You are on page 1of 1

POP1 Switch Connection & Configuration

SFP's Connection (Gb/s)

Extreme Configuration (STAR Connection)

Would you like to disable Telnet? [y/N]: NO


Would you like to disable SNMP? [y/N]: NO
Would you like unconfigured ports to be turned off by default? [y/N]: YES
Bearer & Management Configuration
X250e-240# configure account admin
Password : M0t0r0la
Retype the Password: M0t0r0la
X250e-240# create vlan BV_RPOP1_Cluster_1

X250e-240# configure BV_RPOP1_Cluster_1 tag 1300

X250e-240# create vlan MGMT_SW


X250e-240# create vlan MGMT_WIMAX
X250e-240# create vlan MGMT_MW
X250e-240# configure vlan MGMT_WIMAX tag 1800
X250e-240# configure vlan MGMT_SW tag 2001
X250e-240# configure vlan MGMT_MW tag 2011
X250e-240# configure vlan BV_RPOP1_Cluster_1 add ports 1-12,21 tagged

X250e-240# configure vlan MGMT_SW add ports all tagged ; Ports that are connecting to a certain Switches.
X250e-240# configure vlan MGMT_WIMAX add ports 1-24 tagged
X250e-240# configure vlan default delete port 19
X250e-240# configure vlan MGMT_MW add port 19
X250e-240# enable ports 1-22
X250e-240# enable jumbo-frame ports all
X250e-240# disable stpd
X250e-240# configure ports 1-24 auto on
X250e-240# configure ports 1-20 auto-polarity on
X250e-240# configure vlan MGMT_SW ipaddress 10.200.96.11/24
X250e-240# configure iproute add default 10.200.96.1 vr vr-default
X250e-240# Show vlan BV_RPOP1_Cluster_1 ;Check over the Active ports
X250e-240# Show vlan BV_RPOP1_Cluster_2 ;Check over the Active ports
X250e-240# Show vlan MGMT_WIMAX
X250e-240# Show vlan MGMT_SW
X250e-240# enable vlan BV_RPOP1_Cluster_1
X250e-240# enable vlan BV_RPOP1_Cluster_2
X250e-240# enable vlan MGMT_SW
X250e-240# enable vlan MGMT_WIMAX
SNMP Configuration
X250e-240# configure SNMP Sysname RPOP1_SW_01
RPOP1_SW_01# configure SNMP SysContact contactMoto
RPOP1_SW_01# configure SNMP SysLocation "Site_Location"
RPOP1_SW_01# Configure SNMP delete community readwrite private
RPOP1_SW_01# configure SNMP delete community readonly public
RPOP1_SW_01# configure SNMP add community readwrite motorwcom
RPOP1_SW_01# configure SNMP add community readonly motorocom
RPOP1_SW_01# configure SNMP add trapreceiver 172.16.89.8 community motorwcom
RPOP1_SW_01# configure SNMP add trapreceiver 172.17.89.8 community motorwcom
RPOP1_SW_01# enable SNMP access
RPOP1_SW_01# enable SNMP traps
NTP Configuration
RPOP1_SW_01# configure timezone +180 noautost
RPOP1_SW_01# configure sntp-client update-interval 3600
RPOP1_SW_01# enable sntp-client
RPOP1_SW_01# configure sntp-client primary 172.16.89.4
RPOP1_SW_01# configure sntp-client secondary 172.17.89.4
QOS Configuration

RPOP1_SW_01# Save configuration


RPOP1_SW_01# exit