Order Information

MiCOM P139
Feeder management and Bay Control P139 P139- 9 0 -306 -4xx -611 -7xx -46x -9 x x -9 x x -8xx

Basic device :
Basic device 40TE, pin terminal connection 3 -408
Basic device 40TE, CT/VT ring-, I/O pin terminal connection 5 -409
Basic device 84TE, ring terminal connection 8 -410
basic complement with 4 binary inputs and 8 output relays
and 6 binary inputs and 6 output relays for
the control of 3 switchgear units.

Mounting option and display :


Surface mounted, local control panel with graphic display 5
Flush mounted, local control panel with graphic display 6

Current transformer :
2)
Inom = 1A / 5A (T1 to T4) resp. 22.5mV at 50A for NCIT 9

Voltage transformer :
Without 0
Vnom = 50V … 130V (4-pole) 4
Vnom = 50V … 130V (5-pole) f. Automatic Synchronism Check 5

CT/VT- Boards with NCIT : 9)


Variant 1 : 22.5 mV at 50 A, 3.25 V at Vnom 9

Additional binary I/O options :


Without 0
With 1 binary module (add. 6 binary inputs and 6 output relays) 5
for the control of up to 3 switchgear units

Power supply and additional outputs :


VA,nom = 24 VDC 3
VA,nom = 48 ... 250 VDC/100 ... 230 VAC 4
VA,nom = 24 VDC and 6 output relays, 4 with thyristor 6
VA,nom = 48 ... 250 VDC/100 ... 230 VAC and 6 output relays, 4 with thyristor 7
VA,nom = 24 VDC and 6 output relays 8
VA,nom = 48 ... 250 VDC/100 ... 230 VAC and 6 output relays 9

Further add. Options :


Without 0
3) 10)
With TGF (transient ground fault direction determination) module 1
With analogue module 2
3) 10)
With TGF and analogue module 3
With binary module (add. 24 binary inputs) 4
3) 10)
With TGF and binary module (add. 24 binary inputs) 5
3)
With RTD module 7
3)
With RTD and analogue module 8
3)
With RTD module and binary module (add. 24 binary inputs) 9

Switching threshold on binary inputs :


>18 V (standard variant) (Without order extension No)
>90 V (60...70% of VA,nom = 125...150 V) 8) -461
8)
>155 V (60...70% of VA,nom = 220...250 V) -462
8)
>73 V (67% of VA,nom = 110 V) -463
8)
>146 V (67% of VA,nom = 220 V) -464

With communication / information interface :

Without SCADA communication interface


Only IRIG-B input for clock synchronisation -9 0 0
Protocol can be switched between: -9 2
IEC 60870-101/-103, Modbus, DNP3.0, Courier
and IRIG-B input for clock synchronisation
and 2nd interface (RS485, IEC 60870-5-103)
For connection to wire, RS485, isolated 1
For connection to plastic fibre, FSMA connector 2
For connection to glass fibre, ST connector 4

Protocol IEC 61850 -9 4


For connection to 10 Mbit/s Ethernet, glass fibre ST and wire RJ45
5
and 2nd interface (RS485, IEC 60870-5-103)
For connection to 100 Mbit/s Ethernet, glass fibre SC and wire RJ45
6
and 2nd interface (RS485, IEC 60870-5-103)

With guidance / protection interface :


Without InterMiCOM

Protocol InterMiCOM -9 5
For connection to wire, RS485, isolated 1
For connection to plastic fibre, FSMA connector 2
For connection to glass fibre, ST connector 4
For connection to wire, RS232, isolated 5

Language :
English (German) 4) (Without order extension) -800
4)
Px40 English (English) (Not yet available) -800
4)
German (English) -801
4)
French (English) -802
4)
Spanish (English) -803
4)
Polish (English) (Not yet available) -804
4)
Russian (English) (-605-703 available now, -611-709 on demand) -805

2)
Switching via parameter, default setting is underlined!
3)
This option is excluded if the InterMiCOM ( -95x) is ordered
4)
Second included language in brackets
7)
Hardware option, supports Cyrillic letters instead of special Western European characters
8)
Standard variant recommended, if higher pickup threshold not explicitly required by the application
9)
NCIT (non-conventional instrument transformer) option for variants with either pin terminals only or ring terminals only
10)
Transient ground fault option for variants with current and voltage transformers only

Page 1 P139 cortec.xls 08/01/2007