THERMAL IMAGE
Application Measuring inputs
The relay type NA20 is typically used in HV, MV and LV radial Three phase current inputs and one residual current input, with
networks as feeder or power transformer protection. nominal currents independently selectable at 1 A or 5 A through
In solidly grounded systems the residual overcurrent protection DIP-switches.
can be used on feeders of any length, while in ungrounded or
Petersen coil and/or resistance grounded systems, the residual Firmware updating
overcurrent protection can be used on feeders of small length in The use of flash memory units allows on-site firmware updating.
order to avoid unwanted trippings due to the capacitive current
contribution of the feeder on external ground fault. Construction
Beside to the phase and residual overcurrent protection, the fol- According to the hardware configurations, the NA20 protection
lowing protective functions are provided: relay can be shipped in various case styles depending on the
• Thermal image protection of lines and power transformers. required mounting options (flush, projecting mounting, rack or
• Undercurrent protection for monitoring of CB opening. with separate operator panel).
• Negative sequence protection against asymmetrical short cir-
cuits and unbalance loads.
• I2/I1 protection against phase interruption under low-load con-
dition.
Protective functions
37 Undercurrent
46 Negative-sequence overcurrent
49 Thermal image
50/51 Phase overcurrent
50N/51N Residual overcurrent
I 2/I 1 Phase interruption under low-load condition
BF Circuit breaker failure
52
74TCS
37 46 49
50N/51N COMMUNICATION
- RS232
Control functions - Modbus RS485
& - Modbus TCP/IP
Logic selectivity - IEC 870-5-103/DNP3
Binary inputs
Two or five binary inputs are available with programmable active
state (active-ON/active-OFF) and programmable timer (active to
OFF/ON or ON/OFF transitions). Communication
Several presettable functions can be associated to each input. Multiple communication interfaces are implemented:
• One RS232 local communication front-end interface for com-
munication with ThySetter setup software.
Blocking input/outputs
• Two back-end interfaces for communication with remote mon-
One output blocking circuit and one input blocking circuit are
itoring and control systems by:
provided.
- RS485 port using ModBus® RTU, IEC 60870-5-103 or DNP3
The output blocking circuits of one or several Pro_N relays,
protocol,
shunted together, must be connected to the input blocking cir-
- Ethernet port (RJ45 or optical fiber) using ModBus/TCP pro-
cuit of the protection relay, which is installed upwards in the
tocol.
electric plant. The output circuit works as a simple contact,
whose condition is detected by the input circuit of the upwards
protection relay.
Programming and settings
All relay programming and adjustment operations may be per-
For long distances, when high insulation and high EMC immunity
formed through MMI (Keyboard and display) or using a Personal
is essential, a suitable pilot wire to fiber optic converter (BFO)
Computer with the aid of the ThySetter software.
is available.
The same PC setup software is required to set, monitor and con-
figure all Pro_N devices.
Output relays Full access to the available data is provided:
Six output relays are available (two changeover, three make and • Read status and measures.
one break contacts); each relay may be individually programmed • Read/edit settings (on-line or off-line edit).
as normal state (normally energized, de-energized or pulse) and Two session level (User or Administrator) with password for sen-
reset mode (manual or automatic). sible data access are provided.
ThySetter
TRIP I>>
BLIN1
BLOUT1
BLIN1
TRIP I>> Block2 IPh TRIP I>>
BLIN1
BLOUT1
TRIP I>>
Any device
Logic selectivity
Oscillography (DFR)
L1
L2
L3
NA20
K1 A3
A4
A5
K2 A6
A7
P1 C1
A8
S1
I L1 OUTPUT RELAYS
S2 C2 K3 A9
P2
C3 A10
K4
CURRENT INPUTS
I L2
C4 A11
C5 K5 A12
I L3
C6 K6 A13
P1 C7 A14
S1
IE
S2 C8
P2
F1
F2
A19
IN1 F3
RS485
A20 F4
B-
A21 Supervision
IN2 A+ F5
A22 unit
BINARY INPUTS
B1
IN3
B2
B3
IN4
ETHERNET
B4
B5 D1
IN5
HUB
B6
54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28
THYBUS
A1 ≅ E1
UAUX
A2
OUTPUT INPUT
RUN
BUS
ON
MRI
4 RELAYS + 8 BINARY INPUTS MODULE
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
BLOCK OUT
BLOCK IN
BLOUT-
A17 A15
BLOUT+
A18 A16
FRONT PANEL
RS232
D1 D1
A1 A1
A2 A2
C1 C2 C1 C2
ø 4.5 A3
A4 RX
F1
F2
A3
A4 RX
F1
F2
A5 F3 A5 F3
A6 TX F4 A6 TX F4
A7 F5 A7 F5
A8 C3 C4 A8 C3 C4
A9 B1 A9 B1
A10 B2 A10 B2
177
171
149
200
168
A11 B3 A11 B3
A12 B4 A12 B4
ON 1 2 3 4 5 START ON 1 2 3 4 5 START
A13 B5 A13 B5
80
A17 A17
A18 A18
A19 A19
A20 C7 C8 A20 C7 C8
A21 A21
A22 A22
31
E1 E1
20
FLUSH MOUNTING PROJECTING MOUNTING FLUSH MOUNTING PROJECTING MOUNTING
(Separate operator panel)
SIDE VIEWS
212.5 275
25 15
205 30 5 30 ø 4.5
170
161
101.6
154
Headquarters: 20139 Milano - Piazza Mistral, 7 - Tel. +39 02 574 957 01 ra - Fax +39 02 574 037 63
Factory: 35127 Padova - Z.I. Sud - Via dell’Artigianato, 48 - Tel. +39 049 894 770 1 ra - Fax +39 049 870 139 0