1.50/
2.50 sq mm using factory made saddles m 80.00
h Cable size exceeding 44 core but not exceeding 61 core 1.50/
2.50 sq mm using clamps fabricated from 25 x 3 mm MS flat
m 90.00
Supply & laying of copper control cable 1.1 KV grade in
original position with sand cushioning & protective covering in
ordinary soil
585 Supply & laying of one number PVC insulated and PVC sheathed
armoured control cable of 1.1KV grade of the following sizes in
ground including excavation of trench of size 35 x 75 cm, sand
cushioning up to a height of 25cm (80+170mm), providing
protective covering with country burnt bricks laid breadth wise,
refilling the trench etc. as required (in ordinary soil).

a1 2 core 1.50 sq mm m 386.00


a2 3 core 1.50 sq mm m 404.00
a3 4 core 1.50 sq mm m 428.00
a4 5 core 1.50 sq mm m 455.00
a5 6 core 1.50 sq mm m 477.00
a6 7 core 1.50 sq mm m 492.00
a7 8 core 1.50 sq mm m 533.00
a8 9 core 1.50 sq mm m 561.00
a9 10 core 1.50 sq mm m 583.00
a10 12 core 1.50 sq mm m 596.00
a11 14 core 1.50 sq mm m 640.00
a12 16 core 1.50 sq mm m 683.00
a13 19 core 1.50 sq mm m 756.00
a14 24 core 1.50 sq mm m 867.00
a15 27 core 1.50 sq mm m 926.00
a16 30 core 1.50 sq mm m 1008.00
a17 37 core 1.50 sq mm m 1130.00
a18 44 core 1.50 sq mm m 1283.00
a19 52 core 1.50 sq mm m 1443.00
a20 61 core 1.50 sq mm m 1624.00

b1 2 core 2.50 sq mm m 416.00


b2 3 core 2.50 sq mm m 448.00
b3 4 core 2.50 sq mm m 483.00
b4 5 core 2.50 sq mm m 520.00
b5 6 core 2.50 sq mm m 560.00
b6 7 core 2.50 sq mm m 586.00
b7 8 core 2.50 sq mm m 642.00
b8 9 core 2.50 sq mm m 659.00
b9 10 core 2.50 sq mm m 692.00
b10 12 core 2.50 sq mm m 769.00
b11 14 core 2.50 sq mm m 836.00
b12 16 core 2.50 sq mm m 905.00
b13 19 core 2.50 sq mm m 1004.00
b14 24 core 2.50 sq mm m 1180.00
b15 30 core 2.50 sq mm m 1379.00
b16 37 core 2.50 sq mm m 1612.00
b17 44 core 2.50 sq mm m 1849.00
b18 52 core 2.50 sq mm m 2107.00
b19 61 core 2.50 sq mm m 2400.00
Supply & laying of copper control cable 1.1 KV grade in
additional position with sand cushioning & protective covering
in ordinary soil
586 Supply & laying of one number additional PVC insulated and
PVC sheathed armoured control cable of 1.1KV grade of the
following sizes in ground in the same trench in one tier horizontal
formation including widening the trench by 20 cm, sand
cushioning up to height of 25cm, providing protective covering
with country burnt bricks laid breadth wise, refilling the trench
etc. as required (in ordinary soil).

a1 2 core 1.50 sq mm m 272.00


a2 3 core 1.50 sq mm m 290.00
a3 4 core 1.50 sq mm m 314.00
a4 5 core 1.50 sq mm m 341.00
a5 6 core 1.50 sq mm m 363.00
a6 7 core 1.50 sq mm m 379.00
a7 8 core 1.50 sq mm m 419.00
a8 9 core 1.50 sq mm m 447.00
a9 10 core 1.50 sq mm m 469.00
a10 12 core 1.50 sq mm m 482.00
a11 14 core 1.50 sq mm m 526.00
a12 16 core 1.50 sq mm m 569.00
a13 19 core 1.50 sq mm m 636.00
a14 24 core 1.50 sq mm m 747.00
a15 27 core 1.50 sq mm m 807.00
a16 30 core 1.50 sq mm m 888.00
a17 37 core 1.50 sq mm m 1010.00
a18 44 core 1.50 sq mm m 1163.00
a19 52 core 1.50 sq mm m 1324.00
a20 61 core 1.50 sq mm m 1504.00

b1 2 core 2.50 sq mm m 302.00


b2 3 core 2.50 sq mm m 334.00
b3 4 core 2.50 sq mm m 369.00
b4 5 core 2.50 sq mm m 406.00
b5 6 core 2.50 sq mm m 446.00
b6 7 core 2.50 sq mm m 472.00
b7 8 core 2.50 sq mm m 528.00
b8 9 core 2.50 sq mm m 545.00
b9 10 core 2.50 sq mm m 578.00
b10 12 core 2.50 sq mm m 650.00
b11 14 core 2.50 sq mm m 717.00
b12 16 core 2.50 sq mm m 786.00
b13 19 core 2.50 sq mm m 884.00
b14 24 core 2.50 sq mm m 1060.00
b15 30 core 2.50 sq mm m 1260.00
b16 37 core 2.50 sq mm m 1492.00
b17 44 core 2.50 sq mm m 1729.00
b18 52 core 2.50 sq mm m 1987.00
b19 61 core 2.50 sq mm m 2280.00
Supply & laying of copper control cable 1.1 KV grade in
original position without sand cushioning & protective covering
in ordinary soil
587 Supply & laying of one number PVC insulated and PVC sheathed
armoured control cable of 1.1KV grade of the following sizes in
ground including excavation of trench of size 35 x 75 cm,
refilling the trench etc. as required but excluding sand cushioning
& protective covering (in ordinary soil).

a1 2 core 1.50 sq mm m 160.00


a2 3 core 1.50 sq mm m 182.00
a3 4 core 1.50 sq mm m 206.00
a4 5 core 1.50 sq mm m 233.00
a5 6 core 1.50 sq mm m 256.00
a6 7 core 1.50 sq mm m 271.00
a7 8 core 1.50 sq mm m 311.00
a8 9 core 1.50 sq mm m 339.00
a9 10 core 1.50 sq mm m 361.00
a10 12 core 1.50 sq mm m 374.00
a11 14 core 1.50 sq mm m 418.00
a12 16 core 1.50 sq mm m 461.00
a13 19 core 1.50 sq mm m 523.00
a14 24 core 1.50 sq mm m 645.00
a15 27 core 1.50 sq mm m 705.00
a16 30 core 1.50 sq mm m 786.00
a17 37 core 1.50 sq mm m 908.00
a18 44 core 1.50 sq mm m 1061.00
a19 52 core 1.50 sq mm m 1221.00
a20 61 core 1.50 sq mm m 1402.00

b1 2 core 2.50 sq mm m 195.00


b2 3 core 2.50 sq mm m 226.00
b3 4 core 2.50 sq mm m 261.00
b4 5 core 2.50 sq mm m 298.00
b5 6 core 2.50 sq mm m 338.00
b6 7 core 2.50 sq mm m 365.00
b7 8 core 2.50 sq mm m 420.00
b8 9 core 2.50 sq mm m 438.00
b9 10 core 2.50 sq mm m 470.00
b10 12 core 2.50 sq mm m 548.00
b11 14 core 2.50 sq mm m 614.00
b12 16 core 2.50 sq mm m 684.00
b13 19 core 2.50 sq mm m 782.00
b14 24 core 2.50 sq mm m 958.00
b15 30 core 2.50 sq mm m 1157.00
b16 37 core 2.50 sq mm m 1390.00
b17 44 core 2.50 sq mm m 1627.00
b18 52 core 2.50 sq mm m 1885.00
b19 61 core 2.50 sq mm m 2178.00
Supply & laying of copper control cable 1.1 KV grade in
additional position without sand cushioning & protective
covering in ordinary soil
588 Supply & laying of one number additional PVC insulated and
PVC sheathed armoured control cable of 1.1KV grade of the
following sizes in ground in the same trench in one tier horizontal
formation including widening the trench by 20 cm, refilling the
trench etc. as required but excluding sand cushioning and
protective covering (in ordinary soil)

a1 2 core 1.50 sq mm m 127.00


a2 3 core 1.50 sq mm m 150.00
a3 4 core 1.50 sq mm m 173.00
a4 5 core 1.50 sq mm m 201.00
a5 6 core 1.50 sq mm m 223.00
a6 7 core 1.50 sq mm m 238.00
a7 8 core 1.50 sq mm m 278.00
a8 9 core 1.50 sq mm m 306.00
a9 10 core 1.50 sq mm m 329.00
a10 12 core 1.50 sq mm m 341.00
a11 14 core 1.50 sq mm m 385.00
a12 16 core 1.50 sq mm m 429.00
a13 19 core 1.50 sq mm m 490.00
a14 24 core 1.50 sq mm m 607.00
a15 27 core 1.50 sq mm m 666.00
a16 30 core 1.50 sq mm m 748.00
a17 37 core 1.50 sq mm m 870.00
a18 44 core 1.50 sq mm m 1023.00
a19 52 core 1.50 sq mm m 1183.00
a20 61 core 1.50 sq mm m 1364.00

b1 2 core 2.50 sq mm m 162.00


b2 3 core 2.50 sq mm m 194.00
b3 4 core 2.50 sq mm m 228.00
b4 5 core 2.50 sq mm m 265.00
b5 6 core 2.50 sq mm m 305.00
b6 7 core 2.50 sq mm m 332.00
b7 8 core 2.50 sq mm m 387.00
b8 9 core 2.50 sq mm m 405.00
b9 10 core 2.50 sq mm m 438.00
b10 12 core 2.50 sq mm m 509.00
b11 14 core 2.50 sq mm m 576.00
b12 16 core 2.50 sq mm m 645.00
b13 19 core 2.50 sq mm m 744.00
b14 24 core 2.50 sq mm m 920.00
b15 30 core 2.50 sq mm m 1119.00
b16 37 core 2.50 sq mm m 1352.00
b17 44 core 2.50 sq mm m 1588.00
b18 52 core 2.50 sq mm m 1847.00
b19 61 core 2.50 sq mm m 2140.00
Supply & laying of copper control cable 1.1 KV grade in
original position with sand cushioning & protective covering in
hard soil
589 Supply & laying of one number PVC insulated and PVC sheathed
armoured control cable of 1.1KV grade of the following sizes in
ground including excavation of trench of size 35 x 75 cm, sand
cushioning up to a height of 25cm (80+170mm), providing
protective covering with country burnt bricks laid breadth wise,
refilling the trench etc. as required (in hard soil).

a1 2 core 1.50 sq mm m 407.00


a2 3 core 1.50 sq mm m 429.00
a3 4 core 1.50 sq mm m 449.00
a4 5 core 1.50 sq mm m 476.00
a5 6 core 1.50 sq mm m 498.00
a6 7 core 1.50 sq mm m 514.00
a7 8 core 1.50 sq mm m 554.00
a8 9 core 1.50 sq mm m 582.00
a9 10 core 1.50 sq mm m 604.00
a10 12 core 1.50 sq mm m 617.00
a11 14 core 1.50 sq mm m 661.00
a12 16 core 1.50 sq mm m 704.00
a13 19 core 1.50 sq mm m 777.00
a14 24 core 1.50 sq mm m 888.00
a15 27 core 1.50 sq mm m 947.00
a16 30 core 1.50 sq mm m 1029.00
a17 37 core 1.50 sq mm m 1151.00
a18 44 core 1.50 sq mm m 1304.00
a19 52 core 1.50 sq mm m 1464.00
a20 61 core 1.50 sq mm m 1645.00

b1 2 core 2.50 sq mm m 437.00


b2 3 core 2.50 sq mm m 469.00
b3 4 core 2.50 sq mm m 504.00
b4 5 core 2.50 sq mm m 541.00
b5 6 core 2.50 sq mm m 581.00
b6 7 core 2.50 sq mm m 607.00
b7 8 core 2.50 sq mm m 663.00
b8 9 core 2.50 sq mm m 680.00
b9 10 core 2.50 sq mm m 713.00
b10 12 core 2.50 sq mm m 790.00
b11 14 core 2.50 sq mm m 857.00
b12 16 core 2.50 sq mm m 926.00
b13 19 core 2.50 sq mm m 1025.00
b14 24 core 2.50 sq mm m 1201.00
b15 30 core 2.50 sq mm m 1400.00
b16 37 core 2.50 sq mm m 1633.00
b17 44 core 2.50 sq mm m 1870.00
b18 52 core 2.50 sq mm m 2128.00
b19 61 core 2.50 sq mm m 2421.00
Supply & laying of copper control cable 1.1 KV grade in
additional position with sand cushioning & protective covering
in hard soil
590 Supply & laying of one number additional PVC insulated and
PVC sheathed armoured control cable of 1.1KV grade of the
following sizes in ground in the same trench in one tier horizontal
formation including widening the trench by 20 cm, sand
cushioning up to height of 25cm, providing protective covering
with country burnt bricks laid breadth wise, refilling the trench
etc. as required (in hard soil).

a1 2 core 1.50 sq mm m 284.00


a2 3 core 1.50 sq mm m 302.00
a3 4 core 1.50 sq mm m 326.00
a4 5 core 1.50 sq mm m 353.00
a5 6 core 1.50 sq mm m 375.00
a6 7 core 1.50 sq mm m 391.00
a7 8 core 1.50 sq mm m 431.00
a8 9 core 1.50 sq mm m 459.00
a9 10 core 1.50 sq mm m 481.00
a10 12 core 1.50 sq mm m 494.00
a11 14 core 1.50 sq mm m 538.00
a12 16 core 1.50 sq mm m 581.00
a13 19 core 1.50 sq mm m 648.00
a14 24 core 1.50 sq mm m 759.00
a15 27 core 1.50 sq mm m 819.00
a16 30 core 1.50 sq mm m 900.00
a17 37 core 1.50 sq mm m 1022.00
a18 44 core 1.50 sq mm m 1175.00
a19 52 core 1.50 sq mm m 1336.00
a20 61 core 1.50 sq mm m 1516.00

b1 2 core 2.50 sq mm m 314.00


b2 3 core 2.50 sq mm m 346.00
b3 4 core 2.50 sq mm m 381.00
b4 5 core 2.50 sq mm m 418.00
b5 6 core 2.50 sq mm m 458.00
b6 7 core 2.50 sq mm m 484.00
b7 8 core 2.50 sq mm m 540.00
b8 9 core 2.50 sq mm m 557.00
b9 10 core 2.50 sq mm m 590.00
b10 12 core 2.50 sq mm m 662.00
b11 14 core 2.50 sq mm m 729.00
b12 16 core 2.50 sq mm m 798.00
b13 19 core 2.50 sq mm m 896.00
b14 24 core 2.50 sq mm m 1072.00
b15 30 core 2.50 sq mm m 1272.00
b16 37 core 2.50 sq mm m 1505.00
b17 44 core 2.50 sq mm m 1741.00
b18 52 core 2.50 sq mm m 1999.00
b19 61 core 2.50 sq mm m 2292.00
Supply & laying of copper control cable 1.1 KV grade in
original position without sand cushioning & protective covering
in hard soil
591 Supply & laying of one number PVC insulated and PVC sheathed
armoured control cable of 1.1KV grade of the following sizes in
ground including excavation of trench of size 35 x 75 cm,
refilling the trench etc. as required but excluding sand cushioning
& protective covering (in hard soil).

a1 2 core 1.50 sq mm m 181.00


a2 3 core 1.50 sq mm m 203.00
a3 4 core 1.50 sq mm m 227.00
a4 5 core 1.50 sq mm m 254.00
a5 6 core 1.50 sq mm m 277.00
a6 7 core 1.50 sq mm m 292.00
a7 8 core 1.50 sq mm m 332.00
a8 9 core 1.50 sq mm m 360.00
a9 10 core 1.50 sq mm m 382.00
a10 12 core 1.50 sq mm m 395.00
a11 14 core 1.50 sq mm m 439.00
a12 16 core 1.50 sq mm m 482.00
a13 19 core 1.50 sq mm m 544.00
a14 24 core 1.50 sq mm m 666.00
a15 27 core 1.50 sq mm m 726.00
a16 30 core 1.50 sq mm m 807.00
a17 37 core 1.50 sq mm m 929.00
a18 44 core 1.50 sq mm m 1082.00
a19 52 core 1.50 sq mm m 1242.00
a20 61 core 1.50 sq mm m 1423.00

b1 2 core 2.50 sq mm m 216.00


b2 3 core 2.50 sq mm m 247.00
b3 4 core 2.50 sq mm m 282.00
b4 5 core 2.50 sq mm m 319.00
b5 6 core 2.50 sq mm m 359.00
b6 7 core 2.50 sq mm m 386.00
b7 8 core 2.50 sq mm m 441.00
b8 9 core 2.50 sq mm m 459.00
b9 10 core 2.50 sq mm m 492.00
b10 12 core 2.50 sq mm m 569.00
b11 14 core 2.50 sq mm m 635.00
b12 16 core 2.50 sq mm m 705.00
b13 19 core 2.50 sq mm m 803.00
b14 24 core 2.50 sq mm m 979.00
b15 30 core 2.50 sq mm m 1178.00
b16 37 core 2.50 sq mm m 1411.00
b17 44 core 2.50 sq mm m 1648.00
b18 52 core 2.50 sq mm m 1906.00
b19 61 core 2.50 sq mm m 2199.00
Supply & laying of copper control cable 1.1 KV grade in
additional position without sand cushioning & protective
covering in hard soil
592 Supply & laying of one number additional PVC insulated and
PVC sheathed armoured control cable of 1.1KV grade of the
following sizes in ground in the same trench in one tier horizontal
formation including widening the trench by 20 cm, refilling the
trench etc. as required but excluding sand cushioning and
protective covering (in hard soil)
a1 2 core 1.50 sq mm m 139.00
a2 3 core 1.50 sq mm m 162.00
a3 4 core 1.50 sq mm m 185.00
a4 5 core 1.50 sq mm m 213.00
a5 6 core 1.50 sq mm m 235.00
a6 7 core 1.50 sq mm m 250.00
a7 8 core 1.50 sq mm m 290.00
a8 9 core 1.50 sq mm m 318.00
a9 10 core 1.50 sq mm m 341.00
a10 12 core 1.50 sq mm m 353.00
a11 14 core 1.50 sq mm m 397.00
a12 16 core 1.50 sq mm m 441.00
a13 19 core 1.50 sq mm m 502.00
a14 24 core 1.50 sq mm m 619.00
a15 27 core 1.50 sq mm m 678.00
a16 30 core 1.50 sq mm m 760.00
a17 37 core 1.50 sq mm m 882.00
a18 44 core 1.50 sq mm m 1035.00
a19 52 core 1.50 sq mm m 1195.00
a20 61 core 1.50 sq mm m 1376.00

b1 2 core 2.50 sq mm m 174.00


b2 3 core 2.50 sq mm m 206.00
b3 4 core 2.50 sq mm m 241.00
b4 5 core 2.50 sq mm m 277.00
b5 6 core 2.50 sq mm m 317.00
b6 7 core 2.50 sq mm m 344.00
b7 8 core 2.50 sq mm m 399.00
b8 9 core 2.50 sq mm m 417.00
b9 10 core 2.50 sq mm m 450.00
b10 12 core 2.50 sq mm m 521.00
b11 14 core 2.50 sq mm m 588.00
b12 16 core 2.50 sq mm m 657.00
b13 19 core 2.50 sq mm m 756.00
b14 24 core 2.50 sq mm m 931.00
b15 30 core 2.50 sq mm m 1131.00
b16 37 core 2.50 sq mm m 1364.00
b17 44 core 2.50 sq mm m 1600.00
b18 52 core 2.50 sq mm m 1859.00
b19 61 core 2.50 sq mm m 2152.00
Supply & laying of copper control cable 1.1 KV grade in
original position with sand cushioning & protective covering in
ordinary rocky soil
593 Supply & laying of one number PVC insulated and PVC sheathed
armoured control cable of 1.1KV grade of the following sizes in
ground including excavation of trench of size 35 x 75 cm, sand
cushioning up to a height of 25cm (80+170mm), providing
protective covering with country burnt bricks laid breadth wise,
refilling the trench etc. as required (in ordinary rocky - soft
laterite soil).

a1 2 core 1.50 sq mm m 447.00


a2 3 core 1.50 sq mm m 465.00
a3 4 core 1.50 sq mm m 488.00
a4 5 core 1.50 sq mm m 516.00
a5 6 core 1.50 sq mm m 538.00
a6 7 core 1.50 sq mm m 553.00
a7 8 core 1.50 sq mm m 592.00
a8 9 core 1.50 sq mm m 621.00
a9 10 core 1.50 sq mm m 644.00
a10 12 core 1.50 sq mm m 656.00
a11 14 core 1.50 sq mm m 700.00
a12 16 core 1.50 sq mm m 744.00
a13 19 core 1.50 sq mm m 817.00
a14 24 core 1.50 sq mm m 928.00
a15 27 core 1.50 sq mm m 987.00
a16 30 core 1.50 sq mm m 1069.00
a17 37 core 1.50 sq mm m 1191.00
a18 44 core 1.50 sq mm m 1344.00
a19 52 core 1.50 sq mm m 1504.00
a20 61 core 1.50 sq mm m 1685.00

b1 2 core 2.50 sq mm m 477.00


b2 3 core 2.50 sq mm m 509.00
b3 4 core 2.50 sq mm m 544.00
b4 5 core 2.50 sq mm m 581.00
b5 6 core 2.50 sq mm m 620.00
b6 7 core 2.50 sq mm m 647.00
b7 8 core 2.50 sq mm m 702.00
b8 9 core 2.50 sq mm m 720.00
b9 10 core 2.50 sq mm m 753.00
b10 12 core 2.50 sq mm m 830.00
b11 14 core 2.50 sq mm m 897.00
b12 16 core 2.50 sq mm m 966.00
b13 19 core 2.50 sq mm m 1065.00
b14 24 core 2.50 sq mm m 1240.00
b15 30 core 2.50 sq mm m 1440.00
b16 37 core 2.50 sq mm m 1673.00
6 44 core 2.50 sq mm m 1909.00
b18 52 core 2.50 sq mm m 2168.00
b19 61 core 2.50 sq mm m 2461.00
Supply & laying of copper control cable 1.1 KV grade in
additional position with sand cushioning & protective covering
in ordinary rocky soil
594 Supply & laying of one number additional PVC insulated and
PVC sheathed armoured control cable of 1.1KV grade of the
following sizes in ground in the same trench in one tier horizontal
formation including widening the trench by 20 cm, sand
cushioning up to height of 25cm, providing protective covering
with country burnt bricks laid breadth wise, refilling the trench
etc. as required (in ordinary rocky - soft laterite soil).

a1 2 core 1.50 sq mm m 307.00


a2 3 core 1.50 sq mm m 325.00
a3 4 core 1.50 sq mm m 349.00
a4 5 core 1.50 sq mm m 376.00
a5 6 core 1.50 sq mm m 398.00
a6 7 core 1.50 sq mm m 413.00
a7 8 core 1.50 sq mm m 453.00
a8 9 core 1.50 sq mm m 481.00
a9 10 core 1.50 sq mm m 504.00
a10 12 core 1.50 sq mm m 516.00
a11 14 core 1.50 sq mm m 560.00
a12 16 core 1.50 sq mm m 604.00
a13 19 core 1.50 sq mm m 671.00
a14 24 core 1.50 sq mm m 782.00
a15 27 core 1.50 sq mm m 842.00
a16 30 core 1.50 sq mm m 923.00
a17 37 core 1.50 sq mm m 1045.00
a18 44 core 1.50 sq mm m 1198.00
a19 52 core 1.50 sq mm m 1358.00
a20 61 core 1.50 sq mm m 1539.00

b1 2 core 2.50 sq mm m 337.00


b2 3 core 2.50 sq mm m 369.00
b3 4 core 2.50 sq mm m 404.00
b4 5 core 2.50 sq mm m 441.00
b5 6 core 2.50 sq mm m 480.00
b6 7 core 2.50 sq mm m 507.00
b7 8 core 2.50 sq mm m 563.00
b8 9 core 2.50 sq mm m 580.00
b9 10 core 2.50 sq mm m 613.00
b10 12 core 2.50 sq mm m 684.00
b11 14 core 2.50 sq mm m 751.00
b12 16 core 2.50 sq mm m 820.00
b13 19 core 2.50 sq mm m 919.00
b14 24 core 2.50 sq mm m 1095.00
b15 30 core 2.50 sq mm m 1294.00
b16 37 core 2.50 sq mm m 1527.00
b17 44 core 2.50 sq mm m 1764.00
b18 52 core 2.50 sq mm m 2022.00
b19 61 core 2.50 sq mm m 2315.00
Supply & laying of copper control cable 1.1 KV grade in
original position without sand cushioning & protective covering
in ordinary rocky soil
595 Supply & laying of one number PVC insulated and PVC sheathed
armoured control cable of 1.1KV grade of the following sizes in
ground including excavation of trench of size 35 x 75 cm,
refilling the trench etc. as required but excluding sand cushioning
& protective covering (in ordinary rocky - soft laterite soil).

a1 2 core 1.50 sq mm m 221.00


a2 3 core 1.50 sq mm m 243.00
a3 4 core 1.50 sq mm m 267.00
a4 5 core 1.50 sq mm m 294.00
a5 6 core 1.50 sq mm m 316.00
a6 7 core 1.50 sq mm m 332.00
a7 8 core 1.50 sq mm m 372.00
a8 9 core 1.50 sq mm m 400.00
a9 10 core 1.50 sq mm m 422.00
a10 12 core 1.50 sq mm m 435.00
a11 14 core 1.50 sq mm m 479.00
a12 16 core 1.50 sq mm m 522.00
a13 19 core 1.50 sq mm m 584.00
a14 24 core 1.50 sq mm m 706.00
a15 27 core 1.50 sq mm m 766.00
a16 30 core 1.50 sq mm m 847.00
a17 37 core 1.50 sq mm m 969.00
a18 44 core 1.50 sq mm m 1122.00
a19 52 core 1.50 sq mm m 1282.00
a20 61 core 1.50 sq mm m 1463.00

b1 2 core 2.50 sq mm m 255.00


b2 3 core 2.50 sq mm m 287.00
b3 4 core 2.50 sq mm m 322.00
b4 5 core 2.50 sq mm m 359.00
b5 6 core 2.50 sq mm m 399.00
b6 7 core 2.50 sq mm m 425.00
b7 8 core 2.50 sq mm m 481.00
b8 9 core 2.50 sq mm m 498.00
b9 10 core 2.50 sq mm m 531.00
b10 12 core 2.50 sq mm m 608.00
b11 14 core 2.50 sq mm m 675.00
b12 16 core 2.50 sq mm m 744.00
b13 19 core 2.50 sq mm m 843.00
b14 24 core 2.50 sq mm m 1019.00
b15 30 core 2.50 sq mm m 1218.00
b16 37 core 2.50 sq mm m 1451.00
b17 44 core 2.50 sq mm m 1688.00
b18 52 core 2.50 sq mm m 1946.00
b19 61 core 2.50 sq mm m 2239.00
Supply & laying of copper control cable 1.1 KV grade in
additional position without sand cushioning & protective
covering in ordinary rocky soil
596 Supply & laying of one number additional PVC insulated and
PVC sheathed armoured control cable of 1.1KV grade of the
following sizes in ground in the same trench in one tier horizontal
formation including widening the trench by 20 cm, refilling the
trench etc. as required but excluding sand cushioning and
protective covering (in ordinary rocky - soft laterite soil)

a1 2 core 1.50 sq mm m 162.00


a2 3 core 1.50 sq mm m 184.00
a3 4 core 1.50 sq mm m 208.00
a4 5 core 1.50 sq mm m 235.00
a5 6 core 1.50 sq mm m 257.00
a6 7 core 1.50 sq mm m 273.00
a7 8 core 1.50 sq mm m 313.00
a8 9 core 1.50 sq mm m 341.00
a9 10 core 1.50 sq mm m 363.00
a10 12 core 1.50 sq mm m 376.00
a11 14 core 1.50 sq mm m 420.00
a12 16 core 1.50 sq mm m 463.00
a13 19 core 1.50 sq mm m 525.00
a14 24 core 1.50 sq mm m 641.00
a15 27 core 1.50 sq mm m 701.00
a16 30 core 1.50 sq mm m 782.00
a17 37 core 1.50 sq mm m 905.00
a18 44 core 1.50 sq mm m 1058.00
a19 52 core 1.50 sq mm m 1218.00
a20 61 core 1.50 sq mm m 1399.00

b1 2 core 2.50 sq mm m 197.00


b2 3 core 2.50 sq mm m 228.00
b3 4 core 2.50 sq mm m 263.00
b4 5 core 2.50 sq mm m 300.00
b5 6 core 2.50 sq mm m 340.00
b6 7 core 2.50 sq mm m 366.00
b7 8 core 2.50 sq mm m 422.00
b8 9 core 2.50 sq mm m 439.00
b9 10 core 2.50 sq mm m 472.00
b10 12 core 2.50 sq mm m 544.00
b11 14 core 2.50 sq mm m 611.00
b12 16 core 2.50 sq mm m 680.00
b13 19 core 2.50 sq mm m 778.00
b14 24 core 2.50 sq mm m 954.00
b15 30 core 2.50 sq mm m 1154.00
b16 37 core 2.50 sq mm m 1387.00
b17 44 core 2.50 sq mm m 1623.00
b18 52 core 2.50 sq mm m 1882.00
b19 61 core 2.50 sq mm m 2174.00
Supply & laying of copper control cable 1.1 KV grade through
the existing pipe
597 Supply & laying of one number PVC insulated and PVC sheathed
armoured control cable of 1.1KV grade of the following sizes in
the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as
required.

a1 2 core 1.50 sq mm m 119.00


a2 3 core 1.50 sq mm m 141.00
a3 4 core 1.50 sq mm m 165.00
a4 5 core 1.50 sq mm m 192.00
a5 6 core 1.50 sq mm m 214.00
a6 7 core 1.50 sq mm m 230.00
a7 8 core 1.50 sq mm m 270.00
a8 9 core 1.50 sq mm m 298.00
a9 10 core 1.50 sq mm m 320.00
a10 12 core 1.50 sq mm m 333.00
a11 14 core 1.50 sq mm m 377.00
a12 16 core 1.50 sq mm m 420.00
a13 19 core 1.50 sq mm m 482.00
a14 24 core 1.50 sq mm m 593.00
a15 27 core 1.50 sq mm m 664.00
a16 30 core 1.50 sq mm m 745.00
a17 37 core 1.50 sq mm m 867.00
a18 44 core 1.50 sq mm m 1020.00
a19 52 core 1.50 sq mm m 1180.00
a20 61 core 1.50 sq mm m 1361.00

b1 2 core 2.50 sq mm m 154.00


b2 3 core 2.50 sq mm m 185.00
b3 4 core 2.50 sq mm m 220.00
b4 5 core 2.50 sq mm m 257.00
b5 6 core 2.50 sq mm m 297.00
b6 7 core 2.50 sq mm m 324.00
b7 8 core 2.50 sq mm m 379.00
b8 9 core 2.50 sq mm m 397.00
b9 10 core 2.50 sq mm m 429.00
b10 12 core 2.50 sq mm m 507.00
b11 14 core 2.50 sq mm m 573.00
b12 16 core 2.50 sq mm m 642.00
b13 19 core 2.50 sq mm m 741.00
b14 24 core 2.50 sq mm m 917.00
b15 30 core 2.50 sq mm m 1116.00
b16 37 core 2.50 sq mm m 1349.00
b17 44 core 2.50 sq mm m 1586.00
b18 52 core 2.50 sq mm m 1844.00
b19 61 core 2.50 sq mm m 2137.00
Supply & laying of copper control cable 1.1 KV grade in the
existing masonry open duct
598 Supply, laying of one No. PVC insulated and PVC sheathed
armoured control cable of 1.1 KV grade of the following sizes in
the existing masonry open duct as required.
a1 2 core 1.50 sq mm m 114.00
a2 3 core 1.50 sq mm m 136.00
a3 4 core 1.50 sq mm m 159.00
a4 5 core 1.50 sq mm m 187.00
a5 6 core 1.50 sq mm m 209.00
a6 7 core 1.50 sq mm m 224.00
a7 8 core 1.50 sq mm m 264.00
a8 9 core 1.50 sq mm m 292.00
a9 10 core 1.50 sq mm m 315.00
a10 12 core 1.50 sq mm m 327.00
a11 14 core 1.50 sq mm m 371.00
a12 16 core 1.50 sq mm m 415.00
a13 19 core 1.50 sq mm m 477.00
a14 24 core 1.50 sq mm m 587.00
a15 27 core 1.50 sq mm m 655.00
a16 30 core 1.50 sq mm m 737.00
a17 37 core 1.50 sq mm m 859.00
a18 44 core 1.50 sq mm m 1012.00
a19 52 core 1.50 sq mm m 1172.00
a20 61 core 1.50 sq mm m 1353.00

b1 2 core 2.50 sq mm m 148.00


b2 3 core 2.50 sq mm m 180.00
b3 4 core 2.50 sq mm m 215.00
b4 5 core 2.50 sq mm m 251.00
b5 6 core 2.50 sq mm m 291.00
b6 7 core 2.50 sq mm m 318.00
b7 8 core 2.50 sq mm m 373.00
b8 9 core 2.50 sq mm m 391.00
b9 10 core 2.50 sq mm m 424.00
b10 12 core 2.50 sq mm m 498.00
b11 14 core 2.50 sq mm m 565.00
b12 16 core 2.50 sq mm m 634.00
b13 19 core 2.50 sq mm m 733.00
b14 24 core 2.50 sq mm m 908.00
b15 30 core 2.50 sq mm m 1108.00
b16 37 core 2.50 sq mm m 1341.00
b17 44 core 2.50 sq mm m 1577.00
b18 52 core 2.50 sq mm m 1836.00
b19 61 core 2.50 sq mm m 2129.00
Supply, laying & clamping of copper control cable 1.1 KV grade
599 Supply, laying and clamping of 1 no. PVC insulated and PVC
sheathed armoured power cable, 1.1 KV grade of the following
sizes using clamps noted along with the cables, spacing of clamps
not exceeding 60cms, making good the damages, colour washing
etc. as required.
a1 2 core 1.50 sq mm using factory made saddles m 121.00
a2 3 core 1.50 sq mm using factory made saddles m 139.00
a3 4 core 1.50 sq mm using factory made saddles m 162.00
a4 5 core 1.50 sq mm using factory made saddles m 195.00
a5 6 core 1.50 sq mm using factory made saddles m 217.00
a6 7 core 1.50 sq mm using factory made saddles m 233.00
a7 8 core 1.50 sq mm using factory made saddles m 296.00
a8 9 core 1.50 sq mm using factory made saddles m 324.00
a9 10 core 1.50 sq mm using factory made saddles m 347.00
a10 12 core 1.50 sq mm using factory made saddles m 366.00
a11 14 core 1.50 sq mm using factory made saddles m 410.00
a12 16 core 1.50 sq mm using factory made saddles m 457.00
a13 19 core 1.50 sq mm using factory made saddles m 519.00
a14 24 core 1.50 sq mm using factory made saddles m 630.00
a15 27 core 1.50 sq mm using factory made saddles m 701.00
a16 30 core 1.50 sq mm using factory made saddles m 782.00
a17 37 core 1.50 sq mm using factory made saddles m 905.00
a18 44 core 1.50 sq mm using clamps fabricated from 20 x 3 mm MS
flat m 1059.00
a19 52 core 1.50 sq mm using clamps fabricated from 20 x 3 mm MS
flat m 1229.00
a20 61 core 1.50 sq mm using clamps fabricated from 20 x 3 mm MS
flat m 1410.00

b1 2 core 2.50 sq mm using factory made saddles m 151.00


b2 3 core 2.50 sq mm using factory made saddles m 183.00
b3 4 core 2.50 sq mm using factory made saddles m 218.00
b4 5 core 2.50 sq mm using factory made saddles m 261.00
b5 6 core 2.50 sq mm using factory made saddles m 300.00
b6 7 core 2.50 sq mm using factory made saddles m 327.00
b7 8 core 2.50 sq mm using factory made saddles m 406.00
b8 9 core 2.50 sq mm using factory made saddles m 423.00
b9 10 core 2.50 sq mm using factory made saddles m 456.00
b10 12 core 2.50 sq mm using factory made saddles m 529.00
b11 14 core 2.50 sq mm using factory made saddles m 596.00
b12 16 core 2.50 sq mm using factory made saddles m 669.00
b13 19 core 2.50 sq mm using factory made saddles m 768.00
b14 24 core 2.50 sq mm using factory made saddles m 944.00
b15 30 core 2.50 sq mm using factory made saddles m 1155.00
b16 37 core 2.50 sq mm using factory made saddles m 1388.00
b17 44 core 2.50 sq mm using clamps fabricated from 20 x 3 mm MS
flat m 1626.00
b18 52 core 2.50 sq mm using clamps fabricated from 20 x 3 mm MS
flat m 1893.00
b19 61 core 2.50 sq mm using clamps fabricated from 20 x 3 mm MS
flat m 2186.00

11 KV XLPE CABLES
Laying of 11 KV grade XLPE cable in original position with
sand cushioning & protective covering (in ordinary soil)

620 Laying of 1 no. 11 KV grade XLPE cable of the following sizes


in ground including excavation of trench of size 35 x 120cm,
sand cushioning up to a height of 25cm, providing protective
covering with country burnt bricks laid breadth wise, refilling the
trench etc. as required (in ordinary soil).

a Cable size not exceeding 3 core 120 sq mm m 338.00


b Cable size exceeding 3 core 120 sq mm but not exceeding 3 core
400 sq mm m 349.00
Laying of 11 KV grade XLPE cable in additional position with
sand cushioning & protective covering (in ordinary soil)

621 Laying of 1 no. additional 11 KV grade XLPE cable of the


following sizes in ground including excavation of trench of size
35 x 120 cm, sand cushioning up to a height of 25 cm, providing
protective covering with country burnt bricks laid breadth wise,
refilling the trench etc. as required (in ordinary soil).

a Cable size not exceeding 3 core 120 sq mm m 287.00


b Cable size exceeding 3 core 120 sq mm but not exceeding 3 core
400 sq mm m 293.00
Laying of 11 KV grade XLPE cable in original position with
sand cushioning & protective covering (in hard soil)

622 Laying of 1 no. 11 KV grade XLPE cable of the following sizes


in ground including excavation of trench of size 35 x 120cm,
sand cushioning up to a height of 25cm, providing protective
covering with country burnt bricks laid breadth wise, refilling the
trench etc. as required (in hard soil).

a Cable size not exceeding 3 core 120 sq mm m 371.00


b Cable size exceeding 3 core 120 sq mm but not exceeding 3 core
400 sq mm m 383.00
Laying of 11 KV grade XLPE cable in additional position with
sand cushioning & protective covering (in hard soil)

623 Laying of 1 no. additional 11 KV grade XLPE cable of the


following sizes in ground including excavation of trench of size
35 x 120 cm, sand cushioning up to a height of 25 cm, providing
protective covering with country burnt bricks laid breadth wise,
refilling the trench etc. as required (in hard soil).

a Cable size not exceeding 3 core 120 sq mm m 307.00


b Cable size exceeding 3 core 120 sq mm but not exceeding 3 core
400 sq mm m 312.00
Laying of 11 KV grade XLPE cable in original position with
sand cushioning & protective covering (in ordinary rocky soil)

624 Laying of 1 no. 11 KV grade XLPE cable of the following sizes


in ground including excavation of trench of size 35 x 120cm,
sand cushioning up to a height of 25cm, providing protective
covering with country burnt bricks laid breadth wise, refilling the
trench etc. as required (in ordinary rocky - soft laterite soil).

a Cable size not exceeding 3 core 120 sq mm m 435.00


b Cable size exceeding 3 core 120 sq mm but not exceeding 3 core
400 sq mm m 446.00
Laying of 11 KV grade XLPE cable in additional position with
sand cushioning & protective covering (in ordinary rocky soil)

625 Laying of 1 no. additional 11 KV grade XLPE cable of the


following sizes in ground including excavation of trench of size
35 x 120 cm, sand cushioning up to a height of 25 cm, providing
protective covering with country burnt bricks laid breadth wise,
refilling the trench etc. as required (in ordinary rocky - soft
laterite soil).

a Cable size not exceeding 3 core 120 sq mm m 343.00


b Cable size exceeding 3 core 120 sq mm but not exceeding 3 core
400 sq mm m 348.00
Laying of 11 KV grade XLPE cable through existing pipe

626 Laying of one number 11 KV grade XLPE cable of the following


sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC
pipe as required.
a Cable size not exceeding 3 core 400 sq mm m 59.00
Laying of 11 KV grade XLPE cable in existing masonry open
627 duct
Laying of one No. 11 KV grade XLPE cable of the following
sizes in the existing masonry open duct as required.

a Cable size not exceeding 3 core 400 sq mm m 47.00


Laying & clamping of 11 KV grade XLPE cable
628 Laying and clamping of 1 no. 11 KV grade XLPE cable of the
following sizes using clamps fabricated from 20 x 3 mm MS flat,
spacing of clamps not exceeding 60cms, making good the
damages, colour washing etc. as required.

a Cable size not exceeding 3 core 400 sq mm m 110.00


Supply & laying of 11 KV grade XLPE cable in original
position with sand cushioning & protective covering (in
ordinary soil)
629 Supply & laying of 1 no. 11 KV grade XLPE cable of the
following sizes in ground including excavation of trench of size
35 x 120cm, sand cushioning up to a height of 25cm, providing
protective covering with country burnt bricks laid breadth wise,
refilling the trench etc. as required (in ordinary soil).

a 3 core 120 sq mm m 1635.00


b 3 core 150 sq mm m 1814.00
c 3 core 185 sq mm m 2055.00
d 3 core 240 sq mm m 2447.00
e 3 core 300 sq mm m 2767.00
f 3 core 400 sq mm m 3271.00
Supply & laying of 11 KV grade XLPE cable in additional
position with sand cushioning & protective covering (in
ordinary soil)
630 Supply & laying of 1 no. additional 11 KV grade XLPE cable of
the following sizes in ground including excavation of trench of
size 35 x 120 cm, sand cushioning up to a height of 25 cm,
providing protective covering with country burnt bricks laid
breadth wise, refilling the trench etc. as required (in ordinary
soil).

a 3 core 120 sq mm m 1584.00


b 3 core 150 sq mm m 1758.00
c 3 core 185 sq mm m 1999.00
d 3 core 240 sq mm m 2391.00
e 3 core 300 sq mm m 2711.00
f 3 core 400 sq mm m 3215.00
Supply & laying of 11 KV grade XLPE cable in original
position with sand cushioning & protective covering (in hard
soil)
631 Supply & laying of 1 no. 11 KV grade XLPE cable of the
following sizes in ground including excavation of trench of size
35 x 120cm, sand cushioning up to a height of 25cm, providing
protective covering with country burnt bricks laid breadth wise,
refilling the trench etc. as required (in hard soil).

a 3 core 120 sq mm m 1668.00


b 3 core 150 sq mm m 1847.00
c 3 core 185 sq mm m 2089.00
d 3 core 240 sq mm m 2480.00
e 3 core 300 sq mm m 2800.00
f 3 core 400 sq mm m 3305.00
Supply & laying of 11 KV grade XLPE cable in additional
position with sand cushioning & protective covering (in hard
soil)
632 Supply & laying of 1 no. additional 11 KV grade XLPE cable of
the following sizes in ground including excavation of trench of
size 35 x 120 cm, sand cushioning up to a height of 25 cm,
providing protective covering with country burnt bricks laid
breadth wise, refilling the trench etc. as required (in hard soil).

a 3 core 120 sq mm m 1604.00


b 3 core 150 sq mm m 1777.00
c 3 core 185 sq mm m 2019.00
d 3 core 240 sq mm m 2410.00
e 3 core 300 sq mm m 2730.00
f 3 core 400 sq mm m 3235.00
Supply & laying of 11 KV grade XLPE cable in original
position with sand cushioning & protective covering (in
ordinary rocky soil)
633 Supply & laying of 1 no. 11 KV grade XLPE cable of the
following sizes in ground including excavation of trench of size
35 x 120cm, sand cushioning up to a height of 25cm, providing
protective covering with country burnt bricks laid breadth wise,
refilling the trench etc. as required (in ordinary rocky - soft
laterite soil).

a 3 core 120 sq mm m 1732.00


b 3 core 150 sq mm m 1911.00
c 3 core 185 sq mm m 2152.00
d 3 core 240 sq mm m 2544.00
e 3 core 300 sq mm m 2864.00
f 3 core 400 sq mm m 3368.00
Supply & laying of 11 KV grade XLPE cable in additional
position with sand cushioning & protective covering (in
ordinary rocky soil)
634 Supply & laying of 1 no. additional 11 KV grade XLPE cable of
the following sizes in ground including excavation of trench of
size 35 x 120 cm, sand cushioning up to a height of 25 cm,
providing protective covering with country burnt bricks laid
breadth wise, refilling the trench etc. as required (in ordinary
rocky - soft laterite soil).

a 3 core 120 sq mm m 1640.00


b 3 core 150 sq mm m 1813.00
c 3 core 185 sq mm m 2055.00
d 3 core 240 sq mm m 2447.00
e 3 core 300 sq mm m 2766.00
f 3 core 400 sq mm m 3271.00
Supply & laying of 11 KV grade XLPE cable through existing
conduit.
635 Supply & laying of one number 11 KV grade XLPE cable of the
following sizes in the existing RCC/ HUME / STONE WARE/
GI/ DWC pipe as required.
a 3 core 120 sq mm m 1357.00
b 3 core 150 sq mm m 1525.00
c 3 core 185 sq mm m 1767.00
d 3 core 240 sq mm m 2158.00
e 3 core 300 sq mm m 2478.00
f 3 core 400 sq mm m 2983.00
Supply & laying of 11 KV grade XLPE cable in existing
masonry open duct
636 Supply & laying of one No. 11 KV grade XLPE cable of the
following sizes in the existing masonry open duct as required.

a 3 core 120 sq mm m 1346.00


b 3 core 150 sq mm m 1514.00
c 3 core 185 sq mm m 1756.00
d 3 core 240 sq mm m 2147.00
e 3 core 300 sq mm m 2467.00
f 3 core 400 sq mm m 2972.00
Supply, laying & clamping of 11 KV grade XLPE cable
637 Supply, laying and clamping of 1 no. 11 KV grade XLPE cable of
the following sizes using clamps fabricated from 20 x 3 mm MS
flat, spacing of clamps not exceeding 60cms, making good the
damages, colour washing etc. as required.
a 3 core 120 sq mm m 1395.00
b 3 core 150 sq mm m 1568.00
c 3 core 185 sq mm m 1801.00
d 3 core 240 sq mm m 2189.00
e 3 core 300 sq mm m 2506.00
f 3 core 400 sq mm m 3006.00

PROTECTIVE PIPES TO CABLES


650 Supplying, laying and jointing of the following sizes of double
wall corrugated (DWC) pipes made out of HDPE conforming to
IS 14930 Part II for mechanical protection to underground power
cables with all required accessories in ground in the existing
trench

a 50 / 38 mm or nearest size m 109.00


b 63 / 50 mm or nearest size m 128.00
c 77 / 63 mm or nearest size m 145.00
d 90 / 75 mm or nearest size m 184.00
e 110 / 94 mm or nearest size m 262.00
f 120 / 102.50 mm or nearest size m 273.00
g 125 / 109 mm or nearest size m 320.00
h 145 / 123 mm or nearest size m 396.00
i 160 / 135 mm or nearest size m 428.00
j 175 / 147 mm or nearest size m 487.00
k 200 / 174 mm or nearest size m 570.00
651 Supplying, laying and jointing of the following sizes of double
wall corrugated (DWC) pipes made out of HDPE conforming to
IS 14930 Part II for mechanical protection to underground power
cables with all required accessories in ground including
excavation of trench to a depth of 75 cm and refilling the trench
with the excavated soil etc as required (in ordinary soil)

a 50 / 38 mm or nearest size m 115.00


b 63 / 50 mm or nearest size m 132.00
c 77 / 63 mm or nearest size m 147.00
d 90 / 75 mm or nearest size m 181.00
e 110 / 94 mm or nearest size m 249.00
f 120 / 102.50 mm or nearest size m 258.00
652 Supplying, laying and jointing of the following sizes of double
wall corrugated (DWC) pipes made out of HDPE conforming to
IS 14930 Part II for mechanical protection to underground power
cables with all required accessories in ground including
excavation of trench to a depth of 75 cm and refilling the trench
with the excavated soil etc as required (in hard soil)

a 50 / 38 mm or nearest size m 133.00


b 63 / 50 mm or nearest size m 150.00
c 77 / 63 mm or nearest size m 165.00
d 90 / 75 mm or nearest size m 199.00
e 110 / 94 mm or nearest size m 267.00
f 120 / 102.50 mm or nearest size m 276.00
653 Supplying, laying and jointing of the following sizes of double
wall corrugated (DWC) pipes made out of HDPE conforming to
IS 14930 Part II for mechanical protection to underground power
cables with all required accessories in ground including
excavation of trench to a depth of 75 cm and refilling the trench
with the excavated soil etc as required (in ordinary rocky - soft
laterite soil)
a 50 / 38 mm or nearest size m 167.00
b 63 / 50 mm or nearest size m 184.00
c 77 / 63 mm or nearest size m 199.00
d 90 / 75 mm or nearest size m 233.00
e 110 / 94 mm or nearest size m 301.00
f 120 / 102.50 mm or nearest size m 310.00
654 Supplying, laying and jointing of the following sizes of double
wall corrugated (DWC) pipes made out of HDPE conforming to
IS 14930 Part II for mechanical protection to underground power
cables with all required accessories in ground including
excavation of trench to a depth of 120 cm and refilling the trench
with the excavated soil etc as required (in ordinary soil)

a 120 / 102.50 mm or nearest size m 270.00


b 125 / 109 mm or nearest size m 312.00
c 145 / 123 mm or nearest size m 378.00
d 160 / 135 mm or nearest size m 405.00
e 175 / 147 mm or nearest size m 457.00
f 200 / 174 mm or nearest size m 529.00
655 Supplying, laying and jointing of the following sizes of double
wall corrugated (DWC) pipes made out of HDPE conforming to
IS 14930 Part II for mechanical protection to underground power
cables with all required accessories in ground including
excavation of trench to a depth of 120 cm and refilling the trench
with the excavated soil etc as required (in hard soil)

a 120 / 102.50 mm or nearest size m 299.00


b 125 / 109 mm or nearest size m 641.00
c 145 / 123 mm or nearest size m 407.00
d 160 / 135 mm or nearest size m 434.00
e 175 / 147 mm or nearest size m 485.00
f 200 / 174 mm or nearest size m 558.00
656 Supplying, laying and jointing of the following sizes of double
wall corrugated (DWC) pipes made out of HDPE conforming to
IS 14930 Part II for mechanical protection to underground power
cables with all required accessories in ground including
excavation of trench to a depth of 120 cm and refilling the trench
with the excavated soil etc as required (in ordinary rocky - soft
laterite soil)

a 50 / 38 mm or nearest size m 310.00


b 63 / 50 mm or nearest size m 351.00
c 77 / 63 mm or nearest size m 418.00
d 90 / 75 mm or nearest size m 445.00
e 110 / 94 mm or nearest size m 496.00
f 120 / 102.50 mm or nearest size m 569.00
657 Supplying & laying the following sizes of double wall corrugated
(DWC) half round pipes made out of HDPE conforming to IS
14930 Part II for mechanical protection to underground power
cables with all required accessories in ground in the existing
trench etc as required.
a 50 / 38 mm or nearest size m 62.00
b 63 / 50 mm or nearest size m 73.00
c 77 / 63 mm or nearest size m 82.00
d 90 / 75 mm or nearest size m 105.00
e 110 / 94 mm or nearest size m 151.00
f 120 / 102.50 mm or nearest size m 156.00
g 125 / 109 mm or nearest size m 184.00
h 145 / 123 mm or nearest size m 229.00
i 160 / 135 mm or nearest size m 248.00
j 175 / 147 mm or nearest size m 281.00
k 200 / 174 mm or nearest size m 330.00
658 Supply and clamping the following sizes of PVC pipe on wall
with all required accessories including cutting and making good
the walls, colour washing etc. as required as protective covering
to cables.

a 32 mm dia PVC pipe (8 Kgf / cm2) m 51.00


b 40 mm dia PVC pipe (8 Kgf / cm2) m 53.00
c 50 mm dia PVC pipe (8 Kgf / cm )2
m 70.00
d 63 mm dia PVC pipe (8 Kgf / cm2) m 101.00
e 75 mm dia PVC pipe (8 Kgf / cm )2
m 139.00
f 90 mm dia PVC pipe (8 Kgf / cm2) m 188.00
g 110 mm dia PVC pipe (8 Kgf / cm ) 2
m 280.00
ROUTE - MARKER
670 Supplying and fixing route marker with cement concrete 1:2:4 of
size 60x60 cm at the bottom and 50x50 cm at the top with a
thickness of 10cm including inscription as required. E 194.00
671 Supply route marker with 10cmx10cm GI plate 5mm thick with
inscriptions there on bolted / welded to 35x35x6mm angle iron
60cm long and fixing the same in ground as required.
E 151.00
END TERMINATION OF CABLES
680 Supplying siemens / tropodur type nickel plated single
compression brass cable gland for PVC insulated and PVC
sheathed armoured aluminium/ copper conductor cable 1.1 KV
grade, and making end termination suitable for 2/ 3/ 3½/ 4 core
cable of the following sizes as required.

a 2.5 sq mm E 76.00
b 4 sq mm E 83.00
c 6 sq mm E 90.00
d 10 sq mm E 100.00
e 16 sq mm E 128.00
f 25 sq mm E 137.00
g 35 sq mm E 169.00
h 50 sq mm E 194.00
i 70 sq mm E 234.00
j 95 sq mm E 250.00
k 120 sq mm E 292.00
l 150 sq mm E 316.00
m 185 sq mm E 376.00
n 240 sq mm E 518.00
p 300 sq mm E 531.00
q 3 x 400 sq mm E 603.00
r 3.5/ 4 x 400 sq mm E 640.00
EARTH CLAMPS
685 Supplying and providing earth clamps for siemens/ tropodur type
cable glands of suitable length and other dimensions noted along
with each size of glands for the following sizes of cables as
required.

a 1.5 sq mm with 12 mm wide x 1 mm thick clip E 14.00


b 2.5 sq mm with 12 mm wide x 1 mm thick clip E 14.00
c 4 sq mm with 12 mm wide x 1 mm thick clip E 14.00
d 6 sq mm with 12 mm wide x 1 mm thick clip E 14.00
e 10 sq mm with 12 mm wide x 1 mm thick clip E 14.00
f 16 sq mm with 12 mm wide x 1 mm thick clip E 14.00
g 25 sq mm with 20 mm wide x 1.20 mm thick clip E 23.00
h 35 sq mm with 20 mm wide x 1.20 mm thick clip E 23.00
i 50 sq mm with 20 mm wide x 1.20 mm thick clip E 23.00
j 70 sq mm with 20 mm wide x 1.20 mm thick clip E 23.00
k 95 sq mm with 20 mm wide x 1.20 mm thick clip E 23.00
686 Supplying and providing earth clamps made out of copper strips
of the following sizes including cutting and bending the flat
exactly to the shape of the gland, drilling necessary holes for nut
& bolt, tinning the points of contacts and giving connections to
the main earthing system as required.

a 20 x 3 mm for earthing glands of size 120 sq mm to 185 sq mm


E 79.00
b 25 x 3 mm for earthing glands of size 240 sq mm to 300 sq mm
E 116.00
c 25 x 6 mm for earthing glands of size 400 sq mm to 630 sq mm
E 311.00
CABLE SOCKETS
690 Supply of superior quality aluminium tubular cable socket and
making core termination of cables of the following sizes
including crimping etc. as required.
a 2.5 sq mm E 8.60
b 4 sq mm E 8.60
c 6 sq mm E 8.80
d 10 sq mm E 8.90
e 16 sq mm E 9.70
f 25 sq mm E 10.50
g 35 sq mm E 11.80
h 50 sq mm E 14.00
i 70 sq mm E 19.00
j 95 sq mm E 21.00
k 120 sq mm E 33.00
l 150 sq mm E 38.00
m 185 sq mm E 46.00
n 240 sq mm E 65.00
p 300 sq mm E 86.00
q 400 sq mm E 112.00
691 Supply of superior quality aluminium reducer (banana) cable
socket and making core termination of cables of the following
sizes including crimping etc. as required.
a 2.5 sq mm E 10.50
b 4 sq mm E 10.50
c 6 sq mm E 10.50
d 10 sq mm E 11.80
e 16 sq mm E 14.50
f 25 sq mm E 17.50
g 35 sq mm E 20.00
h 50 sq mm E 25.00
i 70 sq mm E 31.00
j 95 sq mm E 47.00
k 120 sq mm E 76.00
l 150 sq mm E 87.00
m 185 sq mm E 114.00
n 240 sq mm E 202.00
p 300 sq mm E 254.00
692 Supply of superior quality aluminium in-line ferrules and making
core termination of cables of the following sizes including
crimping etc. as required.
a 2.5 sq mm E 8.20
b 4 sq mm E 8.20
c 6 sq mm E 8.20
d 10 sq mm E 8.20
e 16 sq mm E 9.30
f 25 sq mm E 10.20
g 35 sq mm E 11.30
h 50 sq mm E 14.00
i 70 sq mm E 19.00
j 95 sq mm E 19.00
k 120 sq mm E 31.00
l 150 sq mm E 34.00
m 185 sq mm E 41.50
n 240 sq mm E 59.00
p 300 sq mm E 80.00
q 400 sq mm E 105.50
693 Supply of superior quality copper tubular cable socket and
making core termination of cables of the following sizes
including crimping etc. as required.
a 2.5 sq mm E 9.70
b 4 sq mm E 14.00
c 6 sq mm E 14.00
d 10 sq mm E 15.50
e 16 sq mm E 19.00
f 25 sq mm E 26.50
g 35 sq mm E 31.00
h 50 sq mm E 41.50
i 70 sq mm E 62.00
j 95 sq mm E 75.00
k 120 sq mm E 87.50
l 150 sq mm E 113.00
m 185 sq mm E 163.00
n 240 sq mm E 238.00
p 300 sq mm E 294.00
q 400 sq mm E 426.00
694 Supply of superior quality copper reducer (banana) cable socket
and making core termination of cables of the following sizes
including crimping etc. as required.
a 2.5 sq mm E 17.30
b 4 sq mm E 17.30
c 6 sq mm E 17.30
d 10 sq mm E 21.00
e 16 sq mm E 27.50
f 25 sq mm E 39.50
g 35 sq mm E 51.50
h 50 sq mm E 56.50
i 70 sq mm E 81.50
j 95 sq mm E 118.00
k 120 sq mm E 225.00
l 150 sq mm E 254.00
m 185 sq mm E 273.00
n 240 sq mm E 571.00
695 Supply of superior quality copper in-line ferrule cable socket and
making core termination of cables of the following sizes
including crimping etc. as required.
a 1.5 sq mm E 9.50
b 2.5 sq mm E 10.50
c 4 sq mm E 12.00
d 6 sq mm E 13.00
e 10 sq mm E 14.00
f 16 sq mm E 17.00
g 25 sq mm E 25.00
h 35 sq mm E 29.00
i 50 sq mm E 36.00
j 70 sq mm E 56.00
k 95 sq mm E 69.00
l 120 sq mm E 81.00
m 150 sq mm E 100.00
n 185 sq mm E 150.00
p 240 sq mm E 220.00
q 300 sq mm E 282.00
r 400 sq mm E 389.00
697 Supply of superior quality copper bare ring terminal and making
core termination of cables of the following sizes including
crimping etc. as required.
a 1.5 sq mm E 8.00
b 2.5 sq mm E 8.80
c 4 sq mm E 11.10
d 6 sq mm E 11.10
e 10 sq mm E 11.70
f 16 sq mm E 17.00
g 25 sq mm E 22.00
h 35 sq mm E 28.00
i 50 sq mm E 44.00
j 70 sq mm E 62.00
k 95 sq mm E 72.50
698 Supply of superior quality copper insulated ring terminal and
making core termination of cables of the following sizes
including crimping etc. as required.
a 1.5 sq mm E 8.20
b 2.5 sq mm E 9.00
c 4 sq mm E 11.40
d 6 sq mm E 11.40
e 10 sq mm E 12.10
f 16 sq mm E 17.00
699 Supply of superior quality copper bare fork terminal and making
core termination of cables of the following sizes including
crimping etc. as required.
a 1.5 sq mm E 8.30
b 2.5 sq mm E 8.70
c 4 sq mm E 11.10
d 6 sq mm E 11.10
e 10 sq mm E 13.00
f 16 sq mm E 17.50
700 Supply of superior quality copper insulated fork terminal and
making core termination of cables of the following sizes
including crimping etc. as required.
a 1.5 sq mm E 8.60
b 2.5 sq mm E 8.90
c 4 sq mm E 11.40
d 6 sq mm E 11.40
e 10 sq mm E 13.00
f 16 sq mm E 18.00
701 Supply of superior quality copper soldering terminal and making
core termination of cables of the following ratings including
soldering etc. as required.
a 15 A E 11.20
b 30 A E 14.00
c 60 A E 24.00
d 100 A E 43.00
e 150 A E 65.00
f 200 A E 91.00
g 300 A E 183.00
h 400 A E 218.00
i 500 A E 279.00
JOINTS AND TERMINATIONS FOR CABLES
710 Supply and making straight through joint for 1.1 KV grade
PVC/PILC/XLPE cables of the following sizes including supply
of cable jointing kit consisting of cable jointing compound,
hardener, plastic mould, adhesive-cum-solvent, fast curing epoxy,
sponge sheet, mould holding clips, earth continuity connection,
epoxy cast spacer, PVC (NA) tapes etc. as required.

a1 2 core 4 sq mm E 891.00
a2 2 core 6 sq mm E 891.00
a3 2 core 10 sq mm E 891.00
a4 2 core 16 sq mm E 1217.00
a5 2 core 25 sq mm E 1217.00
a6 2 core 35 sq mm E 1217.00
a7 2 core 50 sq mm E 1406.00
a8 2 core 70 sq mm E 1406.00
a9 2 core 95 sq mm E 1629.00
a10 2 core 120 sq mm E 1745.00
a11 2 core 150 sq mm E 1745.00
b1 3 core 4 sq mm E 891.00
b2 3 core 6 sq mm E 891.00
b3 3 core 10 sq mm E 891.00
b4 3 core 16 sq mm E 1217.00
b5 3 core 25 sq mm E 1217.00
b6 3 core 35 sq mm E 1364.00
b7 3 core 50 sq mm E 1406.00
b8 3 core 70 sq mm E 1629.00
b9 3 core 95 sq mm E 1861.00
b10 3 core 120 sq mm E 1926.00
b11 3 core 150 sq mm E 1926.00
b12 3 core 185 sq mm E 2667.00
b13 3 core 240 sq mm E 3015.00
b13 3 core 300 sq mm E 3569.00
b14 3 core 400 sq mm E 4119.00

c1 3.5 core 25 sq mm E 1365.00


c2 3.5 core 35 sq mm E 1406.00
c3 3.5 core 50 sq mm E 1738.00
c4 3.5 core 70 sq mm E 1861.00
c5 3.5 core 95 sq mm E 1926.00
c6 3.5 core 120 sq mm E 2667.00
c7 3.5 core 150 sq mm E 2697.00
c8 3.5 core 185 sq mm E 2811.00
c9 3.5 core 240 sq mm E 3569.00
c10 3.5 core 300 sq mm E 4119.00
c11 3.5 core 400 sq mm E 4920.00

d1 4 core 4 sq mm E 891.00
d2 4 core 6 sq mm E 891.00
d3 4 core 10 sq mm E 1217.00
d4 4 core 16 sq mm E 1217.00
d5 4 core 25 sq mm E 1406.00
d6 4 core 35 sq mm E 1406.00
d7 4 core 50 sq mm E 1738.00
d8 4 core 70 sq mm E 1861.00
d9 4 core 95 sq mm E 1926.00
d10 4 core 120 sq mm E 2667.00
d11 4 core 150 sq mm E 2697.00
d12 4 core 185 sq mm E 2811.00
d13 4 core 240 sq mm E 3569.00
d13 4 core 300 sq mm E 4119.00
d14 4 core 400 sq mm E 4920.00
711 Supply and making outdoor / indoor end termination for 1.1 KV
grade PVC/PILC/XLPE cables of the following sizes including
supply of end sealing kit consisting of cable jointing compound,
hardener, plastic mould, adhesive-cum-solvent, epoxy putty, earth
continuity connection, spacers and PVC (NA) tape.

a1 2 core 10 sq mm E 651.00
a2 2 core 16 sq mm E 651.00
a3 2 core 25 sq mm E 673.00
a4 2 core 35 sq mm E 673.00
a5 2 core 50 sq mm E 673.00
a6 2 core 70 sq mm E 813.00
a7 2 core 95 sq mm E 813.00
a8 2 core 120 sq mm E 995.00
a9 2 core 150 sq mm E 995.00
a10 2 core 185 sq mm E 1074.00
a11 2 core 240 sq mm E 1408.00
a12 2 core 300 sq mm E 1408.00
a13 2 core 400 sq mm E 1620.00

b1 3 core 10 sq mm E 651.00
b2 3 core 16 sq mm E 673.00
b3 3 core 25 sq mm E 673.00
b4 3 core 35 sq mm E 673.00
b5 3 core 50 sq mm E 813.00
b6 3 core 70 sq mm E 813.00
b7 3 core 95 sq mm E 1074.00
b8 3 core 120 sq mm E 1074.00
b9 3 core 150 sq mm E 1074.00
b10 3 core 185 sq mm E 1408.00
b11 3 core 240 sq mm E 1620.00
b12 3 core 300 sq mm E 1620.00
b13 3 core 400 sq mm E 2048.00

c1 3.5 core 25 sq mm E 673.00


c2 3.5 core 35 sq mm E 813.00
c3 3.5 core 50 sq mm E 903.00
c4 3.5 core 70 sq mm E 995.00
c5 3.5 core 95 sq mm E 1074.00
c6 3.5 core 120 sq mm E 1074.00
c7 3.5 core 150 sq mm E 1408.00
c8 3.5 core 185 sq mm E 1408.00
c9 3.5 core 240 sq mm E 1620.00
c10 3.5 core 300 sq mm E 1728.00
c11 3.5 core 400 sq mm E 2048.00

d1 4 core 10 sq mm E 673.00
d2 4 core 16 sq mm E 673.00
d3 4 core 25 sq mm E 673.00
d4 4 core 35 sq mm E 903.00
d5 4 core 50 sq mm E 903.00
d6 4 core 70 sq mm E 995.00
d7 4 core 95 sq mm E 1074.00
d8 4 core 120 sq mm E 1074.00
d9 4 core 150 sq mm E 1408.00
d10 4 core 185 sq mm E 1408.00
d11 4 core 240 sq mm E 1620.00
d12 4 core 300 sq mm E 1728.00
d13 4 core 400 sq mm E 2048.00
712 Supplying and making indoor end termination with push-on end
termination kit (earthed) for 11 KV grade XLPE cable of the
following sizes including supply of end sealing kit consisting of
stress-cum-semi conducting pad, sliding core, self bonding
insulating tape, boot (with 3 core kit), earth continuity connection
(with 3 core kit), earthing lug (with 1 core kit), adhesive-cum-
solvent, PVC (NA) tape, silicon grease, aluminium crimping lug,
aluminium oxide cloth, nylon string, copper binding wire, hose
clamp and bi-metallic washer etc. as required.

a 3 x 150 sq mm E 8482.00
b 3 x 185 sq mm E 9257.00
c 3 x 240 sq mm E 9257.00
d 3 x 300 sq mm E 10390.00
e 3 x 400 sq mm E 10390.00
713 Supplying and making outdoor end termination with push-on end
termination kit (earthed) for 11 KV grade XLPE cable of the
following sizes including supply of end sealing kit consisting of
stress-cum-semi conducting pad, cap, rain shield, self bonding
insulating case, leakage current collector, protective corrugated
hose pipe, boot, earth continuity connection (with 3 core kit
only), earthing lug (with 1 core kit), adhesive-cum-solvent, PVC
(NA) tape, silicon grease, aluminium crimping lug, aluminium
oxide cloth, nylon string, copper binding wire, hose clamp and bi-
metallic washer etc. as required.

a 3 x 150 sq mm E 9891.00
b 3 x 185 sq mm E 10640.00
c 3 x 240 sq mm E 10640.00
d 3 x 300 sq mm E 11618.00
e 3 x 400 sq mm E 11618.00
PART XV
EARTHING & EARTH CONDUCTORS
720 Supply and providing plate earthing as per IS 3043 with
1200x1200x12 mm GI/CI earth plate, 50 mm GI watering pipe
fixed to the earth plate with 25 x 3mm GI clamps, GI funnel with
weld mesh, filling required quantity of charcoal including
construction of inspection chamber with a bed concrete of 1:4:8
PCC using 40 mm broken stone (10 cm thick), brick work in
cement mortar 1:6, plastering the surface of brick masonry and
the exposed surface of PCC bed with cement mortar 1:4, 12 mm
thick, (the finished inside dimension shall be 450 x 450 x 450
mm) but excluding test joint, earth continuity conductor to the
plate, and covering at the top. (in ordinary soil)
E 9317.00
721 Supply and providing plate earthing as per IS 3043 with
1200x1200x12 mm GI/CI earth plate, 50 mm GI watering pipe
fixed to the earth plate with 25 x 3mm GI clamps, GI funnel with
weld mesh, filling required quantity of charcoal including
construction of inspection chamber with a bed concrete of 1:4:8
PCC using 40 mm broken stone (10 cm thick), brick work in
cement mortar 1:6, plastering the surface of brick masonry and
the exposed surface of PCC bed with cement mortar 1:4, 12 mm
thick, (the finished inside dimension shall be 450 x 450 x 450
mm) but excluding test joint, earth continuity conductor to the
plate, and covering at the top. (in hard soil)
E 9360.00
722 Supply and providing plate earthing as per IS 3043 with
1200x1200x12 mm GI/CI earth plate, 50 mm GI watering pipe
fixed to the earth plate with 25 x 3mm GI clamps, GI funnel with
weld mesh, filling required quantity of charcoal including
construction of inspection chamber with a bed concrete of 1:4:8
PCC using 40 mm broken stone (10 cm thick), brick work in
cement mortar 1:6, plastering the surface of brick masonry and
the exposed surface of PCC bed with cement mortar 1:4, 12 mm
thick, (the finished inside dimension shall be 450 x 450 x 450
mm) but excluding test joint, earth continuity conductor to the
plate, and covering at the top. (in ordinary rocky - soft laterite
soil)

E 7910.00
723 Supply and providing plate earthing as per IS 3043 with
600x600x6.30 mm GI/CI earth plate, 20 mm GI watering pipe
fixed to the earth plate with 20 x 3 mm GI clamps, GI funnel
with weld mesh, filling required quantity of charcoal including
construction of inspection chamber with a bed concrete of 1:4:8
PCC using 40 mm broken stone (10 cm thick), brick work in
cement mortar 1:6, plastering the surface of brick masonry and
the exposed surface of PCC bed with cement mortar 1:4, 12 mm
thick, (the finished inside dimension shall be 300 x 300 x 300
mm) but excluding test joint, earth continuity conductor to the
plate, and covering at the top. (in ordinary soil)

E 3118.00
724 Supply and providing plate earthing as per IS 3043 with
600x600x6.30 mm GI/CI earth plate, 20 mm GI watering pipe
fixed to the earth plate with 20 x 3 mm GI clamps, GI funnel
with weld mesh, filling required quantity of charcoal including
construction of inspection chamber with a bed concrete of 1:4:8
PCC using 40 mm broken stone (10 cm thick), brick work in
cement mortar 1:6, plastering the surface of brick masonry and
the exposed surface of PCC bed with cement mortar 1:4, 12 mm
thick, (the finished inside dimension shall be 300 x 300 x 300
mm) but excluding test joint, earth continuity conductor to the
plate, and covering at the top. (in hard soil)

E 3212.00
725 Supply and providing plate earthing as per IS 3043 with
600x600x6.30 mm GI/CI earth plate, 20 mm GI watering pipe
fixed to the earth plate with 20 x 3 mm GI clamps, GI funnel
with weld mesh, filling required quantity of charcoal including
construction of inspection chamber with a bed concrete of 1:4:8
PCC using 40 mm broken stone (10 cm thick), brick work in
cement mortar 1:6, plastering the surface of brick masonry and
the exposed surface of PCC bed with cement mortar 1:4, 12 mm
thick, (the finished inside dimension shall be 300 x 300 x 300
mm) but excluding test joint, earth continuity conductor to the
plate, and covering at the top. (in ordinary rock - soft laterite
soil)

E 3354.00
726 Supply and providing plate earthing as per IS 3043 with
600x600x6.00 mm copper earth plate, 20 mm GI watering pipe
fixed to the earth plate with 20 x 3 mm GI clamps, GI funnel
with weld mesh, filling required quantity of charcoal including
construction of inspection chamber with a bed concrete of 1:4:8
PCC using 40 mm broken stone (10 cm thick), brick work in
cement mortar 1:6, plastering the surface of brick masonry and
the exposed surface of PCC bed with cement mortar 1:4, 12 mm
thick, (the finished inside dimension shall be 300 x 300 x 300
mm) but excluding test joint, earth continuity conductor to the
plate, and covering at the top. (in ordinary soil)
E 14289.00
727 Supply and providing plate earthing as per IS 3043 with
600x600x6.00 mm copper earth plate, 20 mm GI watering pipe
fixed to the earth plate with 20 x 3 mm GI clamps, GI funnel
with weld mesh, filling required quantity of charcoal including
construction of inspection chamber with a bed concrete of 1:4:8
PCC using 40 mm broken stone (10 cm thick), brick work in
cement mortar 1:6, plastering the surface of brick masonry and
the exposed surface of PCC bed with cement mortar 1:4, 12 mm
thick, (the finished inside dimension shall be 300 x 300 x 300
mm) but excluding test joint, earth continuity conductor to the
plate, and covering at the top. (in hard soil)

E 14383.00
728 Supply and providing plate earthing as per IS 3043 with
600x600x6.00 mm copper earth plate, 20 mm GI watering pipe
fixed to the earth plate with 20 x 3 mm GI clamps, GI funnel
with weld mesh, filling required quantity of charcoal including
construction of inspection chamber with a bed concrete of 1:4:8
PCC using 40 mm broken stone (10 cm thick), brick work in
cement mortar 1:6, plastering the surface of brick masonry and
the exposed surface of PCC bed with cement mortar 1:4, 12 mm
thick, (the finished inside dimension shall be 300 x 300 x 300
mm) but excluding test joint, earth continuity conductor to the
plate, and covering at the top. (in ordinary rock - soft laterite
soil) E 14525.00
729 Supply and providing plate earthing as per IS 3043 with
600x600x3.00 mm copper earth plate, 20 mm GI watering pipe
fixed to the earth plate with 20 x 3 mm GI clamps, GI funnel
with weld mesh, filling required quantity of charcoal including
construction of inspection chamber with a bed concrete of 1:4:8
PCC using 40 mm broken stone (10 cm thick), brick work in
cement mortar 1:6, plastering the surface of brick masonry and
the exposed surface of PCC bed with cement mortar 1:4, 12 mm
thick, (the finished inside dimension shall be 300 x 300 x 300
mm) but excluding test joint, earth continuity conductor to the
plate, and covering at the top. (in ordinary soil)
E 8553.00
730 Supply and providing plate earthing as per IS 3043 with
600x600x3.00 mm copper earth plate, 20 mm GI watering pipe
fixed to the earth plate with 20 x 3 mm GI clamps, GI funnel
with weld mesh, filling required quantity of charcoal including
construction of inspection chamber with a bed concrete of 1:4:8
PCC using 40 mm broken stone (10 cm thick), brick work in
cement mortar 1:6, plastering the surface of brick masonry and
the exposed surface of PCC bed with cement mortar 1:4, 12 mm
thick, (the finished inside dimension shall be 300 x 300 x 300
mm) but excluding test joint, earth continuity conductor to the
plate, and covering at the top. (in hard soil)
E 8647.00
731 Supply and providing plate earthing as per IS 3043 with
600x600x3.00 mm copper earth plate, 20 mm GI watering pipe
fixed to the earth plate with 20 x 3 mm GI clamps, GI funnel
with weld mesh, filling required quantity of charcoal including
construction of inspection chamber with a bed concrete of 1:4:8
PCC using 40 mm broken stone (10 cm thick), brick work in
cement mortar 1:6, plastering the surface of brick masonry and
the exposed surface of PCC bed with cement mortar 1:4, 12 mm
thick, (the finished inside dimension shall be 300 x 300 x 300
mm) but excluding test joint, earth continuity conductor to the
plate, and covering at the top. (in ordinary rock - soft laterite
soil) E 8788.00
732 Supply and providing plate earthing as per IS 3043 with
300x300x6.00 mm copper earth plate, 20 mm GI watering pipe
fixed to the earth plate with 20 x 3 mm GI clamps, GI funnel
with weld mesh, filling required quantity of charcoal including
construction of inspection chamber with a bed concrete of 1:4:8
PCC using 40 mm broken stone (10 cm thick), brick work in
cement mortar 1:6, plastering the surface of brick masonry and
the exposed surface of PCC bed with cement mortar 1:4, 12 mm
thick, (the finished inside dimension shall be 300 x 300 x 300
mm) but excluding test joint, earth continuity conductor to the
plate, and covering at the top. (in ordinary soil)
E 4730.00
733 Supply and providing plate earthing as per IS 3043 with
300x300x6.00 mm copper earth plate, 20 mm GI watering pipe
fixed to the earth plate with 20 x 3 mm GI clamps, GI funnel
with weld mesh, filling required quantity of charcoal including
construction of inspection chamber with a bed concrete of 1:4:8
PCC using 40 mm broken stone (10 cm thick), brick work in
cement mortar 1:6, plastering the surface of brick masonry and
the exposed surface of PCC bed with cement mortar 1:4, 12 mm
thick, (the finished inside dimension shall be 300 x 300 x 300
mm) but excluding test joint, earth continuity conductor to the
plate, and covering at the top. (in hard soil)
E 4803.00
734 Supply and providing plate earthing as per IS 3043 with
300x300x6.00 mm copper earth plate, 20 mm GI watering pipe
fixed to the earth plate with 20 x 3 mm GI clamps, GI funnel
with weld mesh, filling required quantity of charcoal including
construction of inspection chamber with a bed concrete of 1:4:8
PCC using 40 mm broken stone (10 cm thick), brick work in
cement mortar 1:6, plastering the surface of brick masonry and
the exposed surface of PCC bed with cement mortar 1:4, 12 mm
thick, (the finished inside dimension shall be 300 x 300 x 300
mm) but excluding test joint, earth continuity conductor to the
plate, and covering at the top. (in ordinary rock - soft laterite
soil) E 4982.00
735 Supply and providing plate earthing as per IS 3043 with
300x300x3.00 mm copper earth plate, 20 mm GI watering pipe
fixed to the earth plate with 20 x 3 mm GI clamps, GI funnel
with weld mesh, filling required quantity of charcoal including
construction of inspection chamber with a bed concrete of 1:4:8
PCC using 40 mm broken stone (10 cm thick), brick work in
cement mortar 1:6, plastering the surface of brick masonry and
the exposed surface of PCC bed with cement mortar 1:4, 12 mm
thick, (the finished inside dimension shall be 300 x 300 x 300
mm) but excluding test joint, earth continuity conductor to the
plate, and covering at the top. (in ordinary soil)
E 3040.00
736 Supply and providing plate earthing as per IS 3043 with
300x300x3.00 mm copper earth plate, 20 mm GI watering pipe
fixed to the earth plate with 20 x 3 mm GI clamps, GI funnel
with weld mesh, filling required quantity of charcoal including
construction of inspection chamber with a bed concrete of 1:4:8
PCC using 40 mm broken stone (10 cm thick), brick work in
cement mortar 1:6, plastering the surface of brick masonry and
the exposed surface of PCC bed with cement mortar 1:4, 12 mm
thick, (the finished inside dimension shall be 300 x 300 x 300
mm) but excluding test joint, earth continuity conductor to the
plate, and covering at the top. (in hard soil)
E 3114.00
737 Supply and providing plate earthing as per IS 3043 with
300x300x3.00 mm copper earth plate, 20 mm GI watering pipe
fixed to the earth plate with 20 x 3 mm GI clamps, GI funnel
with weld mesh, filling required quantity of charcoal including
construction of inspection chamber with a bed concrete of 1:4:8
PCC using 40 mm broken stone (10 cm thick), brick work in
cement mortar 1:6, plastering the surface of brick masonry and
the exposed surface of PCC bed with cement mortar 1:4, 12 mm
thick, (the finished inside dimension shall be 300 x 300 x 300
mm) but excluding test joint, earth continuity conductor to the
plate, and covering at the top. (in ordinary rock - soft laterite
soil) E 3292.00
738 Supply and providing pipe earthing as per IS 3043 with 3.60 m
long 40 mm dia B class GI pipe, GI funnel with weld mesh,
filling required quantity of charcoal & salt including construction
of inspection chamber with a bed concrete of 1:4:8 PCC using 40
mm broken stone (10 cm thick), brick work in cement mortar 1:6,
plastering the surface of brick masonry and the exposed surface
of PCC bed with cement mortar 1:4, 12 mm thick, (the finished
inside dimension shall be 300 x 300 x 300 mm) but excluding test
joint, earth continuity conductor to the plate, and covering at the
top. (in ordinary soil)
E 2256.00
739 Supply and providing pipe earthing as per IS 3043 with 3.60 m
long 40 mm dia B class GI pipe, GI funnel with weld mesh,
filling required quantity of charcoal & salt including construction
of inspection chamber with a bed concrete of 1:4:8 PCC using 40
mm broken stone (10 cm thick), brick work in cement mortar 1:6,
plastering the surface of brick masonry and the exposed surface
of PCC bed with cement mortar 1:4, 12 mm thick, (the finished
inside dimension shall be 300 x 300 x 300 mm) but excluding test
joint, earth continuity conductor to the plate, and covering at the
top. (in hard soil)
E 2311.00
740 Supply and providing pipe earthing as per IS 3043 with 3.60 m
long 40 mm dia B class GI pipe, GI funnel with weld mesh,
filling required quantity of charcoal & salt including construction
of inspection chamber with a bed concrete of 1:4:8 PCC using 40
mm broken stone (10 cm thick), brick work in cement mortar 1:6,
plastering the surface of brick masonry and the exposed surface
of PCC bed with cement mortar 1:4, 12 mm thick, (the finished
inside dimension shall be 300 x 300 x 300 mm) but excluding test
joint, earth continuity conductor to the plate, and covering at the
top. (in ordinary rocky - soft laterite soil)
E 2564.00
741 Supply and providing the following sizes of cast iron gully trap
with covering at the top of the inspection chamber of earth pit as
required
a 300 x 300 x 6 mm cast iron gully trap with covering E 244.00
b 300 x 300 x 10 mm cast iron gully trap with covering E 366.00
c 450 x 450 x 10 mm cast iron gully trap with covering E 854.00
742 Supply and providing RCC covering slab constructed with the
following for the inspection chamber of earth pit as required

a Cement concrete 1:2:4 using 20mm (nominal size) broken stone


for reinforced concrete work m3 5065.00
b Cement concrete 1:3:6 using 20mm (nominal size) broken stone
for reinforced concrete work . m3 4448.00
c Reinforcement for R.C.C works , bend tied and placed in position
(plain grill requiring bend cold) using Tor steel Kg 60.00
d Plastering with cement mortar 1:4, 12mm thick one coat. m2 143.00
743 Supply and providing test joint for the earthing system using 2
Nos of the following sizes of strips including cutting and bending
to shape, drilling necessary holes and fixed to the watering pipe
etc as required.

a1 2 x 25 x 3 mm GI strip m 124.00
a2 2 x 32 x 3 mm GI strip m 144.00
a3 2 x 40 x 3 mm GI strip m 168.00
a4 2 x 50 x 3 mm GI strip m 197.00
a5 2 x 65 x 3 mm GI strip m 233.00

b1 2 x 25 x 6 mm GI strip m 192.00
b2 2 x 32 x 6 mm GI strip m 230.00
b3 2 x 40 x 6 mm GI strip m 283.00
b4 2 x 50 x 6 mm GI strip m 331.00
b5 2 x 65 x 6 mm GI strip m 402.00

c1 2 x 25 x 3 mm tinned copper strip m 487.00


c2 2 x 32 x 3 mm tinned copper strip m 610.00
c3 2 x 40 x 3 mm tinned copper strip m 743.00
c4 2 x 50 x 3 mm tinned copper strip m 917.00
c5 2 x 65 x 3 mm tinned copper strip m 1168.00

d1 2 x 25 x 6 mm tinned copper strip m 895.00


d2 2 x 32 x 6 mm tinned copper strip m 1137.00
d3 2 x 40 x 6 mm tinned copper strip m 1413.00
d4 2 x 50 x 6 mm tinned copper strip m 1752.00
d5 2 x 65 x 6 mm tinned copper strip m 2247.00
744 Supply and providing earth lead from the test joint to the earth
electrode using the following sizes of conductors/ strips
including cutting, drilling necessary holes (in case of strip) and
fixing firmly with plate test joint etc as required.

a1 3.15 mm bare copper conductor (10 SWG) m 46.00


a2 4.00 mm bare copper conductor (8 SWG) m 71.00
a3 4.75 mm bare copper conductor (6 SWG) m 101.00
a4 6.00 mm bare copper conductor (4 SWG) m 147.00
a5 7.10 mm bare copper conductor (2 SWG) m 209.00
a6 8.00 mm bare copper conductor (0 SWG) m 286.00

b1 4.00 mm bare GI conductor (8 SWG) m 11.40


b2 4.75 mm bare GI conductor (6 SWG) m 16.70

c1 25 x 3 mm copper strip tinned at the points of contacts m 406.00


c2 32 x 3 mm copper strip tinned at the points of contacts m 326.00
c3 40 x 3 mm copper strip tinned at the points of contacts m 1007.00
c4 50 x 3 mm copper strip tinned at the points of contacts m 807.00
c5 65 x 3 mm copper strip tinned at the points of contacts m 1047.00

d1 25 x 6 mm copper strip tinned at the points of contacts m 806.00


d2 32 x 6 mm copper strip tinned at the points of contacts m 1030.00
d3 40 x 6 mm copper strip tinned at the points of contacts m 1288.00
d4 50 x 6 mm copper strip tinned at the points of contacts m 1610.00
d5 65 x 6 mm copper strip tinned at the points of contacts m 2092.00

e1 25 x 3 mm GI strip m 64.00
e2 32 x 3 mm GI strip m 81.00

f1 25 x 6 mm GI strip m 123.00
f2 32 x 6 mm GI strip m 158.00
f3 40 x 6 mm GI strip m 197.00
f4 50 x 6 mm GI strip m 246.00
f5 65 x 6 mm GI strip m 317.00
SUPPLY & DRAWING EARTH CONDUCTORS
750 Supply and drawing bare earthing conductors of the following
sizes along with wiring/ cables and giving connection as required.

a1 2.00 mm copper conductor (14 SWG) m 17.50


a2 2.65 mm copper conductor (12 SWG) m 34.00
a3 3.15 mm copper conductor (10 SWG) m 50.50
a4 4.00 mm copper conductor (8 SWG) m 78.50
a5 4.75 mm copper conductor (6 SWG) m 109.00
a6 6.00 mm copper conductor (4 SWG) m 156.00
a7 7.10 mm copper conductor (2 SWG) m 217.00
a8 8.00 mm copper conductor (0 SWG) m 296.00

b1 2.65 mm GI conductor (12 SWG) m 8.90


b2 3.15 mm GI conductor (10 SWG) m 12.20
b3 4.00 mm GI conductor (8 SWG) m 19.00
b4 4.75 mm GI conductor (6 SWG) m 23.50
751 Supply and laying bare earthing conductors of the following sizes
laid 0.6 m below ground level including excavating trench of
suitable size and refilling etc. as required (in ordinary soil).

a1 3.15 mm copper conductor (10 SWG) m 61.00


a2 4.00 mm copper conductor (8 SWG) m 86.50
a3 4.75 mm copper conductor (6 SWG) m 117.00
a4 6.00 mm copper conductor (4 SWG) m 163.00
a5 7.10 mm copper conductor (2 SWG) m 225.00
a6 8.00 mm copper conductor (0 SWG) m 303.00

b1 3.15 mm GI conductor (10 SWG) m 23.00


b2 4.00 mm GI conductor (8 SWG) m 27.00
b3 4.75 mm GI conductor (6 SWG) m 32.00
752 Supply and laying bare earthing conductors of the following sizes
laid 0.6 m below ground level including excavating trench of
suitable size and refilling etc. as required (in hard soil).

a1 3.15 mm copper conductor (10 SWG) m 75.00


a2 4.00 mm copper conductor (8 SWG) m 100.00
a3 4.75 mm copper conductor (6 SWG) m 131.00
a4 6.00 mm copper conductor (4 SWG) m 177.00
a5 7.10 mm copper conductor (2 SWG) m 238.00
a6 8.00 mm copper conductor (0 SWG) m 317.00

b1 3.15 mm GI conductor (10 SWG) m 37.00


b2 4.00 mm GI conductor (8 SWG) m 40.50
b3 4.75 mm GI conductor (6 SWG) m 45.50
753 Supply and laying bare earthing conductors of the following sizes
laid 0.6 m below ground level including excavating trench of
suitable size and refilling etc. as required (in ordinary rocky - soft
laterite soil).

a1 3.15 mm copper conductor (10 SWG) m 101.00


a2 4.00 mm copper conductor (8 SWG) m 126.00
a3 4.75 mm copper conductor (6 SWG) m 157.00
a4 6.00 mm copper conductor (4 SWG) m 203.00
a5 7.10 mm copper conductor (2 SWG) m 264.00
a6 8.00 mm copper conductor (0 SWG) m 343.00

b1 3.15 mm GI conductor (10 SWG) m 63.00


b2 4.00 mm GI conductor (8 SWG) m 66.50
b3 4.75 mm GI conductor (6 SWG) m 71.50
754 Supply and laying strips of the following sizes along with wiring/
cables and giving connection as required.
a1 25 x 3 mm GI strip m 62.00
a2 25 x 6 mm GI strip m 121.00
a3 32 x 3 mm GI strip m 78.00
a4 32 x 6 mm GI strip m 155.00
a5 40 x 6 mm GI strip m 194.00
a6 50 x 6 mm GI strip m 241.00
a7 65 x 6 mm GI strip m 313.00

b1 20 x 3 mm copper strip tinned at the points of contacts m 325.00


b2 25 x 3 mm copper strip tinned at the points of contacts m 406.00
b3 25 x 6 mm copper strip tinned at the points of contacts m 809.00
b4 32 x 3 mm copper strip tinned at the points of contacts m 508.00
b5 32 x 6 mm copper strip tinned at the points of contacts m 1035.00
b6 40 x 3 mm copper strip tinned at the points of contacts m 648.00
b7 40 x 6 mm copper strip tinned at the points of contacts m 1294.00
b8 50 x 3 mm copper strip tinned at the points of contacts m 810.00
b9 50 x 6 mm copper strip tinned at the points of contacts m 1616.00
b10 65 x 3 mm copper strip tinned at the points of contacts m 1052.00
b11 65 x 6 mm copper strip tinned at the points of contacts m 2101.00
755 Supply and laying the following sizes of strips laid 0.60 m below
ground level including excavating trench of suitable size and
refilling etc. as required (in ordinary soil).
a1 25 x 3 mm GI strip m 77.50
a2 25 x 6 mm GI strip m 137.00
a3 32 x 3 mm GI strip m 94.00
a4 32 x 6 mm GI strip m 171.00
a5 40 x 6 mm GI strip m 210.00
a6 50 x 6 mm GI strip m 257.00
a7 65 x 6 mm GI strip m 329.00

b1 20 x 3 mm copper strip tinned at the points of contacts m 341.00


b2 25 x 3 mm copper strip tinned at the points of contacts m 422.00
b3 25 x 6 mm copper strip tinned at the points of contacts m 825.00
b4 32 x 3 mm copper strip tinned at the points of contacts m 534.00
b5 32 x 6 mm copper strip tinned at the points of contacts m 1051.00
b6 40 x 3 mm copper strip tinned at the points of contacts m 664.00
b7 40 x 6 mm copper strip tinned at the points of contacts m 1310.00
b8 50 x 3 mm copper strip tinned at the points of contacts m 826.00
b9 50 x 6 mm copper strip tinned at the points of contacts m 1632.00
b10 65 x 3 mm copper strip tinned at the points of contacts m 1068.00
b11 65 x 6 mm copper strip tinned at the points of contacts m 2117.00
756 Supply and laying the following sizes of strips laid 0.60 m below
ground level including excavating trench of suitable size and
refilling etc. as required (in hard soil).
a1 25 x 3 mm GI strip m 91.50
a2 25 x 6 mm GI strip m 151.00
a3 32 x 3 mm GI strip m 108.00
a4 32 x 6 mm GI strip m 185.00
a5 40 x 6 mm GI strip m 223.00
a6 50 x 6 mm GI strip m 271.00
a7 65 x 6 mm GI strip m 343.00

b1 20 x 3 mm copper strip tinned at the points of contacts m 354.00


b2 25 x 3 mm copper strip tinned at the points of contacts m 435.00
b3 25 x 6 mm copper strip tinned at the points of contacts m 839.00
b4 32 x 3 mm copper strip tinned at the points of contacts m 548.00
b5 32 x 6 mm copper strip tinned at the points of contacts m 1065.00
b6 40 x 3 mm copper strip tinned at the points of contacts m 678.00
b7 40 x 6 mm copper strip tinned at the points of contacts m 1323.00
b8 50 x 3 mm copper strip tinned at the points of contacts m 840.00
b9 50 x 6 mm copper strip tinned at the points of contacts m 1646.00
b10 65 x 3 mm copper strip tinned at the points of contacts m 1082.00
b11 65 x 6 mm copper strip tinned at the points of contacts m 2130.00
757 Supply and laying the following sizes of strips laid 0.60 m below
ground level including excavating trench of suitable size and
refilling etc. as required (in ordinary rocky - soft laterite soil).

a1 25 x 3 mm GI strip m 118.00
a2 25 x 6 mm GI strip m 177.00
a3 32 x 3 mm GI strip m 134.00
a4 32 x 6 mm GI strip m 211.00
a5 40 x 6 mm GI strip m 249.00
a6 50 x 6 mm GI strip m 297.00
a7 65 x 6 mm GI strip m 369.00

b1 20 x 3 mm copper strip tinned at the points of contacts m 380.00


b2 25 x 3 mm copper strip tinned at the points of contacts m 461.00
b3 25 x 6 mm copper strip tinned at the points of contacts m 865.00
b4 32 x 3 mm copper strip tinned at the points of contacts m 574.00
b5 32 x 6 mm copper strip tinned at the points of contacts m 1091.00
b6 40 x 3 mm copper strip tinned at the points of contacts m 704.00
b7 40 x 6 mm copper strip tinned at the points of contacts m 1349.00
b8 50 x 3 mm copper strip tinned at the points of contacts m 866.00
b9 50 x 6 mm copper strip tinned at the points of contacts m 1672.00
b10 65 x 3 mm copper strip tinned at the points of contacts m 1108.00
b11 65 x 6 mm copper strip tinned at the points of contacts m 2156.00
758 Supply and clamping the following sizes of strips on surface of
wall/ parapet/ existing cable tray using clamps fabricated from 20
x 3 mm GI flat duly painted or heavy duty GI spacer saddles,
spacing of clamps not exceeding 1m, making good the damages,
colour washing etc. as required (for horizontal run).
a1 20 x 3 mm GI strip m 86.00
a2 25 x 3 mm GI strip m 98.50
a3 25 x 6 mm GI strip m 159.00
a4 32 x 3 mm GI strip m 116.00
a5 32 x 6 mm GI strip m 197.00
a6 40 x 6 mm GI strip m 239.00
a7 50 x 6 mm GI strip m 289.00
a8 65 x 6 mm GI strip m 358.00

b1 20 x 3 mm copper strip tinned at the points of contacts m 360.00


b2 25 x 3 mm copper strip tinned at the points of contacts m 441.00
b3 25 x 6 mm copper strip tinned at the points of contacts m 845.00
b4 32 x 3 mm copper strip tinned at the points of contacts m 554.00
b5 32 x 6 mm copper strip tinned at the points of contacts m 1073.00
b6 40 x 3 mm copper strip tinned at the points of contacts m 686.00
b7 40 x 6 mm copper strip tinned at the points of contacts m 1335.00
b8 50 x 3 mm copper strip tinned at the points of contacts m 851.00
b9 50 x 6 mm copper strip tinned at the points of contacts m 1661.00
b10 65 x 6 mm copper strip tinned at the points of contacts m 2149.00

c1 20 x 3 mm aluminium strip m 87.50


c2 25 x 3 mm aluminium strip m 101.00
c3 25 x 6 mm aluminium strip m 163.00
c4 32 x 6 mm aluminium strip m 198.00
c5 40 x 6 mm aluminium strip m 238.00
c6 50 x 6 mm aluminium strip m 289.00
c7 65 x 6 mm aluminium strip m 364.00
759 Supply and clamping the following sizes of strips on surface of
wall/ parapet/ existing cable tray using clamps fabricated from 20
x 3 mm GI flat duly painted or heavy duty GI spacer saddles,
spacing of clamps not exceeding 1m, making good the damages,
colour washing etc. as required (for vertical run).

a1 20 x 3 mm GI strip m 109.00
a2 25 x 3 mm GI strip m 122.00
a3 25 x 6 mm GI strip m 182.00

b1 20 x 3 mm copper strip tinned at the points of contacts m 387.00


b2 25 x 3 mm copper strip tinned at the points of contacts m 469.00
b3 25 x 6 mm copper strip tinned at the points of contacts m 877.00

c1 20 x 3 mm aluminium strip m 111.00


c2 25 x 3 mm aluminium strip m 124.00
c3 25 x 6 mm aluminium strip m 186.00
c4 32 x 3 mm aluminium strip m 141.00
c5 32 x 6 mm aluminium strip m 221.00
SOCKETS FOR earthing CONDUCTORS
765 supply of superior quality copper earth socket for the following
sizes of earth conductor including crimping etc. as required.

a 2.00 mm (14 SWG) E 13.50


b 2.65 mm (12 SWG) E 14.00
c 3.15 mm (10 SWG) E 15.50
d 4.00 mm (8 SWG) E 18.50
e 4.75 mm (6 SWG) E 26.00
f 6.00 mm (4 SWG) E 29.00
g 7.10 mm (2 SWG) E 36.00
h 8.00 mm (0 SWG) E 36.00
766 Supply and providing the following sizes of bolt and nut with
washers on the existing MS box / earth bus etc. as required
including drilling necessary holes as required
a1 12 x 3 mm brass bolt & nut E 8.00
a2 25 x 3mm brass bolt & nut E 12.20
a3 25 x 6 mm brass bolt & nut E 15.40

b1 25 x 6 mm GI bolt & nut E 7.00


b2 25 x 8 mm GI bolt & nut E 7.90
b3 30 x 8 mm GI bolt & nut E 8.00
b4 30 x 10 mm GI bolt & nut E 11.10
b5 35 x 10 mm GI bolt & nut E 11.40
SH: PROTECTIVE PIPES TO EARTH LEADS
770 Supplying , threading , laying and jointing of the following sizes
of 'B' class GI pipe with all required accessories in ground in the
existing trench as protective covering to earth leads.
.
a 15 mm dia m 68.00
b 20 mm dia m 87.00
c 25 mm dia m 119.00
d 32 mm dia m 147.00
e 40 mm dia m 175.00
f 50 mm dia m 247.00
g 65 mm dia m 297.00
h 75 mm dia m 404.00
771 Supply and clamping the following sizes of "B" class GI pipe on
wall with all required accessories & clamps etc., including cutting
and making good the walls, painting the exposed portions etc., as
protective covering to earth leads / cables.

a 15 mm dia m 86.00
b 20 mm dia m 105.00
c 25 mm dia m 153.00
d 32 mm dia m 173.00
e 40 mm dia m 201.00
f 50 mm dia m 274.00
g 65 mm dia m 322.00
h 75 mm dia m 430.00
PART XVI
SH: LIGHTNING PROTECTION SYSTEM
775 Riveting , sweating and soldering of one GI/ aluminium/ copper
tape with another GI/ aluminium/ copper tape using 2 nos. 6mm
dia. GI bolt and nut/ rivets including drilling holes, tinning etc. as
required.
E 34.00
776 Providing and fixing testing joint made of 2 no. strips as
mentioned below of the following sizes provided on either side of
the conductors with 4 nos of GI bolts, nuts check nuts and spring
washers etc. complete as required (for down conductors).

a1 2 Nos 20 x 3 mm copper strip 150mm long E 120.00


a2 2 Nos 25 x 3 mm copper strip 150mm long E 155.00
a3 2 Nos 25 x 6 mm copper strip 150mm long E 281.00

b1 2 Nos 25 x 6 mm lead strip 150mm long E 344.00


b2 2 Nos 32 x 6 mm lead strip 150mm long E 427.00

c1 2 Nos 20x3 mm GI strip 150mm long E 44.50


c2 2 Nos 25x3 mm GI strip 150mm long E 52.00
c3 2 Nos 25x6 mm GI strip 150mm long E 71.00
c4 2 Nos 32x3 mm GI strip 150mm long E 63.00
c5 2 Nos 32x6 mm GI strip 150mm long E 93.00
777 Supplying, threading, laying, jointing & clamping of the
following sizes of PVC pipe (8 Kgf/ cm2) with all required
accessories and clamp including cutting and making good the
walls, colour washing etc. on surface of wall / parapet etc. as
required.

a 32 mm dia m 42.00
b 40 mm dia m 53.00
PART XVII
SH: PANEL BOARDS
800 Fabrication, supply, conveyance, installation testing and
commissioning of floor or wall mounting, dust and vermin proof,
cubicle type MV panel board comprising of the following
components/ devices & complying to IS 8623.

801 Fabrication of fully partitioned, dust and vermin proof enclosure


for panel assembly as per form 4 of IS 8623 (with latest
amendments) using 2.00 mm CRCA sheet as per approved design
and requirement, with front and rear access facility, bus bar
chambers, hinged doors for all switch gear compartments,
earthing the doors using 4 sq mm braided copper conductor,
providing necessary cut-outs for mounting meters, relays,
indication lamps, bus bar interconnection etc, detachable covers
for bus bar chamber and cable alley, powder coating the assembly
after subjecting to 7 tank process etc as required. CRCA sheet
alone be used for the fabrication. Angles/ flats/ slotted angles etc
shall not be used for the fabrication of panel assembly.
m3 35124.00
802 Fabrication of fully partitioned, dust and vermin proof enclosure
for panel assembly as per form 4 of IS 8623 (with latest
amendments) using 2.00 mm CRCA sheet as per approved design
and requirement, with front and rear access facility, bus bar
chambers, hinged doors for all switch gear compartments,
earthing the doors using 4 sq mm braided copper conductor,
providing necessary cut-outs for mounting meters, relays,
indication lamps, bus bar interconnection etc, detachable covers
for bus bar chamber and cable alley, painting the assembly with 2
coats of best quality synthetic enamel paint over a coat of zinc
chromate primer etc as required. CRCA sheet alone be used for
the fabrication. Angles/ flats/ slotted angles etc shall not be used
for the fabrication of panel assembly.

m3 29639.00
803 Fabrication of fully partitioned, dust and vermin proof enclosure
for panel assembly as per form 4 of IS 8623 (with latest
amendments) using 1.60 mm CRCA sheet as per approved design
and requirement, with front and rear access facility, bus bar
chambers, hinged doors for all switch gear compartments,
earthing the doors using 4 sq mm braided copper conductor,
providing necessary cut-outs for mounting meters, relays,
indication lamps, bus bar interconnection etc, detachable covers
for bus bar chamber and cable alley, powder coating the assembly
after subjecting to 7 tank process etc as required. CRCA sheet
alone be used for the fabrication. Angles/ flats/ slotted angles etc
shall not be used for the fabrication of panel assembly.
m3 31104.00
804 Fabrication of fully partitioned, dust and vermin proof enclosure
for panel assembly as per form 4 of IS 8623 (with latest
amendments) using 1.60 mm CRCA sheet as per approved design
and requirement, with front and rear access facility, bus bar
chambers, hinged doors for all switch gear compartments,
earthing the doors using 4 sq mm braided copper conductor,
providing necessary cut-outs for mounting meters, relays,
indication lamps, bus bar interconnection etc, detachable covers
for bus bar chamber and cable alley, painting the assembly with 2
coats synthetic enamel paint over a coat of zinc chromate primer
etc as required. CRCA sheet alone be used for the fabrication.
Angles/ flats/ slotted angles etc shall not be used for the
fabrication of panel assembly.

m3 25620.00
805 Supply and providing the following size of SMC sheets in the
panel as barriers & shrouding using required bolts and nuts
including cutting to shape etc., as required.
a 2 mm thick m2 2740.00
b 3 mm thick m2 3658.00
c 4 mm thick m 2
4673.00
d 5 mm thick m2 5832.00
e 6 mm thick m 2
7176.00
806 Supply and providing the following sizes of SMC sheets as
support to the extended terminations of switch gears in the
outgoing side in the panel using required bolts and nuts including
cutting to shape etc., as required.

a 8 mm thick m2 9225.00
b 10 mm thick m 2
11394.00
c 12 mm thick m2 13769.00
d 16 mm thick m2 18169.00
807 Supply and fixing the following types of beeding along the
periphery of doors/ other detachable compartments to make the
panel assembly dust & vermin proof including sticking with glue

a A' section neoprene beeding suitable for 1.60/ 2.00 mm sheet


m 49.00
b U' section rubber beeding suitable for 1.60/ 2.00 mm sheet m 7.00
c U' section PVC beeding suitable for 1.60/ 2.00 mm sheet m 4.50
d 40 x 3 mm neoprene flat beeding m 84.00
808 Fabrication, supply, conveyance and installation of base frame
for floor mounting type panel board using channel of class
designation ISMC 75 including cutting, welding, drilling holes,
painting with two coats of synthetic enamel paint over a coat of
zinc chromate primer, bolting the frame to the panel and to the
finished floor using required bolt and nuts, making good the
damages etc. as required.
m 612.00
809 Fabrication, supply, conveyance and installation of angle iron
frame work for wall mounting panel board using suitable size
angle iron cut and welded to shape including painting with two
coats of synthetic enamel paint over a coat of zinc chromate
primer, bolting the frame to the panel using required bolt and
nuts, fixing the whole to the wall, making good the damages etc.
as required.
Kg 95.50
810 Fabrication, supply & fixing main bus bar system and
interconnections with electrolytic grade copper strips/ rigid
conductors conforming to IS 1867 (with latest amendments) for
bus bar arrangement with single strip per phase supported on
finger type bus bar supports of adequate size, spacing between
supports not exceeding 50 cm & overhang not exceeding 5 cm
including bending to shape, drilling holes, tinning the points of
contacts, fixing heat shrinkable PVC sleeves, plated bolts and
nuts with plate washers and spring washers, copper sockets for
round conductors, etc., as required.
cm2 5.90
811 Fabrication, supply & fixing earth bus system with copper strip/
conductor and connecting all accessories as per rule including g
tinning the points of contacts etc as required
cm2 5.60
SUPPLY AND FIXING CONTROL GEARS
820 Supply, conveyance and fixing the following types & current
rated control gears & switchgears conforming to IS 13947
suitable for 440 V, 50 Hz, AC supply in the existing panel
assembly as required

ACB
a1 800 A, 3 pole, manual draw out type ACB with thermal magnetic
release and OL & SC protection E 92249.00
a2 1000 A, 3 pole, manual draw out type ACB with thermal
magnetic release and OL & SC protection E 99226.00
a3 1250 A, 3 pole, manual draw out type ACB with thermal
magnetic release and OL & SC protection E 123038.00
a4 1600 A, 3 pole, manual draw out type ACB with thermal
magnetic release and OL & SC protection E 138606.00
a5 2000 A, 3 pole, manual draw out type ACB with thermal
magnetic release and OL & SC protection E 167401.00
a6 2500 A, 3 pole, manual draw out type ACB with thermal
magnetic release and OL & SC protection E 196529.00
a7 3200 A, 3 pole, manual draw out type ACB with thermal
magnetic release and OL & SC protection E 150567.00

b1 800 A, 3 pole, electrical draw out type ACB with thermal


magnetic release and OL & SC protection E 127193.00
b2 1000 A, 3 pole, electrical draw out type ACB with thermal
magnetic release and OL & SC protection E 131397.00
b3 1250 A, 3 pole, electrical draw out type ACB with thermal
magnetic release and OL & SC protection E 157168.00
b4 1600 A, 3 pole, electrical draw out type ACB with thermal
magnetic release and OL & SC protection E 171609.00
b5 2000 A, 3 pole, electrical draw out type ACB with thermal
magnetic release and OL & SC protection E 200146.00
b6 2500 A, 3 pole, electrical draw out type ACB with thermal
magnetic release and OL & SC protection E 224922.00
b7 3200 A, 3 pole, electrical draw out type ACB with thermal
magnetic release and OL & SC protection E 287749.00

c1 800 A, 4 pole, manual draw out type ACB with thermal magnetic
release and OL & SC protection E 119783.00
c2 1000 A, 4 pole, manual draw out type ACB with thermal
magnetic release and OL & SC protection E 128576.00
c3 1250 A, 4 pole, manual draw out type ACB with thermal
magnetic release and OL & SC protection E 160251.00
c4 1600 A, 4 pole, manual draw out type ACB with thermal
magnetic release and OL & SC protection E 178476.00
c5 2000 A, 4 pole, manual draw out type ACB with thermal
magnetic release and OL & SC protection E 216761.00
c6 2500 A, 4 pole, manual draw out type ACB with thermal
magnetic release and OL & SC protection E 255671.00
c7 3200 A, 4 pole, manual draw out type ACB with thermal
magnetic release and OL & SC protection E 314707.00

d1 800 A, 4 pole, electrical draw out type ACB with thermal


magnetic release and OL & SC protection E 164831.00
d2 1000 A, 4 pole, electrical draw out type ACB with thermal
magnetic release and OL & SC protection E 172510.00
d3 1250 A, 4 pole, electrical draw out type ACB with thermal
magnetic release and OL & SC protection E 206681.00
d4 1600 A, 4 pole, electrical draw out type ACB with thermal
magnetic release and OL & SC protection E 222994.00
d5 2000 A, 4 pole, electrical draw out type ACB with thermal
magnetic release and OL & SC protection E 262617.00
d6 2500 A, 4 pole, electrical draw out type ACB with thermal
magnetic release and OL & SC protection E 291222.00
d7 3200 A, 4 pole, electrical draw out type ACB with thermal
magnetic release and OL & SC protection E 349322.00

e1 800 A, 3 pole, manual draw out type microprocessor based ACB


with overload, instantaneous SC, delayed SC and ground fault
protection E 109271.00
e2 1000 A, 3 pole, manual draw out type microprocessor based ACB
with overload, instantaneous SC, delayed SC and ground fault E 115556.00
protection
e3 1250 A, 3 pole, manual draw out type microprocessor based ACB
with overload, instantaneous SC, delayed SC and ground fault E 139650.00
protection
e4 1600 A, 3 pole, manual draw out type microprocessor based ACB
with overload, instantaneous SC, delayed SC and ground fault E 152283.00
e5 protection
2000 A, 3 pole, manual draw out type microprocessor based ACB
with overload, instantaneous SC, delayed SC and ground fault E 181615.00
protection
e6 2500 A, 3 pole, manual draw out type microprocessor based ACB
with overload, instantaneous SC, delayed SC and ground fault E 209899.00
protection
e7 3200 A, 3 pole, manual draw out type microprocessor based ACB
with overload, instantaneous SC, delayed SC and ground fault E 271705.00
protection
f1 800 A, 3 pole, electrical draw out type microprocessor based
ACB with overload, instantaneous SC, delayed SC and ground E 142793.00
fault protection
f2 1000 A, 3 pole, electrical draw out type microprocessor based
ACB with overload, instantaneous SC, delayed SC and ground E 149078.00
fault protection
f3 1250 A, 3 pole, electrical draw out type microprocessor based
ACB with overload, instantaneous SC, delayed SC and ground E 173172.00
fault protection
f4 1600 A, 3 pole, electrical draw out type microprocessor based
ACB with overload, instantaneous SC, delayed SC and ground E 185805.00
fault protection
f5 2000 A, 3 pole, electrical draw out type microprocessor based
ACB with overload, instantaneous SC, delayed SC and ground E 215136.00
fault protection
f6 2500 A, 3 pole, electrical draw out type microprocessor based
ACB with overload, instantaneous SC, delayed SC and ground E 243421.00
fault protection
f7 3200 A, 3 pole, electrical draw out type microprocessor based
ACB with overload, instantaneous SC, delayed SC and ground E 305226.00
fault protection
g1 800 A, 4 pole, manual draw out type microprocessor based ACB
with overload, instantaneous SC, delayed SC and ground fault
protection E 128259.00
g2 1000 A, 4 pole, manual draw out type microprocessor based ACB
with overload, instantaneous SC, delayed SC and ground fault E 132317.00
protection
g3 1250 A, 4 pole, manual draw out type microprocessor based ACB
with overload, instantaneous SC, delayed SC and ground fault E 164792.00
g4 protection
1600 A, 4 pole, manual draw out type microprocessor based ACB
with overload, instantaneous SC, delayed SC and ground fault E 174386.00
protection
g5 2000 A, 4 pole, manual draw out type microprocessor based ACB
with overload, instantaneous SC, delayed SC and ground fault E 209060.00
protection
g6 2500 A, 4 pole, manual draw out type microprocessor based ACB
with overload, instantaneous SC, delayed SC and ground fault E 247506.00
protection
g7 3200 A, 4 pole, manual draw out type microprocessor based ACB
with overload, instantaneous SC, delayed SC and ground fault E 302608.00
protection
h1 800 A, 4 pole, electrical draw out type microprocessor based
ACB with overload, instantaneous SC, delayed SC and ground E 173172.00
h2 fault
1000 protection
A, 4 pole, electrical draw out type microprocessor based
ACB with overload, instantaneous SC, delayed SC and ground E 180154.00
fault protection
h3 1250 A, 4 pole, electrical draw out type microprocessor based
ACB with overload, instantaneous SC, delayed SC and ground E 204180.00
fault protection
h4 1600 A, 4 pole, electrical draw out type microprocessor based
ACB with overload, instantaneous SC, delayed SC and ground E 225926.00
fault
h5 2000 protection
A, 4 pole, electrical draw out type microprocessor based
ACB with overload, instantaneous SC, delayed SC and ground E 258925.00
fault protection
h6 2500 A, 4 pole, electrical draw out type microprocessor based
ACB with overload, instantaneous SC, delayed SC and ground E 289304.00
fault protection
h7 3200 A, 4 pole, electrical draw out type microprocessor based
ACB with overload, instantaneous SC, delayed SC and ground E 339796.00
fault protection
i1 800 A, 3 pole, manual draw out type microprocessor based ACB
having advanced protection with power monitoring and
communication facilities E 129960.00
i2 1000 A, 3 pole, manual draw out type microprocessor based ACB
having advanced protection with power monitoring and
communication facilities
E 134830.00
i3 1250 A, 3 pole, manual draw out type microprocessor based ACB
having advanced protection with power monitoring and
communication facilities E 159135.00
i4 1600 A, 3 pole, manual draw out type microprocessor based ACB
having advanced protection with power monitoring and
communication facilities
E 179467.00
i5 2000 A, 3 pole, manual draw out type microprocessor based ACB
having advanced protection with power monitoring and
communication facilities
E 200995.00
i6 2500 A, 3 pole, manual draw out type microprocessor based ACB
having advanced protection with power monitoring and
communication facilities E 254891.00
i7 3200 A, 3 pole, manual draw out type microprocessor based ACB
having advanced protection with power monitoring and
communication facilities
E 269515.00

j1 800 A, 3 pole, electrical draw out type microprocessor based


ACB having advanced protection with power monitoring and
communication facilities
E 166625.00
j2 1000 A, 3 pole, electrical draw out type microprocessor based
ACB having advanced protection with power monitoring and
communication facilities
E 171495.00
j3 1250 A, 3 pole, electrical draw out type microprocessor based
ACB having advanced protection with power monitoring and
communication facilities
E 195800.00
j4 1600 A, 3 pole, electrical draw out type microprocessor based
ACB having advanced protection with power monitoring and
communication facilities
E 216132.00
j5 2000 A, 3 pole, electrical draw out type microprocessor based
ACB having advanced protection with power monitoring and
communication facilities E 237660.00
j6 2500 A, 3 pole, electrical draw out type microprocessor based
ACB having advanced protection with power monitoring and
communication facilities
E 239178.00
j7 3200 A, 3 pole, electrical draw out type microprocessor based
ACB having advanced protection with power monitoring and
communication facilities E 306180.00

k1 800 A, 4 pole, manual draw out type microprocessor based ACB


having advanced protection with power monitoring and
communication facilities E 161072.00
k2 1000 A, 4 pole, manual draw out type microprocessor based ACB
having advanced protection with power monitoring and
communication facilities
E 167148.00
k3 1250 A, 4 pole, manual draw out type microprocessor based ACB
having advanced protection with power monitoring and
communication facilities E 197527.00
k4 1600 A, 4 pole, manual draw out type microprocessor based ACB
having advanced protection with power monitoring and
communication facilities
E 222940.00
k5 2000 A, 4 pole, manual draw out type microprocessor based ACB
having advanced protection with power monitoring and
communication facilities
E 249863.00
k6 2500 A, 4 pole, manual draw out type microprocessor based ACB
having advanced protection with power monitoring and
communication facilities E 317220.00
k7 3200 A, 4 pole, manual draw out type microprocessor based ACB
having advanced protection with power monitoring and
communication facilities
E 335501.00

l1 800 A, 4 pole, electrical draw out type microprocessor based


ACB having advanced protection with power monitoring and
communication facilities
E 197737.00
l2 1000 A, 4 pole, electrical draw out type microprocessor based
ACB having advanced protection with power monitoring and
communication facilities
E 203985.00
l3 1250 A, 4 pole, electrical draw out type microprocessor based
ACB having advanced protection with power monitoring and
communication facilities
E 234192.00
l4 1600 A, 4 pole, electrical draw out type microprocessor based
ACB having advanced protection with power monitoring and
communication facilities
E 259605.00
l5 2000 A, 4 pole, electrical draw out type microprocessor based
ACB having advanced protection with power monitoring and
communication facilities E 286527.00
l6 2500 A, 4 pole, electrical draw out type microprocessor based
ACB having advanced protection with power monitoring and
communication facilities
E 353885.00
l7 3200 A, 4 pole, electrical draw out type microprocessor based
ACB having advanced protection with power monitoring and
communication facilities E 372166.00
821 ACCESSORIES FOR ACB
a Shunt release E 2183.00
b Instantaneous UV release E 2906.00
c UV release with time delay of 0.2 to 3.2 sec E 5574.00
d Motorised operating mechanism E 31657.00
e 630/ - CT for 3P & 4P circuit breakers for neutral overload &
ground fault protection. E 2173.00
f 800/ - CT for 3P & 4P circuit breakers for neutral overload &
ground fault protection. E 2173.00
g 1000/ - CT for 3P & 4P circuit breakers for neutral overload &
ground fault protection. E 2173.00
h 1250/ - CT for 3P & 4P circuit breakers for neutral overload &
ground fault protection. E 2173.00
i 1600/ - CT for 3P & 4P circuit breakers for neutral overload &
ground fault protection. E 2173.00
j 2000/ - CT for 3P & 4P circuit breakers for neutral overload &
ground fault protection. E 2173.00
k Mutual mechanical inter-lock E 11085.00
l Castel key & pad lock combination E 1992.00
825 MCCB WITH THERMAL MAGNETIC RELEASE
MCCB - 16 KA 3 pole
a1 16 A, 16 kA (Ics=100%Icu), 3 pole, current limiting type MCCB
having thermal setting range of 80 - 100% with thermal magnetic
release having adjustable OL & SC E 4389.00
a2 20 A, 16 kA (Ics=100%Icu), 3 pole, current limiting type MCCB
having thermal setting range of 80 - 100% with thermal magnetic
release having adjustable OL & SC E 4389.00
a3 25 A, 16 kA (Ics=100%Icu), 3 pole, current limiting type MCCB
having thermal setting range of 80 - 100% with thermal magnetic
release having adjustable OL & SC E 4389.00
a4 32 A, 16 kA (Ics=100%Icu), 3 pole, current limiting type MCCB
having thermal setting range of 80 - 100% with thermal magnetic
release having adjustable OL & SC E 4389.00
a5 40 A, 16 kA (Ics=100%Icu), 3 pole, current limiting type MCCB
having thermal setting range of 80 - 100% with thermal magnetic
release having adjustable OL & SC E 4389.00
a6 50 A, 16 kA (Ics=100%Icu), 3 pole, current limiting type MCCB
having thermal setting range of 80 - 100% with thermal magnetic
release having adjustable OL & SC E 4389.00
a7 63 A, 16 kA (Ics=100%Icu), 3 pole, current limiting type MCCB
having thermal setting range of 80 - 100% with thermal magnetic
release having adjustable OL & SC E 4389.00
a8 80 A, 16 kA (Ics=100%Icu), 3 pole, current limiting type MCCB
having thermal setting range of 80 - 100% with thermal magnetic
release having adjustable OL & SC E 4389.00
a9 100 A, 16 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC E 4389.00
a10 125 A, 16 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC E 5520.00
a11 160 A, 16 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC E 6908.00
MCCB - 16 kA 4 pole
b1 16 A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB
having thermal setting range of 80 - 100% with thermal magnetic
release having adjustable OL & SC E 5462.00
b2 20 A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB
having thermal setting range of 80 - 100% with thermal magnetic
release having adjustable OL & SC E 5462.00
b3 25 A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB
having thermal setting range of 80 - 100% with thermal magnetic
release having adjustable OL & SC E 5462.00
b4 32 A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB
having thermal setting range of 80 - 100% with thermal magnetic
release having adjustable OL & SC E 5462.00
b5 40 A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB
having thermal setting range of 80 - 100% with thermal magnetic
release having adjustable OL & SC E 5462.00
b6 50 A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB
having thermal setting range of 80 - 100% with thermal magnetic
release having adjustable OL & SC E 5462.00
b7 63 A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB
having thermal setting range of 80 - 100% with thermal magnetic
release having adjustable OL & SC E 5462.00
b8 80 A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB
having thermal setting range of 80 - 100% with thermal magnetic
release having adjustable OL & SC E 5462.00
b9 100 A, 16 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC E 5462.00
b10 125 A, 16 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC E 6855.00
b11 160 A, 16 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC E 8583.00
MCCB - 25 kA 3 pole
c1 16 A, 25 kA (Ics=100%Icu), 3 pole, current limiting type MCCB
having thermal setting range of 80 - 100% with thermal magnetic
release having adjustable OL & SC E 4624.00
c2 20 A, 25 kA (Ics=100%Icu), 3 pole, current limiting type MCCB
having thermal setting range of 80 - 100% with thermal magnetic
release having adjustable OL & SC E 4624.00
c3 25 A, 25 kA (Ics=100%Icu), 3 pole, current limiting type MCCB
having thermal setting range of 80 - 100% with thermal magnetic
release having adjustable OL & SC E 5148.00
c4 32 A, 25 kA (Ics=100%Icu), 3 pole, current limiting type MCCB
having thermal setting range of 80 - 100% with thermal magnetic
release having adjustable OL & SC E 5148.00
c5 40 A, 25 kA (Ics=100%Icu), 3 pole, current limiting type MCCB
having thermal setting range of 80 - 100% with thermal magnetic
release having adjustable OL & SC E 5148.00
c6 50 A, 25 kA (Ics=100%Icu), 3 pole, current limiting type MCCB
having thermal setting range of 80 - 100% with thermal magnetic
release having adjustable OL & SC E 5148.00
c7 63 A, 25 kA (Ics=100%Icu), 3 pole, current limiting type MCCB
having thermal setting range of 80 - 100% with thermal magnetic
release having adjustable OL & SC E 5148.00
c8 80 A, 25 kA (Ics=100%Icu), 3 pole, current limiting type MCCB
having thermal setting range of 80 - 100% with thermal magnetic
release having adjustable OL & SC E 5148.00
c9 100 A, 25 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC E 5148.00
c10 125 A, 25 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC E 6436.00
c11 160 A, 25 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC E 8060.00
MCCB - 25 kA 4 pole
d1 16 A, 25 kA (Ics=100%Icu), 4 pole, current limiting type MCCB
having thermal setting range of 80 - 100% with thermal magnetic
release having adjustable OL & SC E 6091.00
d2 20 A, 25 kA (Ics=100%Icu), 4 pole, current limiting type MCCB
having thermal setting range of 80 - 100% with thermal magnetic
release having adjustable OL & SC E 6091.00
d3 25 A, 25 kA (Ics=100%Icu), 4 pole, current limiting type MCCB
having thermal setting range of 80 - 100% with thermal magnetic
release having adjustable OL & SC E 6405.00
d4 32 A, 25 kA (Ics=100%Icu), 4 pole, current limiting type MCCB
having thermal setting range of 80 - 100% with thermal magnetic
release having adjustable OL & SC E 6405.00
d5 40 A, 25 kA (Ics=100%Icu), 4 pole, current limiting type MCCB
having thermal setting range of 80 - 100% with thermal magnetic
release having adjustable OL & SC E 6405.00
d6 50 A, 25 kA (Ics=100%Icu), 4 pole, current limiting type MCCB
having thermal setting range of 80 - 100% with thermal magnetic
release having adjustable OL & SC E 6405.00
d7 63 A, 25 kA (Ics=100%Icu), 4 pole, current limiting type MCCB
having thermal setting range of 80 - 100% with thermal magnetic
release having adjustable OL & SC E 6405.00
d8 80 A, 25 kA (Ics=100%Icu), 4 pole, current limiting type MCCB
having thermal setting range of 80 - 100% with thermal magnetic
release having adjustable OL & SC E 6405.00
d9 100 A, 25 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC E 6405.00
d10 125 A, 25 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC E 8034.00
d11 160 A, 25 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC E 10051.00
MCCB - 35 kA 3 pole
e1 1.6/ 2/ 2.5/ 3.2/ 4/ 5/ 6.3/ 8/ 10/ 12.5/ 16/ 20/ 25/ 32/ 40A, 35 kA
(Ics=100%Icu), 3 pole, current limiting type MCCB having
thermal setting range of 80 - 100% with thermal magnetic release
having adjustable OL & SC
E 8081.00
e2 50 A, 35 kA (Ics=100%Icu), 3 pole, current limiting type MCCB
having thermal setting range of 80 - 100% with thermal magnetic
release having adjustable OL & SC E 6720.00
e3 63 A, 35 kA (Ics=100%Icu), 3 pole, current limiting type MCCB
having thermal setting range of 80 - 100% with thermal magnetic
release having adjustable OL & SC E 6720.00
e4 80 A, 35 kA (Ics=100%Icu), 3 pole, current limiting type MCCB
having thermal setting range of 80 - 100% with thermal magnetic
release having adjustable OL & SC E 7100.00
e5 100 A, 35 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC E 7100.00
e6 125 A, 35 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC E 7470.00
e7 160 A, 35 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC E 9439.00
e8 200 A, 35 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC E 16706.00
e9 250 A, 35 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC E 16706.00
e10 320 A, 35 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC E 20194.00
e11 400 A, 35 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC E 20225.00
e12 500 A, 35 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC E 23137.00
e13 630 A, 35 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC E 25914.00
MCCB - 35 kA 4 pole
f1 1.6/ 2/ 2.5/ 3.2/ 4/ 5/ 6.3/ 8/ 10/ 12.5/ 16/ 20/ 25/ 32/ 40/ 50/ 63/
80/ 100A, 35 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC
E 10072.00
f2 125 A, 35 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC E 10888.00
f3 160 A, 35 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC E 13481.00
f4 200 A, 35 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC E 18094.00
f5 250 A, 35 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC E 18126.00
f6 320 A, 35 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC E 25196.00
f7 400 A, 35 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC E 25227.00
f8 500 A, 35 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC E 28873.00
f9 630 A, 35 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC E 32329.00
MCCB - 50/55 kA 3 pole
g1 1.6/ 2/ 2.5/ 3.2/ 4/ 5/ 6.3/ 8/ 10/ 12.5/ 16/ 20/ 25/ 32/ 40/ 50/ 63/
80/ 100A A, 50/55 kA (Ics=100%Icu), 3 pole, current limiting
type MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC (Group B)

E 9286.00
g2 125 A, 50/55 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC (Group B)
E 11489.00
g3 160 A, 50/55 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC (Group B)
E 14031.00
g4 200 A, 50/55 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC (Group B)
E 18906.00
g5 250 A, 50/55 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC (Group B)
E 18937.00
g6 320 A, 50/55 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC (Group B)
E 21346.00
g7 400 A, 50/55 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC (Group B)
E 21377.00
g8 500 A, 50/55 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC (Group B)
E 25310.00
g9 630 A, 50/55 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC (Group B)
26698.00
MCCB - 50/55 kA 4 pole (Group B)
h1 1.6/ 2/ 2.5/ 3.2/ 4/ 5/ 6.3/ 8/ 10/ 12.5/ 16/ 20/ 25/ 32/ 40/ 50/ 63/
80/ 100A, 50/55 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC (Group B)

E 11590.00
h2 125 A, 50/55 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC (Group B)
E 14371.00
h3 160 A, 50/55 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC (Group B)
E 17566.00
h4 200 A, 50/55 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC (Group B)
E 23567.00
h5 250 A, 50/55 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC (Group B)
E 23598.00
h6 320 A, 50/55 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC (Group B)
E 26601.00
h7 400 A, 50/55 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC (Group B)
E 26601.00
h8 500 A, 50/55 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC (Group B)
E 31502.00
h9 630 A, 50/55 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC (Group B)
E 33262.00
MCCB - 70 kA 3 pole
i1 1.6/ 2/ 2.5/ 3.2/ 4/ 5/ 6.3/ 8/ 10/ 12.5/ 16/ 20/ 25/ 32/ 40/ 50/ 63/
80/ 100A, 70 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC
E 10570.00
i2 125 A, 70 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC E 13010.00
i3 160 A, 70 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC E 16205.00
i4 200 A, 70 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC E 21210.00
i5 250 A, 70 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC E 21241.00
i6 320 A, 70 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC E 22498.00
i7 400 A, 70 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC E 22529.00
i8 500 A, 70 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC E 27851.00
i9 630 A, 70 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC E 29396.00
MCCB - 70 kA 4 pole
j1 1.6/ 2/ 2.5/ 3.2/ 4/ 5/ 6.3/ 8/ 10/ 12.5/ 16/ 20/ 25/ 32/ 40/ 50/ 63/
80/ 100A, 70 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC
E 13188.00
j2 125 A, 70 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC E 16230.00
j3 160 A, 70 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC E 20133.00
j4 200 A, 70 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC E 26500.00
j5 250 A, 70 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC E 26532.00
j6 320 A, 70 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC E 27658.00
j7 400 A, 70 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC E 28108.00
j8 500 A, 70 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC E 34725.00
j9 630 A, 70 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB having thermal setting range of 80 - 100% with thermal
magnetic release having adjustable OL & SC E 36624.00
826 MICROPROCESSOR BASED MCCB
MCCB - 35/36 kA 3 pole ( Microprocessor based )
a1 10/ 25/ 40/ 63/ 100A, 35/36 kA (Ics=100%Icu), 3 pole, current
limiting type MCCB with microprocessor based release with
overload setting of 50 - 100% having adjustable OL & SC
E 9273.00
a2 160 A, 35/36 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with microprocessor based release with overload setting
of 50 - 100% having adjustable OL & SC E 11605.00
a3 250 A, 35/36 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with microprocessor based release with overload setting
of 50 - 100% having adjustable OL & SC E 22153.00
a4 320 A, 35/36 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with microprocessor based release with overload setting
of 50 - 100% having adjustable OL & SC E 22678.00
a5 400 A, 35/36 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with microprocessor based release with overload setting
of 50 - 100% having adjustable OL & SC E 23117.00
a6 500 A, 35/36 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with microprocessor based release with overload setting
of 50 - 100% having adjustable OL & SC E 24773.00
a7 630 A, 35/36 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with microprocessor based release with overload setting
of 50 - 100% having adjustable OL & SC E 51747.00
MCCB - 35/36 kA 4 pole ( Microprocessor based )
b1 10/ 25/ 63/ 100A, 35/36 kA (Ics=100%Icu), 4 pole, current
limiting type MCCB with microprocessor based release with
overload setting of 50 - 100% having adjustable OL & SC
E 12522.00
b2 160 A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB with microprocessor based release with overload setting
of 50 - 100% having adjustable OL & SC E 16884.00
b3 250 A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB with microprocessor based release with overload setting
of 50 - 100% having adjustable OL & SC E 26553.00
b4 320 A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB with microprocessor based release with overload setting
of 50 - 100% having adjustable OL & SC E 27308.00
b5 400 A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB with microprocessor based release with overload setting
of 50 - 100% having adjustable OL & SC E 28334.00
b6 500 A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB with microprocessor based release with overload setting
of 50 - 100% having adjustable OL & SC E 30922.00
b7 630 A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB with microprocessor based release with overload setting
of 50 - 100% having adjustable OL & SC E 57482.00
MCCB - 50/55 kA 3 pole ( Microprocessor based )
c1 10 A, 50/55 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with microprocessor based release with thermal setting of
50 - 100% having adjustable OL & SC E 15761.00
c2 25 A, 50/55 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with microprocessor based release with thermal setting of
50 - 100% having adjustable OL & SC E 15761.00
c3 40 A, 50/55 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with microprocessor based release with thermal setting of
50 - 100% having adjustable OL & SC E 21994.00
c4 63 A, 50/55 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with microprocessor based release with thermal setting of
50 - 100% having adjustable OL & SC E 15761.00
c5 100 A, 50/55 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with microprocessor based release with thermal setting of
50 - 100% having adjustable OL & SC E 15761.00
c6 125 A, 50/55 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with microprocessor based release with thermal setting of
50 - 100% having adjustable OL & SC E 22582.00
c7 160 A, 50/55 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with microprocessor based release with thermal setting of
50 - 100% having adjustable OL & SC E 21691.00
c8 250 A, 50/55 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with microprocessor based release with thermal setting of
50 - 100% having adjustable OL & SC E 23785.00
c9 320 A, 50/55 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with microprocessor based release with thermal setting of
50 - 100% having adjustable OL & SC E 24620.00
c10 400 A, 50/55 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with microprocessor based release with thermal setting of
50 - 100% having adjustable OL & SC E 25393.00
c11 500 A, 50/55 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with microprocessor based release with thermal setting of
50 - 100% having adjustable OL & SC E 27620.00
c12 630 A, 50/55 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with microprocessor based release with thermal setting of
50 - 100% having adjustable OL & SC E 29775.00
MCCB - 50/55 kA 4 pole ( Microprocessor based )
d1 10/ 25/ 63/ 100/ 125A, 50/55 kA (Ics=100%Icu), 4 pole, current
limiting type MCCB with microprocessor based release with
thermal setting of 50 - 100% having adjustable OL & SC
E 19290.00
d2 160 A, 50/55 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB with microprocessor based release with thermal setting of
50 - 100% having adjustable OL & SC E 26497.00
d3 250 A, 50/55 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB with microprocessor based release with thermal setting of
50 - 100% having adjustable OL & SC E 28365.00
d4 320 A, 50/55 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB with microprocessor based release with thermal setting of
50 - 100% having adjustable OL & SC E 28942.00
d5 400 A, 50/55 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB with microprocessor based release with thermal setting of
50 - 100% having adjustable OL & SC E 29837.00
d6 500 A, 50/55 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB with microprocessor based release with thermal setting of
50 - 100% having adjustable OL & SC E 32429.00
d7 630 A, 50/55 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB with microprocessor based release with thermal setting of
50 - 100% having adjustable OL & SC E 50798.00
MCCB -70 kA 3 pole ( Microprocessor based )
e1 10/ 25/ 63A, 70 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with microprocessor based release with thermal setting of
50 - 100% having adjustable OL & SC E 16095.00
e2 100 A, 70 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with microprocessor based release with thermal setting of
50 - 100% having adjustable OL & SC E 16095.00
e3 160 A, 70 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with microprocessor based release with thermal setting of
50 - 100% having adjustable OL & SC E 21547.00
e4 200 A, 70 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with microprocessor based release with thermal setting of
50 - 100% having adjustable OL & SC E 26396.00
e5 250 A, 70 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with microprocessor based release with thermal setting of
50 - 100% having adjustable OL & SC E 26427.00
e6 320 A, 70 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with microprocessor based release with thermal setting of
50 - 100% having adjustable OL & SC E 26532.00
e7 400 A, 70 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with microprocessor based release with thermal setting of
50 - 100% having adjustable OL & SC E 27139.00
e8 500 A, 70 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with microprocessor based release with thermal setting of
50 - 100% having adjustable OL & SC E 29680.00
e9 630 A, 70 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with microprocessor based release with thermal setting of
50 - 100% having adjustable OL & SC E 61268.00
MCCB -70 kA 4 pole ( Microprocessor based )
f1 10/ 25/ 63/ 100A, 70 kA (Ics=100%Icu), 4 pole, current limiting
type MCCB with microprocessor based release with thermal
setting of 50 - 100% having adjustable OL & SC
E 20809.00
f2 160 A, 70 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB with microprocessor based release with thermal setting of
50 - 100% having adjustable OL & SC E 27989.00
f3 250 A, 70 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB with microprocessor based release with thermal setting of
50 - 100% having adjustable OL & SC E 32031.00
f4 320 A, 70 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB with microprocessor based release with thermal setting of
50 - 100% having adjustable OL & SC E 33132.00
f5 400 A, 70 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB with microprocessor based release with thermal setting of
50 - 100% having adjustable OL & SC E 33870.00
f6 500 A, 70 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB with microprocessor based release with thermal setting of
50 - 100% having adjustable OL & SC E 37038.00
f7 630 A, 70 kA (Ics=100%Icu), 4 pole, current limiting type
MCCB with microprocessor based release with thermal setting of
50 - 100% having adjustable OL & SC E 66689.00
827 MOTORISED MCCB WITH THERMAL MAGNETIC
RELEASE
MCCB - 16 kA 3 pole
a1 16 A, 16 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 18687.00
a2 20 A, 16 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 18687.00
a3 25 A, 16 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 18687.00
a4 32 A, 16 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 18687.00
a5 40 A, 16 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 18687.00
a6 50 A, 16 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 18687.00
a7 63 A, 16 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 18687.00
a8 80 A, 16 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 18687.00
a9 100 A, 16 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 18687.00
a10 160 A, 16 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 19818.00
MCCB - 16 kA 4 pole
b1 16 A, 16 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 19762.00
b2 20 A, 16 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 19762.00
b3 25 A, 16 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 19762.00
b4 32 A, 16 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 19762.00
b5 40 A, 16 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 19762.00
b6 50 A, 16 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 19762.00
b7 63 A, 16 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 19762.00
b8 80 A, 16 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 19762.00
b9 100 A, 16 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 19762.00
b10 125 A, 16 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 21154.00
b11 160 A, 16 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 22883.00
MCCB - 25 kA 3 pole
c1 16 A, 25 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 23480.00
c2 20 A, 25 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 23480.00
c3 25 A, 25 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 19448.00
c4 32 A, 25 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 19448.00
c5 40 A, 25 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 19448.00
c6 50 A, 25 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 19448.00
c7 63 A, 25 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 19448.00
c8 80 A, 25 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 19448.00
c9 100 A, 25 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 19448.00
c10 125 A, 25 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 20736.00
c11 160 A, 25 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 22359.00
MCCB - 25 kA 4 pole
d1 16 A, 25 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 21994.00
d2 20 A, 25 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 21994.00
d3 25 A, 25 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 21994.00
d4 32 A, 25 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 21994.00
d5 40 A, 25 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 21994.00
d6 50 A, 25 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 21994.00
d7 63 A, 25 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 21994.00
d8 80 A, 25 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 21994.00
d9 100 A, 25 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 21994.00
d10 125 A, 25 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 23722.00
d11 160 A, 25 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 25865.00
MCCB - 35 kA 3 pole
e1 1.6/ 2/ 2.5/ 3.2/ 4/ 5/ 6.3/ 8/ 10/ 12.5/ 16/ 20/ 25/ 32/ 40/ 50/ 63/
80/ 100A, 35 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC

E 22380.00
e2 125 A, 35 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 23040.00
e3 160 A, 35 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 24873.00
e4 200 A, 35 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 31002.00
e5 250 A, 35 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 31002.00
e6 320 A, 35 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 44357.00
e7 400 A, 35 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 44357.00
e8 500 A, 35 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 47238.00
e9 630 A, 35 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC 50015.00
MCCB - 35 kA 4 pole
f1 1.6/ 2/ 2.5/ 3.2/ 4/ 5/ 6.3/ 8/ 10/ 12.5/ 16/ 20/ 25/ 32/ 40/ 50/ 63/
80/ 100A, 35 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC

E 24370.00
f2 125 A, 35 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 25187.00
f3 160 A, 35 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 27780.00
f4 200 A, 35 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 32389.00
f5 250 A, 35 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 32389.00
f6 320 A, 35 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 49360.00
f7 400 A, 35 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 49360.00
f8 500 A, 35 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 52974.00
f9 630 A, 35 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC 56430.00
MCCB - 50/55 kA 3 pole (Group B)
g1 1.6/ 2/ 2.5/ 3.2/ 4/ 5/ 6.3/ 8/ 10/ 12.5/ 16/ 20/ 25/ 32/ 40/ 50/ 63/
80/ 100A, 50/55 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC

E 23584.00
g2 125 A, 50/55 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 25816.00
g3 160 A, 50/55 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 28330.00
g4 200 A, 50/55 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 33202.00
g5 250 A, 50/55 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 33202.00
g6 320 A, 50/55 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 45510.00
g7 400 A, 50/55 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 45510.00
g8 500 A, 50/55 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 49413.00
g9 630 A, 50/55 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 50800.00
MCCB - 50/55 kA 4 pole
h1 1.6/ 2/ 2.5/ 3.2/ 4/ 5/ 6.3/ 8/ 10/ 12.5/ 16/ 20/ 25/ 32/ 40/ 50/ 63/
80/ 100A, 50/55 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC

E 25890.00
h2 125 A, 50/55 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 28666.00
h3 160 A, 50/55 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 31866.00
h4 200 A, 50/55 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 37863.00
h5 250 A, 50/55 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 37863.00
h6 320 A, 50/55 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 50800.00
h7 400 A, 50/55 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 50800.00
h8 500 A, 50/55 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 55698.00
h9 630 A, 50/55 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB having thermal setting range of 80 - 100% with
thermal magnetic release having adjustable OL & SC E 57426.00
MCCB - 70 kA 3 pole
i1 1.6/ 2/ 2.5/ 3.2/ 4/ 5/ 6.3/ 8/ 10/ 12.5/ 16/ 20/ 25/ 32/ 40/ 50/ 63/
80/ 100A, 70 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB having thermal setting range of 70 - 100% with
thermal magnetic release having adjustable OL & SC

E 24843.00
i2 125 A, 70 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB having thermal setting range of 70 - 100% with
thermal magnetic release having adjustable OL & SC E 27308.00
i3 160 A, 70 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB having thermal setting range of 70 - 100% with
thermal magnetic release having adjustable OL & SC E 30425.00
i4 200 A, 70 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB having thermal setting range of 70 - 100% with
thermal magnetic release having adjustable OL & SC E 35510.00
i5 250 A, 70 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB having thermal setting range of 70 - 100% with
thermal magnetic release having adjustable OL & SC E 35541.00
i6 320 A, 70 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB having thermal setting range of 70 - 100% with
thermal magnetic release having adjustable OL & SC E 46666.00
i7 400 A, 70 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB having thermal setting range of 70 - 100% with
thermal magnetic release having adjustable OL & SC E 46728.00
i8 500 A, 70 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB having thermal setting range of 70 - 100% with
thermal magnetic release having adjustable OL & SC E 52509.00
i9 630 A, 70 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB having thermal setting range of 70 - 100% with
thermal magnetic release having adjustable OL & SC E 58168.00
MCCB - 70 kA 4 pole
j1 1.6/ 2/ 2.5/ 3.2/ 4/ 5/ 6.3/ 8/ 10/ 12.5/ 16/ 20/ 25/ 32/ 40/ 50/ 63/
80/ 100A, 70 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB having thermal setting range of 70 - 100% with
thermal magnetic release having adjustable OL & SC

E 27487.00
j2 125 A, 70 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB having thermal setting range of 70 - 100% with
thermal magnetic release having adjustable OL & SC E 30530.00
j3 160 A, 70 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB having thermal setting range of 70 - 100% with
thermal magnetic release having adjustable OL & SC E 34432.00
j4 200 A, 70 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB having thermal setting range of 70 - 100% with
thermal magnetic release having adjustable OL & SC E 40800.00
j5 250 A, 70 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB having thermal setting range of 70 - 100% with
thermal magnetic release having adjustable OL & SC E 40831.00
j6 320 A, 70 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB having thermal setting range of 70 - 100% with
thermal magnetic release having adjustable OL & SC E 51857.00
j7 400 A, 70 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB having thermal setting range of 70 - 100% with
thermal magnetic release having adjustable OL & SC E 52307.00
j8 500 A, 70 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB having thermal setting range of 70 - 100% with
thermal magnetic release having adjustable OL & SC E 58964.00
j9 630 A, 70 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB having thermal setting range of 70 - 100% with
thermal magnetic release having adjustable OL & SC E 60823.00
828 MOTORISED MCCB WITH MICROPROCESSOR BASED
RELEASE
MCCB - 35/36 kA 3 pole ( Microprocessor based )
a1 10/ 25/ 40/ 63/ 100A, 35/36 kA (Ics=100%Icu), 3 pole, current
limiting type motorised MCCB with microprocessor based
release with overload setting of 50 - 100% having adjustable OL
& SC
E 26597.00
a2 160 A, 35/36 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB with microprocessor based release with
overload setting of 50 - 100% having adjustable OL & SC E 30714.00
a3 250 A, 35/36 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB with microprocessor based release with
overload setting of 50 - 100% having adjustable OL & SC E 36484.00
a4 320 A, 35/36 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB with microprocessor based release with
overload setting of 50 - 100% having adjustable OL & SC E 46872.00
a5 400 A, 35/36 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB with microprocessor based release with
overload setting of 50 - 100% having adjustable OL & SC E 47431.00
a6 500 A, 35/36 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB with microprocessor based release with
overload setting of 50 - 100% having adjustable OL & SC E 48967.00
a7 630 A, 35/36 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB with microprocessor based release with
overload setting of 50 - 100% having adjustable OL & SC E 75976.00
MCCB - 35/36 kA 4 pole ( Microprocessor based )
b1 10/ 25/ 63/ 100A, 35/36 kA (Ics=100%Icu), 4 pole, current
limiting type motorised MCCB with microprocessor based
release with overload setting of 50 - 100% having adjustable OL
& SC
E 30289.00
b2 160 A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB with microprocessor based release with
overload setting of 50 - 100% having adjustable OL & SC E 35611.00
b3 250 A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB with microprocessor based release with
overload setting of 50 - 100% having adjustable OL & SC E 40884.00
b4 320 A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB with microprocessor based release with
overload setting of 50 - 100% having adjustable OL & SC E 51508.00
b5 400 A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB with microprocessor based release with
overload setting of 50 - 100% having adjustable OL & SC E 52564.00
b6 500 A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB with microprocessor based release with
overload setting of 50 - 100% having adjustable OL & SC E 55121.00
b7 630 A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB with microprocessor based release with
overload setting of 50 - 100% having adjustable OL & SC E 81712.00
MCCB - 50/55 kA 3 pole ( Microprocessor based )
c1 10/ 25/ 40/ 63/ 100A, 50/55 kA (Ics=100%Icu), 3 pole, current
limiting type motorised MCCB with microprocessor based
release with thermal setting of 50 - 100% having adjustable OL
& SC E 29137.00
c2 125 A, 50/55 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB with microprocessor based release with
thermal setting of 50 - 100% having adjustable OL & SC E 34720.00
c3 160 A, 50/55 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB with microprocessor based release with
thermal setting of 50 - 100% having adjustable OL & SC E 34720.00
c4 250 A, 50/55 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB with microprocessor based release with
thermal setting of 50 - 100% having adjustable OL & SC E 36693.00
c5 320 A, 50/55 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB with microprocessor based release with
thermal setting of 50 - 100% having adjustable OL & SC E 36693.00
c6 400 A, 50/55 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB with microprocessor based release with
thermal setting of 50 - 100% having adjustable OL & SC E 47409.00
c7 500 A, 50/55 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB with microprocessor based release with
thermal setting of 50 - 100% having adjustable OL & SC E 48116.00
c8 630 A, 50/55 kA (Ics=100%Icu), 3 pole, current limiting type
motorised MCCB with microprocessor based release with
thermal setting of 50 - 100% having adjustable OL & SC E 48147.00
MCCB - 50/55 kA 4 pole ( Microprocessor based )
d1 10/ 25/ 63/ 100A, 50/55 kA (Ics=100%Icu), 4 pole, current
limiting type motorised MCCB with microprocessor based
release with thermal setting of 50 - 100% having adjustable OL
& SC
E 47889.00
d2 125 A, 50/55 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB with microprocessor based release with
thermal setting of 50 - 100% having adjustable OL & SC E 51533.00
d3 160 A, 50/55 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB with microprocessor based release with
thermal setting of 50 - 100% having adjustable OL & SC E 55096.00
d4 200 A, 50/55 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB with microprocessor based release with
thermal setting of 50 - 100% having adjustable OL & SC E 56100.00
d5 250 A, 50/55 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB with microprocessor based release with
thermal setting of 50 - 100% having adjustable OL & SC E 56963.00
d6 320 A, 50/55 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB with microprocessor based release with
thermal setting of 50 - 100% having adjustable OL & SC E 77339.00
d7 400 A, 50/55 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB with microprocessor based release with
thermal setting of 50 - 100% having adjustable OL & SC E 78234.00
d8 500 A, 50/55 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB with microprocessor based release with
thermal setting of 50 - 100% having adjustable OL & SC E 80827.00
d9 630 A, 50/55 kA (Ics=100%Icu), 4 pole, current limiting type
motorised MCCB with microprocessor based release with
thermal setting of 50 - 100% having adjustable OL & SC E 108383.00
MCCB -70 kA 3/4 pole ( Microprocessor based )
e1 10/ 25/ 63/ 100A, 70 kA (Ics=100%Icu), 3/4 pole, current
limiting type motorised MCCB with microprocessor based
release with thermal setting of 50 - 100% having adjustable OL
& SC
E 30394.00
e2 160 A, 70 kA (Ics=100%Icu), 3/4 pole, current limiting type
motorised MCCB with microprocessor based release with
thermal setting of 50 - 100% having adjustable OL & SC E 35847.00
e3 200 A, 70 kA (Ics=100%Icu), 3/4 pole, current limiting type
motorised MCCB with microprocessor based release with
thermal setting of 50 - 100% having adjustable OL & SC E 40691.00
e4 250 A, 70 kA (Ics=100%Icu), 3/4 pole, current limiting type
motorised MCCB with microprocessor based release with
thermal setting of 50 - 100% having adjustable OL & SC E 40727.00
e5 320 A, 70 kA (Ics=100%Icu), 3/4 pole, current limiting type
motorised MCCB with microprocessor based release with
thermal setting of 50 - 100% having adjustable OL & SC E 50730.00
e6 400 A, 70 kA (Ics=100%Icu), 3/4 pole, current limiting type
motorised MCCB with microprocessor based release with
thermal setting of 50 - 100% having adjustable OL & SC E 51338.00
e7 500 A, 70 kA (Ics=100%Icu), 3/4 pole, current limiting type
motorised MCCB with microprocessor based release with
thermal setting of 50 - 100% having adjustable OL & SC E 53878.00
e8 630 A, 70 kA (Ics=100%Icu), 3/4 pole, current limiting type
motorised MCCB with microprocessor based release with
thermal setting of 50 - 100% having adjustable OL & SC E 85466.00
829 3 POLE MCCB WITH ONLY SC PROTECTION FOR MOTOR
STARTERS
35 kA, 3 pole
a1 1.00 A, 35 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with only SC protection for motor starter E 9102.00
a2 1.60 A, 35 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with only SC protection for motor starter E 9102.00
a3 2.00 A, 35 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with only SC protection for motor starter E 9102.00
a4 2.50 A, 35 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with only SC protection for motor starter E 9102.00
a5 3.20 A, 35 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with only SC protection for motor starter E 9102.00
a6 4.00 A, 35 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with only SC protection for motor starter E 9102.00
a7 5.00 A, 35 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with only SC protection for motor starter E 9102.00
a8 6.50A, 35 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with only SC protection for motor starter E 9102.00
a9 8.50 A, 35 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with only SC protection for motor starter E 9102.00
a10 11 A, 35 kA (Ics=100%Icu), 3 pole, current limiting type MCCB
with only SC protection for motor starter E 9102.00
a11 12.50 A, 35 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with only SC protection for motor starter E 9102.00
a12 20 A, 35 kA (Ics=100%Icu), 3 pole, current limiting type MCCB
with only SC protection for motor starter E 9102.00
a13 32 A, 35 kA (Ics=100%Icu), 3 pole, current limiting type MCCB
with only SC protection for motor starter E 9102.00
a14 52 A, 35 kA (Ics=100%Icu), 3 pole, current limiting type MCCB
with only SC protection for motor starter E 9102.00
a15 80 A, 35 kA (Ics=100%Icu), 3 pole, current limiting type MCCB
with only SC protection for motor starter E 9102.00
a16 100 A, 35 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with only SC protection for motor starter E 9102.00
a17 125 A, 35 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with only SC protection for motor starter E 9997.00
a18 160 A, 35 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with only SC protection for motor starter E 10992.00
a19 200 A, 35 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with only SC protection for motor starter E 10997.00
a20 400 A, 35 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with only SC protection for motor starter E 25358.00
50 kA, 3 pole
b1 1.00 A, 50 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with only SC protection for motor starter E 10072.00
b2 1.60 A, 50 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with only SC protection for motor starter E 10072.00
b3 2.00 A, 50 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with only SC protection for motor starter E 10072.00
b4 2.50 A, 50 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with only SC protection for motor starter E 10072.00
b5 3.20 A, 50 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with only SC protection for motor starter E 10072.00
b6 4.00 A, 50 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with only SC protection for motor starter E 10072.00
b7 5.00 A, 50 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with only SC protection for motor starter E 10072.00
b8 6.50A, 50 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with only SC protection for motor starter E 10072.00
b9 8.50 A, 50 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with only SC protection for motor starter E 10072.00
b10 11 A, 50 kA (Ics=100%Icu), 3 pole, current limiting type MCCB
with only SC protection for motor starter E 10072.00
b11 12.50 A, 50 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with only SC protection for motor starter E 10072.00
b12 20 A, 50 kA (Ics=100%Icu), 3 pole, current limiting type MCCB
with only SC protection for motor starter E 10072.00
b13 32 A, 50 kA (Ics=100%Icu), 3 pole, current limiting type MCCB
with only SC protection for motor starter E 10072.00
b14 52 A, 50 kA (Ics=100%Icu), 3 pole, current limiting type MCCB
with only SC protection for motor starter E 10072.00
b15 80 A, 50 kA (Ics=100%Icu), 3 pole, current limiting type MCCB
with only SC protection for motor starter E 10072.00
b16 100 A, 50 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with only SC protection for motor starter E 10072.00
b17 125 A, 50 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with only SC protection for motor starter E 19138.00
b18 160 A, 50 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with only SC protection for motor starter E 19138.00
b19 200 A, 50 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with only SC protection for motor starter E 19142.00
b20 400 A, 50 kA (Ics=100%Icu), 3 pole, current limiting type
MCCB with only SC protection for motor starter E 26511.00
830 EARTH FAULT MODULE OF MCCB FOR EXTERNAL CT
(PERCENTAGE VA, 5P 10) WITHOUT CT

a Earth Fault Module for 100A MCCB E 5556.00


b Earth Fault Module for 125A MCCB E 5556.00
c Earth Fault Module for 160A MCCB E 5556.00
d Earth Fault Module for 200A MCCB E 5556.00
e Earth Fault Module for 250A MCCB E 6290.00
f Earth Fault Module for 400A MCCB E 6290.00
g Earth Fault Module for 630A MCCB E 5556.00

835 ACCESSORIES FOR MCCB


a Auxiliary switch (1NO + 1NC) up to 400 A E 1104.00
b Auxiliary switch (1NO + 1NC) exceeding 400 A up to 630 A
E 2020.00
c Auxiliary switch + alarm switch (1 NO + 1 NC & 1 NO) for
MCCB up to 400 A E 1711.00
d Auxiliary switch + alarm switch (1 NO + 1 NC & 1 NO) for
MCCB exceeding 400 A up to 630 A E 2356.00
e UV release for all voltage ranges up to 400 A MCCB E 2581.00
f UV release for all voltage ranges from 630 to 1600 A MCCB
E 3047.00
g Shunt release for all voltage ranges up to 400 A MCCB E 1941.00
h Shunt release for all voltage ranges from 630 to 1600 A MCCB
E 2585.00
i Rotary drive kit (including BUC handle with door inter lock
defeat & pad lock facility for MCCB up to 160 A E 1193.00
j Rotary drive kit (including BUC handle with door inter lock
defeat & pad lock facility for MCCB of rating 200 to 250 A E 1198.00
k Rotary drive kit (including BUC handle with door inter lock
defeat & pad lock facility for MCCB of rating 315 to 400 A E 1755.00
l Rotary drive kit (including BUC handle with door inter lock
defeat & pad lock facility for MCCB of rating 630 to 800 A E 1786.00
m Kastel interlock kit for MCCB of rating 250 A MCCB E 2549.00
n Kastel interlock kit for MCCB of rating from 315 to 800 A
MCCB E 2648.00
p Spreader/ terminal adapter kit Extended terminal for 3 pole
MCCB of rating up to 160 A (6 Pcs) E 551.00
q Spreader/ terminal adapter kit Extended terminal for 4 pole
MCCB of rating up to 160 A (8 Pcs)
E 656.00
r Spreader/ terminal adapter kit Extended terminal for 3 pole
MCCB of rating 200 A & 250 A (6 Pcs)
E 972.00
s Spreader/ terminal adapter kit Extended terminal for 4 pole
MCCB of rating 200 A & 250 A (8 Pcs) E 1209.00
t Spreader/ terminal adapter kit Extended terminal for 3 pole
MCCB of rating 320 A (6 Pcs)
E 1182.00
u Spreader/ terminal adapter kit Extended terminal for 4 pole
MCCB of rating 320 A (8 Pcs) E 1497.00
v Spreader/ terminal adapter kit Extended terminal for 3 pole
MCCB of rating 400 A & 630 A (6 Pcs) E 1603.00
w Spreader/ terminal adapter kit Extended terminal for 4 pole
MCCB of rating 400 A & 630 A (8 Pcs) E 2128.00

SDU & SDFU


840 S & F switch disconnector unit (isolator) complete with handle
assembly, door inter lock and padlocking arrangement of the
following ratings:

a1 32A, TP/TPN AC 23 A duty E 1132.00


a2 40 A, TP/TPN AC 23 A duty E 1162.00
a3 63 A, TP/TPN AC 23 A duty E 1612.00
a4 80 A, TP/TPN AC 23 A duty E 2044.00
a5 100 A, TP/TPN AC 23 A duty E 3302.00
a6 125 A, TP/TPN AC 23 A duty E 3830.00
a7 160 A, TP/TPN AC 23 A duty E 4448.00
a8 200 A, TP/TPN AC 23 A duty E 5758.00
a9 250 A, TP/TPN AC 23 A duty E 6651.00
a10 315 A, TP/TPN AC 23 A duty E 8142.00
a11 400 A, TP/TPN AC 23 A duty E 10969.00
a12 630 A, TP/TPN AC 23 A duty E 14604.00

b1 32 A, 4 pole AC 23 A duty E 1123.00


b2 40 A, 4 pole AC 23 A duty E 1217.00
b3 63 A, 4 pole AC 23 A duty E 1430.00
b4 80 A, 4 pole AC 23 A duty E 2092.00
b5 100 A, 4 pole AC 23 A duty E 2696.00
b6 125 A, 4 pole AC 23 A duty E 3544.00
b7 160 A, 4 pole AC 23 A duty E 4219.00
b8 200 A, 4 pole AC 23 A duty E 4640.00
b9 250 A, 4 pole AC 23 A duty E 5794.00
b10 315 A, 4 pole AC 23 A duty E 7046.00
b11 400 A, 4 pole AC 23 A duty E 9767.00
b12 630 A, 4 pole AC 23 A duty E 11192.00
Auxiliary contacts for switch disconnector unit (isolator)
c1 1 NC auxiliary contact for SDF rating of 16 - 125 A E 230.00
c2 1 NO auxiliary contact for SDF rating of 32 - 160 A E 230.00
c3 1 NC auxiliary contact for SDF rating of 160 A E 448.00
c4 1 NO auxiliary contact for SDF rating of 160A E 448.00
SDFU
841 S & F switch disconnector fuse unit complete with handle
assembly, door inter lock and padlocking arrangement of the
following ratings:
a1 32 A, AC 23 A, TPN SDF for DIN fuse E 1271.00
a2 63 A, AC 23 A, TPN SDF for DIN fuse E 1804.00
a3 80 A, AC 23 A, TPN SDF for DIN fuse E 3927.00
a4 100 A, AC 23 A, TPN SDF for DIN fuse E 3931.00
a5 125 A, AC 23 A, TPN SDF for DIN fuse E 4679.00
a6 160 A, AC 23 A, TPN SDF for DIN fuse E 5385.00
a7 200 A, AC 23 A, TPN SDF for DIN fuse E 5924.00
a8 250 A, AC 23 A, TPN SDF for DIN fuse E 7502.00
a9 315 A, AC 23 A, TPN SDF for DIN fuse E 9466.00
a10 400 A, AC 23 A, TPN SDF for DIN fuse E 11477.00
a11 500 A, AC 23 A, TPN SDF for DIN fuse E 16187.00
a12 630 A, AC 23 A, TPN SDF for DIN fuse E 17992.00

b1 32 A, AC 23 A, TPN SDF for BS fuse E 1347.00


b2 63 A, AC 23 A, TPN SDF for BS fuse E 1867.00
b3 80 A, AC 23 A, TPN SDF for BS fuse E 2299.00
b4 100 A, AC 23 A, TPN SDF for BS fuse E 3563.00
b5 125 A, AC 23 A, TPN SDF for BS fuse E 4568.00
b6 160 A, AC 23 A, TPN SDF for BS fuse E 5294.00
b7 200 A, AC 23 A, TPN SDF for BS fuse E 5882.00
b8 250 A, AC 23 A, TPN SDF for BS fuse E 7286.00
b9 315 A, AC 23 A, TPN SDF for BS fuse E 9240.00
b10 400 A, AC 23 A, TPN SDF for BS fuse E 11307.00
b11 500 A, AC 23 A, TPN SDF for BS fuse E 12073.00
b12 630 A, AC 23 A, TPN SDF for BS fuse E 17977.00
Auxiliary contacts for TPN SDFU
c1 Auxiliary contacts for TPN SDF of rating 32/ 63 A E 309.00
c2 Auxiliary contacts for TPN SDF of rating 100/ 125/ 160 A E 298.00
c3 Auxiliary contacts for TPN SDF of rating 200/ 250 A E 353.00
c4 Auxiliary contacts for TPN SDF of rating 315/ 400/ 630 A E 347.00

d1 32 A, AC 23 A, 4 pole SDF for DIN fuse E 1855.00


d2 63 A, AC 23 A, 4 pole SDF for DIN fuse E 2708.00
d3 100 A, AC 23 A, 4 pole SDF for DIN fuse E 4783.00
d4 125 A, AC 23 A, 4 pole SDF for DIN fuse E 5447.00
d5 160 A, AC 23 A, 4 pole SDF for DIN fuse E 6940.00
d6 200 A, AC 23 A, 4 pole SDF for DIN fuse E 7570.00
d7 250 A, AC 23 A, 4 pole SDF for DIN fuse E 8548.00
d8 315 A, AC 23 A, 4 pole SDF for DIN fuse E 10592.00
d9 400 A, AC 23 A, 4 pole SDF for DIN fuse E 19451.00
e1 32 A, AC 23 A, 4 pole SDF for BS fuse E 1881.00
e2 63 A, AC 23 A, 4 pole SDF for BS fuse E 2276.00
e3 100 A, AC 23 A, 4 pole SDF for BS fuse E 4415.00
e4 125 A, AC 23 A, 4 pole SDF for BS fuse E 5111.00
e5 160 A, AC 23 A, 4 pole SDF for BS fuse E 6739.00
e6 200 A, AC 23 A, 4 pole SDF for BS fuse E 7150.00
e7 250 A, AC 23 A, 4 pole SDF for BS fuse E 7859.00
e8 315 A, AC 23 A, 4 pole SDF for BS fuse E 10381.00
e9 400 A, AC 23 A, 4 pole SDF for BS fuse E 12155.00
e10 630 A, AC 23 A, 4 pole SDF for BS fuse E 20292.00
Auxiliary contacts for 4 pole SDF
f1 Auxiliary contacts (1 NO + 1 NC) for FP SDF of rating 32 - 160
A E 340.00
f2 Auxiliary contacts (2 NO + 2 NC) for FP SDF of rating 32 - 160
A E 650.00
f3 Auxiliary contacts (1 NO + 1 NC) for FP SDF of rating 200 - 800
A E 594.00
f4 Auxiliary contacts (2 NO + 2 NC) for FP SDF of rating 200 - 800
A E 1158.00
Neutral links for 4 pole SDF
g1 Neutral links for 32 - 63 A SDF/ load break switch E 144.00
g2 Neutral links for 100 - 160 A SDF/ load break switch E 164.00
g3 Neutral links for 200 - 400 A SDF/ load break switch E 276.00
g4 Neutral links for 630 - 800 A SDF/ load break switch E 291.00

842 On-load change over switch


a1 40 A, AC 23 A, 4 pole on-load COS E 3447.00
a2 63 A, AC 23 A, 4 pole on-load COS E 3523.00
a3 80 A, AC 23 A, 4 pole on-load COS E 4493.00
a4 100 A, AC 23 A, 4 pole on-load COS E 5470.00
a5 125 A, AC 23 A, 4 pole on-load COS E 6682.00
a6 160 A, AC 23 A, 4 pole on-load COS E 7240.00
a7 200 A, AC 23 A, 4 pole on-load COS E 8840.00
a8 250 A, AC 23 A, 4 pole on-load COS E 12534.00
a9 315 A, AC 23 A, 4 pole on-load COS E 13109.00
a10 400 A, AC 23 A, 4 pole on-load COS E 19010.00
a11 630 A, AC 23 A, 4 pole on-load COS E 22183.00
Auxiliary contacts for change over switches E
b1 Auxiliary contacts 1 NO + 1 NC E 204.00
b2 Auxiliary contacts 2 NO + 2 NC E 268.00
c1 32 A, AC 23 A, 4 pole on-load switch disconnector fuse change
over E 4853.00
c2 63 A, AC 23 A, 4 pole on-load switch disconnector fuse change
over E 5878.00
c3 100 A, AC 23 A, 4 pole on-load switch disconnector fuse change
E 9118.00
over
c4 125 A, AC 23 A, 4 pole on-load switch disconnector fuse change E 10571.00
c5 over
160A, AC 23 A, 4 pole on-load switch disconnector fuse change E 13647.00
c6 over
200 A, AC 23 A, 4 pole on-load switch disconnector fuse change E 17921.00
c7 over
250 A, AC 23 A, 4 pole on-load switch disconnector fuse change E 19703.00
c8 over
315 A, AC 23 A, 4 pole on-load switch disconnector fuse change E 20865.00
c9 over
400 A, AC 23 A, 4 pole on-load switch disconnector fuse change E 27817.00
c10 over
630 A, AC 23 A, 4 pole on-load switch disconnector fuse change E 39171.00
over
S & F Castel key lock
d1 Castel key lock for 100 - 250 A SDF/ LBS E 1351.00
d2 Castel key lock for 315 - 800 A SDF/ LBS E 1351.00
S & F key interlocks
e1 Key interlock (3 lock 2 keys) for 25 - 63 A SDF/ LBS E 2104.00
e2 Key interlock (3 lock 2 keys) for 100 - 250 A SDF/ LBS E 2104.00
e3 Key interlock (3 lock 2 keys) for 315 - 800 A SDF/ LBS E 2104.00

HRC fuses
S & F following HRC fuses
843 DIN type fuse links
a1 2 A, DIN type fuse link of size 000 E 221.00
a2 4 A, DIN type fuse link of size 000 E 221.00
a3 6 A, DIN type fuse link of size 000 E 209.00
a4 10 A, DIN type fuse link of size 000 E 209.00
a5 16 A, DIN type fuse link of size 000 E 209.00
a6 20 A, DIN type fuse link of size 000 E 209.00
a7 25 A, DIN type fuse link of size 000 E 209.00
a8 32 A, DIN type fuse link of size 000 E 209.00
a9 35/36 A, DIN type fuse link of size 000 E 215.00
a10 40 A, DIN type fuse link of size 000 E 215.00
a11 50 A, DIN type fuse link of size 000 E 215.00
a12 63 A, DIN type fuse link of size 000 E 215.00
a13 80 A, DIN type fuse link of size 000 E 215.00
a14 100 A, DIN type fuse link of size 000 E 215.00

b1 6 A, DIN type fuse link of size 00 E 241.00


b2 10 A, DIN type fuse link of size 00 E 241.00
b3 16 A, DIN type fuse link of size 00 E 241.00
b4 20 A, DIN type fuse link of size 00 E 241.00
b5 25 A, DIN type fuse link of size 00 E 241.00
b6 32 A, DIN type fuse link of size 00 E 241.00
b7 35/ 36 A, DIN type fuse link of size 00 E 241.00
b8 40 A, DIN type fuse link of size 00 E 241.00
b9 50 A, DIN type fuse link of size 00 E 241.00
b10 63 A, DIN type fuse link of size 00 E 241.00
b11 80 A, DIN type fuse link of size 00 E 249.00
b12 100 A, DIN type fuse link of size 00 E 249.00
b13 125 A, DIN type fuse link of size 00 E 269.00
b14 160 A, DIN type fuse link of size 00 E 269.00

c1 80 A, DIN type fuse link of size 0 E 445.00


c2 100A, DIN type fuse link of size 0 E 445.00
c3 125 A, DIN type fuse link of size 0 E 445.00
c4 160 A, DIN type fuse link of size 0 E 445.00
c5 200 A, DIN type fuse link of size 0 E 460.00

d1 50 A, DIN type fuse link of size 1 E 418.00


d2 63 A, DIN type fuse link of size 1 E 418.00
d3 80 A, DIN type fuse link of size 1 E 418.00
d4 100 A, DIN type fuse link of size 1 E 418.00
d5 125 A, DIN type fuse link of size 1 E 418.00
d6 160 A, DIN type fuse link of size 1 E 419.00
d7 200 A, DIN type fuse link of size 1 E 419.00
d8 250 A, DIN type fuse link of size 1 E 460.00
d9 315 A, DIN type fuse link of size 1 E 868.00

e1 100 A, DIN type fuse link of size 2 E 595.00


e2 125 A, DIN type fuse link of size 2 E 595.00
e3 160 A, DIN type fuse link of size 2 E 595.00
e4 200 A, DIN type fuse link of size 2 E 611.00
e5 250 A, DIN type fuse link of size 2 E 611.00
e6 315 A, DIN type fuse link of size 2 E 611.00
e7 350/355 A, DIN type fuse link of size 2 E 791.00
e8 400 A, DIN type fuse link of size 2 E 791.00

f1 315 A, DIN type fuse link of size 3 E 773.00


f2 400 A, DIN type fuse link of size 3 E 773.00
f3 425 A, DIN type fuse link of size 3 E 773.00
f4 500 A, DIN type fuse link of size 3 E 921.00
f5 630 A, DIN type fuse link of size 3 E 921.00

844 BS type fuse links


a1 2 A, clip-on offset tag fuse link of size f1 E 41.00
a2 4 A, clip-on offset tag fuse link of size f1 E 41.00
a3 6 A, clip-on offset tag fuse link of size f1 E 41.00
a4 10 A, clip-on offset tag fuse link of size f1 E 41.00
a5 16 A, clip-on offset tag fuse link of size f1 E 41.00
a6 20 A, clip-on offset tag fuse link of size f1 E 47.00
a7 25 A, clip-on offset tag fuse link of size f1 E 47.00
a8 32 A, clip-on offset tag fuse link of size f1 E 47.00

b1 2 A, bolted offset tag type fuse link of size A1 E 51.00


b2 4 A, bolted offset tag type fuse link of size A1 E 51.00
b3 6 A, bolted offset tag type fuse link of size A1 E 51.00
b4 10 A, bolted offset tag type fuse link of size A1 E 51.00
b5 16 A, bolted offset tag type fuse link of size A1 E 51.00
b6 20 A, bolted offset tag type fuse link of size A1 E 54.50
b7 25 A, bolted offset tag type fuse link of size A1 E 54.50
b8 32 A, bolted offset tag type fuse link of size A1 E 54.50

c1 20 A, bolted offset tag type fuse link of size A1L E 80.00


c2 25 A, bolted offset tag type fuse link of size A1L E 80.00
c3 32 A, bolted offset tag type fuse link of size A1L E 80.00
c4 35/36 A, bolted offset tag type fuse link of size A1L E 95.50
c5 40 A, bolted offset tag type fuse link of size A1L E 95.50
c6 50 A, bolted offset tag type fuse link of size A1L E 95.50
c7 63 A, bolted offset tag type fuse link of size A1L E 95.50
c8 80 A, bolted offset tag type fuse link of size A1L E 184.00
c9 100 A, bolted offset tag type fuse link of size A1L E 184.00
c10 125 A, bolted offset tag type fuse link of size A1L E 184.00

d1 4 A, bolted offset tag type fuse link of size A2 E 60.00


d2 6 A, bolted offset tag type fuse link of size A2 E 60.00
d3 10 A, bolted offset tag type fuse link of size A2 E 60.00
d4 16 A, bolted offset tag type fuse link of size A2 E 60.00
d5 20 A, bolted offset tag type fuse link of size A2 E 60.00
d6 25 A, bolted offset tag type fuse link of size A2 E 60.00
d7 32 A, bolted offset tag type fuse link of size A2 E 60.00

e1 32 A, bolted offset tag type fuse link of size A3 E 75.00


e2 40 A, bolted offset tag type fuse link of size A3 E 75.00
e3 35/ 36 A, bolted offset tag type fuse link of size A3 E 75.00
e4 50 A, bolted offset tag type fuse link of size A3 E 75.00
e5 63 A, bolted offset tag type fuse link of size A3 E 75.00
f1 50 A, bolted offset tag type fuse link of size A4 E 162.00
f2 63 A, bolted offset tag type fuse link of size A4 E 162.00
f3 80 A, bolted offset tag type fuse link of size A4 E 173.00
f4 100 A, bolted offset tag type fuse link of size A4 E 173.00
f5 125 A, bolted offset tag type fuse link of size A4 E 173.00
f6 160 A, bolted offset tag type fuse link of size A4 E 227.00
f7 200 A, bolted offset tag type fuse link of size A4 E 256.00

g1 50 A, bolted central tag type fuse link of size B1 E 173.00


g2 63 A, bolted central tag type fuse link of size B1 E 173.00
g3 80 A, bolted central tag type fuse link of size B1 E 179.00
g4 100 A, bolted central tag type fuse link of size B1 E 179.00
g5 125 A, bolted central tag type fuse link of size B1 E 183.00

h1 125 A, bolted central tag type fuse link of size B2 E 221.00


h2 160 A, bolted central tag type fuse link of size B2 E 234.00
h3 200 A, bolted central tag type fuse link of size B2 E 234.00
h4 250 A, bolted central tag type fuse link of size B2 E 256.00

i1 225 A, bolted central tag type fuse link of size B3 E 364.00


i2 300 A, bolted central tag type fuse link of size B3 E 364.00
i3 250 A, bolted central tag type fuse link of size B3 E 364.00
i4 315 A, bolted central tag type fuse link of size B3 E 364.00

j1 355 A, bolted central tag type fuse link of size B4 (Group A) E 550.00
j2 400 A, bolted central tag type fuse link of size B4 (Group A) E 669.00

k1 355 A, bolted central tag type fuse link of size C1 E 662.00


k2 400 A, bolted central tag type fuse link of size C1 E 662.00

l1 400 A, bolted central tag type fuse link of size C2 E 743.00


l2 450 A, bolted central tag type fuse link of size C2 E 743.00
l3 500 A, bolted central tag type fuse link of size C2 E 743.00
l4 630 A, bolted central tag type fuse link of size C2 E 1197.00

845 12 KV Fuse Links (conforming to IF 9385/IEC 282-1/BS 2692)

a1 5 ampere 12 KV Fuse links for use in air (Set of 3) set 3281.00


a2 6.3 ampere 12 KV Fuse links for use in air (Set of 3) set 3281.00
a3 10 ampere 12 KV Fuse links for use in air (Set of 3) set 3281.00
a4 16 ampere 12 KV Fuse links for use in air (Set of 3) set 3281.00
a5 20 ampere 12 KV Fuse links for use in air (Set of 3) set 3281.00
a6 25 ampere 12 KV Fuse links for use in air (Set of 3) set 3281.00
a7 31 ampere 12 KV Fuse links for use in air (Set of 3) set 3281.00
a8 36 ampere 12 KV Fuse links for use in air (Set of 3) set 3281.00
a9 40 ampere 12 KV Fuse links for use in air (Set of 3) set 3281.00
a10 45 ampere 12 KV Fuse links for use in air (Set of 3) set 3281.00
a11 50 ampere 12 KV Fuse links for use in air (Set of 3) set 3281.00
a12 56 ampere 12 KV Fuse links for use in air (Set of 3) set 3281.00
a13 63 ampere 12 KV Fuse links for use in air (Set of 3) set 3281.00
a14 71 ampere 12 KV Fuse links for use in air (Set of 3) set 3281.00
a15 80 ampere 12 KV Fuse links for use in air (Set of 3) set 3519.00

850 CONTACTORS
Power contactors for motor application
a1 9 A, 3 pole, AC 3 rated power contactor for motor application
with 1 NO + 1 NC auxiliary contacts & with AC coil
E 681.00
a2 12 A, 3 pole, AC 3 rated power contactor for motor application
with 1 NO + 1 NC auxiliary contacts & with AC coil
E 749.00
a3 17 A, 3 pole, AC 3 rated power contactor for motor application
with AC coil E 855.00
a4 26A, 3 pole, AC 3 rated power contactor for motor application
with AC coil E 1083.00
a5 32 A, 3 pole, AC 3 rated power contactor for motor application
with AC coil E 2235.00
a6 40 A, 3 pole, AC 3 rated power contactor for motor application
with AC coil E 3275.00
a7 50 A, 3 pole, AC 3 rated power contactor for motor application
with 1 NO + 1 NC auxiliary contacts & with AC coil
E 4012.00
a8 65 A, 3 pole, AC 3 rated power contactor for motor application
with 2 NO + 2 NC auxiliary contacts & with AC coil
E 5373.00
a9 75 A, 3 pole, AC 3 rated power contactor for motor application
with 2 NO + 2 NC auxiliary contacts & with AC coil
E 5899.00
a10 96 A, 3 pole, AC 3 rated power contactor for motor application
with 1 NO + 1 NC auxiliary contacts & with AC coil
E 7756.00
a11 110 A, 3 pole, AC 3 rated power contactor for motor application
with 2 NO + 2 NC auxiliary contacts & with AC coil
E 8968.00
a12 145 A, 3 pole, AC 3 rated power contactor for motor application
with 1 NO + 1 NC auxiliary contacts & with AC coil
E 11633.00
a13 185 A, 3 pole, AC 3 rated power contactor for motor application
with 1 NO+ 1 NC auxiliary contacts & with AC coil
E 15566.00
a14 210 A, 3 pole, AC 3 rated power contactor for motor application
with 2 NO + 2 NC auxiliary contacts & with AC coil
E 16537.00
a15 260 A, 3 pole, AC 3 rated power contactor for motor application
with 2 NO + 2 NC auxiliary contacts & with AC coil
E 21200.00
a16 300 A, 3 pole, AC 3 rated power contactor for motor application
with 2 NO + 2 NC auxiliary contacts & with AC coil
E 24882.00
a17 400 A, 3 pole, AC 3 rated power contactor for motor application
with 2 NO + 2 NC auxiliary contacts & with AC coil
E 30492.00
a18 460 A, 3 pole, AC 3 rated power contactor for motor application
with 1 NO+ 1 NC auxiliary contacts & with AC coil
E 43670.00
a19 580 A, 3 pole, AC 3 rated power contactor for motor application
with 1 NO+ 1 NC auxiliary contacts & with AC coil
E 57783.00

b1 9 A, 3 pole, AC 3 rated power contactor for motor application


with 1 NO + 1 NC auxiliary contacts & with DC coil
E 1035.00
b2 12 A, 3 pole, AC 3 rated power contactor for motor application
with 1 NO + 1 NC auxiliary contacts & with DC coil
E 1108.00
b3 17 A, 3 pole, AC 3 rated power contactor for motor application
with DC coil E 1220.00
b4 26A, 3 pole, AC 3 rated power contactor for motor application
with 1 NO + 1 NC auxiliary contacts & with DC coil
E 2551.00
b5 32 A, 3 pole, AC 3 rated power contactor for motor application
with DC coil E 3608.00
b6 40 A, 3 pole, AC 3 rated power contactor for motor application
with 2 NO + 2 NC auxiliary contacts & with DC coil
E 4169.00
b7 50 A, 3 pole, AC 3 rated power contactor for motor application
with DC coil E 6378.00
b8 65 A, 3 pole, AC 3 rated power contactor for motor application
with 2 NO + 2 NC auxiliary contacts & with DC coil
E 6687.00
b9 75 A, 3 pole, AC 3 rated power contactor for motor application
with 2 NO + 2 NC auxiliary contacts & with DC coil
E 7003.00
b10 96 A, 3 pole, AC 3 rated power contactor for motor application
with 2 NO + 2 NC auxiliary contacts & with DC coil
E 10197.00
b11 110 A, 3 pole, AC 3 rated power contactor for motor application
with 2 NO + 2 NC auxiliary contacts & with DC coil
E 11750.00
b12 145 A, 3 pole, AC 3 rated power contactor for motor application
with 1 NO + 1 NC auxiliary contacts & with DC coil
E 15198.00
b13 185 A, 3 pole, AC 3 rated power contactor for motor application
with 1 NO+ 1 NC auxiliary contacts & with DC coil
E 19183.00
b14 210 A, 3 pole, AC 3 rated power contactor for motor application
with 2 NO + 2 NC auxiliary contacts & with DC coil
E 24009.00
b15 260 A, 3 pole, AC 3 rated power contactor for motor application
with 2 NO + 2 NC auxiliary contacts & with DC coil
E 27290.00
b16 300 A, 3 pole, AC 3 rated power contactor for motor application
with 2 NO + 2 NC auxiliary contacts & with DC coil
E 28942.00
b17 400 A, 3 pole, AC 3 rated power contactor for motor application
with 1 NO + 1 NC auxiliary contacts & with DC coil
E 30492.00
b18 460 A, 3 pole, AC 3 rated power contactor for motor application
with 1 NO+ 1 NC auxiliary contacts & with DC coil
E 43760.00
b19 580 A, 3 pole, AC 3 rated power contactor for motor application
with 1 NO+ 1 NC auxiliary contacts & with DC coil
E 57783.00
Four pole power contactors
c1 16 A, 4 pole, AC 1 rated power contactor with AC coil E 918.00
c2 25 A, 4 pole, AC 1 rated power contactor with AC coil E 1024.00
c3 32 A, 4 pole, AC 1 rated power contactor with AC coil E 1114.00
c4 40 A, 4 pole, AC 1 rated power contactor with AC coil E 1709.00
c5 50 A, 4 pole, AC 1 rated power contactor with 1 NO + 1 NC
auxiliary contacts & with AC coil E 2013.00
c6 63 A, 4 pole, AC 1 rated power contactor with 2 NO + 2 NC
auxiliary contacts & with AC coil E 4050.00
c7 80 A, 4 pole, AC 1 rated power contactor with 2 NO + 2 NC
auxiliary contacts & with AC coil E 5468.00
c8 100 A, 4 pole, AC 1 rated power contactor with 2 NO + 2 NC
auxiliary contacts & with AC coil E 6434.00
c9 130 A, 4 pole, AC 1 rated power contactor with 1 NO + 1 NC
auxiliary contacts & with AC coil E 8921.00
c10 160 A, 4 pole, AC 1 rated power contactor with 1 NO + 1 NC
auxiliary contacts & with AC coil E 12100.00
c11 200 A, 4 pole, AC 1 rated power contactor with 1 NO + 1 NC
auxiliary contacts & with AC coil E 14786.00
c12 255 A, 4 pole, AC 1 rated power contactor with 1 NO + 1 NC
auxiliary contacts & with AC coil E 17265.00
c13 325 A, 4 pole, AC 1 rated power contactor with 2 NO + 2 NC
auxiliary contacts & with AC coil E 28292.00
c14 360 A, 4 pole, AC 1 rated power contactor with 2 NO + 2 NC
auxiliary contacts & with AC coil E 30743.00
c15 400 A, 4 pole, AC 1 rated power contactor with 2 NO + 2 NC
auxiliary contacts & with AC coil E 38081.00
c16 500 A, 4 pole, AC 1 rated power contactor with 2 NO + 2 NC
auxiliary contacts & with AC coil E 44198.00
c17 600 A, 4 pole, AC 1 rated power contactor with 2 NO + 2 NC
auxiliary contacts & with AC coil E 52757.00
c18 700 A, 4 pole, AC 1 rated power contactor with 1 NO + 1 NC
auxiliary contacts & with AC coil E 64976.00

Mini power contactors


d1 6 A, 3 pole, AC 3 rated mini power contactor with 1 NO + 1 NC
auxiliary contacts & with AC coil E 611.00
d2 9 A, 3 pole, AC 3 rated mini power contactor with 1 NO + 1 NC
auxiliary contacts & with AC coil E 783.00
d3 12 A, 3 pole, AC 3 rated mini power contactor with 1 NO + 1 NC
auxiliary contacts & with AC coil E 832.00
d4
d5 6 A, 3 pole, AC 3 rated mini power contactor with 1 NO + 1 NC
auxiliary contacts & with DC coil E 909.00
d6 9 A, 3 pole, AC 3 rated mini power contactor with 1 NO + 1 NC
auxiliary contacts & with DC coil E 947.00
d7 12 A, 3 pole, AC 3 rated mini power contactor with 1 NO + 1 NC
auxiliary contacts & with DC coil E 1014.00
e1 6 A, 4 pole, AC 3 rated mini power contactor with 1 NO + 1 NC
auxiliary contacts & with AC coil E 878.00
e2 9 A, 4 pole, AC 3 rated mini power contactor with 1 NO + 1 NC
auxiliary contacts & with AC coil E 941.00
e3
e4 6 A, 4 pole, AC 3 rated mini power contactor with 1 NO + 1 NC
auxiliary contacts & with DC coil E 878.00
e5 9 A, 4 pole, AC 3 rated mini power contactor with 1 NO + 1 NC
auxiliary contacts & with DC coil E 941.00

855 DIGITAL PROTECTIVE RELAYS


a1 3 phase over current + earth fault relay suitable for auxiliary
supply voltage of 20 - 110 V AC/DC & with 4 NO contacts E 18846.00
a2 3 phase over current + earth fault relay suitable for auxiliary
supply voltage of 20 - 110 V AC/DC & with 2 NO + 2 NC
contacts E 18846.00
a3 3 phase over current + earth fault relay suitable for auxiliary
supply voltage of 88 - 264 V AC/DC & with 4 NO contacts E 18846.00
a4 3 phase over current + earth fault relay suitable for auxiliary
supply voltage of 88 - 264 V AC/DC & with 2 NO + 2 NC
contacts E 18846.00

b1 3 phase over current + earth fault relay with high set suitable for
auxiliary supply voltage of 20 - 110 V AC/DC & with 4 NO
contacts E 25466.00
b2 3 phase over current + earth fault relay with high set suitable for
auxiliary supply voltage of 20 - 110 V AC/DC & with 2 NO + 2
NC contacts E 25466.00
b3 3 phase over current + earth fault relay with high set suitable for
auxiliary supply voltage of 88 - 264 V AC/DC & with 4 NO
contacts E 25466.00
b4 3 phase over current + earth fault relay with high set suitable for
auxiliary supply voltage of 88 - 264 V AC/DC & with 2 NO + 2
NC contacts E 25466.00

c1 3 phase over current + earth fault relay with high set & RS 485
port suitable for auxiliary supply voltage of 20 - 110 V AC/DC
E 43104.00
c2 3 phase over current + earth fault relay with high set & RS 485
port suitable for auxiliary supply voltage of 20 - 110 V AC/DC
E 43104.00
c3 3 phase over current + earth fault relay with high set & RS 485
port suitable for auxiliary supply voltage of 88 - 264 V AC/DC
E 43104.00
c4 3 phase over current + earth fault relay with high set & RS 485
port suitable for auxiliary supply voltage of 88 - 264 V AC/DC
E 43104.00

d1 Single phase over current or earth fault relay with auxiliary


supply voltage of 20 - 110 V AC/DC E 10475.00
d2 Single phase over current or earth fault relay with auxiliary
supply voltage of 88 - 264 V AC/DC E 10475.00

e1 Single phase sensitive earth fault relay with auxiliary supply


voltage of 20 - 110 V AC/DC E 10481.00
e2 Single phase sensitive earth fault relay with auxiliary supply
voltage of 88 - 264 V AC/DC E 10481.00
E
f1 Single phase under voltage or over voltage relay with auxiliary
supply voltage of 20 - 110 V AC/DC E 10481.00
f2 Single phase under voltage or over voltage relay with auxiliary
supply voltage of 88 - 264 V AC/DC E 10481.00

g1 Instantaneous earth fault relay with a range of 10% to 40% E 9146.00


g2 Instantaneous earth fault relay with a range of 20% to 80% E 9146.00

h1 Reverse power relay suitable for auxiliary supply voltage of 20 -


110 V AC/ DC E 23393.00
h2 Reverse power relay suitable for auxiliary supply voltage of 88 -
264 V AC/ DC E 23393.00

i1 Mini motor protection relay with thermal overload range of 1 -


2.75 E 8301.00
i2 Mini motor protection relay with thermal overload range of 2 -
5.5 E 8301.00
i3 Mini motor protection relay with thermal overload range of 4 - 11
E 8301.00
i4 Mini motor protection relay with thermal overload range of 8 - 22
E 8301.00
i5 Mini motor protection relay with thermal overload range of 16 -
44 E 8301.00
i6 Mini motor protection relay with thermal overload range of 32 -
88 E 8301.00
j1 Neutral displacement relay suitable for auxiliary supply voltage
of 20 - 110 V AC/ DC E 11037.00
j2 Neutral displacement relay suitable for auxiliary supply voltage
of 88 - 264 V AC/ DC E 11037.00

856 Control & supervisory relays


a PT fuse failure relay E 9146.00
b Trip circuit supervision relay 20 - 110 V AC/ DC E 10258.00
c Trip circuit supervision relay 88 - 264 V AC/ DC E 10258.00

857 Other relays


a1 Feeder manager 20 - 110 V E 264546.00
a2 Feeder manager 88 - 264 V E 264546.00
b1 Frequency relay 20 - 110 V E 132281.00
b2 Frequency relay 88 - 264 V E 132281.00
c1 Motor protection relay 20 - 110 V E 72766.00
c2 Motor protection relay 88 - 264 V E 72766.00
c3 Motor protection relay with voltage input 20 - 110 V E 90402.00
c4 Motor protection relay with voltage input 88 - 264 V E 90402.00
d1 Generator protection relay for generators with NGR neutral
grounding resistor) 20 - 110 V E 231464.00
d2 Generator protection relay for generators with NGR neutral
grounding resistor) 88 - 264 V E 231458.00
d3 Generator protection relay for generators without NGR neutral
grounding resistor) 20 - 110 V E 231477.00
d4 Generator protection relay for generators without NGR neutral
grounding resistor) 88 - 264 V E 231477.00
e1 Differential relay for generators 20 - 110 V E 286582.00
e2 Differential relay for generators 88 - 264 V E 286582.00
e3 Differential relay for transformers 20 - 110 V E 159838.00
e4 Differential relay for transformers 88 - 264 V E 159838.00
f1 3 PH O/C & E/F relay for transformers 20 - 110 V E 132286.00
f2 3 PH O/C & E/F relay for transformers 88 - 264 V E 132286.00
g1 Frequency & 1 ph voltage relay 20 – 110 V, in the existing panel
assembly. E 77180.00
g2 Frequency & 1 ph voltage relay 88 – 264 V, in the existing panel
assembly. E 77180.00
g3 Frequency & 3 ph voltage relay 20 – 110 V, in the existing panel
assembly. E 103630.00
g4 Frequency & 3 ph voltage relay 88 – 264 V, in the existing panel
assembly. E 103630.00
h1 2 O/C + E/F relay 20 – 110 V, in the existing panel assembly.
E 83792.00
h2 2 O/C + E/F relay 88 – 264 V, in the existing panel assembly.
E 83792.00
h3 3 O/C + E/F relay 20 – 110 V, in the existing panel assembly.
E 89854.00
h4 3 O/C + E/F relay 88 – 264 V, in the existing panel assembly.
E 89854.00
i1 Auto synchronising relay 20 - 110 V E 154328.00
i2 Auto synchronising relay 88 - 264 V E 154328.00
j1 U/V relay with neutral monitoring 20 - 110 V E 132286.00
j2 U/V relay with neutral monitoring 88 - 264 V E 132286.00
k1 Power management relay 20 - 110 V E 176352.00
k2 Power management relay 88 - 264 V E 176352.00
l1 Load sharing relay 20 - 110 V E 99232.00
l2 Load sharing relay 88 - 264 V E 99232.00
PANEL MOUNTING METERS - ANALOGUE TYPE
860 Analogue type voltmeters
a1 0 - 250 V analogue type AC volt meter with 90° deflection scale,
accuracy class 1 & of size 72 x 72 mm E 439.00
a2 0 - 300 V analogue type AC volt meter with 90° deflection scale,
accuracy class 1 & of size 72 x 72 mm E 439.00
a3 0 - 400 V analogue type AC volt meter with 90° deflection scale,
accuracy class 1 & of size 72 x 72 mm E 497.00
a4 0 - 500 V analogue type AC volt meter with 90° deflection scale,
accuracy class 1 & of size 72 x 72 mm E 497.00
a5 0 - 600 V analogue type AC volt meter with 90° deflection scale,
accuracy class 1 & of size 72 x 72 mm E 497.00
a6 Analogue type AC volt meter with 90° deflection scale, accuracy
class 1 & of size 72 x 72 mm suitable for 0-15 KV, PT 11
KV/110 V E 439.00

b1 0 - 250 V analogue type AC volt meter with 90° deflection scale,


accuracy class 1 & of size 96 x 96 mm E 508.00
b2 0 - 300 V analogue type AC volt meter with 90° deflection scale,
accuracy class 1 & of size 96 x 96 mm E 508.00
b3 0 - 400 V analogue type AC volt meter with 90° deflection scale,
accuracy class 1 & of size 96 x 96 mm E 529.00
b4 0 - 500 V analogue type AC volt meter with 90° deflection scale,
accuracy class 1 & of size 96 x 96 mm E 529.00
b5 0 - 600 V analogue type AC volt meter with 90° deflection scale,
accuracy class 1 & of size 96 x 96 mm E 529.00
b6 Analogue type AC volt meter with 90° deflection scale, accuracy
class 1 & of size 96 x 96 mm suitable for 0-15 KV, PT 11
KV/110 V E 509.00
c1 0 - 250 V analogue type AC volt meter with 90° deflection scale,
accuracy class 1 & of size 144 x 144 mm E 772.00
c2 0 - 300 V analogue type AC volt meter with 90° deflection scale,
accuracy class 1 & of size 144 x 144 mm E 772.00
c3 0 - 400 V analogue type AC volt meter with 90° deflection scale,
accuracy class 1 & of size 144 x 144 mm E 531.00
c4 0 - 500 V analogue type AC volt meter with 90° deflection scale,
accuracy class 1 & of size 144 x 144 mm E 531.00
c5 0 - 600 V analogue type AC volt meter with 90° deflection scale,
accuracy class 1 & of size 144 x 144 mm E 531.00
c6 Analogue type AC volt meter with 90° deflection scale, accuracy
class 1 & of size 144 x 144 mm suitable for 0-15 KV, PT 11
KV/110 V E 722.00

Analogue type ammeters


d1 0 - 100 mA, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 72 x 72 mm E 459.00
d2 0 - 150 mA, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 72 x 72 mm E 459.00
d3 0 - 250 mA, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 72 x 72 mm E 459.00
d4 0 - 400 mA, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 72 x 72 mm E 459.00
d5 0 - 600 mA, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 72 x 72 mm E 459.00
d6 0 - 1 A, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 72 x 72 mm E 459.00
d7 0 - 1.5 A, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 72 x 72 mm E 459.00
d8 0 - 2.5 A, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 72 x 72 mm E 459.00
d9 0 - 3 A, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 72 x 72 mm E 459.00
d10 0 - 4 A, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 72 x 72 mm E 459.00
d11 0 - 5 A, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 72 x 72 mm E 459.00
d12 0 - 40 A, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 72 x 72 mm E 532.00
d13 0 - 50 A, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 72 x 72 mm E 532.00
d14 0 - 60 A, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 72 x 72 mm E 532.00
d15 0 - 75 A, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 72 x 72 mm E 532.00
d16 0 - 100 A, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 72 x 72 mm E 532.00

e1 0 - 100 mA, direct reading, analogue type AC ammeter with 90°


deflection scale, accuracy class 1 & of size 96 x 96 mm E 644.00
e2 0 - 150 mA, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 96 x 96 mm E 644.00
e3 0 - 250 mA, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 96 x 96 mm E 644.00
e4 0 - 400 mA, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 96 x 96 mm E 644.00
e5 0 - 600 mA, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 96 x 96 mm E 644.00
e6 0 - 1 A, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 96 x 96 mm E 644.00
e7 0 - 1.5 A, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 96 x 96 mm E 644.00
e8 0 - 2.5 A, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 96 x 96 mm E 644.00
e9 0 - 3 A, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 96 x 96 mm E 644.00
e10 0 - 4 A, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 96 x 96 mm E 644.00
e11 0 - 5 A, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 96 x 96 mm E 644.00
e12 0 - 10 A, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 96 x 96 mm E 644.00
e13 0 - 20 A, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 96 x 96 mm E 644.00
e14 0 - 25 A, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 96 x 96 mm E 644.00
e15 0 - 30 A, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 96 x 96 mm E 644.00
e16 0 - 40 A, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 96 x 96 mm E 754.00
e17 0 - 50 A, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 96 x 96 mm E 754.00
e18 0 - 75 A, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 96 x 96 mm E 754.00
e19 0 - 100 A, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 96 x 96 mm E 754.00

f1 0 - 100 mA, direct reading, analogue type AC ammeter with 90°


deflection scale, accuracy class 1 & of size 144 x 144 mm
E 409.00
f2 0 - 150 mA, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 144 x 144 mm
E 409.00
f3 0 - 250 mA, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 144 x 144 mm
E 409.00
f4 0 - 400 mA, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 144 x 144 mm
E 409.00
f5 0 - 600 mA, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 144 x 144 mm
E 409.00
f6 0 - 1 A, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 144 x 144 mm E 409.00
f7 0 - 1.5 A, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 144 x 144 mm
E 409.00
f8 0 - 2.5 A, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 144 x 144 mm
E 409.00
f9 0 - 3 A, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 144 x 144 mm E 409.00
f10 0 - 4 A, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 144 x 144 mm E 409.00
f11 0 - 5 A, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 144 x 144 mm E 409.00
f12 0 - 56A, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 144 x 144 mm
E 409.00
f13 0 - 10 A, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 144 x 144 mm
E 409.00
f14 0 - 20 A, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 144 x 144 mm
E 409.00
f15 0 - 25 A, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 144 x 144 mm
E 409.00
f16 0 - 30 A, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 144 x 144 mm
E 409.00
f17 0 - 40 A, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 144 x 144 mm
E 510.00
f18 0 - 50 A, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 144 x 144 mm
E 510.00
f19 0 - 75 A, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 144 x 144 mm
E 510.00
f20 0 - 100 A, direct reading, analogue type AC ammeter with 90°
deflection scale, accuracy class 1 & of size 144 x 144 mm
E 510.00
AC ammeters - CT operated type
g1 CT operated, analogue type AC ammeter with 90° deflection
scale, suitable dial, accuracy class 1 & of size 72 x 72 mm
E 409.00
g2 CT operated, analogue type AC ammeter with 90° deflection
scale, suitable dial, accuracy class 1 & of size 96 x 96 mm
E 459.00
g3 CT operated, analogue type AC ammeter with 90° deflection
scale, suitable dial, accuracy class 1 & of size 144 x 144 mm
E 645.00
g4 CT operated, analogue type AC ammeter with 240° deflection
scale, suitable dial, accuracy class 1 & of size 72 x 72 mm
E 1267.00
g5 CT operated, analogue type AC ammeter with 240° deflection
scale, suitable dial, accuracy class 1 & of size 96 x 96 mm
E 1335.00
g6 CT operated, analogue type AC ammeter with 240° deflection
scale, suitable dial, accuracy class 1 & of size 144 x 144 mm
E 1545.00

h1 CT operated, analogue, bi metal type AC maximum demand


ammeter with 90° deflection scale, suitable dial, accuracy class 1
& of size 96 x 96 mm E 1508.00
Frequency meters
i1 45-50-55 Hz, analogue type frequency meter with 90° deflection
scale of all voltage ranges, accuracy class 1 & of size 96 x 96 mm
E 936.00
i2 48-50-52 Hz, analogue type frequency meter with 90° deflection
scale of all voltage ranges, accuracy class 1 & of size 96 x 96 mm
E 936.00
i3 45-50-55 Hz, analogue type frequency meter with 90° deflection
scale of all voltage ranges, accuracy class 1 & of size 144 x 144
mm E 1024.00
i4 48-50-52 Hz, analogue type frequency meter with 90° deflection
scale of all voltage ranges, accuracy class 1 & of size 144 x 144
mm E 1024.00

j1 45-50-55 Hz, vibrating reed type frequency meter for all voltage
ranges, accuracy class 1 & of size 96 x 96 mm E 730.00
Power factor meters
k1 Analogue type power factor meters of range 0.50-1-0.50 for
balanced/ unbalanced load with 90° deflection scale of all voltage
ranges, 1 A/ 5 A rated, 1 element type suitable for single/ three
phase application, accuracy class 1 & of size 96 x 96 mm

E 1596.00
k2 Analogue type power factor meters of range 0.80-1-0.80 for
balanced/ unbalanced load with 90° deflection scale of all voltage
ranges, 1 A/ 5 A rated, 1 element type suitable for single/ three
phase application, accuracy class 1 & of size 96 x 96 mm

E 1596.00
k3 Analogue type power factor meters of range 0.50-1-0.50 for
balanced/ unbalanced load with 90° deflection scale of all voltage
ranges, 1 A/ 5 A rated, 2 element type suitable for three phase
application, accuracy class 1 & of size 96 x 96 mm

E 3520.00
k4 Analogue type power factor meters of range 0.50-1-0.50 for
balanced/ unbalanced load with 90° deflection scale of all voltage
ranges, 1 A/ 5 A rated, 3 element type suitable for three phase
application, accuracy class 1 & of size 96 x 96 mm

E 4314.00
k5 Analogue type power factor meters of range 0.50-1-0.50 for
balanced/ unbalanced load with 90° deflection scale of all voltage
ranges, 1 A/ 5 A rated, 1 element type suitable for single/ three
phase application, accuracy class 1 & of size 144 x 144 mm

E 1684.00
k6 Analogue type power factor meters of range 0.80-1-0.80 for
balanced/ unbalanced load with 90° deflection scale of all voltage
ranges, 1 A/ 5 A rated, 1 element type suitable for single/ three
phase application, accuracy class 1 & of size 144 x 144 mm

E 1684.00
k7 Analogue type power factor meters of range 0.50-1-0.50 for
balanced/ unbalanced load with 90° deflection scale of all voltage
ranges, 1 A/ 5 A rated, 2 element type suitable for three phase
application, accuracy class 1 & of size 144 x 144 mm

E 3962.00
k8 Analogue type power factor meters of range 0.50-1-0.50 for
balanced/ unbalanced load with 90° deflection scale of all voltage
ranges, 1 A/ 5 A rated, 3 element type suitable for three phase
application, accuracy class 1 & of size 144 x 144 mm

E 4839.00

Power (KW) meters


l1 Analogue type CT operated power (KW) meters with 90°
deflection scale of all voltage ranges, 1 A/ 5 A rated, 1 element
type suitable for single phase application, accuracy class 1 & of
size 96 x 96 mm
E 1773.00
l2 Analogue type CT operated power (KW) meters with 90°
deflection scale of all voltage ranges, 1 A/ 5 A rated, 1 element
type suitable for three phase application, accuracy class 1 & of
size 96 x 96 mm
E 2120.00
l3 Analogue type CT operated power (KW) meters with 90°
deflection scale of all voltage ranges, 1 A/ 5 A rated, 2 element
type suitable for three phase application, accuracy class 1 & of
size 96 x 96 mm
E 2822.00
l4 Analogue type CT operated power (KW) meters with 90°
deflection scale of all voltage ranges, 1 A/ 5 A rated, 3 element
type suitable for three phase application, accuracy class 1 & of
size 96 x 96 mm
E 3520.00
l5 Analogue type CT operated power (KW) meters with 90°
deflection scale of all voltage ranges, 1 A/ 5 A rated, 1 element
type suitable for single phase application, accuracy class 1 & of
size 144 x 144 mm
E 1978.00
l6 Analogue type CT operated power (KW) meters with 90°
deflection scale of all voltage ranges, 1 A/ 5 A rated, 1 element
type suitable for three phase application, accuracy class 1 & of
size 144 x 144 mm
E 2266.00
l7 Analogue type CT operated power (KW) meters with 90°
deflection scale of all voltage ranges, 1 A/ 5 A rated, 2 element
type suitable for three phase application, accuracy class 1 & of
size 144 x 144 mm
E 3151.00
l8 Analogue type CT operated power (KW) meters with 90°
deflection scale of all voltage ranges, 1 A/ 5 A rated, 3 element
type suitable for three phase application, accuracy class 1 & of
size 144 x 144 mm
E 3916.00

Power (KVAR) meters


m1 Analogue type CT operated power (KVAR) meters with 240°
deflection scale of all voltage ranges, 1 A/ 5 A rated, 1 element
type suitable for single phase application, accuracy class 1 & of
size 96 x 96 mm
E 1773.00
m2 Analogue type CT operated power (KVAR) meters with 240°
deflection scale of all voltage ranges, 1 A/ 5 A rated, 2 element
type suitable for three phase application, accuracy class 1 & of
size 96 x 96 mm
E 2701.00
m3 Analogue type CT operated power (KVAR) meters with 240°
deflection scale of all voltage ranges, 1 A/ 5 A rated, 3 element
type suitable for three phase application, accuracy class 1 & of
size 96 x 96 mm
E 3520.00
m4 Analogue type CT operated power (KVAR) meters with 240°
deflection scale of all voltage ranges, 1 A/ 5 A rated, 1 element
type suitable for single phase application, accuracy class 1 & of
size 144 x 144 mm
E 1978.00
m5 Analogue type CT operated power (KVAR) meters with 240°
deflection scale of all voltage ranges, 1 A/ 5 A rated, 2 element
type suitable for three phase application, accuracy class 1 & of
size 144 x 144 mm
E 3151.00
m6 Analogue type CT operated power (KVAR) meters with 240°
deflection scale of all voltage ranges, 1 A/ 5 A rated, 3 element
type suitable for three phase application, accuracy class 1 & of
size 144 x 144 mm
E 3916.00

n1 LED type synchroscope of size 96 x 96 mm suitable for 110/ 240/


440 V E 2384.00
PANEL MOUNTING METERS - DIGITAL TYPE
861 Single phase meters
a1 Single phase voltmeter of accuracy class 1 E 1535.00
a2 Single phase kilo voltmeter of accuracy class 1 E 1535.00
a3 Single phase ammeter of accuracy class 1 E 1535.00
a4 Single phase frequency of accuracy class 1 E 1535.00
a5 Single phase voltmeter of accuracy class 0.50 E 2071.00
a6 Single phase kilo voltmeter of accuracy class 0.50 E 2071.00
a7 Single phase ammeter of accuracy class 0.50 E 2071.00
a8 Single phase frequency of accuracy class 0.50 E 2071.00
Three phase meters
b1 Three phase volt meter (V - RY, YB, BR, R, Y, B) of accuracy E 2519.00
b2 class
Three1 phase kilo volt meter (V - RY, YB, BR, R, Y, B) of
accuracy class 1 E 2519.00
b3 Three phase ammeter (A - R, Y, B) of accuracy class 1 E 2768.00
b4 Three phase energy meter (A - R, Y, B) of accuracy class 1
E 4928.00
b5 Three phase volt meter (V - RY, YB, BR, R, Y, B) of accuracy
class 0.50 E 3232.00
b6 Three phase kilo volt meter (V - RY, YB, BR, R, Y, B) of
accuracy class 0.50 E 3232.00
b7 Three phase ammeter (A - R, Y, B) of accuracy class 0.50 E 3481.00
b8 Three phase energy meter (A - R, Y, B) of accuracy class 0.50
E 5909.00
Multifunction meters
c1 Three phase multifunction meters to read V, A and F, accuracy E 2695.00
c2 class
Three1phase multifunction meters to read W, Wh or VA, VAh or
VAR, VARh or pf, accuracy class 1. E 5372.00
c3 Three phase multifunction meters to read W, Wh , pf or VA or
VAR, VARh accuracy class 1. E 6266.00
c4 Three phase multifunction meters to read V, A and F, accuracy
class 0.5 E 3367.00
c5 Three phase multifunction meters to read W, Wh or VA, VAh or
VAR, VARh or pf, accuracy class 0.5 E 6711.00
c6 Three phase multifunction meters to read W, Wh , pf or VA or
VAR, VARh accuracy class 0.5. E 7831.00
Monitors and Demand Controllers
d1 Power and Energy monitor without port of accuracy class 1. E 25980.00
d2 Power and Energy monitor with port of accuracy class 1. E 32471.00
d3 Trivector monitor without port of accuracy class 1. E 42295.00
d4 Trivector monitor with port of accuracy class 1. E 48336.00
d5 Smart Demand Controller without port of accuracy class 1. E 55462.00
d6 Smart Demand Controller with port of accuracy class 1. E 61415.00
d7 Power and Energy monitor without port of accuracy class 0.5.
E 29010.00
d8 Power and Energy monitor with port of accuracy class 0.5. E 35653.00
d9 Trivector monitor without port of accuracy class 0.5. E 45516.00
d10 Trivector monitor with port of accuracy class 0.5. E 52162.00
d11 Smart Demand Controller without port of accuracy class 0.5.
E 58684.00
d12 Smart Demand Controller with port of accuracy class 0.5. E 65330.00
Load Managers
e1 Load manager of accuracy class 1.0 E 15192.00
e2 Load manager with RS 485 of accuracy class 1.0 E 22277.00
e3 Load manager with demand of accuracy class 1.0 E 23109.00
e4 Load manager with demand & RS 485 of accuracy class 1.0 E 30214.00
e5 Load manager with I/E option of accuracy class 1.0 E 22220.00
e6 Load manager with I/E option & RS 485 of accuracy class 1.0
E 29325.00
e7 Load manager with I/E option & demand of accuracy class 1.0
E 26659.00
e8 Load manager with I/E option, demand & RS 485 of accuracy E 33764.00
e9 class
Power1.0
and energy monitor with RS 485 of accuracy class 1.0
E 12454.00
Multifunction meters
f1 V, A, F, PF meter of accuracy class 1.0 E 4458.00
f2 V, A, F, PF meter with RS 485 of accuracy class 1.0 E 6076.00
f3 Energy meter of accuracy class 1.0 E 15078.00
f4 Energy meter with RS 485 of accuracy class 1.0 E 22167.00
f5 Load manager of accuracy class 0.5 E 17778.00
f6 Load manager with RS 485 of accuracy class 0.5 E 24836.00
f7 Load manager with demand of accuracy class 0.5 E 25532.00
f8 Load manager with demand & RS 485 of accuracy class 0.5 E 32637.00
f9 Load manager with I/E option of accuracy class 0.5 E 24644.00
f10 Load manager with I/E option & RS 485 of accuracy class 0.5
E 31749.00
f11 Load manager with I/E option & demand of accuracy class 0.5
E 29083.00
f12 Load manager with I/E option, demand & RS 485 of accuracy E 36187.00
f13 class
Power0.5
and energy monitor with RS 485 of accuracy class 0.5
E 15115.00
f14 V, A, F, PF meter of accuracy class 0.5 E 6863.00
f15 V, A, F, PF meter with RS 485 of accuracy class 0.5 E 8477.00
f16 Energy meter of accuracy class 0.5 E 7266.00
f17 Energy meter with RS 485 of accuracy class 0.5 E 8074.00

862 SURFACE MOUNTING METERS


TOD Meter
a1 3 phase, 3 wire, 110 V ( L-L), -/1 A CT or -/5A CT of class 1.
E 17267.00
a2 3 phase, 3 wire, 110 V ( L-L), -/1 A CT or -/5A CT of class 0.5.
E 22339.00
Base mount electronic type energy meter
b1 10 - 40 A, 240 V single phase KWh meter of accuracy class 1
E 2435.00
b2 10 - 60 A, 240 V single phase KWh meter of accuracy class 1
E 3083.00
b3 1 - 2 A/ 5 - 10 A, CT operated, 3 phase 3 wire KWh meter of
accuracy class 1. E 6313.00
b4 1 - 2 A CT operated, 3 phase 4 wire KWh meter of accuracy class
1. E 6313.00
b5 5 - 10 A CT operated, 3 phase 4 wire KWh meter of accuracy E 5667.00
b6 class
5 - 101.A direct reading, 3 phase 4 wire KWh meter of accuracy E 5668.00
b7 class
10 1 A direct reading, 3 phase 4 wire KWh meter of accuracy E
- 40 5668.00
b8 class
50 1 A direct reading, 3 phase 4 wire KWh meter of accuracy E
- 100 8090.00
b9 class
10 - 401 A, 240 V single phase KWh meter of accuracy class 0.5
E 1344.00
b10 10 - 60 A, 240 V single phase KWh meter of accuracy class 0.5
E 1344.00
b11 1 - 2 A/ 5 - 10 A, CT operated, 3 phase 3 wire KWh meter of
accuracy class 0.5 E 3526.00
b12 1 - 2 A CT operated, 3 phase 4 wire KWh meter of accuracy class E 3526.00
b13 0.5
5 - 10 A CT operated, 3 phase 4 wire KWh meter of accuracy E 3526.00
b14 class
5 - 100.5
A direct reading, 3 phase 4 wire KWh meter of accuracy
class 0.5 E 3648.00
b15 10 - 40 A direct reading, 3 phase 4 wire KWh meter of accuracy
class 0.5 E 3648.00
Flush mount Electronic type Energy meters - 96 x 96 mm.

c1 3 phase 4 wire 110/ 240/ 415 V, -/1 A, flush mount electronic


energy meter of size 96 x 96 mm. and of accuracy class 1.
E 6879.00
c2 3 phase 4 wire 110/ 240/ 415 V, -/5 A, flush mount electronic
energy meter of size 96 x 96 mm. and of accuracy class 1.
E 6475.00
Selector Switches E
d1 6 A 3 pole ammeter selector switch. E 146.00
d2 6 A 3 pole voltmeter selector switch to read voltage between 3 E 118.00
d3 phases.
6 A 3 pole voltmeter selector switch to read voltage between 3
phases and neutral. E 118.00
d4 6 A 3 pole voltmeter selector switch to read voltage between 3
phases and 3 phase and neutral. E 192.00
870 CURRENT TRANSFORMER
Tape wound metering CT
a1 20/ 5 A, 30/ 5 A, 40/ 5 A, 5 VA, tape wound metering CT of
accuracy class 5. E 537.00
a2 50/ 5 A to 75/ 5 A, 5 VA, tape wound metering CT of accuracy
class 3. E 554.00
a3 100/ 5 A, 5 VA, tape wound metering CT of accuracy class 1.
E 621.00
a4 100/ 5 A, 5 VA, tape wound metering CT of accuracy class 0.5
E 1336.00
a5 120/ 5 A, 5 VA, tape wound metering CT of accuracy class 1.
E 647.00
a6 120/ 5 A, 5 VA, tape wound metering CT of accuracy class 0.5
E 1235.00
a7 150/ 5 A, 5 VA, tape wound metering CT of accuracy class 1.
E 848.00
a8 150/ 5 A, 5 VA, tape wound metering CT of accuracy class 0.5
E 897.00
a9 200/ 5 A, 5 VA, tape wound metering CT of accuracy class 1.
E 729.00
a10 200/ 5 A, 5 VA, tape wound metering CT of accuracy class 0.5
E 848.00
a11 250/ 5 A, 5 VA, tape wound metering CT of accuracy class 1.
E 766.00
a12 250/ 5 A, 5 VA, tape wound metering CT of accuracy class 0.5
E 865.00
a13 300/ 5 A, 5 VA, tape wound metering CT of accuracy class 1.
E 729.00
a14 300/ 5 A, 5 VA, tape wound metering CT of accuracy class 0.5
E 874.00
a15 400/ 5 A, 5 VA, tape wound metering CT of accuracy class 1.
E 697.00
a16 400/ 5 A, 5 VA, tape wound metering CT of accuracy class 0.5
E 848.00
a17 200/ 5 A, 10 VA, tape wound metering CT of accuracy class 1.
E 781.00
a18 200/ 5 A, 10 VA, tape wound metering CT of accuracy class 0.5
E 1017.00
a19 250/ 5 A, 10 VA, tape wound metering CT of accuracy class 1.
E 915.00
a20 250/ 5 A, 10 VA, tape wound metering CT of accuracy class 0.5
E 1007.00
a21 300/ 5 A, 10 VA, tape wound metering CT of accuracy class 1.
E 932.00
a22 300/ 5 A, 10 VA, tape wound metering CT of accuracy class 0.5
E 966.00
a23 400/ 5 A, 10 VA, tape wound metering CT of accuracy class 1.
E 781.00
a24 400/ 5 A, 10 VA, tape wound metering CT of accuracy class 0.5
E 949.00
a25 400/ 5 A, 15 VA, tape wound metering CT of accuracy class 1.
E 881.00
a26 400/ 5 A, 15 VA, tape wound metering CT of accuracy class 0.5
E 1017.00
a27 500/ 5 A, 15 VA, tape wound metering CT of accuracy class 1.
E 941.00
a28 500/ 5 A, 15 VA, tape wound metering CT of accuracy class 0.5
E 1059.00
a29 600/ 5 A, 15 VA, tape wound metering CT of accuracy class 1.
E 1017.00
a30 600/ 5 A, 15 VA, tape wound metering CT of accuracy class 0.5
E 1118.00
a31 800/ 5 A, 15 VA, tape wound metering CT of accuracy class 1.
E 1092.00
a32 800/ 5 A, 15 VA, tape wound metering CT of accuracy class 0.5
E 1185.00
a33 1000/ 5 A, 15 VA, tape wound metering CT of accuracy class 1.
E 1159.00
a34 1000/ 5 A, 15 VA, tape wound metering CT of accuracy class 0.5
E 1269.00
a35 1200/ 5 A, 15 VA, tape wound metering CT of accuracy class 1.
E 1201.00
a36 1200/ 5 A, 15 VA, tape wound metering CT of accuracy class 0.5
E 1286.00
a37 1500/ 5 A, 15 VA, tape wound metering CT of accuracy class 1.
E 1319.00
a38 1500/ 5 A, 15 VA, tape wound metering CT of accuracy class 0.5
E 1403.00
a39 1600/ 5 A, 15 VA, tape wound metering CT of accuracy class 1.
E 1353.00
a40 1600/ 5 A, 15 VA, tape wound metering CT of accuracy class 0.5
E 1437.00
a41 2000/ 5 A, 15 VA, tape wound metering CT of accuracy class 1.
E 1673.00
a42 2000/ 5 A, 15 VA, tape wound metering CT of accuracy class 0.5
E 1739.00
Resin cast metering CT
b1 20/ 5 A, 30/ 5 A, 40/ 5 A, 5 VA, resin cast metering CT of
accuracy class 5. E 966.00
b2 50/ 5 A to 75/ 5 A, 5 VA, resin cast metering CT of accuracy E 999.00
b3 class
100/ 53.A, 5 VA, resin cast metering CT of accuracy class 1. E 1134.00
b4 100/ 5 A, 5 VA, resin cast metering CT of accuracy class 0.5
E 1269.00
b5 120/ 5 A, 5 VA, resin cast metering CT of accuracy class 1. E 983.00
b6 120/ 5 A, 5 VA, resin cast metering CT of accuracy class 0.5
E 1118.00
b7 150/ 5 A, 5 VA, resin cast metering CT of accuracy class 1. E 881.00
b8 150/ 5 A, 5 VA, resin cast metering CT of accuracy class 0.5
E 941.00
b9 200/ 5 A, 5 VA, resin cast metering CT of accuracy class 1. E 999.00
b10 200/ 5 A, 5 VA, resin cast metering CT of accuracy class 0.5
E 1067.00
b11 250/ 5 A, 5 VA, resin cast metering CT of accuracy class 1. E 999.00
b12 250/ 5 A, 5 VA, resin cast metering CT of accuracy class 0.5
E 1118.00
b13 300/ 5 A, 5 VA, resin cast metering CT of accuracy class 1. E 966.00
b14 300/ 5 A, 5 VA, resin cast metering CT of accuracy class 0.5
E 1101.00
b15 400/ 5 A, 5 VA, resin cast metering CT of accuracy class 1. E 983.00
b16 400/ 5 A, 5 VA, resin cast metering CT of accuracy class 0.5
E 1067.00
b17 200/ 5 A, 10 VA, resin cast metering CT of accuracy class 1.
E 1185.00
b18 200/ 5 A, 10 VA, resin cast metering CT of accuracy class 0.5
E 1269.00
b19 250/ 5 A, 10 VA, resin cast metering CT of accuracy class 1.
E 1185.00
b20 250/ 5 A, 10 VA, resin cast metering CT of accuracy class 0.5
E 1269.00
b21 300/ 5 A, 10 VA, resin cast metering CT of accuracy class 1.
E 1118.00
b22 300/ 5 A, 10 VA, resin cast metering CT of accuracy class 0.5
E 1201.00
b23 400/ 5 A, 10 VA, resin cast metering CT of accuracy class 1.
E 1151.00
b24 400/ 5 A, 10 VA, resin cast metering CT of accuracy class 0.5
E 1243.00
b25 400/ 5 A, 15 VA, resin cast metering CT of accuracy class 1.
E 1167.00
b26 400/ 5 A, 15 VA, resin cast metering CT of accuracy class 0.5
E 1269.00
b27 500/ 5 A, 15 VA, resin cast metering CT of accuracy class 1.
E 1151.00
b28 500/ 5 A, 15 VA, resin cast metering CT of accuracy class 0.5
E 1235.00
b29 600/ 5 A, 15 VA, resin cast metering CT of accuracy class 1.
E 1201.00
b30 600/ 5 A, 15 VA, resin cast metering CT of accuracy class 0.5
E 1251.00
b31 800/ 5 A, 15 VA, resin cast metering CT of accuracy class 1.
E 1167.00
b32 800/ 5 A, 15 VA, resin cast metering CT of accuracy class 0.5
E 1217.00
b33 1000/ 5 A, 15 VA, resin cast metering CT of accuracy class 1.
E 1251.00
b34 1000/ 5 A, 15 VA, resin cast metering CT of accuracy class 0.5
E 1303.00
b35 1200/ 5 A, 15 VA, resin cast metering CT of accuracy class 1.
E 1303.00
b36 1200/ 5 A, 15 VA, resin cast metering CT of accuracy class 0.5
E 1353.00
b37 1500/ 5 A, 15 VA, resin cast metering CT of accuracy class 1.
E 1471.00
b38 1500/ 5 A, 15 VA, resin cast metering CT of accuracy class 0.5
E 1530.00
b39 1600/ 5 A, 15 VA, resin cast metering CT of accuracy class 1.
E 1521.00
b40 1600/ 5 A, 15 VA, resin cast metering CT of accuracy class 0.5
E 1571.00
b41 2000/ 5 A, 15 VA, resin cast metering CT of accuracy class 1.
E 1723.00
b42 2000/ 5 A, 15 VA, resin cast metering CT of accuracy class 0.5
E 1774.00
Tape wound protection CT
c1 100/ 5 A, 5 VA, 10 P 5, tape wound protection CT E 1369.00
c2 100/ 5 A, 10 VA, 10 P 5, tape wound protection CT E 2312.00
c3 150/ 5 A, 7.5 VA, 10 P 5, tape wound protection CT E 1403.00
c4 150/ 5 A, 7.5 VA, 10 P 10, tape wound protection CT E 3025.00
c5 200/ 5 A, 10 VA, 10 P 10, tape wound protection CT E 2731.00
c6 200/ 5 A, 10 VA, 10 P 5, tape wound protection CT E 1698.00
c7 300/ 5 A, 10 VA, 10 P 10, tape wound protection CT E 1613.00
c8 300/ 5 A, 10 VA, 10 P 5, tape wound protection CT E 3346.00
c9 400/ 5 A, 10 VA, 10 P 10, tape wound protection CT E 2105.00
c10 400/ 5 A, 10 VA, 10 P 5, tape wound protection CT E 1802.00
c11 500/ 5 A, 15 VA, 10 P 10, tape wound protection CT E 3211.00
c12 500/ 5 A, 15 VA, 10 P 5, tape wound protection CT E 2892.00
c13 600/ 5 A, 15 VA, 10 P 10, tape wound protection CT E 2725.00
c14 600/ 5 A, 15 VA, 5 P/ 10 P 10, tape wound protection CT E 3085.00
c15 800/ 5 A, 15 VA, 5 P/ 10 P 10, tape wound protection CT E 2860.00
c16 1000/ 5 A, 15 VA, 5 P/ 10 P 10, tape wound protection CT E 2768.00
c17 1200/ 5 A, 15 VA, 5 P/ 10 P 10, tape wound protection CT E 2918.00
c18 1600/ 5 A, 15 VA, 5 P/ 10 P 10, tape wound protection CT E 3280.00
c19 2000/ 5 A, 15 VA, 5 P/ 10 P 10, tape wound protection CT E 3372.00

875 INDICATION LAMPS AND LEGEND PLATES


LED indicators and push button stations
a1 LED indicators for all voltage ranges - White Colour E 297.00
a2 LED indicators for all voltage ranges - Blue Colour E 238.00
a3 LED indicators for all voltage ranges - Red, Green, Black,
Yellow or Orange Colour E 107.00
a4 Compact integral indicator E 74.00
a5 Flush head push button with 1 NC/ 1 NO block. E 84.00
a6 Illuminated flush head push button with LED E 138.00
a7 Flush head actuator - Red with legend "STOP" with 1 NC
contact. E 272.00
a8 Flush head actuator - Green with legend " START" with 1 NO E 272.00
a9 contact.
Illuminated flush head actuator - Green with legend "ON" with 1
NO contact. E 321.00
a10 Illuminated flush head actuator - Red with legend "OFF" with 1
NC contact. E 310.00
a11 Push button station enclosure with 1/ 2/ 3 hole. E 161.00
a12 Flush head actuator - Red with legend "STOP" with 1 NC contact
and Green with legend "START" with 1 NO contact.
E 389.00
Legend plates
b1 Aluminium anodised Danger Notice Board of size 200 x 150 mm.
with inscriptions ( both in English and Malayalam) and
conventional Skull and Bone in Red colour. E 110.00
b2 Aluminium anodised Danger Notice Board of size 150 x 100 mm.
with inscriptions ( both in English and Malayalam) and
conventional Skull and Bone in Red colour. E 65.00
b3 Aluminium anodised Danger Notice Board of size 125 x 75 mm.
with inscriptions ( both in English and Malayalam) and
conventional Skull and Bone in Red colour. E 45.00
b4 Aluminium anodised Danger Notice Board of size 100 x 75 mm.
with inscriptions ( both in English and Malayalam) and
conventional Skull and Bone in Red colour. E 39.00
b5 Enameled Danger Notice Board of size 250 x 200 mm. with
inscriptions ( both in English and Malayalam) and conventional
Skull and Bone in Red colour. E 218.00
b6 Enameled Danger Notice Board of size 200 x 150 mm. with
inscriptions ( both in English and Malayalam) and conventional
Skull and Bone in Red colour. E 218.00
b7 Enameled Danger Notice Board of size 150 x 100 mm. with
inscriptions ( both in English and Malayalam) and conventional
Skull and Bone in Red colour. E 118.00
b8 Aluminium anodised legend plate of size 100 x 40 mm. with
inscription of BUS BAR CHAMBER . E 25.50
b9 Aluminium anodised legend plate of size 100 x 40 mm. with
inscription of CABLE ALLEY. E 25.50
b10 Aluminium anodised legend plate of size 40 x 20 mm. with
inscription of EARTH. E 9.90
b11 Aluminium anodised legend plate of size 40 x 25 mm. with
inscription of AUTO/ MANUAL. E 11.10
b12 Aluminium anodised semi oval type legend plate with inscription
of ON/ OFF/ FORWARD/ REVERSE/ START/ STOP/ UP/
DOWN/ R PHASE/ Y PHASE/ B PHASE/ TRIP/ OPEN/
CLOSE/ LEFT/ RIGHT/ MOTOR ON/ MOTOR OFF/ ACCEPT/
RETRACT/ RESET/ EMERGENCY/ EMERGENCY ON/
EMERGENCY OFF/ PUMP RUNNING/ PUMP OFF/
EMERGENCY STOP/ SLOW/ FAST or other inscriptions
directed.
E 11.10
Control wiring
880 Carrying out control wiring for panel with normal meters and
indication lamps alone with 650/1100 V grade PVC insulated
stranded single core copper conductor cables conforming to IS
694 part I 1990 for interconnecting the control devices/
equipments including providing suitable size insulated sockets at
the termination points or soldered properly, providing numbering
ferrules for the proper identification of the wiring, keeping the
wiring firm by suitable tie/ tie mounts/ PVC duct etc as required.

a 1.50 sq mm single run with required sockets. m 19.50


b 2.50 sq mm single run with required sockets. m 28.50
c 4.00 sq mm single run with required sockets. m 40.00
881 Carrying out control wiring for panels with sophisticated control
devices such as relays, PLC etc including detailed Engineering,
generating the required drawings according to the logical
requirement etc with 650/1100 V grade PVC insulated stranded
single core copper conductor cables conforming to IS 694 part I
1990 for interconnecting the control devices/ equipments
including providing suitable size insulated sockets at the
termination points or soldered properly, providing numbering
ferrules for the proper identification of the wiring, keeping the
wiring firm by suitable tie/ tie mounts/ PVC duct etc as required
including conducting trial run after completion of the wiring,
making corrections if required and make the system in perfect
working condition.

a 1.50 sq mm single run with required sockets. m 38.50


b 2.50 sq mm single run with required sockets. m 47.50
c 4.00 sq mm single run with required sockets. m 59.00
Part XVIII
890 APFC PANEL
a Fabrication of panel assembly (as for main panel)
Capacitor duty power contactors
b1 Three pole capacitor duty contactors for switching capacitor
banks of 4 to 7 KVAr rating with AC coil and 1 NO contact.
E 1600.00
b2 Three pole capacitor duty contactors for switching capacitor
banks of 7.5 to 10 KVAr rating with AC coil and 1 NO contact.
E 1707.00
b3 Three pole capacitor duty contactors for switching capacitor
banks of 11 to 15 KVAr rating with AC coil. E 2076.00
b4 Three pole capacitor duty contactors for switching capacitor
banks of 16 to 25 KVAr rating with AC coil. E 2861.00
b5 Three pole capacitor duty contactors for switching capacitor
banks of 28 to 50 KVAr rating with AC coil and 1 NO contact.
E 7107.00
b6 Three pole capacitor duty contactors for switching capacitor
banks of 60 KVAr rating with AC coil. E 7979.00
b7 Three pole capacitor duty contactors for switching capacitor
banks of 70 KVAr rating with AC coil. E 13517.00
b8 Three pole capacitor duty contactors for switching capacitor
banks of 80 KVAr rating with AC coil. E 14305.00
Power capacitors suitable for motors
c1 1 KVAr, 3 phase, 440 V, delta connected Metalised Poly
Propylene Capacitor suitable for direct connection to motors. E 270.00
c2 2 KVAr, 3 phase, 440 V, delta connected Metalised Poly
Propylene Capacitor suitable for direct connection to motors. E 505.00
c3 3 KVAr, 3 phase, 440 V, delta connected Metalised Poly
Propylene Capacitor suitable for direct connection to motors. E 740.00
c4 4 KVAr, 3 phase, 440 V, delta connected Metalised Poly
Propylene Capacitor suitable for direct connection to motors. E 975.00
c5 5 KVAr, 3 phase, 440 V, delta connected Metalised Poly
Propylene Capacitor suitable for direct connection to motors. E 1212.00
c6 6 KVAr, 3 phase, 440 V, delta connected Metalised Poly
Propylene Capacitor suitable for direct connection to motors. E 1179.00
c7 7 KVAr, 3 phase, 440 V, delta connected Metalised Poly
Propylene Capacitor suitable for direct connection to motors. E 1362.00
c8 7.5 KVAr, 3 phase, 440 V, delta connected Metalised Poly
Propylene Capacitor suitable for direct connection to motors. E 1576.00
c9 8 KVAr, 3 phase, 440 V, delta connected Metalised Poly
Propylene Capacitor suitable for direct connection to motors. E 1552.00
c10 10 KVAr, 3 phase, 440 V, delta connected Metalised Poly
Propylene Capacitor suitable for direct connection to motors. E 2089.00
c11 12.5 KVAr, 3 phase, 440 V, delta connected Metalised Poly
Propylene Capacitor suitable for direct connection to motors. E 2630.00
c12 15 KVAr, 3 phase, 440 V, delta connected Metalised Poly
Propylene Capacitor suitable for direct connection to motors. E 2906.00
c13 20 KVAr, 3 phase, 440 V, delta connected Metalised Poly
Propylene Capacitor suitable for direct connection to motors. E 3854.00
c14 25 KVAr, 3 phase, 440 V, delta connected Metalised Poly
Propylene Capacitor suitable for direct connection to motors. E 4800.00
Power capacitors suitable for APFC panel without block reactor

d1 5 KVAr, 3 phase, 440 V, delta connected Double dielectric Poly


Propylene Heavy duty Capacitor suitable for APFC panel without
block reactor. E 2920.00
d2 6 KVAr, 3 phase, 440 V, delta connected Double dielectric Poly
Propylene Heavy duty Capacitor suitable for APFC panel without
block reactor. E 2797.00
d3 7.5 KVAr, 3 phase, 440 V, delta connected Double dielectric
Poly Propylene Heavy duty Capacitor suitable for APFC panel
without block reactor. E 3488.00
d4 8 KVAr, 3 phase, 440 V, delta connected Double dielectric Poly
Propylene Heavy duty Capacitor suitable for APFC panel without
block reactor. E 3719.00
d5 10 KVAr, 3 phase, 440 V, delta connected Double dielectric
Poly Propylene Heavy duty Capacitor suitable for APFC panel
without block reactor. E 4544.00
d6 12.5 KVAr, 3 phase, 440 V, delta connected Double dielectric
Poly Propylene Heavy duty Capacitor suitable for APFC panel
without block reactor. E 5704.00
d7 15 KVAr, 3 phase, 440 V, delta connected Double dielectric
Poly Propylene Heavy duty Capacitor suitable for APFC panel
without block reactor. E 6352.00
d8 20 KVAr, 3 phase, 440 V, delta connected Double dielectric
Poly Propylene Heavy duty Capacitor suitable for APFC panel
without block reactor. E 8444.00
d9 25 KVAr, 3 phase, 440 V, delta connected Double dielectric
Poly Propylene Heavy duty Capacitor suitable for APFC panel
without block reactor. E 10538.00
d10 30 KVAr, 3 phase, 440 V, delta connected Double dielectric
Poly Propylene Heavy duty Capacitor suitable for APFC panel
without block reactor. E 12642.00
d11 40 KVAr, 3 phase, 440 V, delta connected Double dielectric
Poly Propylene Heavy duty Capacitor suitable for APFC panel
without block reactor. E 15193.00
d12 50 KVAr, 3 phase, 440 V, delta connected Double dielectric
Poly Propylene Heavy duty Capacitor suitable for APFC panel
without block reactor. E 21018.00
Power capacitors suitable for APFC panel with block reactor

e1 5 KVAr, 3 phase, 520 V, delta connected Double dielectric Poly


Propylene Heavy duty Capacitor suitable for APFC panel with
block reactor. E 4450.00
e2 10 KVAr, 3 phase, 520 V, delta connected Double dielectric
Poly Propylene Heavy duty Capacitor suitable for APFC panel
with block reactor. E 7592.00
e3 12.5 KVAr, 3 phase, 520 V, delta connected Double dielectric
Poly Propylene Heavy duty Capacitor suitable for APFC panel
with block reactor. E 7941.00
e4 15 KVAr, 3 phase, 520 V, delta connected Double dielectric
Poly Propylene Heavy duty Capacitor suitable for APFC panel
with block reactor. E 9516.00
e5 20 KVAr, 3 phase, 520 V, delta connected Double dielectric
Poly Propylene Heavy duty Capacitor suitable for APFC panel
with block reactor. E 12665.00
e6 25 KVAr, 3 phase, 520 V, delta connected Double dielectric
Poly Propylene Heavy duty Capacitor suitable for APFC panel
with block reactor. E 15813.00
Block Reactors
f1 Copper wound block reactor transformer, 400 V, 6 KVAr suitable
for filtering harmonics up to 7% THD E 10571.00
f2 Copper wound block reactor transformer, 400 V, 12.5 KVAr
suitable for filtering harmonics up to 7% THD E 11807.00
f3 Copper wound block reactor transformer, 400 V, 15 KVAr
suitable for filtering harmonics up to 7% THD E 12121.00
f4 Copper wound block reactor transformer, 400 V, 19 KVAr
suitable for filtering harmonics up to 7% THD E 12306.00
f5 Copper wound block reactor transformer, 400 V, 25 KVAr
suitable for filtering harmonics up to 7% THD E 20155.00
f6 Copper wound block reactor transformer, 400 V, 30 KVAr
suitable for filtering harmonics up to 7% THD E 23253.00
f7 Copper wound block reactor transformer, 400 V, 37 KVAr
suitable for filtering harmonics up to 7% THD E 25601.00
f8 Copper wound block reactor transformer, 400 V, 50 KVAr
suitable for filtering harmonics up to 7% THD E 28320.00
Intelligent Power factor Controllers
g1 6 stage, 440/ 110 V, 5 A/ 1 A intelligent power factor controller.
E 11331.00
g2 12 stage, 440/ 110 V, 5 A/ 1 A intelligent power factor controller.
E 14256.00
g3 6 stage, 440/ 110 V, 5 A/ 1 A intelligent power factor controller.
E 16363.00
g4 8 stage, 440/ 110 V, 5 A/ 1 A intelligent power factor controller.
E 18717.00
g5 12 stage, 440/ 110 V, 5 A/ 1 A intelligent power factor controller.
E 21837.00
g6 14 stage, 440/ 110 V, 5 A/ 1 A intelligent power factor controller.
E 23456.00
g7 Static switching power factor controller up to 8 stage E 22249.00
g8 Static switching power factor controller above 8 stage and up to
14 stage. E 26988.00
g9 PPCB for RS 485 communication module. E 8258.00
Control wiring
891 Supply and wiring with 650/1100 V grade PVC insulated
stranded single core copper conductor cables conforming to IS
694 part I 1990 for interconnecting the control devices/
equipments including providing suitable size sockets at the
termination points, keeping the wiring firm by suitable tie/ tie
mounts/ PVC duct etc as required.

a 1.50 sq mm single run with required sockets & numbering


ferrule. E 19.50
b 2.50 sq mm single run without sockets. E 27.00
c 4.00 sq mm single run without sockets. E 39.00
d 6.00 sq mm single run without sockets. E 60.00
e 10.00 sq mm single run without sockets. E 97.50
f 16.00 sq mm single run without sockets. E 152.00
g 25.00 sq mm single run without sockets. E 242.00
h 25.00 sq mm single run without sockets. E 319.00
i 25.00 sq mm single run without sockets. E 461.00
Part XIX
900 METER BOARD AND ACCESSORIES
a Fabrication, supply & installation of dust and vermin proof, wall/
floor mounting, metering cubicle of cubicle construction made
from 1.60 mm CRCA sheet, providing necessary supports made
from the same gauge CRCA sheet to fix KSEB meters, fuse units,
CT etc, hinged door construction for the front side with
compartments if necessary, providing vision panel for the meter
compartment, knock out for cable entry and exit, painting the
entire board with 2 coats of synthetic enamel paint over a coat of
zinc chromate primer etc as required including fixing it on wall,
making good the damages colour washing etc. as required. CRCA
sheet alone be used for the fabrication. Angles/ flats/ slotted
angles etc shall not be used for the fabrication of main housing of
meter board.

m3 6571.00
b Fabrication, supply & installation of dust and vermin proof, wall/
floor mounting, metering cubicle of cubicle construction made
from 1.60 mm CRCA sheet, providing necessary supports made
from the same gauge CRCA sheet to fix KSEB meters, fuse units,
CT etc, hinged door construction for the front side with
compartments if necessary, providing vision panel for the meter
compartment, knock out for cable entry and exit, powder coating
the board after 7 tank chemical treatment etc as required
including fixing it on wall, making good the damages colour
washing etc. as required. CRCA sheet alone be used for the
fabrication. Angles/ flats/ slotted angles etc shall not be used for
the fabrication of main housing of meter board.

m3 8095.00
901 Supply and providing the following size of SMC sheets in the
panel as barriers & shrouding using required bolts and nuts
including cutting to shape etc., as required.
a 2 mm thick E 2740.00
b 3 mm thick E 3658.00
c 4 mm thick E 4673.00
d 5 mm thick E 5832.00
e 6 mm thick E 7176.00
902 Supply and fixing the following types of beeding along the
periphery of doors/ other detachable compartments to make the
panel assembly dust & vermin proof.
a A' section neoprene beeding suitable for 1.60/ 2.00 mm sheet
E 49.00
b U' section rubber beeding suitable for 1.60/ 2.00 mm sheet E 7.00
c U' section PVC beeding suitable for 1.60/ 2.00 mm sheet E 4.50
903 Fabrication, supply, conveyance and installation of base frame
for metering cubicle using channel of class designation ISMC 75
including cutting, welding, drilling holes, painting with two coats
of synthetic enamel paint over a coat of zinc chromate primer,
bolting the frame to the metering cubicle and to the finished floor
using required bolt and nuts, making good the damages etc. as
required.
m 612.00
904 Fabrication, supply, conveyance and installation of angle iron
frame work for the metering cubicle using suitable size angle iron
cut and welded to shape including painting with two coats of
synthetic enamel paint over a coat of zinc chromate primer,
bolting the frame to the panel using required bolt and nuts, fixing
the whole to the wall, making good the damages etc. as required.

Kg 95.50
905 Supply and fixing the following accessories in the existing meter
board and giving connections etc.
BS type fuse units
a1 20 A fuse holder for BS type blade fuses. E 113.00
a2 32 A fuse holder for BS type blade fuses. E 186.00

b1 32 A fuse holder for BS type offset tag fuses. E


b2 63 A fuse holder for BS type offset tag fuses. E 215.00
b3 100 A fuse holder for BS type offset tag fuses. E 535.00
b4 125 A fuse holder for BS type offset tag fuses. E 593.00
DIN type fuse units
c1 32 A, 415 V, DIN type fuse base. E 150.00
c2 63 A, 415 V, DIN type fuse base. E 207.00
c3 100 A, 415 V, DIN type fuse base. E 260.00
c4 125 A, 415 V, DIN type fuse base. E 284.00
c5 160 A, 415 V, DIN type fuse base. E 289.00
c6 250 A, 415 V, DIN type fuse base. E 513.00
c7 400 A, 415 V, DIN type fuse base. E 681.00
c8 630 A, 415 V, DIN type fuse base. E 935.00
2 Way Neutral link
d1 32 A, 415 V, 2 way neutral link mounted on DMC/ SMC base.
E 82.50
d2 63 A, 415 V, 2 way neutral link mounted on DMC/ SMC base.
E 153.00
d3 100 A, 415 V, 2 way neutral link mounted on DMC/ SMC base.
E 237.00

Part XX
MISCELLANEOUS
910 Supplying and installation including all manner of supports/
suspenders, anchor bolts etc for cable trays made out of suitable
size channel sections, slotted angles, flats, MS plates etc as
required including painting with 2 coats of synthetic enamel paint
over a coat of zinc chromate primer, making good the damages,
colour washing etc as required.
Kg 87.00
911 Supplying and installation of supports, anchor bolts etc made out
of suitable size single section MS angle, flats etc as required
including painting with 2 coats of synthetic enamel paint
Kg 61.00
912 Supplying and installation of supports, anchor bolts etc made out
of suitable size single section channel etc as required including
painting with 2 coats of synthetic enamel paint
Kg 60.50
913 Supply and providing MS chequered plate of suitable thickness
including cutting, welding, painting etc. as required for the cable
trench covering. Kg 60.00
914 Supply and providing SMC chequered plate of the following
thickness including cutting, fixing with the existing frame-work
etc. as required for the cable trench covering.
a 8 mm thick m2 8998.00
b 10 mm thick m2 11246.00
915 Supply and providing 6 mm thick & 1 m wide electrical grade
chequered type rubber mat to withstand 3.3 KV dielectric
strength conforming to IS 5429/ 1969. m2 646.00
916 Supply and providing 12 mm thick & 1 m wide electrical grade
chequered type rubber mat to withstand 15 KV dielectric strength
conforming to IS 5429/ 1969. m2 1113.00
917 Supply and providing 5 Kg. Dry Chemical Powder type Fire
Extinguisher with hose and clamps including fixing it to wall as
required. E 2190.00
918 Supply and providing 9 Litre capacity GI Fire Bucket painted in
post office red with primer coat of red oxide and written with
white paint 'FIRE' mounted on MS angle frame work/ wall
bracket filled with fine sand, painting the bracket/ floor stand
including making good the damages, colour washing etc. as
required.
E 133.00
919 Supply and providing First Aid Chart duly framed and placed in a
conspicuous location for clear vision. E 184.00
920 Painting letters or figures of the following sizes with enamel
paint as identification mark to SB, DB, panel board etc as
required
a 2.50 cm, 4 cm or 5 cm height E 8.30
b 6.5 cm, 8 cm or 13 cm height E 19.20
Part XXI
CIVIL ITEMS
Earth work excavation
950 Earth work excavation in ordinary soil and depositing with a lead
a1 up to 50 m and lift up to 1.50 m including neat banking m3 81.77
a2 Earth work excavation in ordinary soil and depositing with a lead
up to 50 m and lift above 1.50 m but up to 3.00 m including neat
banking m3 92.74
a3 Earth work excavation in ordinary soil and depositing with a lead
up to 50 m and lift above 3.00 m but up to 4.50 m including neat
banking m3 103.78
951 Earth work excavation in hard soil and depositing with a lead up
a1 to 50 m and lift up to 1.50 m including neat banking m3 151.11
a2 Earth work excavation in hard soil and depositing with a lead up
to 50 m and lift above 1.50 m but up to 3.00 m including neat
banking m3 162.29
a3 Earth work excavation in hard soil and depositing with a lead up
to 50 m and lift above 3.00 m but up to 4.50 m including neat
banking m3 173.33
952 Earth work excavation in ordinary rocky soil (soft laterite) and
a1 depositing with a lead up to 50 m and lift up to 1.50 m including
neat banking m3 280.83
a2 Earth work excavation in ordinary rocky soil (soft laterite) and
depositing with a lead up to 50 m and lift above 1.50 m but up to
3.00 m including neat banking m3 291.87
a3 Earth work excavation in ordinary rocky soil (soft laterite) and
depositing with a lead up to 50 m and lift above 3.00 m but up to
4.50 m including neat banking m3 302.91
953 Earth work excavation (including refilling) in ordinary soil and
a1 depositing with a lead up to 50 m and lift up to 1.50 m including
breaking clods, watering, ramming and sectioning of spoil bank
etc complete
m3 92.46
a2 Earth work excavation (including refilling) in ordinary soil and
depositing with a lead up to 50 m and lift above 1.50 m but up to
3.00 m including breaking clods, watering, ramming and
sectioning of spoil bank etc complete
m3 103.50
a3 Earth work excavation (including refilling) in ordinary soil and
depositing with a lead up to 50 m and lift above 3.00 m but up to
4.50 m including breaking clods, watering, ramming and
sectioning of spoil bank etc complete
m3 104.60
954 Earth work excavation (including refilling) in hard soil and
a1 depositing with a lead up to 50 m and lift up to 1.50 m including
breaking clods, watering, ramming and sectioning of spoil bank
etc complete
m3 172.50
a2 Earth work excavation (including refilling) in hard soil and
depositing with a lead up to 50 m and lift above 1.50 m but up to
3.00 m including breaking clods, watering, ramming and
sectioning of spoil bank etc complete
m3 183.54
a3 Earth work excavation (including refilling) in hard soil and
depositing with a lead up to 50 m and lift above 3.00 m but up to
4.50 m including breaking clods, watering, ramming and
sectioning of spoil bank etc complete
m3 194.58
955 Earth work excavation (including refilling) in ordinary rocky soil
a1 (soft laterite) and depositing with a lead up to 50 m and lift up to
1.50 m including breaking clods, watering, ramming and
sectioning of spoil bank etc complete
m3 323.61
a2 Earth work excavation (including refilling) in ordinary rocky soil
(soft laterite) and depositing with a lead up to 50 m and lift above
1.50 m but up to 3.00 m including breaking clods, watering,
ramming and sectioning of spoil bank etc complete

m3 334.65
a3 Earth work excavation (including refilling) in ordinary rocky soil
(soft laterite) and depositing with a lead up to 50 m and lift above
3.00 m but up to 4.50 m including breaking clods, watering,
ramming and sectioning of spoil bank etc complete

m3 345.69
956 Brick work in cement mortar 1:6 with country burnt bricks 19cm
x 9cm x 9cm for foundation and basement. m3 2965.38
957 Plastering with cement mortar 1:4, 12mm thick one coat. m2 142.73
958 Plain cement concrete 1:4:8 using 40mm ( Normal size ) broken
stone. ( m3 )
m3 3431.20
959 Cement concrete 1:2:4 using 20mm (nominal size) broken stone
for reinforced concrete work. m3 5064.66
960 Cement concrete 1:3:6 using 20mm (nominal size) broken stone
for reinforced concrete work. m3 4448.45
961 Cement concrete 1:4:8 using 20mm (nominal size) broken stone
for reinforced concrete work. m3 4156.58
962 Reinforcement for R.C.C works, bend tied and placed in position
(plain grill requiring bend cold) using tor steel Kg 59.88
963 Form work for reinforced cement concrete in slabs including
wooden planks, joists, bamboo posts and labour for taking down
after completion of work (Hire and labour charges only)
m2 326.36
964 Colour washing, two coats m2 7.08
###
###
###
###
###

46.50
6.20
4.10
OL & SC protection
GROUP B
17265
```