Power and Surge Protection

for CCTV Systems


Catalogue
Rely on Clearline, where quality
is a standard product.

At Clearline, we endeavour to bring you the latest protection developments


that will safely protect your equipment from the damaging effects of
lightning and power surges. With a large emphasis placed on research
and development, we offer the latest protection technology and have
distribution networks both nationally and internationally.

Founded in 1985, Clearline has 22 years experience in the protection solutions


industry and with over 400 products designed for power, telecommunications,
security, CCTV, process control and consumer applications, we have the
technical expertise to help our customers obtain the correct products for
their speci fic applications.

Clearline is ISO 9001 cer tified and with some 75 employees, we are
dedicated to customer support, with a special division offering on-going
customer training and in-depth courses available to interested parties to
enable them to bene fit from their protection system… Clearline Protection Systems (Pty) Ltd.
P.O. Box 5985, Halfway House, 1685
E-mail: sales@clearline.co.za
You can rely on Clearline. Customer care line: 0860 204040
tec tion
rge Pro
and Su ms
Power ste
r C C TV Sy
fo
gue
Catalo

Table of Contents
4 Coaxial Protection
- Video surge protection
- Video protected Patch Panel

5 Camera Protection
- Video & DC Power surge protection (Static Cameras)
- Video, DC Power, and RS485/422 surge protection (PTZ Cameras)
- Video, 250VAC Power, and RS485/422 surge protection (PTZ Cameras)
- 100 Base T for IP Camera Systems

6 Fibre Optic Products


- Fibre Optic Video Receiver
- Fibre optic Video Transmitter
- Fibre Optic Kit - 1 x 12-00135, 1 x 12-00794, 2 x PSU
- 16 Channel Fibre Patch Panel with integrated Power Supply
- RS422/RS485 Fibre Optic Converters
- Din Rail Power Supply

8 General Protection
- Protected Plug Tops
- Protected Plug Strips and Combination Strips
- Primary and Secondary Power Protection
- Accessories

9 Smart Power
- Power Supplies
Clearline Platform Concept
h

The key to Clearline’s success is the equi-potential platform.


During a transient event the voltage potentials between power, data, and video lines can rise to several thousands of
volts causing extensive damage and costly down time to surveillance systems.

Simply protecting the power, data, or video line individually, provides little or no protection against this type of transient.
In order to prevent damage, a common, low impedance path “around” the sensitive components needs to be provided.
Clearline’s unique protection platform not only provides protection for each of the connected lines but also a low
Power and Surge Protection

impedance path between protection devices ensuring safe diversion of transient current even when there is a poor
earth available.

- Equi potential
Platform
Equi-potential
Video Control Room Platform
Video
Data Video
Data
12/24V Data
12/24V Control Room
Power
PSU

220V I 220V
PSU
220V I 220V

500KV 500KV

100KV 100KV
50KV 50KV

Transient current flows through camera and control room equipment Transient current flows through low impedance equipotential platform
due to potential differences in earthing systems preventing damage to equipment

Coaxial Protection
Video Surge Protection
This unit is an in-line protection device designed to protect against surges originating on coaxial video cables.

Features
Easy installation
Low insertion loss
Failsafe protection
CCTV Systems Catalogue

Specifications 12-00199 12-00299


Max. operating voltage 1V p-p 1V p-p
Max. discharge current common mode 10kA 10kA
Insertion loss at 10MHz 0.08dB 0.08dB Order code: 12-00199

Connectors BNC M-F BNC F-F

4
Video Protected Patch Panel
The 12-00321 is a 483mm (19 inch) 1 U rack mountable patch panel that allows up to 16 coaxial
protectors to be fitted. This unit offers cable management and comes with mounting hardware.
This unit is ideal for protecting video inputs to DVR’s.

Specifications 12-00614 12-00321 12-00503 Order code: 12-00321

Panel loaded with: 16x12-00199 16x12-00299 Panel only

Power and Surge Protection


Note:
It is crucial to ensure that the power and video inputs are protected and that the two protection devices are bonded
together to the electrical earth.

Camera Protection
Video & DC Power Surge Protection (Static Cameras)
The 12-00027 combined video and power surge arrester is based on the surge platform
concept and will fully protect a camera system even where no connection to earth is available.

Specifications 12-00027 12-00499


Max. operating voltage - Video 1V p-p 1V p-p
Max. operating voltage - DC feed 15VDC 36VDC
Max. discharge current - Video 10kA (8/20) 10kA (8/20)
Max. discharge current - DC feed 2500A (8/20) 2500A (8/20)

Max. current - DC feed 1A 1A

Insertion loss at 10MHz 0.08dB 0.08dB


Order code: 12-00027
Connectors BNC F-F F-F

Video, DC Power, and RS485/422 surge protection


(PTZ Cameras)
Combination protection for CCTV with PTZ control. Will accommodate high speed data transmission lines.
Implementation of surge platform gives a high degree of protection in the absence of a low impedance earth connection.

Specifications 12-00170 12-00171


Max. operating voltage - Video ±1.5V ±1.5V
CCTV Systems Catalogue

Max. operating voltage - DC feed 15VDC 36VDC / 24VAC


Max. operating voltage - Data 6.8V 6.8V
Max. current - Video 0.3A 0.3A
Max. current - DC feed 1A 1A
Max. current - Data 0.4mA 0.4mA
Max. discharge current - Video 10kA 10kA
Max. discharge current - DC feed 2.5kA (8/20) 2.5kA (8/20)
Max. discharge current - Data 5kA (8/20) 5kA (8/20)
Insertion loss at 10MHz 0.08dB 0.08dB
Connectors BNC F-F F-F
5
Video, 220VAC Power, and RS485/422 surge protection
(PTZ Cameras)
Specifications 12-00729
Max. operating voltage - Video ±1.5V
Max. operating voltage - AC feed 220v 50HZ
Max. operating voltage - Data 5V
Max. current - Video 0.3A
Power and Surge Protection

Max. current - AC feed 10A


Max. current - Data 0.3A
Max. discharge current - Video 8kA (8/20)
Max. discharge current - AC feed 10kA (8/20)
Max. discharge current - Data 10kA (8/20)
Insertion loss at 10MHz 0.08dB Order code: 12-00729
Connectors BNC M-F

100 Base T for IP Camera Systems


Specifications 12-00354
Clamping voltage <10V (1.2/50)
Max. discharge current - coarse protection 2500A (8/20)
Max. discharge current - fine protection 300A (8/20)
Pairs protected 1-2, 3-6, 4-5, 7-8
Test frequencies in Mhz 20 62.5 100

Insertion loss in dB (with RJ45 sockets) 0.13 0.39 0.83


Next limits as per IEC 11801 >40.7 (35) >30.7 (27) >29.1 (24)
Return loss limits as per IEC 11801 >27.8 (15) >31.4 (10) >22.8 (10) Order Code: 12-00354

Data rate >100Mbits/s


Band width (3dB per pair) >220MHz
Standards compliance Fast Ethernet 802.3U, IEC 11801
And IEEE 502.3

Fibre Optic Protection


Fibre Optic Video Receiver
Specifications 12-00135
Bandwidth 30Hz to 16MHz -3dB AGC + 12dB
AGC dynamic range 12dB
Receiver S/N ratio >42dB
CCTV Systems Catalogue

Output signal 1Vpp


Output impedance 75⇓ unbalanced
Power supply (12-00022) + 5 - 0 - -5 VDC 100mA
Operating temperature -10°C to +70°C
Optical fibre 62.5/125mm multi mode
Connectors (optical/electrical) ST/BNC female Order code: 12-00135
Range 2000m
Dimensions 37.5mm x 25mm x 80mm

6
Fibre Optic Video Transmitter
Specifications 12-00794
Bandwidth 30Hz to 16MHz -3dB
Modulation current laser diode 40mA
Input signal 1Vpp
Input impedance 75⇓ unbalanced
Power supply (12-00801) 12VDC 150mA
Operating temperature -10°C to +70°C
Order code: 12-00794
Optic fibre 62.5 / 125 multi mode
Connectors (optical/electrical) ST/BNC male
Dimensions 25mm x 25mm x 85mm

Power and Surge Protection


Fibre Optic Kit - 1 x 12-00135, 1 x 12-00794, 2 x PSU
This fibre optic kit consists of a receiver and transmitter unit with power supplies.
Both units and fibre cables are immune to EMI/RFI, eliminating any need for
concern in noisy environments. These devices are easy to install and will isolate
your CCTV systems from lightning damage.

Fibre Optic Kit


Order Code: 12-00047

16 Channel Fibre Patch Panel with Integrated Power Supply


A 2-U universal panel that will accept a total of 16 coaxial protectors or fibre receivers or a combination of both for the
protection of CCTV camera systems. The power supply unit houses up to four, 4 channel power supply boards, each
board supplying 4 fibre optic receivers. (see 12-00135). Suitable for mounting in modem racks and the unit can be
used as a patch panel.
16 port panel only 12-00205
4 channel power supply 12-00216

RS422/RS485 Fibre Optic Converters


Fibre Optic converters offer superior levels of protection by galvanically isolating components to a network. It is important
to note however that the power to the units still requires protection, if power supply 12-00923 is not used.

12-00874 (Glass) 12-00876 (Glass)


Specifications
RS422-RS422 RS485-RS485
Max. operating voltage +/-5Vp +/-5Vp
Signal lines (copper) Rx+ / Rx- Tx+ / Tx- Rx / Tx
Number of wires (copper) 4 to 4 2 to 2
Transmission mode Full duplex Half duplex
Fibre wavelength Multimode 850nm Multimode 850nm
Data speed >1Mbits/s 1Mbits/s
Transmission distance - glass fibre
CCTV Systems Catalogue

>2500M >2500M
Power supply External 24VDC / 5VDC 200mA supply

Din Rail Power Supply


This din rail power supply supplies 2 x 5V isolated outputs at 0.5A each for use with the RS422 or
RS485 fibre optic invertors. Easy to install, these units clip onto a standard 35mm din rail.
Connections are via screw terminals and power indicators have been provided.

Order code: 12-00923 7


General Protection Products
Protected Plug Tops
Specifications
Max. continuous voltage 275V 50Hz
Order codes:
12-00116 Keyed Max. discharge current Ismax (8/20) 8kA
12-00815 Keyed with LED
Residual voltage at Ismax Approx. 900V
Response time <25ns
Power and Surge Protection

12-00055 Standard Temperature range -10°C to +70°C


12-00760 Standard with LED
IEC 61643-1, IEC 99.4
Standards compliance
and ANSI C 62.41
Available with or without failure indication.

Duo Line Protected Plug Strips and Combination Strips


A range of power strips and combination power and data strips are available to protect most computer/DVR
configurations.
6-way 19” Rack mounted power only Combination Power, 100BaseT, Modem Combination power & 100BaseT

Order code: 12-00841 Order code: 12-00960 Order code: 12-00897

Primary and Secondary Power Protection


Din rail mounted 40kA primary 40kA general purpose parallel 8kA general purpose series
protection for use in DBs. connected primary protection connected secondary protection

Order code: 12-00237 Order code: 12-00370 Order code: 12-00138

Primary and Secondary Power Protection


8kA general purpose plug in power protection General purpose 15VDC, 24VAC power and data protection
CCTV Systems Catalogue

Order code: 12-00185 - 15V


8 Order code: 12-00025 12-00187 - 36V
Accessories

Box size 214 x 162 x 71 Box size 214 x 162 x 71 Box size 180 x 150 x 55 Box size 180 x 150 x 55
with screw on lid with screw on lid with slide on lid with slide on lid

Power and Surge Protection


Order code: 12-00141 Order code: 12-00142 Order code: 12-00148 Order code: 12-00149

Enclosures supplied with mounting plate but without protectors.

Smart-power
These power supplies are intended for installations in which the CCTV cameras are remote to the control and
recorder system. They are wall mountable, and offer a wide range of possible installation structures. From the tiny
SP1 which provides 16VAC for alarm applications, to the SP5, which offers power for up to eight cameras from the
same device, our range of CCTV power supplies meets every need in your security application. We offer a battery
back-up version in the SP4 model.

5
3 4

Order code: 12-00748 Order code: 12-00630 Order code: 12-00631 Order code: 12-00633 Order code: 12-00640

Model Number SP1 SP2 SP3 SP4 SP5


Part number 12-00748 12-00630 12-00631 12-00633 12-00640
Output voltage 16VAC 13.8VDC 13.8VDC 13.8VDC 13.8VDC
Number of outputs 1 1 4 1 8
Output current 1A 3A 0.8A each 3A 0.8A each
Ripple voltage Self resettable fuse <100mV <100mV <100mV <100mV
Overload protection - 5A fuse 1A fuse 5A fuse 1A fuse
CCTV Systems Catalogue

DM Surge protection 4kA 4kA 4kA 4kA 4kA


CM Surge protection - 4kA 4kA 4kA 4kA
Output connections Screw terminal Screw terminal Screw terminal Screw terminal Screw terminal

Input voltage 230VAC 230VAC 230VAC 230VAC 230VAC

Input connections Screw terminal 16A plug 16A plug 16A plug 16A plug

Battery back-up - - - 2Hrs at 3A -

9
Notes:............................................................................................................................... ............................................................
...........................................................................................................................................................................................................

...........................................................................................................................................................................................................

...........................................................................................................................................................................................................

...........................................................................................................................................................................................................

...........................................................................................................................................................................................................

...........................................................................................................................................................................................................

...........................................................................................................................................................................................................

...........................................................................................................................................................................................................

...........................................................................................................................................................................................................

...........................................................................................................................................................................................................

...........................................................................................................................................................................................................

...........................................................................................................................................................................................................

...........................................................................................................................................................................................................

...........................................................................................................................................................................................................

...........................................................................................................................................................................................................
...........................................................................................................................................................................................................

...........................................................................................................................................................................................................

...........................................................................................................................................................................................................

...........................................................................................................................................................................................................

...........................................................................................................................................................................................................

...........................................................................................................................................................................................................

...........................................................................................................................................................................................................

...........................................................................................................................................................................................................

...........................................................................................................................................................................................................

...........................................................................................................................................................................................................

...........................................................................................................................................................................................................

...........................................................................................................................................................................................................

...........................................................................................................................................................................................................

...........................................................................................................................................................................................................
...........................................................................................................................................................................................................

...........................................................................................................................................................................................................

...........................................................................................................................................................................................................

...........................................................................................................................................................................................................

...........................................................................................................................................................................................................

...........................................................................................................................................................................................................

...........................................................................................................................................................................................................

...........................................................................................................................................................................................................

...........................................................................................................................................................................................................

...........................................................................................................................................................................................................

...........................................................................................................................................................................................................

...........................................................................................................................................................................................................

...........................................................................................................................................................................................................
For more
information contact
+27 (0) 11 848-1100.

Equipment Warranty
Clearline offers a two year carry-in warranty on all its data protection products even if they have
been damaged by lightning. Each product carries a serial number and if the product is within
the warranty period, Clearline will either repair or replace the unit at no charge to the customer.
This warranty will be void if the unit has been tampered with in any way. Power surge arresters
carry a ten year carry-in warranty.

Connected Equipment Warranty


Some products carry a two year connected equipment warranty. Under this warranty, Clearline
will either repair or replace the connected equipment providing that the equipment has been
registered as per terms and conditions included with each product. Information on this warranty
may be obtained on our website www.clearline.co.za or call 0860204040.
Your reliable
partner in power
and surge protection

Clearline Protection Systems (Pty) Ltd.


Head Office: Roan Crescent Corporate Park North (Old Pta Road) Midrand, South Africa
P.O. Box 5985, Halfway House, 1685
Tel: +27 (0) 11 848-1100
Fax: +27 (0) 11 314-3880
E-mail: sales@clearline.co.za
www.clearline.co.za

You might also like