Power Factor Correction


Low Voltage System

Save energy and reduce Carbon dioxide emission!

FRANKE GMKP LTD.


Http://www.frankegmkp.com
Berlin,Frankfurt,Germany
Tel: 0049 30200033043
Email:info@frankegmkp.com
C1607 Software Park, National Hi-Tech
Industry Development Area, Wuxi
Tel: 0086 510 85211911
Fax: 0086 510 85215070
Email:info@frankeenergy.com
FRANKE, a leading manufacturer with German Quality

Company brief

FRANKE GMKP is a leading


company for design, manufacturing
& marketing of Power Factor
Correction, Energy Management
and Intelligent Power Efficiency
located in Berlin Germany.

Many years of continuous


technology development leads
FRANKE GMKP now to one of the All our products are not only
world’s best quality and solution designed to highest international
provider of Power Quality and standards and certificates, moreover
Energy Efficient system, as well as FRANKE GMKP also focuses on
all needed components and devices highest customer satisfaction,
reliability and system integrity, also
FRANKE GMKP’s system of quality
Following our high German assurance has been approved by
technology standard FRANKE the highest international standards.
GMKP became a international
operating company with distributors, Our customer service has a top
manufacturers and administrative priority in order to provide
centres in Germany, England, comprehensive and versatile
China, India, Turkey, Italy, Hong support and establish a mutually
Kong and many more. Our customer beneficial, long term corporation and
are including many world’s top partnership.
companies like Siemens, ABB,VW
and so on, we are pride that we are In addition FRANKE GMKP has the
an important supplier of many world ability to provide individual solutions
famous brand-capacitor according costumers request.
manufacturers for their (OEM)
production!
What means Power Factor Correction?

Reactive power

All electrical machines (motors, transformers) need from the network; this power is
consuming AC current use two types of power: considerable: 25% to 35% of the active power
active power and reactive power. at full load, much less at partial load.

Only active power (kW) is transformed into Asynchronous motors are universal and the
mechanical power and heat. main consumers of the reactive power
produced by industrial networks.
Reactive power (kvar) is used to magnetize the
core of the electrical machines (transformers Lines and cables:
and motors), allowing them to operate. The L and C characteristics of overhead lines
are such hat they consume reactive power at
The technical consequences of the flow of full load.
reactive power highly influence the selection of
equipment and operation f the networks, However, insulated cables have a capacity of
bringing about economic consequences. 15 to 20times the capacity of overhead lines:
average approximate values for single-pole
The flow of reactive power in transmission and cables:
distribution networks causes: X=0.15Ω/km C=from 0.3 t o 0.5µF/km.

▇ transformer overloads; Transformers:


Transformers consume reactive power which
▇ voltage drops at line ends; corresponds to approximately 5% to 10% of the
apparent power which flows through them.
▇ a rise in temperature in the supply cabbies,
Inductances:
producing losses of active power;
Inductances consume only reactive power: HV
limitation inductances, stabilization inductances
▇ over sizing of load protection due to
(arc furnaces, fluorescent lamps), etc…
harmonic currents.

These 4 reasons make it necessary to bring Static converters:


reactive power as close as possible to the All rectifiers and converters consume reactive
motors and transformers. power.

This is why capacitors used as generators of Capacitors:


reactive power. By definition, capacitors generate reactive
power at very high rate, which is why they are
Consumption and production of reactive used for this application.
power by network components
Definitions
An electrical network is characterized by ▇ active power P=UI cos in W
resistances, reactors and capacitances:
▇ reactive power Q= UI sin in var
▇ the resistance R which transforms electrical ▇ apparent power S= UI in VA
power directly and irreversibly into heat.

▇ the inductance L which transforms electrical


For the three-phase capacitors, the 3 powers should be
power into mechanical power or into another multiplied by . The following graph shows these
type of electrical power , by the means of the
magnetic field produced by the current. relations. The powers in the diagram can be converted
into current (by dividing the powers by the voltage).Each
▇ the capacitance C which, most often, active and reactive power has a corresponding active
produces reactive power. and reactive current (magnetizing current).The active
and reactive currents are added to produce an apparent
Synchronous machines: current, which is the current passing through the line from
By definition, these machines are used as the source to the load.It= I total current (flowing in
generators (of active power) when they conductors) Ia= active current transformed into
transform mechanical energy into electrical mechanical power or heatIr= reactive current needed for
power; otherwise they are used as motors. magnetic excitation f loads

These machines can produce reactive power if Ia= It cos Ir=It sin
the excitation varies.In some cases, the
machine does not supply any active power; it is
then used as a synchronous phase converter. Cos , called the power factor, is active power (kW)
Synchronous motors are rarely used as
divided by consumed power (kVA) A good cos
modulating devices.
optimizes the transformers and the lines. Optimization

Asynchronous machines: improves as cos tends towards 1.


They are different from the machines described
above in that they draw the reactive power they
FRANKE’s Technology of Low Voltage Capacitors

General Information

The power capacitors produced by All GMKP power capacitors have


FRANKE GMKP were specially designed cylindrical extruded aluminium housing
for reactive power compensation. Using with a special three cascade sealing
state of the art technology and method for the capacitor cane to provide
high-quality materials have enabled us to leaks. Another FRANKE GMKP’s special
develop a range of capacitors to meet the is the double safety system, which not only
demands of the future. Furthermore protect in case of overpressure, but also
FRANKE GMKP’s products and system of switch the capacitor off in case of
manufacturing and service is part of the over-current. The purpose is to protect the
new environmental protection industry capacitor against excessive pressure
and will strongly work further to improve increase inside. The inner connections are
our world’s conditions. separated for this purpose from the main
supply.
GMKP type name
The internal construction includes
FRANKE GMKP’s registered type name
lengthwise separate windings of high
worldwide based on FRANK GMKP’s own
quality, resistant, metalized polypropylene
special German technology.
films. For example, a three phase
FRANKE GMKP prime advantages are: capacitor has therefore three windings.
The quality of the polypropylene film is
• completely dry capacitor construction,
so there are no possibility of out flow significantly responsible for the
• special one form capacitor cane, also self-healing ability of the capacitors and so
minimize possibilities for leaks our special metallization procedure
• no PCB using
ensures a high degree of capacitor
• filled with protective gas
• fireproofing self-healing.
• overpressure and over-current tear off
fuse Our capacitors are delivered with the
• self healing polypropylene foil appropriate discharge resistors. FRANKE
• stable fixed connection GMKP’s special design is the internal
• long life working
resistors. In case of high power

Construction features consumption we so avoid arcs outside the


capacitor to protect the equipment from

For capacitors long life properly working burning and over-heating. Another
Excellent self-healing element
the construction and manufacturing advance of this design is to reduce the

process has high priority and is constantly time for discharging in addition with very

observed by FRANKE GMKP’s specialists. low resistor losses and at least safe space
for installing the capacitor.
厂家
Low Voltage Capacitors
Application
Internal discharge resistor
Automatic power factor correction
Terminal for high capacity cables
(PFC) and capacitor banks (up to 16 to 32mm²) , both side of the
Individual solution for fixed power terminal can be used
factor correction (e.g. Motor,
transformers, lighting etc.) Mounting
Group fixed power factor correction Reduced mounting costs
(several equipment connected in a Any position mounting
group) Maintenance-free
Capacitor banks of tuned and
Environment
detuned
Non-pollution, Non PCB
Harmonic trap applications (e.g. Environmentally friendly manufactured
UPS, frequency drives and Recyclable
converters etc.) Easy to dispose
Special application such as outdoor Save energy and reduce Carbon dioxide
mounting, filter model, bushing emission!
terminal style etc.
Safety
Dry type design
Benefit:
Self-healing type
Electrical
Overpressure and over-current
Long life cycle (100000 hours)
disconnector
Highest pulse current withstand
Non-flammable
capability (200 x IN)
Touch-proof terminals
Corona-free
Three cascade cylinder sealing
very low losses
One form capacitor cane, no possibility
for leaks
General Technical Data
Over voltages U UN+10%(up to 8h daily)/UN+15%(up to 30 min daily).UN +30%(up to 1 min)/

Over current Imax Min.1.3*IN(in certain cases higher)

Inrush current Is 200 times rated current(other request is available)

Losses (dielectric) ≤0.20 W/KVar

Capacitance tolerance -5%/+5%

Test voltage terminal to UTT 2.15*UN, AC, 10S


terminal
Test voltage terminal to UTC Up to UN=≤660V:3000VAC, 10s;above UN=660V:6000 VAC, 10s
case
Life expectancy TLD(CO 100,000 operating hours.(other request is available)
)
Ambient temperature LCT/ -25/D, max, 55℃, with forced cooling conditions higher ambient temperature
category UCT possible.
Cooling Naturally air-cooled (of forced air cooling)

Permissible max Hrel 95%


humidity
Maximum permissible Normal 1000 M above sea level (Max.3000M)
Double safety system altitude
Mounting position Any position , normal stand mounting

Mounting and Threaded M12 or M16 stud on bottom of case


grounding
Safety features Dry technology, overpressure/current disconnector , self-healing,

Discharge resistors Internal discharge module design included in delivery, (<75V within 3 min)

Case Extruded aluminium can without any impress

Degree of protection IP20, indoor mounting (optionally with cover for IP55)

Impregnation Non-PCB, resin colloid or resin mixed with the protection gas.

Terminals Dual, with electric shock protection, max, cross-section 16 mm2 cable

Installation Indoor and outdoor (with the cover)

Standards IEC60831-1+2, EN60831-1+2, VDE0560-46+47, CE.(UL marking on request)


Low Voltage Capacitors
Low Voltage Capacitors

Mounting draw

Three cascade sealing process


Low Voltage Capacitors

Robust / dual terminals

High vacuum processing system


r Low Voltage Reactors

The increasing uses of modern power electronic apparatus are producing non-liner
current influences and load the network with harmonics pollution. The capacitor
forms a resonant with the feeding transformer (250-500Hz), it lead to overloading of
capacitor and transformer, interference, voltage distortion; etc. These can be
avoided by filter reactors.

The function of the reactors is to protect capacitors in low voltage power factor
correction systems.

The connection of these reactors in series with capacitors causes a shift of the
resonance frequency of the circuit composed by feeding transformer-reactors
capacitors, so that the resulting self-resonance frequency is well below the line
harmonics foreseen by the ENV 61000-2-2 standard.

Resonance would create undesired effects as overloading of capacitors,


transformer and transmission equipment, amplification of harmonics and voltage
distortion.

The reactors are connected in series with the capacitors to be protected and the
inductive reactance determines the self resonance frequency of the L-C circuit .The
locking factor P% is expressed by the ratio between inductive reactance and
capacitive reactance and it corresponds to the increase of voltage applied to
capacitors, with respect to line voltage .due to circulation of capacitive current in the
reactor.

Basic Calculations Features


1.) Harmonic Load (continuous)
U3=0.5%UR ■long useful life
U5=5.0%UR
U7=5.0%UR ■high linearity
2.) Fundamental Harmonic Load ■low losses & low noise
I1=1.06.IR
(IR=current of the fundamental harmonic) ■High resistance to harmonics
3.) Thermal Rating ■easy mounting
Ith=1.05Irms
4.) Magnetic Rating
Ilin=1.75.L with L(Llin)≥0.95.Ln

Specification

Voltage & frequency. 100V-690V power system,50H(or 60Hz)

output of Kvar 5 to 100Kvar

detuning 7%,5.67%,14% etc.

Harmonic filtering
temperature T40/B,natural cooling ,with temperature protection terminal

impregnation polyester resin, class H

adjustment accuracy L=±3%,U=3KV (winding to core)


& insulation

standards IEC76,VDE0550/0532
r Low Voltage Reactors

Rates:
German Winding Machine
System voltage:400V, 50Hz, AC 400V
Power P% mH IN H L B L1 B1 B2 B3 Weight

in kvar ‫׎‬ (kg)

25 5.5/5.67 1.186 210 230 130 91 62 74 16.5

25 7.0 1.535 36 210 235 135 91 66 78 17.8

25 14 3.238 235 255 150 98 71 83 24.9

50 5.5 0.593 235 255 1 98 70 82 24


50
72 11 150
50 7.0 0.767 235 260 150 98 73 85 25.9

50 14 1.638 260 290 175 118 87 99 36.3

100 5.5/5.67 0.297 265 290 175 98 70 82 39.2

100 7.0 0.384 144 265 295 180 108 79 92 41.9

100 14 0.819 295 325 195 138 92 102 56.6

Mounting Draw:

Excellent design
厂家
GMC Low Voltage Contactors

CAPACITOR CONTACTOR of GMKPGMC can be used in 400-690V, AC,


50-60Hz up to control 60Kvar capacitors, when a capacitance is switched to an
AC system. The result is a resonant circuit damped to a greater or lesser
degree. In addition to the nominal current, the capacitor accepts a transient
current that is a multiple (as more then 200times) of its nominal current. Fast
switching, low-bounce contactors should be used.

Because of the leading contacts, the inrush current spikes (reverse


charging operations) are limited or damped by resistance wires.
These current spikes would lead to welding of the contactor’s main
contacts and they are also harmful for the capacitors. Reduction of the
inrush currents also avoids transients and voltage sags.

Leading contacts with a wiper function are used in these capacitor contactors, is
each leading contact is linked to the contactor yoke by a permanent magnet.
The leading contacts close before the main contacts and open when the main
contacts are with certainty closed. This feature of the capacitor contactors
guarantees effective, stable operation throughout useful life. The single
controlled leading contacts also enhance resistance to soiling during operation.

The capacitor contactors are suitable for direct switching of


low-inductance and low-loss capacitor banks (IEC 831, VDE 0560)
with or without detuning reactors. They feature leading auxiliary
switches and damping resistors to reduce peak inrush to<70* Iin
(inrush current). The capacitor contactors are weld inrush current of
200* Iin. The backup fuses gL (gG) should be scaled for 1.6 to 1.8* Iin
all capacitor contactors come with an auxiliary contact (normally
open).

Features
■Excellent damping of inrush current

■Improved power quality(e.g. avoidance of voltage sags)

■Longer useful life of main contacts of capacitor contactor

■Soft switching of capacitor and thus better useful life

■Enhanced mean lifetime of PFC system

Electric draw of 10-20Kva


■Reduced ohmic losses

■Leading contacts with wiper function

■High quality and long operation life


GMC Low Voltage Contactors

Specification order No. of GMKP GMC-


12/10 18/15 22/18 32/25 40/30 50/40 75/50 85/60
In at 400V (A) 12-15 10-22 22-32 32-40 40-50 50-63 75-80 85-115
Power for Kvar 10-125 15-16 18-20 25 30 40 50 60
assembling 68 x 56(140) x 123 68 x 68(140) 94 x 110(170) x 167
dimension(mm) x130
Terminal Stud dimension M4 M5 M8
Cable size ( mm2) 1.25-5.5mm² 2-14mm² 2-38mm²
Terminal torque (N) 15 26 45
Operation freq. (1/H) 200-240/H
Electric life (million ) 10Kvar-30Kvar: o.2, 40Kvar-60Kvar: o.1
Inrush current (A) 20 In. (protection fuse current rate should be 1.5 In to 2In)
coil voltage (V) AC 220V, (also 36V、110V、220V、380V of AC and DC if needed.
operation Loop working range :85%~110%Us for on,20%~75%Us for off,
auxiliary contacts Two, One of NO and one NC contacts. .
Inrush current Leading contacts with wiper function
ambient <55C,1000M altitude,95% humidity
assembling In addition to be assembled with the bolt also can be with 35mm and
75mm assembling track.

Switching characteristics:
Life curve: excellent switching life
Leading contacts

System voltage

Capacitor voltage

Capacitor current

Mounting draw:

Electric draw of
25-60Kvar
C Controller

Reactive power compensation plants are used to decrease the load of cables and power
distributions caused by inductive currents and to save reactive power costs. The power factor
controller is a main part of such a plant and connects or disconnects capacitor stages
automatically. The power factor controller GMKPc800II is suitable for the use in conventional
or special dynamic reactive power compensation systems, and a mixed operation is possible
as well.

Features

• Micro-processor based.
• Digital power factor display.
• Programmable switching sequence (Optimized) (Auto, Custom or Preset).
• LED indication for individual step.
• Auto / Manual operation.
• Automatic detection of C.T. polarity.
• Automatic detection of C/K value.
• Secondary current / Power Factor info display.
• Voltage / Frequency info display.
• THD / Individual Harmonic info display. (3th to11th harmonics display)
• Alarm output. (THD, Frequency, Under/Over Compensate, Over Voltage).
• Integrated Timer-controlled Exhaust Fan output.
• Programmable over-voltage cut-off.
• Programmable THD cut-off.
• Keypad lock (Software programmable).
• Flush mount
• More than 14 steps

Specification

Power Supply 240 VAC ±10% or other on request

Rated Current (ln) ../5A (same phase with power supply)

Working Current 0.02 - 10A

Operating Frequency 45 ~ 65Hz

Output Relay / Alarm / Fan 5A / 250VAC

Weight ~ 770g

Operating Temperature 0° to +55°C


c Controller

Program table
PROGRAM SEPUENCE

STEP PROGRAM SEPUENCE


c/k 0.02-1.00

P-0 LINEAR Power factor 0.85-0.95

P-1 1:1:1:1:1 Switching 6 program

P-2 1:2:2:2:2 Re-connection time 1-250sec.

P-3 1:1:2:2:2 voltage Off/240-270V

P-4 1:1:1:2:2 THD Off/20-100%

P-5 1:2:4:4:4

P-6 1:1:2:2:4

Control panel

Dimension: 144x144mm; panel


cut-out 136 x 136mm
Electric connection
s Fuse Load Switch

The ability fuse GMKP's fuse for HRC's fuse switch, rising the short circuit
protects using in not having the merit compensating device. It can quickly,
safety and reliably ensures a good protection effect (can have three-phase or
single-phase selection).

Technology characteristics:

The micro switch can be joined in marriage by every switch and be linked with
the monitor system, sending out the switch circumstances signal has the lock to
close or the lead sealing hole. Also avoids the mistaken operation and is easy to
manage the switch.

The fuse is looked at the window and can be slides high and low. A direct
measuring during operating is possible, due using the prepared measuring
point trough the window side. The installation method is single-phase,
three-phase or many kinds of versions four look types.

It is used as a safety device for short circuit protection in PFC system and single
and three phases are available.

Switching characteristic curves:

Electric connection with or without reactor:

Fuse current rate:

Standard (without reactor): If=1.4-1.5 In

With reactor: If=1.6-1.7 In

In: rate current capacitor


s Fuse Load Switch

Rates of 3 Phase:

GMKPs—
DIN43620/11) rate
000 00 1 2 3 4a
4 1250
Rate current Ie A 100 ) 160 250 400 630
16002)
Heating 1250
A 1604) 160 250 400 630
current Ith 16002)
Rate voltage
V 690 690 690 690 690 690
Ue
Rate insurance
V 690 800 800 800 800 800
voltage UI
Tare imp
kV 6 8 8 8 8 8
voltage
Short current
KA 80 50 50 50 50 50
without fuse
Weight without
Kg 0.425 0.65 2.10 3.25 5.30 14.00
fuse
IEC/EN60 Ue=400V AC-22B AC-22B AC-22B AC-22B AC-22B AC-22B
947-3 Ue=690V AC-21B AC-21B AC-21B AC-21B AC-21B AC-21B
Ie= Ith Ue=440V DC-21B DC-21B DC-21B DC-21B DC-21B DC-21B
temperature ℃ -25 to bis+55
Machinery life switch 2000 1600 1000 1000 1000 600
standard VDE0660T107-IEC/EN60947-3
184*260*11 210*290*13 250*270*13 378*340
dimension L.W.D 89*128.5*71 106*186*83
3 9 2 (351)*273

Mounting dimension (mm)

Rate A B C D

Current rating of fuse

Rate voltage ranging current range


Mounting draw:
Automatic Capacitor Banks

Applications:

Automatic power factor correction (PFC) and capacitor banks


Individual solution for fixed power factor correction (e.g. Motor, transformers, lighting
etc.)
Group fixed power factor correction (several equipment connected in a group)
Capacitor banks of tuned and detuned
Harmonic trap applications (e.g. UPS, frequency drives and converters etc.)
Special application such as outdoor mounting, filter model, bushing terminal style etc.

General Technical Data

Over voltages U UN+10%(up to 8h daily)/UN+15%(up to 30 min daily).UN +30%(up to 1 min)/

Over current Imax Min.1.3*IN(in certain cases higher)

Inrush current Is 200 times rated current(other request is available)

Losses (dielectric) ≤0.25W/KVar each capacitors

Capacitance tolerance -5%/+10%

Test voltage terminal to UTT Capacitor 2.15*UN, AC, 10S


terminal
Test voltage terminal to UTC Capacitor Up to UN=≤660V:3000VAC, 10s;above UN=660V:6000 VAC, 10s
case
Life expectancy TLD(CO 100,000 operating hours.(other request is available)
)

Ambient temperature LCT/ -25/D, max, 55℃, with forced cooling conditions higher ambient temperature
category UCT possible.
Cooling Naturally air-cooled (of forced air cooling)

Permissible max Hrel 95%


humidity
Maximum permissible Normal 1000 M above sea level (Max.3000M)
altitude
Reactor Connection 7%,14%,6%,5.67%,12%,13% etc.

Switching type Special capacitor contactor ,fast switching <20ms

Capacitor: Dry technology, overpressure/current disconnector , self-healing,

Safety features Reactor: temperature protection

Cabinet: Fuse protection ,temperature protection

Discharge resistors Internal discharge module design included in delivery, (<75V within 3 min)

Case RAL7031

Main switchgear Main switchgear is available on request

Impregnation Non-PCB, special protection gas or resin.

Dimension FRANKE’s standard or customer’s request

Installation Indoor

Standards IEC60831-1+2, EN60831-1+2, VDE0560-46+47, CE.(UL marking on request)


Automatic Capacitor Banks

General Rates Other rates are available on request

400V, 3Phase, 50/60Hz, without reactors


Power in Capacitor of steps
steps dimension(mm) Order No.
kvar in kvar
50 12.5 - 12.5- 25 3 425×470×25 GMKPB400-3-50

75 12.5-12.5-25-25 4 425×470×25 GMKPB400-3-75

100 12.5-12.5-25-50 4 800×650×280 GMKPB400-3-100

150 25-25-50-50 4 800×650×280 GMKPB400-3-150

200 25-25-50-100 4 1100×760×325 GMKPB400-3-200

250 25-25-50-50-50-50 6 1100×760×325 GMKPB400-3-250

300 25-25-50-100-100 5 1700×600×500 GMKPB400-3-300

350 50-100-100-100 4 1700×600×500 GMKPB400-3-350

500 50 -50-100-100-100-100 6 1700×1200×500 GMKPB400-3-500

400V, 3Phase, 50/60Hz, with 7% reactors


Power in Capacitor of steps
steps dimension(mm) Order No.
kvar in kvar
50 12.5-12.5-25 3 425×470×25 GMKPB400-3-50/7

75 12.5-12.5-25-25 4 425×470×25 GMKPB400-3-75/7

100 12.5-12.5-25-50 4 800×650×280 GMKPB400-3-100/7

150 25-25-50-50 4 800×650×280 GMKPB400-3-150/7

200 25-25-50-100 4 1100×760×325 GMKPB400-3-200/7

250 25-25-50-50-50-50 6 1100×760×325 GMKPB400-3-250/7

300 25-25-50-100-100 5 1700×600×500 GMKPB400-3-300/7

350 50-100-100-100 4 1700×600×500 GMKPB400-3-350/7

500 50-50-100-100-100-100 6 1700×1200×500 GMKPB400-3-500/7

400V, 3Phase, 50/60Hz, with 14% reactors


Power in Capacitor of steps
steps dimension(mm) Order No.
kvar in kvar
50 12.5-12.5-25 3 425×470×25 GMKPB400-3-50/14

75 12.5-12.5-25-25 4 425×470×25 GMKPB400-3-75/14

100 12.5-12.5-25 50 4 800×650×280 GMKPB400-3-100/14

150 25-25-50-50 4 800×650×280 GMKPB400-3-150/14

200 25-25-50-100 4 1100×760×325 GMKPB400-3-200/14

250 25-25-50-50-50-50 6 1100×760×325 GMKPB400-3-250/14

300 25-25-50-100-100 5 1700×600×500 GMKPB400-3-300/14

350 50-100-100-100 4 1700×600×500 GMKPB400-3-350/14

500 50-50-100-100-100-100 6 1700×1200×500 GMKPB400-3-500


Capacitor Racks

Applications:

Rack without reactor Automatic power factor correction (PFC) and capacitor banks
Individual solution for fixed power factor correction (e.g. Motor, transformers, lighting
etc.)
Group fixed power factor correction (several equipment connected in a group)
Capacitor banks of tuned and detuned
Harmonic trap applications (e.g. UPS, frequency drives and converters etc.)
Special application such as outdoor mounting, filter model, bushing terminal style etc.

General Technical Data

Over voltages U UN+10%(up to 8h daily)/UN+15%(up to 30 min daily).UN +30%(up to 1 min)/

Over current Imax Min.1.3*IN(in certain cases higher)

Inrush current Is 200 times rated current(other request is available)

Losses (dielectric) ≤0.25W/KVar each capacitors

Capacitance tolerance -5%/+10%

Test voltage terminal to UTT Capacitor 2.15*UN, AC, 10S


terminal
Test voltage terminal to UTC Capacitor Up to UN=≤660V:3000VAC, 10s;above UN=660V:6000 VAC, 10s
case

Life expectancy TLD(CO) 100,000 operating hours.(other request is available)

Ambient temperature LCT/U -25/D, max, 55℃, with forced cooling conditions higher ambient temperature
category CT possible.
Cooling Naturally air-cooled (of forced air cooling)

Permissible max Hrel 95%


humidity
Maximum permissible Normal 1000 m above sea level (Max.3000M)
altitude

Reactor Connection 7%,14%,6%,5.67%,12%,13% etc.

Switching type Special capacitor contactor ,fast switching <20ms

Capacitor: Dry technology, overpressure/current disconnector , self-healing,


Safety features
Reactor: temperature protection

Discharge resistors Internal discharge module design included in delivery, (<75V within 3 min)
Rack with reactor
Rack Steel rack plate

Main switchgear Main switchgear is available on request

Impregnation Non-PCB, special protection gas or resin.

Dimension FRANKE’s standard or customer’s request

Installation Indoor

Standards IEC60831-1+2, EN60831-1+2, VDE0560-46+47, CE.(UL marking on


request)
Capacitor Racks Capacitor Racks
General Rates

400V, 3Phase, 50/60Hz, without reactors


Power in Capacitor of steps
steps dimension(mm) Order No.
kvar in kvar
12.5 12.5 3 425×470×25 GMKPm400-3-12.5

25 25 4 425×470×25 GMKPm400-3-25

50 25-25 4 800×650×280 GMKPm400-3-50

100 25-25-25-25 4 800×650×280 GMKPm400-3-100

200 50-50-50-50 4 1100×760×325 GMKPm400-3-200

400V, 3Phase, 50/60Hz, with 7% reactors


Power in Capacitor of steps
steps dimension(mm) Order No.
kvar in kvar
12.5 12.5 3 425×470×25 GMKPm400-3-12.5/7

25 25 4 425×470×25 GMKPm400-3-25/7

50 25-25 4 800×650×280 GMKPm400-3-50/7

100 25-25-25-25 4 800×650×280 GMKPm400-3-100/7

200 50-50-50-50 4 1100×760×325 GMKPm400-3-2007

400V, 3Phase, 50/60Hz, with 14% reactors


Power in Capacitor of steps
steps dimension(mm) Order No.
kvar in kvar
12.5 12.5 3 425×470×25 GMKPm400-3-12.5/14

25 25 4 425×470×25 GMKPm400-3-25/14

50 25-25 4 800×650×280 GMKPm400-3-50/14

100 25-25-25-25 4 800×650×280 GMKPm400-3-100/14

200 50-50-50-50 4 1100×760×325 GMKPm400-3-200/14

Other rates are available on request


Active Harmonic Filters

Applications of the filter for:

Automatic power factor correction (PFC) and capacitor banks


Individual solution for fixed power factor correction (e.g. Motor, transformers, lighting
etc.)
Group fixed power factor correction (several equipment connected in a group)
Capacitor banks of tuned and detuned
Harmonic trap applications (e.g. UPS, frequency drives and converters etc.)
Special application such as outdoor mounting, filter model, bushing terminal style etc.

System current before and after the filter

General Technical Data


Over voltages U UN+10%(up to 8h daily)/UN+15%(up to 30 min daily).UN +30%(up to 1 min)/

Life expectancy TLD(CO 100,000 operating hours.(other request is available)


)

Ambient temperature LCT/ -25/D, max, 55℃, with forced cooling conditions higher ambient temperature
category UCT possible.
Cooling fan-cooled system

Permissible max Hrel 95%


humidity
Maximum permissible Normal 1000 M above sea level (Max.3000M)
altitude
responding 1ms

Harmonic scope 2-51th

Safety features over voltage/current/temperature

Discharge resistors Internal discharge module design included in delivery, (<75V within 3 min)

Rack Steel rack plate


Active filter
Main switchgear NH fuse switchgear

Impregnation Non-PCB, special protection gas or resin.

Dimension FRANKE’s standard or customer’s request

Installation Indoor

Standards EN61000-3-4
Active Harmonic Filters

Benefit

Working Principle:
Passive Harmonic Filter (PHF), a harmonic trap which is made of extremely low combination of reactance connected to the
Electronic element power line. Inductor and capacitor, and will trap the specific frequency spectrum harmonic current. Active Harmonic Filter
(AHF) It is a harmonic compensator, which is made of IGBT component and is actively monitor the harmonic spectrum and
amplitude in the power line. A reverse matching harmonic current will be injected to attenuate the active harmonic current
becoming sinusoidal waveform.

The ability of different Harmonics spectrum:


PHF, Individual harmonic LC trap is designed for different harmonic spectrum. AHF, High performance harmonic cancellation
from 2nd to 51st harmonic spectrum in a single Active Power Harmonic Filter.

Impact in variation of line impedance:


PHF, It has potential risk in resonance when line impedance varying within the power network (system). AHF, No impact by
changes of line impedance within the system.

Impact in power frequency variation:


PHF, Harmonic spectrum shifted from the designed harmonic trap, and eventually decreases the attenuation performance.
AHF, No impact in frequency variation, the Active Power Harmonic Filter instantly provides correct harmonic compensating
current even when frequency level changes.

Impact in excessive load increase:


PHF, Could lead to harmonic break down due to overload loading the LC harmonic filter. AHF, Active Power Harmonic Filter
will not breakdown, if overloading occurs. The current limitation protection in Active Harmonic Filter will absorb maximum
harmonic current and mains will take care the balance harmonic current.

Physical size:
PHF, Bigger (3) Big in size, AHF, Smaller (1), Compact in size and can be wall mounted in some power ratings. 100% load,
Ithd[8%,50% % load Ithd[14%10% load, Ithd[17% All be keep in the Ithd < 5%

General Rates Other rates are available on request

400V, 3Phase, 50/60Hz, 3P4L


Power in Responding
Rate current(A) Harmonics scope Order No.
Current time(ms)
25 25 1 2-51th GMKPAHFA10-25

50 50 1 2-51th GMKPAHFA10-50

100 100 1 2-51th GMKPAHFA10-100

150 150 1 2-51th GMKPAHFA10-150

200 200 1 2-51th GMKPAHFA10-200

400V, 3Phase, 50/60Hz, 3P3L


Power in Responding
Rate current(A) Harmonics scope Order No.
Current time(ms)
25 25 1 2-51th GMKPAHFA10-25/

Display harmonics 2-51th 50 50 1 2-51th GMKPAHFA10-50/

100 100 1 2-51th GMKPAHFA10-100/

150 150 1 2-51th GMKPAHFA10-150/

200 200 1 2-51th GMKPAHFA10-200/


References

FRANKE GMKP has founded successful corporation with famous brands and manufacturer
all over the world. Because of FRANKE GMKP does strongly work to keep and improve a
German Quality level, we were selected by international renowned companies (like ABB,
Siemens, and LS) for using our products.

Beside the world famous brands, FRANKE GMKP is partner of major projects like (Olympic
projects, diversion, DC input Electricity, etc.).Moreover FRANKE is supplier of many famous
foreign brand-capacitor manufacturers for their (OEM) production of capacitors. In addition to our
capacitor manufacturing FRANKE GMKP ENERGY CONTROL provides a wide range of products
for power factor correction (PFC), such like:

MV Capacitors MV Dry &Air Coil reactors Capacitor Banks of: automatic, Pole mounted and open Racks

FRANKE GMKP LTD.


Berlin,Frankfurt,Germany Tel: 0049 30200033043 Email:info@frankegmkp.com
C1607 Software Park, National Hi-Tech Industry Development Area, Wuxi.
Tel 0086 510 85211911, Fax:0086 510 85215070 Email:info@frankeenergy.com
Http://www.frankegmkp.com