You are on page 1of 6

INSTRUCTION SHEET IS - RLV5006

STYLE NUMBER: RLV5006MA


6 CORPORATE PARKWAY
GOOSE CREEK, SC. 29445
www. quoizel . c om

PACKAGE CONTENTS ISSUED 11-2008 Revised 2008 - 12 - 22

Part Description Quantity


A Crossbar 1pc
B Green Ground Screw 1pc J
A
C Hex Nut 2pcs
D Nipple 1pc
K
E Lock Washer 2pcs
Canopy Chain Loop 1pc B L
F
C
G Canopy Lock Ring 1pc
Fixture Chain 1pc D
H
I Ceiling Canopy 1pc E
J Fixture Loop 1pc M
F
K Knurled Nut 1pc
L Band A (with 24 loops on the bottom) 1pc N
Band B with Sockets 1pc G
M
O
N Band C(with 24 loops on the top) 1pc
H
O Finial 1pc P
P Candle Cover 6pcs
Q Jewelry Plier 1pc I
R Long Stem 1pc Q
S Short Stem 1pc
Bead Kit (85006BZKIT1)
A)- Bead String A 24 pieces R
T 1pc
B)- Bead String B 24 pieces
C)- Bead 24 pieces S

T:
A)

B) C)

! WARNINGS AND CAUTIONS


WARNING:
● Before beginning the installation, turn off electricity at the circuit breaker box or the main fuse box by
switching off the circuit breaker or removing the fuse.
CAUTIONS:
● These instructions are provided for your safety. It is very important that they are read completely before
the installation of your fixture. We strongly recommend that a professional electrician install the fixture.
● Disconnect fixture from the power source before replacing the bulb(s), making sure the bulb(s) had
sufficient time to cool down. DO NOT subject the lamp to any shock while lit as shattering of lamp may
result.

PREPARATION
● Before beginning installation of product, make sure all parts are present. Compare parts with package
contents list and diagram above. If any part is missing or damaged, do not attempt to assemble, install or
operate the product. Contact customer service for replacement part.
● Estimated Assembly Time: 45 - 60 minutes
● Tools Required for Assembly (not included): Flathead screwdriver , Phillips screwdriver, pliers, electrical
tape, wire cutters, safety glasses &6, 60 Watt, Candelabra Base Bulbs.
● Helpful Tools (not included): Wire Strippers.

1 OF 6
INSTALLATION INSTRUCTIONS STYLE NUMBER: RLV5006MA

STEP 1:
a. Thread the end of the Long Stem onto the nipple on the
center of the Junction Box as shown. Hand tighten utnil Long Stem
snug. Junction Box
Ring B with Sockets

STEP 2:
a. Locate the Band A (Top ring with 12 loops, bottom ring with Fig . 1
24 loops and 12 wooden balls) over the top end of the Long
Stem. (Refer to Fig . 2 ) Line up Spokes on Band A and Fixture Loop
B as shown in the illustration . Secure by threading
Knureld Nut onto the stem and hand tighten until snug.
b. Thread the Fixture Loop onto the top end of the Long Stem Knurled Nut
and hand tighten until snug.
Band A

Long Stem

Band A:
Fig . 2
Spoke

Top View
Line up the
Spokes as shown
during assembly . Front View

Band B: Top View

Spoke

Front View

2 OF 6
INSTALLATION INSTRUCTIONS STYLE NUMBER: RLV5006MA

STEP 3:
a. Thread the top end of the Short Stem onto the nipple on the Junction Box
bottom center of the Junction Box as shown. Hand tighten
until snug.

Band B

Short Stem

STEP 4: Fig . 1
a. Locate the Band C(Top ring with 24 loops, bottom ring with
24 loops and 12 wooden balls) over the end of the Short
Stem. (Refer to Fig . 2 ) Please make sure the Band A, B Short Stem
and C are lined up correctly as shown in the illustration.
b. Secure the Band C by threading the Finial onto the end of Band C
the Short Stem. Hand tighten until snug.

Finial

Fig . 2 Band A:
Spoke
Line up the
Spokes as shown Bottom
during assembly . View

Front View

Band B:
Top View

Spoke

Front View

Band C:
Spoke

Bottom View

Front
View

3 OF 6
INSTALLATION INSTRUCTIONS STYLE NUMBER: RLV5006MA

STEP 5 :
a. Secure the Crossbar onto the Outlet Box with Outlet
Box Screws . Tighten until snug. Outlet Box

Crossbar

Outlet Box
Screw

STEP 6:
* Plier is required on this step.
a . Thread one Hex Nut onto top end of the Nipple .
b . Place one Lock Washer over the top end of the Nipple
and then thread the Nipple into the center lock hole of
the Crossbar . Lock Washer
c . Us ing plier , thread the Hex Nut against the c rossbar Crossbar
Hex Nut
and hand tighten until snug .
d . Thread another Hex Nut onto the bottom end of the
Nipple .
Nipple

Hex Nut

STEP 7 :
a . Adjust the Fixture Chain to your desired length by
removing the links if needed .
* Please note that depends on chain material thickness ,
Nipple
you might be required to use chain pliers to spread links
open . Hex Nut
b . Pull the supply wires through the Fixture Chain alternating
links. And then pull the wires through the following Lock Washer
components in turn:
Canopy Lock Ring, Ceiling Canopy, Canopy Chain Loop, Canopy Chain
Lock Washer , and Nipple . Loop
c . Place Lock Washer over the end of the Nipple and thread
the Canopy Chain Loop onto the end of the Nipple .
d . Using plier , thread the Hex Nut against the Canopy Chain Ceiling
Loop and tighten until snug . Canopy
e . Attach one end of the Fixture Chain onto the Fixture Loop
and attach the another end of the chain onto the Canopy
Chain Loop .
f . Refer to Step 8 - Wire Connections to connect wires. Fixture Chain
g . Push the Ceiling Canopy upward over the Outlet Box .
h . Thread the Canopy Lock Ring onto the Canopy Chain Loop
and tighten until snug to secure the Ceiling Canopy .
Canopy Lock
Ring

Fixture Loop

4 OF 6
INSTALLATION INSTRUCTIONS STYLE NUMBER: RLV5006MA

STEP 8 :
* Use Wire Connectors ( not supplied ) to connect the wires .
WHITE WIRE WHITE OR RIBBED
a . Connect the House Ground Wire to the Fixture Ground
Wire. FROM HOUSE FROM FIXTURE
b . Connect the House White Wire to the Fixture Supply Wire
BLACK( OR RED )WIRE BLACK OR SMOOTH
( White or Ribbed Side ) .
c . Connect the House Black ( or Red ) Wire to the Fixture FROM HOUSE FROM FIXTURE
Supply Wire ( Black or Smooth Side) .
d . Wrap each connection with approved electrical tape and GROUND WIRE GROUND WIRE
carefully stuff all of the connected wires into the Outlet Box . FROM HOUSE FROM FIXTURE

STEP 9 : Fig . 1
a. Align the Spokes of Band A , B &C according to BEAD
STRINGS ALIGNMENT drawing .
b. Begin by attaching one end of Bead String A to 2nd loop Band A
from Socket on top ring of Band B .
c. Attach the other end of Bead String A to corresponding Spoke
position on bottom ring of Band A .
d. Repeat this procedure attaching one end of Bead String
A on every fourth loop ( skip 2 loops) around the
circumference of the top ring of Band B and the other Bead String A
end of the Bead String on every loop on the bottom ring
of Band A .
e. Attach one end of Bead String B to 2nd loop from socket Socket
on bottom ring of Band B . 2nd pinhole
f. Attach other end of Bead String B to corresponding loop from Socket

on top of Band C . Start with


2nd loop
g. Repeat this procedure attaching one end of Bead String from Socket
B on every fourth loop ( skip two loops) around the
circumference of the bottom ring of Band B and the Band B
other end of the string on every loop on the top of Band
C. Start with 2nd
loop from t he
h . Attach Bead C to every loop on the bottom of Band C . socket
i . Bead Strings A & B should hang parallel to the center Spoke
tube of the fixture . If the strings are not parallel , Bead
slightly rotate Band A or C to obtain parallel alignment . String B

Band C

Spoke Bead C

Bead Strings Alignment


2nd Hooks from
the Socket
Socket

Bead B

5 OF 6
INSTALLATION INSTRUCTIONS STYLE NUMBER: RLV5006MA

STEP 10 :
a . Place Candle Covers over Sockets as shown in the Candle Cover
Socket
illustration.

STEP 11 :
a. Install correct Bulbs referring to fixture markings and/or labels for maximum wattage.

Your installation is completed now. Restore electricity. Retain this sheet for future reference.

Photograph

6 OF 6

You might also like